Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 oacOamMIBModule 1.3.6.1.4.1.13191.1.100.673
Contact updated
       oacAtmOamStatObjects 1.3.6.1.4.1.13191.10.3.2.2.1
           oacAtmOamStatSwitch 1.3.6.1.4.1.13191.10.3.2.2.1.1
               oacAtmOamSwitchMaxConnections 1.3.6.1.4.1.13191.10.3.2.2.1.1.1 unsigned32 read-only
Maximum number of authorised OAM configured connections
               oacAtmOamSwitchSegLoopback 1.3.6.1.4.1.13191.10.3.2.2.1.1.2 integer read-only
Enable segment loopback on this switch Enumeration: 'enable': 1, 'disable': 2.
               oacAtmOamSwitchEndLoopback 1.3.6.1.4.1.13191.10.3.2.2.1.1.3 integer read-only
Enable end to end loopback on this switch Enumeration: 'enable': 1, 'disable': 2.
               oacAtmOamSwitchAisRdiEnable 1.3.6.1.4.1.13191.10.3.2.2.1.1.4 integer read-only
Enable Remote Defect Indication OAM cell generation if an Alarm Indication Signal OAM cell is received, or if a defect is detected on the switch Enumeration: 'enable': 1, 'disable': 2.
               oacAtmOamSwitchSegmentContinuityCheckEnable 1.3.6.1.4.1.13191.10.3.2.2.1.1.5 integer read-only
Enable Segment Loss of Continuity cells defect on the pvc. Enable generation of segment Continuity Check cells on the switch. Enumeration: 'enable': 1, 'disable': 2.
               oacAtmOamSwitchEndContinuityCheckEnable 1.3.6.1.4.1.13191.10.3.2.2.1.1.6 integer read-only
Enable End to End Loss of Continuity cells defect on the pvc. Enable generation of End to End Continuity Check cells on the switch. Enumeration: 'enable': 1, 'disable': 2.
               oacAtmOamSwitchOamCellsReceived 1.3.6.1.4.1.13191.10.3.2.2.1.1.7 counter32 read-only
Number of received OAM cells on the switch
               oacAtmOamSwitchOamCellsTransmitted 1.3.6.1.4.1.13191.10.3.2.2.1.1.8 counter32 read-only
Number of transmitted OAM cells on the switch
               oacAtmOamSwitchCurrentConnections 1.3.6.1.4.1.13191.10.3.2.2.1.1.9 unsigned32 read-only
Current number of OAM configured connections
           oacAtmOamVclTable 1.3.6.1.4.1.13191.10.3.2.2.1.2 no-access
An index into the table oacAtmOamVclTable
               oacAtmOamVclEntry 1.3.6.1.4.1.13191.10.3.2.2.1.2.1 no-access
An index into the table oacAtmOamVclTable
                   oacAtmOamVclPvcManage 1.3.6.1.4.1.13191.10.3.2.2.1.2.1.1 integer read-only
Enable OAM for Pvc management Enumeration: 'enable': 1, 'disable': 2.
                   oacAtmOamVclSegmentLoopback 1.3.6.1.4.1.13191.10.3.2.2.1.2.1.2 integer read-only
Enable segment loopback on this virtual channel Enumeration: 'enable': 1, 'disable': 2.
                   oacAtmOamVclEndLoopback 1.3.6.1.4.1.13191.10.3.2.2.1.2.1.3 integer read-only
Enable end to end loopback on this virtual channel Enumeration: 'enable': 1, 'disable': 2.
                   oacAtmOamVclAisRdiEnable 1.3.6.1.4.1.13191.10.3.2.2.1.2.1.4 integer read-only
Enable Remote Defect Indication OAM cell generation if an Alarm Indication Signal OAM cell is received, or if a defect is detected on the PVC Enumeration: 'enable': 1, 'disable': 2.
