OTN-MIB: View SNMP OID List / Download MIB

VENDOR: INTERNET-STANDARD


 Home MIB: OTN-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 optIfMibModule 1.3.6.1.2.1.10.1
The draft MIB module to describe OTN interfaces objects.
     optIfObjects 1.3.6.1.2.1.10.1.1
         optIfPerfMon 1.3.6.1.2.1.10.1.1.1
             optIfPerfMonCurrentTimeElapsed 1.3.6.1.2.1.10.1.1.1.1
Number of seconds elapsed in the current 15 minute performance monitoring interval.
             optIfPerfMonCurDayTimeElapsed 1.3.6.1.2.1.10.1.1.1.2
Number of seconds elapsed in the current calendar day performance monitoring period.
             optIfPerfMonIntervalTable 1.3.6.1.2.1.10.1.1.1.3
A table of 15 minute performance monitoring interval information.
                 optIfPerfMonIntervalEntry 1.3.6.1.2.1.10.1.1.1.3.1
A conceptual row that contains 15 minute performance monitoring interval information of an interface.
                     optIfPerfMonIntervalNumIntervals 1.3.6.1.2.1.10.1.1.1.3.1.1
The number of 15 minute intervals for which performance monitoring data is available. The number is the same for all the associated sub layers of the interface. An optical interface must be capable of supporting at least n intervals, where n is defined as follows: The minimum value of n is 4. The default of n is 32. The maximum value of n is 96. The value of this object will be n unless performance monitoring was (re-)started for the interface within the last (n*15) minutes, in which case the value will be the number of complete 15 minute intervals since measurement was (re-)started.
                     optIfPerfMonIntervalNumInvalidIntervals 1.3.6.1.2.1.10.1.1.1.3.1.2
The number of intervals in the range from 0 to optIfPerfMonIntervalNumIntervals for which no performance monitoring data is available and/or the data is invalid.
         optIfOTSn 1.3.6.1.2.1.10.1.1.2
             optIfOTSnConfigTable 1.3.6.1.2.1.10.1.1.2.1
A table of OTSn configuration information.
                 optIfOTSnConfigEntry 1.3.6.1.2.1.10.1.1.2.1.1
A conceptual row that contains OTSn configuration information of an interface.
                     optIfOTSnTraceIdentifierTransmitted 1.3.6.1.2.1.10.1.1.2.1.1.1
The trace identifier transmitted.
                     optIfOChSinkAdaptActive 1.3.6.1.2.1.10.1.1.2.1.1.1
Indicates whether the sink adaptation function is activated or not.
                     optIfOChSourceAdaptActive 1.3.6.1.2.1.10.1.1.2.1.1.2
Indicates whether the source adaptation function is activated or not.
                     optIfOTSnDAPIExpected 1.3.6.1.2.1.10.1.1.2.1.1.2
The DAPI expected by the receiver.
                     optIfOChSinkFECEnabled 1.3.6.1.2.1.10.1.1.2.1.1.3
If Forward Error Correction (FEC) is supported, this object indicates whether FEC at the OCh sink adaptation function is enabled or not.
                     optIfOTSnSAPIExpected 1.3.6.1.2.1.10.1.1.2.1.1.3
The SAPI expected by the receiver.
                     optIfOTSnTraceIdentifierAccepted 1.3.6.1.2.1.10.1.1.2.1.1.4
The actual trace identifier received.
                     optIfOTSnAcTIStatus 1.3.6.1.2.1.10.1.1.2.1.1.5
The status of the accepted Trail Trace Identifier by the receiver.
                     optIfOTSnTIMDetMode 1.3.6.1.2.1.10.1.1.2.1.1.6
Indicates the mode of the Trace Identifier Mismatch (TIM) Detection function.
                     optIfOTSnTIMActEnabled 1.3.6.1.2.1.10.1.1.2.1.1.7
Indicates whether the Trace Identifier Mismatch (TIM) Consequent Action function is enabled.
                     optIfOTSnCurrentStatus 1.3.6.1.2.1.10.1.1.2.1.1.8
Indicates the failure condition of the entity, if any.
             optIfOTSnSinkCurrentTable 1.3.6.1.2.1.10.1.1.2.2
A table of OTSn sink performance monitoring information for the current 15 minute interval.
                 optIfOTSnSinkCurrentEntry 1.3.6.1.2.1.10.1.1.2.2.1
A conceptual row that contains OTSn sink performance monitoring information of an interface for the current 15 minute interval.
                     optIfOTSnSinkCurrentSuspectedFlag 1.3.6.1.2.1.10.1.1.2.2.1.1
If true, the data in this entry may be unreliable.
                     optIfOTSnSinkCurrentInputPower 1.3.6.1.2.1.10.1.1.2.2.1.2
The optical power monitored at the input.
                     optIfOTSnSinkCurrentLowInputPower 1.3.6.1.2.1.10.1.1.2.2.1.3
The lowest optical power monitored at the input during the current interval.
                     optIfOTSnSinkCurrentHighInputPower 1.3.6.1.2.1.10.1.1.2.2.1.4
The highest optical power monitored at the input during the current interval.
                     optIfOTSnSinkCurrentLowerInputPowerThreshold 1.3.6.1.2.1.10.1.1.2.2.1.5
The lower limit threshold on input power. If optIfOTSnSinkCurrentInputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent.
                     optIfOTSnSinkCurrentUpperInputPowerThreshold 1.3.6.1.2.1.10.1.1.2.2.1.6
The upper limit threshold on input power. If optIfOTSnSinkCurrentInputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent.
             optIfOTSnSinkIntervalTable 1.3.6.1.2.1.10.1.1.2.3
A table of historical OTSn sink performance monitoring information.
                 optIfOTSnSinkIntervalEntry 1.3.6.1.2.1.10.1.1.2.3.1
A conceptual row that contains OTSn sink performance monitoring information of an interface during a particular historical interval.
                     optIfOTSnSinkIntervalNumber 1.3.6.1.2.1.10.1.1.2.3.1.1
Uniquely identifies the interval.
                     optIfOTSnSinkIntervalSuspectedFlag 1.3.6.1.2.1.10.1.1.2.3.1.2
If true, the data in this entry may be unreliable.
                     optIfOTSnSinkIntervalLastInputPower 1.3.6.1.2.1.10.1.1.2.3.1.3
The last optical power monitored at the input during the interval.
                     optIfOTSnSinkIntervalLowInputPower 1.3.6.1.2.1.10.1.1.2.3.1.4
The lowest optical power monitored at the input during the interval.
                     optIfOTSnSinkIntervalHighInputPower 1.3.6.1.2.1.10.1.1.2.3.1.5
The highest optical power monitored at the input during the interval.
             optIfOTSnSinkCurDayTable 1.3.6.1.2.1.10.1.1.2.4
A table of OTSn sink performance monitoring information for the current calendar day.
