Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 pm 1.3.6.1.4.1.10418.17
This module defines the Avocent MIB extensions to PM-PDU products.
       pmProducts 1.3.6.1.4.1.10418.17.1
           pm1024 1.3.6.1.4.1.10418.17.1.1
           pm2003 1.3.6.1.4.1.10418.17.1.2
           pm2006 1.3.6.1.4.1.10418.17.1.3
           pm2024 1.3.6.1.4.1.10418.17.1.4
           pm3003 1.3.6.1.4.1.10418.17.1.5
           pm3006 1.3.6.1.4.1.10418.17.1.6
           pm3024 1.3.6.1.4.1.10418.17.1.7
           pm1010 1.3.6.1.4.1.10418.17.1.8
           pm2010 1.3.6.1.4.1.10418.17.1.9
           pm3010 1.3.6.1.4.1.10418.17.1.10
           pm1020 1.3.6.1.4.1.10418.17.1.11
           pm2020 1.3.6.1.4.1.10418.17.1.12
           pm3020 1.3.6.1.4.1.10418.17.1.13
       pmManagement 1.3.6.1.4.1.10418.17.2
           pmAppliance 1.3.6.1.4.1.10418.17.2.1
               pmHostName 1.3.6.1.4.1.10418.17.2.1.1 displaystring read-only
The appliance name
               pmProductModel 1.3.6.1.4.1.10418.17.2.1.2 displaystring read-only
The appliance product model
               pmPartNumber 1.3.6.1.4.1.10418.17.2.1.3 displaystring read-only
The part number of this appliance as shown on the label attached or imprinted on the appliance.
               pmSerialNumber 1.3.6.1.4.1.10418.17.2.1.4 displaystring read-only
The serial number of this appliance as shown on the label attached or imprinted on the appliance.
               pmEIDNumber 1.3.6.1.4.1.10418.17.2.1.5 displaystring read-only
The electronic ID number (EID) of this appliance as shown on the label attached or imprinted on the appliance.
               pmBootcodeVersion 1.3.6.1.4.1.10418.17.2.1.6 displaystring read-only
The version of the bootcode of this appliance.
               pmFirmwareVersion 1.3.6.1.4.1.10418.17.2.1.7 displaystring read-only
The version of the firmware of this appliance.
               pmReboot 1.3.6.1.4.1.10418.17.2.1.9 integer read-write
A set value of reboot(2) will reboot the appliance. noAction(1) = always returned in a GET. Does nothing if SET. reboot(2) = when SET the appliance immediately reboots. Enumeration: 'reboot': 2, 'noAction': 1.
           pmSessions 1.3.6.1.4.1.10418.17.2.2
               pmActiveSessionsNumberOfSession 1.3.6.1.4.1.10418.17.2.2.1 integer32 read-only
Number of active sessions.
               pmActiveSessionsTable 1.3.6.1.4.1.10418.17.2.2.2 no-access
This table contains the list of active sessions.
                   pmActiveSessionsTableEntry 1.3.6.1.4.1.10418.17.2.2.2.1 no-access
each entry has the information about the active session
                       pmActiveSessionsTableIndex 1.3.6.1.4.1.10418.17.2.2.2.1.1 interfaceindexorzero read-only
A unique index representing an entry in this table.
                       pmActiveSessionsTableUser 1.3.6.1.4.1.10418.17.2.2.2.1.2 displaystring read-only
The name of the user that opens this session.
                       pmActiveSessionsTableGroup 1.3.6.1.4.1.10418.17.2.2.2.1.3 displaystring read-only
The name of the group that the user belongs to.
                       pmActiveSessionsTableType 1.3.6.1.4.1.10418.17.2.2.2.1.4 displaystring read-only
The session type.
                       pmActiveSessionsTableConnection 1.3.6.1.4.1.10418.17.2.2.2.1.5 displaystring read-only
Connection type.
                       pmActiveSessionsTableSessionTime 1.3.6.1.4.1.10418.17.2.2.2.1.6 displaystring read-only
Time of the session
                       pmActiveSessionsTableFrom 1.3.6.1.4.1.10418.17.2.2.2.1.7 displaystring read-only
The source IP address of the session.
                       pmActiveSessionsTableKill 1.3.6.1.4.1.10418.17.2.2.2.1.8 integer read-write
A set value of killSession(2) will kill the session. noAction(1) = always returned in a GET. Does nothing if SET. killSession(2)= when SET the appliance immediately kills the session. Enumeration: 'noAction': 1, 'killSession': 2.
           pmPowerMgmt 1.3.6.1.4.1.10418.17.2.5
               pmPowerMgmtNumSerialPorts 1.3.6.1.4.1.10418.17.2.5.1 integer32 read-only
The number of Serial Ports that has PDU connected on the appliance.
               pmPowerMgmtSerialTable 1.3.6.1.4.1.10418.17.2.5.2 no-access
Information about each serial port thas has PDU connect.
                   pmPowerMgmtSerialTableEntry 1.3.6.1.4.1.10418.17.2.5.2.1 no-access
Information about each serial port thas has PDU connect.
                       pmPowerMgmtSerialTableIndex 1.3.6.1.4.1.10418.17.2.5.2.1.1 interfaceindex read-only
The index of the register.
                       pmPowerMgmtSerialTablePortNumber 1.3.6.1.4.1.10418.17.2.5.2.1.2 integer32 read-only
The number of the serial port when the PDU is connected.
                       pmPowerMgmtSerialTableDeviceName 1.3.6.1.4.1.10418.17.2.5.2.1.3 displaystring read-only
The device name of this serial port.
                       pmPowerMgmtSerialTableNumberPDUs 1.3.6.1.4.1.10418.17.2.5.2.1.4 integer32 read-only
Total number of units connected in this serial port.
                       pmPowerMgmtSerialTableBuzzer 1.3.6.1.4.1.10418.17.2.5.2.1.10 integer32 read-write
set/get buzzer(s) on or off for the chain. Returns 0 if not supported.
                       pmPowerMgmtSerialTableSyslog 1.3.6.1.4.1.10418.17.2.5.2.1.11 integer32 read-write
set/get syslog on or off for the chain. Returns 0 if not supported.
                       pmPowerMgmtSerialTableOverCurrent 1.3.6.1.4.1.10418.17.2.5.2.1.12 integer32 read-write
set/get over current proctection on or off for the chain. Returns 0 if not supported.
                       pmPowerMgmtSerialTableCycleInterval 1.3.6.1.4.1.10418.17.2.5.2.1.13 integer32 read-write
set/get cycle interval for the chain in whole seconds. Returns 0 if not supported.
                       pmPowerMgmtSerialTablePollRate 1.3.6.1.4.1.10418.17.2.5.2.1.14 integer32 read-write
set/get the poll rate for the chain in whole seconds. Returns 0 if not supported.
                       pmPowerMgmtSerialTablePassWord 1.3.6.1.4.1.10418.17.2.5.2.1.15 displaystring read-write
set the global password for admin user
                       pmPowerMgmtSerialTableSave 1.3.6.1.4.1.10418.17.2.5.2.1.20 integer read-write
noAction(1) = always returned in a GET. Does nothing if SET. save(2) = when SET the save command is sent to PDU. Enumeration: 'save': 2, 'noAction': 1.
                       pmPowerMgmtSerialTableRestore 1.3.6.1.4.1.10418.17.2.5.2.1.21 integer read-write
noAction(1) = always returned in a GET. Does nothing if SET. restore(2) = when SET the restore command is sent to PDU. Enumeration: 'restore': 2, 'noAction': 1.
               pmPowerMgmtPDUTable 1.3.6.1.4.1.10418.17.2.5.3 no-access
This table contains the list of detected PDUs.
                   pmPowerMgmtPDUTableEntry 1.3.6.1.4.1.10418.17.2.5.3.1 no-access
each entry has the information about the PDU.
                       pmPowerMgmtPDUTablePortNumber 1.3.6.1.4.1.10418.17.2.5.3.1.1 interfaceindex read-only
Number of serial port when the PDU is connected.
                       pmPowerMgmtPDUTablePduIndex 1.3.6.1.4.1.10418.17.2.5.3.1.2 interfaceindexorzero read-only
A PDU position in the chain.
                       pmPowerMgmtPDUTablePduId 1.3.6.1.4.1.10418.17.2.5.3.1.3 displaystring read-write
PDU identification.
                       pmPowerMgmtPDUTablePortName 1.3.6.1.4.1.10418.17.2.5.3.1.4 displaystring read-only
Name of serial port when the PDU is connected.
                       pmPowerMgmtPDUTableModel 1.3.6.1.4.1.10418.17.2.5.3.1.5 displaystring read-only
Model of the PDU. Returns N/A if not applicable.
