PRVT-LMM-MIB: View SNMP OID List / Download MIB

VENDOR: B.A.T.M. ADVANCE TECHNOLOGIES


 Home MIB: PRVT-LMM-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 prvtLmmMIB 1.3.6.1.4.1.738.1.5.172
Initial version. This MIB will configure laser monitoring
         prvtLmmNotifications 1.3.6.1.4.1.738.1.5.172.0
             prvtLmmTemperatureThresholdCrossed 1.3.6.1.4.1.738.1.5.172.0.1
The prvtLmmTemperatureThresholdCrossed shall be generated when prvtLmmInterfaceTempValue rises above prvtLmmInterfaceTempThresholdHi or falls below prvtLmmInterfaceTempThresholdLo. Also the notification shall be generated when prvtLmmInterfaceTempValue returns to the normal range between prvtLmmInterfaceTempThresholdHi and prvtLmmInterfaceTempThresholdLo.
             prvtLmmTxPowerThresholdCrossed 1.3.6.1.4.1.738.1.5.172.0.2
The prvtLmmTxPowerThresholdCrossed shall be generated when prvtLmmInterfaceTxPowerValue rises above prvtLmmInterfaceTxPowerThresholdTxHi or falls below prvtLmmInterfaceTxPowerThresholdTxLo. Also the notification shall be generated when prvtLmmInterfaceTxPowerValue returns to the normal range between prvtLmmInterfaceTxPowerThresholdTxHi and prvtLmmInterfaceTxPowerThresholdTxLo.
             prvtLmmRxPowerThresholdCrossed 1.3.6.1.4.1.738.1.5.172.0.3
The prvtLmmRxPowerThresholdCrossed shall be generated when prvtLmmInterfaceRxPowerValue rises above prvtLmmInterfaceRxPowerThresholdRxHi or falls below prvtLmmInterfaceRxPowerThresholdRxLo. Also the notification shall be generated when prvtLmmInterfaceRxPowerValue returns to the normal range between prvtLmmInterfaceRxPowerThresholdRxHi and prvtLmmInterfaceRxPowerThresholdRxLo.
         prvtLmmObjects 1.3.6.1.4.1.738.1.5.172.1
             prvtLmmShutdown 1.3.6.1.4.1.738.1.5.172.1.1 truthvalue read-write
Enable/disable laser monitoring
             prvtLmmDebug 1.3.6.1.4.1.738.1.5.172.1.2 truthvalue read-write
Enable/Disable laser monitoring
             prvtLmmPeriod 1.3.6.1.4.1.738.1.5.172.1.3 integer32 read-write
Specify the monitoring interval (sec).
             prvtLmmTrap 1.3.6.1.4.1.738.1.5.172.1.4 truthvalue read-write
Enable/Disable sending SNMP traps when thresholds are crossed
             prvtLmmLog 1.3.6.1.4.1.738.1.5.172.1.5 truthvalue read-write
Enable/Disable alert notification logging when thresholds are crossed
             prvtLmmLed 1.3.6.1.4.1.738.1.5.172.1.6 truthvalue read-write
Enable/Disable LED-alert notifications when thresholds are crossed
             prvtLmmTemperatureHighThreshold 1.3.6.1.4.1.738.1.5.172.1.7 integer32 read-write
Specify the low threshold value for global temperature (-128 up to 128). prvtLmmTemperatureHighThreshold must be higher than prvtLmmTemperatureLowThreshold
             prvtLmmTemperatureLowThreshold 1.3.6.1.4.1.738.1.5.172.1.8 integer32 read-write
Specify the low threshold value for global temperature (-128 up to 128). prvtLmmTemperatureHighThreshold must be higher than prvtLmmTemperatureLowThreshold
             prvtLmmRxPowerLowThreshold 1.3.6.1.4.1.738.1.5.172.1.9 integer32 read-write
Specify the low threshold value for global RX-power (-40 up to 8) prvtLmmRxPowerHighThreshold must be higher than prvtLmmRxPowerLowThreshold
             prvtLmmRxPowerHighThreshold 1.3.6.1.4.1.738.1.5.172.1.10 integer32 read-write
Specify the high threshold value for global RX-power (-40 up to 8) prvtLmmRxPowerHighThreshold must be higher than prvtLmmRxPowerLowThreshold
             prvtLmmTxPowerLowThreshold 1.3.6.1.4.1.738.1.5.172.1.11 integer32 read-write
Specify the low threshold value for global RX-power (-40 up to 8) prvtLmmTxPowerHighThreshold must be higher than prvtLmmTxPowerLowThreshold
             prvtLmmTxPowerHighThreshold 1.3.6.1.4.1.738.1.5.172.1.12 integer32 read-write
