PANDATEL-FOBUS-MODEM-MIB: View SNMP OID List / Download MIB

VENDOR: PAN DACOM TELEKOMMUNIKATIONS


 Home MIB: PANDATEL-FOBUS-MODEM-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 fobus 1.3.6.1.4.1.760.1.1.2.1.10.501
         fobusModemTable 1.3.6.1.4.1.760.1.1.2.1.10.501.1 no-access
This table contains information about all FOBUS units in all racks.
             fobusTableEntry 1.3.6.1.4.1.760.1.1.2.1.10.501.1.1 no-access
The index of the table.
                 mdmRack 1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.1 integer read-only
The index of the rack where the unit is installed.
                 mdmModem 1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.2 integer read-only
This entry displays the slot number where the corresponding unit is installed in the rack.
                 mdmPosition 1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.3 integer read-only
This entry displays the location of the corresponding unit: 'local' or 'remote'. The unit which is plugged into a managed rack is 'local', the counterpart is 'remote'. Enumeration: 'remote': 2, 'local': 1.
                 mdmModemName 1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.5 displaystring read-only
The verbal name of this unit.
                 mdmBackupStatus 1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.11 integer read-only
The backup status of the unit. The available values depend on the generation of the unit. Enumeration: 'available': 5, 'not-available': 4, 'disable': 6, 'inactive': 2, 'active': 3, 'other': 1.
                 mdmActiveLink 1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.12 integer read-only
This entry displays the line port used for data transmission. Enumeration: 'line-port-2': 2, 'line-port-3': 3, 'disable': 90.
                 mdmOperationMode 1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.66 integer read-write
This entry defines if data is transmitted via port 2 or port 3: 'forced-port2', 'forced-port3', 'automatic'. Enumeration: 'automatic': 5, 'other': 1, 'forced-port3': 4, 'forced-port2': 3.
                 mdmAlarmConditionPort1 1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.110 integer read-write
The alarm trigger mode at port 1: 'disable', i.e. no alarm is triggered, or 'link-signal', i.e. an alarm is triggered if the link is down. Enumeration: 'other': 1, 'link-signal': 3, 'disable': 2.
                 mdmAlarmConditionPort2 1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.111 integer read-write
The alarm trigger mode at port 2: 'disable', i.e. no alarm is triggered, 'no-link-signal', i.e. an alarm is triggered if the link is down, 'laser-fail', i.e. an alarm is triggered if the laser diode is defective, or 'no-link-signal-or-laser-fail', i.e. the link is down or the laser diode is defective. Enumeration: 'no-link-signal': 3, 'no-link-signal-or-laser-fail': 5, 'other': 1, 'laser-fail': 4, 'disable': 2.
                 mdmAlarmConditionPort3 1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.112 integer read-write
The alarm trigger mode at port 3: 'disable', i.e. no alarm is triggered, 'no-link-signal', i.e. an alarm is triggered if the link is down, 'laser-fail', i.e. an alarm is triggered if the laser diode is defective, or 'no-link-signal-or-laser-fail', i.e. the link is down or the laser diode is defective. Enumeration: 'no-link-signal': 3, 'no-link-signal-or-laser-fail': 5, 'other': 1, 'laser-fail': 4, 'disable': 2.
                 mdmTXLaserStatusPort2 1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.121 integer read-only
This entry indicates if the laser diode at port 2 is transmitting data ('enable') or not ('disable'). Enumeration: 'enable': 3, 'other': 1, 'disable': 2.
                 mdmTXLaserStatusPort3 1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.122 integer read-only
This entry indicates if the laser diode at port 3 is transmitting data ('enable') or not ('disable'). Enumeration: 'enable': 3, 'other': 1, 'disable': 2.
                 fobus_modem 1.3.6.1.4.1.760.1.1.2.1.10.10000.2.501