PM8ECCMIB: View SNMP OID List / Download MIB

VENDOR: SCHNEIDER ELECTRIC


 Home MIB: PM8ECCMIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 schneiderElectric 1.3.6.1.4.1.3833
           transparentFactoryEthernet 1.3.6.1.4.1.3833.1
               equipmentProfile 1.3.6.1.4.1.3833.1.7
                   tfProducts 1.3.6.1.4.1.3833.1.7.255
                           ecc 1.3.6.1.4.1.3833.1.7.255.15
                                 pm8ecc 1.3.6.1.4.1.3833.1.7.255.15.1
                                     metering 1.3.6.1.4.1.3833.1.7.255.15.1.1
                                         systemWiringTypeTable 1.3.6.1.4.1.3833.1.7.255.15.1.1.1 no-access
The wiring system type of the host meter.
                                             systemWiringTypeEntry 1.3.6.1.4.1.3833.1.7.255.15.1.1.1.1 no-access
Host Meter System Wiring Type
                                                 swtIndex 1.3.6.1.4.1.3833.1.7.255.15.1.1.1.1.1 integer read-only
System Wiring Type Table Index
                                                 swtWiringType 1.3.6.1.4.1.3833.1.7.255.15.1.1.1.1.2 integer read-only
Single Phase Line to Neutral 2 Wire 1CT 1PT is '10' Single Phase Line to Line 2 Wire 1CT 1PT is '11' Single Phase 3-Wire 3 wire 2CT 2PT is '12' Three Phase 3 Wire 2CT 2PT is '30' Three Phase 3 Wire 3CT 2PT is '31' Three Phase 3 Wire 1CT 2PT is '32' Three Phase 4 Wire 3CT 3PT is '40' Three Phase 4 Wire 3CT 2PT is '42' Three Phase 4 Wire 1CT 3PT is '44'
                                         loadCurrentTable 1.3.6.1.4.1.3833.1.7.255.15.1.1.2 no-access
Host Meter Load Current Table
                                             loadCurrentEntry 1.3.6.1.4.1.3833.1.7.255.15.1.1.2.1 no-access
Host Meter Load Current Table
                                                 lcIndex 1.3.6.1.4.1.3833.1.7.255.15.1.1.2.1.1 integer read-only
Load Current Table Index
                                                 lcIa 1.3.6.1.4.1.3833.1.7.255.15.1.1.2.1.2 octet string read-only
Host Meter Load Current Phase A Units = A (Amps)
                                                 lcIb 1.3.6.1.4.1.3833.1.7.255.15.1.1.2.1.3 octet string read-only
Host Meter Load Current Phase B Units = A (Amps)
                                                 lcIc 1.3.6.1.4.1.3833.1.7.255.15.1.1.2.1.4 octet string read-only
Host Meter Load Current Phase C Units = A (Amps)
                                                 lcIAvg 1.3.6.1.4.1.3833.1.7.255.15.1.1.2.1.5 octet string read-only
Host Meter Load Current 3 Phase Average Units = A (Amps)
                                         powerTable 1.3.6.1.4.1.3833.1.7.255.15.1.1.3 no-access
Host Meter Power Table
                                             powerEntry 1.3.6.1.4.1.3833.1.7.255.15.1.1.3.1 no-access
Host Meter Power Table
                                                 pIndex 1.3.6.1.4.1.3833.1.7.255.15.1.1.3.1.1 integer read-only
Power Table Index
                                                 pReal 1.3.6.1.4.1.3833.1.7.255.15.1.1.3.1.2 octet string read-only
Host Meter Real Power Units = kW
                                                 pReactive 1.3.6.1.4.1.3833.1.7.255.15.1.1.3.1.3 octet string read-only
Host Meter Reactive Power Units = kVAR
                                                 pApparent 1.3.6.1.4.1.3833.1.7.255.15.1.1.3.1.4 octet string read-only
Host Meter Apparent Power Units = kVA
                                         powerFactorTable 1.3.6.1.4.1.3833.1.7.255.15.1.1.4 no-access
Host Meter Power Factor Table
                                             powerFactorEntry 1.3.6.1.4.1.3833.1.7.255.15.1.1.4.1 no-access
Host Meter Power Factor Table
                                                 pfIndex 1.3.6.1.4.1.3833.1.7.255.15.1.1.4.1.1 integer read-only
Power Factor Table Index
                                                 pfPowerFactorTotal 1.3.6.1.4.1.3833.1.7.255.15.1.1.4.1.2 octet string read-only
Host Meter 3 Phase Total Power Factor
                                                 pfPowerFactorDescription 1.3.6.1.4.1.3833.1.7.255.15.1.1.4.1.3 octet string read-only