                 optIfOTSnSinkCurDayEntry 1.3.6.1.2.1.10.1.1.2.4.1
A conceptual row that contains OTSn sink performance monitoring information of an interface for the current calendar day.
                     optIfOTSnSinkCurDaySuspectedFlag 1.3.6.1.2.1.10.1.1.2.4.1.1
If true, the data in this entry may be unreliable.
                     optIfOTSnSinkCurDayLowInputPower 1.3.6.1.2.1.10.1.1.2.4.1.2
The lowest optical power monitored at the input during the current calendar day.
                     optIfOTSnSinkCurDayHighInputPower 1.3.6.1.2.1.10.1.1.2.4.1.3
The highest optical power monitored at the input during the current calendar day.
             optIfOTSnSinkPrevDayTable 1.3.6.1.2.1.10.1.1.2.5
A table of OTSn sink performance monitoring information for the previous calendar day.
                 optIfOTSnSinkPrevDayEntry 1.3.6.1.2.1.10.1.1.2.5.1
A conceptual row that contains OTSn sink performance monitoring information of an interface for the previous calendar day.
                     optIfOTSnSinkPrevDaySuspectedFlag 1.3.6.1.2.1.10.1.1.2.5.1.1
If true, the data in this entry may be unreliable.
                     optIfOTSnSinkPrevDayLastInputPower 1.3.6.1.2.1.10.1.1.2.5.1.2
The last optical power monitored at the input during the previous calendar day.
                     optIfOTSnSinkPrevDayLowInputPower 1.3.6.1.2.1.10.1.1.2.5.1.3
The lowest optical power monitored at the input during the previous calendar day.
                     optIfOTSnSinkPrevDayHighInputPower 1.3.6.1.2.1.10.1.1.2.5.1.4
The highest optical power monitored at the input during the previous calendar day.
             optIfOTSnSrcCurrentTable 1.3.6.1.2.1.10.1.1.2.6
A table of OTSn source performance monitoring information for the current 15 minute interval.
                 optIfOTSnSrcCurrentEntry 1.3.6.1.2.1.10.1.1.2.6.1
A conceptual row that contains OTSn source performance monitoring information of an interface for the current 15 minute interval.
                     optIfOTSnSrcCurrentSuspectedFlag 1.3.6.1.2.1.10.1.1.2.6.1.1
If true, the data in this entry may be unreliable.
                     optIfOTSnSrcCurrentOutputPower 1.3.6.1.2.1.10.1.1.2.6.1.2
The optical power monitored at the output.
                     optIfOTSnSrcCurrentLowOutputPower 1.3.6.1.2.1.10.1.1.2.6.1.3
The lowest optical power monitored at the output during the current interval.
                     optIfOTSnSrcCurrentHighOutputPower 1.3.6.1.2.1.10.1.1.2.6.1.4
The highest optical power monitored at the output during the current interval.
                     optIfOTSnSrcCurrentLowerOutputPowerThreshold 1.3.6.1.2.1.10.1.1.2.6.1.5
The lower limit threshold on output power. If optIfOTSnSrcCurrentOutputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent.
                     optIfOTSnSrcCurrentUpperOutputPowerThreshold 1.3.6.1.2.1.10.1.1.2.6.1.6
The upper limit threshold on output power. If optIfOTSnSrcCurrentOutputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent.
                     optIfOTSnSrcCurrentLaserTemp 1.3.6.1.2.1.10.1.1.2.6.1.7
The operating temperature of the laser.
                     optIfOTSnSrcCurrentLowLaserTemp 1.3.6.1.2.1.10.1.1.2.6.1.8
The lowest operating temperature of the laser during the current interval.
                     optIfOTSnSrcCurrentHighLaserTemp 1.3.6.1.2.1.10.1.1.2.6.1.9
The highest operating temperature of the laser during the current interval.
                     optIfOTSnSrcCurrentLowerLaserTempThreshold 1.3.6.1.2.1.10.1.1.2.6.1.10
The lower limit threshold on laser temperature. If optIfOTSnSrcCurrentLaserTemp drops to this value or below, a Threshold Crossing Alert (TCA) should be sent.
                     optIfOTSnSrcCurrentUpperLaserTempThreshold 1.3.6.1.2.1.10.1.1.2.6.1.11
The upper limit threshold on laser temperature. If optIfOTSnSrcCurrentLaserTemp reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent.
             optIfOTSnSrcIntervalTable 1.3.6.1.2.1.10.1.1.2.7
A table of historical OTSn source performance monitoring information.
                 optIfOTSnSrcIntervalEntry 1.3.6.1.2.1.10.1.1.2.7.1
A conceptual row that contains OTSn source performance monitoring information of an interface during a particular historical interval.
                     optIfOTSnSrcIntervalNumber 1.3.6.1.2.1.10.1.1.2.7.1.1
Uniquely identifies the interval.
                     optIfOTSnSrcIntervalSuspectedFlag 1.3.6.1.2.1.10.1.1.2.7.1.2
If true, the data in this entry may be unreliable.
                     optIfOTSnSrcIntervalLastOutputPower 1.3.6.1.2.1.10.1.1.2.7.1.3
The last optical power monitored at the output during the interval.
                     optIfOTSnSrcIntervalLowOutputPower 1.3.6.1.2.1.10.1.1.2.7.1.4
The lowest optical power monitored at the output during the interval.
                     optIfOTSnSrcIntervalHighOutputPower 1.3.6.1.2.1.10.1.1.2.7.1.5
The highest optical power monitored at the output during the interval.
                     optIfOTSnSrcIntervalLastLaserTemp 1.3.6.1.2.1.10.1.1.2.7.1.6
The last operating temperature of the laser during the interval.
                     optIfOTSnSrcIntervalLowLaserTemp 1.3.6.1.2.1.10.1.1.2.7.1.7
The lowest operating temperature of the laser during the interval.
                     optIfOTSnSrcIntervalHighLaserTemp 1.3.6.1.2.1.10.1.1.2.7.1.8
The highest operating temperature of the laser during the interval.
             optIfOTSnSrcCurDayTable 1.3.6.1.2.1.10.1.1.2.8
A table of OTSn source performance monitoring information for the current calendar day.
                 optIfOTSnSrcCurDayEntry 1.3.6.1.2.1.10.1.1.2.8.1
A conceptual row that contains OTSn source performance monitoring information of an interface for the current calendar day.
                     optIfOTSnSrcCurDaySuspectedFlag 1.3.6.1.2.1.10.1.1.2.8.1.1
If true, the data in this entry may be unreliable.
                     optIfOTSnSrcCurDayLowOutputPower 1.3.6.1.2.1.10.1.1.2.8.1.2
The lowest optical power monitored at the output during the current calendar day.