                       pmPowerMgmtPDUTableVendor 1.3.6.1.4.1.10418.17.2.5.3.1.6 displaystring read-only
Vendor of the PDU. Returns N/A if not applicable.
                       pmPowerMgmtPDUTableFirmwareVersion 1.3.6.1.4.1.10418.17.2.5.3.1.7 displaystring read-only
Version of the PDU firmware. Returns N/A if not applicable.
                       pmPowerMgmtPDUTableNumberOfOutlets 1.3.6.1.4.1.10418.17.2.5.3.1.8 integer32 read-only
Number of outlets of the PDU.
                       pmPowerMgmtPDUTableCurrentNOS 1.3.6.1.4.1.10418.17.2.5.3.1.9 integer32 read-only
Number of current sensors in the PDU.
                       pmPowerMgmtPDUTableCurrent1Value 1.3.6.1.4.1.10418.17.2.5.3.1.10 integer32 read-only
Current of the sensor 1 in this PDU unit in AMP. The value of this object is the actual current in AMP * 10. You need to translate the readed value (Ex. : value is 5, the current is 0.5 AMP.). This OID is obsoleted. The value can be retrieved from pmPowerMgmtPDUTableCurrentValue, pmPowerMgmtPhasesTableCurrentValue, or pmPowerMgmtOutletsTableCurrentValue
                       pmPowerMgmtPDUTableCurrent1Max 1.3.6.1.4.1.10418.17.2.5.3.1.11 integer32 read-write
Maximum current of the sensor 1 in this PDU unit in AMP. When the PDU does not have support for maximum value, the value will be 0. The value of this object is the actual current in AMP * 10. You need to translate the readed value (Ex. : value is 5, the current is 0.5 AMP.) Clear this value, set it with Zero value. This OID is obsoleted. The value can be retrieved from pmPowerMgmtPDUTableCurrentMax, pmPowerMgmtPhasesTableCurrentMax, or pmPowerMgmtOutletsTableCurrentMax
                       pmPowerMgmtPDUTableCurrent2Value 1.3.6.1.4.1.10418.17.2.5.3.1.12 integer32 read-only
Current of the sensor 2 in this PDU unit in AMP. The value of this object is the actual current in AMP * 10. You need to translate the readed value (Ex. : value is 5, the current is 0.5 AMP.). This OID is obsoleted. The value can be retrieved from pmPowerMgmtPDUTableCurrentValue, pmPowerMgmtPhasesTableCurrentValue, or pmPowerMgmtOutletsTableCurrentValue
                       pmPowerMgmtPDUTableCurrent2Max 1.3.6.1.4.1.10418.17.2.5.3.1.13 integer32 read-write
Maximum current of the sensor 2 in this PDU unit in AMP. When the PDU does not have support for maximum value, the value will be 0. The value of this object is the actual current in AMP * 10. You need to translate the readed value (Ex. : value is 5, the current is 0.5 AMP.) Clear this value, set it with Zero value. This OID is obsoleted. The value can be retrieved from pmPowerMgmtPDUTableCurrentMax, pmPowerMgmtPhasesTableCurrentMax, or pmPowerMgmtOutletsTableCurrentMax
                       pmPowerMgmtPDUTableCurrent3Value 1.3.6.1.4.1.10418.17.2.5.3.1.14 integer32 read-only
Current of the sensor 3 in this PDU unit in AMP. The value of this object is the actual current in AMP * 10. You need to translate the readed value (Ex. : value is 5, the current is 0.5 AMP.) This OID is obsoleted. The value can be retrieved from pmPowerMgmtPDUTableCurrentValue, pmPowerMgmtPhasesTableCurrentValue, or pmPowerMgmtOutletsTableCurrentValue
                       pmPowerMgmtPDUTableCurrent3Max 1.3.6.1.4.1.10418.17.2.5.3.1.15 integer32 read-write
Maximum current of the sensor 3 in this PDU unit in AMP. When the PDU does not have support for maximum value, the value will be 0. The value of this object is the actual current in AMP * 10. You need to translate the readed value (Ex. : value is 5, the current is 0.5 AMP.) Clear this value, set it with Zero value. This OID is obsoleted. The value can be retrieved from pmPowerMgmtPDUTableCurrentMax, pmPowerMgmtPhasesTableCurrentMax, or pmPowerMgmtOutletsTableCurrentMax
                       pmPowerMgmtPDUTableTemperatureNOS 1.3.6.1.4.1.10418.17.2.5.3.1.16 integer32 read-only
Number of temperature sensors in the PDU.
                       pmPowerMgmtPDUTableTemperature1Value 1.3.6.1.4.1.10418.17.2.5.3.1.17 integer32 read-only
Temperature of this PM unit in Celsius degrees. The value of this object is the actual temperature in degrees C * 10. You need to translate the readed value (Ex. : value is 240, the temperature is 24 Celsius.) If the temperature measurement is not installed this value will be 0. Valid values are 5 to 999 ( 0.5 to 99.9 Celsius).
                       pmPowerMgmtPDUTableTemperature1Max 1.3.6.1.4.1.10418.17.2.5.3.1.18 integer32 read-write
Maximum temperature detected in this PM unit in Celsius degrees. The value will be Zero when the PDU does not have support for maximum value. The value of this object is the actual temperature in degrees C * 10. You need to translate the readed value (Ex. : value is 240, the temperature is 24 Celsius.) If the temperature measurement is not installed this value will be 0. Valid values are 5 to 999 ( 0.5 to 99.9 Celsius). Set with Zero value to clear the max. temperature.
                       pmPowerMgmtPDUTableTemperature2Value 1.3.6.1.4.1.10418.17.2.5.3.1.19 integer32 read-only
Temperature of this PM unit in Celsius degrees. The value of this object is the actual temperature in degrees C * 10. You need to translate the readed value (Ex. : value is 240, the temperature is 24 Celsius.) If the temperature measurement is not installed this value will be 0. Valid values are 5 to 999 ( 0.5 to 99.9 Celsius).
                       pmPowerMgmtPDUTableTemperature2Max 1.3.6.1.4.1.10418.17.2.5.3.1.20 integer32 read-write
Maximum temperature detected in this PM unit in Celsius degrees. The value will be Zero when the PDU does not have support for maximum value. The value of this object is the actual temperature in degrees C * 10. You need to translate the readed value (Ex. : value is 240, the temperature is 24 Celsius.) If the temperature measurement is not installed this value will be 0. Valid values are 5 to 999 ( 0.5 to 99.9 Celsius). Set with Zero value to clear the max. temperature.
                       pmPowerMgmtPDUTableTemperature3Value 1.3.6.1.4.1.10418.17.2.5.3.1.21 integer32 read-only
Temperature of this PM unit in Celsius degrees. The value of this object is the actual temperature in degrees C * 10. You need to translate the readed value (Ex. : value is 240, the temperature is 24 Celsius.) If the temperature measurement is not installed this value will be 0. Valid values are 5 to 999 ( 0.5 to 99.9 Celsius).
                       pmPowerMgmtPDUTableTemperature3Max 1.3.6.1.4.1.10418.17.2.5.3.1.22 integer32 read-write
Maximum temperature detected in this PM unit in Celsius degrees. The value will be Zero when the PDU does not have support for maximum value. The value of this object is the actual temperature in degrees C * 10. You need to translate the readed value (Ex. : value is 240, the temperature is 24 Celsius.) If the temperature measurement is not installed this value will be 0. Valid values are 5 to 999 ( 0.5 to 99.9 Celsius). Set with Zero value to clear the max. temperature.
                       pmPowerMgmtPDUTableHumidityNOS 1.3.6.1.4.1.10418.17.2.5.3.1.23 integer32 read-only
Number of humidity sensors in the PDU.
                       pmPowerMgmtPDUTableHumidity1Value 1.3.6.1.4.1.10418.17.2.5.3.1.24 integer32 read-only
Humidity of this PM unit . If the humidity measurement is not installed this value will be 0.
                       pmPowerMgmtPDUTableHumidity1Max 1.3.6.1.4.1.10418.17.2.5.3.1.25 integer32 read-write
Maximum humidity detected in this PM unit. If the humidity measurement is not installed or the PDU does not have support for maximum value this value will be 0. Set with Zero value to clear the max. temperature.
                       pmPowerMgmtPDUTableHumidity2Value 1.3.6.1.4.1.10418.17.2.5.3.1.26 integer32 read-only
Humidity of this PM unit . If the humidity measurement is not installed this value will be 0.
                       pmPowerMgmtPDUTableHumidity2Max 1.3.6.1.4.1.10418.17.2.5.3.1.27 integer32 read-write
Maximum humidity detected in this PM unit. If the humidity measurement is not installed or the PDU does not have support for maximum value this value will be 0. Set with Zero value to clear the max. temperature.
                       pmPowerMgmtPDUTableHumidity3Value 1.3.6.1.4.1.10418.17.2.5.3.1.28 integer32 read-only
Humidity of this PM unit . If the humidity measurement is not installed this value will be 0.
