PRVT-ELMI-MIB: View SNMP OID List / Download MIB
VENDOR: B.A.T.M. ADVANCE TECHNOLOGIES
Home | MIB: PRVT-ELMI-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
prvtELMIMib | 1.3.6.1.4.1.738.1.5.120 |
This MIB contains managed object definitions for encapsulating E-LMI that is terminated by the UNI-C on the CE side of the UNI and by the UNI-N on the MEN side of the UNI. |
||
prvtELMINotifications | 1.3.6.1.4.1.738.1.5.120.0 | |||
prvtELMIStatus | 1.3.6.1.4.1.738.1.5.120.0.1 |
This notification is sent when status of ELMI changes. |
||
prvtELMIChangeEVC | 1.3.6.1.4.1.738.1.5.120.0.2 |
This notification is sent when status of CE-VLAN ID/EVC Map per interface changes. |
||
prvtELMIObjects | 1.3.6.1.4.1.738.1.5.120.1 | |||
prvtELMIEnable | 1.3.6.1.4.1.738.1.5.120.1.1 | integer | read-write |
E-LMI enable protocol Enumeration: 'enable': 1, 'disable': 2. |
prvtELMICfgTable | 1.3.6.1.4.1.738.1.5.120.1.2 | no-access |
This table contains object for configuring E-LMI protocol. |
|
1.3.6.1.4.1.738.1.5.120.1.2.1 | no-access | |||
prvtELMIIfEnable | 1.3.6.1.4.1.738.1.5.120.1.2.1.1 | integer | read-write |
Enables or disables E-LMI feature per interface. Enumeration: 'enable': 1, 'disable': 2. |
prvtELMIIfMode | 1.3.6.1.4.1.738.1.5.120.1.2.1.2 | integer | read-write |
E-LMI working mode per interface. Enumeration: 'uni-n': 1, 'uni-c': 2. |
prvtELMIPollingCnt | 1.3.6.1.4.1.738.1.5.120.1.2.1.3 | integer | read-write |
Polling counter - controls the number of polling cycles between Full Status exchanges. Aplicable only in UNI-C mode |
prvtELMIPollingTimer | 1.3.6.1.4.1.738.1.5.120.1.2.1.4 | integer | read-write |
Polling timer - controls the interval at which STATUS ENQUIRY messages are transmitted. Aplicable only in UNI-C mode |
prvtELMIVerifPollTimer | 1.3.6.1.4.1.738.1.5.120.1.2.1.5 | integer | read-write |
Polling Verification Timer - controls the interval during which information sent to the UNI-C in a STATUS message is consider valid. The Polling Verification Timer MAY be disabled and thus the PVT never expires. Polling Verification Timer is valid only for UNI-N mode. For disable the counter SET 0 value |
prvtELMIStatusCnt | 1.3.6.1.4.1.738.1.5.120.1.2.1.6 | integer | read-write |
Status Counter - controls the number of consecutive errors that must occur before E-LMI at the UNI is declared as not operational. Aplicable in both UNI-Cand UNI-N mode |
prvtELMIClearStatistics | 1.3.6.1.4.1.738.1.5.120.1.2.1.7 | integer | read-write |
Clear ELMI statistics per interface. Enumeration: 'none': 0, 'clear': 1. |
prvtELMIMapEvcCEVlanType | 1.3.6.1.4.1.738.1.5.120.1.2.1.8 | integer | read-only |
CE-VLAN ID/EVC Map Type . Enumeration: 'budling': 3, 'allToOneBundling': 1, 'serviceMultiplexingWithNoBund': 2. |
prvtELMIStatisticsTable | 1.3.6.1.4.1.738.1.5.120.1.3 | no-access |
This table contains objects for displaing E-LMI statistics. |
|
1.3.6.1.4.1.738.1.5.120.1.3.1 | no-access | |||
prvtELMIStatusChange | 1.3.6.1.4.1.738.1.5.120.1.3.1.1 | integer | read-only |
