RBUC-MIB: View SNMP OID List / Download MIB

VENDOR: CODAN LIMITED


 Home MIB: RBUC-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 rbucMIB 1.3.6.1.4.1.23304.2.1
The Structure of Management Information for the Codan enterprise. Copyright(c) 2009 All rights reserved
     configuration 1.3.6.1.4.1.23304.2.1.1
         txSettings 1.3.6.1.4.1.23304.2.1.1.1
             txOn 1.3.6.1.4.1.23304.2.1.1.1.1 integer read-write
Sets Tx on/off.
             txDefault 1.3.6.1.4.1.23304.2.1.1.1.2 truthvalue read-write
Sets Tx default 1-last 0-off.
             txAttenuator 1.3.6.1.4.1.23304.2.1.1.1.3 integer read-write
Sets/Gets Tx attenuation value in 1dBm steps.
         pktProtocol 1.3.6.1.4.1.23304.2.1.1.2
             protocol 1.3.6.1.4.1.23304.2.1.1.2.1 integer read-write
Sets/Gets packet protocol 0 - ASCII, 1 - CODAN, 2 - .
             address 1.3.6.1.4.1.23304.2.1.1.2.2 integer read-write
Sets/Gets packet address: 0-31 NDSatcom ...
         rcSetting 1.3.6.1.4.1.23304.2.1.1.3
             mode 1.3.6.1.4.1.23304.2.1.1.3.1 integer read-write
Sets/Gets redundancy mode 0-none, 1-warm, 2-hot.
             onLine 1.3.6.1.4.1.23304.2.1.1.3.2 truthvalue read-write
Sets/Gets redundancy mode on on/off line state.
         freqs 1.3.6.1.4.1.23304.2.1.1.4
             rfFreq 1.3.6.1.4.1.23304.2.1.1.4.1 integer read-write
Sets/Gets the RBUC RF frequency.
             ifFreq 1.3.6.1.4.1.23304.2.1.1.4.2 integer read-write
Sets/Gets the RBUC IF frequency.
             loFreq 1.3.6.1.4.1.23304.2.1.1.4.3 integer read-write
Sets/Gets the RBUC LO frequency.
         misc 1.3.6.1.4.1.23304.2.1.1.5
             serIf 1.3.6.1.4.1.23304.2.1.1.5.1 displaystring read-write
Sets/Gets serial interface - rate, length, parity, stop, terminate RS422/485.
             serEcho 1.3.6.1.4.1.23304.2.1.1.5.2 truthvalue read-write
Sets/Gets serial interface echo on/off.
             pwrAlarmThresh 1.3.6.1.4.1.23304.2.1.1.5.3 displaystring read-write
Sets/Gets power alarm threshold.
             burstPwrThresh 1.3.6.1.4.1.23304.2.1.1.5.4 displaystring read-write
Sets/Gets burst power threshold.
             refSource 1.3.6.1.4.1.23304.2.1.1.5.5 truthvalue read-write
Sets/Gets reference source 0-external, 1-internal.
             ledState 1.3.6.1.4.1.23304.2.1.1.5.6 truthvalue read-write
SetS/Gets LEDs status on/off.
     status 1.3.6.1.4.1.23304.2.1.2
         paStatus 1.3.6.1.4.1.23304.2.1.2.1 integer read-only
Gets to 1 when PA is on. Enumeration: 'on': 1, 'off': 0.
         txPower 1.3.6.1.4.1.23304.2.1.2.2 displaystring read-only
Gets Tx power format x.x dB.
         txBurstPower 1.3.6.1.4.1.23304.2.1.2.3 displaystring read-only
Gets Tx power. Format is x.x,y.y,z.z, where x.x is current burst power, y.y is min and z.z is max burts power.
         faults 1.3.6.1.4.1.23304.2.1.2.4 integer read-only
Gets the current fault status. Format - Bit0 PA fault, Bit1 Fan fault, Bit2 Power fault, Bit3 Temp fault, Bit4 10MHz fault, Bit5 Internal fault Bit6 LNB fault, Bit7 Red'cy Cont fault.
         latchedFaults 1.3.6.1.4.1.23304.2.1.2.5 integer read-only
Gets the current latched faults. Format is same as Faults.
         temperature 1.3.6.1.4.1.23304.2.1.2.6 displaystring read-only
Gets the BUC temperature. Format is x.x.
         minMaxTemperature 1.3.6.1.4.1.23304.2.1.2.7 displaystring read-only
Gets the BUC temperature. Format is x.x,y.y where x.x is max and y.y is min temperature.
         systemSetting 1.3.6.1.4.1.23304.2.1.2.8 integer read-only
Gets the current system status. Format is Bit0 - PA state, Bit1 - RS232 Tx, Bit2 - FSK Tx, Bit3 - RS485 Tx Bit4 - Redundancy mode, Bit5 - Online, Bit6..Bit7 - Redundancy cold or hot mode, Bit8 - HTTP Tx, Bit9 - TELNET Tx, Bit10 - SNMP Tx.
         systemPoll 1.3.6.1.4.1.23304.2.1.2.9 integer read-only
Gets the system poll status. Format is Bit0 - Fault, Bit1 - System change.
         deviceType 1.3.6.1.4.1.23304.2.1.2.10 displaystring read-only
Gets the device type. Format is X,Y where X is the model and Y is software version.
         gateway 1.3.6.1.4.1.23304.2.1.2.11 displaystring read-only
Gets the BUC gateway address.
         ipAddr 1.3.6.1.4.1.23304.2.1.2.12 displaystring read-only
Gets the BUC IP address.
         macAddress 1.3.6.1.4.1.23304.2.1.2.13 displaystring read-only
Gets the BUC MAC address.
         netmask 1.3.6.1.4.1.23304.2.1.2.14 displaystring read-only
Gets the BUC netmask.
         refPower 1.3.6.1.4.1.23304.2.1.2.15 displaystring read-only
Gets the BUC reference power.
         bucConfiguration 1.3.6.1.4.1.23304.2.1.2.16 displaystring read-only
Gets the BUC configuration.
         buildStandard 1.3.6.1.4.1.23304.2.1.2.17 displaystring read-only
Gets the BUC build standard.
     info 1.3.6.1.4.1.23304.2.1.3
         idInfo 1.3.6.1.4.1.23304.2.1.3.1 displaystring read-only
Gets the module firmware revision, serial number and model. This string will have a zero length if the revision is unknown.
         limits 1.3.6.1.4.1.23304.2.1.3.2 displaystring read-only
Gets the limit data for the BUC. Format is: Power meter MIN/MAX , IF,RF and LO frequencies. This string will have a zero length if the revision is unknown.
         pktProtocolsInfo 1.3.6.1.4.1.23304.2.1.3.3 displaystring read-only
Gets supported packet protocols and the corresponding address ranges.