OPTIX-SDH-PER-MIB: View SNMP OID List / Download MIB

VENDOR: HUAWEI


 Home MIB: OPTIX-SDH-PER-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 optixPerformance 1.3.6.1.4.1.2011.2.25.3.10.20
This module MIB describes the Optix Perfomance.
       perMonitorTime 1.3.6.1.4.1.2011.2.25.3.10.20.10
             per15mMonitorTime 1.3.6.1.4.1.2011.2.25.3.10.20.10.10
                   per15mMonitorStartTime 1.3.6.1.4.1.2011.2.25.3.10.20.10.10.10 dateandtime read-write
Start date and time of 15 minutes PM period.When system enter the per15mMonitorStartTime,15 minutes PM starts.the per15mMonitorStartTime should not ealier than current date and time, specially,when it is equal to 1990-00-00 00:00:00,15 minutes PM starts immediately.reset the per15mMonitorStartTime will terminate current 15 minutes PM period.When system enter the per15mMonitorEndTime, the per15mMonitorStartTime will be reset to zero.
                   per15mMonitorEndTime 1.3.6.1.4.1.2011.2.25.3.10.20.10.10.20 dateandtime read-write
End date and time of 15 minutes PM period.you need set the per15mMonitorStartTime before set the per15mMonitorEndTime,and per15mMonitorStartTime should earlier than the per15mMonitorEndTime,specially,when the per15mMonitorEndTime is equal to 1990-00-00 00:00:00,15 minutes PM ends immediately. When system enter the per15mMonitorEndTime,the per15mMonitorEndTime will be reset to zero.
             per24hMonitorTime 1.3.6.1.4.1.2011.2.25.3.10.20.10.20
                   per24hMonitorStartTime 1.3.6.1.4.1.2011.2.25.3.10.20.10.20.10 dateandtime read-write
Start date and time of one day PM period.When system enter the per24hMonitorStartTime,one day PM starts.the per24hMonitorStartTime should not ealier than current date and time, specially,when it is equal to 1990-00-00 00:00:00,one day PM starts immediately.reset the per24hMonitorStartTime will terminate current one day PM period.When system enter the per24hMonitorEndTime, the per24hMonitorStartTime will be reset to zero.
                   per24hMonitorEndTime 1.3.6.1.4.1.2011.2.25.3.10.20.10.20.20 dateandtime read-write
End date and time of one day PM period.you need set the per24hMonitorStartTime before set the per24hMonitorEndTime,and per24hMonitorStartTime should earlier than the per24hMonitorEndTime,specially,when the per24hMonitorEndTime is equal to 1990-00-00 00:00:00,one day PM ends immediately. When system enter the per24hMonitorEndTime,the per24hMonitorEndTime will be reset to zero.
       perMonitorData 1.3.6.1.4.1.2011.2.25.3.10.20.20
             per15mMonitoring 1.3.6.1.4.1.2011.2.25.3.10.20.20.10
                   per15mCurrentDataTable 1.3.6.1.4.1.2011.2.25.3.10.20.20.10.10 no-access
15 minutes PM period current data table
                         per15mCurrentDataEntry 1.3.6.1.4.1.2011.2.25.3.10.20.20.10.10.1 no-access
15 minutes PM period current data entry
                             per15mCurrentDataBoardNo 1.3.6.1.4.1.2011.2.25.3.10.20.20.10.10.1.1 gauge32 read-only
Card No.:between 1 and 20
                             per15mCurrentDataOpticalPort 1.3.6.1.4.1.2011.2.25.3.10.20.20.10.10.1.2 gauge32 read-only
Optical port No.:values depend on type of card
                             per15mCurrentDataPathNumber 1.3.6.1.4.1.2011.2.25.3.10.20.20.10.10.1.3 gauge32 read-only
Path No.:values depend on type of card
                             per15mCurrentDataEventID 1.3.6.1.4.1.2011.2.25.3.10.20.20.10.10.1.4 sdhperformanceeventtype read-only
Event ID:values depend on type of card
                             per15mCurrentDataStartTime 1.3.6.1.4.1.2011.2.25.3.10.20.20.10.10.1.5 dateandtime read-only
start date and time: start date and time of current 15 minutes PM period.