                     optIfOTSnSrcCurDayHighOutputPower 1.3.6.1.2.1.10.1.1.2.8.1.3
The highest optical power monitored at the output during the current calendar day.
                     optIfOTSnSrcCurDayLowLaserTemp 1.3.6.1.2.1.10.1.1.2.8.1.4
The lowest operating temperature of the laser during the current calendar day.
                     optIfOTSnSrcCurDayHighLaserTemp 1.3.6.1.2.1.10.1.1.2.8.1.5
The highest operating temperature of the laser during the current calendar day.
             optIfOTSnSrcPrevDayTable 1.3.6.1.2.1.10.1.1.2.9
A table of OTSn source performance monitoring information for the previous calendar day.
                 optIfOTSnSrcPrevDayEntry 1.3.6.1.2.1.10.1.1.2.9.1
A conceptual row that contains OTSn source performance monitoring information of an interface for the previous calendar day.
                     optIfOTSnSrcPrevDaySuspectedFlag 1.3.6.1.2.1.10.1.1.2.9.1.1
If true, the data in this entry may be unreliable.
                     optIfOTSnSrcPrevDayLastOutputPower 1.3.6.1.2.1.10.1.1.2.9.1.2
The last optical power monitored at the output during the previous calendar day.
                     optIfOTSnSrcPrevDayLowOutputPower 1.3.6.1.2.1.10.1.1.2.9.1.3
The lowest optical power monitored at the output during the previous calendar day.
                     optIfOTSnSrcPrevDayHighOutputPower 1.3.6.1.2.1.10.1.1.2.9.1.4
The highest optical power monitored at the output during the previous calendar day.
                     optIfOTSnSrcPrevDayLastLaserTemp 1.3.6.1.2.1.10.1.1.2.9.1.5
The last operating temperature of the laser during the previous calendar day.
                     optIfOTSnSrcPrevDayLowLaserTemp 1.3.6.1.2.1.10.1.1.2.9.1.6
The lowest operating temperature of the laser during the previous calendar day.
                     optIfOTSnSrcPrevDayHighLaserTemp 1.3.6.1.2.1.10.1.1.2.9.1.7
The highest operating temperature of the laser during the previous calendar day.
         optIfOMSn 1.3.6.1.2.1.10.1.1.3
             optIfOMSnConfigTable 1.3.6.1.2.1.10.1.1.3.1
A table of OMSn configuration information.
                 optIfOMSnConfigEntry 1.3.6.1.2.1.10.1.1.3.1.1
A conceptual row that contains OMSn configuration information of an interface.
                     optIfOMSnOrder 1.3.6.1.2.1.10.1.1.3.1.1.1
The number of multiplexed optical channels.
                     optIfOMSnCurrentStatus 1.3.6.1.2.1.10.1.1.3.1.1.2
Indicates the failure condition of the entity, if any.
             optIfOMSnSinkCurrentTable 1.3.6.1.2.1.10.1.1.3.2
A table of OMSn sink performance monitoring information for the current 15 minute interval.
                 optIfOMSnSinkCurrentEntry 1.3.6.1.2.1.10.1.1.3.2.1
A conceptual row that contains OMSn sink performance monitoring information of an interface for the current 15 minute interval.
                     optIfOMSnSinkCurrentSuspectedFlag 1.3.6.1.2.1.10.1.1.3.2.1.1
If true, the data in this entry may be unreliable.
                     optIfOMSnSinkCurrentAggregatedInputPower 1.3.6.1.2.1.10.1.1.3.2.1.2
The aggregated optical power of all the DWDM input channels.
                     optIfOMSnSinkCurrentLowAggregatedInputPower 1.3.6.1.2.1.10.1.1.3.2.1.3
The lowest aggregated optical power of all the DWDM input channels during the current interval.
                     optIfOMSnSinkCurrentHighAggregatedInputPower 1.3.6.1.2.1.10.1.1.3.2.1.4
The highest aggregated optical power of all the DWDM input channels during the current interval.
                     optIfOMSnSinkCurrentLowerInputPowerThreshold 1.3.6.1.2.1.10.1.1.3.2.1.5
The lower limit threshold on aggregated input power. If optIfOMSnSinkCurrentAggregatedInputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent.
                     optIfOMSnSinkCurrentUpperInputPowerThreshold 1.3.6.1.2.1.10.1.1.3.2.1.6
The upper limit threshold on aggregated input power. If optIfOMSnSinkCurrentAggregatedInputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent.
                     optIfOMSnSinkCurrentLaserTemp 1.3.6.1.2.1.10.1.1.3.2.1.7
The operating temperature of the laser.
                     optIfOMSnSinkCurrentLowLaserTemp 1.3.6.1.2.1.10.1.1.3.2.1.8
The lowest operating temperature of the laser during the current interval.
                     optIfOMSnSinkCurrentHighLaserTemp 1.3.6.1.2.1.10.1.1.3.2.1.9
The highest operating temperature of the laser during the current interval.
                     optIfOMSnSinkCurrentLowerLaserTempThreshold 1.3.6.1.2.1.10.1.1.3.2.1.10
The lower limit threshold on laser temperature. If optIfOMSnSinkCurrentLaserTemp drops to this value or below, a Threshold Crossing Alert (TCA) should be sent.
                     optIfOMSnSinkCurrentUpperLaserTempThreshold 1.3.6.1.2.1.10.1.1.3.2.1.11
The upper limit threshold on aggregated input power. If optIfOMSnSinkCurrentLaserTemp reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent.
             optIfOMSnSinkIntervalTable 1.3.6.1.2.1.10.1.1.3.3
A table of historical OMSn sink performance monitoring information.
                 optIfOMSnSinkIntervalEntry 1.3.6.1.2.1.10.1.1.3.3.1
A conceptual row that contains OMSn sink performance monitoring information of an interface during a particular historical interval.
                     optIfOMSnSinkIntervalNumber 1.3.6.1.2.1.10.1.1.3.3.1.1
Uniquely identifies the interval.
                     optIfOMSnSinkIntervalSuspectedFlag 1.3.6.1.2.1.10.1.1.3.3.1.2
If true, the data in this entry may be unreliable.
                     optIfOMSnSinkIntervalLastAggregatedInputPower 1.3.6.1.2.1.10.1.1.3.3.1.3
The last aggregated optical power of all the DWDM input channels during the interval.
                     optIfOMSnSinkIntervalLowAggregatedInputPower 1.3.6.1.2.1.10.1.1.3.3.1.4
The lowest aggregated optical power of all the DWDM input channels during the interval.
                     optIfOMSnSinkIntervalHighAggregatedInputPower 1.3.6.1.2.1.10.1.1.3.3.1.5
The highest aggregated optical power of all the DWDM input channels during the interval.
                     optIfOMSnSinkIntervalLastLaserTemp 1.3.6.1.2.1.10.1.1.3.3.1.6
The last operating temperature of the laser during the interval.
