Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 ptRadioLink 1.3.6.1.4.1.18086.7
This is the MIB for Radio Link specifics in PT
     ctTable 1.3.6.1.4.1.18086.7.1 no-access
A table of CT Table entries.
         ctEntry 1.3.6.1.4.1.18086.7.1.1 no-access
An entry of CT application.
             actualInputPower 1.3.6.1.4.1.18086.7.1.1.1 octet string read-only
Actual input power of the CT in dBm
             actualOutputPower 1.3.6.1.4.1.18086.7.1.1.2 octet string read-only
Actual output power of the CT in dBm
             actualRxAcm 1.3.6.1.4.1.18086.7.1.1.3 octet string read-only
Actual rx modulation and coding
             actualTxAcm 1.3.6.1.4.1.18086.7.1.1.4 octet string read-only
Actual tx modulation and coding
             ctDistinguishedName 1.3.6.1.4.1.18086.7.1.1.5 octet string read-only
Unique id/name of the carrier termination, according to FDN (rack/slot/port/class)
             description 1.3.6.1.4.1.18086.7.1.1.6 octet string read-write
User description of the carrior termination.
             carrierId 1.3.6.1.4.1.18086.7.1.1.7 integer read-write
Id of the carrier. (A, B, C, D) Used in XPIC & MIMO configurations to check that the carrier termination is connected to the correct far end carrier termination. Should be the same id on both sides of the hop. Defaulted when not MIMO or XPIC. Sometimes also referred to as preamble Enumeration: 'a': 1, 'unknown': 5, 'c': 3, 'b': 2, 'd': 4.
             ctStatus 1.3.6.1.4.1.18086.7.1.1.8 integer read-only
The status of the carrier termination, hop Enumeration: 'down': 1, 'na': 3, 'degraded': 5, 'up': 2, 'unknown': 4.
             frameId 1.3.6.1.4.1.18086.7.1.1.9 integer32 read-write
A unique identifier for the radio frame to be used. Wanted frameId, txFrequency, rxFrequency, referenceSec, selectedMinAcm and selectedMaxAcm must be a valid combination.
             txFrequency 1.3.6.1.4.1.18086.7.1.1.10 integer32 read-write
Selected frequency on the transmitter (kHz). Wanted frameId, txFrequency, rxFrequency, referenceSec, selectedMinAcm and selectedMaxAcm must be a valid combination.
             minTxFrequency 1.3.6.1.4.1.18086.7.1.1.11 integer32 read-only
Minimum Tx frequency possible to use, given by the selected frame-id
             maxTxFrequency 1.3.6.1.4.1.18086.7.1.1.12 integer32 read-only
Maximum Tx frequency possible to use, given by the selected frame-id
             rxFrequency 1.3.6.1.4.1.18086.7.1.1.13 integer32 read-write
Selected frequency on the receiver (kHz). Wanted frameId, txFrequency, rxFrequency, referenceSec, selectedMinAcm and selectedMaxAcm must be a valid combination.
             minRxFrequency 1.3.6.1.4.1.18086.7.1.1.14 integer32 read-only
Minimum Rx frequency possible to use, given by the selected frame-id
             maxRxFrequency 1.3.6.1.4.1.18086.7.1.1.15 integer32 read-only
Maximum Rx frequency possible to use, given by the selected frame-id
             frequencyStepSize 1.3.6.1.4.1.18086.7.1.1.16 integer32 read-only
Frequency step size in kHz
             duplexDistance 1.3.6.1.4.1.18086.7.1.1.17 integer32 read-only
Distance between Tx and Rx frequencies (kHz)
             duplexType 1.3.6.1.4.1.18086.7.1.1.18 integer read-only
The duplex type is given by the equipment (Fixed,Variable) Enumeration: 'variable': 1, 'unknown': 3, 'fixed': 2.
             duplexConfig 1.3.6.1.4.1.18086.7.1.1.19 enablestatustc read-write
Enabling or disabling configuration of Rx freq using duplex distance
             autoFreqSelection 1.3.6.1.4.1.18086.7.1.1.20 integer read-write
Automatic frequency selection mode Enumeration: 'disabled': 1, 'master': 2, 'slave': 3, 'unknown': 4.
