RC-PORT-MIB: View SNMP OID List / Download MIB

VENDOR: RAPID CITY COMMUNICATION


 Home MIB: RC-PORT-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
       rcPortMib 1.3.6.1.4.1.2272.1.4.10.0
Enterprise MIB for the Accelar product family.
       rcPortTable 1.3.6.1.4.1.2272.1.4.10.1 no-access
Port table
           rcPortEntry 1.3.6.1.4.1.2272.1.4.10.1.1 no-access
Entry containing info. for a particular port
               rcPortIndex 1.3.6.1.4.1.2272.1.4.10.1.1.1 interfaceindex read-only
An index value that uniquely identifies a port. This value is similar to ifIndex in MIB2.
               rcPortType 1.3.6.1.4.1.2272.1.4.10.1.1.2 integer read-only
Port type Enumeration: 'rc1000BaseTXPOE': 63, 'rcGbic1300SeFx': 104, 'rc10BaseF': 6, 'rcGbic1570Zx': 80, 'rcOc3cPosSM': 29, 'rcGbic1470Xd': 67, 'rcGbic1570': 38, 'rcGbic1470': 33, 'rcGbic1570APD': 47, 'rc1000XFP': 57, 'rcGbic1610Zx': 82, 'rcGbic1510Xd': 69, 'rcGbic1490Zx': 76, 'rc100BaseF': 3, 'rcGbic1490Bx': 85, 'rcGbicNone': 22, 'rcGbic1510Zx': 77, 'rcGbic1300Lx': 89, 'rcGbic1510APD': 44, 'rcOc3cPosMM': 30, 'rcGbic1530Zx': 78, 'rc10GbicCX': 106, 'rcPosMMF': 7, 'rc100BaseFX': 100, 'rcGbic1530APD': 45, 'rcGbicLx': 10, 'rc10GbLRM': 95, 'rc10GbOther': 62, 'rc1GbFD': 94, 'rcGbic1590': 39, 'rcGbic1610': 40, 'rcOc3cAtmSM': 25, 'rcGbic1470Zx': 75, 'rcGbic1550Xd': 71, 'rcGbic1570Xd': 72, 'rcGbic1510': 35, 'rc100BaseTX': 1, 'rcGbic1610APD': 49, 'rcGbic1590Xd': 73, 'rc10GbDWDMR': 96, 'rcGbicBx': 55, 'rc10GbDWDMW': 97, 'rcGbic1200Lx': 88, 'rcGbic1530Xd': 70, 'rc100BaseT2': 2, 'rcGbic1310Lx': 90, 'rcRmon': 41, 'rcGbicMTRJ': 103, 'rcOc12cSM': 18, 'rc10GbLW': 50, 'rcLogicalServerPort': 52, 'rc1000BaseF': 4, 'rc10GbLR': 51, 'rcOc3cCOPPER': 17, 'rcGbicSx': 11, 'rc1000BaseT': 23, 'rcGbic1590APD': 48, 'rcGbic1470APD': 42, 'rcOc12cAtmMM': 28, 'rcGbic1590Zx': 81, 'rcOc3cMM': 16, 'rcGbic1530': 36, 'rcGbic1550Zx': 79, 'rcGbic1490APD': 43, 'rcGbicZx': 24, 'rcOc12cMM': 19, 'rc1000BaseTX': 53, 'rcGbicEx': 86, 'rc100BaseTXPOE': 54, 'rcGbic1490': 34, 'rc100BaseLX': 99, 'rcGbic850Sx': 87, 'rc10GbER': 60, 'rc10GbEW': 61, 'rcGbic1310Bx': 84, 'rc100BaseSX': 98, 'rcGbic1550APD': 46, 'rc1000BaseDualF': 5, 'rcGbic1550Lx': 92, 'rcOc12cPosSM': 31, 'rcDs3': 20, 'rc10GbSR': 58, 'rc10GbSW': 59, 'rc10GbNone': 56, 'rcGbic1550Ex': 93, 'rc10GbZR': 64, 'rc10GbZW': 65, 'other': 0, 'rcGbic1310Xd': 66, 'rcGbic1550': 37, 'rcGbic1690Zx': 83, 'rcGbicCX': 105, 'rcGbic1610Xd': 74, 'rcOc3cAtmMM': 26, 'rc100BaseBX': 101, 'rcOc12cPosMM': 32, 'rcGbicXd': 12, 'rc100BaseZX': 102, 'rcAtm': 9, 'rcOc3cSM': 15, 'rcGbicOther': 14, 'rcGbicC': 13, 'rcGbic1490Lx': 91, 'rcPosSMF': 8, 'rcE3': 21, 'rcOc12cAtmSM': 27, 'rcGbic1490Xd': 68.
               rcPortConnectorType 1.3.6.1.4.1.2272.1.4.10.1.1.3 integer read-only
Type of connector installed on this port. Enumeration: 'nonRedundant': 1, 'redundant': 2.
               rcPortPerformRouting 1.3.6.1.4.1.2272.1.4.10.1.1.4 truthvalue read-write
Indicate whether this port should perform routing
               rcPortHighPriority 1.3.6.1.4.1.2272.1.4.10.1.1.5 truthvalue read-write
Indicate whether this port should be treated with high priority
               rcPortAction 1.3.6.1.4.1.2272.1.4.10.1.1.6 integer read-write
Port related actions. Enumeration: 'none': 1, 'clearLoopDetectAlarm': 7, 'flushIp': 4, 'flushMacFdb': 2, 'flushArp': 3, 'triggerRipUpdate': 6, 'flushAll': 5.
               rcPortResult 1.3.6.1.4.1.2272.1.4.10.1.1.7 integer read-only
Result from the last Vlan action. Enumeration: 'fail': 4, 'none': 1, 'inProgress': 2, 'success': 3.
               rcPortPrimaryConnector 1.3.6.1.4.1.2272.1.4.10.1.1.8 integer read-write
For ports configured with redundant connectors, this value is used to indicate which connector should be used as the 'active' connector on this port the next time the port is placed into the ifAdminStatus=Up. Enumeration: 'right': 2, 'other': 3, 'left': 1.
               rcPortActiveConnector 1.3.6.1.4.1.2272.1.4.10.1.1.9 integer read-only
For ports configured with redundant connectors, this value is used to indicate which connector is currently the active one. Only one connector can be active an anytime. Enumeration: 'right': 2, 'other': 3, 'left': 1.
               rcPortBackupConnectorStatus 1.3.6.1.4.1.2272.1.4.10.1.1.10 integer read-only
Indicate the status of the link attached to the back-up (non-active) connector. Enumeration: 'down': 2, 'other': 3, 'up': 1.
               rcPortAutoNegotiate 1.3.6.1.4.1.2272.1.4.10.1.1.11 truthvalue read-write
Indicate whether this port enabled for auto negotiations or not.