                     optIfOMSnSinkIntervalLowLaserTemp 1.3.6.1.2.1.10.1.1.3.3.1.7
The lowest operating temperature of the laser during the interval.
                     optIfOMSnSinkIntervalHighLaserTemp 1.3.6.1.2.1.10.1.1.3.3.1.8
The highest operating temperature of the laser during the interval.
             optIfOMSnSinkCurDayTable 1.3.6.1.2.1.10.1.1.3.4
A table of OMSn sink performance monitoring information for the current calendar day.
                 optIfOMSnSinkCurDayEntry 1.3.6.1.2.1.10.1.1.3.4.1
A conceptual row that contains OMSn sink performance monitoring information of an interface for the current calendar day.
                     optIfOMSnSinkCurDaySuspectedFlag 1.3.6.1.2.1.10.1.1.3.4.1.1
If true, the data in this entry may be unreliable.
                     optIfOMSnSinkCurDayLowAggregatedInputPower 1.3.6.1.2.1.10.1.1.3.4.1.2
The lowest aggregated optical power of all the DWDM input channels during the current calendar day.
                     optIfOMSnSinkCurDayHighAggregatedInputPower 1.3.6.1.2.1.10.1.1.3.4.1.3
The highest aggregated optical power of all the DWDM input channels during the current calendar day.
                     optIfOMSnSinkCurDayLowLaserTemp 1.3.6.1.2.1.10.1.1.3.4.1.4
The lowest operating temperature of the laser during the current calendar day.
                     optIfOMSnSinkCurDayHighLaserTemp 1.3.6.1.2.1.10.1.1.3.4.1.5
The highest operating temperature of the laser during the current calendar day.
             optIfOMSnSinkPrevDayTable 1.3.6.1.2.1.10.1.1.3.5
A table of OMSn sink performance monitoring information for the previous calendar day.
                 optIfOMSnSinkPrevDayEntry 1.3.6.1.2.1.10.1.1.3.5.1
A conceptual row that contains OMSn sink performance monitoring information of an interface for the previous calendar day.
                     optIfOMSnSinkPrevDaySuspectedFlag 1.3.6.1.2.1.10.1.1.3.5.1.1
If true, the data in this entry may be unreliable.
                     optIfOMSnSinkPrevDayLastAggregatedInputPower 1.3.6.1.2.1.10.1.1.3.5.1.2
The last aggregated optical power of all the DWDM input channels during the previous calendar day.
                     optIfOMSnSinkPrevDayLowAggregatedInputPower 1.3.6.1.2.1.10.1.1.3.5.1.3
The lowest aggregated optical power of all the DWDM input channels during the previous calendar day.
                     optIfOMSnSinkPrevDayHighAggregatedInputPower 1.3.6.1.2.1.10.1.1.3.5.1.4
The highest aggregated optical power of all the DWDM input channels during the previous calendar day.
                     optIfOMSnSinkPrevDayLastLaserTemp 1.3.6.1.2.1.10.1.1.3.5.1.5
The last operating temperature of the laser during the previous calendar day.
                     optIfOMSnSinkPrevDayLowLaserTemp 1.3.6.1.2.1.10.1.1.3.5.1.6
The lowest operating temperature of the laser during the previous calendar day.
                     optIfOMSnSinkPrevDayHighLaserTemp 1.3.6.1.2.1.10.1.1.3.5.1.7
The highest operating temperature of the laser during the previous calendar day.
             optIfOMSnSrcCurrentTable 1.3.6.1.2.1.10.1.1.3.6
A table of OMSn source performance monitoring information for the current 15 minute interval.
                 optIfOMSnSrcCurrentEntry 1.3.6.1.2.1.10.1.1.3.6.1
A conceptual row that contains OMSn source performance monitoring information of an interface for the current 15 minute interval.
                     optIfOMSnSrcCurrentSuspectedFlag 1.3.6.1.2.1.10.1.1.3.6.1.1
If true, the data in this entry may be unreliable.
                     optIfOMSnSrcCurrentOutputPower 1.3.6.1.2.1.10.1.1.3.6.1.2
The optical power monitored at the output.
                     optIfOMSnSrcCurrentLowOutputPower 1.3.6.1.2.1.10.1.1.3.6.1.3
The lowest optical power monitored at the output during the current interval.
                     optIfOMSnSrcCurrentHighOutputPower 1.3.6.1.2.1.10.1.1.3.6.1.4
The highest optical power monitored at the output during the current interval.
                     optIfOMSnSrcCurrentLowerOutputPowerThreshold 1.3.6.1.2.1.10.1.1.3.6.1.5
The lower limit threshold on output power. If optIfOMSnSrcCurrentOutputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent.
                     optIfOMSnSrcCurrentUpperOutputPowerThreshold 1.3.6.1.2.1.10.1.1.3.6.1.6
The upper limit threshold on output power. If optIfOMSnSrcCurrentOutputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent.
                     optIfOMSnSrcCurrentLaserTemp 1.3.6.1.2.1.10.1.1.3.6.1.7
The operating temperature of the laser.
                     optIfOMSnSrcCurrentLowLaserTemp 1.3.6.1.2.1.10.1.1.3.6.1.8
The lowest operating temperature of the laser during the current interval.
                     optIfOMSnSrcCurrentHighLaserTemp 1.3.6.1.2.1.10.1.1.3.6.1.9
The highest operating temperature of the laser during the current interval.
                     optIfOMSnSrcCurrentLowerLaserTempThreshold 1.3.6.1.2.1.10.1.1.3.6.1.10
The lower limit threshold on laser temperature. If optIfOMSnSrcCurrentLaserTemp drops to this value or below, a Threshold Crossing Alert (TCA) should be sent.
                     optIfOMSnSrcCurrentUpperLaserTempThreshold 1.3.6.1.2.1.10.1.1.3.6.1.11
The upper limit threshold on laser temperature. If optIfOMSnSrcCurrentLaserTemp reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent.
             optIfOMSnSrcIntervalTable 1.3.6.1.2.1.10.1.1.3.7
A table of historical OMSn source performance monitoring information.
                 optIfOMSnSrcIntervalEntry 1.3.6.1.2.1.10.1.1.3.7.1
A conceptual row that contains OMSn source performance monitoring information of an interface during a particular historical interval.
                     optIfOMSnSrcIntervalNumber 1.3.6.1.2.1.10.1.1.3.7.1.1
Uniquely identifies the interval.
                     optIfOMSnSrcIntervalSuspectedFlag 1.3.6.1.2.1.10.1.1.3.7.1.2
If true, the data in this entry may be unreliable.
                     optIfOMSnSrcIntervalLastOutputPower 1.3.6.1.2.1.10.1.1.3.7.1.3
The last optical power monitored at the output during the interval.