             autoFreqSelectedChannel 1.3.6.1.4.1.18086.7.1.1.21 integer32 read-write
Automatic frequency selected channel
             autoFreqSelectionStatus 1.3.6.1.4.1.18086.7.1.1.22 integer read-only
Automatic frequency status Enumeration: 'waitingForChannelInfoRequest': 5, 'unknown': 10, 'requestingInfoFromSlave': 3, 'searchingForSlave': 2, 'failed': 9, 'finished': 8, 'initializing': 7, 'waitingForMaster': 4, 'inProgress': 6, 'idle': 1.
             channelSpacing 1.3.6.1.4.1.18086.7.1.1.23 integer read-only
Channel spacing Enumeration: 'cs100MHz': 14, 'cs80MHz': 18, 'cs2000MHz': 24, 'cs1500MHz': 22, 'cs40MHz': 7, 'cs20MHz': 4, 'cs200MHz': 16, 'unknown': 25, 'cs250MHz': 10, 'cs750MHz': 13, 'cs1250MHz': 21, 'cs1000MHz': 20, 'cs62p5MHz': 23, 'cs50MHz': 8, 'cs112MHz': 19, 'cs10MHz': 2, 'cs14MHz': 3, 'cs28MHz': 5, 'cs125MHz': 17, 'cs60MHz': 11, 'cs7MHz': 1, 'cs500MHz': 12, 'cs56MHz': 9, 'cs150MHz': 15, 'cs30MHz': 6.
             polarization 1.3.6.1.4.1.18086.7.1.1.24 integer read-write
Antenna polarization Enumeration: 'unknown': 4, 'horizontal': 2, 'notSpecified': 1, 'vertical': 3.
             txOperStatus 1.3.6.1.4.1.18086.7.1.1.25 integer read-only
Operative status of the transmitter Enumeration: 'standby': 4, 'unknown': 1, 'off': 2, 'on': 3.
             txAdminStatus 1.3.6.1.4.1.18086.7.1.1.26 integer read-write
Administrative status of the transmitter Enumeration: 'on': 2, 'off': 1, 'unknown': 3.
             selectedOutputPowerType 1.3.6.1.4.1.18086.7.1.1.27 integer read-write
Selected output power type Enumeration: 'high': 2, 'unknown': 3, 'standard': 1.
             availableOutputPowerType 1.3.6.1.4.1.18086.7.1.1.28 integer read-write
Available output power type Enumeration: 'high': 2, 'unknown': 3, 'standard': 1.
             selectedMinOutputPower 1.3.6.1.4.1.18086.7.1.1.29 integer32 read-write
Selected min output power. Selected min & max output power should be set to the same value for RTPC mode, otherwise the hop operates in ATPC mode.
             selectedMaxOutputPower 1.3.6.1.4.1.18086.7.1.1.30 integer32 read-write
Selected max output power. Selected min & max output power should be set to the same value for RTPC mode, otherwise the hop operates in ATPC mode.
             availableMinOutputPower 1.3.6.1.4.1.18086.7.1.1.31 integer32 read-only
The minimum output power supported (dBm). The system shows a value if the equipment is available and a frame id has been selected.
             availableMaxOutputPower 1.3.6.1.4.1.18086.7.1.1.32 integer32 read-only
The maximum output power supported (dBm). The system shows a value if the equipment is available and a frame id has been selected.
             referenceSec 1.3.6.1.4.1.18086.7.1.1.33 integer read-write
Each modulation is compliant to a Reference Spectrum Efficiency Class (RSEC). When running Adaptive Coding/Modulation, one SEC has to be selected for all the coding/modulations between selectedMinACM and selectedMaxACM. This parameter is called Reference SEC. This setting will affect availableMaxOutputPower, in order to fulfill spectrum requirements. Wanted frameId, txFrequency, rxFrequency, referenceSec, selectedMinAcm and selectedMaxAcm must be a valid combination. Enumeration: 'noAvailable': 1, 'unknown': 15, 'sec5B': 7, 'sec5HB': 11, 'sec5LB': 10, 'sec7B': 14, 'sec2': 2, 'sec6B': 9, 'sec6HB': 13, 'sec4L': 4, 'sec6LB': 12, 'sec4H': 5.