                   oacAtmOamVclSegmentContinuityCheckEnable 1.3.6.1.4.1.13191.10.3.2.2.1.2.1.5 integer read-only
Enable Segment Loss of Continuity cells detect on the PVC.Enable generation of Segment Continuity Check cells on the PVC. Enumeration: 'enable': 1, 'disable': 2.
                   oacAtmOamVclEndContinuityCheckEnable 1.3.6.1.4.1.13191.10.3.2.2.1.2.1.6 integer read-only
Enable End to End Loss of Continuity cells detect on the PVC.Enable generation of End to End Continuity Check cells on the PVC. Enumeration: 'enable': 1, 'disable': 2.
                   oacAtmOamVclLoopbackTxInterval 1.3.6.1.4.1.13191.10.3.2.2.1.2.1.7 integer32 read-only
Frequency of OAM loopback cell are generated on this virtual channel
                   oacAtmOamVclLoopbackTxRetryFrequency 1.3.6.1.4.1.13191.10.3.2.2.1.2.1.8 integer32 read-only
Frequency of OAM loopback cell are generated on this virtual channel, when a change has occured, that is to say either no reception of the last loopback cell, or reception of the last loopback cell
                   oacAtmOamVclLoopbackTxRetryUpCount 1.3.6.1.4.1.13191.10.3.2.2.1.2.1.9 integer32 read-only
Counter of consecutive received loopback cells, before vcl is considered as being up
                   oacAtmOamVclLoopbackTxRetryDownCount 1.3.6.1.4.1.13191.10.3.2.2.1.2.1.10 integer32 read-only
Counter of consecutive non received loopback cells, before vcl is considered as being down
                   oacAtmOamVclAlarmState 1.3.6.1.4.1.13191.10.3.2.2.1.2.1.11 integer32 read-only
This object indicates the current alarm status of the VCL, when error monitoring is activated on the VCL. Value indicates the different alarm states tha the VCL can take. Those alarms can be combined together. The unknown state indicates that the alarm status of this VCL cannot be determined. cc_seg_loc(1),cc_ete_loc(2), lb_seg_alarm(4),lb_ete_alarm(8), ais_alarm(16),rdi_alarm(32),other(64)
                   oacAtmOamVclAlarmStateLastChange 1.3.6.1.4.1.13191.10.3.2.2.1.2.1.12 timestamp read-only
The value of sysUpTime object at the time this VCL entered its current alarm status. If the current state was entered prior to the last re-initialization of the agent, then this object contains a zero value.
                   oacAtmOamVclAisRdiRetryDownCount 1.3.6.1.4.1.13191.10.3.2.2.1.2.1.13 integer32 read-only
Number of consecutive OAM AIS/RDI cells received. The range is 3 to 60. The default is 3.
                   oacAtmOamVclAisRdiRetryUpTimer 1.3.6.1.4.1.13191.10.3.2.2.1.2.1.14 integer32 read-only
Number of seconds with no OAM AIS/RDI cells received. The range is 3 to 60 seconds . The default is 3 seconds.
                   oacAtmOamVclPvcIntrusive 1.3.6.1.4.1.13191.10.3.2.2.1.2.1.15 integer read-only
Enable OAM Intrusivity against Pvc Enumeration: 'enable': 1, 'disable': 2.