                       pmPowerMgmtPDUTableHumidity3Max 1.3.6.1.4.1.10418.17.2.5.3.1.29 integer32 read-write
Maximum humidity detected in this PM unit. If the humidity measurement is not installed or the PDU does not have support for maximum value this value will be 0. Set with Zero value to clear the max. temperature.
                       pmPowerMgmtPDUTableVoltageNOS 1.3.6.1.4.1.10418.17.2.5.3.1.30 integer32 read-only
Number of voltage sensors in the PDU.
                       pmPowerMgmtPDUTableVoltage1Value 1.3.6.1.4.1.10418.17.2.5.3.1.31 integer32 read-only
Voltage of this sensor in this PDU unit. This OID is obsoleted. The value can be retrieved from pmPowerMgmtPDUTableVoltageValue, pmPowerMgmtPhasesTableVoltageValue, or pmPowerMgmtOutletsTableVoltageValue
                       pmPowerMgmtPDUTableVoltage1Max 1.3.6.1.4.1.10418.17.2.5.3.1.32 integer32 read-write
Maximum voltage of this sensor in this PDU unit. Set with Zero value to clear the maximum voltage. This OID is obsoleted. The value can be retrieved from pmPowerMgmtPDUTableVoltageMax, pmPowerMgmtPhasesTableVoltageMax, or pmPowerMgmtOutletsTableVoltageMax
                       pmPowerMgmtPDUTableVoltage2Value 1.3.6.1.4.1.10418.17.2.5.3.1.33 integer32 read-only
Voltage of this sensor in this PDU unit. This OID is obsoleted. The value can be retrieved from pmPowerMgmtPDUTableVoltageValue, pmPowerMgmtPhasesTableVoltageValue, or pmPowerMgmtOutletsTableVoltageValue
                       pmPowerMgmtPDUTableVoltage2Max 1.3.6.1.4.1.10418.17.2.5.3.1.34 integer32 read-write
Maximum voltage of this sensor in this PDU unit. Set with Zero value to clear the maximum voltage. This OID is obsoleted. The value can be retrieved from pmPowerMgmtPDUTableVoltageMax, pmPowerMgmtPhasesTableVoltageMax, or pmPowerMgmtOutletsTableVoltageMax
                       pmPowerMgmtPDUTableVoltage3Value 1.3.6.1.4.1.10418.17.2.5.3.1.35 integer32 read-only
Voltage of this sensor in this PDU unit. This OID is obsoleted. The value can be retrieved from pmPowerMgmtPDUTableVoltageValue, pmPowerMgmtPhasesTableVoltageValue, or pmPowerMgmtOutletsTableVoltageValue
                       pmPowerMgmtPDUTableVoltage3Max 1.3.6.1.4.1.10418.17.2.5.3.1.36 integer32 read-write
Maximum voltage of this sensor in this PDU unit. Set with Zero value to clear the maximum voltage. This OID is obsoleted. The value can be retrieved from pmPowerMgmtPDUTableVoltageMax, pmPowerMgmtPhasesTableVoltageMax, or pmPowerMgmtOutletsTableVoltageMax
                       pmPowerMgmtPDUTableNumberOfPhases 1.3.6.1.4.1.10418.17.2.5.3.1.37 integer32 read-only
Number of phases of the PDU.
                       pmPowerMgmtPDUTableNumberOfBanks 1.3.6.1.4.1.10418.17.2.5.3.1.38 integer32 read-only
Number of banks in the PDU.
                       pmPowerMgmtPDUTableNumberOfSensors 1.3.6.1.4.1.10418.17.2.5.3.1.40 integer32 read-only
Number of sensors in the PDU.
                       pmPowerMgmtPDUTableFactoryDefault 1.3.6.1.4.1.10418.17.2.5.3.1.41 integer read-write
A set value of 2 will set the PDU to factory default settings. noAction(1) = always returned in a GET. Does nothing if SET. reset(2) = when SET the factory default command is sent to the PDU. Enumeration: 'reset': 2, 'noAction': 1.
                       pmPowerMgmtPDUTableColdStartDelay 1.3.6.1.4.1.10418.17.2.5.3.1.42 integer32 read-write
PDUs cold start delay in whole seconds (0-60). Returns 0 if not supported.
                       pmPowerMgmtPDUTableReboot 1.3.6.1.4.1.10418.17.2.5.3.1.43 integer read-write
A set value of power*(2) will send command to PDU. noAction(1) = always returned in a GET. Does nothing if SET. reboot(2) = when SET the reboot command is sent to PDU. Enumeration: 'reboot': 2, 'noAction': 1.
                       pmPowerMgmtPDUTableMaxCurrent 1.3.6.1.4.1.10418.17.2.5.3.1.44 integer32 read-only
Maximum value of current allowed in the PDU (A x 10).
                       pmPowerMgmtPDUTableAlarm 1.3.6.1.4.1.10418.17.2.5.3.1.45 integer read-only
Show the PDU alarm status. Returns 0 if not supported. Enumeration: 'high-critical': 4, 'normal': 1, 'hw-ocp': 3, 'high-warning': 5, 'low-warning': 6, 'blow-fuse': 2, 'low-critical': 7.
                       pmPowerMgmtPDUTableCurrentValue 1.3.6.1.4.1.10418.17.2.5.3.1.50 integer32 read-only
Actual value of current in the PDU (A x 10). Returns 0 if not supported.
                       pmPowerMgmtPDUTableCurrentMax 1.3.6.1.4.1.10418.17.2.5.3.1.51 integer32 read-only
Maximum value of current in the PDU (A x 10). Returns 0 if not supported.
                       pmPowerMgmtPDUTableCurrentMin 1.3.6.1.4.1.10418.17.2.5.3.1.52 integer32 read-only
Minimum value of current in the PDU (A x 10). Returns 0 if not supported.
                       pmPowerMgmtPDUTableCurrentAvg 1.3.6.1.4.1.10418.17.2.5.3.1.53 integer32 read-only
Average value of current in the PDU (A x 10). Returns 0 if not supported.
                       pmPowerMgmtPDUTableCurrentReset 1.3.6.1.4.1.10418.17.2.5.3.1.54 integer read-write
noAction(1) = always returned in a GET. Does nothing if SET. reset(2) = when SET the reset command is sent to PDU. Enumeration: 'reset': 2, 'noAction': 1.
                       pmPowerMgmtPDUTablePowerValue 1.3.6.1.4.1.10418.17.2.5.3.1.60 integer32 read-only
Actual value of power in the PDU (W x 10). Returns 0 if not supported.
                       pmPowerMgmtPDUTablePowerMax 1.3.6.1.4.1.10418.17.2.5.3.1.61 integer32 read-only
Maximum value of power in the PDU (W x 10). Returns 0 if not supported.
                       pmPowerMgmtPDUTablePowerMin 1.3.6.1.4.1.10418.17.2.5.3.1.62 integer32 read-only
Minimum value of power in the PDU (W x 10). Returns 0 if not supported.
                       pmPowerMgmtPDUTablePowerAvg 1.3.6.1.4.1.10418.17.2.5.3.1.63 integer32 read-only
Average value of power in the PDU (W x 10). Returns 0 if not supported.
                       pmPowerMgmtPDUTablePowerReset 1.3.6.1.4.1.10418.17.2.5.3.1.64 integer read-write
noAction(1) = always returned in a GET. Does nothing if SET. reset(2) = when SET the reset command is sent to PDU. Enumeration: 'reset': 2, 'noAction': 1.
                       pmPowerMgmtPDUTablePowerType 1.3.6.1.4.1.10418.17.2.5.3.1.65 integer read-only
Type of power values. Returns 0 if not supported. Enumeration: 'none-sensor': 0, 'estimated': 1, 'measured': 2.
                       pmPowerMgmtPDUTableVoltageValue 1.3.6.1.4.1.10418.17.2.5.3.1.70 integer32 read-only
Actual value of voltage in the PDU (V). Returns 0 if not supported.
                       pmPowerMgmtPDUTableVoltageMax 1.3.6.1.4.1.10418.17.2.5.3.1.71 integer32 read-only
Maximum value of voltage in the PDU (V). Returns 0 if not supported.
                       pmPowerMgmtPDUTableVoltageMin 1.3.6.1.4.1.10418.17.2.5.3.1.72 integer32 read-only
Minimum value of voltage in the PDU (V). Returns 0 if not supported.
                       pmPowerMgmtPDUTableVoltageAvg 1.3.6.1.4.1.10418.17.2.5.3.1.73 integer32 read-only
Average value of voltage in the PDU (V). Returns 0 if not supported.
