PRVT-SYNC-ETHERNET-MIB: View SNMP OID List / Download MIB
VENDOR: B.A.T.M. ADVANCE TECHNOLOGIES
Home | MIB: PRVT-SYNC-ETHERNET-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
prvtSyncEthernetMIB | 1.3.6.1.4.1.738.1.5.170 |
This is the MIB module to manage synchronization over ethernet. |
||
prvtSyncEthernetMIBNotifications | 1.3.6.1.4.1.738.1.5.170.0 | |||
syncEthernetInvalidESMC | 1.3.6.1.4.1.738.1.5.170.0.1 |
Invalid ESMC has been received. |
||
syncEthernetQualityLevelChange | 1.3.6.1.4.1.738.1.5.170.0.2 |
Current value of syncEthernetClockSourceQuality has been changed. |
||
syncEthernetInvalidQualityLevelReceived | 1.3.6.1.4.1.738.1.5.170.0.3 |
Invalid Quality level equals to QL-INVx has been received. |
||
syncEthernetDPLLReferenceChange | 1.3.6.1.4.1.738.1.5.170.0.4 |
DPLL's reference clock changed. |
||
syncEthernetDPLLChanged | 1.3.6.1.4.1.738.1.5.170.0.5 |
Some of the DPLL's operational status changes. |
||
syncEthernetDPLLLockFailed | 1.3.6.1.4.1.738.1.5.170.0.6 |
If after new Reference selection the DPLL can't lock onto it, this will affect the Clock Source associated with that reference |
||
prvtSyncEthernetMIBObjects | 1.3.6.1.4.1.738.1.5.170.1 | |||
syncEthernetHoldOffTime | 1.3.6.1.4.1.738.1.5.170.1.1 | integer32 | read-write |
Timeout value, in millisseconds, for the hold-off timer. |
syncEthernetWaitToRestoreTime | 1.3.6.1.4.1.738.1.5.170.1.2 | integer32 | read-write |
Timeout value, in minutes, for the wait-to-restore timer. |
syncEthernetG781OptionMode | 1.3.6.1.4.1.738.1.5.170.1.3 | integer | read-write |
Specify which G.781 option mode to operate in. Enumeration: 'option2': 2, 'option1': 1. |
syncEthernetClockSourceTable | 1.3.6.1.4.1.738.1.5.170.1.10 | no-access |
Source clock synchronization table. |
|
1.3.6.1.4.1.738.1.5.170.1.10.1 | no-access |
Source clock synchronization entry. |
||
syncEthernetClockSourceRowStatus | 1.3.6.1.4.1.738.1.5.170.1.10.1.2 | rowstatus | read-only |
Clock source synchronization table rowstatus. |
syncEthernetClockSourceAdminStatus | 1.3.6.1.4.1.738.1.5.170.1.10.1.3 | integer | read-only |
Enable clock source. Enumeration: 'down': 2, 'up': 1. |
syncEthernetClockSourceEsmc | 1.3.6.1.4.1.738.1.5.170.1.10.1.4 | truthvalue | read-only |
Enable receiving ESMC messages (Synchronization Status Messages). Only applicable for BITS clock sources. |
syncEthernetClockSourceFrequency | 1.3.6.1.4.1.738.1.5.170.1.10.1.5 | unsigned32 | read-only |
Specify input frequency - N*8kHz Only applicable for BITS clock sources. |
syncEthernetClockSourceQuality | 1.3.6.1.4.1.738.1.5.170.1.10.1.6 | prvtsyncethernetqualityleveltype | read-only |
Specify quality level In G781-option I mode, valid values are prs, ssuA, ssuB, dnu. In G781-option II mode, valid values are stu, prs, tnc, st2, st3, smc, st3e, dus, prov. |
syncEthernetClockSourceQualityChangeNotify | 1.3.6.1.4.1.738.1.5.170.1.10.1.7 | truthvalue | read-only |
Enable quality level change notifications |