               rcPortAdminDuplex 1.3.6.1.4.1.2272.1.4.10.1.1.12 integer read-write
Indicates the port duplex type Enumeration: 'full': 2, 'half': 1.
               rcPortOperDuplex 1.3.6.1.4.1.2272.1.4.10.1.1.13 integer read-only
Indicate this port's current duplex value. Enumeration: 'full': 2, 'half': 1.
               rcPortAdminSpeed 1.3.6.1.4.1.2272.1.4.10.1.1.14 integer read-write
Indicate this port's speed. Enumeration: 'mbps1000': 3, 'none': 0, 'mbps100': 2, 'mbps10000': 4, 'mbps10': 1.
               rcPortOperSpeed 1.3.6.1.4.1.2272.1.4.10.1.1.15 integer32 read-only
Indicate this port's current speed value.
               rcPortMltId 1.3.6.1.4.1.2272.1.4.10.1.1.16 integer32 read-only
Indicate which multi-link trunk (MLT) this port is assigned to. If this port is not associated with any MLT, this value will be set to zero(0).
               rcPortLocked 1.3.6.1.4.1.2272.1.4.10.1.1.17 truthvalue read-only
Indicate whether this port is locked.
               rcPortAutoNegotiationSupported 1.3.6.1.4.1.2272.1.4.10.1.1.18 truthvalue read-only
Indicate whether this port can support auto-negotiation.
               rcPortSingleRoutablePort 1.3.6.1.4.1.2272.1.4.10.1.1.19 truthvalue read-only
Indicate whether this port is a single routable port. If this value is true, the port functions like a traditional router port.
               rcPortUnknownMacDiscard 1.3.6.1.4.1.2272.1.4.10.1.1.20 truthvalue read-write
If rcUnknownMacDiscard is set to True, then a packet with an unknown source MAC address is dropped on that port, and other ports then will discard any packets with this MAC address in the destination field. For example, suppose 11:22:33:44:55:66 is an unknown source MAC, packets with source MAC 11:22:33:44:55 coming from this port is discarded, further more, packets with destination MAC 11:22:33:44:55:66 coming from other ports are also discarded, unless this address is later learned on another port or the restriction ages out.
               rcPortNumStateTransition 1.3.6.1.4.1.2272.1.4.10.1.1.21 counter32 read-only
# state transitions.
               rcPortUserPriority 1.3.6.1.4.1.2272.1.4.10.1.1.22 integer read-write
User priority level. Enumeration: 'level0': 0, 'level1': 1, 'level2': 2, 'level3': 3, 'level4': 4, 'level5': 5, 'level6': 6, 'level7': 7.
               rcPortAllowOversizeFrame 1.3.6.1.4.1.2272.1.4.10.1.1.23 truthvalue read-write
Used to specify whether over-size frames should be processed or dropped.
               rcPortQosLevel 1.3.6.1.4.1.2272.1.4.10.1.1.30 integer read-write
Used to specify the Qos level packets, carried on this port, should be processed with. Enumeration: 'level0': 0, 'level1': 1, 'level2': 2, 'level3': 3, 'level4': 4, 'level5': 5, 'level6': 6, 'level7': 7.
               rcPortDiffServEnable 1.3.6.1.4.1.2272.1.4.10.1.1.31 truthvalue read-write
Used to enable/disable the Differentiated Service feature on this port.
               rcPortDiffServType 1.3.6.1.4.1.2272.1.4.10.1.1.32 integer read-write
Used to specify the Differentiated Service type for this port. Enumeration: 'access': 1, 'core': 2, 'none': 0.
               rcPortDiffServIeee8021POverrideEnable 1.3.6.1.4.1.2272.1.4.10.1.1.33 truthvalue read-write
Used to enable/disable the Differentiated Service IEEE 802.1P over-ride feature.
               rcPortVendorDescr 1.3.6.1.4.1.2272.1.4.10.1.1.34 displaystring read-only
Used to show the name of the vendor of this port's connector. Only applicable to ports on a GBIC cards.
               rcPortName 1.3.6.1.4.1.2272.1.4.10.1.1.35 displaystring read-write
This port's name.
               rcPortOctapidId 1.3.6.1.4.1.2272.1.4.10.1.1.36 integer32 read-only
The octapid id of the mirrored port.
               rcPortWan 1.3.6.1.4.1.2272.1.4.10.1.1.37 integer read-write
Indicatie this port's current WAN/LAN mode. Valid for 10 GE only Enumeration: 'wan': 1, 'none': 0, 'lan': 2.
               rcPortTransport 1.3.6.1.4.1.2272.1.4.10.1.1.38 integer read-write
Indicatie this port's current tranport layer. Valid for 10 GE only Enumeration: 'none': 0, 'sdh': 2, 'sonet': 1.
               rcPortMultimediaFilterEnable 1.3.6.1.4.1.2272.1.4.10.1.1.39 truthvalue read-write
Used to enable/disable the Telephony device selected on this port
               rcPortMultimediaDevSelection 1.3.6.1.4.1.2272.1.4.10.1.1.40 displaystring read-write
Used to set/get the selected Multimedia & Telephony Devices on this port. The String is the name of the device in the rcIpFilterMediaDevTable
               rcPortServiceType 1.3.6.1.4.1.2272.1.4.10.1.1.41 integer read-write
Indicates the port functionality. 12uni is used to configure the port to be part of Martini service, tls is used to configure the port to be part of Any2Any VPN service and ip is used to perform the IP routing and mpls if enabled. Enumeration: 'serverl2uni': 4, 'vpls': 2, 'none': 0, 'l2uni': 1, 'ip': 3.
               rcPortMode 1.3.6.1.4.1.2272.1.4.10.1.1.42 integer read-write
The port mode for l2uni service type.If the port is configured for l2uni service type, then the mode can be transparent or switched. Enumeration: 'none': 0, 'transparent': 1, 'switched': 2.
               rcPortAdminRouting 1.3.6.1.4.1.2272.1.4.10.1.1.43 enablevalue read-write
Indicate whether the port is routable.
               rcPortOperRouting 1.3.6.1.4.1.2272.1.4.10.1.1.44 enablevalue read-only
The status of the port whether is routable.
               rcPortPid 1.3.6.1.4.1.2272.1.4.10.1.1.45 integer32 read-only
The pid of the mirrored port.
               rcPortIeee8021POverrideEnable 1.3.6.1.4.1.2272.1.4.10.1.1.46 truthvalue read-write
Used to enable/disable IEEE 802.1P override. If it is enabled, 802.1p vlaue from a tagged frame may not honor.
               rcPortShaperEnable 1.3.6.1.4.1.2272.1.4.10.1.1.47 truthvalue read-write
Used to enable/disable shaper on the port.