Describes the current power factor Lead/Lag for IEEE mode Cap/Ind for IEC mode
                                         voltageTable 1.3.6.1.4.1.3833.1.7.255.15.1.1.5 no-access
Host Meter Voltage Table
                                             voltageEntry 1.3.6.1.4.1.3833.1.7.255.15.1.1.5.1 no-access
Host Meter Voltage Table
                                                 vIndex 1.3.6.1.4.1.3833.1.7.255.15.1.1.5.1.1 integer read-only
Voltage Table Index
                                                 vVab 1.3.6.1.4.1.3833.1.7.255.15.1.1.5.1.2 octet string read-only
Host Meter Voltage Line A to Line B Units = V (Volts)
                                                 vVbc 1.3.6.1.4.1.3833.1.7.255.15.1.1.5.1.3 octet string read-only
Host Meter Voltage Line B to Line C Units = V (Volts)
                                                 vVca 1.3.6.1.4.1.3833.1.7.255.15.1.1.5.1.4 octet string read-only
Host Meter Voltage Line C to Line A Units = V (Volts)
                                                 vVllAvg 1.3.6.1.4.1.3833.1.7.255.15.1.1.5.1.5 octet string read-only
Host Meter Voltage Line to Line Average Voltage Units = V (Volts)
                                                 vVan 1.3.6.1.4.1.3833.1.7.255.15.1.1.5.1.6 octet string read-only
Host Meter Voltage Line A to Neutral Units = V (Volts)
                                                 vVbn 1.3.6.1.4.1.3833.1.7.255.15.1.1.5.1.7 octet string read-only
Host Meter Voltage Line B to Neutral Units = V (Volts)
                                                 vVcn 1.3.6.1.4.1.3833.1.7.255.15.1.1.5.1.8 octet string read-only
Host Meter Voltage Line C to Neutral Units = V (Volts)
                                                 vVlnAvg 1.3.6.1.4.1.3833.1.7.255.15.1.1.5.1.9 octet string read-only
Host Meter Voltage Line to Neutral 3 Phase Average Units = V (Volts)
                                         frequencyTable 1.3.6.1.4.1.3833.1.7.255.15.1.1.6 no-access
Host Meter Frequency Table
                                             frequencyEntry 1.3.6.1.4.1.3833.1.7.255.15.1.1.6.1 no-access
Host Meter Frequency Table
                                                 fIndex 1.3.6.1.4.1.3833.1.7.255.15.1.1.6.1.1 integer read-only
Frequency Table Index
                                                 fFrequency 1.3.6.1.4.1.3833.1.7.255.15.1.1.6.1.2 octet string read-only
Host Meter Frequency Units = Hz
                                         currentDemandTable 1.3.6.1.4.1.3833.1.7.255.15.1.1.7 no-access
Host Meter Current Demand Table
                                             currentDemandEntry 1.3.6.1.4.1.3833.1.7.255.15.1.1.7.1 no-access
Host Meter Current Demand Table
                                                 cdIndex 1.3.6.1.4.1.3833.1.7.255.15.1.1.7.1.1 integer read-only
Demand Current Table Index
                                                 cdPhase 1.3.6.1.4.1.3833.1.7.255.15.1.1.7.1.2 octet string read-only
Host Meter Current Demand Phase Name
                                                 cdPresentCurrentDemand 1.3.6.1.4.1.3833.1.7.255.15.1.1.7.1.3 octet string read-only
Host Meter Present Demand Current Units = A (Amps)
                                                 cdPeakCurrentDemand 1.3.6.1.4.1.3833.1.7.255.15.1.1.7.1.4 octet string read-only
Host Meter Peak Current Demand Units = A (Amps)
                                                 cdLastCurrentDemand 1.3.6.1.4.1.3833.1.7.255.15.1.1.7.1.5 octet string read-only
Host Meter Current Demand Last Interval Units = A (Amps)
                                                 cdPeakDateTime 1.3.6.1.4.1.3833.1.7.255.15.1.1.7.1.6 octet string read-only
Host Meter Peak Current Demand Date and Time
                                                 cdResetDateTime 1.3.6.1.4.1.3833.1.7.255.15.1.1.7.1.7 octet string read-only
Host Meter Date and Time of Demand Current Reset
                                                 cdPhaseEnum 1.3.6.1.4.1.3833.1.7.255.15.1.1.7.1.8 integer read-only
Host Meter Current Demand Phase Enumeration: 'currentPhaseA': 1, 'currentPhaseC': 3, 'currentPhaseB': 2.