                     optIfOMSnSrcIntervalLowOutputPower 1.3.6.1.2.1.10.1.1.3.7.1.4
The lowest optical power monitored at the output during the interval.
                     optIfOMSnSrcIntervalHighOutputPower 1.3.6.1.2.1.10.1.1.3.7.1.5
The highest optical power monitored at the output during the interval.
                     optIfOMSnSrcIntervalLastLaserTemp 1.3.6.1.2.1.10.1.1.3.7.1.6
The last operating temperature of the laser during the interval.
                     optIfOMSnSrcIntervalLowLaserTemp 1.3.6.1.2.1.10.1.1.3.7.1.7
The lowest operating temperature of the laser during the interval.
                     optIfOMSnSrcIntervalHighLaserTemp 1.3.6.1.2.1.10.1.1.3.7.1.8
The highest operating temperature of the laser during the interval.
             optIfOMSnSrcCurDayTable 1.3.6.1.2.1.10.1.1.3.8
A table of OMSn source performance monitoring information for the current calendar day.
                 optIfOMSnSrcCurDayEntry 1.3.6.1.2.1.10.1.1.3.8.1
A conceptual row that contains OMSn source performance monitoring information of an interface for the current calendar day.
                     optIfOMSnSrcCurDaySuspectedFlag 1.3.6.1.2.1.10.1.1.3.8.1.1
If true, the data in this entry may be unreliable.
                     optIfOMSnSrcCurDayLowOutputPower 1.3.6.1.2.1.10.1.1.3.8.1.2
The lowest optical power monitored at the output during the current calendar day.
                     optIfOMSnSrcCurDayHighOutputPower 1.3.6.1.2.1.10.1.1.3.8.1.3
The highest optical power monitored at the output during the current calendar day.
                     optIfOMSnSrcCurDayLowLaserTemp 1.3.6.1.2.1.10.1.1.3.8.1.4
The lowest operating temperature of the laser during the current calendar day.
                     optIfOMSnSrcCurDayHighLaserTemp 1.3.6.1.2.1.10.1.1.3.8.1.5
The highest operating temperature of the laser during the current calendar day.
             optIfOMSnSrcPrevDayTable 1.3.6.1.2.1.10.1.1.3.9
A table of OMSn source performance monitoring information for the previous calendar day.
                 optIfOMSnSrcPrevDayEntry 1.3.6.1.2.1.10.1.1.3.9.1
A conceptual row that contains OMSn source performance monitoring information of an interface for the previous calendar day.
                     optIfOMSnSrcPrevDaySuspectedFlag 1.3.6.1.2.1.10.1.1.3.9.1.1
If true, the data in this entry may be unreliable.
                     optIfOMSnSrcPrevDayLastOutputPower 1.3.6.1.2.1.10.1.1.3.9.1.2
The last optical power monitored at the output during the previous calendar day.
                     optIfOMSnSrcPrevDayLowOutputPower 1.3.6.1.2.1.10.1.1.3.9.1.3
The lowest optical power monitored at the output during the previous calendar day.
                     optIfOMSnSrcPrevDayHighOutputPower 1.3.6.1.2.1.10.1.1.3.9.1.4
The highest optical power monitored at the output during the previous calendar day.
                     optIfOMSnSrcPrevDayLastLaserTemp 1.3.6.1.2.1.10.1.1.3.9.1.5
The last operating temperature of the laser during the previous calendar day.
                     optIfOMSnSrcPrevDayLowLaserTemp 1.3.6.1.2.1.10.1.1.3.9.1.6
The lowest operating temperature of the laser during the previous calendar day.
                     optIfOMSnSrcPrevDayHighLaserTemp 1.3.6.1.2.1.10.1.1.3.9.1.7
The highest operating temperature of the laser during the previous calendar day.
         optIfOCh 1.3.6.1.2.1.10.1.1.4
             optIfOTUk 1.3.6.1.2.1.10.1.1.4.1
                 optIfOTUkConfigTable 1.3.6.1.2.1.10.1.1.4.1.1
A table of OTUk configuration information.
                     optIfOTUkConfigEntry 1.3.6.1.2.1.10.1.1.4.1.1.1
A conceptual row that contains OTUk configuration information of an interface.
                         optIfOTUkTraceIdentifierTransmitted 1.3.6.1.2.1.10.1.1.4.1.1.1.1
The trace identifier transmitted.
                         optIfOTUkDAPIExpected 1.3.6.1.2.1.10.1.1.4.1.1.1.2
The DAPI expected by the receiver.
                         optIfOTUkSAPIExpected 1.3.6.1.2.1.10.1.1.4.1.1.1.3
The SAPI expected by the receiver.
                         optIfOTUkTraceIdentifierAccepted 1.3.6.1.2.1.10.1.1.4.1.1.1.4
The actual trace identifier accepted.
                         optIfOTUkAcTIStatus 1.3.6.1.2.1.10.1.1.4.1.1.1.5
The status of the accepted Trail Trace Identifier by the receiver.
                         optIfOTUkTIMDetMode 1.3.6.1.2.1.10.1.1.4.1.1.1.6
Indicates the mode of the Trace Identifier Mismatch (TIM) Detection function.
                         optIfOTUkTIMActEnabled 1.3.6.1.2.1.10.1.1.4.1.1.1.7
Indicates whether the Trace Identifier Mismatch (TIM) Consequent Action function is enabled
                         optIfOTUkDEGThr 1.3.6.1.2.1.10.1.1.4.1.1.1.8
Indicates the threshold level for declaring a performance monitoring (PM) Second to be bad. A PM Second is declared bad if the percentage of detected errored blocks in that second is greater than or equal to DEGTHR.
                         optIfOTUkDEGM 1.3.6.1.2.1.10.1.1.4.1.1.1.9
Indicates the threshold level for declaring a Degraded Signal defect (dDEG). A dDEG shall be declared if DEGM consecutive bad PM Seconds are detected.
                         optIfOTUkCurrentStatus 1.3.6.1.2.1.10.1.1.4.1.1.1.10
Indicates the failure condition of the entity, if any.
             optIfODUkT 1.3.6.1.2.1.10.1.1.4.2
                 optIfODUkTSinkConfigTable 1.3.6.1.2.1.10.1.1.4.2.1
A table of ODUkT TCM Sink configuration information.
                     optIfODUkTSinkConfigEntry 1.3.6.1.2.1.10.1.1.4.2.1.1
A conceptual row that contains ODUkT Sink configuration information of an interface.
                         optIfODUkTDAPIExpected 1.3.6.1.2.1.10.1.1.4.2.1.1.2
The DAPI expected by the receiver.
                         optIfODUkTSAPIExpected 1.3.6.1.2.1.10.1.1.4.2.1.1.3
The SAPI expected by the receiver.