               rcPortShaperMaxRate 1.3.6.1.4.1.2272.1.4.10.1.1.48 integer32 read-write
Shaping rate in mega bits per second. Note that actual shaping rate might be different from the configured rate due to the rate granularity of the shaper.
               rcPortShaperBurstSize 1.3.6.1.4.1.2272.1.4.10.1.1.49 integer32 read-write
Burst size in kilo bytes per second. Note that actual burst size might be different from the configured size due to the granularity of the shaper.
               rcPortCpLimitShutDown 1.3.6.1.4.1.2272.1.4.10.1.1.50 truthvalue read-only
A TRUE value indicates if CP Limit shut down the interface.
               rcPortHighSecureEnable 1.3.6.1.4.1.2272.1.4.10.1.1.51 truthvalue read-write
Enable/Disable high secure.
               rcPortTlsPriorityOverride 1.3.6.1.4.1.2272.1.4.10.1.1.52 enablevalue read-write
Enable/Disable tls port priority override feature.
               rcPortVctAbility 1.3.6.1.4.1.2272.1.4.10.1.1.53 integer read-only
If this object is TRUE, then the specified port is hardware-capable of doing the VCT test, if the rcPortAdminStatus is also true. If this object is FALSE, then the hardware cannot do the VCT test regardless of the setting of the rcPortAdminStatus. Enumeration: 'vctCapable': 2, 'vctNotCapable': 1.
               rcPortVctAdminStatus 1.3.6.1.4.1.2272.1.4.10.1.1.54 enablevalue read-write
Admin status for port VCT test. If this object is set to TRUE, then the VCT test can be performed. If it is set to FALSE, then the test cannot be performed, even if the port hardware is capable of doing it. If this variable si read, then the value returned is what was previously written.
               rcPortMrouteStrLimit 1.3.6.1.4.1.2272.1.4.10.1.1.55 integer32 read-write
maximum number of multicast streams that are allowed to ingress to CPU through this port.
               rcPortMrouteStrTimerCheck 1.3.6.1.4.1.2272.1.4.10.1.1.56 integer32 read-write
sampling period to check number of multicast streams that has ingressed CPU through this port.
               rcPortMrouteStrLimitEnable 1.3.6.1.4.1.2272.1.4.10.1.1.57 truthvalue read-write
enable or disable mroute stream limit on port.
               rcPortUpdateDynamicMacQosLevel 1.3.6.1.4.1.2272.1.4.10.1.1.58 enablevalue read-write
It is used to indicate whether to update qos level for dynamic learned mac add resses associated with a port-based vlan when port qos level changes. If it is set to TRUE, qos level for all dynamic learned mac addresses will be changed upon changing port qos level. If it is set to DISABLE, once a mac address is learned, qos level will not updated when port qos level changes.
               rcPortVplsDualHoming 1.3.6.1.4.1.2272.1.4.10.1.1.59 integer read-write
The VPLS dual homing is for VPLS service type only. It can be disable, firstNNI or secondNNI. Enumeration: 'secondNNI': 2, 'firstNNI': 1, 'disable': 0.
               rcPortVplsMgmtVlan 1.3.6.1.4.1.2272.1.4.10.1.1.60 truthvalue read-write
Management Vlan is configured on this port
               rcPortTlsManagedBySp 1.3.6.1.4.1.2272.1.4.10.1.1.61 truthvalue read-write
True/False tls devices on port Managed By Service Provider.
               rcPortAutoNegAd 1.3.6.1.4.1.2272.1.4.10.1.1.62 bits read-write
This object is used to specify the port speed and duplex abilities to be advertised during link negotiation. bit 0 - 10 half duplex advertised bit 1 - 10 full duplex advertised bit 2 - 100 half duplex advertised bit 3 - 100 full duplex advertised bit 4 - 1000 half duplex advertised bit 5 - 1000 full duplex advertised bit 6 - Mac PAUSE frame support advertised bit 7 - Asymmetric PAUSE frame support advertised bit 8 - No advertisements The abilities specified in this object are only used when auto-negotiation is enabled on the port. If all bits in this object are disabled, and auto-negotiation is enabled on the port, then the physical link process on the port will be disabled (if hardware supports this ability). Any change in the value of this bit map will force the PHY to restart the auto-negotiation process. This will have the same effect as physically unplugging and reattaching the cable plant attached to this port. The capabilities being advertised are either all the capabilities supported by the hardware or the user- configured capabilities which is a subset of all the capability supported by hardware. The default value for this object will be all the capabilities supported by the hardware. Note that bit 6 and bit 7 are currently not supported in ERS8600. Bits: 'advertise10Full': 1, 'advertiseMacPause': 6, 'advertise1000Half': 4, 'advertise100Half': 2, 'advertise10Half': 0, 'advertiseAsymPause': 7, 'advertiseNone': 8, 'advertise1000Full': 5, 'advertise100Full': 3.
               rcPortAutoNegAdCapability 1.3.6.1.4.1.2272.1.4.10.1.1.63 bits read-only
This object indicates the port speed and duplex capabilities that hardware can actually support on a port, and which may be advertised by the port using auto-negotiation. Bit 7 tells if a port supports pause frame capabilities (for full-duplex links) as a part of the advertisement. bit 0 - 10 half duplex advertisements bit 1 - 10 full duplex advertisements bit 2 - 100 half duplex advertisements bit 3 - 100 full duplex advertisements bit 4 - 1000 half duplex advertisements bit 5 - 1000 full duplex advertisements bit 6 - Mac PAUSE frame support advertisements bit 7 - Asymmetric PAUSE frame support advertisements If auto negotiation is not supported by the port hardware, then all bits will reflect a value of zero. Bits: 'advertise10Full': 1, 'advertiseMacPause': 6, 'advertise1000Half': 4, 'advertise100Half': 2, 'advertise10Half': 0, 'advertiseAsymPause': 7, 'advertise1000Full': 5, 'advertise100Full': 3.
               rcPortAutoRecoverPort 1.3.6.1.4.1.2272.1.4.10.1.1.64 truthvalue read-write
enable or disable auto recovery of port from action taken by cp-limit, link flap or loop detect features
               rcPortExtCplimitConf 1.3.6.1.4.1.2272.1.4.10.1.1.65 integer read-write
Indicates the port configuration for extended CP-LIMIT Enumeration: 'none': 1, 'softDown': 2, 'hardDown': 3.
               rcPortExtCplimitUtilRate 1.3.6.1.4.1.2272.1.4.10.1.1.66 integer32 read-write
Threshold for Ingress traffic utilization rate of the port for extended CP-LIMIT
               rcPortEgressRateLimit 1.3.6.1.4.1.2272.1.4.10.1.1.67 integer32 read-write
Egress Rate Limit.