             targetInputPowerFarEnd 1.3.6.1.4.1.18086.7.1.1.34 integer32 read-write
The wanted input power at far end (dBm), when running ATPC
             berAlarmThreshold 1.3.6.1.4.1.18086.7.1.1.35 integer read-write
Threshold for the BER alarm Enumeration: 'tenExpMinus6': 1, 'tenExpMinus3': 2.
             inputPowerAlarmThreshold 1.3.6.1.4.1.18086.7.1.1.36 integer32 read-write
Threshold for the input power alarm
             plannedAlignmentInputPower 1.3.6.1.4.1.18086.7.1.1.37 integer32 read-write
The planned received input power (dBm) dependent upon selected minimum ACM and corresponding output power. Used when doing alignment
             atpcFallback 1.3.6.1.4.1.18086.7.1.1.38 enablestatustc read-write
Enable or disable the output power fall back function
             atpcFallbackTimer 1.3.6.1.4.1.18086.7.1.1.39 integer32 read-write
Specifies the timer for output power fall back (# of seconds)
             atpcFallbackOutputPower 1.3.6.1.4.1.18086.7.1.1.40 integer32 read-write
The ATPC fallback output power
             xpicStatus 1.3.6.1.4.1.18086.7.1.1.41 xpicmimotc read-only
Status of the XPIC function.
             mimoStatus 1.3.6.1.4.1.18086.7.1.1.42 xpicmimotc read-only
Status of the MIMO function.
             actualSnir 1.3.6.1.4.1.18086.7.1.1.43 octet string read-only
Actual signal to noise plus interference ratio (dB).
             actualXpi 1.3.6.1.4.1.18086.7.1.1.44 octet string read-only
The carrier to cross-polar interference level (dBc).
             actualSi 1.3.6.1.4.1.18086.7.1.1.45 octet string read-only
Spatial interference between the CTs when MIMO is configured.
             actualTxCapacity 1.3.6.1.4.1.18086.7.1.1.46 integer32 read-only
Actual capacity supported by the carrier termination.
             licensedCapacity 1.3.6.1.4.1.18086.7.1.1.47 integer32 read-only
Wanted or installed license for the capacity allowed for the carrier termination.
             availableMinCapacity 1.3.6.1.4.1.18086.7.1.1.48 integer32 read-only
Minimum capacity possible to use. Given by the selected frame-id (kbit/s)
             availableMaxCapacity 1.3.6.1.4.1.18086.7.1.1.49 integer32 read-only
Maximum capacity possible to use. Given by the selected frame-id (kbit/s)
             selectedMinCapacity 1.3.6.1.4.1.18086.7.1.1.50 integer32 read-only
Selected minimum capacity, derived from selected minimum ACM (kbit/s)
             selectedMaxCapacity 1.3.6.1.4.1.18086.7.1.1.51 integer32 read-only
Selected maximum capacity, derived from selected maximum ACM (kbit/s)
             wantedLicensedCapacity 1.3.6.1.4.1.18086.7.1.1.52 integer32 read-write
Wanted licensed capacity and creation of LRF for the carrier termination (kbit/s)
             availableMinAcm 1.3.6.1.4.1.18086.7.1.1.53 acmtc read-only
Minimum ACM possible to use, given by the selected frame id.
             availableMaxAcm 1.3.6.1.4.1.18086.7.1.1.54 acmtc read-only
Maximum ACM possible to use, given by the selected frame id
             selectedMinAcm 1.3.6.1.4.1.18086.7.1.1.55 acmtc read-write
Selected minimum coding/modulation. If selectedMinACM = selectedMaxACM, then the modulation is fixed
             selectedMaxAcm 1.3.6.1.4.1.18086.7.1.1.56 acmtc read-write
Selected maximum coding/modulation. If selectedMinACM = selectedMaxACM, then the modulation is fixed
             actualRxAcmTC 1.3.6.1.4.1.18086.7.1.1.57 acmtc read-only
Actual rx modulation and coding
             actualTxAcmTC 1.3.6.1.4.1.18086.7.1.1.58 acmtc read-only
Actual tx modulation and coding
             alignmentMode 1.3.6.1.4.1.18086.7.1.1.59 enablestatustc read-write
Enable or disable the alignment mode
             rfLoop 1.3.6.1.4.1.18086.7.1.1.60 enablestatustc read-write
Enable or disable the rf loop
     ptRadioLinkConformance 1.3.6.1.4.1.18086.7.2
         ptRadioLinkCompliances 1.3.6.1.4.1.18086.7.2.1
             ptRadioLinkFullCompliance 1.3.6.1.4.1.18086.7.2.1.1
The compliance statement for SNMP entities which implement everything.