                       pmPowerMgmtPDUTableVoltageReset 1.3.6.1.4.1.10418.17.2.5.3.1.74 integer read-write
noAction(1) = always returned in a GET. Does nothing if SET. reset(2) = when SET the reset command is sent to PDU. Enumeration: 'reset': 2, 'noAction': 1.
                       pmPowerMgmtPDUTableVoltageType 1.3.6.1.4.1.10418.17.2.5.3.1.75 integer read-only
Type of voltage values. Returns 0 if not supported. Enumeration: 'none-sensor': 0, 'estimated': 1, 'measured': 2.
                       pmPowerMgmtPDUTablePowerFactorValue 1.3.6.1.4.1.10418.17.2.5.3.1.80 integer32 read-only
Actual value of power factor in the PDU (Pf x 100). Returns 0 if not supported.
                       pmPowerMgmtPDUTablePowerFactorMax 1.3.6.1.4.1.10418.17.2.5.3.1.81 integer32 read-only
Maximum value of power factor in the PDU (Pf x 100). Returns 0 if not supported.
                       pmPowerMgmtPDUTablePowerFactorMin 1.3.6.1.4.1.10418.17.2.5.3.1.82 integer32 read-only
Minimum value of power factor in the PDU (Pf x 100). Returns 0 if not supported.
                       pmPowerMgmtPDUTablePowerFactorAvg 1.3.6.1.4.1.10418.17.2.5.3.1.83 integer32 read-only
Average value of power factor in the PDU (Pf x 100). Returns 0 if not supported.
                       pmPowerMgmtPDUTablePowerFactorReset 1.3.6.1.4.1.10418.17.2.5.3.1.84 integer read-write
noAction(1) = always returned in a GET. Does nothing if SET. reset(2) = when SET the reset command is sent to PDU. Enumeration: 'reset': 2, 'noAction': 1.
                       pmPowerMgmtPDUTablePowerFactorType 1.3.6.1.4.1.10418.17.2.5.3.1.85 integer read-only
Type of power values. Returns 0 if not supported. Enumeration: 'none-sensor': 0, 'estimated': 1, 'measured': 2.
                       pmPowerMgmtPDUTablePowerControl 1.3.6.1.4.1.10418.17.2.5.3.1.90 integer read-write
A set value of power*(2-4) will send command to PDU. noAction(1) = always returned in a GET. Does nothing if SET. powerOn(2) = when SET the power On command is sent to PDU. powerOff(3) = when SET the power Off command is sent to PDU. powerCycle(4)=when SET the power cycle command is sent to PDU. Returns 0 if not supported. Enumeration: 'powerOff': 3, 'powerOn': 2, 'powerCycle': 4, 'noAction': 1.
                       pmPowerMgmtPDUTableResetOCP 1.3.6.1.4.1.10418.17.2.5.3.1.91 integer read-write
A set value of power*(2) will send command to PDU. noAction(1) = always returned in a GET. Does nothing if SET. reset(2) = when SET the reset command is sent to PDU. Returns 0 if not supported. Enumeration: 'reset': 2, 'noAction': 1.
                       pmPowerMgmtPDUTableCurrentHighCritical 1.3.6.1.4.1.10418.17.2.5.3.1.100 integer32 read-write
outlet high critical (alarm) current threshold (A x 10). Set fails if value is lower that CurrentHighWarning. Returns 0 if not supported.
                       pmPowerMgmtPDUTableCurrentHighWarning 1.3.6.1.4.1.10418.17.2.5.3.1.101 integer32 read-write
outlet high warning current threshold (A x 10). Set fails if value is higher than CurrentHighCritical or lower than CurrentLowWarning. Returns 0 if not supported.
                       pmPowerMgmtPDUTableCurrentLowWarning 1.3.6.1.4.1.10418.17.2.5.3.1.102 integer32 read-write
outlet low warning current threshold (A x 10). Set fails if value is higher than CurrentHighWarning or lower than CurrentLowCritical. Returns 0 if not supported.
                       pmPowerMgmtPDUTableCurrentLowCritical 1.3.6.1.4.1.10418.17.2.5.3.1.103 integer32 read-write
outlet low critical current threshold (A x 10). Set fails if value is higher than CurrentLowWarning. Returns 0 if not supported.
                       pmPowerMgmtPDUTableEnergyValue 1.3.6.1.4.1.10418.17.2.5.3.1.105 integer32 read-only
pdu energy value (Wh). Returns 0 if not supported.
                       pmPowerMgmtPDUTableEnergyStartTime 1.3.6.1.4.1.10418.17.2.5.3.1.106 displaystring read-only
time at which energy calculation commenced (ISO8601 format). Returns N/A if not applicable.
                       pmPowerMgmtPDUTableEnergyReset 1.3.6.1.4.1.10418.17.2.5.3.1.107 integer read-write
noAction(1) = always returned in a GET. Does nothing if SET. reset(2) = when SET the reset command is sent to PDU. Enumeration: 'reset': 2, 'noAction': 1.
               pmPowerMgmtTotalNumberOfOutlets 1.3.6.1.4.1.10418.17.2.5.4 integer32 read-only
Number of outlets managed by the appliance.
               pmPowerMgmtOutletsTable 1.3.6.1.4.1.10418.17.2.5.5 no-access
This table contains the information about outlets.
                   pmPowerMgmtOutletsTableEntry 1.3.6.1.4.1.10418.17.2.5.5.1 no-access
each entry has the information about the outlet.
                       pmPowerMgmtOutletsTablePortNumber 1.3.6.1.4.1.10418.17.2.5.5.1.1 interfaceindex read-only
Serial Port number.
                       pmPowerMgmtOutletsTablePduNumber 1.3.6.1.4.1.10418.17.2.5.5.1.2 interfaceindex read-only
Index.
                       pmPowerMgmtOutletsTableNumber 1.3.6.1.4.1.10418.17.2.5.5.1.3 interfaceindex read-only
Number of the outlet in the PDU.
                       pmPowerMgmtOutletsTableName 1.3.6.1.4.1.10418.17.2.5.5.1.4 displaystring read-write
Name of the outlet.
                       pmPowerMgmtOutletsTableStatus 1.3.6.1.4.1.10418.17.2.5.5.1.5 integer read-only
Status of the outlet. Returns 0 if not supported. Enumeration: 'on': 2, 'offCycle': 5, 'off': 1, 'onLocked': 4, 'offLocked': 3, 'onPendingOff': 6, 'onFixed': 10, 'offShutdown': 11, 'notSet': 9, 'onPendingCycle': 8, 'offPendingOn': 7, 'tripped': 12.
                       pmPowerMgmtOutletsTablePowerControl 1.3.6.1.4.1.10418.17.2.5.5.1.6 integer read-write
A set value of power*(2-6) will send command to PDU. noAction(1) = always returned in a GET. Does nothing if SET. powerOn(2) = when SET the power On command is sent to PDU. powerOff(3) = when SET the power Off command is sent to PDU. powerCycle(4)=when SET the power cycle command is sent to PDU. powerLock(5)= when SET the power lock command is sent to PDU. powerUnlock(6)=when SET the power unlock command is sent to PDU. The powerLock and powerUnlock are valid only for Cyclades-PM PDUs Enumeration: 'powerCycle': 4, 'powerUnlock': 6, 'powerLock': 5, 'noAction': 1, 'powerOff': 3, 'powerOn': 2.
                       pmPowerMgmtOutletsTablePortName 1.3.6.1.4.1.10418.17.2.5.5.1.7 displaystring read-only
Serial Port Name where the PDU is connected.
                       pmPowerMgmtOutletsTablePduId 1.3.6.1.4.1.10418.17.2.5.5.1.8 displaystring read-only
PDU identification.
                       pmPowerMgmtOutletsTablePostOnDelay 1.3.6.1.4.1.10418.17.2.5.5.1.9 integer32 read-write
post on delay for the outlet (seconds x 10) Returns 0 if not supported.
                       pmPowerMgmtOutletsTablePostOffDelay 1.3.6.1.4.1.10418.17.2.5.5.1.10 integer32 read-write
post off delay for the outlet (seconds x 10) Returns 0 if not supported.
                       pmPowerMgmtOutletsTableAlarm 1.3.6.1.4.1.10418.17.2.5.5.1.45 integer read-only
Show the outlet alarm status. Returns 0 if not supported. Enumeration: 'high-critical': 4, 'normal': 1, 'hw-ocp': 3, 'high-warning': 5, 'low-warning': 6, 'blow-fuse': 2, 'low-critical': 7.
                       pmPowerMgmtOutletsTableCurrentValue 1.3.6.1.4.1.10418.17.2.5.5.1.50 integer32 read-only
Actual value of current in the outlet (A x 10). Returns 0 if not supported.
                       pmPowerMgmtOutletsTableCurrentMax 1.3.6.1.4.1.10418.17.2.5.5.1.51 integer32 read-only
Maximum value of current in the outlet (A x 10). Returns 0 if not supported.
