PSA-WinSvsRaidTrap-MIB: View SNMP OID List / Download MIB
VENDOR: FUJITSU LIMITED
Home | MIB: PSA-WinSvsRaidTrap-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
fujitsu | 1.3.6.1.4.1.211 | |||
products | 1.3.6.1.4.1.211.1 | |||
iaServer | 1.3.6.1.4.1.211.1.31 | |||
primequest | 1.3.6.1.4.1.211.1.31.1 | |||
partition | 1.3.6.1.4.1.211.1.31.1.2 | |||
parititonVariables | 1.3.6.1.4.1.211.1.31.1.2.200 | |||
trapVarComInfo | 1.3.6.1.4.1.211.1.31.1.2.200.1 | |||
trapPartitionName | 1.3.6.1.4.1.211.1.31.1.2.200.1.1 | displaystring | no-access |
Partition name which trap is generated. |
trapPartitionId | 1.3.6.1.4.1.211.1.31.1.2.200.1.2 | integer | no-access |
Paritition identifier which trap is generated. |
trapEventLevel | 1.3.6.1.4.1.211.1.31.1.2.200.1.3 | displaystring | no-access |
Event level |
trapEventId | 1.3.6.1.4.1.211.1.31.1.2.200.1.4 | integer | no-access |
Event Identifier |
trapUnitName | 1.3.6.1.4.1.211.1.31.1.2.200.1.5 | displaystring | no-access |
Unit name which trap is generated. |
trapMmbVip | 1.3.6.1.4.1.211.1.31.1.2.200.1.6 | displaystring | no-access |
Management board vertual IP address. |
trapVarDivInfo | 1.3.6.1.4.1.211.1.31.1.2.200.2 | |||
trapPartNo | 1.3.6.1.4.1.211.1.31.1.2.200.2.1 | displaystring | no-access |
Parts number of trap source. |
trapStepping | 1.3.6.1.4.1.211.1.31.1.2.200.2.2 | displaystring | no-access |
|
trapSerialNo | 1.3.6.1.4.1.211.1.31.1.2.200.2.3 | displaystring | no-access |
Serial number of trap source. |
trapModelNo | 1.3.6.1.4.1.211.1.31.1.2.200.2.4 | displaystring | no-access |
Model number of trap source. |
trapSuspect | 1.3.6.1.4.1.211.1.31.1.2.200.2.5 | displaystring | no-access |
Logical name or pci bus number of trap source. |
trapVendorId | 1.3.6.1.4.1.211.1.31.1.2.200.2.6 | displaystring | no-access |
Vendor identifier of trap source. |
trapDeviceId | 1.3.6.1.4.1.211.1.31.1.2.200.2.7 | displaystring | no-access |
Device identifier of trap source. |
trapRevision | 1.3.6.1.4.1.211.1.31.1.2.200.2.8 | displaystring | no-access |
Revision of trap source. |
trapCardName | 1.3.6.1.4.1.211.1.31.1.2.200.2.9 | displaystring | no-access |
Device name of trap source. |
trapErrDetail | 1.3.6.1.4.1.211.1.31.1.2.200.2.10 | displaystring | no-access |
|
trapErrCode | 1.3.6.1.4.1.211.1.31.1.2.200.2.11 | displaystring | no-access |
|
trapIrpCode | 1.3.6.1.4.1.211.1.31.1.2.200.2.12 | displaystring | no-access |
|
trapHbaNo | 1.3.6.1.4.1.211.1.31.1.2.200.2.13 | integer | no-access |
|
trapErrCause | 1.3.6.1.4.1.211.1.31.1.2.200.2.14 | displaystring | no-access |
|
trapPathNo | 1.3.6.1.4.1.211.1.31.1.2.200.2.15 | integer | no-access |
|
trapDiskId | 1.3.6.1.4.1.211.1.31.1.2.200.2.16 | displaystring | no-access |
|
trapFmrDiskId | 1.3.6.1.4.1.211.1.31.1.2.200.2.17 | displaystring | no-access |
|
trapCurDiskId | 1.3.6.1.4.1.211.1.31.1.2.200.2.18 | displaystring | no-access |
|
trapPathId | 1.3.6.1.4.1.211.1.31.1.2.200.2.19 | displaystring | no-access |
|
trapPhysIf | 1.3.6.1.4.1.211.1.31.1.2.200.2.20 | displaystring | no-access |
|
trapVirtualIf | 1.3.6.1.4.1.211.1.31.1.2.200.2.21 | displaystring | no-access |
|
trapLogicalIp | 1.3.6.1.4.1.211.1.31.1.2.200.2.22 | displaystring | no-access |
|
trapWatchIp | 1.3.6.1.4.1.211.1.31.1.2.200.2.23 | displaystring | no-access |
|
trapInterface | 1.3.6.1.4.1.211.1.31.1.2.200.2.24 | displaystring | no-access |
|
trapSourceIp | 1.3.6.1.4.1.211.1.31.1.2.200.2.25 | displaystring | no-access |
|
trapDestIp | 1.3.6.1.4.1.211.1.31.1.2.200.2.26 | displaystring | no-access |
|
trapModelName | 1.3.6.1.4.1.211.1.31.1.2.200.2.27 | displaystring | no-access |
Model name of trap source. |
partitionEnterprise | 1.3.6.1.4.1.211.1.31.1.2.201 | |||
psaComTrap | 1.3.6.1.4.1.211.1.31.1.2.201.1 | |||
psaWinIntelE100Trap | 1.3.6.1.4.1.211.1.31.1.2.201.51 | |||
psaWinIntelE1000Trap | 1.3.6.1.4.1.211.1.31.1.2.201.52 | |||
psaWinBcm5700Trap | 1.3.6.1.4.1.211.1.31.1.2.201.53 | |||
psaWinEmulexTrap | 1.3.6.1.4.1.211.1.31.1.2.201.54 | |||
psaWinLsiLogicTrap | 1.3.6.1.4.1.211.1.31.1.2.201.55 | |||
psaWinDiskTrap | 1.3.6.1.4.1.211.1.31.1.2.201.56 | |||
psaWinGrmpdTrap | 1.3.6.1.4.1.211.1.31.1.2.201.57 | |||
psaWinDiskMirrorTrap | 1.3.6.1.4.1.211.1.31.1.2.201.58 | |||
psaWinXframe2Trap | 1.3.6.1.4.1.211.1.31.1.2.201.59 | |||
psaWinIntelE1000expTrap | 1.3.6.1.4.1.211.1.31.1.2.201.60 | |||
psaWinSvsRaidTrap | 1.3.6.1.4.1.211.1.31.1.2.201.61 | |||
psaWinMpdTrap | 1.3.6.1.4.1.211.1.31.1.2.201.62 | |||
psaWinGlsTrap | 1.3.6.1.4.1.211.1.31.1.2.201.63 | |||