                                         powerDemandTable 1.3.6.1.4.1.3833.1.7.255.15.1.1.8 no-access
Host Meter Power Demand
                                             powerDemandEntry 1.3.6.1.4.1.3833.1.7.255.15.1.1.8.1 no-access
Host Meter Power Demand Table
                                                 pdIndex 1.3.6.1.4.1.3833.1.7.255.15.1.1.8.1.1 integer read-only
Power Demand Table Index
                                                 pdComponent 1.3.6.1.4.1.3833.1.7.255.15.1.1.8.1.2 octet string read-only
Host Meter Power Demand Component Units: Real = kW Reacitve = kVAR Apparent = kVA
                                                 pdPresentPowerDemand 1.3.6.1.4.1.3833.1.7.255.15.1.1.8.1.3 octet string read-only
Host Meter Present Demand Power
                                                 pdPeakPowerDemand 1.3.6.1.4.1.3833.1.7.255.15.1.1.8.1.4 octet string read-only
Host Meter Peak Power Demand
                                                 pdLastPowerDemand 1.3.6.1.4.1.3833.1.7.255.15.1.1.8.1.5 octet string read-only
Host Meter Power Demand Last Interval
                                                 pdPeakDateTime 1.3.6.1.4.1.3833.1.7.255.15.1.1.8.1.6 octet string read-only
Host Meter Peak Power Demand Date and Time
                                                 pdResetDateTime 1.3.6.1.4.1.3833.1.7.255.15.1.1.8.1.7 octet string read-only
Host Meter Date and Time of Power Demand Reset
                                                 pdComponentEnum 1.3.6.1.4.1.3833.1.7.255.15.1.1.8.1.8 integer read-only
Host Meter Power Demand Component Enumeration: 'reactivePower': 2, 'apparentPower': 3, 'realPower': 1.
                                         energyTable 1.3.6.1.4.1.3833.1.7.255.15.1.1.9 no-access
Host Meter Energy Table
                                             energyEntry 1.3.6.1.4.1.3833.1.7.255.15.1.1.9.1 no-access
Host Meter Energy Table
                                                 eIndex 1.3.6.1.4.1.3833.1.7.255.15.1.1.9.1.1 integer read-only
Energy Table Index
                                                 eRealEnergy 1.3.6.1.4.1.3833.1.7.255.15.1.1.9.1.2 octet string read-only
Host Meter Real Energy Units = kWh
                                                 eDateTimeRealEnergyReset 1.3.6.1.4.1.3833.1.7.255.15.1.1.9.1.3 octet string read-only
Host Meter Date and Time Real Energy Accumulation was reset
                                                 eReactiveEnergy 1.3.6.1.4.1.3833.1.7.255.15.1.1.9.1.4 octet string read-only
Host Meter Reactive Energy Units = kVARh
                                                 eDateTimeReactiveEnergyReset 1.3.6.1.4.1.3833.1.7.255.15.1.1.9.1.5 octet string read-only
Host Meter Date and Time Reative Energy Accumulation was reset
                                                 eApparentEnergy 1.3.6.1.4.1.3833.1.7.255.15.1.1.9.1.6 octet string read-only
Host Meter Apparent Energy Units = kVAh
                                                 eDateTimeApparentEnergyReset 1.3.6.1.4.1.3833.1.7.255.15.1.1.9.1.7 octet string read-only
Host Meter Date and Time Reactive Energy Accumulation was reset
                                     alarms 1.3.6.1.4.1.3833.1.7.255.15.1.2
                                         alarmConfigurationTable 1.3.6.1.4.1.3833.1.7.255.15.1.2.1 no-access
Displays the current configuration of the Host Meter On-board alarms
                                             alarmConfigurationEntry 1.3.6.1.4.1.3833.1.7.255.15.1.2.1.1 no-access
Contains configuration information for the Host Meter On-board Alarms
                                                 acIndex 1.3.6.1.4.1.3833.1.7.255.15.1.2.1.1.1 integer read-only
Alarm Configuration Table Index
                                                 acPosition 1.3.6.1.4.1.3833.1.7.255.15.1.2.1.1.2 integer read-only
