RC7586-MIB: View SNMP OID List / Download MIB
VENDOR: CODAN LIMITED
Home | MIB: RC7586-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
rc7586MIB | 1.3.6.1.4.1.23304.2.2 |
The Structure of Management Information for the Codan enterprise. Copyright(c) 2009 All rights reserved |
||
buc1 | 1.3.6.1.4.1.23304.2.2.1 | |||
buc1Configuration | 1.3.6.1.4.1.23304.2.2.1.1 | |||
buc1TxSettings | 1.3.6.1.4.1.23304.2.2.1.1.1 | |||
buc1TxOn | 1.3.6.1.4.1.23304.2.2.1.1.1.1 | integer | read-write |
Sets Tx on/off. Respond -1 if buc1 not connected. |
buc1TxDefault | 1.3.6.1.4.1.23304.2.2.1.1.1.2 | integer | read-write |
Sets Tx default 1-last 0-off. Respond -1 if buc1 not connected. |
buc1TxAttenuator | 1.3.6.1.4.1.23304.2.2.1.1.1.3 | integer | read-write |
Sets/Gets Tx attenuation value in 1dBm steps. Respond -1 if buc1 not connected. |
buc1PktProtocol | 1.3.6.1.4.1.23304.2.2.1.1.2 | |||
buc1Protocol | 1.3.6.1.4.1.23304.2.2.1.1.2.1 | integer | read-write |
Sets/Gets packet protocol 0 - ASCII, 1 - CODAN, 2 - SAbus, 3 - Comstream, 4 - NDSatcom. Respond -1 if buc1 not connected. |
buc1Address | 1.3.6.1.4.1.23304.2.2.1.1.2.2 | integer | read-write |
Sets/Gets packet address: 0-31 NDSatcom ...Respond -1 if buc1 not connected. |
buc1RCSetting | 1.3.6.1.4.1.23304.2.2.1.1.3 | |||
buc1Mode | 1.3.6.1.4.1.23304.2.2.1.1.3.1 | integer | read-write |
Sets/Gets redundancy mode 0-none, 1-warm, 2-hot. Respond -1 if buc1 not connected. |
buc1OnLine | 1.3.6.1.4.1.23304.2.2.1.1.3.2 | truthvalue | read-write |
Sets/Gets redundancy mode on on/off line state. Respond -1 if buc1 not connected. |
buc1Freqs | 1.3.6.1.4.1.23304.2.2.1.1.4 | |||
buc1RFFreq | 1.3.6.1.4.1.23304.2.2.1.1.4.1 | integer | read-write |
Sets/Gets the RBUC RF frequency. Respond -1 if buc1 not connected. |
buc1IFFreq | 1.3.6.1.4.1.23304.2.2.1.1.4.2 | integer | read-write |
Sets/Gets the RBUC IF frequency. Respond -1 if buc1 not connected. |
buc1LOFreq | 1.3.6.1.4.1.23304.2.2.1.1.4.3 | integer | read-write |
Sets/Gets the RBUC LO frequency. Respond -1 if buc1 not connected. |
buc1Misc | 1.3.6.1.4.1.23304.2.2.1.1.5 | |||
buc1SerIf | 1.3.6.1.4.1.23304.2.2.1.1.5.1 | displaystring | read-write |
Sets/Gets serial interface - rate, length, parity, stop, terminate RS422/485. **** No respond - message if buc1 not connected. |
buc1PwrAlarmThresh | 1.3.6.1.4.1.23304.2.2.1.1.5.2 | displaystring | read-write |
Sets/Gets power alarm threshold. **** No respond - message if buc1 not connected. |
buc1BurstPwrThresh | 1.3.6.1.4.1.23304.2.2.1.1.5.3 | displaystring | read-write |
Sets/Gets burst power threshold. **** No respond - message if buc1 not connected. |
buc1RefSource | 1.3.6.1.4.1.23304.2.2.1.1.5.4 | displaystring | read-write |
Sets/Gets reference source 0-external, 1-internal (Only for RBUC). **** No respond - message if buc1 not connected. |
buc1LEDState | 1.3.6.1.4.1.23304.2.2.1.1.5.5 | displaystring | read-write |
Sets/Gets LEDs status on/off (Only for RBUC). **** No respond - message if buc1 not connected. |
buc1Status | 1.3.6.1.4.1.23304.2.2.1.2 | |||
buc1PaStatus | 1.3.6.1.4.1.23304.2.2.1.2.1 | integer | read-only |
Gets to 1 when PA is on. Respond -1 if buc1 not connected. |
