PRVT-DRY-CONTACTS-MIB: View SNMP OID List / Download MIB
VENDOR: B.A.T.M. ADVANCE TECHNOLOGIES
Home | MIB: PRVT-DRY-CONTACTS-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
prvtDryContactsMIB | 1.3.6.1.4.1.738.1.5.112 |
Initial version. This MIB provides external-alarm management and notifications |
||
dryContactsNotifications | 1.3.6.1.4.1.738.1.5.112.0 | |||
stateChanged | 1.3.6.1.4.1.738.1.5.112.0.1 |
Send notification when operational status of the input changes |
||
dryContactsObjects | 1.3.6.1.4.1.738.1.5.112.1 | |||
cfgTable | 1.3.6.1.4.1.738.1.5.112.1.1 | no-access |
A table containing inputs configuration and statuses |
|
1.3.6.1.4.1.738.1.5.112.1.1.1 | no-access |
cfgEntry |
||
prvtAlarmID | 1.3.6.1.4.1.738.1.5.112.1.1.1.1 | integer32 | no-access |
External and internal alarm index uniquely identifies this row. T-Metro 200 ES platform has four dry-contacts sensor inputs. T5C-XG platform has four dry-contact sensor inputs and two dry-contact sensor outputs. An integer with supported range of values 1-6 for T5C-XG and 1-4 for T-Metro 200 ES. Index. Not-accessible |
prvtSensorType | 1.3.6.1.4.1.738.1.5.112.1.1.1.2 | integer | read-only |
Sensor type. An enumeration with two values: input(1), output(2). T-Metro 200 ES platform has four dry-contacts sensor inputs. T5C-XG platform has four dry-contact sensor inputs and two dry-contact sensor outputs. Read-only. Enumeration: 'input': 1, 'output': 2. |
prvtName | 1.3.6.1.4.1.738.1.5.112.1.1.1.3 | octet string | read-write |
Name of alarm. An OCTET-STRING with max. 16 OCTETS. Default value null string. Read-write |
prvtDescription | 1.3.6.1.4.1.738.1.5.112.1.1.1.4 | octet string | read-write |
Alarm description. An OCTET-STRING with max. 64 OCTETS. Default value null string. Read-write |
prvtEnableStatus | 1.3.6.1.4.1.738.1.5.112.1.1.1.5 | integer | read-write |
Senging alarms status. An enumeration with two values: enabled(1), disabled(2). Default value is disabled(2). Read-write Enumeration: 'disabled': 2, 'enabled': 1. |
prvtAlarmStatus | 1.3.6.1.4.1.738.1.5.112.1.1.1.6 | integer | read-only |
Alarm status. An enumeration with two values: no-alarm(1), alarm(2). Default value is no-alarm(1). Read-only. Enumeration: 'no-alarm': 1, 'alarm': 2. |
prvtAlarmSeverity | 1.3.6.1.4.1.738.1.5.112.1.1.1.7 | integer | read-write |
Configured alarm severity. An enumeration with 4 values: info(1), minor(2), major(3) and critical(4). Default value is info(1). Read-write Enumeration: 'info': 1, 'major': 3, 'critical': 4, 'minor': 2. |
prvtPolarity | 1.3.6.1.4.1.738.1.5.112.1.1.1.8 | integer | read-write |
Configured polarity. An enumeration with 2 values: normally-opened(1), normally-closed(2). This object is only for T-Metro 200 ES platform. Default value is normally-opened(1). Read-write Enumeration: 'normally-closed': 2, 'normally-opened': 1. |
prvtLastChange | 1.3.6.1.4.1.738.1.5.112.1.1.1.9 | timeticks | read-only |
The value of sysUpTime at the time of the last operational status change. TimeTicks. Read-only |