Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
           rbnOpticalTransceiverAlarm 1.3.6.1.4.1.2352.2.49.0.2
An rbnOpticalTransceiverAlarm notification signifies that an alarm has been raised or cleared on a Optical Transceiver
           rbnOpticalTransceiverLaneAlarm 1.3.6.1.4.1.2352.2.49.0.3
An rbnOpticalTransceiverLaneAlarm notification signifies that an alarm has been raised or cleared in a lane on a Optical Transceiver
           rbnOpticalTransceiverMonMIBGroups 1.3.6.1.4.1.2352.2.49.2.3
               rbnOpticalTransceiverMonMIBNotificationGroup 1.3.6.1.4.1.2352.2.49.2.3.2
A collection of notifications providing Optical Transceiver fault condition
           rbnOpticalTransceiverMonMIBCompliances 1.3.6.1.4.1.2352.2.49.2.4
               rbnOpticalTransceiverMonMIBCompliance 1.3.6.1.4.1.2352.2.49.2.4.1
The compliance statement for the OpticalTransceiver MIB
 rbnOpticalTransceiver 1.3.6.1.4.1.2352.2.50
The MIB used to manage the Optical Transceivers in Line Card ports in SSR
       rbnOpticalTransceiverDetails 1.3.6.1.4.1.2352.2.50.1
           rbnOpticalTransceiverPortTable 1.3.6.1.4.1.2352.2.50.1.1 no-access
This table contains the ports with optical transceivers and corresponding parameters
               rbnOpticalTransceiverPortEntry 1.3.6.1.4.1.2352.2.50.1.1.1 no-access
Line Card port optical transceiver parameter description.
                   rbnOpticalTransceiverCardSlot 1.3.6.1.4.1.2352.2.50.1.1.1.1 rbnslot read-only
The chassis slot number in which the card is present where the Optical Transceiver plugged in.
                   rbnOpticalTransceiverPort 1.3.6.1.4.1.2352.2.50.1.1.1.2 rbnport read-only
The port number where the Optical Transceiver plugged in.
                   rbnOpticalTransceiverType 1.3.6.1.4.1.2352.2.50.1.1.1.3 octet string read-only
Type and category of Optical Transceiver
                   rbnOpticalTransceiverMediaType 1.3.6.1.4.1.2352.2.50.1.1.1.4 octet string read-only
Optical Transceiver Media Type
                   rbnOpticalTransceiverRbnEricssonApproved 1.3.6.1.4.1.2352.2.50.1.1.1.5 truthvalue read-only
Is the Optical Transceiver n this port approved by Ericsson, Yes/No?
                   rbnOpticalTransceiverDiagMonitoring 1.3.6.1.4.1.2352.2.50.1.1.1.6 truthvalue read-only
Is Optical Transceiver Diag Monitoring On or Off?
                   rbnOpticalTransceiverCLEIcode 1.3.6.1.4.1.2352.2.50.1.1.1.7 octet string read-only
Optical Transceiver Common Language Equipment Identifier (CLEI) code.
                   rbnOpticalTransceiverSerialNo 1.3.6.1.4.1.2352.2.50.1.1.1.8 octet string read-only
Optical Transceiver serial number
                   rbnOpticalTransceiverFrequency 1.3.6.1.4.1.2352.2.50.1.1.1.9 octet string read-only
Optical Transceiver Frequency
                   rbnOpticalTransceiverWaveLength 1.3.6.1.4.1.2352.2.50.1.1.1.10 rbnopticaltransceiverparamwavelength read-only
Optical Transceiver Wave Length
                   rbnOpticalTransceiverAdditionalFeatures 1.3.6.1.4.1.2352.2.50.1.1.1.11 octet string read-only
Optical Transceiver Additional Features such as, Is Optical Transceiver OTN capable? and/or Is Optical Transceiver Tunable?
                   rbnOpticalTransceiverFrequencyStart 1.3.6.1.4.1.2352.2.50.1.1.1.12 octet string read-only
Frequency Start for tunable optical transceiver. Not applicable if optical transceiver is not tunable
                   rbnOpticalTransceiverFrequencyEnd 1.3.6.1.4.1.2352.2.50.1.1.1.13 octet string read-only
Frequency End for tunable optical transceiver. Not applicable if optical transceiver is not tunable
                   rbnOpticalTransceiverFrequencySpacing 1.3.6.1.4.1.2352.2.50.1.1.1.14 octet string read-only
Frequency Spacing for tunable optical transceiver. Not applicable if optical transceiver is not tunable
                   rbnOpticalTransceiverOTNFramer 1.3.6.1.4.1.2352.2.50.1.1.1.15 octet string read-only
Framer of OTN if optical transceiver is OTN capable. Not applicable if optical transceiver is not OTN capable
                   rbnOpticalTransceiverOTNFEC 1.3.6.1.4.1.2352.2.50.1.1.1.16 octet string read-only
FEC of OTN if optical transceiver is OTN capable. Not applicable if optical transceiver is not OTN capable
                   rbnOpticalTransceiverPowerLevel 1.3.6.1.4.1.2352.2.50.1.1.1.17 octet string read-only
Optical Transceiver Power Level
                   rbnOpticalTransceiverActiveAlarmCount 1.3.6.1.4.1.2352.2.50.1.1.1.18 integer read-only
Number of alarms active on the Optical Transceiver
                   rbnOpticalTransceiverParamBitMask 1.3.6.1.4.1.2352.2.50.1.1.1.19 integer32 read-only
This Bit Mask indicates which values are valid for RbnOpticalTransceiverParamType in rbnOpticalTransceiverParamTable: 0x0001 optical transceiver txpower valid 0x0002 optical transceiver rxpower valid 0x0004 optical transceiver temperature valid 0x0008 optical transceiver laserBiasCurrent valid 0x0010 optical transceiver soaBiasCurrent valid 0x0020 optical transceiver Vcc valid 0x0040 optical transceiver aux1 valid 0x0080 optical transceiver aux2 valid 0x0100 optical transceiver lane txpower valid 0x0200 optical transceiver lane rxpower valid 0x0400 optical transceiver lane temperature valid 0x0800 optical transceiver lane laserBiasCurrent valid
                   rbnOpticalTransceiverLaneCount 1.3.6.1.4.1.2352.2.50.1.1.1.20 integer read-only
Number of Lanes in optical transceiver
           rbnOpticalTransceiverParamTable 1.3.6.1.4.1.2352.2.50.1.2 no-access
This table provides objects to monitor optical transceiver parameters in a network element. It also provides objects for monitoring high and low warning and alarm threshold on these monitored parameters.