                         optIfODUkTTraceIdentifierAccepted 1.3.6.1.2.1.10.1.1.4.2.1.1.4
The actual trace identifier accepted.
                         optIfODUkTAcTIStatus 1.3.6.1.2.1.10.1.1.4.2.1.1.5
The status of the accepted Trail Trace Identifier by the receiver.
                         optIfODUkTTIMDetMode 1.3.6.1.2.1.10.1.1.4.2.1.1.6
Indicates the mode of the Trace Identifier Mismatch (TIM) Detection function.
                         optIfODUkTTIMActEnabled 1.3.6.1.2.1.10.1.1.4.2.1.1.7
Indicates whether the Trace Identifier Mismatch (TIM) Consequent Action function is enabled.
                         optIfODUkTDEGThr 1.3.6.1.2.1.10.1.1.4.2.1.1.8
Indicates the threshold level for declaring a performance monitoring (PM) Second to be bad. A PM Second is declared bad if the percentage of detected errored blocks in that second is greater than or equal to DEGTHR.
                         optIfODUkTDEGM 1.3.6.1.2.1.10.1.1.4.2.1.1.9
Indicates the threshold level for declaring a Degraded Signal defect (dDEG). A dDEG shall be declared if DEGM consecutive bad PM Seconds are detected.
                         optIfODUkTSinkMode 1.3.6.1.2.1.10.1.1.4.2.1.1.10
Controls the detection of the TCM sub-fields at the Sink: If the value is TRANSPARENT, the TCM sub-fields were not inserted. If the value is OPERATIONAL, then: - Trail Trace Identifier is inserted in the TTI byte position - Backward Defect Indication is inserted in the BDI bit position - Bit Interleaved Parity (BIP-8) is inserted in the BIP8 byte position - Bits 6, 7 and 8 of byte BI shall be fixed to 000 (reserved)
                         optIfODUkTSinkLockSignalAdminState 1.3.6.1.2.1.10.1.1.4.2.1.1.11
Provides the capability to provision the LOCK signal, which is one of the ODUk maintenance signals, at the ODUKT sink. When a Tandem Connection endpoint is set to admin state locked, it inserts the ODUk-LCK signal in the sink direction.
                         optIfODUkTCurrentStatus 1.3.6.1.2.1.10.1.1.4.2.1.1.12
Indicates the failure condition of the entity, if any.
                 optIfODUkTSourceConfigTable 1.3.6.1.2.1.10.1.1.4.2.2
A table of ODUkT TCM Source configuration information.
                     optIfODUkTSourceConfigEntry 1.3.6.1.2.1.10.1.1.4.2.2.1
A conceptual row that contains ODUkT Source configuration information of an interface.
                         optIfODUkTTcmId 1.3.6.1.2.1.10.1.1.4.2.2.1.1
Value of the TCM level
                         optIfODUkTTraceIdentifierTransmitted 1.3.6.1.2.1.10.1.1.4.2.2.1.2
The trace identifier transmitted.
                         optIfODUkTSourceMode 1.3.6.1.2.1.10.1.1.4.2.2.1.3
Controls the detection of the TCM sub-fields at the Source: If the value is TRANSPARENT, all information shall be passed through transparently, with the exception of the TCM ACT. If the value is OPERATIONAL, then: - Trail Trace Identifier is inserted in the TTI byte position - Backward Defect Indication is inserted in the BDI bit position - Bit Interleaved Parity (BIP-8) is inserted in the BIP8 byte position - Bits 6, 7 and 8 of byte BI shall be fixed to 000 (reserved)
                         optIfODUkTSourceLockSignalAdminState 1.3.6.1.2.1.10.1.1.4.2.2.1.4
Provides the capability to provision the LOCK signal, which is one of the ODUk maintenance signals, at the source. When a Tandem Connection endpoint is set to admin state locked, it inserts the ODUk-LCK signal in the source direction.
             optIfODUkP 1.3.6.1.2.1.10.1.1.4.3
                 optIfODUkPConfigTable 1.3.6.1.2.1.10.1.1.4.3.1
A table of ODUkP configuration information.
                     optIfODUkPConfigEntry 1.3.6.1.2.1.10.1.1.4.3.1.1
A conceptual row that contains ODUkP configuration information of an interface.
                         optIfODUkPTraceIdentifierTransmitted 1.3.6.1.2.1.10.1.1.4.3.1.1.1
The trace identifier transmitted.
                         optIfODUkPDAPIExpected 1.3.6.1.2.1.10.1.1.4.3.1.1.2
The DAPI expected by the receiver.
                         optIfODUkPSAPIExpected 1.3.6.1.2.1.10.1.1.4.3.1.1.3
The SAPI expected by the receiver.
                         optIfODUkPTraceIdentifierAccepted 1.3.6.1.2.1.10.1.1.4.3.1.1.4
The actual trace identifier accepted.
                         optIfODUkPAcTIStatus 1.3.6.1.2.1.10.1.1.4.3.1.1.5
The status of the accepted Trail Trace Identifier by the receiver.
                         optIfODUkPTIMDetMode 1.3.6.1.2.1.10.1.1.4.3.1.1.6
Indicates the mode of the Trace Identifier Mismatch (TIM) Detection function.
                         optIfODUkPTIMActEnabled 1.3.6.1.2.1.10.1.1.4.3.1.1.7
Indicates whether the Trace Identifier Mismatch (TIM) Consequent Action function is enabled.
                         optIfODUkPDEGThr 1.3.6.1.2.1.10.1.1.4.3.1.1.8
Indicates the threshold level for declaring a performance monitoring (PM) Second to be bad. A PM Second is declared bad if the percentage of detected errored blocks in that second is greater than or equal to DEGTHR.
                         optIfODUkPDEGM 1.3.6.1.2.1.10.1.1.4.3.1.1.9
Indicates the threshold level for declaring a Degraded Signal defect (dDEG). A dDEG shall be declared if DEGM consecutive bad PM Seconds are detected.
                         optIfODUkPCurrentStatus 1.3.6.1.2.1.10.1.1.4.3.1.1.10
Indicates the failure condition of the entity, if any.
                         optIfODUkPPayloadTypeTransmitted 1.3.6.1.2.1.10.1.1.4.3.1.1.11
The payload type signal transmitted.
                         optIfODUkPPayloadTypeExpected 1.3.6.1.2.1.10.1.1.4.3.1.1.12
The payload type signal expected by the receiver.
                         optIfODUkPPayloadTypeAccepted 1.3.6.1.2.1.10.1.1.4.3.1.1.13
The actual payload type signal accepted.
                         optIfODUkPActiveAdaptFuncSource 1.3.6.1.2.1.10.1.1.4.3.1.1.14
When an ODUkP termination point supports multiple adaptation functions, this object indicates the active adaptation function at the interface port.