           oacAtmOamVclCountersTable 1.3.6.1.4.1.13191.10.3.2.2.1.3 no-access
An index into table oacAtmOamVclCountersTable
               oacAtmOamVclCountersEntry 1.3.6.1.4.1.13191.10.3.2.2.1.3.1 no-access
An index into table oacAtmOamVclCountersTable
                   oacAtmOamVclOamCellsReceived 1.3.6.1.4.1.13191.10.3.2.2.1.3.1.1 counter32 read-only
Number of received oam cells
                   oacAtmOamVclEndLoopbackIn 1.3.6.1.4.1.13191.10.3.2.2.1.3.1.2 counter32 read-only
Number of received non looped end to end oam loopback cells
                   oacAtmOamVclSegLoopbackIn 1.3.6.1.4.1.13191.10.3.2.2.1.3.1.3 counter32 read-only
Number of received non looped segment oam loopback cells
                   oacAtmOamVclEndLoopIn 1.3.6.1.4.1.13191.10.3.2.2.1.3.1.4 counter32 read-only
Number of received looped end to end oam loopback cells
                   oacAtmOamVclSegLoopIn 1.3.6.1.4.1.13191.10.3.2.2.1.3.1.5 counter32 read-only
Number of received looped segment oam loopback cells
                   oacAtmOamVclAisIn 1.3.6.1.4.1.13191.10.3.2.2.1.3.1.6 counter32 read-only
Number of received oam ais cells
                   oacAtmOamVclRdiIn 1.3.6.1.4.1.13191.10.3.2.2.1.3.1.7 counter32 read-only
Number of received oam rdi cells
                   oacAtmOamVclSegCCIn 1.3.6.1.4.1.13191.10.3.2.2.1.3.1.8 counter32 read-only
Number of received oam end to end continuity check cells
                   oacAtmOamVclEndCCIn 1.3.6.1.4.1.13191.10.3.2.2.1.3.1.9 counter32 read-only
Number of received oam segment continuity check cells
                   oacAtmOamVclOamCellsSent 1.3.6.1.4.1.13191.10.3.2.2.1.3.1.10 counter32 read-only
Number of sent oam cells
                   oacAtmOamVclEndLoopbackOut 1.3.6.1.4.1.13191.10.3.2.2.1.3.1.11 counter32 read-only
Number of sent non looped end to end oam loopback cells
                   oacAtmOamVclSegLoopbackOut 1.3.6.1.4.1.13191.10.3.2.2.1.3.1.12 counter32 read-only
Number of sent non looped segment oam loopback cells
                   oacAtmOamVclEndLoopOut 1.3.6.1.4.1.13191.10.3.2.2.1.3.1.13 counter32 read-only
Number of sent looped end to end oam loopback cells
                   oacAtmOamVclSegLoopOut 1.3.6.1.4.1.13191.10.3.2.2.1.3.1.14 counter32 read-only
Number of sent looped segment oam loopback cells
                   oacAtmOamVclAisOut 1.3.6.1.4.1.13191.10.3.2.2.1.3.1.15 counter32 read-only
Number of sent oam ais cells
                   oacAtmOamVclRdiOut 1.3.6.1.4.1.13191.10.3.2.2.1.3.1.16 counter32 read-only
Number of sent oam rdi cells
                   oacAtmOamVclSegCCOut 1.3.6.1.4.1.13191.10.3.2.2.1.3.1.17 counter32 read-only
Number of sent oam end to end continuity check cells
                   oacAtmOamVclEndCCOut 1.3.6.1.4.1.13191.10.3.2.2.1.3.1.18 counter32 read-only
Number of sent oam segment continuity check cells
                   oacAtmOamVclOamCellsDropped 1.3.6.1.4.1.13191.10.3.2.2.1.3.1.19 counter32 read-only
Number of received oam cells that are ignored and dropped
       oacAtmOamStatNotifications 1.3.6.1.4.1.13191.10.3.2.2.2
       oacAtmOamStatConformance 1.3.6.1.4.1.13191.10.3.2.2.3
           oacAtmOamStatGroups 1.3.6.1.4.1.13191.10.3.2.2.3.1
               oacAtmOamStatGeneralGroup 1.3.6.1.4.1.13191.10.3.2.2.3.1.1
This group is mandatory for all OAM entities.
           oacAtmOamStatCompliances 1.3.6.1.4.1.13191.10.3.2.2.3.2
               oacAtmOamStatCompliance 1.3.6.1.4.1.13191.10.3.2.2.3.2.1
The compliance statement for agents that support the ONEACCESS-OAM-MIB.