psaWinIntele1expressTrap | 1.3.6.1.4.1.211.1.31.1.2.201.64 | |||
psaWinIntelixgbnTrap | 1.3.6.1.4.1.211.1.31.1.2.201.65 | |||
psaSVAgentsTrap | 1.3.6.1.4.1.211.1.31.1.2.201.102 | |||
svraidWinEvent0 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28500 |
SV RAID: Adapter error (BBU temperature out of range) |
||
svraidWinEvent1 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28501 |
SV RAID: Adapter error (BBU temperature unstable) |
||
svraidWinEvent2 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28502 |
SV RAID: Adapter error (BBU temperature above threshold) |
||
svraidWinEvent3 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28503 |
SV RAID: Adapter error (BBU voltage out of range) |
||
svraidWinEvent4 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28504 |
SV RAID: Adapter error (BBU voltage unstable) |
||
svraidWinEvent5 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28505 |
SV RAID: Adapter error (BBU communication error) |
||
svraidWinEvent6 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28506 |
SV RAID: Adapter error (BBU failed) |
||
svraidWinEvent7 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28507 |
SV RAID: Adapter error (BBU fast charging failed) |
||
svraidWinEvent8 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28508 |
SV RAID: Adapter error (BBU charge count exceeded) |
||
svraidWinEvent9 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28509 |
SV RAID: Device error (Rebuild on disk failed) |
||
svraidWinEvent10 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28510 |
SV RAID: Device error (Rebuild failed on logical drive) |
||
svraidWinEvent11 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28511 |
SV RAID: Device error (Migration failed on logical drive) |
||
svraidWinEvent12 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28512 |
SV RAID: Device error (Migration aborted on logical drive) |
||
svraidWinEvent13 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28513 |
SV RAID: Device error (Logical drive degraded) |
||
svraidWinEvent14 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28514 |
SV RAID: Device error (Logical drive failed) |
||
svraidWinEvent15 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28515 |
SV RAID: Adapter error (BBU voltage problem detected) |
||
svraidWinEvent16 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28516 |
SV RAID: Adapter error (BBU temperature problem detected) |
||
svraidWinEvent17 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28517 |
SV RAID: Adapter error (BBU failed) |
||
svraidWinEvent18 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28518 |
SV RAID: Adapter error (Fatal firmware error) |
||
svraidWinEvent19 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28519 |
SV RAID: Adapter error (Multi-bit ECC error) |
||
svraidWinEvent20 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28520 |
SV RAID: Adapter error (Single-bit ECC error) |
||
svraidWinEvent21 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28521 |
SV RAID: Adapter error (Not enough adapter memory) |
||
svraidWinEvent22 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28522 |
SV RAID: Device error (Resume migration of logical drive failed due to Configuration Mismatch) |
||
svraidWinEvent23 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28523 |
SV RAID: Device error (Hot spare S.M.A.R.T. polling failed on disk) |
||
svraidWinEvent24 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28524 |
SV RAID: Device error (Predictive failure) |
||
svraidWinEvent25 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28525 |
SV RAID: Adapter error (BBU needs to be replaced - SOH bad) |
||
svraidWinEvent26 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28526 |
SV RAID: Adapter error (BBU removed) |
||
svraidWinEvent27 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28527 |
SV RAID: Adapter error (Enclosure communication lost) |
||
svraidWinEvent28 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28528 |
SV RAID: Adapter error (Enclosure not responding) |
||
svraidWinEvent29 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28529 |
SV RAID: Adapter error (SAS/SATA mixing not supported in enclosure) |
||
svraidWinEvent30 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28530 |
SV RAID: Device error (Bad block table on disk is 80 percent full) |
||
svraidWinEvent31 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28531 |