               rcPortEgressRateLimitState 1.3.6.1.4.1.2272.1.4.10.1.1.68 enablevalue read-write
Used to enable/disable shape/egress-rate-limit functionality.
               rcPortBpduFilteringTimerCount 1.3.6.1.4.1.2272.1.4.10.1.1.69 timeinterval read-only
The remaining time the port will be disabled due to a BPDU received when BPDU filtering is enabled.
               rcPortBpduFilteringTimeout 1.3.6.1.4.1.2272.1.4.10.1.1.70 timeinterval read-write
The time the port will be disabled when a BPDU is received when BPDU filtering is enabled.
               rcPortBpduFilteringAdminEnabled 1.3.6.1.4.1.2272.1.4.10.1.1.71 truthvalue read-write
Used to enable/disable BPDU filtering.
               rcPortBpduFilteringOperEnabled 1.3.6.1.4.1.2272.1.4.10.1.1.72 truthvalue read-only
Indicates whether BPDU filtering is actually enabled or disabled.
               rcPortQinqEtherType 1.3.6.1.4.1.2272.1.4.10.1.1.73 integer32 read-write
The qinq ether type value. It is hex value. It should be displayed and input as Hex value. It is only be used when port is associated with QnQ service UNI. Otherwise, it would be ignored
               rcPortTrustDscp 1.3.6.1.4.1.2272.1.4.10.1.1.74 truthvalue read-write
Used to enable/disable the trusted DSCP feature. If enabled, the internal qos-level and 802.1p value are derived from the received packet's DSCP value. This MIB object is applicable to ports in 8348GTX so that higher priority IP traffic can bypass the oversubscribed cascading link.
               rcPortCpLimitEnable 1.3.6.1.4.1.2272.1.4.10.1.1.75 enablevalue read-write
Used to enable/disable the control packet rate limit. Specifies whether or not rate limiting is currently in operation for multicast and broadcast packets for the specified port.
               rcPortCpMulticastLimit 1.3.6.1.4.1.2272.1.4.10.1.1.76 integer32 read-write
Used to limit Multicast traffic on the specified port. Sets the limit in packets per second.
               rcPortCpBroadcastLimit 1.3.6.1.4.1.2272.1.4.10.1.1.77 integer32 read-write
Used to limit Broadcast traffic on the specified port. Sets the limit in packets per second.
               rcPortSmartAutoNegotiate 1.3.6.1.4.1.2272.1.4.10.1.1.78 truthvalue read-write
This object indicates whether 'smart' autonegotiation is enabled on a port (smart autonegotiation indicates that the port can sense whether its partner has autonegotiation enabled). This object, when supported, works in conjunction with rcPortAutoNegotiate. It is an inconsistentValue error to set rcPortAutoNegotiate to false(2) and this object to true(1) in the same Set request. Setting the object to true(1) will automatically change rcPortAutoNegotiate to true(1). Similarly, setting rcPortAutoNegotiate to false(2) will automatically change this object to false(2).
               rcPortMepList 1.3.6.1.4.1.2272.1.4.10.1.1.79 octet string read-write
List of Meps assigned to this entry. A mep is consist of ... Domain Name, Association and Mep Id is separated by '.' A list of mep is consist of ..,..,... Each mep is separated by ','. Maximum up 8 meps
               rcPortNumOfMep 1.3.6.1.4.1.2272.1.4.10.1.1.80 integer32 read-only
Used to indicate the number of Meps is assigned to this entry
               rcPortAdacStatus 1.3.6.1.4.1.2272.1.4.10.1.1.81 truthvalue read-write
If enabled, the Nortel IP phones connected to the port will be configured in the voice VLAN.
               rcPortPvid 1.3.6.1.4.1.2272.1.4.10.1.1.82 integer32 read-write
A port Vlan Id associates with ESM and RModule port for OEL2/MIM traffic
               rcPortTdp 1.3.6.1.4.1.2272.1.4.10.1.1.83 enablevalue read-write
This attribute allows to Enable/Disable Transparent Domain Protocol at the port level on the ESM and Power Ranger Card. For the TDP packet to go out on the port, topology should be enabled both at the port and box level also.
               rcPortClockSource 1.3.6.1.4.1.2272.1.4.10.1.1.84 integer read-write
Indicates this port's current WAN clock source. Valid for 10 GE WAN only Enumeration: 'none': 0, 'internal': 2, 'line': 1.
               rcPortIngressRateLimit 1.3.6.1.4.1.2272.1.4.10.1.1.85 integer32 read-write
Limits the amount of traffic from this Ingress port.
               rcPortIngressRateLimitState 1.3.6.1.4.1.2272.1.4.10.1.1.86 enablevalue read-write
Used to enable/disable police/ingress-rate-limit functionality.
               rcPortVrfIdList 1.3.6.1.4.1.2272.1.4.10.1.1.87 idlist read-only
The set of VRF ids to which this port belongs.
               rcPortCfmVid 1.3.6.1.4.1.2272.1.4.10.1.1.88 integer32 read-write
CFM default port vid
               rcPortUserLabel1 1.3.6.1.4.1.2272.1.4.10.1.1.89 displaystring read-write
User provided field. Used to give extra management information/data
               rcPortUserLabel2 1.3.6.1.4.1.2272.1.4.10.1.1.90 displaystring read-write
User provided additional field. Used to give extra management information/data
               rcPortClearCfmStats 1.3.6.1.4.1.2272.1.4.10.1.1.91 truthvalue read-write
To clear the port counter
               rcPortInterfaceType 1.3.6.1.4.1.2272.1.4.10.1.1.92 integer read-write
This value indicates whether a port is of type . A port can be included in any EVPN service only if this attribute is set to uni. If the port is not part of any VLAN the interface-type is set to silent. Before adding a port to a VLAN the interface type should be changed to normal. Enumeration: 'uni': 3, 'silent': 2, 'normal': 1.
               rcPortCfmControlMep 1.3.6.1.4.1.2272.1.4.10.1.1.93 displaystring read-write
MEP assigned for CFM Control. A mep consists of ... Domain Name, Association and Mep Id is separated by '.'
               rcPortMtu 1.3.6.1.4.1.2272.1.4.10.1.1.94 integer32 read-write
Port Mtu
               rcPortMtuState 1.3.6.1.4.1.2272.1.4.10.1.1.95 enablevalue read-write
Used to enable/disable Port Mtu functionality.
               rcPortVrfNameList 1.3.6.1.4.1.2272.1.4.10.1.1.96 octet string read-only
The set of VRF names to which this port belongs.
               rcPortBrouterVrfId 1.3.6.1.4.1.2272.1.4.10.1.1.97 vrfidentifier read-write
Gives the VRF Id for this Brouter port.