                       pmPowerMgmtOutletsTableCurrentMin 1.3.6.1.4.1.10418.17.2.5.5.1.52 integer32 read-only
Minimum value of current in the outlet (A x 10). Returns 0 if not supported.
                       pmPowerMgmtOutletsTableCurrentAvg 1.3.6.1.4.1.10418.17.2.5.5.1.53 integer32 read-only
Average value of current in the outlet (A x 10). Returns 0 if not supported.
                       pmPowerMgmtOutletsTableCurrentReset 1.3.6.1.4.1.10418.17.2.5.5.1.54 integer read-write
noAction(1) = always returned in a GET. Does nothing if SET. reset(2) = when SET the reset command is sent to PDU. Enumeration: 'reset': 2, 'noAction': 1.
                       pmPowerMgmtOutletsTablePowerValue 1.3.6.1.4.1.10418.17.2.5.5.1.60 integer32 read-only
Actual value of power in the outlet (W x 10). Returns 0 if not supported.
                       pmPowerMgmtOutletsTablePowerMax 1.3.6.1.4.1.10418.17.2.5.5.1.61 integer32 read-only
Maximum value of power in the outlet (W x 10). Returns 0 if not supported.
                       pmPowerMgmtOutletsTablePowerMin 1.3.6.1.4.1.10418.17.2.5.5.1.62 integer32 read-only
Minimum value of power in the outlet (W x 10). Returns 0 if not supported.
                       pmPowerMgmtOutletsTablePowerAvg 1.3.6.1.4.1.10418.17.2.5.5.1.63 integer32 read-only
Average value of power in the outlet (W x 10). Returns 0 if not supported.
                       pmPowerMgmtOutletsTablePowerReset 1.3.6.1.4.1.10418.17.2.5.5.1.64 integer read-write
noAction(1) = always returned in a GET. Does nothing if SET. reset(2) = when SET the reset command is sent to PDU. Enumeration: 'reset': 2, 'noAction': 1.
                       pmPowerMgmtOutletsTablePowerType 1.3.6.1.4.1.10418.17.2.5.5.1.65 integer read-only
Type of power values. Returns 0 if not supported. Enumeration: 'none-sensor': 0, 'estimated': 1, 'measured': 2.
                       pmPowerMgmtOutletsTableVoltageValue 1.3.6.1.4.1.10418.17.2.5.5.1.70 integer32 read-only
Actual value of voltage in the outlet (V). Returns 0 if not supported.
                       pmPowerMgmtOutletsTableVoltageMax 1.3.6.1.4.1.10418.17.2.5.5.1.71 integer32 read-only
Maximum value of voltage in the outlet (V). Returns 0 if not supported.
                       pmPowerMgmtOutletsTableVoltageMin 1.3.6.1.4.1.10418.17.2.5.5.1.72 integer32 read-only
Minimum value of voltage in the outlet (V). Returns 0 if not supported.
                       pmPowerMgmtOutletsTableVoltageAvg 1.3.6.1.4.1.10418.17.2.5.5.1.73 integer32 read-only
Average value of voltage in the outlet (V). Returns 0 if not supported.
                       pmPowerMgmtOutletsTableVoltageReset 1.3.6.1.4.1.10418.17.2.5.5.1.74 integer read-write
noAction(1) = always returned in a GET. Does nothing if SET. reset(2) = when SET the reset command is sent to PDU. Enumeration: 'reset': 2, 'noAction': 1.
                       pmPowerMgmtOutletsTableVoltageType 1.3.6.1.4.1.10418.17.2.5.5.1.75 integer read-only
Type of voltage values. Returns 0 if not supported. Enumeration: 'none-sensor': 0, 'estimated': 1, 'measured': 2.
                       pmPowerMgmtOutletsTablePowerFactorValue 1.3.6.1.4.1.10418.17.2.5.5.1.80 integer32 read-only
Actual value of power factor in the outlet (Pf x 100). Returns 0 if not supported.
                       pmPowerMgmtOutletsTablePowerFactorMax 1.3.6.1.4.1.10418.17.2.5.5.1.81 integer32 read-only
Maximum value of power factor in the outlet (Pf x 100). Returns 0 if not supported.
                       pmPowerMgmtOutletsTablePowerFactorMin 1.3.6.1.4.1.10418.17.2.5.5.1.82 integer32 read-only
Minimum value of power factor in the outlet (Pf x 100). Returns 0 if not supported.
                       pmPowerMgmtOutletsTablePowerFactorAvg 1.3.6.1.4.1.10418.17.2.5.5.1.83 integer32 read-only
Average value of power factor in the outlet (Pf x 100). Returns 0 if not supported.
                       pmPowerMgmtOutletsTablePowerFactorReset 1.3.6.1.4.1.10418.17.2.5.5.1.84 integer read-write
noAction(1) = always returned in a GET. Does nothing if SET. reset(2) = when SET the reset command is sent to PDU. Enumeration: 'reset': 2, 'noAction': 1.
                       pmPowerMgmtOutletsTablePowerFactorType 1.3.6.1.4.1.10418.17.2.5.5.1.85 integer read-only
Type of power factor values. Returns 0 if not supported. Enumeration: 'none-sensor': 0, 'estimated': 1, 'measured': 2.
                       pmPowerMgmtOutletsTableCurrentHighCritical 1.3.6.1.4.1.10418.17.2.5.5.1.100 integer32 read-write
outlet high critical (alarm) current threshold (A x 10). Set fails if value is lower that CurrentHighWarning. Returns 0 if not supported.
                       pmPowerMgmtOutletsTableCurrentHighWarning 1.3.6.1.4.1.10418.17.2.5.5.1.101 integer32 read-write
outlet high warning current threshold (A x 10). Set fails if value is higher than CurrentHighCritical or lower than CurrentLowWarning. Returns 0 if not supported.
                       pmPowerMgmtOutletsTableCurrentLowWarning 1.3.6.1.4.1.10418.17.2.5.5.1.102 integer32 read-write
outlet low warning current threshold (A x 10). Set fails if value is higher than CurrentHighWarning or lower than CurrentLowCritical. Returns 0 if not supported.
                       pmPowerMgmtOutletsTableCurrentLowCritical 1.3.6.1.4.1.10418.17.2.5.5.1.103 integer32 read-write
outlet low critical current threshold (A x 10). Set fails if value is higher than CurrentLowWarning. Returns 0 if not supported.
                       pmPowerMgmtOutletsTableEnergyValue 1.3.6.1.4.1.10418.17.2.5.5.1.105 integer32 read-only
outlet energy value (Wh). Returns 0 if not supported.
                       pmPowerMgmtOutletsTableEnergyStartTime 1.3.6.1.4.1.10418.17.2.5.5.1.106 displaystring read-only
time at which energy calculation commenced (ISO8601 format). Returns N/A if not applicable.
                       pmPowerMgmtOutletsTableEnergyReset 1.3.6.1.4.1.10418.17.2.5.5.1.107 integer read-write
noAction(1) = always returned in a GET. Does nothing if SET. reset(2) = when SET the reset command is sent to PDU. Enumeration: 'reset': 2, 'noAction': 1.
               pmPowerMgmtNumberOfOutletGroup 1.3.6.1.4.1.10418.17.2.5.6 integer32 read-only
Number of configured group of outlets.
               pmPowerMgmtGroupTable 1.3.6.1.4.1.10418.17.2.5.7 no-access
This table contains the information about group of outlets.
                   pmPowerMgmtGroupTableEntry 1.3.6.1.4.1.10418.17.2.5.7.1 no-access
each entry has the information about group of outlets.
                       pmPowerMgmtGroupTableIndex 1.3.6.1.4.1.10418.17.2.5.7.1.1 interfaceindexorzero read-only
Index of the group.
                       pmPowerMgmtGroupTableName 1.3.6.1.4.1.10418.17.2.5.7.1.2 displaystring read-only
Name of the group of outlets.
                       pmPowerMgmtGroupTableStatus 1.3.6.1.4.1.10418.17.2.5.7.1.3 integer read-only
Status of the group of outlet. Enumeration: 'on': 2, 'off': 1.
                       pmPowerMgmtGroupTablePowerControl 1.3.6.1.4.1.10418.17.2.5.7.1.4 integer read-write
A set value of power*(2-4) will send command to PDU. noAction(1) = always returned in a GET. Does nothing if SET. powerOn(2) = when SET the power On command is sent to PDU. powerOff(3) = when SET the power Off command is sent to PDU. powerCycle(4)=when SET the power cycle command is sent to PDU. Enumeration: 'powerOff': 3, 'powerOn': 2, 'powerCycle': 4, 'noAction': 1.
               pmPowerMgmtTotalNumberOfPhases 1.3.6.1.4.1.10418.17.2.5.8 integer32 read-only
Number of phases managed by the appliance.
