PRVT-SYS-MON-MIB: View SNMP OID List / Download MIB

VENDOR: B.A.T.M. ADVANCE TECHNOLOGIES


 Home MIB: PRVT-SYS-MON-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 software 1.3.6.1.4.1.738.1.111
         prvtSysMonMib 1.3.6.1.4.1.738.1.111.3
Information for system resources
             prvtSysMonNotifications 1.3.6.1.4.1.738.1.111.3.0
                 cpuUtilizationExceeded 1.3.6.1.4.1.738.1.111.3.0.1
The cpuUtilizationExceeded notification indicates that the sending agent sense that the CPU utilization has passed the program threshold.
                 ramFreeSpaceExceeded 1.3.6.1.4.1.738.1.111.3.0.2
The ramFreeSpaceExceeded notification indicates that the sending agent sense that the system memory utilization has passed the program threshold.
                 portErrorsExceeded 1.3.6.1.4.1.738.1.111.3.0.3
The portErrorsExceeded notification indicates that the sending agent sense that the level of errors on the port has passed the program threshold.
                 portsBroadcastExceeded 1.3.6.1.4.1.738.1.111.3.0.4
The portsBroadcastExceeded notification indicates that the sending agent sense that the level of broadcast-limit has passed the program threshold.
                 portsCRCErrExceeded 1.3.6.1.4.1.738.1.111.3.0.5
The portsCRCErrExceeded notification indicates that the sending agent sense that the level of CRC error has passed the program threshold.
                 portsRuntsExceeded 1.3.6.1.4.1.738.1.111.3.0.6
The portsRuntsExceeded notification indicates that the sending agent sense that the level of runts has passed the program threshold.
                 portsOverSizeExceeded 1.3.6.1.4.1.738.1.111.3.0.7
The portsOverSizeExceeded notification indicates that the sending agent sense that the level of oversize has passed the program threshold.
                 laserTemperatureThresholdCrossed 1.3.6.1.4.1.738.1.111.3.0.8
The laserTemperatureThresholdCrossed shall be generated when laserTemperature rises above laserHighTemperatureThreshold or falls below laserTemperatureLowThreshold. Also the notification shall be generated when laserTemperature returns to the normal range between laserHighTemperatureThreshold and laserTemperatureLowThreshold.
                 laserTxPowerThresholdCrossed 1.3.6.1.4.1.738.1.111.3.0.9
The laserTxPowerThresholdCrossed shall be generated when laserTxPower rises above laserHighTxPowerThreshold or falls below laserTxPowerLowThreshold. Also the notification shall be generated when laserTxPower returns to the normal range between laserHighTxPowerThreshold and laserTxPowerLowThreshold.
                 laserRxPowerThresholdCrossed 1.3.6.1.4.1.738.1.111.3.0.10
The laserRxPowerThresholdCrossed shall be generated when laserRxPower rises above laserHighRxPowerThreshold or falls below laserRxPowerLowThreshold. Also the notification shall be generated when laserRxPower returns to the normal range between laserHighRxPowerThreshold and laserRxPowerLowThreshold.