                             per15mCurrentDataValue 1.3.6.1.4.1.2011.2.25.3.10.20.20.10.10.1.6 gauge32 read-only
Current data value: value of current 15 minutes PM period register.the units of value vary as the PM event,fo example,the unit of RSUAS is 'second',while the unit of RSBBE is 'count'.
                             per15mCurrentDataReset 1.3.6.1.4.1.2011.2.25.3.10.20.20.10.10.1.7 integer read-write
Current data reset: reset value of current 15 minutes PM period register to zero. Enumeration: 'reset': 1.
                   per15mHistoryDataTable 1.3.6.1.4.1.2011.2.25.3.10.20.20.10.20 no-access
15 minutes PM period historic data table
                         per15mHistoryDataEntry 1.3.6.1.4.1.2011.2.25.3.10.20.20.10.20.1 no-access
15 minutes PM period historic data entry
                             per15mHistoryDataBoardNo 1.3.6.1.4.1.2011.2.25.3.10.20.20.10.20.1.1 gauge32 read-only
Card No.:between 1 and 20
                             per15mHistoryDataOpticalPort 1.3.6.1.4.1.2011.2.25.3.10.20.20.10.20.1.2 gauge32 read-only
Optical port No.:values depend on type of card
                             per15mHistoryDataPathNumber 1.3.6.1.4.1.2011.2.25.3.10.20.20.10.20.1.3 gauge32 read-only
Path No.:values depend on type of card
                             per15mHistoryDataEventID 1.3.6.1.4.1.2011.2.25.3.10.20.20.10.20.1.4 sdhperformanceeventtype read-only
Event ID:values depend on type of card
                             per15mHistoryDataStartTime 1.3.6.1.4.1.2011.2.25.3.10.20.20.10.20.1.5 dateandtime read-only
start date and time: start date and time of special 15 minutes PM period.
                             per15mHistoryDataValue 1.3.6.1.4.1.2011.2.25.3.10.20.20.10.20.1.6 gauge32 read-only
Historic data value: value of special 15 minutes PM period register.the units of value vary as the PM event,fo example,the unit of RSUAS is 'second',while the unit of RSBBE is 'count'.
                             per15mHistoryDataReset 1.3.6.1.4.1.2011.2.25.3.10.20.20.10.20.1.7 integer read-write
Historic data reset: reset value of special 15 minutes PM period register to zero. Enumeration: 'reset': 1.
             per24hMonitoring 1.3.6.1.4.1.2011.2.25.3.10.20.20.20
                   per24hCurrentDataTable 1.3.6.1.4.1.2011.2.25.3.10.20.20.20.10 no-access
one day PM period current data table
                         per24hCurrentDataEntry 1.3.6.1.4.1.2011.2.25.3.10.20.20.20.10.1 no-access
one day PM period current data entry
                             per24hCurrentDataBoardNo 1.3.6.1.4.1.2011.2.25.3.10.20.20.20.10.1.1 gauge32 read-only
Card No.:between 1 and 20
                             per24hCurrentDataOpticalPort 1.3.6.1.4.1.2011.2.25.3.10.20.20.20.10.1.2 gauge32 read-only
Optical port No.:values depend on type of card
                             per24hCurrentDataPathNumber 1.3.6.1.4.1.2011.2.25.3.10.20.20.20.10.1.3 gauge32 read-only
Path No.:values depend on type of card
                             per24hCurrentDataEventID 1.3.6.1.4.1.2011.2.25.3.10.20.20.20.10.1.4 sdhperformanceeventtype read-only
Event ID:values depend on type of card
                             per24hCurrentDataStartTime 1.3.6.1.4.1.2011.2.25.3.10.20.20.20.10.1.5 dateandtime read-only
start date and time: start date and time of current one day PM period.