               pmPowerMgmtPhasesTable 1.3.6.1.4.1.10418.17.2.5.9 no-access
This table contains the information about phases.
                   pmPowerMgmtPhasesTableEntry 1.3.6.1.4.1.10418.17.2.5.9.1 no-access
each entry has the information about the phases.
                       pmPowerMgmtPhasesTablePortNumber 1.3.6.1.4.1.10418.17.2.5.9.1.1 interfaceindex read-only
Serial Port number.
                       pmPowerMgmtPhasesTablePduNumber 1.3.6.1.4.1.10418.17.2.5.9.1.2 interfaceindex read-only
Index.
                       pmPowerMgmtPhasesTableNumber 1.3.6.1.4.1.10418.17.2.5.9.1.3 interfaceindex read-only
Number of the phase in the PDU.
                       pmPowerMgmtPhasesTableName 1.3.6.1.4.1.10418.17.2.5.9.1.4 displaystring read-only
Name of the phase. Returns N/A if not applicable.
                       pmPowerMgmtPhasesTablePortName 1.3.6.1.4.1.10418.17.2.5.9.1.5 displaystring read-only
Serial Port Name where the PDU is connected.
                       pmPowerMgmtPhasesTablePduId 1.3.6.1.4.1.10418.17.2.5.9.1.6 displaystring read-only
PDU identification.
                       pmPowerMgmtPhasesTableAlarm 1.3.6.1.4.1.10418.17.2.5.9.1.45 integer read-only
Show the phase alarm status. Returns 0 if not supported. Enumeration: 'high-critical': 4, 'normal': 1, 'hw-ocp': 3, 'high-warning': 5, 'low-warning': 6, 'blow-fuse': 2, 'low-critical': 7.
                       pmPowerMgmtPhasesTableCurrentValue 1.3.6.1.4.1.10418.17.2.5.9.1.50 integer32 read-only
Actual value of current in the phase (A x 10). Returns 0 if not supported.
                       pmPowerMgmtPhasesTableCurrentMax 1.3.6.1.4.1.10418.17.2.5.9.1.51 integer32 read-only
Maximum value of current in the phase (A x 10). Returns 0 if not supported.
                       pmPowerMgmtPhasesTableCurrentMin 1.3.6.1.4.1.10418.17.2.5.9.1.52 integer32 read-only
Minimum value of current in the phase (A x 10). Returns 0 if not supported.
                       pmPowerMgmtPhasesTableCurrentAvg 1.3.6.1.4.1.10418.17.2.5.9.1.53 integer32 read-only
Average value of current in the phase (A x 10). Returns 0 if not supported.
                       pmPowerMgmtPhasesTableCurrentReset 1.3.6.1.4.1.10418.17.2.5.9.1.54 integer read-write
noAction(1) = always returned in a GET. Does nothing if SET. reset(2) = when SET the reset command is sent to PDU. Enumeration: 'reset': 2, 'noAction': 1.
                       pmPowerMgmtPhasesTablePowerValue 1.3.6.1.4.1.10418.17.2.5.9.1.60 integer32 read-only
Actual value of power in the phase (W x 10). Returns 0 if not supported.
                       pmPowerMgmtPhasesTablePowerMax 1.3.6.1.4.1.10418.17.2.5.9.1.61 integer32 read-only
Maximum value of power in the phase (W x 10). Returns 0 if not supported.
                       pmPowerMgmtPhasesTablePowerMin 1.3.6.1.4.1.10418.17.2.5.9.1.62 integer32 read-only
Minimum value of power in the phase (W x 10). Returns 0 if not supported.
                       pmPowerMgmtPhasesTablePowerAvg 1.3.6.1.4.1.10418.17.2.5.9.1.63 integer32 read-only
Average value of power in the phase (W x 10). Returns 0 if not supported.
                       pmPowerMgmtPhasesTablePowerReset 1.3.6.1.4.1.10418.17.2.5.9.1.64 integer read-write
noAction(1) = always returned in a GET. Does nothing if SET. reset(2) = when SET the reset command is sent to PDU. Enumeration: 'reset': 2, 'noAction': 1.
                       pmPowerMgmtPhasesTablePowerType 1.3.6.1.4.1.10418.17.2.5.9.1.65 integer read-only
Type of power values. Returns 0 if not supported. Enumeration: 'none-sensor': 0, 'estimated': 1, 'measured': 2.
                       pmPowerMgmtPhasesTableVoltageValue 1.3.6.1.4.1.10418.17.2.5.9.1.70 integer32 read-only
Actual value of voltage in the phase (V). Returns 0 if not supported.
                       pmPowerMgmtPhasesTableVoltageMax 1.3.6.1.4.1.10418.17.2.5.9.1.71 integer32 read-only
Maximum value of voltage in the phase (V). Returns 0 if not supported.
                       pmPowerMgmtPhasesTableVoltageMin 1.3.6.1.4.1.10418.17.2.5.9.1.72 integer32 read-only
Minimum value of voltage in the phase (V). Returns 0 if not supported.
                       pmPowerMgmtPhasesTableVoltageAvg 1.3.6.1.4.1.10418.17.2.5.9.1.73 integer32 read-only
Average value of voltage in the phase (V). Returns 0 if not supported.
                       pmPowerMgmtPhasesTableVoltageReset 1.3.6.1.4.1.10418.17.2.5.9.1.74 integer read-write
noAction(1) = always returned in a GET. Does nothing if SET. reset(2) = when SET the reset command is sent to PDU. Enumeration: 'reset': 2, 'noAction': 1.
                       pmPowerMgmtPhasesTableVoltageType 1.3.6.1.4.1.10418.17.2.5.9.1.75 integer read-only
Type of voltage values. Returns 0 if not supported. Enumeration: 'none-sensor': 0, 'estimated': 1, 'measured': 2.
                       pmPowerMgmtPhasesTablePowerFactorValue 1.3.6.1.4.1.10418.17.2.5.9.1.80 integer32 read-only
Actual value of power factor in the phase (Pf x 100). Returns 0 if not supported.
                       pmPowerMgmtPhasesTablePowerFactorMax 1.3.6.1.4.1.10418.17.2.5.9.1.81 integer32 read-only
Maximum value of power factor in the phase (Pf x 100). Returns 0 if not supported.
                       pmPowerMgmtPhasesTablePowerFactorMin 1.3.6.1.4.1.10418.17.2.5.9.1.82 integer32 read-only
Minimum value of power factor in the phase (Pf x 100). Returns 0 if not supported.
                       pmPowerMgmtPhasesTablePowerFactorAvg 1.3.6.1.4.1.10418.17.2.5.9.1.83 integer32 read-only
Average value of power factor in the phase (Pf x 100). Returns 0 if not supported.
                       pmPowerMgmtPhasesTablePowerFactorReset 1.3.6.1.4.1.10418.17.2.5.9.1.84 integer read-write
noAction(1) = always returned in a GET. Does nothing if SET. reset(2) = when SET the reset command is sent to PDU. Enumeration: 'reset': 2, 'noAction': 1.
                       pmPowerMgmtPhasesTablePowerFactorType 1.3.6.1.4.1.10418.17.2.5.9.1.85 integer read-only
Type of power factor values. Returns 0 if not supported. Enumeration: 'none-sensor': 0, 'estimated': 1, 'measured': 2.
                       pmPowerMgmtPhasesTableCurrentHighCritical 1.3.6.1.4.1.10418.17.2.5.9.1.100 integer32 read-write
phase high critical (alarm) current threshold (A x 10). Set fails if value is lower that CurrentHighWarning. Returns 0 if not supported.
                       pmPowerMgmtPhasesTableCurrentHighWarning 1.3.6.1.4.1.10418.17.2.5.9.1.101 integer32 read-write
phase high warning current threshold (A x 10). Set fails if value is higher than CurrentHighCritical or lower than CurrentLowWarning. Returns 0 if not supported.
                       pmPowerMgmtPhasesTableCurrentLowWarning 1.3.6.1.4.1.10418.17.2.5.9.1.102 integer32 read-write
phase low warning current threshold (A x 10). Set fails if value is higher than CurrentHighWarning or lower than CurrentLowCritical. Returns 0 if not supported.
                       pmPowerMgmtPhasesTableCurrentLowCritical 1.3.6.1.4.1.10418.17.2.5.9.1.103 integer32 read-write
phase low critical current threshold (A x 10). Set fails if value is higher than CurrentLowWarning. Returns 0 if not supported.
               pmPowerMgmtTotalNumberOfBanks 1.3.6.1.4.1.10418.17.2.5.10 integer32 read-only
Number of banks managed by the appliance.
               pmPowerMgmtBanksTable 1.3.6.1.4.1.10418.17.2.5.11 no-access
This table contains the information about banks.
                     pmPowerMgmtBanksTableEntry 1.3.6.1.4.1.10418.17.2.5.11.1 no-access
each entry has the information about the banks.