         ptRadioLinkGroups 1.3.6.1.4.1.18086.7.2.2
             ptRadioLinkCompleteGroup 1.3.6.1.4.1.18086.7.2.2.1
A collection of all current objects in this MIB module.
     rltTable 1.3.6.1.4.1.18086.7.3 no-access
A table of RLT Table entries.
         rltEntry 1.3.6.1.4.1.18086.7.3.1 no-access
An entry of RLT application.
             rltDistinguishedName 1.3.6.1.4.1.18086.7.3.1.1 octet string read-only
Unique id/name of the radio link termination, according to FDN (rack/slot/port/class)
             neIpAddress 1.3.6.1.4.1.18086.7.3.1.2 ipaddress read-only
NE IP address
             neIpv6Address 1.3.6.1.4.1.18086.7.3.1.3 inetaddressipv6 read-only
NE IP V6 address
             neName 1.3.6.1.4.1.18086.7.3.1.4 octet string read-only
NE Name
             neType 1.3.6.1.4.1.18086.7.3.1.5 integer read-only
NE Type Enumeration: 'cn': 5, 'pt': 6, 'mle': 2, 'unknown': 1, 'xfMle': 3, 'tn': 4.
             id 1.3.6.1.4.1.18086.7.3.1.6 octet string read-write
User defined id of the radio link terminal
             rltStatus 1.3.6.1.4.1.18086.7.3.1.7 integer read-only
The status of the radio link terminal Enumeration: 'down': 1, 'na': 3, 'degraded': 5, 'up': 2, 'unknown': 4.
             mode 1.3.6.1.4.1.18086.7.3.1.8 integer read-write
The status of the radio link terminal Enumeration: 'notAvailable22': 22, 'mode3plus3RLP': 17, 'mode1plus1RLP': 3, 'notAvailable11': 11, 'notAvailable13': 13, 'notAvailable12': 12, 'notAvailable14': 14, 'mode4plus0RLB': 10, 'mode2plus1CSB': 5, 'mode1plus1CSB': 2, 'unknown': 35, 'mode3plus1RLP': 15, 'mode2plus0RLB': 4, 'mode4plus1CSB': 31, 'mode4plus2CSB': 32, 'mode4plus4RLP': 21, 'mode3plus1CSB': 28, 'mode3plus0RLB': 9, 'mode2plus1RLP': 6, 'mode3plus2RLP': 16, 'notAvailable24': 24, 'notAvailable25': 25, 'notAvailable26': 26, 'notAvailable27': 27, 'mode4plus2RLP': 19, 'notAvailable23': 23, 'mode2plus2CSB': 7, 'mode3plus2CSB': 29, 'mode2plus2RLP': 8, 'mode4plus1RLP': 18, 'mode1plus0': 1, 'mode3plus3CSB': 30, 'mode4plus3CSB': 33, 'mode4plus4CSB': 34, 'mode4plus3RLP': 20.
             actualTxTotalCapacity 1.3.6.1.4.1.18086.7.3.1.9 integer32 read-only
Actual aggregated total (packet + TDM) transmitter capacity for the radio link termination. Limited by licenses & configuration (=nearEndLimitedCapacity) and depending on actual modulation/coding used at the moment.
             limitedTotalCapacity 1.3.6.1.4.1.18086.7.3.1.10 integer32 read-only
Maximum total capacity allowed by the current configuration and installed licenses. Aggregated from the constituent carrier termination values.