                             per24hCurrentDataValue 1.3.6.1.4.1.2011.2.25.3.10.20.20.20.10.1.6 gauge32 read-only
Current data value: value of current one day PM period register.the units of value vary as the PM event,fo example,the unit of RSUAS is 'second',while the unit of RSBBE is 'count'.
                             per24hCurrentDataReset 1.3.6.1.4.1.2011.2.25.3.10.20.20.20.10.1.7 integer read-write
Current data reset: reset value of current one day PM period register to zero. Enumeration: 'reset': 1.
                   per24hHistoryDataTable 1.3.6.1.4.1.2011.2.25.3.10.20.20.20.20 no-access
one day PM period historic data table
                         per24hHistoryDataEntry 1.3.6.1.4.1.2011.2.25.3.10.20.20.20.20.1 no-access
one day PM period historic data entry
                             per24hHistoryDataBoardNo 1.3.6.1.4.1.2011.2.25.3.10.20.20.20.20.1.1 gauge32 read-only
Card No.:between 1 and 20
                             per24hHistoryDataOpticalPort 1.3.6.1.4.1.2011.2.25.3.10.20.20.20.20.1.2 gauge32 read-only
Optical port No.:values depend on type of card
                             per24hHistoryDataPathNumber 1.3.6.1.4.1.2011.2.25.3.10.20.20.20.20.1.3 gauge32 read-only
Path No.:values depend on type of card
                             per24hHistoryDataEventID 1.3.6.1.4.1.2011.2.25.3.10.20.20.20.20.1.4 sdhperformanceeventtype read-only
Event ID:values depend on type of card
                             per24hHistoryDataStartTime 1.3.6.1.4.1.2011.2.25.3.10.20.20.20.20.1.5 dateandtime read-only
start date and time: start date and time of special one day PM period.
                             per24hHistoryDataValue 1.3.6.1.4.1.2011.2.25.3.10.20.20.20.20.1.6 gauge32 read-only
Historic data value: value of special one day PM period register.the units of value vary as the PM event,fo example,the unit of RSUAS is 'second',while the unit of RSBBE is 'count'.
                             per24hHistoryDataReset 1.3.6.1.4.1.2011.2.25.3.10.20.20.20.20.1.7 integer read-write
Historic data reset: reset value of special one day PM period register to zero. Enumeration: 'reset': 1.
       perThreshold 1.3.6.1.4.1.2011.2.25.3.10.20.30
             per15mThreshold 1.3.6.1.4.1.2011.2.25.3.10.20.30.10
                   per15mThresholdTable 1.3.6.1.4.1.2011.2.25.3.10.20.30.10.10 no-access
15 minutes PM period threshold table
                         per15mThresholdEntry 1.3.6.1.4.1.2011.2.25.3.10.20.30.10.10.1 no-access
15 minutes PM period threshold entry
                             per15mThresholdBoardNo 1.3.6.1.4.1.2011.2.25.3.10.20.30.10.10.1.1 gauge32 read-only
Card No.:between 1 and 20
                             per15mThresholdOpticalPort 1.3.6.1.4.1.2011.2.25.3.10.20.30.10.10.1.2 gauge32 read-only
Optical port No.:values depend on type of card
                             per15mThresholdPathNumber 1.3.6.1.4.1.2011.2.25.3.10.20.30.10.10.1.3 gauge32 read-only
Path No.:values depend on type of card
                             per15mThresholdEventID 1.3.6.1.4.1.2011.2.25.3.10.20.30.10.10.1.4 sdhperformanceeventtype read-only
Event ID:values depend on type of card
                             per15mThresholdHighValue 1.3.6.1.4.1.2011.2.25.3.10.20.30.10.10.1.5 gauge32 read-write
High threshold value: some parameters have two thresholds,such as RSBBE, while others have single threshold,such as RSSES.
                             per15mThresholdLowValue 1.3.6.1.4.1.2011.2.25.3.10.20.30.10.10.1.6 gauge32 read-write
Low threshold value: specially,some parameters have single threshold, so their Low threshold should always be zero.