                         pmPowerMgmtBanksTablePortNumber 1.3.6.1.4.1.10418.17.2.5.11.1.1 interfaceindex read-only
Serial Port number.
                         pmPowerMgmtBanksTablePduNumber 1.3.6.1.4.1.10418.17.2.5.11.1.2 interfaceindex read-only
Index.
                         pmPowerMgmtBanksTableNumber 1.3.6.1.4.1.10418.17.2.5.11.1.3 interfaceindex read-only
Number of the bank in the PDU.
                         pmPowerMgmtBanksTableName 1.3.6.1.4.1.10418.17.2.5.11.1.4 displaystring read-only
Name of the bank.
                         pmPowerMgmtBanksTablePortName 1.3.6.1.4.1.10418.17.2.5.11.1.5 displaystring read-only
Serial Port Name where the PDU is connected.
                         pmPowerMgmtBanksTablePduId 1.3.6.1.4.1.10418.17.2.5.11.1.6 displaystring read-only
PDU identification.
                         pmPowerMgmtBanksTableAlarm 1.3.6.1.4.1.10418.17.2.5.11.1.45 integer read-only
Show the bank alarm status. Returns 0 if not supported. Enumeration: 'high-critical': 4, 'normal': 1, 'hw-ocp': 3, 'high-warning': 5, 'low-warning': 6, 'blow-fuse': 2, 'low-critical': 7.
                         pmPowerMgmtBanksTableCurrentValue 1.3.6.1.4.1.10418.17.2.5.11.1.50 integer32 read-only
Actual value of current in the bank (A x 10). Returns 0 if not supported.
                         pmPowerMgmtBanksTableCurrentMax 1.3.6.1.4.1.10418.17.2.5.11.1.51 integer32 read-only
Maximum value of current in the bank (A x 10). Returns 0 if not supported.
                         pmPowerMgmtBanksTableCurrentMin 1.3.6.1.4.1.10418.17.2.5.11.1.52 integer32 read-only
Minimum value of current in the bank (A x 10). Returns 0 if not supported.
                         pmPowerMgmtBanksTableCurrentAvg 1.3.6.1.4.1.10418.17.2.5.11.1.53 integer32 read-only
Average value of current in the bank (A x 10). Returns 0 if not supported.
                         pmPowerMgmtBanksTableCurrentReset 1.3.6.1.4.1.10418.17.2.5.11.1.54 integer read-write
noAction(1) = always returned in a GET. Does nothing if SET. reset(2) = when SET the reset command is sent to PDU. Enumeration: 'reset': 2, 'noAction': 1.
                         pmPowerMgmtBanksTablePowerValue 1.3.6.1.4.1.10418.17.2.5.11.1.60 integer32 read-only
Actual value of power in the bank (W x 10). Returns 0 if not supported.
                         pmPowerMgmtBanksTablePowerMax 1.3.6.1.4.1.10418.17.2.5.11.1.61 integer32 read-only
Maximum value of power in the bank (W x 10). Returns 0 if not supported.
                         pmPowerMgmtBanksTablePowerMin 1.3.6.1.4.1.10418.17.2.5.11.1.62 integer32 read-only
Minimum value of power in the bank (W x 10). Returns 0 if not supported.
                         pmPowerMgmtBanksTablePowerAvg 1.3.6.1.4.1.10418.17.2.5.11.1.63 integer32 read-only
Average value of power in the bank (W x 10). Returns 0 if not supported.
                         pmPowerMgmtBanksTablePowerReset 1.3.6.1.4.1.10418.17.2.5.11.1.64 integer read-write
noAction(1) = always returned in a GET. Does nothing if SET. reset(2) = when SET the reset command is sent to PDU. Enumeration: 'reset': 2, 'noAction': 1.
                         pmPowerMgmtBanksTablePowerType 1.3.6.1.4.1.10418.17.2.5.11.1.65 integer read-only
Type of power values. Returns 0 if not supported. Enumeration: 'none-sensor': 0, 'estimated': 1, 'measured': 2.
                         pmPowerMgmtBanksTableVoltageValue 1.3.6.1.4.1.10418.17.2.5.11.1.70 integer32 read-only
Actual value of voltage in the bank (V). Returns 0 if not supported.
                         pmPowerMgmtBanksTableVoltageMax 1.3.6.1.4.1.10418.17.2.5.11.1.71 integer32 read-only
Maximum value of voltage in the bank (V). Returns 0 if not supported.
                         pmPowerMgmtBanksTableVoltageMin 1.3.6.1.4.1.10418.17.2.5.11.1.72 integer32 read-only
Minimum value of voltage in the bank (V). Returns 0 if not supported.
                         pmPowerMgmtBanksTableVoltageAvg 1.3.6.1.4.1.10418.17.2.5.11.1.73 integer32 read-only
Average value of voltage in the bank (V). Returns 0 if not supported.
                         pmPowerMgmtBanksTableVoltageReset 1.3.6.1.4.1.10418.17.2.5.11.1.74 integer read-write
noAction(1) = always returned in a GET. Does nothing if SET. reset(2) = when SET the reset command is sent to PDU. Enumeration: 'reset': 2, 'noAction': 1.
                         pmPowerMgmtBanksTableVoltageType 1.3.6.1.4.1.10418.17.2.5.11.1.75 integer read-only
Type of voltage values. Returns 0 if not supported. Enumeration: 'none-sensor': 0, 'estimated': 1, 'measured': 2.
                         pmPowerMgmtBanksTablePowerFactorValue 1.3.6.1.4.1.10418.17.2.5.11.1.80 integer32 read-only
Actual value of power factor in the bank (Pf x 100). Returns 0 if not supported.
                         pmPowerMgmtBanksTablePowerFactorMax 1.3.6.1.4.1.10418.17.2.5.11.1.81 integer32 read-only
Maximum value of power factor in the bank (Pf x 100). Returns 0 if not supported.
                         pmPowerMgmtBanksTablePowerFactorMin 1.3.6.1.4.1.10418.17.2.5.11.1.82 integer32 read-only
Minimum value of power factor in the bank (Pf x 100). Returns 0 if not supported.
                         pmPowerMgmtBanksTablePowerFactorAvg 1.3.6.1.4.1.10418.17.2.5.11.1.83 integer32 read-only
Average value of power factor in the bank (Pf x 100). Returns 0 if not supported.
                         pmPowerMgmtBanksTablePowerFactorReset 1.3.6.1.4.1.10418.17.2.5.11.1.84 integer read-write
noAction(1) = always returned in a GET. Does nothing if SET. reset(2) = when SET the reset command is sent to PDU. Enumeration: 'reset': 2, 'noAction': 1.
                         pmPowerMgmtBanksTablePowerFactorType 1.3.6.1.4.1.10418.17.2.5.11.1.85 integer read-only
Type of power factor values. Returns 0 if not supported. Enumeration: 'none-sensor': 0, 'estimated': 1, 'measured': 2.
                         pmPowerMgmtBanksTableCurrentHighCritical 1.3.6.1.4.1.10418.17.2.5.11.1.100 integer32 read-write
bank high critical (alarm) current threshold (A x 10). Set fails if value is lower that CurrentHighWarning. Returns 0 if not supported.
                         pmPowerMgmtBanksTableCurrentHighWarning 1.3.6.1.4.1.10418.17.2.5.11.1.101 integer32 read-write
bank high warning current threshold (A x 10). Set fails if value is higher than CurrentHighCritical or lower than CurrentLowWarning. Returns 0 if not supported.
                         pmPowerMgmtBanksTableCurrentLowWarning 1.3.6.1.4.1.10418.17.2.5.11.1.102 integer32 read-write
bank low warning current threshold (A x 10). Set fails if value is higher than CurrentHighWarning or lower than CurrentLowCritical. Returns 0 if not supported.
                         pmPowerMgmtBanksTableCurrentLowCritical 1.3.6.1.4.1.10418.17.2.5.11.1.103 integer32 read-write
bank low critical current threshold (A x 10). Set fails if value is higher than CurrentLowWarning. Returns 0 if not supported.
                         pmPowerMgmtBanksTableEnergyValue 1.3.6.1.4.1.10418.17.2.5.11.1.105 integer32 read-only
bank energy value (Wh). Returns 0 if not supported.
                         pmPowerMgmtBanksTableEnergyStartTime 1.3.6.1.4.1.10418.17.2.5.11.1.106 displaystring read-only
time at which energy calculation commenced (ISO8601 format). Returns N/A if not applicable.