buc1TxPower | 1.3.6.1.4.1.23304.2.2.1.2.2 | displaystring | read-only |
Gets Tx power format x.x dB. **** No respond - message if buc1 not connected. |
buc1TxBurstPower | 1.3.6.1.4.1.23304.2.2.1.2.3 | displaystring | read-only |
Gets Tx power. Format is x.x,y.y,z.z, where x.x is current burst power, y.y is min and z.z is max burts power. **** No respond - message if buc1 not connected. |
buc1Faults | 1.3.6.1.4.1.23304.2.2.1.2.4 | integer | read-only |
Gets the current fault status. Format - Bit0 PA fault, Bit1 Fan fault, Bit2 Power fault, Bit3 Temp fault, Bit4 10MHz fault, Bit5 Internal fault Bit6 LNB fault, Bit7 Red'cy Cont fault. Respond -1 if buc2 not connected. |
buc1LatchedFaults | 1.3.6.1.4.1.23304.2.2.1.2.5 | integer | read-only |
Gets the current latched faults. Format is same as Faults. Respond -1 if buc2 not connected. |
buc1Temperature | 1.3.6.1.4.1.23304.2.2.1.2.6 | displaystring | read-only |
Gets the BUC temperature. Format is x.x. **** No respond - message if buc1 not connected. |
buc1MinMaxTemperature | 1.3.6.1.4.1.23304.2.2.1.2.7 | displaystring | read-only |
Gets the BUC temperature. Format is x.x,y.y where x.x is max and y.y is min temperature. **** No respond - message if buc1 not connected. |
buc1SystemSetting | 1.3.6.1.4.1.23304.2.2.1.2.8 | integer | read-only |
Gets the current system status. Format is Bit0 - PA state, Bit1 - RS232 Tx, Bit2 - FSK Tx, Bit3 - RS485 Tx Bit4 - Redundancy mode, Bit5 - Online, Bit6..Bit7 - Redundancy cold or hot mode, Bit8 - HTTP Tx, Bit9 - TELNET Tx, Bit10 - SNMP Tx. Respond -1 if buc1 not connected. |
buc1SystemPoll | 1.3.6.1.4.1.23304.2.2.1.2.9 | integer | read-only |
Gets the system poll status. Format is Bit0 - Fault, Bit1 - System change. Respond -1 if buc1 not connected. |
buc1DeviceType | 1.3.6.1.4.1.23304.2.2.1.2.10 | displaystring | read-only |
Gets the device type. Format is X,Y where X is the model and Y is software version. **** No respond - message if buc1 not connected. |
buc1Gateway | 1.3.6.1.4.1.23304.2.2.1.2.11 | displaystring | read-only |
Gets the BUC gateway address (Only for RBUC). **** No respond - message if buc1 not connected. |
buc1IpAddress | 1.3.6.1.4.1.23304.2.2.1.2.12 | displaystring | read-only |
Gets the BUC IP address (Only for RBUC). **** No respond - message if buc1 not connected. |
buc1MACAddress | 1.3.6.1.4.1.23304.2.2.1.2.13 | displaystring | read-only |
Gets the BUC MAC address (Only for RBUC). **** No respond - message if buc1 not connected. |
buc1Netmask | 1.3.6.1.4.1.23304.2.2.1.2.14 | displaystring | read-only |
Gets the BUC netmask (Only for RBUC). **** No respond - message if buc1 not connected. |
buc1RefPower | 1.3.6.1.4.1.23304.2.2.1.2.15 | displaystring | read-only |
Gets the BUC reference power. **** No respond - message if buc1 not connected. |
buc1Config | 1.3.6.1.4.1.23304.2.2.1.2.16 | displaystring | read-only |
Gets the BUC configuration. **** No respond - message if buc1 not connected. |
buc1BuildStandard | 1.3.6.1.4.1.23304.2.2.1.2.17 | displaystring | read-only |
Gets the BUC build standard. **** No respond - message if buc1 not connected. |
buc1Info | 1.3.6.1.4.1.23304.2.2.1.3 | |||