E-LMI operational status Enumeration: 'down': 2, 'up': 1. |
prvtELMILastFullReport | 1.3.6.1.4.1.738.1.5.120.1.3.1.2 | timestamp | read-only |
E-LMI Time of the last full status report. |
prvtELMITimeOuts | 1.3.6.1.4.1.738.1.5.120.1.3.1.3 | integer | read-only |
Number of Status Timeouts. |
prvtELMIMsgISN | 1.3.6.1.4.1.738.1.5.120.1.3.1.4 | integer | read-only |
Number of messages with Invalid Sequence Number. |
prvtELMIInavlidProtocolVers | 1.3.6.1.4.1.738.1.5.120.1.3.1.5 | integer | read-only |
Invalid Protocol Version. |
prvtELMIEVCInvalidRefId | 1.3.6.1.4.1.738.1.5.120.1.3.1.6 | integer | read-only |
Invalid Ethernet Virtual Connection Reference Id. |
prvtELMIInavlidMsgType | 1.3.6.1.4.1.738.1.5.120.1.3.1.7 | integer | read-only |
Invalid Message Type. |
prvtELMIOOSIE | 1.3.6.1.4.1.738.1.5.120.1.3.1.8 | integer | read-only |
Out of Sequence IE. |
prvtELMIDuplicateIE | 1.3.6.1.4.1.738.1.5.120.1.3.1.9 | integer | read-only |
Duplicate IE. |
prvtELMIMandatoryIEMissing | 1.3.6.1.4.1.738.1.5.120.1.3.1.10 | integer | read-only |
Mandatory IE Missing. |
prvtELMIInavlidMandatoryIE | 1.3.6.1.4.1.738.1.5.120.1.3.1.11 | integer | read-only |
Invalid Mandatory IE. |
prvtELMIInvalidNonMandatoryIE | 1.3.6.1.4.1.738.1.5.120.1.3.1.12 | integer | read-only |
Invalid non-Mandatory IE. |
prvtELMIUnrecognizedIE | 1.3.6.1.4.1.738.1.5.120.1.3.1.13 | integer | read-only |
Unrecognized IE. |
prvtELMIUnexpectedIE | 1.3.6.1.4.1.738.1.5.120.1.3.1.14 | integer | read-only |
Unexpected IE. |
prvtELMIShortMessage | 1.3.6.1.4.1.738.1.5.120.1.3.1.15 | integer | read-only |
Short Message. |
prvtELMIEVCTable | 1.3.6.1.4.1.738.1.5.120.1.4 | no-access |
This table contains objects for displaing EVC informations. |
|
1.3.6.1.4.1.738.1.5.120.1.4.1 | no-access |
An entry display information about EVC. |
||
prvtELMIEVCId | 1.3.6.1.4.1.738.1.5.120.1.4.1.1 | integer | no-access |
An integer that uniquely identifies EVC Refernces id. |
prvtELMIServicesId | 1.3.6.1.4.1.738.1.5.120.1.4.1.2 | unsigned32 | read-only |
An integer that uniquely identifies Services id. |
prvtELMIEVCStatus | 1.3.6.1.4.1.738.1.5.120.1.4.1.3 | integer | read-only |
EVC State. Enumeration: 'new-partially-active': 5, 'new-active': 3, 'new-non-active': 1, 'non-active': 0, 'partially-active': 4, 'active': 2. |
prvtELMIEVCType | 1.3.6.1.4.1.738.1.5.120.1.4.1.4 | integer | read-only |
EVC Type. Enumeration: 'multi-point-to-point': 2, 'point-to-point': 1. |
prvtELMIMapEvcCEVlanTable | 1.3.6.1.4.1.738.1.5.120.1.5 | no-access |
This table contains objects for displaying the map between EVC and CE-VLAN |
|
1.3.6.1.4.1.738.1.5.120.1.5.1 | no-access |
An entry links EVC id with CE-VLAN id. |
||
prvtELMIMapEVCId | 1.3.6.1.4.1.738.1.5.120.1.5.1.1 | integer | read-only |
An integer that uniquely identifies EVC id. |
prvtELMIMapCeVlanId | 1.3.6.1.4.1.738.1.5.120.1.5.1.2 | integer | read-only |
An integer that uniquely identifies CE-VLAN id. |
prvtELMIConformance | 1.3.6.1.4.1.738.1.5.120.2 |