Specify the high threshold value for global RX-power (-40 up to 8) prvtLmmTxPowerHighThreshold must be higher than prvtLmmTxPowerLowThreshold
             prvtLmmInterfaceTable 1.3.6.1.4.1.738.1.5.172.1.13 no-access
Lmm configuration per ethernet port
                   prvtLmmInterfaceEntry 1.3.6.1.4.1.738.1.5.172.1.13.1 no-access
The Stack table entry
                       prvtLmmInterfaceShutdown 1.3.6.1.4.1.738.1.5.172.1.13.1.1 truthvalue read-write
Enable/Disable laser monitoring on port
                       prvtLmmInterfaceTempLowThreshold 1.3.6.1.4.1.738.1.5.172.1.13.1.2 integer32 read-write
Specify the low threshold value for port temperature
                       prvtLmmInterfaceTempHighThreshold 1.3.6.1.4.1.738.1.5.172.1.13.1.3 integer32 read-write
Specify the high threshold value for port temperature. Value of prvtLmmInterfaceTempHighThreshold must be greater than prvtLmmInterfaceTempLowThreshold
                       prvtLmmInterfaceTempValue 1.3.6.1.4.1.738.1.5.172.1.13.1.4 integer32 read-only
Display laser Temperature current value
                       prvtLmmInterfaceTempThresholdLo 1.3.6.1.4.1.738.1.5.172.1.13.1.5 integer32 read-only
The thresholds read from hardware or set by user
                       prvtLmmInterfaceTempThresholdHi 1.3.6.1.4.1.738.1.5.172.1.13.1.6 integer32 read-only
The thresholds read from hardware or set by user
                       prvtLmmInterfaceTempTestState 1.3.6.1.4.1.738.1.5.172.1.13.1.7 truthvalue read-only
The state test
                       prvtLmmInterfaceRxPowerLowThreshold 1.3.6.1.4.1.738.1.5.172.1.13.1.8 integer32 read-write
Specify the low threshold value for port RX-power.
                       prvtLmmInterfaceRxPowerHighThreshold 1.3.6.1.4.1.738.1.5.172.1.13.1.9 integer32 read-write
Specify the high threshold value for port RX-power. Value of prvtLmmInterfaceRxPowerHighThreshold must be greater than prvtLmmInterfaceRxPowerLowThreshold
                       prvtLmmInterfaceRxPowerValue 1.3.6.1.4.1.738.1.5.172.1.13.1.10 integer32 read-only
Display laser Rx Power current value
                       prvtLmmInterfaceRxPowerThresholdRxLo 1.3.6.1.4.1.738.1.5.172.1.13.1.11 integer32 read-only
The thresholds read from hardware or set by user
                       prvtLmmInterfaceRxPowerThresholdRxHi 1.3.6.1.4.1.738.1.5.172.1.13.1.12 integer32 read-only
The thresholds read from hardware or set by user
                       prvtLmmInterfaceRxPowerTestState 1.3.6.1.4.1.738.1.5.172.1.13.1.13 truthvalue read-only
The state test
                       prvtLmmInterfaceTxPowerLowThreshold 1.3.6.1.4.1.738.1.5.172.1.13.1.14 integer32 read-write
Specify the low threshold value for port TX-power
                       prvtLmmInterfaceTxPowerHighThreshold 1.3.6.1.4.1.738.1.5.172.1.13.1.15 integer32 read-write
Specify the high threshold value for port TX-power Value of prvtLmmInterfaceTxPowerHighThreshold must be greater than prvtLmmInterfaceTxPowerLowThreshold
                       prvtLmmInterfaceTxPowerValue 1.3.6.1.4.1.738.1.5.172.1.13.1.16 integer32 read-only
Display laser Tx Power current value
                       prvtLmmInterfaceTxPowerThresholdTxLo 1.3.6.1.4.1.738.1.5.172.1.13.1.17 integer32 read-only
The thresholds read from hardware or set by user
                       prvtLmmInterfaceTxPowerThresholdTxHi 1.3.6.1.4.1.738.1.5.172.1.13.1.18 integer32 read-only
The thresholds read from hardware or set by user
                       prvtLmmInterfaceTxPowerTestState 1.3.6.1.4.1.738.1.5.172.1.13.1.19 truthvalue read-only
The state test
                       prvtLmmInterfaceOperStatus 1.3.6.1.4.1.738.1.5.172.1.13.1.20 truthvalue read-only
Operational status