                             per15mThresholdReset 1.3.6.1.4.1.2011.2.25.3.10.20.30.10.10.1.7 integer read-write
Threshold reset: reset both high threshold and low threshold(if has). Enumeration: 'reset': 1.
             per24hThreshold 1.3.6.1.4.1.2011.2.25.3.10.20.30.20
                   per24hThresholdTable 1.3.6.1.4.1.2011.2.25.3.10.20.30.20.10 no-access
one day PM period threshold table
                         per24hThresholdEntry 1.3.6.1.4.1.2011.2.25.3.10.20.30.20.10.1 no-access
one day PM period threshold entry
                             per24hThresholdBoardNo 1.3.6.1.4.1.2011.2.25.3.10.20.30.20.10.1.1 gauge32 read-only
Card No.:between 1 and 20
                             per24hThresholdOpticalPort 1.3.6.1.4.1.2011.2.25.3.10.20.30.20.10.1.2 gauge32 read-only
Optical port No.:values depend on type of card
                             per24hThresholdPathNumber 1.3.6.1.4.1.2011.2.25.3.10.20.30.20.10.1.3 gauge32 read-only
Path No.:values depend on type of card
                             per24hThresholdEventID 1.3.6.1.4.1.2011.2.25.3.10.20.30.20.10.1.4 sdhperformanceeventtype read-only
Event ID:values depend on type of card
                             per24hThresholdValue 1.3.6.1.4.1.2011.2.25.3.10.20.30.20.10.1.5 gauge32 read-write
Threshold value: all parameters have only one threshold value for one day PM period.
                             per24hThresholdReset 1.3.6.1.4.1.2011.2.25.3.10.20.30.20.10.1.6 integer read-write
Threshold reset: reset threshold. Enumeration: 'reset': 1.
       perStatus 1.3.6.1.4.1.2011.2.25.3.10.20.40
             perStatusControl 1.3.6.1.4.1.2011.2.25.3.10.20.40.10
                   per15mStatusControl 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10
                         per15mMonitorStatusTable 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.10 no-access
15 minutes PM period monitor status table.
                               per15mMonitorStatusEntry 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.10.1 no-access
15 minutes PM period monitor status entry.
                                   per15mMonitorStatusBoardNo 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.10.1.1 gauge32 read-only
Card No.:between 1 and 20
                                   per15mMonitorStatusOpticalPort 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.10.1.2 gauge32 read-only
Optical port No.:values depend on type of card
                                   per15mMonitorStatusPathNumber 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.10.1.3 gauge32 read-only
Path No.:values depend on type of card
                                   per15mMonitorStatusEventID 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.10.1.4 sdhperformanceeventtype read-only
Event ID:values depend on type of card
                                   per15mMonitorStatus 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.10.1.5 integer read-write
Monitor status: when monitor status is disabled,current data register is reset to zero and will not increase any more until monitor status be enabled. The default monitor status is enable. Enumeration: 'enable': 1, 'disable': 0.
                         per15mPauseStatusTable 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.20 no-access
15 minutes PM period pause status table.
                               per15mPauseStatusEntry 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.20.1 no-access
15 minutes PM period pause status entry.
                                   per15mPauseStatusBoardNo 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.20.1.1 gauge32 read-only
Card No.:between 1 and 20
                                   per15mPauseStatusOpticalPort 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.20.1.2 gauge32 read-only
Optical port No.:values depend on type of card
                                   per15mPauseStatusPathNumber 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.20.1.3 gauge32 read-only
Path No.:values depend on type of card
                                   per15mPauseStatusEventID 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.20.1.4 sdhperformanceeventtype read-only
Event ID:values depend on type of card
                                   per15mPauseStatus 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.20.1.5 integer read-write
Pause status: when pause status is disabled,current data register will not increase (but will reset to zero)any more until pause status be enabled.The default monitor status is disable. Enumeration: 'enable': 1, 'disable': 0.