Indicates the position of the alarm. 1 - 74
                                                 acAlarmLabel 1.3.6.1.4.1.3833.1.7.255.15.1.2.1.1.3 alarmlabel read-only
The name of the alarm (user configurable)
                                                 acEnabled 1.3.6.1.4.1.3833.1.7.255.15.1.2.1.1.4 integer read-only
Indicates whether the alarm is enabled or not. 0 = Disabled 255 = Enabled
                                                 acStatus 1.3.6.1.4.1.3833.1.7.255.15.1.2.1.1.5 integer read-only
Indicates whether the alarm is active. 0 = Inactive 1 = Active
                                                 acCounter 1.3.6.1.4.1.3833.1.7.255.15.1.2.1.1.6 integer read-only
Indicates the number of times the alarm has been activated. Note: This counter resets at 32767
                                                 acPriority 1.3.6.1.4.1.3833.1.7.255.15.1.2.1.1.7 integer read-only
The priority of the alarm. 0 = No Priority 1 = Low Priority 2 = Medium Priority 3 = High Priority
                                                 acType 1.3.6.1.4.1.3833.1.7.255.15.1.2.1.1.8 alarmtype read-only
Indicates the type of the alarm.
                                                 acAlarmList1 1.3.6.1.4.1.3833.1.7.255.15.1.2.1.1.9 integer read-only
Used for combinatorial type alarms - The position of the first alarm that is used to evaluate the alarm state.
                                                 acAlarmList2 1.3.6.1.4.1.3833.1.7.255.15.1.2.1.1.10 integer read-only
Used for combinatorial type alarms - The position of the second alarm that is used to evaluate the alarm state.
                                                 acAlarmList3 1.3.6.1.4.1.3833.1.7.255.15.1.2.1.1.11 integer read-only
Used for combinatorial type alarms - The position of the third alarm that is used to evaluate the alarm state.
                                                 acAlarmList4 1.3.6.1.4.1.3833.1.7.255.15.1.2.1.1.12 integer read-only
Used for combinatorial type alarms - The position of the fourth alarm that is used to evaluate the alarm state.
                                         alarmSummaryBitmapsTable 1.3.6.1.4.1.3833.1.7.255.15.1.2.2 no-access
Indicates the state of the Host Meter On-Board Alarms
                                             alarmSummaryBitmapsEntry 1.3.6.1.4.1.3833.1.7.255.15.1.2.2.1 no-access
Indicates the status of the Host Meter On-Board Alarms
                                                 alSumIndex 1.3.6.1.4.1.3833.1.7.255.15.1.2.2.1.1 integer read-only
Alarm Summary Bitmap Table Index
                                                 alSumAlarms1to16 1.3.6.1.4.1.3833.1.7.255.15.1.2.2.1.2 octet string read-only
Indicates the status of Alarms 1 - 16 (16-bits, bit-0 = Alarm 1)
                                                 alSumAlarms17to32 1.3.6.1.4.1.3833.1.7.255.15.1.2.2.1.3 octet string read-only
Indicates the status of Alarms 17 - 32 (16-bits, bit-0 = Alarm 17)
                                                 alSumAlarms33to48 1.3.6.1.4.1.3833.1.7.255.15.1.2.2.1.4 octet string read-only
Indicates the status of Alarms 33 - 48 (16-bits, bit-0 = Alarm 33)
                                                 alSumAlarms49to64 1.3.6.1.4.1.3833.1.7.255.15.1.2.2.1.5 octet string read-only
Indicates the status of Alarms 49 - 64 (16-bits, bit-0 = Alarm 49)
                                                 alSumAlarms65to74 1.3.6.1.4.1.3833.1.7.255.15.1.2.2.1.6 octet string read-only
Indicates the status of Alarms 65 - 74 (16-bits, bit-0 = Alarm 65, bit-9 = Alarm 74)
                                         alarmCountersTable 1.3.6.1.4.1.3833.1.7.255.15.1.2.3 no-access
Host Meter On-Board Alarm Counters
                                             alarmCountersEntry 1.3.6.1.4.1.3833.1.7.255.15.1.2.3.1 no-access
