RBUC-MIB: View SNMP OID List / Download MIB
VENDOR: CODAN LIMITED
Home | MIB: RBUC-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
rbucMIB | 1.3.6.1.4.1.23304.2.1 |
The Structure of Management Information for the Codan enterprise. Copyright(c) 2009 All rights reserved |
||
configuration | 1.3.6.1.4.1.23304.2.1.1 | |||
txSettings | 1.3.6.1.4.1.23304.2.1.1.1 | |||
txOn | 1.3.6.1.4.1.23304.2.1.1.1.1 | integer | read-write |
Sets Tx on/off. |
txDefault | 1.3.6.1.4.1.23304.2.1.1.1.2 | truthvalue | read-write |
Sets Tx default 1-last 0-off. |
txAttenuator | 1.3.6.1.4.1.23304.2.1.1.1.3 | integer | read-write |
Sets/Gets Tx attenuation value in 1dBm steps. |
pktProtocol | 1.3.6.1.4.1.23304.2.1.1.2 | |||
protocol | 1.3.6.1.4.1.23304.2.1.1.2.1 | integer | read-write |
Sets/Gets packet protocol 0 - ASCII, 1 - CODAN, 2 - . |
address | 1.3.6.1.4.1.23304.2.1.1.2.2 | integer | read-write |
Sets/Gets packet address: 0-31 NDSatcom ... |
rcSetting | 1.3.6.1.4.1.23304.2.1.1.3 | |||
mode | 1.3.6.1.4.1.23304.2.1.1.3.1 | integer | read-write |
Sets/Gets redundancy mode 0-none, 1-warm, 2-hot. |
onLine | 1.3.6.1.4.1.23304.2.1.1.3.2 | truthvalue | read-write |
Sets/Gets redundancy mode on on/off line state. |
freqs | 1.3.6.1.4.1.23304.2.1.1.4 | |||
rfFreq | 1.3.6.1.4.1.23304.2.1.1.4.1 | integer | read-write |
Sets/Gets the RBUC RF frequency. |
ifFreq | 1.3.6.1.4.1.23304.2.1.1.4.2 | integer | read-write |
Sets/Gets the RBUC IF frequency. |
loFreq | 1.3.6.1.4.1.23304.2.1.1.4.3 | integer | read-write |
Sets/Gets the RBUC LO frequency. |
misc | 1.3.6.1.4.1.23304.2.1.1.5 | |||
serIf | 1.3.6.1.4.1.23304.2.1.1.5.1 | displaystring | read-write |
Sets/Gets serial interface - rate, length, parity, stop, terminate RS422/485. |
serEcho | 1.3.6.1.4.1.23304.2.1.1.5.2 | truthvalue | read-write |
Sets/Gets serial interface echo on/off. |
pwrAlarmThresh | 1.3.6.1.4.1.23304.2.1.1.5.3 | displaystring | read-write |
Sets/Gets power alarm threshold. |
burstPwrThresh | 1.3.6.1.4.1.23304.2.1.1.5.4 | displaystring | read-write |
Sets/Gets burst power threshold. |
refSource | 1.3.6.1.4.1.23304.2.1.1.5.5 | truthvalue | read-write |
Sets/Gets reference source 0-external, 1-internal. |
ledState | 1.3.6.1.4.1.23304.2.1.1.5.6 | truthvalue | read-write |
SetS/Gets LEDs status on/off. |
status | 1.3.6.1.4.1.23304.2.1.2 | |||
paStatus | 1.3.6.1.4.1.23304.2.1.2.1 | integer | read-only |
Gets to 1 when PA is on. Enumeration: 'on': 1, 'off': 0. |
txPower | 1.3.6.1.4.1.23304.2.1.2.2 | displaystring | read-only |
Gets Tx power format x.x dB. |
txBurstPower | 1.3.6.1.4.1.23304.2.1.2.3 | displaystring | read-only |
Gets Tx power. Format is x.x,y.y,z.z, where x.x is current burst power, y.y is min and z.z is max burts power. |
faults | 1.3.6.1.4.1.23304.2.1.2.4 | integer | read-only |
Gets the current fault status. Format - Bit0 PA fault, Bit1 Fan fault, Bit2 Power fault, Bit3 Temp fault, Bit4 10MHz fault, Bit5 Internal fault Bit6 LNB fault, Bit7 Red'cy Cont fault. |
latchedFaults | 1.3.6.1.4.1.23304.2.1.2.5 | integer | read-only |
Gets the current latched faults. Format is same as Faults. |
temperature | 1.3.6.1.4.1.23304.2.1.2.6 | displaystring | read-only |
Gets the BUC temperature. Format is x.x. |
minMaxTemperature | 1.3.6.1.4.1.23304.2.1.2.7 | displaystring | read-only |
Gets the BUC temperature. Format is x.x,y.y where x.x is max and y.y is min temperature. |
systemSetting | 1.3.6.1.4.1.23304.2.1.2.8 | integer | read-only |
Gets the current system status. Format is Bit0 - PA state, Bit1 - RS232 Tx, Bit2 - FSK Tx, Bit3 - RS485 Tx Bit4 - Redundancy mode, Bit5 - Online, Bit6..Bit7 - Redundancy cold or hot mode, Bit8 - HTTP Tx, Bit9 - TELNET Tx, Bit10 - SNMP Tx. |
systemPoll | 1.3.6.1.4.1.23304.2.1.2.9 | integer | read-only |
Gets the system poll status. Format is Bit0 - Fault, Bit1 - System change. |
deviceType | 1.3.6.1.4.1.23304.2.1.2.10 | displaystring | read-only |
Gets the device type. Format is X,Y where X is the model and Y is software version. |
gateway | 1.3.6.1.4.1.23304.2.1.2.11 | displaystring | read-only |
Gets the BUC gateway address. |
ipAddr | 1.3.6.1.4.1.23304.2.1.2.12 | displaystring | read-only |
Gets the BUC IP address. |
macAddress | 1.3.6.1.4.1.23304.2.1.2.13 | displaystring | read-only |
Gets the BUC MAC address. |
netmask | 1.3.6.1.4.1.23304.2.1.2.14 | displaystring | read-only |
Gets the BUC netmask. |
refPower | 1.3.6.1.4.1.23304.2.1.2.15 | displaystring | read-only |
Gets the BUC reference power. |
bucConfiguration | 1.3.6.1.4.1.23304.2.1.2.16 | displaystring | read-only |
Gets the BUC configuration. |
buildStandard | 1.3.6.1.4.1.23304.2.1.2.17 | displaystring | read-only |
Gets the BUC build standard. |
info | 1.3.6.1.4.1.23304.2.1.3 | |||
idInfo | 1.3.6.1.4.1.23304.2.1.3.1 | displaystring | read-only |
Gets the module firmware revision, serial number and model. This string will have a zero length if the revision is unknown. |
limits | 1.3.6.1.4.1.23304.2.1.3.2 | displaystring | read-only |
Gets the limit data for the BUC. Format is: Power meter MIN/MAX , IF,RF and LO frequencies. This string will have a zero length if the revision is unknown. |
pktProtocolsInfo | 1.3.6.1.4.1.23304.2.1.3.3 | displaystring | read-only |
Gets supported packet protocols and the corresponding address ranges. |