               rcPortBrouterVrfName 1.3.6.1.4.1.2272.1.4.10.1.1.98 displaystring read-only
Gives the VRF Name for this Brouter port.
               rcPortVrfCount 1.3.6.1.4.1.2272.1.4.10.1.1.99 counter32 read-only
The total number of VRFs this port is associated to.
               rcPortCtrlPktDropLimitEnable 1.3.6.1.4.1.2272.1.4.10.1.1.100 enablevalue read-write
Used to enable/disable Control Packets Drop Rate Limiter functionality.
               rcPortCtrlPktDropLimit 1.3.6.1.4.1.2272.1.4.10.1.1.101 integer32 read-write
Indicates the Control Packet drop rate limit value
               rcPortCtrlPktShutdownLimitEnable 1.3.6.1.4.1.2272.1.4.10.1.1.102 enablevalue read-write
Used to enable/disable Control Packets Shutdown Rate Limiter functionality.
               rcPortCtrlPktShutdownLimit 1.3.6.1.4.1.2272.1.4.10.1.1.103 integer32 read-write
Indicates the Control Packet shutdown rate Limit value
               rcPortCtrlPktShutdownRtExceeded 1.3.6.1.4.1.2272.1.4.10.1.1.104 truthvalue read-write
Indicates if the Shutdown rate has been exceeded on the port
               rcPortCtrlPktDropRtExceeded 1.3.6.1.4.1.2272.1.4.10.1.1.105 truthvalue read-write
Indicates if the Drop rate has been exceeded on the port
               rcPortDhcpOption82SubscriberId 1.3.6.1.4.1.2272.1.4.10.1.1.106 displaystring read-write
This object contains the DHCP option 82 subscriber ID string to be used in sub-option 6. If the value is an empty string, then sub-option 6 is not included in option 82
       rcPortPcapTable 1.3.6.1.4.1.2272.1.4.10.2 no-access
Port pcap Table
           rcPortPcapEntry 1.3.6.1.4.1.2272.1.4.10.2.1 no-access
Entry containing pcap info. for a particular port
               rcPortPcapIndex 1.3.6.1.4.1.2272.1.4.10.2.1.1 interfaceindex read-only
An index value that uniquely identifies a port. This value is similar to ifIndex in MIB2.
               rcPortPcapEnable 1.3.6.1.4.1.2272.1.4.10.2.1.2 truthvalue read-write
To enable pcap for the port
               rcPortPcapMode 1.3.6.1.4.1.2272.1.4.10.2.1.3 integer read-write
Mode in which pcap is enabled Enumeration: 'both': 3, 'txFilter': 5, 'tx': 1, 'rx': 2, 'rxFilter': 4, 'bothFilter': 6.
               rcPortPcapFilterListSize 1.3.6.1.4.1.2272.1.4.10.2.1.4 integer32 read-only
Used to indicate the number of filter list(s) that are assigned to this port.
               rcPortPcapFilterList 1.3.6.1.4.1.2272.1.4.10.2.1.5 octet string read-write
Used to indicate zero or more filter lists that are associated with this port for pcap. Each filter list identifier is stored as two bytes in this array starting from offset zero. Any unused bytes should be set to zero.
               rcPortPcapAclFilterListSize 1.3.6.1.4.1.2272.1.4.10.2.1.6 integer32 read-only
Used to indicate the number of ACL filter(s) that are assigned to this port which has mirror set as global-action.
               rcPortPcapAclFilterList 1.3.6.1.4.1.2272.1.4.10.2.1.7 octet string read-write
Used to indicate zero or more ACL filter lists that are associated with this port for pcap (has mirror set as global-action). Each ACL filter list identifier is stored as two bytes in this array starting from offset zero. Any unused bytes should be set to zero.
       rcPortPoe 1.3.6.1.4.1.2272.1.4.10.3
           rcPortPoePseIndexTable 1.3.6.1.4.1.2272.1.4.10.3.1 no-access
Port table
               rcPortPoePseIndexEntry 1.3.6.1.4.1.2272.1.4.10.3.1.1 no-access
Entry containing info. for a particular port
                   rcPortPoePseIndexIfIndex 1.3.6.1.4.1.2272.1.4.10.3.1.1.1 interfaceindex read-only
An index value that uniquely identifies an interface to a PSE port device. The interface identified by a particular value of this index is the same interface as identified by the same value of ifIndex.
                   rcPortPoePseIndexGroupIndex 1.3.6.1.4.1.2272.1.4.10.3.1.1.2 integer32 read-only
An index value that uniquely identifies the group containing the port to which a power Etherenet PSE is connected. Group means box in the stack, module in a rack and the value 1 MUST be used for non-modular devices.
                   rcPortPoePseIndexPortIndex 1.3.6.1.4.1.2272.1.4.10.3.1.1.3 integer32 read-only
This variable uniquely identifies the power Ethernet PSE port within group rcPoePseGroupIndex to which the power Ethernet PSE entry is connected.
           rcPortPoeMainPseExtnTable 1.3.6.1.4.1.2272.1.4.10.3.2 no-access
Port table
               rcPortPoeMainPseExtnEntry 1.3.6.1.4.1.2272.1.4.10.3.2.1 no-access
Entry containing info. for a particular port
                   rcPortPoeMainPseExtnGroupIndex 1.3.6.1.4.1.2272.1.4.10.3.2.1.1 integer32 read-only
An index value that uniquely identifies an interface to a PSE port device. The interface identified by a particular value of this index is the same interface as identified by the same value of ifIndex.
                   rcPortPoeMainPseExtnPwrAdmin 1.3.6.1.4.1.2272.1.4.10.3.2.1.2 enablevalue read-write
An index value that uniquely identifies the group containing the port to which a power Etherenet PSE is connected. Group means box in the stack, module in a rack and the value 1 MUST be used for as identified by the same value of ifIndex.
                   rcPortPoeMainPseExtnPwrPriority 1.3.6.1.4.1.2272.1.4.10.3.2.1.3 integer read-write
An index value that uniquely identifies the group containing the port to which a power Etherenet PSE is connected. Group means box in the stack, module in a rack and the value 1 MUST be used for as identified by the same value of ifIndex. Enumeration: 'high': 2, 'critical': 1, 'low': 3.
                   rcPortPoeMainPseExtnDeviceDetectType 1.3.6.1.4.1.2272.1.4.10.3.2.1.4 integer read-write
An index value that uniquely identifies the group containing the port to which a power Etherenet PSE is connected. Group means box in the stack, module in a rack and the value 1 MUST be used for as identified by the same value of ifIndex. Enumeration: 'p802dot3afAndLegacy': 2, 'p802dot3af': 1.
                   rcPortPoeMainPseExtnPwrLimit 1.3.6.1.4.1.2272.1.4.10.3.2.1.5 integer32 read-write
The maximum available PoE power of the main PSE expressed in Watts.