                         per15mThresholdStatusTable 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.30 no-access
15 minutes PM period threshold status table
                               per15mThresholdStatusEntry 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.30.1 no-access
15 minutes PM period threshold status entry
                                   per15mThresholdStatusBoardNo 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.30.1.1 gauge32 read-only
Card No.:between 1 and 20
                                   per15mThresholdStatusOpticalPort 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.30.1.2 gauge32 read-only
Optical port No.:values depend on type of card
                                   per15mThresholdStatusPathNumber 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.30.1.3 gauge32 read-only
Path No.:values depend on type of card
                                   per15mThresholdStatusEventID 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.30.1.4 sdhperformanceeventtype read-only
Event ID:values depend on type of card
                                   per15mThresholdStatus 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.30.1.5 integer read-write
Threshold status:when threshold status is disabled,no threshold crossing alert will be reported even though threshold is crossed.The default threshold status is enable. Enumeration: 'enable': 1, 'disable': 0.
                         per15mAutoReportStatusTable 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.40 no-access
15 minutes PM period automatic report(REP) status table
                               per15mAutoReportStatusEntry 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.40.1 no-access
15 minutes PM period automatic report(REP) status entry
                                   per15mAutoReportStatusBoardNo 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.40.1.1 gauge32 read-only
Card No.:between 1 and 20
                                   per15mAutoReportStatusOpticalPort 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.40.1.2 gauge32 read-only
Optical port No.:values depend on type of card
                                   per15mAutoReportStatusPathNumber 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.40.1.3 gauge32 read-only
Path No.:values depend on type of card
                                   per15mAutoReportStatusEventID 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.40.1.4 sdhperformanceeventtype read-only
Event ID:values depend on type of card
                                   per15mAutoReportStatus 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.40.1.5 integer read-write
Automatic report status: if automatic report status is enabled, when PM period expired, NE will report none-zero current data register value to user.The default automatic report status is enable . Enumeration: 'enable': 1, 'disable': 0.
                   per24hStatusControl 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20
                         per24hMonitorStatusTable 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.10 no-access
one day PM period monitor status table.
                               per24hMonitorStatusEntry 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.10.1 no-access
one day PM period monitor status entry.
                                   per24hMonitorStatusBoardNo 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.10.1.1 gauge32 read-only
Card No.:between 1 and 20
                                   per24hMonitorStatusOpticalPort 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.10.1.2 gauge32 read-only
Optical port No.:values depend on type of card
                                   per24hMonitorStatusPathNumber 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.10.1.3 gauge32 read-only
Path No.:values depend on type of card
                                   per24hMonitorStatusEventID 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.10.1.4 sdhperformanceeventtype read-only
Event ID:values depend on type of card
                                   per24hMonitorStatus 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.10.1.5 integer read-write
Monitor status: when monitor status is disabled,current data register is reset to zero and will not increase any more until monitor status be enabled.The default monitor status is enable. Enumeration: 'enable': 1, 'disable': 0.
                         per24hPauseStatusTable 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.20 no-access
one day PM period pause status table.
                               per24hPauseStatusEntry 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.20.1 no-access
one day PM period pause status entry.
                                   per24hPauseStatusBoardNo 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.20.1.1 gauge32 read-only
Card No.:between 1 and 20
                                   per24hPauseStatusOpticalPort 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.20.1.2 gauge32 read-only
Optical port No.:values depend on type of card
                                   per24hPauseStatusPathNumber 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.20.1.3 gauge32 read-only
Path No.:values depend on type of card
                                   per24hPauseStatusEventID 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.20.1.4 sdhperformanceeventtype read-only
Event ID:values depend on type of card
                                   per24hPauseStatus 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.20.1.5 integer read-write
Pause status: when pause status is disabled,current data register will not increase (but will reset to zero)any more until pause status be enabled.The default monitor status is disable. Enumeration: 'enable': 1, 'disable': 0.
                         per24hThresholdStatusTable 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.30 no-access
one day PM period threshold status table.
                               per24hThresholdStatusEntry 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.30.1 no-access
one day PM period threshold status entry.