             protectionStatus 1.3.6.1.4.1.18086.7.3.1.11 integer read-only
Status of a protected node. Enumeration: 'unknown': 4, 'unprotected': 1, 'protected': 2, 'unableToProtect': 3.
             revertiveWaitToRestore 1.3.6.1.4.1.18086.7.3.1.12 integer32 read-write
The time, in number of seconds, to wait before switching back to the preferred Tx.
             revertivePreferredTx 1.3.6.1.4.1.18086.7.3.1.13 integer read-write
The preferred carrier termination transmitter. Enumeration: 'ct12': 2, 'ct11': 1, 'unknown': 6, 'notApplicable': 5, 'ct22': 4, 'ct21': 3.
             protectionSwitchMode 1.3.6.1.4.1.18086.7.3.1.14 integer read-write
.The mode in which the switching mechanism is configured Enumeration: 'auto': 1, 'manual': 2, 'unknown': 4, 'autoAndRevertive': 3, 'notApplicable': 5.
             fadeNotificationTimer 1.3.6.1.4.1.18086.7.3.1.15 integer32 read-write
Notification is sent if fading is longer than this timer, applicable for protection.
             expectedFarEndId 1.3.6.1.4.1.18086.7.3.1.16 octet string read-write
Expected id of far-end terminal
             farEndIdCheck 1.3.6.1.4.1.18086.7.3.1.17 integer read-write
Enabling of far end id check. Enumeration: 'disabled': 2, 'unknown': 3, 'enabled': 1.
             cpriMode 1.3.6.1.4.1.18086.7.3.1.18 integer read-write
Set the mode of the CPRI front-haul product. Enumeration: 'master': 1, 'notApplicable': 3, 'slave': 2, 'unknown': 4.
             cpriStatus 1.3.6.1.4.1.18086.7.3.1.19 integer read-only
The status of the CPRI front-haul product. Enumeration: 'unknown': 7, 'waitingOnCpri': 3, 'inSync': 6, 'idle': 1, 'waitingOnRxRequest': 4, 'waitingOnTxRequest': 5, 'waitingOnRtcSync': 2.
             manualSwitch 1.3.6.1.4.1.18086.7.3.1.20 integer read-write
Manual switch of protected carrier termination transmitter. Enumeration: 'ct12': 2, 'ct11': 1, 'unknown': 6, 'notApplicable': 5, 'ct22': 4, 'ct21': 3.
             mlhcOperStatus 1.3.6.1.4.1.18086.7.3.1.21 integer read-only
Operative status of multi layer header compression. Enumeration: 'down': 2, 'unknown': 3, 'up': 1.
             mlhcAdminStatus 1.3.6.1.4.1.18086.7.3.1.22 integer read-write
Administrative status of multi layer header compression. Enumeration: 'on': 2, 'off': 1, 'unknown': 3.
             mlhcMplsConfig 1.3.6.1.4.1.18086.7.3.1.23 integer read-write
MLHC/MPLS configuration. Enumeration: 'controlWord': 1, 'l2': 2, 'l3': 3, 'mplsOnly': 4, 'unknown': 5.
             plcOperStatus 1.3.6.1.4.1.18086.7.3.1.24 integer read-only
Operative status of payload compression. Enumeration: 'down': 2, 'unknown': 3, 'up': 1.
             plcAdminStatus 1.3.6.1.4.1.18086.7.3.1.25 integer read-write
Administrative status of payload compression. Enumeration: 'on': 2, 'off': 1, 'unknown': 3.
     ctPerformance 1.3.6.1.4.1.18086.7.4
         ctG826ContinuousTable 1.3.6.1.4.1.18086.7.4.1 no-access
A table of CT G826 Performance Continuous counters entries. The counters are reset by ctG826Reset
             ctG826ContinuousEntry 1.3.6.1.4.1.18086.7.4.1.1 no-access
An entry of CT G826 Performance Continuous counters.