           rcPortPoePsePortExtnTable 1.3.6.1.4.1.2272.1.4.10.3.3 no-access
Port table
               rcPortPoePsePortExtnEntry 1.3.6.1.4.1.2272.1.4.10.3.3.1 no-access
Entry containing info. for a particular port
                   rcPortPoePsePortExtnGroupIndex 1.3.6.1.4.1.2272.1.4.10.3.3.1.1 integer32 read-only
An index value that uniquely identifies an interface to a PSE port device. The interface identified by a particular value of this index is the same interface as identified by the same value of ifIndex.
                   rcPortPoePsePortExtnPortIndex 1.3.6.1.4.1.2272.1.4.10.3.3.1.2 integer32 read-only
An index value that uniquely identifies an interface to a PSE port device. The interface identified by a particular value of this index is the same interface as identified by the same value of ifIndex.
                   rcPortPoePsePortExtnPwrLimit 1.3.6.1.4.1.2272.1.4.10.3.3.1.3 integer32 read-write
An index value that uniquely identifies the group containing the port to which a power Etherenet PSE is connected. Group means box in the stack, module in a rack and the value 1 MUST be used for as identified by the same value of ifIndex.
                   rcPortPoePsePortExtnMeasuredVolt 1.3.6.1.4.1.2272.1.4.10.3.3.1.4 integer32 read-only
An index value that uniquely identifies the group containing the port to which a power Etherenet PSE is connected. Group means box in the stack, module in a rack and the value 1 MUST be used for as identified by the same value of ifIndex.
                   rcPortPoePsePortExtnMeasuredCurrent 1.3.6.1.4.1.2272.1.4.10.3.3.1.5 integer32 read-only
An index value that uniquely identifies the group containing the port to which a power Etherenet PSE is connected. Group means box in the stack, module in a rack and the value 1 MUST be used for as identified by the same value of ifIndex.
                   rcPortPoePsePortExtnPwrConsumpt 1.3.6.1.4.1.2272.1.4.10.3.3.1.6 integer32 read-only
An index value that uniquely identifies the group containing the port to which a power Etherenet PSE is connected. Group means box in the stack, module in a rack and the value 1 MUST be used for as identified by the same value of ifIndex.
       rcPortLacpTable 1.3.6.1.4.1.2272.1.4.10.4 no-access
Port LACP table
           rcPortLacpEntry 1.3.6.1.4.1.2272.1.4.10.4.1 no-access
Entry containing info. for a particular port
               rcPortLacpAdminEnable 1.3.6.1.4.1.2272.1.4.10.4.1.1 truthvalue read-write
Administratively enable/disable LACP on a port
               rcPortLacpOperEnable 1.3.6.1.4.1.2272.1.4.10.4.1.2 truthvalue read-only
Indicates if LACP is operationally enabled or disabled on a port
               rcPortLacpFastPeriodicTime 1.3.6.1.4.1.2272.1.4.10.4.1.3 integer32 read-write
The number of miliseconds between periodic transmissions using Short Timeouts.
               rcPortLacpSlowPeriodicTime 1.3.6.1.4.1.2272.1.4.10.4.1.4 integer32 read-write
The number of miliseconds between periodic transmissions using LONG Timeouts.
               rcPortLacpTimeoutScale 1.3.6.1.4.1.2272.1.4.10.4.1.5 integer32 read-write
Scalar value used to calculate timeout time from periodic time. Timeout = PeriodicTime * TimeoutScale
               rcPortLacpAggrWaitTime 1.3.6.1.4.1.2272.1.4.10.4.1.6 integer32 read-write
The number of mili seconds to delay aggregation to allow multiple links to aggregate simultaneously.
               rcPortLacpFastPeriodicTimeOper 1.3.6.1.4.1.2272.1.4.10.4.1.7 integer32 read-only
The operating value of fast periodic timer on the port.
               rcPortLacpSlowPeriodicTimeOper 1.3.6.1.4.1.2272.1.4.10.4.1.8 integer32 read-only
The operating value of slow periodic timer on the port.
               rcPortLacpTimeoutScaleOper 1.3.6.1.4.1.2272.1.4.10.4.1.9 integer32 read-only
The operating value of timeout scale on the port.
               rcPortLacpAggrWaitTimeOper 1.3.6.1.4.1.2272.1.4.10.4.1.10 integer32 read-only
The operating value of aggreagate wait time on port.
       rcPortVLacpTable 1.3.6.1.4.1.2272.1.4.10.5 no-access
Port Virtual LACP table
           rcPortVLacpEntry 1.3.6.1.4.1.2272.1.4.10.5.1 no-access
Entry containing info. for a particular port
               rcPortVLacpAdminEnable 1.3.6.1.4.1.2272.1.4.10.5.1.1 truthvalue read-write
Administratively enable/disable Virtual LACP on a port
               rcPortVLacpOperEnable 1.3.6.1.4.1.2272.1.4.10.5.1.2 truthvalue read-only
Indicates if Virtual LACP is operationally enabled or disabled on a port
               rcPortVLacpFastPeriodicTimer 1.3.6.1.4.1.2272.1.4.10.5.1.3 integer32 read-write
The number of miliseconds between periodic transmissions using Short Timeouts
               rcPortVLacpSlowPeriodicTimer 1.3.6.1.4.1.2272.1.4.10.5.1.4 integer32 read-write
The number of miliseconds between periodic transmissions using LONG Timeouts.
               rcPortVLacpTimeout 1.3.6.1.4.1.2272.1.4.10.5.1.5 integer read-write
Timeout control value. Long or Short Timeout Enumeration: 'short': 1, 'long': 2.
               rcPortVLacpTimeoutScale 1.3.6.1.4.1.2272.1.4.10.5.1.6 integer32 read-write
Scalar value used to calculate timeout time from periodic time. Timeout = PeriodicTime * TimeoutScale
               rcPortVLacpEtherType 1.3.6.1.4.1.2272.1.4.10.5.1.7 integer32 read-write
VLACP Protocol Identification. The id value is in Hex
               rcPortVLacpEtherMacAddress 1.3.6.1.4.1.2272.1.4.10.5.1.8 macaddress read-write
Multicast Mac Address exclusively used for VLACPDU's
               rcPortVLacpPortState 1.3.6.1.4.1.2272.1.4.10.5.1.9 integer read-only
Display the Vlacp Port State. Enumeration: 'down': 2, 'up': 1.