               rbnOpticalTransceiverParamEntry 1.3.6.1.4.1.2352.2.50.1.2.1 no-access
OpticalTransceiver Parameter Entries in Table
                   rbnOpticalTransceiverParamType 1.3.6.1.4.1.2352.2.50.1.2.1.1 rbnopticaltransceiverparamtype read-only
This object specifies the optical parameter type that is being monitored in this entry.
                   rbnOpticalTransceiverParamDescription 1.3.6.1.4.1.2352.2.50.1.2.1.2 octet string read-only
This object specifies the optical parameter description including units that is being monitored in this entry.
                   rbnOpticalTransceiverCurrentValue 1.3.6.1.4.1.2352.2.50.1.2.1.3 rbnopticaltransceiverparametervalue read-only
The current value of tx power, rx power, temperature, bias current and Vcc
                   rbnOpticalTransceiverMaxAlarmValue 1.3.6.1.4.1.2352.2.50.1.2.1.4 rbnopticaltransceiverparametervalue read-only
The alarm high threshold value of tx power, rx power, temperature, bias current and Vcc
                   rbnOpticalTransceiverMaxWarningValue 1.3.6.1.4.1.2352.2.50.1.2.1.5 rbnopticaltransceiverparametervalue read-only
The warning high threshold value of tx power, rx power, temperature, bias current and Vcc
                   rbnOpticalTransceiverMinAlarmValue 1.3.6.1.4.1.2352.2.50.1.2.1.6 rbnopticaltransceiverparametervalue read-only
The alarm low threshold value of tx power, rx power, temperature, bias current and Vcc
                   rbnOpticalTransceiverMinWarningValue 1.3.6.1.4.1.2352.2.50.1.2.1.7 rbnopticaltransceiverparametervalue read-only
The warning low threshold value of tx power, rx power, temperature, bias current and Vcc
           rbnLaneInOpticalTransceiverParamTable 1.3.6.1.4.1.2352.2.50.1.3 no-access
This table provides objects to monitor optical transceiver parameters in a network element. It also provides objects for monitoring high and low warning and alarm threshold on these monitored parameters.
               rbnLaneInOpticalTransceiverParamEntry 1.3.6.1.4.1.2352.2.50.1.3.1 no-access
LaneInOpticalTransceiver Parameter Entries in Table
                   rbnLaneInOpticalTransceiver 1.3.6.1.4.1.2352.2.50.1.3.1.1 integer32 read-only
This object specifies the optical transceiver lane that is being monitored in this entry.
                   rbnLaneInOpticalTransceiverParamType 1.3.6.1.4.1.2352.2.50.1.3.1.2 rbnlaneinopticaltransceiverparamtype read-only
This object specifies the optical parameter type that is being monitored in this entry.
                   rbnLaneInOpticalTransceiverCurrentValue 1.3.6.1.4.1.2352.2.50.1.3.1.3 rbnlaneinopticaltransceiverparametervalue read-only
The current value of tx power, rx power, temperature, bias current and Vcc
                   rbnLaneInOpticalTransceiverMaxAlarmValue 1.3.6.1.4.1.2352.2.50.1.3.1.4 rbnlaneinopticaltransceiverparametervalue read-only
The alarm high threshold value of tx power, rx power, temperature, bias current and Vcc
                   rbnLaneInOpticalTransceiverMaxWarningValue 1.3.6.1.4.1.2352.2.50.1.3.1.5 rbnlaneinopticaltransceiverparametervalue read-only
The warning high threshold value of tx power, rx power, temperature, bias current and Vcc
                   rbnLaneInOpticalTransceiverMinAlarmValue 1.3.6.1.4.1.2352.2.50.1.3.1.6 rbnlaneinopticaltransceiverparametervalue read-only
The alarm low threshold value of tx power, rx power, temperature, bias current and Vcc
                   rbnLaneInOpticalTransceiverMinWarningValue 1.3.6.1.4.1.2352.2.50.1.3.1.7 rbnlaneinopticaltransceiverparametervalue read-only
The warning low threshold value of tx power, rx power, temperature, bias current and Vcc