buc1IdInfo | 1.3.6.1.4.1.23304.2.2.1.3.1 | displaystring | read-only |
Gets the module firmware revision, serial number and model. This string will have a zero length if the revision is unknown. **** No respond - message if buc1 not connected. |
buc1Limits | 1.3.6.1.4.1.23304.2.2.1.3.2 | displaystring | read-only |
Gets the limit data for the BUC. Format is: Power meter MIN/MAX , IF,RF and LO frequencies. This string will have a zero length if the revision is unknown. **** No respond - message if buc1 not connected. |
buc1PktProtocolsInfo | 1.3.6.1.4.1.23304.2.2.1.3.3 | displaystring | read-only |
Gets supported packet protocols and the corresponding address ranges. **** No respond - message if buc1 not connected. |
buc2 | 1.3.6.1.4.1.23304.2.2.2 | |||
buc2Configuration | 1.3.6.1.4.1.23304.2.2.2.1 | |||
buc2TxSettings | 1.3.6.1.4.1.23304.2.2.2.1.1 | |||
buc2TxOn | 1.3.6.1.4.1.23304.2.2.2.1.1.1 | integer | read-write |
Sets Tx on/off. Respond -1 if buc2 not connected. |
buc2TxDefault | 1.3.6.1.4.1.23304.2.2.2.1.1.2 | integer | read-write |
Sets Tx default 1-last 0-off. Respond -1 if buc2 not connected. |
buc2TxAttenuator | 1.3.6.1.4.1.23304.2.2.2.1.1.3 | integer | read-write |
Sets/Gets Tx attenuation value in 1dBm steps. Respond -1 if buc2 not connected. |
buc2PktProtocol | 1.3.6.1.4.1.23304.2.2.2.1.2 | |||
buc2Protocol | 1.3.6.1.4.1.23304.2.2.2.1.2.1 | integer | read-write |
Sets/Gets packet protocol 0 - ASCII, 1 - CODAN, 2 - SAbus, 3 - Comstream, 4 - NDSatcom. Respond -1 if buc2 not connected. |
buc2Address | 1.3.6.1.4.1.23304.2.2.2.1.2.2 | integer | read-write |
Sets/Gets packet address: 0-31 NDSatcom ...Respond -1 if buc2 not connected. |
buc2RCSetting | 1.3.6.1.4.1.23304.2.2.2.1.3 | |||
buc2Mode | 1.3.6.1.4.1.23304.2.2.2.1.3.1 | integer | read-write |
Sets/Gets redundancy mode 0-none, 1-warm, 2-hot. Respond -1 if buc2 not connected. |
buc2OnLine | 1.3.6.1.4.1.23304.2.2.2.1.3.2 | truthvalue | read-write |
Sets/Gets redundancy mode on on/off line state. Respond -1 if buc2 not connected. |
buc2Freqs | 1.3.6.1.4.1.23304.2.2.2.1.4 | |||
buc2RFFreq | 1.3.6.1.4.1.23304.2.2.2.1.4.1 | integer | read-write |
Sets/Gets the RBUC RF frequency. Respond -1 if buc2 not connected. |
buc2IFFreq | 1.3.6.1.4.1.23304.2.2.2.1.4.2 | integer | read-write |
Sets/Gets the RBUC IF frequency. Respond -1 if buc2 not connected. |
buc2LOFreq | 1.3.6.1.4.1.23304.2.2.2.1.4.3 | integer | read-write |
Sets/Gets the RBUC LO frequency. Respond -1 if buc2 not connected. |
buc2Misc | 1.3.6.1.4.1.23304.2.2.2.1.5 | |||
buc2SerIf | 1.3.6.1.4.1.23304.2.2.2.1.5.1 | displaystring | read-write |
Sets/Gets serial interface - rate, length, parity, stop, terminate RS422/485. **** No respond - message if buc2 not connected. |
buc2PwrAlarmThresh | 1.3.6.1.4.1.23304.2.2.2.1.5.2 | displaystring | read-write |
Sets/Gets power alarm threshold. **** No respond - message if buc2 not connected. |
buc2BurstPwrThresh | 1.3.6.1.4.1.23304.2.2.2.1.5.3 | displaystring | read-write |
Sets/Gets burst power threshold. **** No respond - message if buc2 not connected. |
buc2RefSource | 1.3.6.1.4.1.23304.2.2.2.1.5.4 | displaystring | read-write |