               rcPortVLacpDualHomingEnable 1.3.6.1.4.1.2272.1.4.10.5.1.10 truthvalue read-write
Enable/Disable Dual homing on Virtual LACP on a port
       rcPortRemoteMirroringTable 1.3.6.1.4.1.2272.1.4.10.6 no-access
Port Remote Mirroring Table
           rcPortRemoteMirroringEntry 1.3.6.1.4.1.2272.1.4.10.6.1 no-access
Entry containing remote mirroring info. for a particular port
               rcPortRemoteMirroringIndex 1.3.6.1.4.1.2272.1.4.10.6.1.1 interfaceindex read-only
An index value that uniquely identifies a port. This value is similar to ifIndex in MIB2.
               rcPortRemoteMirroringEnable 1.3.6.1.4.1.2272.1.4.10.6.1.2 truthvalue read-only
To enable remote Mirroring for the port
               rcPortRemoteMirroringMode 1.3.6.1.4.1.2272.1.4.10.6.1.3 integer read-only
Mode in which remote mirroring is enabled Enumeration: 'source': 1, 'termination': 2.
               rcPortRemoteMirroringSrcMac 1.3.6.1.4.1.2272.1.4.10.6.1.4 macaddress read-only
Source Mac of the remote mirrored packet. Remote mirroring packet will be send with this source mac address
               rcPortRemoteMirroringDstMac 1.3.6.1.4.1.2272.1.4.10.6.1.5 macaddress read-only
Destination Mac of the remote mirrored packet. Packets will be bridged to this mac address. Remote mirroring packet will be send to this mac address
               rcPortRemoteMirroringEtherType 1.3.6.1.4.1.2272.1.4.10.6.1.6 integer32 read-only
Ethertype of the remote mirrored packet. Packets will be send with this ethertype
               rcPortRemoteMirroringVlanIdListSize 1.3.6.1.4.1.2272.1.4.10.6.1.7 integer32 read-only
Used to indicate the number of VLAN IDs that are assigned to this port.
               rcPortRemoteMirroringVlanIdList 1.3.6.1.4.1.2272.1.4.10.6.1.8 octet string read-only
This field is used only if the port is assigned as remote mirroring termination port. Represents zero or more filter lists vlan in which the Destination Mac address resides. Each VLAN ID is stored as two bytes in this array starting from offset zero. Any unused bytes should be set to zero.
               rcPortRemoteMirroringRowStatus 1.3.6.1.4.1.2272.1.4.10.6.1.9 rowstatus read-only
RowStatus
       rcPortVlacpSessionTable 1.3.6.1.4.1.2272.1.4.10.7 no-access
A table used to maintain Vlacp session values.
           rcPortVlacpSessionEntry 1.3.6.1.4.1.2272.1.4.10.7.1 no-access
Entry containing Vlacp Session information regarding a particular port or mlt.
               rcPortVlacpSessionIfIndex 1.3.6.1.4.1.2272.1.4.10.7.1.1 integer32 no-access
IfIndex of the port or Mlt
               rcPortVlacpSessionSesNumber 1.3.6.1.4.1.2272.1.4.10.7.1.2 integer32 no-access
Session number of an IfIndex
               rcPortVlacpSessionSrcMacAddress 1.3.6.1.4.1.2272.1.4.10.7.1.3 macaddress read-only
Mac Address for the session
               rcPortVlacpSessionRxTimer 1.3.6.1.4.1.2272.1.4.10.7.1.4 integer32 read-only
The Rx timer for the session
               rcPortVlacpSessionValidbit 1.3.6.1.4.1.2272.1.4.10.7.1.5 integer read-only
The valid bit for the session Enumeration: 'inValidSession': 0, 'validSession': 1.
               rcPortVlacpSessionInPktCount 1.3.6.1.4.1.2272.1.4.10.7.1.6 integer32 read-only
The In packet count for the session
       rcPortMgmtLinkTable 1.3.6.1.4.1.2272.1.4.10.8 no-access
Port card mgmt port link table
           rcPortMgmtLinkEntry 1.3.6.1.4.1.2272.1.4.10.8.1 no-access
Entry containing info. for a particular mgmt port in I/O card
               rcPortMgmtLinkIndex 1.3.6.1.4.1.2272.1.4.10.8.1.1 interfaceindex read-only
IfIndex of the port.
               rcPortMgmtLinkDescr 1.3.6.1.4.1.2272.1.4.10.8.1.2 displaystring read-only
Port description
               rcPortMgmtLinkOperStatus 1.3.6.1.4.1.2272.1.4.10.8.1.3 integer read-only
admin status of the mgmt port Enumeration: 'down': 2, 'unknown': 3, 'up': 1.
               rcPortMgmtLinkAutoNegotiate 1.3.6.1.4.1.2272.1.4.10.8.1.4 truthvalue read-only
Auto-negotiation status of the port
               rcPortMgmtLinkDuplex 1.3.6.1.4.1.2272.1.4.10.8.1.5 integer read-only
duplex setting for the port Enumeration: 'full': 2, 'half': 1.
               rcPortMgmtLinkSpeed 1.3.6.1.4.1.2272.1.4.10.8.1.6 integer read-only
speed setting for this port. Enumeration: 'mbps1000': 3, 'none': 0, 'mbps100': 2, 'mbps10': 1.
       rcPortFlushFdbTable 1.3.6.1.4.1.2272.1.4.10.9 no-access
Port Flush Fdbtable
           rcPortFlushFdbEntry 1.3.6.1.4.1.2272.1.4.10.9.1 no-access
port based deletion of mac addresses learned or discarded on that port
               rcPortFlushFdbAddress 1.3.6.1.4.1.2272.1.4.10.9.1.1 displaystring read-write
Mac Address to be deleted.
               rcPortFlushFdbVlanId 1.3.6.1.4.1.2272.1.4.10.9.1.2 integer32 read-write
vlan Id associated with the Mac Address
       rcPortRemotePortShutdownTable 1.3.6.1.4.1.2272.1.4.10.10 no-access
A list of RemotePortShutdown port info.
             rcPortRemotePortShutdownEntry 1.3.6.1.4.1.2272.1.4.10.10.1 no-access
A RemotePortShutdown table entry.
                 rcPortRemotePortShutdownIfIndex 1.3.6.1.4.1.2272.1.4.10.10.1.1 interfaceindex no-access
The ifIndex value for a port.
                 rcPortRemotePortShutdownEnabled 1.3.6.1.4.1.2272.1.4.10.10.1.2 truthvalue read-write
This object controls whether the Remote-Port-Shutdown feature is enabled or disabled on a port.
                 rcPortRemotePortShutdownHoldTimer 1.3.6.1.4.1.2272.1.4.10.10.1.3 integer32 read-write
Indicates the time period after a port has been shutdown during which it will remain down, regardless of any CCMs received during that time period.
                 rcPortRemotePortShutdownStatus 1.3.6.1.4.1.2272.1.4.10.10.1.4 integer read-only
This object indicates whether a port is shutdown by the remote port shutdown feature. Enumeration: 'down': 2, 'up': 1.
