PET-EVENTS: View SNMP OID List / Download MIB

VENDOR: WIRED FOR MANAGEMENT


 Home MIB: PET-EVENTS
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 wiredformgmt 1.3.6.1.4.1.3183
           pet 1.3.6.1.4.1.3183.1
               petEvts 1.3.6.1.4.1.3183.1.1
                     petTrapUnderTemperatureWarning 1.3.6.1.4.1.3183.1.10.65792
Under-Temperature Warning (Lower non-critical, going low)
                     petTrapUnderTemperatureCritical 1.3.6.1.4.1.3183.1.10.65794
Critical Under-Temperature Problem (Lower Critical - going low)
                     petTrapOverTemperatureWarning 1.3.6.1.4.1.3183.1.10.65799
Over-Temperature Warning (Upper non-critical, going high)
                     petTrapOverTemperatureCritical 1.3.6.1.4.1.3183.1.10.65801
Critical Over-Temperature Problem (Upper Critical - going high)
                     petTrapGenericCriticalTemperature 1.3.6.1.4.1.3183.1.10.67330
Generic Critical Temperature Problem (Transition to Critical from less severe)
                     petTrapGenericTemperatureWarning 1.3.6.1.4.1.3183.1.10.67331
Generic Temperature Warning (Transition to Warning from less severe)
                     petTrapUnderAnalogVoltageCritical 1.3.6.1.4.1.3183.1.10.131330
Critical Under-Voltage Problem (Lower Critical - going low)
                     petTrapOverAnalogVoltageCritical 1.3.6.1.4.1.3183.1.10.131337
Critical Over-Voltage Problem (Upper Critical - going high)
                     petTrapGenericCriticalDiscreteVoltage2 1.3.6.1.4.1.3183.1.10.132866
Generic Critical Voltage Problem (Transition to Critical from less severe)
                     petTrapGenericDiscreteVoltageWarning 1.3.6.1.4.1.3183.1.10.132867
Generic Voltage Warning (Transition to Non-Critical from less severe)
                     petTrapFanSpeedWarning 1.3.6.1.4.1.3183.1.10.262400
Fan speed warning (Fan speed below expected speed. Cooling still adequate)
                     petTrapFanSpeedproblem 1.3.6.1.4.1.3183.1.10.262402
Fan Speed Problem (speed too low to meet chassis cooling specs)
                     petTrapGenericFanWarning 1.3.6.1.4.1.3183.1.10.263169
Generic Predictive Fan failure (predictive failure asserted)
                     petTrapGenericCriticalFan 1.3.6.1.4.1.3183.1.10.263938
Generic Critical Fan failure (Transition to Critical from less severe)
                     petTrapChassisIntrusion 1.3.6.1.4.1.3183.1.10.356096
Chassis Intrusion - Physical Security Violation
                     petTrapProcessorInternalError 1.3.6.1.4.1.3183.1.10.487168
Processor Internal Error
                     petTrapProcessorThermalTrip 1.3.6.1.4.1.3183.1.10.487169
Processor Thermal Trip (Over Temperature Shutdown)
                     petTrapProcessorBistError 1.3.6.1.4.1.3183.1.10.487170
Processor Fault Resilient Booting (FRB) 1 / BIST (Built In Self Test) Failure
                     petTrapProcessorFRB2Failure 1.3.6.1.4.1.3183.1.10.487171
Processor Fault Resilient Booting (FRB) 2 / Hang in Power On Self Test (POST) Failure
                     petTrapProcessorFRB3Failure 1.3.6.1.4.1.3183.1.10.487172
Processor Fault Resilient Booting (FRB) 3 / Processor Setup / Initialization Failure
                     petTrapPowerSupplyFailureDetected 1.3.6.1.4.1.3183.1.10.552705
Power supply Failure detected
                     petTrapPowerSupplyWarning 1.3.6.1.4.1.3183.1.10.552706
Power supply Warning
                     petTrapMemoryUncorrectableECC 1.3.6.1.4.1.3183.1.10.814849
Uncorrectable ECC or other uncorrectable memory error
                     petTrapBIOSPOSTCodeError 1.3.6.1.4.1.3183.1.10.1011456
System Firmware Progress: BIOS POST code error
                     petTrapOEMSystemBootEvent 1.3.6.1.4.1.3183.1.10.1208065
OEM System Boot Event
                     petTrapCriticalInterruptBusTimeout 1.3.6.1.4.1.3183.1.10.1273601
Critical Interrupt, Bus Timeout error
                     petTrapCriticalInterruptIOChannelNMI 1.3.6.1.4.1.3183.1.10.1273602
Critical Interrupt, IO Channel check NMI error
                     petTrapCriticalInterruptSoftwareNMI 1.3.6.1.4.1.3183.1.10.1273603
Critical Interrupt, software NMI error
                     petTrapCriticalInterruptPCIPERR 1.3.6.1.4.1.3183.1.10.1273604
Critical Interrupt, PCI PERR parity error
                     petTrapCriticalInterruptPCISERR 1.3.6.1.4.1.3183.1.10.1273605
Critical Interrupt, PCI SERR parity error
                     petTrapCriticalInterruptBusUncorrect 1.3.6.1.4.1.3183.1.10.1273608
Critical Interrupt, Bus Uncorrectable error
                     petTrapCriticalInterruptFatalNMI 1.3.6.1.4.1.3183.1.10.1273609
Critical Interrupt, Fatal NMI error
                     petTrapWatchdogReset 1.3.6.1.4.1.3183.1.10.2322177
Watchdog Reset
                     petTrapWatchdogPowerDown 1.3.6.1.4.1.3183.1.10.2322178
Watchdog Power Down
                     petTrapWatchdogPowerCycle 1.3.6.1.4.1.3183.1.10.2322179
Watchdog Power Cycle