SV RAID: Device error (Bad block table on disk is full; unable to log Block) |
||
svraidWinEvent32 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28532 |
SV RAID: Adapter error (BBU/charger problems detected; SOH bad) |
||
svraidWinEvent33 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28533 |
SV RAID: Adapter error (Single-bit ECC error; warning threshold exceeded) |
||
svraidWinEvent34 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28534 |
SV RAID: Adapter error (Single-bit ECC error; critical threshold exceeded) |
||
svraidWinEvent35 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28535 |
SV RAID: Adapter error (Single-bit ECC error; further reporting disabled) |
||
svraidWinEvent36 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28536 |
SV RAID: Adapter error (Previous configuration completely missing at boot) |
||
svraidWinEvent37 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28537 |
SV RAID: Device error (Logical drive partially degraded) |
||
svraidWinEvent38 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28538 |
SV RAID: Device error (Disks missing) |
||
svraidWinEvent39 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28539 |
SV RAID: Device error (State change on logical drive from operational to degraded) |
||
svraidWinEvent40 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28540 |
SV RAID: Device error (State change on logical drive from operational to partially degraded) |
||
svraidWinEvent41 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28541 |
SV RAID: Device error (State change on logical drive from operational to failed) |
||
svraidWinEvent42 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28542 |
SV RAID: Device error (State change on logical drive from degraded to degraded) |
||
svraidWinEvent43 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28543 |
SV RAID: Device error (State change on logical drive from degraded to partially degraded) |
||
svraidWinEvent44 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28544 |
SV RAID: Device error (State change on logical drive from degraded to failed) |
||
svraidWinEvent45 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28545 |
SV RAID: Device error (State change on logical drive from partially degraded to degraded) |
||
svraidWinEvent46 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28546 |
SV RAID: Device error (State change on logical drive from partially degraded to partially degraded) |
||
svraidWinEvent47 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28547 |
SV RAID: Device error (State change on logical drive from partially degraded to failed) |
||
svraidWinEvent48 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28548 |
SV RAID: Device error (State change on logical drive from failed to failed) |
||
svraidWinEvent49 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28549 |
SV RAID: Device error (State change by user on disk from failed to failed) |
||
svraidWinEvent50 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28550 |
SV RAID: Device error (State change by user on disk from hotspare to failed) |
||
svraidWinEvent51 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28551 |
SV RAID: Device error (State change by user on disk from rebuilding to failed) |
||
svraidWinEvent52 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28552 |
SV RAID: Device error (State change by user on disk from operational to failed) |
||
svraidWinEvent53 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28553 |
SV RAID: Device error (State change on disk from failed to failed) |
||
svraidWinEvent54 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28554 |
SV RAID: Device error (State change on disk from hot spare to failed) |
||
svraidWinEvent55 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28555 |
SV RAID:%s Device error (State change on disk from rebuilding to failed) |
||
svraidWinEvent56 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28556 |
SV RAID:%s Device error (State change on disk from operational to failed) |
||
svraidWinEvent57 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28557 |
SV RAID: Device error (Disk missing after reboot) |
||
svraidWinEvent58 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28558 |
SV RAID: Adapter error (Logical drive missing after reboot) |
||
svraidWinEvent59 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28559 |
SV RAID: Device error (State change by user on disk from hot spare to offline) |