                                   per24hThresholdStatusBoardNo 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.30.1.1 gauge32 read-only
Card No.:between 1 and 20
                                   per24hThresholdStatusOpticalPort 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.30.1.2 gauge32 read-only
Optical port No.:values depend on type of card
                                   per24hThresholdStatusPathNumber 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.30.1.3 gauge32 read-only
Path No.:values depend on type of card
                                   per24hThresholdStatusEventID 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.30.1.4 sdhperformanceeventtype read-only
Event ID:values depend on type of card
                                   per24hThresholdStatus 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.30.1.5 integer read-write
Threshold status:when threshold status is disabled,no threshold crossing alert will be reported even though threshold is crossed.The default threshold status is enable. Enumeration: 'enable': 1, 'disable': 0.
                         per24hAutoReportStatusTable 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.40 no-access
one day PM period automatic report(REP) status table.
                               per24hAutoReportStatusEntry 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.40.1 no-access
one day PM period automatic report(REP) status entry.
                                   per24hAutoReportStatusBoardNo 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.40.1.1 gauge32 read-only
Card No.:between 1 and 20
                                   per24hAutoReportStatusOpticalPort 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.40.1.2 gauge32 read-only
Optical port No.:values depend on type of card
                                   per24hAutoReportStatusPathNumber 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.40.1.3 gauge32 read-only
Path No.:values depend on type of card
                                   per24hAutoReportStatusEventID 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.40.1.4 sdhperformanceeventtype read-only
Event ID:values depend on type of card
                                   per24hAutoReportStatus 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.40.1.5 integer read-write
Automatic report status: if automatic report status is enabled, when PM period expired, NE will report none-zero current data register value to user.The default automatic report status is enable . Enumeration: 'enable': 1, 'disable': 0.
             perThresholdCrossStatus 1.3.6.1.4.1.2011.2.25.3.10.20.40.20
                   per15mThresholdCrossStatusTable 1.3.6.1.4.1.2011.2.25.3.10.20.40.20.10 no-access
15 minutes PM period threshold crossing status table.
                         per15mThresholdCrossStatusEntry 1.3.6.1.4.1.2011.2.25.3.10.20.40.20.10.1 no-access
15 minutes PM period threshold crossing status entry.
                             per15mThresholdCrossStatusBoardNo 1.3.6.1.4.1.2011.2.25.3.10.20.40.20.10.1.1 gauge32 read-only
Card No.:between 1 and 20
                             per15mThresholdCrossStatusOpticalPort 1.3.6.1.4.1.2011.2.25.3.10.20.40.20.10.1.2 gauge32 read-only
Optical port No.:values depend on type of card
                             per15mThresholdCrossStatusPathNumber 1.3.6.1.4.1.2011.2.25.3.10.20.40.20.10.1.3 gauge32 read-only
Path No.:values depend on type of card
                             per15mThresholdCrossStatusEventID 1.3.6.1.4.1.2011.2.25.3.10.20.40.20.10.1.4 sdhperformanceeventtype read-only
Event ID:values depend on type of card
                             per15mThresholdCrossStatus 1.3.6.1.4.1.2011.2.25.3.10.20.40.20.10.1.5 integer read-only
Threshold crossing status:normal-threshold was not crossed,crossed -threshold was crossed. Enumeration: 'crossed': 1, 'normal': 0.
                   per24hThresholdCrossStatusTable 1.3.6.1.4.1.2011.2.25.3.10.20.40.20.20 no-access
one day PM period threshold crossing status table.
                         per24hThresholdCrossStatusEntry 1.3.6.1.4.1.2011.2.25.3.10.20.40.20.20.1 no-access
one day PM period threshold crossing status entry.