                         optIfODUkPActiveAdaptFuncSink 1.3.6.1.2.1.10.1.1.4.3.1.1.15
When an ODUkP termination point supports multiple adaptation functions, this object indicates the active adaptation function at the interface port.
             optIfOChConfigTable 1.3.6.1.2.1.10.1.1.4.4
A table of OCh configuration information.
                 optIfOChConfigEntry 1.3.6.1.2.1.10.1.1.4.4.1
A conceptual row that contains OCh configuration information of an interface.
                     optIfOChCurrentStatus 1.3.6.1.2.1.10.1.1.4.4.1.4
Indicates the failure condition of the entity, if any.
             optIfOChSinkCurrentTable 1.3.6.1.2.1.10.1.1.4.5
A table of OCh sink performance monitoring information for the current 15 minute interval.
                 optIfOChSinkCurrentEntry 1.3.6.1.2.1.10.1.1.4.5.1
A conceptual row that contains OCh sink performance monitoring information for an interface for the current 15 minute interval.
                     optIfOChSinkCurrentSuspectedFlag 1.3.6.1.2.1.10.1.1.4.5.1.1
If true, the data in this entry may be unreliable.
                     optIfOChSinkCurrentInputPower 1.3.6.1.2.1.10.1.1.4.5.1.2
The optical power monitored at the input.
                     optIfOChSinkCurrentLowInputPower 1.3.6.1.2.1.10.1.1.4.5.1.3
The lowest optical power monitored at the input during the current interval.
                     optIfOChSinkCurrentHighInputPower 1.3.6.1.2.1.10.1.1.4.5.1.4
The highest optical power monitored at the input during the current interval.
                     optIfOChSinkCurrentLowerInputPowerThreshold 1.3.6.1.2.1.10.1.1.4.5.1.5
The lower limit threshold on input power. If optIfOChSinkCurrentInputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent.
                     optIfOChSinkCurrentUpperInputPowerThreshold 1.3.6.1.2.1.10.1.1.4.5.1.6
The upper limit threshold on input power. If optIfOChSinkCurrentInputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent.
             optIfOChSinkIntervalTable 1.3.6.1.2.1.10.1.1.4.6
A table of historical OCh sink performance monitoring information.
                 optIfOChSinkIntervalEntry 1.3.6.1.2.1.10.1.1.4.6.1
A conceptual row that contains OCh sink performance monitoring information of an interface during a particular historical interval.
                     optIfOChSinkIntervalNumber 1.3.6.1.2.1.10.1.1.4.6.1.1
Uniquely identifies the interval.
                     optIfOChSinkIntervalSuspectedFlag 1.3.6.1.2.1.10.1.1.4.6.1.2
If true, the data in this entry may be unreliable.
                     optIfOChSinkIntervalLastInputPower 1.3.6.1.2.1.10.1.1.4.6.1.3
The last optical power monitored at the input during the interval.
                     optIfOChSinkIntervalLowInputPower 1.3.6.1.2.1.10.1.1.4.6.1.4
The lowest optical power monitored at the input during the interval.
                     optIfOChSinkIntervalHighInputPower 1.3.6.1.2.1.10.1.1.4.6.1.5
The highest optical power monitored at the input during the interval.
             optIfOChSinkCurDayTable 1.3.6.1.2.1.10.1.1.4.7
A table of OCh sink performance monitoring information for the current calendar day.
                 optIfOChSinkCurDayEntry 1.3.6.1.2.1.10.1.1.4.7.1
A conceptual row that contains OCh sink performance monitoring information of an interface for the current calendar day.
                     optIfOChSinkCurDaySuspectedFlag 1.3.6.1.2.1.10.1.1.4.7.1.1
If true, the data in this entry may be unreliable.
                     optIfOChSinkCurDayLowInputPower 1.3.6.1.2.1.10.1.1.4.7.1.2
The lowest optical power monitored at the input during the current calendar day.
                     optIfOChSinkCurDayHighInputPower 1.3.6.1.2.1.10.1.1.4.7.1.3
The highest optical power monitored at the input during the current calendar day.
             optIfOChSinkPrevDayTable 1.3.6.1.2.1.10.1.1.4.8
A table of OCh sink performance monitoring information for the previous calendar day.
                 optIfOChSinkPrevDayEntry 1.3.6.1.2.1.10.1.1.4.8.1
A conceptual row that contains OCh sink performance monitoring information of an interface for the previous calendar day.
                     optIfOChSinkPrevDaySuspectedFlag 1.3.6.1.2.1.10.1.1.4.8.1.1
If true, the data in this entry may be unreliable.
                     optIfOChSinkPrevDayLastInputPower 1.3.6.1.2.1.10.1.1.4.8.1.2
The last optical power monitored at the input during the previous calendar day.
                     optIfOChSinkPrevDayLowInputPower 1.3.6.1.2.1.10.1.1.4.8.1.3
The lowest optical power monitored at the input during the previous calendar day.
                     optIfOChSinkPrevDayHighInputPower 1.3.6.1.2.1.10.1.1.4.8.1.4
The highest optical power monitored at the input during the previous calendar day.
             optIfOChSrcCurrentTable 1.3.6.1.2.1.10.1.1.4.9
A table of OCh source performance monitoring information for the current 15 minute interval.
                 optIfOChSrcCurrentEntry 1.3.6.1.2.1.10.1.1.4.9.1
A conceptual row that contains OCh source performance monitoring information of an interface for the current 15 minute interval.
                     optIfOChSrcCurrentSuspectedFlag 1.3.6.1.2.1.10.1.1.4.9.1.1
If true, the data in this entry may be unreliable.
                     optIfOChSrcCurrentOutputPower 1.3.6.1.2.1.10.1.1.4.9.1.2
The optical power monitored at the output.
                     optIfOChSrcCurrentLowOutputPower 1.3.6.1.2.1.10.1.1.4.9.1.3
The lowest optical power monitored at the output during the current interval.
                     optIfOChSrcCurrentHighOutputPower 1.3.6.1.2.1.10.1.1.4.9.1.4
The highest optical power monitored at the output during the current interval.
                     optIfOChSrcCurrentLowerOutputPowerThreshold 1.3.6.1.2.1.10.1.1.4.9.1.5
The lower limit threshold on output power. If optIfOChSrcCurrentOutputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent.
                     optIfOChSrcCurrentUpperOutputPowerThreshold 1.3.6.1.2.1.10.1.1.4.9.1.6
The upper limit threshold on output power. If optIfOChSrcCurrentOutputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent.
                     optIfOChSrcCurrentLaserTemp 1.3.6.1.2.1.10.1.1.4.9.1.7
The operating temperature of the laser.
                     optIfOChSrcCurrentLowLaserTemp 1.3.6.1.2.1.10.1.1.4.9.1.8
The lowest operating temperature of the laser during the current interval.