Sets/Gets reference source 0-external, 1-internal (Only for RBUC). **** No respond - message if buc2 not connected. |
buc2LEDState | 1.3.6.1.4.1.23304.2.2.2.1.5.5 | displaystring | read-write |
Sets/Gets LEDs status on/off (Only for RBUC). **** No respond - message if buc2 not connected. |
buc2Status | 1.3.6.1.4.1.23304.2.2.2.2 | |||
buc2PaStatus | 1.3.6.1.4.1.23304.2.2.2.2.1 | integer | read-only |
Gets to 1 when PA is on. Respond -1 if buc2 not connected. |
buc2TxPower | 1.3.6.1.4.1.23304.2.2.2.2.2 | displaystring | read-only |
Gets Tx power format x.x dB. **** No respond - message if buc2 not connected. |
buc2TxBurstPower | 1.3.6.1.4.1.23304.2.2.2.2.3 | displaystring | read-only |
Gets Tx power. Format is x.x,y.y,z.z, where x.x is current burst power, y.y is min and z.z is max burts power. **** No respond - message if buc2 not connected. |
buc2Faults | 1.3.6.1.4.1.23304.2.2.2.2.4 | integer | read-only |
Gets the current fault status. Format - Bit0 PA fault, Bit1 Fan fault, Bit2 Power fault, Bit3 Temp fault, Bit4 10MHz fault, Bit5 Internal fault Bit6 LNB fault, Bit7 Red'cy Cont fault. Respond -1 if buc2 not connected. |
buc2LatchedFaults | 1.3.6.1.4.1.23304.2.2.2.2.5 | integer | read-only |
Gets the current latched faults. Format is same as Faults. Respond -1 if buc2 not connected. |
buc2Temperature | 1.3.6.1.4.1.23304.2.2.2.2.6 | displaystring | read-only |
Gets the BUC temperature. Format is x.x. **** No respond - message if buc2 not connected. |
buc2MinMaxTemperature | 1.3.6.1.4.1.23304.2.2.2.2.7 | displaystring | read-only |
Gets the BUC temperature. Format is x.x,y.y where x.x is max and y.y is min temperature. **** No respond - message if buc2 not connected. |
buc2SystemSetting | 1.3.6.1.4.1.23304.2.2.2.2.8 | integer | read-only |
Gets the current system status. Format is Bit0 - PA state, Bit1 - RS232 Tx, Bit2 - FSK Tx, Bit3 - RS485 Tx Bit4 - Redundancy mode, Bit5 - Online, Bit6..Bit7 - Redundancy cold or hot mode, Bit8 - HTTP Tx, Bit9 - TELNET Tx, Bit10 - SNMP Tx. Respond -1 if buc2 not connected. |
buc2SystemPoll | 1.3.6.1.4.1.23304.2.2.2.2.9 | integer | read-only |
Gets the system poll status. Format is Bit0 - Fault, Bit1 - System change. Respond -1 if buc2 not connected. |
buc2DeviceType | 1.3.6.1.4.1.23304.2.2.2.2.10 | displaystring | read-only |
Gets the device type. Format is X,Y where X is the model and Y is software version. **** No respond - message if buc2 not connected. |
buc2Gateway | 1.3.6.1.4.1.23304.2.2.2.2.11 | displaystring | read-only |
Gets the BUC gateway address (Only for RBUC). **** No respond - message if buc2 not connected. |
buc2IpAddress | 1.3.6.1.4.1.23304.2.2.2.2.12 | displaystring | read-only |
Gets the BUC IP address (Only for RBUC). **** No respond - message if buc2 not connected. |
buc2MACAddress | 1.3.6.1.4.1.23304.2.2.2.2.13 | displaystring | read-only |
Gets the BUC MAC address (Only for RBUC). **** No respond - message if buc2 not connected. |
buc2Netmask | 1.3.6.1.4.1.23304.2.2.2.2.14 | displaystring | read-only |
Gets the BUC netmask (Only for RBUC). **** No respond - message if buc2 not connected. |
buc2RefPower | 1.3.6.1.4.1.23304.2.2.2.2.15 | displaystring | read-only |
Gets the BUC reference power. **** No respond - message if buc2 not connected. |