                             per24hThresholdCrossStatusBoardNo 1.3.6.1.4.1.2011.2.25.3.10.20.40.20.20.1.1 gauge32 read-only
Card No.:between 1 and 20
                             per24hThresholdCrossStatusOpticalPort 1.3.6.1.4.1.2011.2.25.3.10.20.40.20.20.1.2 gauge32 read-only
Optical port No.:values depend on type of card
                             per24hThresholdCrossStatusPathNumber 1.3.6.1.4.1.2011.2.25.3.10.20.40.20.20.1.3 gauge32 read-only
Path No.:values depend on type of card
                             per24hThresholdCrossStatusEventID 1.3.6.1.4.1.2011.2.25.3.10.20.40.20.20.1.4 sdhperformanceeventtype read-only
Event ID:values depend on type of card
                             per24hThresholdCrossStatus 1.3.6.1.4.1.2011.2.25.3.10.20.40.20.20.1.5 integer read-only
Threshold crossing status:normal-threshold was not crossed,crossed -threshold was crossed. Enumeration: 'crossed': 1, 'normal': 0.
       perEvents 1.3.6.1.4.1.2011.2.25.3.10.20.50
             perUATEvent 1.3.6.1.4.1.2011.2.25.3.10.20.50.10
                   perUATEventTable 1.3.6.1.4.1.2011.2.25.3.10.20.50.10.10 no-access
UAT event table.
                         perUATEventEntry 1.3.6.1.4.1.2011.2.25.3.10.20.50.10.10.1 no-access
UAT event entry.
                             perUATBoardNo 1.3.6.1.4.1.2011.2.25.3.10.20.50.10.10.1.1 gauge32 read-only
Card No.:between 1 and 20
                             perUATOpticalPort 1.3.6.1.4.1.2011.2.25.3.10.20.50.10.10.1.2 gauge32 read-only
Optical port No.:values depend on type of card
                             perUATPathNumber 1.3.6.1.4.1.2011.2.25.3.10.20.50.10.10.1.3 gauge32 read-only
Path No.:values depend on type of card
                             perUATEventID 1.3.6.1.4.1.2011.2.25.3.10.20.50.10.10.1.4 sdhperformanceeventtype read-only
Event ID:values depend on type of card
                             perUATStartTime 1.3.6.1.4.1.2011.2.25.3.10.20.50.10.10.1.5 dateandtime read-only
the date and time when enter UAT.
                             perUATEndTime 1.3.6.1.4.1.2011.2.25.3.10.20.50.10.10.1.6 dateandtime read-only
the date and time when exit UAT.
             perCSESEvent 1.3.6.1.4.1.2011.2.25.3.10.20.50.20
                   perCSESEventTable 1.3.6.1.4.1.2011.2.25.3.10.20.50.20.10 no-access
CSES event table.
                         perCSESEventEntry 1.3.6.1.4.1.2011.2.25.3.10.20.50.20.10.1 no-access
CSES event entry.
                             perCSESBoardNo 1.3.6.1.4.1.2011.2.25.3.10.20.50.20.10.1.1 gauge32 read-only
Card No.:between 1 and 20
                             perCSESOpticalPort 1.3.6.1.4.1.2011.2.25.3.10.20.50.20.10.1.2 gauge32 read-only
Optical port No.:values depend on type of card
                             perCSESPathNumber 1.3.6.1.4.1.2011.2.25.3.10.20.50.20.10.1.3 gauge32 read-only
Path No.:values depend on type of card
                             perCSESEventID 1.3.6.1.4.1.2011.2.25.3.10.20.50.20.10.1.4 sdhperformanceeventtype read-only
Event ID:values depend on type of card
                             perCSESStartTime 1.3.6.1.4.1.2011.2.25.3.10.20.50.20.10.1.5 dateandtime read-only
the date and time when enter CSES.
                             perCSESKeepTime 1.3.6.1.4.1.2011.2.25.3.10.20.50.20.10.1.6 gauge32 read-only
the count of CSES continues.
       optixCommonSdhConformance 1.3.6.1.4.1.2011.2.25.3.10.20.90
             optixCommonSdhGroups 1.3.6.1.4.1.2011.2.25.3.10.20.90.1
                 currentObjectGroup 1.3.6.1.4.1.2011.2.25.3.10.20.90.1.1
Enter the description of the created OBJECT-GROUP.
             optixCommonSdhCompliances 1.3.6.1.4.1.2011.2.25.3.10.20.90.2
                 optixCommonSdhbasicCompliance 1.3.6.1.4.1.2011.2.25.3.10.20.90.2.1
Enter the description of the created MODULE-COMPLIANCE.