                     optIfOChSrcCurrentHighLaserTemp 1.3.6.1.2.1.10.1.1.4.9.1.9
The highest operating temperature of the laser during the current interval.
                     optIfOChSrcCurrentLowerLaserTempThreshold 1.3.6.1.2.1.10.1.1.4.9.1.10
The lower limit threshold on laser temperature. If optIfOChSrcCurrentLaserTemp drops to this value or below, a Threshold Crossing Alert (TCA) should be sent.
                     optIfOChSrcCurrentUpperLaserTempThreshold 1.3.6.1.2.1.10.1.1.4.9.1.11
The upper limit threshold on laser temperature. If optIfOChSrcCurrentLaserTemp reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent.
             optIfOChSrcIntervalTable 1.3.6.1.2.1.10.1.1.4.10
A table of historical OCh source performance monitoring information.
                   optIfOChSrcIntervalEntry 1.3.6.1.2.1.10.1.1.4.10.1
A conceptual row that contains OCh source performance monitoring information of an interface during a particular historical interval.
                       optIfOChSrcIntervalNumber 1.3.6.1.2.1.10.1.1.4.10.1.1
Uniquely identifies the interval.
                       optIfOChSrcIntervalSuspectedFlag 1.3.6.1.2.1.10.1.1.4.10.1.2
If true, the data in this entry may be unreliable.
                       optIfOChSrcIntervalLastOutputPower 1.3.6.1.2.1.10.1.1.4.10.1.3
The last optical power monitored at the output during the interval.
                       optIfOChSrcIntervalLowOutputPower 1.3.6.1.2.1.10.1.1.4.10.1.4
The lowest optical power monitored at the output during the interval.
                       optIfOChSrcIntervalHighOutputPower 1.3.6.1.2.1.10.1.1.4.10.1.5
The highest optical power monitored at the output during the interval.
                       optIfOChSrcIntervalLastLaserTemp 1.3.6.1.2.1.10.1.1.4.10.1.6
The last operating temperature of the laser during the interval.
                       optIfOChSrcIntervalLowLaserTemp 1.3.6.1.2.1.10.1.1.4.10.1.7
The lowest operating temperature of the laser during the interval.
                       optIfOChSrcIntervalHighLaserTemp 1.3.6.1.2.1.10.1.1.4.10.1.8
The highest operating temperature of the laser during the interval.
             optIfOChSrcCurDayTable 1.3.6.1.2.1.10.1.1.4.11
A table of OCh source performance monitoring information for the current calendar day.
                   optIfOChSrcCurDayEntry 1.3.6.1.2.1.10.1.1.4.11.1
A conceptual row that contains OCh source performance monitoring information of an interface for the current calendar day.
                       optIfOChSrcCurDaySuspectedFlag 1.3.6.1.2.1.10.1.1.4.11.1.1
If true, the data in this entry may be unreliable.
                       optIfOChSrcCurDayLowOutputPower 1.3.6.1.2.1.10.1.1.4.11.1.2
The lowest optical power monitored at the output during the current calendar day.
                       optIfOChSrcCurDayHighOutputPower 1.3.6.1.2.1.10.1.1.4.11.1.3
The highest optical power monitored at the output during the current calendar day.
                       optIfOChSrcCurDayLowLaserTemp 1.3.6.1.2.1.10.1.1.4.11.1.4
The lowest operating temperature of the laser during the current calendar day.
                       optIfOChSrcCurDayHighLaserTemp 1.3.6.1.2.1.10.1.1.4.11.1.5
The highest operating temperature of the laser during the current calendar day.
             optIfOChSrcPrevDayTable 1.3.6.1.2.1.10.1.1.4.12
A table of OCh source performance monitoring information for the previous calendar day.
                   optIfOChSrcPrevDayEntry 1.3.6.1.2.1.10.1.1.4.12.1
A conceptual row that contains OCh source performance monitoring information of an interface for the previous calendar day.
                       optIfOChSrcPrevDaySuspectedFlag 1.3.6.1.2.1.10.1.1.4.12.1.1
If true, the data in this entry may be unreliable.
                       optIfOChSrcPrevDayLastOutputPower 1.3.6.1.2.1.10.1.1.4.12.1.2
The last optical power monitored at the output during the previous calendar day.
                       optIfOChSrcPrevDayLowOutputPower 1.3.6.1.2.1.10.1.1.4.12.1.3
The lowest optical power monitored at the output during the previous calendar day.
                       optIfOChSrcPrevDayHighOutputPower 1.3.6.1.2.1.10.1.1.4.12.1.4
The highest optical power monitored at the output during the previous calendar day.
                       optIfOChSrcPrevDayLastLaserTemp 1.3.6.1.2.1.10.1.1.4.12.1.5
The last operating temperature of the laser during the previous calendar day.
                       optIfOChSrcPrevDayLowLaserTemp 1.3.6.1.2.1.10.1.1.4.12.1.6
The lowest operating temperature of the laser during the previous calendar day.
                       optIfOChSrcPrevDayHighLaserTemp 1.3.6.1.2.1.10.1.1.4.12.1.7
The highest operating temperature of the laser during the previous calendar day.
     optIfConfs 1.3.6.1.2.1.10.1.2
         optIfGroups 1.3.6.1.2.1.10.1.2.1
             optIfPerfMonGroup 1.3.6.1.2.1.10.1.2.1.1
A collection of performance monitoring interval objects.
             optIfOTSnConfigGroup 1.3.6.1.2.1.10.1.2.1.2
A collection of OTSn configuration objects.
             optIfOTSnPMGroup 1.3.6.1.2.1.10.1.2.1.3
A collection of OTSn performance monitoring objects.
             optIfOMSnConfigGroup 1.3.6.1.2.1.10.1.2.1.4
A collection of OMSn configuration objects.
             optIfOMSnPMGroup 1.3.6.1.2.1.10.1.2.1.5
A collection of OMSn performance monitoring objects.
             optIfOChConfigGroup 1.3.6.1.2.1.10.1.2.1.6
A collection of OCh configuration objects.
             optIfOChPMGroup 1.3.6.1.2.1.10.1.2.1.7
A collection of OCh performance monitoring objects.
             optIfOTUkConfigGroup 1.3.6.1.2.1.10.1.2.1.8
A collection of OTUk configuration objects.
             optIfODUkTGroup 1.3.6.1.2.1.10.1.2.1.9
A collection of ODUkT configuration objects.
             optIfODUkPGroup 1.3.6.1.2.1.10.1.2.1.10
A collection of ODUkP configuration objects.
         optIfCompl 1.3.6.1.2.1.10.1.2.2
             optIfMinCompl 1.3.6.1.2.1.10.1.2.2.1
The minimal implementation requirements for this MIB module.
             optIfFullCompl 1.3.6.1.2.1.10.1.2.2.2
The full implementation requirements for this MIB module.