Host Meter On-Board Alarm Counters
                                                 alCntIndex 1.3.6.1.4.1.3833.1.7.255.15.1.2.3.1.1 integer read-only
Alarm Counters Table Index
                                                 alCntAlarmPosition 1.3.6.1.4.1.3833.1.7.255.15.1.2.3.1.2 integer read-only
The Host Meter Alarm Position
                                                 alCntCount 1.3.6.1.4.1.3833.1.7.255.15.1.2.3.1.3 integer read-only
The number of times the Host Meter On-Board alarm has transitioned from an inactive state to an active state
                                     io 1.3.6.1.4.1.3833.1.7.255.15.1.3
                                         ioOptionIDTable 1.3.6.1.4.1.3833.1.7.255.15.1.3.1 no-access
I/O Option Module Installed on the Host Meter
                                             ioOptionIDEntry 1.3.6.1.4.1.3833.1.7.255.15.1.3.1.1 no-access
I/O Option Card Installed On-board the Host Meter
                                                 ioIDIndex 1.3.6.1.4.1.3833.1.7.255.15.1.3.1.1.1 integer read-only
I/O Installed Option ID Table Index
                                                 ioIDInstalledOptionSlot1 1.3.6.1.4.1.3833.1.7.255.15.1.3.1.1.2 integer read-only
0 = Not Installed 1 = Unused 2 = IO22 3 = IO26 4 = IO 2222 Enumeration: 'unused': 1, 'io-26': 3, 'io-22': 2, 'io-2222': 4.
                                                 ioIDInstalledOptionSlot2 1.3.6.1.4.1.3833.1.7.255.15.1.3.1.1.3 integer read-only
0 = Not Installed 1 = Unused 2 = IO22 3 = IO26 4 = IO 2222 Enumeration: 'unused': 1, 'io-26': 3, 'io-22': 2, 'io-2222': 4.
                                         ioConfigurationTable 1.3.6.1.4.1.3833.1.7.255.15.1.3.2 no-access
Displays the current I/O configuration for each I/O point
                                             ioConfigurationEntry 1.3.6.1.4.1.3833.1.7.255.15.1.3.2.1 no-access
Contains configuration information for the Host Meter On-board I/O
                                                 iocIndex 1.3.6.1.4.1.3833.1.7.255.15.1.3.2.1.1 integer read-only
I/O Configuration Table Index
                                                 iocPointNumber 1.3.6.1.4.1.3833.1.7.255.15.1.3.2.1.2 integer read-only
The point number for this I/O Point
                                                 iocLabel 1.3.6.1.4.1.3833.1.7.255.15.1.3.2.1.3 iopointlabel read-only
The name of the I/O Point (user configurable)
                                                 iocStateOrValue 1.3.6.1.4.1.3833.1.7.255.15.1.3.2.1.4 octet string read-only
Displays the current value for the I/O Point Digial I/O: 1 = Active or 0 = Inactive Analog I/O: Scaled input/output value
                                                 iocPointType 1.3.6.1.4.1.3833.1.7.255.15.1.3.2.1.5 iopointtype read-only
The type of I/O at this point
                                                 iocMode 1.3.6.1.4.1.3833.1.7.255.15.1.3.2.1.6 integer read-only
For Digital Inputs and Outputs this object is always 0 indicating Discrete. For Analog Inputs and Outputs this object indicates the range of analog I/O values (used without units) 0 = 0 1 1 = 0 5 2 = 0 10 3 = 0 20 4 = 1 5 5 = 4 20 6 = -5 5 7 = -10 10 8 = -100 100 9 = User defined (values default to 0)
                                                 iocType 1.3.6.1.4.1.3833.1.7.255.15.1.3.2.1.7 integer read-only
For Digital Inputs this object indicates input type 1 = Unused 2 = AC/DC For Digital Outputs this object indicates output type 1 = solid state relay 2 = electromechanical relay For Analog Inputs and Outputs this object indicates the digital resolution of the I/O hardware. 0 = 8-Bit, unipolar 1 = 10-Bit, unipolar 2 = 12-Bit, unipolar 3 = 14-Bit, unipolar 4 = 16-Bit, unipolar 5 = 16-Bit, bipolar with sign 6 = reserved 7 = reserved 8 = Resolution for IO2222 Voltage range 0 - 4000 9 = Resolution for IO2222 Current range 800 - 4000