syncEthernetClockSourceRecvQualityLevel | 1.3.6.1.4.1.738.1.5.170.1.10.1.8 | prvtsyncethernetqualityleveltype | read-only |
The received quality level value. |
syncEthernetClockSourceLastRecvEsmcPduTime | 1.3.6.1.4.1.738.1.5.170.1.10.1.9 | dateandtime | read-only |
Time elapsed since the last valid ESMC message received |
syncEthernetClockSourceLastRecvEsmcErrorPduTime | 1.3.6.1.4.1.738.1.5.170.1.10.1.10 | dateandtime | read-only |
Time elapsed since the last invalid ESMC message received |
syncEthernetClockSourceLastRecvEsmcPduType | 1.3.6.1.4.1.738.1.5.170.1.10.1.11 | unsigned32 | read-only |
Last received ESMC message type |
syncEthernetClockSourceLastRecvLastError | 1.3.6.1.4.1.738.1.5.170.1.10.1.12 | unsigned32 | read-only |
Last error code |
syncEthernetClockSourceNumRecvEsmcPdu | 1.3.6.1.4.1.738.1.5.170.1.10.1.13 | unsigned32 | read-only |
Total number of received ESMC messages |
syncEthernetClockSourceNumDiscEsmcPdu | 1.3.6.1.4.1.738.1.5.170.1.10.1.14 | unsigned32 | read-only |
Total number of discarded ESMC messages |
syncEthernetClockSourceNumSignalFail | 1.3.6.1.4.1.738.1.5.170.1.10.1.15 | unsigned32 | read-only |
Total number of generated signal failure events |
syncEthernetClockSourceQualityInvalidNotify | 1.3.6.1.4.1.738.1.5.170.1.10.1.16 | truthvalue | read-only |
Enable invalid quality notifications |
syncEthernetClockSourceEsmcInvalidNotify | 1.3.6.1.4.1.738.1.5.170.1.10.1.17 | truthvalue | read-only |
Enable invalid ESMC notifications |
syncEthernetClockOutputTable | 1.3.6.1.4.1.738.1.5.170.1.12 | no-access |
Output clock synchronization table. |
|
1.3.6.1.4.1.738.1.5.170.1.12.1 | no-access |
Output clock synchronization entry. |
||
syncEthernetClockOutputRowStatus | 1.3.6.1.4.1.738.1.5.170.1.12.1.2 | rowstatus | read-only |
syncEthernetClockOutput table rowStatus |
syncEthernetClockOutputEsmc | 1.3.6.1.4.1.738.1.5.170.1.12.1.3 | truthvalue | read-only |
Enable sending ESMC messages Only applicable for BITS clock outputs. |
syncEthernetClockOutputFrequency | 1.3.6.1.4.1.738.1.5.170.1.12.1.4 | unsigned32 | read-only |
Specify output frequency - N*8kHz Only applicable for BITS clock outputs. |
syncEthernetClockOutputDpll | 1.3.6.1.4.1.738.1.5.170.1.12.1.5 | integer32 | read-only |
Assign output clock to DPLL Only applicable for BITS clock outputs. Must be set to the syncEthernetDpllModuleId value of an existing row in syncEthernetDpllTable. |
syncEthernetClockOutputQualityLevel | 1.3.6.1.4.1.738.1.5.170.1.12.1.6 | prvtsyncethernetqualityleveltype | read-only |
Last quality level value sent |
syncEthernetClockOutputLastQualityLevelChange | 1.3.6.1.4.1.738.1.5.170.1.12.1.7 | dateandtime | read-only |
Time elapsed since the last quality level change |
syncEthernetClockOutputMsgEvent | 1.3.6.1.4.1.738.1.5.170.1.12.1.8 | truthvalue | read-only |
Last ESMC message type sent |
syncEthernetClockOutputNumTransmittedEsmcPdu | 1.3.6.1.4.1.738.1.5.170.1.12.1.9 | unsigned32 | read-only |
Total number of ESMC messages sent |