buc2Config | 1.3.6.1.4.1.23304.2.2.2.2.16 | displaystring | read-only |
Gets the BUC configuration. **** No respond - message if buc2 not connected. |
buc2BuildStandard | 1.3.6.1.4.1.23304.2.2.2.2.17 | displaystring | read-only |
Gets the BUC build standard. **** No respond - message if buc2 not connected. |
buc2Info | 1.3.6.1.4.1.23304.2.2.2.3 | |||
buc2IdInfo | 1.3.6.1.4.1.23304.2.2.2.3.1 | displaystring | read-only |
Gets the module firmware revision, serial number and model. This string will have a zero length if the revision is unknown. **** No respond - message if buc2 not connected. |
buc2Limits | 1.3.6.1.4.1.23304.2.2.2.3.2 | displaystring | read-only |
Gets the limit data for the BUC. Format is: Power meter MIN/MAX , IF,RF and LO frequencies. This string will have a zero length if the revision is unknown. **** No respond - message if buc2 not connected. |
buc2PktProtocolsInfo | 1.3.6.1.4.1.23304.2.2.2.3.3 | displaystring | read-only |
Gets supported packet protocols and the corresponding address ranges. **** No respond - message if buc2 not connected. |
ctrl | 1.3.6.1.4.1.23304.2.2.3 | |||
settings | 1.3.6.1.4.1.23304.2.2.3.1 | |||
operationalMode | 1.3.6.1.4.1.23304.2.2.3.1.1 | integer | read-write |
Sets 7586 operational mode - Auto, Manual Stream1, Stream2. |
onlineStream | 1.3.6.1.4.1.23304.2.2.3.1.2 | integer | read-write |
Sets the online stream. |
waveguideSwitch | 1.3.6.1.4.1.23304.2.2.3.1.3 | integer | read-write |
Sets Waveguide switch Rx+Tx, Rx/Tx and Tx Only. |
startupTime | 1.3.6.1.4.1.23304.2.2.3.1.4 | integer | read-write |
Sets Startup time. |
lnbCurrentLimit | 1.3.6.1.4.1.23304.2.2.3.1.5 | displaystring | read-write |
Sets LNB current limits. |
ledState | 1.3.6.1.4.1.23304.2.2.3.1.6 | integer | read-write |
Sets 7586 LED. |
refSource | 1.3.6.1.4.1.23304.2.2.3.1.7 | integer | read-write |
Sets 7586 reference state. |
refTrim | 1.3.6.1.4.1.23304.2.2.3.1.8 | displaystring | read-write |
Sets 7586 reference trim. |
refThresh | 1.3.6.1.4.1.23304.2.2.3.1.9 | displaystring | read-write |
Sets 7586 reference alarm treshold. |
refPwr | 1.3.6.1.4.1.23304.2.2.3.1.10 | displaystring | read-only |
Gets 7586 reference power. |
ipAddr | 1.3.6.1.4.1.23304.2.2.3.1.11 | displaystring | read-only |
Gets the 7586 IP address. |
macAddress | 1.3.6.1.4.1.23304.2.2.3.1.12 | displaystring | read-only |
Gets the 7586 MAC address. |
netmask | 1.3.6.1.4.1.23304.2.2.3.1.13 | displaystring | read-only |
Gets the 7586 netmask. |
gateway | 1.3.6.1.4.1.23304.2.2.3.1.14 | displaystring | read-only |
Gets the 7586 gateway address. |
status | 1.3.6.1.4.1.23304.2.2.3.2 | |||
lnbCurrent | 1.3.6.1.4.1.23304.2.2.3.2.1 | displaystring | read-only |
Sets 7586 LNB current. |
lnbVoltage | 1.3.6.1.4.1.23304.2.2.3.2.2 | displaystring | read-only |
Sets 7586 LNB voltage. |
faults | 1.3.6.1.4.1.23304.2.2.3.2.3 | integer | read-only |
Gets the current fault status. |
info | 1.3.6.1.4.1.23304.2.2.3.3 | |||
idInfo | 1.3.6.1.4.1.23304.2.2.3.3.1 | displaystring | read-only |
Gets the module firmware revision, serial number and model. This string will have a zero length if the revision is unknown. |