||
svraidWinEvent60 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28560 |
SV RAID: Device error (State change by user on disk from offline to failed) |
||
svraidWinEvent61 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28561 |
SV RAID: Device error (State change by user on disk from operational to offline) |
||
svraidWinEvent62 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28562 |
SV RAID: Device error (State change by user on disk from rebuilding to offline) |
||
svraidWinEvent63 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28563 |
SV RAID: Device error (State change on disk from hot spare to offline) |
||
svraidWinEvent64 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28564 |
SV RAID: Device error (State change on disk from offline to failed) |
||
svraidWinEvent65 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28565 |
SV RAID: Device error (State change on disk from operational to offline) |
||
svraidWinEvent66 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28566 |
SV RAID: Device error (State change on disk from rebuilding to offline) |
||
svraidWinEvent67 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28567 |
SV RAID: Adapter error (SAS port lost link) |
||
svraidWinEvent68 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28568 |
SV RAID: Adapter error (Adapter missing after reboot) |
||
svraidWinEvent69 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28569 |
SV RAID: Adapter error (Adapter needs replacement; faulty IOP detected) |
||
svraidWinEvent70 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28570 |
SV RAID: Device error (Microcode update timeout on disk) |
||
svraidWinEvent71 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28571 |
SV RAID: Device error (Microcode update failed on disk) |
||
svraidWinEvent72 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28572 |
SV RAID: Device error (Adapter cache pinned for missing or offline logical drive) |
||
svraidWinEvent73 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28573 |
SV RAID: Device error (Adapter cache pinned for missing or offline logical drives) |
||
svraidWinEvent74 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28574 |
SV RAID: Device error (Adapter cache discarded by user for missing logical drives) |
||
svraidWinEvent75 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28575 |
SV RAID: Device error (Adapter cache destaged for logical drive) |
||
svraidWinEvent76 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28576 |
SV RAID: Adapter error (Internal hardware error) |
||
svraidWinEvent77 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28577 |
SV RAID: Adapter error (Internal hardware error during POST) |
||
svraidWinEvent78 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28578 |
SV RAID: Device error (Bad block table of disk threshold exceeded; table is about to overflow) |
||
svraidWinEvent79 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28579 |
SV RAID: Device error (Disk failed due to bad block table overflow) |
||
svraidWinEvent80 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28580 |
SV RAID: Device error (Disk failure detected during POST) |
||
svraidWinEvent81 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28581 |
SV RAID: Adapter error (Failure detected during POST) |
||
svraidWinEvent82 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28582 |
SV RAID: Device error (Multiple failure on disk detected) |
||
svraidWinEvent83 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28583 |
SV RAID: Device error (Disk failed since it never entered ready state) |
||
svraidWinEvent84 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28584 |
SV RAID: Adapter error (Internal software interface error) |
||
svraidWinEvent85 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28585 |
SV RAID: Adapter error (Device open error) |
||
svraidWinEvent86 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28586 |
SV RAID: Adapter error (Ioctl send error) |
||
svraidWinEvent87 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28587 |
SV RAID: Adapter error (Insufficient application memory) |
||
svraidWinEvent88 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28588 |
SV RAID: Adapter error (System API error) |
||
svraidWinEvent89 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28589 |
SV RAID: Adapter error (Firmware initialization failed) |
||