                 rcPortRemotePortShutdownLocalMacAddress 1.3.6.1.4.1.2272.1.4.10.10.1.5 macaddress read-only
Local MAC address.
                 rcPortRemotePortShutdownRemoteMacAddress 1.3.6.1.4.1.2272.1.4.10.10.1.6 macaddress read-only
Remote MAC address.
 rcPortLock 1.3.6.1.4.1.2272.1.4.11
       rcPortLockEnable 1.3.6.1.4.1.2272.1.4.11.1 truthvalue read-write
Indicate whether the port lock feature is enabled.
       rcPortLockLockedPorts 1.3.6.1.4.1.2272.1.4.11.2 portset read-write
The set of ports that are administratively locked. Locked ports cannot be modified in anyway until the port is unlocked first.
   rcTestExtTable 1.3.6.1.4.1.2272.1.11.1 no-access
Test extension table. This table augments the standard ifTestTable table in RFC1573.
       rcTestEntry 1.3.6.1.4.1.2272.1.11.1.1 no-access
Proprietary test variables.
           rcTestExtIfIndex 1.3.6.1.4.1.2272.1.11.1.1.1 interfaceindex read-only
The index value which uniquely identifies the interface to which this entry is applicable. The interface identified by a particular value of this index is the same interface as identified by the same value of ifIndex.
           rcTestExtPassCount 1.3.6.1.4.1.2272.1.11.1.1.2 integer32 read-only
The number of iterations of the test case that completed successfully.
           rcTestExtFailCount 1.3.6.1.4.1.2272.1.11.1.1.3 integer32 read-only
The number of iterations of the test case that failed.
   rcTestTypes 1.3.6.1.4.1.2272.1.11.2
       rcTestTypesFabric 1.3.6.1.4.1.2272.1.11.2.1
       rcTestTypesArTable 1.3.6.1.4.1.2272.1.11.2.2
       rcTestTypesExtLoopBack 1.3.6.1.4.1.2272.1.11.2.3
   rcTestCodes 1.3.6.1.4.1.2272.1.11.3
       rcTestCodesNoReceive 1.3.6.1.4.1.2272.1.11.3.1
       rcTestCodesBadSeq 1.3.6.1.4.1.2272.1.11.3.2
       rcTestCodesBadLen 1.3.6.1.4.1.2272.1.11.3.3
       rcTestCodesBadData 1.3.6.1.4.1.2272.1.11.3.4
   rcStatTable 1.3.6.1.4.1.2272.1.12.1 no-access
A table used to store port statistics.
       rcStatEntry 1.3.6.1.4.1.2272.1.12.1.1 no-access
interface counters
           rcStatPortIndex 1.3.6.1.4.1.2272.1.12.1.1.1 interfaceindex read-only
An index value that uniquely identifies a port. This value is similar to ifIndex in MIB2.
           rcStatFrameTooShorts 1.3.6.1.4.1.2272.1.12.1.1.2 counter32 read-only
The total number of frames that are too short that were encountered on this interface.
           rcStatBridgeInUnicastFrames 1.3.6.1.4.1.2272.1.12.1.1.3 counter32 read-only
The total number of incoming unicast frames that were bridged.
           rcStatBridgeInMulticastFrames 1.3.6.1.4.1.2272.1.12.1.1.4 counter32 read-only
The total number of incoming multicast frames that were bridged.
           rcStatBridgeInBroadcastFrames 1.3.6.1.4.1.2272.1.12.1.1.5 counter32 read-only
The total number of incoming broadcast frames that were bridged.
           rcStatBridgeInDiscards 1.3.6.1.4.1.2272.1.12.1.1.6 counter32 read-only
The total number of frames that were discarded by the bridging entity.
           rcStatBridgeOutUnicastFrames 1.3.6.1.4.1.2272.1.12.1.1.7 counter32 read-only
The total number of outgoing unicast frames that were bridged.
           rcStatBridgeOutMulticastFrames 1.3.6.1.4.1.2272.1.12.1.1.8 counter32 read-only
The total number of outgoing multicast frames that were bridged.
           rcStatBridgeOutBroadcastFrames 1.3.6.1.4.1.2272.1.12.1.1.9 counter32 read-only
The total number of outgoing broadcast frames that were bridged.
           rcStatRouteInUnicastFrames 1.3.6.1.4.1.2272.1.12.1.1.10 counter32 read-only
The total number of incoming unicast frames that were routed.
           rcStatRouteInMulticastFrames 1.3.6.1.4.1.2272.1.12.1.1.11 counter32 read-only
The total number of incoming multicast frames that were routed.
           rcStatRouteInDiscards 1.3.6.1.4.1.2272.1.12.1.1.12 counter32 read-only
The total number of frames that were discarded by the routing entity.
           rcStatRouteOutUnicastFrames 1.3.6.1.4.1.2272.1.12.1.1.13 counter32 read-only
The total number of outgoing unicast frames that were routed.
           rcStatRouteOutMulticastFrames 1.3.6.1.4.1.2272.1.12.1.1.14 counter32 read-only
The total number of outgoing multicast frames that were routed.
           rcStatStgForwardTransitions 1.3.6.1.4.1.2272.1.12.1.1.15 counter32 read-only
The number of times this port has transitioned from the Learning state to the Forwarding state.
           rcStatStgInConfigBpdus 1.3.6.1.4.1.2272.1.12.1.1.16 counter32 read-only
Received Config BPDUs
           rcStatStgInTcnBpdus 1.3.6.1.4.1.2272.1.12.1.1.17 counter32 read-only
Received TCN BPDUs
           rcStatStgInBadBpdus 1.3.6.1.4.1.2272.1.12.1.1.18 counter32 read-only
Received bad BPDUs
           rcStatStgOutConfigBpdus 1.3.6.1.4.1.2272.1.12.1.1.19 counter32 read-only
Transmitted config BPDUs
           rcStatStgOutTcnBpdus 1.3.6.1.4.1.2272.1.12.1.1.20 counter32 read-only
Transmitted TCN BPDUs
           rcStatBridgeOutFrames 1.3.6.1.4.1.2272.1.12.1.1.21 counter32 read-only
Used by the Accelar 8000 product family to account for all transmitted bridge unicast, broadcast, and multicast packets. The individual counters are not supported.
           rcStatPbtUnknownDropCount 1.3.6.1.4.1.2272.1.12.1.1.22 counter64 read-only
Count of PBT packets dropped due to unknown destination MAC
           rcStatCtrlPktRtLimitTotalCnt 1.3.6.1.4.1.2272.1.12.1.1.23 counter64 read-only
Total count of control packets that is passed for rate limiting
           rcStatCtrlPktRtLimitDropCnt 1.3.6.1.4.1.2272.1.12.1.1.24 counter64 read-only
Count of control packets dropped after rate limiting