                                                 iocCount 1.3.6.1.4.1.3833.1.7.255.15.1.3.2.1.8 octet string read-only
Number of times digital I/O point has transitioned from OFF to ON
                                         ioStatusBitmapsTable 1.3.6.1.4.1.3833.1.7.255.15.1.3.3 no-access
Host Meter I/O Status Bitmaps
                                             ioStatusBitmapsEntry 1.3.6.1.4.1.3833.1.7.255.15.1.3.3.1 no-access
Host Meter On-Board I/O Status Bitmaps
                                                 ioStatIndex 1.3.6.1.4.1.3833.1.7.255.15.1.3.3.1.1 integer read-only
I/O Summary Bitmaps Table Index
                                                 ioStatSummaryBitmap 1.3.6.1.4.1.3833.1.7.255.15.1.3.3.1.2 octet string read-only
Indicates the Status of the Host Meter I/O Points Bit-0 = I/O Point 1 Bit-1 = I/O Point 2 ... Bit-17 = I/O Point 18
                                     meterSystem 1.3.6.1.4.1.3833.1.7.255.15.1.4
                                         meterIdentificationTable 1.3.6.1.4.1.3833.1.7.255.15.1.4.1 no-access
Host Meter Identification
                                             meterIdentificationEntry 1.3.6.1.4.1.3833.1.7.255.15.1.4.1.1 no-access
Host Meter Identification
                                                 midIndex 1.3.6.1.4.1.3833.1.7.255.15.1.4.1.1.1 integer read-only
Meter Identification Table Index
                                                 midSerialNumber 1.3.6.1.4.1.3833.1.7.255.15.1.4.1.1.2 integer read-only
Host meter 32 bit Serial Number
                                                 midFirmwareVersion 1.3.6.1.4.1.3833.1.7.255.15.1.4.1.1.3 octet string read-only
Host Meter Firmware Version
                                                 midModelNumber 1.3.6.1.4.1.3833.1.7.255.15.1.4.1.1.4 octet string read-only
Host Meter Model Number
                                                 midDeviceName 1.3.6.1.4.1.3833.1.7.255.15.1.4.1.1.5 octet string read-only
Host Meter Label plus Nameplate
                                     trapVariables 1.3.6.1.4.1.3833.1.7.255.15.1.5
                                         alarmDateAndTime 1.3.6.1.4.1.3833.1.7.255.15.1.5.1 octet string read-only
The Date and Time of the alarm state change.
                                         alarmLabel 1.3.6.1.4.1.3833.1.7.255.15.1.5.2 octet string read-only
The Descriptive Label given to the alarm
                                         alarmState 1.3.6.1.4.1.3833.1.7.255.15.1.5.3 octet string read-only
The state of the Alarm - pickup, dropout, unary, diagnostic
                                         alarmValue 1.3.6.1.4.1.3833.1.7.255.15.1.5.4 integer read-only
The value of the alarm when it changed state.
                                         alarmPriority 1.3.6.1.4.1.3833.1.7.255.15.1.5.5 integer read-only
The priority defined for the alarm. Enumeration: 'highPriority': 1, 'lowPriority': 3, 'mediumPriority': 2.
                                     mibVersion 1.3.6.1.4.1.3833.1.7.255.15.1.6 octet string read-only
This is the current version of the MIB
                                       pm8OnBoardAlarmP1 1.3.6.1.4.1.3833.1.7.255.15.10.1
Indicates the Host Meter On-Board Alarm system has detected a state change of an enabled alarm with a priority of 1
                                       pm8OnBoardAlarmP2 1.3.6.1.4.1.3833.1.7.255.15.10.2
Indicates the Host Meter On-Board Alarm system has detected a state change of an enabled alarm with a priority of 2
                                       pm8OnBoardAlarmP3 1.3.6.1.4.1.3833.1.7.255.15.10.3
Indicates the Host Meter On-Board Alarm system has detected a state change of an enabled alarm with a priority of 3