                         pmPowerMgmtBanksTableEnergyReset 1.3.6.1.4.1.10418.17.2.5.11.1.107 integer read-write
noAction(1) = always returned in a GET. Does nothing if SET. reset(2) = when SET the reset command is sent to PDU. Enumeration: 'reset': 2, 'noAction': 1.
               pmPowerMgmtTotalNumberOfSensors 1.3.6.1.4.1.10418.17.2.5.12 integer32 read-only
Number of Sensors managed by the appliance.
               pmPowerMgmtSensorsTable 1.3.6.1.4.1.10418.17.2.5.13 no-access
This table contains the information about sensors.
                     pmPowerMgmtSensorsTableEntry 1.3.6.1.4.1.10418.17.2.5.13.1 no-access
each entry has the information about the sensors.
                         pmPowerMgmtSensorsTablePortNumber 1.3.6.1.4.1.10418.17.2.5.13.1.1 interfaceindex read-only
Serial Port number.
                         pmPowerMgmtSensorsTablePduNumber 1.3.6.1.4.1.10418.17.2.5.13.1.2 interfaceindex read-only
Index.
                         pmPowerMgmtSensorsTableNumber 1.3.6.1.4.1.10418.17.2.5.13.1.3 interfaceindex read-only
Number of the sensor in the PDU.
                         pmPowerMgmtSensorsTableName 1.3.6.1.4.1.10418.17.2.5.13.1.4 displaystring read-write
Name of the sensor.
                         pmPowerMgmtSensorsTablePortName 1.3.6.1.4.1.10418.17.2.5.13.1.5 displaystring read-only
Serial Port Name where the PDU is connected.
                         pmPowerMgmtSensorsTablePduId 1.3.6.1.4.1.10418.17.2.5.13.1.6 displaystring read-only
PDU identification.
                         pmPowerMgmtSensorsTableType 1.3.6.1.4.1.10418.17.2.5.13.1.7 integer read-only
The type of environmental monitor. Returns 0 if not supported. Enumeration: 'temperature': 2, 'dry-concact': 6, 'water-level': 7, 'unknown': 10, 'humidity': 3, 'motion': 8, 'temp-internal': 1, 'smoke': 5, 'unplugged': 9, 'air-flow': 4.
                         pmPowerMgmtSensorsTableStatus 1.3.6.1.4.1.10418.17.2.5.13.1.8 integer read-only
Status of digital sensors: Dry-Contact, Water level, Smoke sensor, Motion sensor. Returns 0 if not supported. Enumeration: 'normal': 1, 'triggered': 2, 'opened': 4, 'closed': 5, 'not-applicable': 3.
                         pmPowerMgmtSensorsTableValue 1.3.6.1.4.1.10418.17.2.5.13.1.20 displaystring read-only
Actual value of the sensor. Returns N/A if not applicable.
                         pmPowerMgmtSensorsTableValueMax 1.3.6.1.4.1.10418.17.2.5.13.1.21 displaystring read-only
Maximum value of the sensor. Returns N/A if not applicable.
                         pmPowerMgmtSensorsTableValueMin 1.3.6.1.4.1.10418.17.2.5.13.1.22 displaystring read-only
Minimum value of the sensor. Returns N/A if not applicable.
                         pmPowerMgmtSensorsTableValueAvg 1.3.6.1.4.1.10418.17.2.5.13.1.23 displaystring read-only
Average value of the sensor. Returns N/A if not applicable.
                         pmPowerMgmtSensorsTableValueInt 1.3.6.1.4.1.10418.17.2.5.13.1.25 integer32 read-only
Actual value of the sensor. Returns 0 if not supported.
                         pmPowerMgmtSensorsTableValueMaxInt 1.3.6.1.4.1.10418.17.2.5.13.1.26 integer32 read-only
Maximum value of the sensor. Returns 0 if not supported.
                         pmPowerMgmtSensorsTableValueMinInt 1.3.6.1.4.1.10418.17.2.5.13.1.27 integer32 read-only
Minimum value of the sensor. Returns 0 if not supported.
                         pmPowerMgmtSensorsTableValueAvgInt 1.3.6.1.4.1.10418.17.2.5.13.1.28 integer32 read-only
Average value of the sensor. Returns 0 if not supported.
                         pmPowerMgmtSensorsTableValueReset 1.3.6.1.4.1.10418.17.2.5.13.1.30 integer read-write
noAction(1) = always returned in a GET. Does nothing if SET. reset(2) = when SET the reset command is sent to sensor. Enumeration: 'reset': 2, 'noAction': 1.
                         pmPowerMgmtSensorsTableHighCritical 1.3.6.1.4.1.10418.17.2.5.13.1.40 integer32 read-write
sensor high critical (alarm) threshold (unit x 10) - use unit as returned by pmPowerMgmtSensorsTableUnit. Set fails if value is lower that CurrentHighWarning. Returns 0 if not supported.
                         pmPowerMgmtSensorsTableHighWarning 1.3.6.1.4.1.10418.17.2.5.13.1.41 integer32 read-write
sensor high warning threshold (unit x 10) - use unit as returned by pmPowerMgmtSensorsTableUnit. Set fails if value is higher than HighCritical or lower than LowWarning. Returns 0 if not supported.
                         pmPowerMgmtSensorsTableLowWarning 1.3.6.1.4.1.10418.17.2.5.13.1.42 integer32 read-write
sensor low warning threshold (unit x 10) - use unit as returned by pmPowerMgmtSensorsTableUnit. Set fails if value is higher than HighWarning or lower than LowCritical. Returns 0 if not supported.
                         pmPowerMgmtSensorsTableLowCritical 1.3.6.1.4.1.10418.17.2.5.13.1.43 integer32 read-write
sensor low critical threshold (unit x 10) - use unit as returned by pmPowerMgmtSensorsTableUnit. Set fails if value is higher than LowWarning. Returns 0 if not supported.
                         pmPowerMgmtSensorsTableUnit 1.3.6.1.4.1.10418.17.2.5.13.1.45 integer read-write
sensor unit. Returns 0 if not supported. Enumeration: 'fahrenheit': 2, 'af': 5, 'celsius': 3, 'percent': 4, 'undefined': 1.
                         pmPowerMgmtSensorsTableHighCriticalC 1.3.6.1.4.1.10418.17.2.5.13.1.50 integer32 read-only
sensor high critical (alarm) threshold (Celcius x 10). to SET: use pmPowerMgmtSensorsTableHighCritical in proper units (pmPowerMgmtSensorsTableUnit). Returns 0 if not supported.
                         pmPowerMgmtSensorsTableHighWarningC 1.3.6.1.4.1.10418.17.2.5.13.1.51 integer32 read-only
sensor high warning threshold (Celcius x 10). to SET: use pmPowerMgmtSensorsTableHighWarning in proper units (pmPowerMgmtSensorsTableUnit). Returns 0 if not supported.
                         pmPowerMgmtSensorsTableLowWarningC 1.3.6.1.4.1.10418.17.2.5.13.1.52 integer32 read-only
sensor low warning threshold (Celcius x 10). to SET: use pmPowerMgmtSensorsTableLowWarning in proper units (pmPowerMgmtSensorsTableUnit). Returns 0 if not supported.
                         pmPowerMgmtSensorsTableLowCriticalC 1.3.6.1.4.1.10418.17.2.5.13.1.53 integer32 read-only
sensor low critical threshold (Celcius x 10). to SET: use pmPowerMgmtSensorsTableLowCritical in proper units (pmPowerMgmtSensorsTableUnit). Returns 0 if not supported.
                         pmPowerMgmtSensorsTableHighCriticalF 1.3.6.1.4.1.10418.17.2.5.13.1.60 integer32 read-only
sensor high critical (alarm) threshold (Fahrenheit x 10). to SET: use pmPowerMgmtSensorsTableHighCritical in proper units (pmPowerMgmtSensorsTableUnit). Returns 0 if not supported.
                         pmPowerMgmtSensorsTableHighWarningF 1.3.6.1.4.1.10418.17.2.5.13.1.61 integer32 read-only
sensor high warning threshold (Fahrenheit x 10). to SET: use pmPowerMgmtSensorsTableHighWarning in proper units (pmPowerMgmtSensorsTableUnit). Returns 0 if not supported.
                         pmPowerMgmtSensorsTableLowWarningF 1.3.6.1.4.1.10418.17.2.5.13.1.62 integer32 read-only
sensor low warning threshold (Fahrenheit x 10). to SET: use pmPowerMgmtSensorsTableLowWarning in proper units (pmPowerMgmtSensorsTableUnit). Returns 0 if not supported.
                         pmPowerMgmtSensorsTableLowCriticalF 1.3.6.1.4.1.10418.17.2.5.13.1.63 integer32 read-only
sensor low critical threshold (Fahrenheit x 10). to SET: use pmPowerMgmtSensorsTableLowCritical in proper units (pmPowerMgmtSensorsTableUnit). Returns 0 if not supported.
           pmTrapObject 1.3.6.1.4.1.10418.17.2.6