                 sfpMonStatusChanged 1.3.6.1.4.1.738.1.111.3.0.11
This trap will be send only if the SFP is inserted or extracted
             prvtSysMonObjects 1.3.6.1.4.1.738.1.111.3.1
                 sysMonThreshold 1.3.6.1.4.1.738.1.111.3.1.1
                     cpuUtilizationThreshold 1.3.6.1.4.1.738.1.111.3.1.1.1 integer32 read-only
High limit in percent of normal CPU utilization
                     ramBytesFreeThreshold 1.3.6.1.4.1.738.1.111.3.1.1.2 integer32 read-only
Low limit in bytes free in the system memory
                     portErrorsThreshold 1.3.6.1.4.1.738.1.111.3.1.1.3 integer32 read-only
High limit in percent of communication errors on port
                     portsBroadcastThreshold 1.3.6.1.4.1.738.1.111.3.1.1.4 integer32 read-only
High limit in percent of exceeding broadcast-limit on port
                     portsCRCErrThreshold 1.3.6.1.4.1.738.1.111.3.1.1.5 integer32 read-only
High limit in percent of exceeding CRC error on port
                     portsRuntsThreshold 1.3.6.1.4.1.738.1.111.3.1.1.6 integer32 read-only
High limit in percent of exceeding runts on port
                     portsOverSizeThreshold 1.3.6.1.4.1.738.1.111.3.1.1.7 integer32 read-only
High limit in percent of exceeding over-size on port
                     laserPortThresholdTable 1.3.6.1.4.1.738.1.111.3.1.1.8 no-access
Defines thresholds for each port in the device
                         laserPortThresholdEntry 1.3.6.1.4.1.738.1.111.3.1.1.8.1 no-access
                             laserTemperatureHighThreshold 1.3.6.1.4.1.738.1.111.3.1.1.8.1.1 integer32 read-write
Configures high temperature threshold. The range is -128 to 128. The accuracy is 1C.
                             laserTemperatureLowThreshold 1.3.6.1.4.1.738.1.111.3.1.1.8.1.2 integer32 read-write
Configures low temperature threshold. The range is -128 to 128. The accuracy is 1C.
                             laserTxPowerHighThreshold 1.3.6.1.4.1.738.1.111.3.1.1.8.1.3 integer32 read-write
Configures Tx power high threshold. The range is -40 to 8.
                             laserTxPowerLowThreshold 1.3.6.1.4.1.738.1.111.3.1.1.8.1.4 integer32 read-write
Configures Tx power low threshold. The range is -40 to 8.
                             laserRxPowerHighThreshold 1.3.6.1.4.1.738.1.111.3.1.1.8.1.5 integer32 read-write
Configures Rx power high threshold. The range is -40 to 8.
                             laserRxPowerLowThreshold 1.3.6.1.4.1.738.1.111.3.1.1.8.1.6 integer32 read-write
Configures Rx power low threshold. The range is -40 to 8.
                 sysMonValues 1.3.6.1.4.1.738.1.111.3.1.2
                     monCpuUtilization 1.3.6.1.4.1.738.1.111.3.1.2.1 integer32 read-only
The current level in percent of CPU utilization
                     monRamBytesFree 1.3.6.1.4.1.738.1.111.3.1.2.2 integer32 no-access
The number of bytes currently free in the system memory
                     monPortsTable 1.3.6.1.4.1.738.1.111.3.1.2.3 no-access
Defines the ports monitor Table for providing, via SNMP, the last sampled parameters by the periodic monitor
                         monPortsEntry 1.3.6.1.4.1.738.1.111.3.1.2.3.1 no-access
Defines an entry in the monPortsTable. The entries are indexed by the physical location of the port in the device.
                             monPortErrors 1.3.6.1.4.1.738.1.111.3.1.2.3.1.1 integer32 no-access
The percentages of errors on the port that generated the notification.
                             monPortBroadcast 1.3.6.1.4.1.738.1.111.3.1.2.3.1.2 integer32 no-access
The percentages of packets exceeding broadcast-limit on the port that generated the notification.
                             monPortCRCErr 1.3.6.1.4.1.738.1.111.3.1.2.3.1.3 integer32 no-access
The percentage of CRC errors on the port that generated the notification.
                             monPortRunts 1.3.6.1.4.1.738.1.111.3.1.2.3.1.4 integer32 no-access
The percentage of runt packets on the port that generated the notification.
                             monPortOverSize 1.3.6.1.4.1.738.1.111.3.1.2.3.1.5 integer32 no-access
The percentage of over-size packets on the port that generated the notification.
                     laserPortValueTable 1.3.6.1.4.1.738.1.111.3.1.2.4 no-access
This table displays the current laser-related values for each port in the device.