svraidWinEvent90 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28590 |
SV RAID: Adapter error (Firmware recovery failed) |
||
svraidWinEvent91 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28591 |
SV RAID: Adapter error (BBU requires reconditioning; please initiate recalibration) |
||
svraidWinEvent92 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28592 |
SV RAID: Software error (Task for object cannot be started. The scheduler has disabled the task) |
||
svraidWinEvent93 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28593 |
SV RAID: Adapter error (SAS topology error) |
||
svraidWinEvent94 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28594 |
SV RAID: Device error (State change on disk from copyback to failed) |
||
svraidWinEvent95 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28595 |
SV RAID: Device error (State change on disk from copyback to offline) |
||
svraidWinEvent96 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28596 |
SV RAID: Device error (State change on disk from JBOD to failed) |
||
svraidWinEvent97 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28597 |
SV RAID: Device error (State change on disk from JBOD to offline) |
||
svraidWinEvent98 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28598 |
SV RAID: Device error (State change by user on disk from copyback to failed) |
||
svraidWinEvent99 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28599 |
SV RAID: Device error (State change by user on disk from copyback to offline) |
||
svraidWinEvent100 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28600 |
SV RAID: Device error (State change by user on disk from JBOD to failed) |
||
svraidWinEvent101 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28601 |
SV RAID: Adapter error (Disk security failed to communicate with EKMS) |
||
svraidWinEvent102 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28602 |
SV RAID: Adapter error (Logical drive secure failed) |
||
svraidWinEvent103 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28603 |
SV RAID: Adapter error (Controller encountered a fatal error and was reset) |
||
svraidWinEvent104 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28604 |
SV RAID: Device error (Configuration command could not be committed to disk) |
||
svraidWinEvent105 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28605 |
SV RAID: Device error (Power state change failed on disk) |
||
svraidWinEvent106 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28606 |
SV RAID: Device error (Power state change failed on disk (from stopped to active)) |
||
svraidWinEvent107 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28607 |
SV RAID: Device error (Logical drive is not ready) |
||
svraidWinEvent108 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28608 |
SV RAID: Adapter error (Adapter has been replaced during reboot) |
||
svraidWinEvent109 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28609 |
SV RAID: Adapter error (Enclosure power supply removed) |
||
svraidWinEvent110 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28610 |
SV RAID: Adapter error (Enclosure power supply turned off) |
||
svraidWinEvent111 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28611 |
SV RAID: Adapter error (Enclosure temperature sensor below warning threshold) |
||
svraidWinEvent112 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28612 |
SV RAID: Adapter error (Enclosure temperature sensor below error threshold) |
||
svraidWinEvent113 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28613 |
SV RAID: Adapter error (Enclosure temperature sensor above warning threshold) |
||
svraidWinEvent114 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28614 |
SV RAID: Adapter error (Enclosure temperature sensor above error threshold) |
||
svraidWinEvent115 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28615 |
SV RAID: Device error (Power state change failed on disk (from active to transition)) |
||
svraidWinEvent116 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28616 |
SV RAID: Device error (Power state change failed on disk (from stopped to transition)) |
||
svraidWinEvent117 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28617 |
SV RAID: Device error (Power state change failed on disk (from transition to active)) |
||
svraidWinEvent118 | 1.3.6.1.4.1.211.1.31.1.2.201.610.28618 |
SV RAID: Device error (Power state change failed on disk (from transition to stopped)) |