syncEthernetClockOutputNumTransmittedEventEsmcPdu | 1.3.6.1.4.1.738.1.5.170.1.12.1.10 | unsigned32 | read-only |
Total number of ESMC messages sent |
syncEthernetDpllTable | 1.3.6.1.4.1.738.1.5.170.1.14 | no-access |
Synchronization DPLL table |
|
1.3.6.1.4.1.738.1.5.170.1.14.1 | no-access |
Synchronization DPLL entry |
||
syncEthernetDpllModuleId | 1.3.6.1.4.1.738.1.5.170.1.14.1.1 | integer32 | no-access |
Synchronization DPLL module index |
syncEthernetDpllRowStatus | 1.3.6.1.4.1.738.1.5.170.1.14.1.2 | rowstatus | read-only |
Synchronization DPLL rowstatus |
syncEthernetDpllAdminStatus | 1.3.6.1.4.1.738.1.5.170.1.14.1.3 | integer | read-only |
Administrative status of the DPLL Enumeration: 'down': 2, 'up': 1. |
syncEthernetDpllReferenceSelection | 1.3.6.1.4.1.738.1.5.170.1.14.1.4 | integer | read-only |
Specify reference selection mode Enumeration: 'freerun': 1, 'static': 2, 'g781': 3. |
syncEthernetDpllEnableQualityLevel | 1.3.6.1.4.1.738.1.5.170.1.14.1.5 | truthvalue | read-only |
Enable reference selection based on quality level Only applicable when syncEthernetDpllReferenceSelection equals g781. |
syncEthernetDpllStatusChangeNotify | 1.3.6.1.4.1.738.1.5.170.1.14.1.6 | truthvalue | read-only |
Enable DPLL status change notifications |
syncEthernetDpllReferenceChangeNotify | 1.3.6.1.4.1.738.1.5.170.1.14.1.7 | truthvalue | read-only |
Enable reference clock change notifications |
syncEthernetDpllStatus | 1.3.6.1.4.1.738.1.5.170.1.14.1.8 | integer | read-only |
DPLL operational status Enumeration: 'refFailure': 3, 'freerun': 0, 'locked': 1, 'holdover': 2. |
syncEthernetDpllStatusLastChange | 1.3.6.1.4.1.738.1.5.170.1.14.1.9 | dateandtime | read-only |
Time since last DPLL status change |
syncEthernetDpllSystemQualityLevel | 1.3.6.1.4.1.738.1.5.170.1.14.1.10 | prvtsyncethernetqualityleveltype | read-only |
System quality level |
syncEthernetDpllSystemQualityLevelLastChange | 1.3.6.1.4.1.738.1.5.170.1.14.1.11 | dateandtime | read-only |
Time since last system quality level change |
syncEthernetDpllSelectedReferenceClock | 1.3.6.1.4.1.738.1.5.170.1.14.1.12 | octet string | read-only |
The selected reference clock source |
syncEthernetDpllSelectedReferenceClockChange | 1.3.6.1.4.1.738.1.5.170.1.14.1.13 | dateandtime | read-only |
Time since last reference clock change |
syncEthernetDpllClkRefTable | 1.3.6.1.4.1.738.1.5.170.1.16 | no-access |
Synchronization DPLL clock reference table |
|
1.3.6.1.4.1.738.1.5.170.1.16.1 | no-access |
Synchronization DPLL clock reference entry |
||
syncEthernetDpllClkRefRowStatus | 1.3.6.1.4.1.738.1.5.170.1.16.1.2 | rowstatus | read-only |
Synchronization DPLL clock reference rowstatus |
syncEthernetDpllClkRefPriority | 1.3.6.1.4.1.738.1.5.170.1.16.1.3 | unsigned32 | read-only |
Specify reference clock priority |
syncEthernetDpllClkRefLockOut | 1.3.6.1.4.1.738.1.5.170.1.16.1.4 | truthvalue | read-only |
Lock reference clock |
syncEthernetDpllClkRefFailStatus | 1.3.6.1.4.1.738.1.5.170.1.16.1.5 | integer32 | read-only |
DPLL reference clock status |