                         laserPortValueEntry 1.3.6.1.4.1.738.1.111.3.1.2.4.1 no-access
                             sfpStatus 1.3.6.1.4.1.738.1.111.3.1.2.4.1.1 integer read-only
If value of this field is not supported, then the values of other fields are not relevant. The value is supported only if SFP compliant with SFF-8472 is inserted. Enumeration: 'lm-supported': 1, 'lm-not-supported': 2, 'extracted': 3.
                             laserTemperature 1.3.6.1.4.1.738.1.111.3.1.2.4.1.2 integer32 read-only
Represents module temperature. The range is -128 to 128. The accuracy is 1C.
                             laserTxPower 1.3.6.1.4.1.738.1.111.3.1.2.4.1.3 integer32 read-only
Represents Tx power. The range is -40 to 8.
                             laserRxPower 1.3.6.1.4.1.738.1.111.3.1.2.4.1.4 integer32 read-only
Represents Rx power. The range is -40 to 8.
                     sfpPortManTable 1.3.6.1.4.1.738.1.111.3.1.2.5 no-access
This table will be responsible for managing SFPs.
                         sfpPortManEntry 1.3.6.1.4.1.738.1.111.3.1.2.5.1 no-access
                             sfpMonStatus 1.3.6.1.4.1.738.1.111.3.1.2.5.1.1 integer read-only
This object gives information is SFP is inserted or not in the port. Enumeration: 'sfpExtracted': 2, 'sfpInserted': 1, 'sfpUnknown': 3.
                             sfpVendor 1.3.6.1.4.1.738.1.111.3.1.2.5.1.2 displaystring read-only
This object gives SFP vendor name.
                             sfpPN 1.3.6.1.4.1.738.1.111.3.1.2.5.1.3 displaystring read-only
This object gives SFP vendor name.
                             sfpRevision 1.3.6.1.4.1.738.1.111.3.1.2.5.1.4 displaystring read-only
This object gives SFP vendor revision.
                             sfpLenght 1.3.6.1.4.1.738.1.111.3.1.2.5.1.5 displaystring read-only
This object gives information regarding link length.
                             sfpConnector 1.3.6.1.4.1.738.1.111.3.1.2.5.1.6 displaystring read-only
This object gives SFP connector type.
                 sysMonConfig 1.3.6.1.4.1.738.1.111.3.1.3
                     sysMonConfigTable 1.3.6.1.4.1.738.1.111.3.1.3.1 no-access
This table configures periodic monitoring parameters.
                         sysMonConfigEntry 1.3.6.1.4.1.738.1.111.3.1.3.1.1 no-access
                             sysMonIndicator 1.3.6.1.4.1.738.1.111.3.1.3.1.1.1 integer read-only
Enumeration. Enumeration: 'laser': 7, 'temperature': 6, 'onboard-power': 4, 'power-supply': 3, 'cpu-usage': 1, 'ram-usage': 2, 'fan': 5.
                             sysMonEnable 1.3.6.1.4.1.738.1.111.3.1.3.1.1.2 enablestatus read-write
Enabled/disabled
                             sysMonPeriod 1.3.6.1.4.1.738.1.111.3.1.3.1.1.3 integer32 read-write
Configure monitoring period in seconds.
                             sysMonTrap 1.3.6.1.4.1.738.1.111.3.1.3.1.1.4 enablestatus read-write
Enabled/disabled
                             sysMonLog 1.3.6.1.4.1.738.1.111.3.1.3.1.1.5 enablestatus read-write
Enabled/disabled
                             sysMonLed 1.3.6.1.4.1.738.1.111.3.1.3.1.1.6 enablestatus read-write
Enabled/disabled
                             sysMonDefaults 1.3.6.1.4.1.738.1.111.3.1.3.1.1.7 integer read-write
If set to 1, resets all configurations to defaults. Enumeration: 'reset': 1, 'noop': 0.
             prvtSysMonConformance 1.3.6.1.4.1.738.1.111.3.2
                 sysMonMIBGroups 1.3.6.1.4.1.738.1.111.3.2.2
                     sysMonNotificationGroup 1.3.6.1.4.1.738.1.111.3.2.2.3
Private Notification Group.