                 ctG826TimeElapsed 1.3.6.1.4.1.18086.7.4.1.1.1 counter32 read-only
Time elapsed in seconds since last PMReset
                 ctBBE 1.3.6.1.4.1.18086.7.4.1.1.2 counter32 read-only
Background Block Errors
                 ctBBER 1.3.6.1.4.1.18086.7.4.1.1.3 octet string read-only
Background Block Errors Ratio
                 ctES 1.3.6.1.4.1.18086.7.4.1.1.4 counter32 read-only
Error seconds
                 ctESR 1.3.6.1.4.1.18086.7.4.1.1.5 octet string read-only
Error seconds Ratio
                 ctSES 1.3.6.1.4.1.18086.7.4.1.1.6 counter32 read-only
Severely error seconds
                 ctSESR 1.3.6.1.4.1.18086.7.4.1.1.7 octet string read-only
Severely error seconds Ratio
                 ctBB 1.3.6.1.4.1.18086.7.4.1.1.8 octet string read-only
Background blocks
                 ctUAS 1.3.6.1.4.1.18086.7.4.1.1.9 counter32 read-only
Unavailable seconds
                 ctG826Reset 1.3.6.1.4.1.18086.7.4.1.1.10 integer read-write
Reset the continuous PM counters Enumeration: 'reset': 3, 'other': 1, 'noReset': 2.
         ctG826Current15mTable 1.3.6.1.4.1.18086.7.4.2 no-access
A table of CT Performance G826 15 m current counters Table entries.
             ctG826Current15mEntry 1.3.6.1.4.1.18086.7.4.2.1 no-access
An entry of CT Performance G826 15 m current Table counters.
                 ctG826Current15mTimeElapsed 1.3.6.1.4.1.18086.7.4.2.1.1 counter32 read-only
Time elapsed in seconds since last PMReset
                 ctCurrent15mBBE 1.3.6.1.4.1.18086.7.4.2.1.2 counter32 read-only
Background Block Errors
                 ctCurrent15mBBER 1.3.6.1.4.1.18086.7.4.2.1.3 octet string read-only
Background Block Errors Ratio
                 ctCurrent15mES 1.3.6.1.4.1.18086.7.4.2.1.4 counter32 read-only
Error seconds
                 ctCurrent15mESR 1.3.6.1.4.1.18086.7.4.2.1.5 octet string read-only
Error seconds Ratio
                 ctCurrent15mSES 1.3.6.1.4.1.18086.7.4.2.1.6 counter32 read-only
Severely error seconds
                 ctCurrent15mSESR 1.3.6.1.4.1.18086.7.4.2.1.7 octet string read-only
Severely error seconds Ratio
                 ctCurrent15mBB 1.3.6.1.4.1.18086.7.4.2.1.8 counter32 read-only
Background blocks
                 ctCurrent15mUAS 1.3.6.1.4.1.18086.7.4.2.1.9 counter32 read-only
Unavailable seconds
         ctG826Current24hTable 1.3.6.1.4.1.18086.7.4.3 no-access
A table of CT Performance G826 Current 24h counters entries.
             ctG826Current24hEntry 1.3.6.1.4.1.18086.7.4.3.1 no-access
An entry of CT Performance G826 Current 24 h counters.
                 ctG826Current24hTimeElapsed 1.3.6.1.4.1.18086.7.4.3.1.1 counter32 read-only
Time elapsed in seconds since last PMReset
                 ctCurrent24hBBE 1.3.6.1.4.1.18086.7.4.3.1.2 counter32 read-only
Background Block Errors
                 ctCurrent24hBBER 1.3.6.1.4.1.18086.7.4.3.1.3 octet string read-only
Background Block Errors Ratio
                 ctCurrent24hES 1.3.6.1.4.1.18086.7.4.3.1.4 counter32 read-only
Error seconds
                 ctCurrent24hESR 1.3.6.1.4.1.18086.7.4.3.1.5 octet string read-only
Error seconds Ratio
                 ctCurrent24hSES 1.3.6.1.4.1.18086.7.4.3.1.6 counter32 read-only
Severely error seconds
                 ctCurrent24hSESR 1.3.6.1.4.1.18086.7.4.3.1.7 octet string read-only
Severely error seconds Ratio
                 ctCurrent24hBB 1.3.6.1.4.1.18086.7.4.3.1.8 counter32 read-only
Background blocks
                 ctCurrent24hUAS 1.3.6.1.4.1.18086.7.4.3.1.9 counter32 read-only
Unavailable seconds