Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 oacMiscConfigMIB 1.3.6.1.4.1.13191.1.100.2003
Fixed the issues related to octet string range
   oacMiscConfig 1.3.6.1.4.1.13191.10.3.4.21
         oacTelnetServerConfigObjects 1.3.6.1.4.1.13191.10.3.4.21.1
             oacTelnetServerBindInterfaceTable 1.3.6.1.4.1.13191.10.3.4.21.1.1 no-access
This is for displaying all the users who are logged into device.
                 oacTelnetServerBindInterfaceEntry 1.3.6.1.4.1.13191.10.3.4.21.1.1.1 no-access
Each entry in the table is identified by the unique session id.
                     oacTelnetServerBindInterfaceIndex 1.3.6.1.4.1.13191.10.3.4.21.1.1.1.1 interfaceindex read-only
The interface index to which the Telnet server will bind.
                     oacTelnetServerBindInterfaceName 1.3.6.1.4.1.13191.10.3.4.21.1.1.1.2 octet string read-only
The name of the interface to which the telnet server will bind.
                     oacTelnetServerBindInterfaceRowStatus 1.3.6.1.4.1.13191.10.3.4.21.1.1.1.3 rowstatus read-only
Row status for this entry
             oacTelnetServerBindAcl 1.3.6.1.4.1.13191.10.3.4.21.1.2 octet string read-write
It is possible to restrict access to telnet clients by using a list of addresses standing for the list of permitted source IP addresses.
             oacTelnetServerIdleTimeout 1.3.6.1.4.1.13191.10.3.4.21.1.3 unsigned32 read-write
If a connected telnet client is inactive during a certain time, it is disconnected. By default, any inactive telnet client is disconnected after 10 minutes.
             oacTelnetServerLogEnable 1.3.6.1.4.1.13191.10.3.4.21.1.4 truthvalue read-write
Remote connections to the telnet server can be logged by enabling log enable.
             oacTelnetServerLogFileSize 1.3.6.1.4.1.13191.10.3.4.21.1.5 integer read-write
By default, the log file size is 8200 bytes.
         oacSyslogServerConfigObjects 1.3.6.1.4.1.13191.10.3.4.21.2
             oacSyslogServerTable 1.3.6.1.4.1.13191.10.3.4.21.2.1 no-access
Table to configure remote syslog servers.
                 oacSyslogServerEntry 1.3.6.1.4.1.13191.10.3.4.21.2.1.1 no-access
An entry for a syslog server.
                     oacSyslogServerAddress 1.3.6.1.4.1.13191.10.3.4.21.2.1.1.1 octet string read-only
The remote syslog server IP address, or hostname.
                     oacSyslogServerFacilityNum 1.3.6.1.4.1.13191.10.3.4.21.2.1.1.2 integer read-only
facility number, ranging from 0 up to 23. Must be set according to the server configuration
                     oacSyslogServerInterface 1.3.6.1.4.1.13191.10.3.4.21.2.1.1.3 interfaceindex read-only
The interface which this syslog client should used to send log messages to the configured remote syslog server.
                     oacSyslogServerRowStatus 1.3.6.1.4.1.13191.10.3.4.21.2.1.1.4 rowstatus read-only
Row status for this entry
             oacSyslogMaxServers 1.3.6.1.4.1.13191.10.3.4.21.2.2 integer read-write
maximum number of syslog servers that can be configured.
         oacSntpClientConfigObjects 1.3.6.1.4.1.13191.10.3.4.21.3
             oacSntpClientBroadcastEnable 1.3.6.1.4.1.13191.10.3.4.21.3.1 truthvalue read-write
To configure the SNTP client in broadcast mode to accept NTP packets from any NTP broadcast server.
             oacSntpRemoteServerTable 1.3.6.1.4.1.13191.10.3.4.21.3.2 no-access
Table to configure the SNTP client to request NTP packets from a specified NTP server
                 oacSntpRemoteServerEntry 1.3.6.1.4.1.13191.10.3.4.21.3.2.1 no-access
Entry for the remote sntp server.
                     oacSntpRemoteServerAddress 1.3.6.1.4.1.13191.10.3.4.21.3.2.1.1 octet string read-only
The sntp remote server info.
                     oacSntpRemoteServerInterface 1.3.6.1.4.1.13191.10.3.4.21.3.2.1.2 interfaceindex read-only
Interface thru which the client requests the ntp servers.
                     oacSntpRemoteServerRowStatus 1.3.6.1.4.1.13191.10.3.4.21.3.2.1.3 rowstatus read-only
Row status for this entry
             oacSntpClientPollInterval 1.3.6.1.4.1.13191.10.3.4.21.3.3 unsigned32 read-write
The duration between two requests sent to the NTP server when synchronized.
         oacBannerConfigObjects 1.3.6.1.4.1.13191.10.3.4.21.4
             oacConfigBannerSeqTable 1.3.6.1.4.1.13191.10.3.4.21.4.1 no-access
This table holds upto 40 banner messages.
                 oacConfigBannerSeqEntry 1.3.6.1.4.1.13191.10.3.4.21.4.1.1 no-access
Each entry will hold one banner string
                     oacConfigBannerType 1.3.6.1.4.1.13191.10.3.4.21.4.1.1.1 integer read-only
motd is for the text displayed when attempting to log in, whereas exec is for the text displayed when logged in. Enumeration: 'motd': 1, 'exec': 2.
                     oacConfigBannerSequence 1.3.6.1.4.1.13191.10.3.4.21.4.1.1.2 integer read-only
The maximum number of strings that can be stored are 40.
                     oacConfigBannerString 1.3.6.1.4.1.13191.10.3.4.21.4.1.1.3 octet string read-only
banner test is a set of string maximum upto 255 characters.
                     oacConfigBannerSeqRowStatus 1.3.6.1.4.1.13191.10.3.4.21.4.1.1.4 rowstatus read-only
The row status of this entry
             oacConfigMotdBanner 1.3.6.1.4.1.13191.10.3.4.21.4.2 octet string read-write
banner text without a sequence number displayed when attempting to login.
             oacConfigExecBanner 1.3.6.1.4.1.13191.10.3.4.21.4.3 octet string read-write
banner text without a sequence number displayed when logged in.
         oacDateAndTimeConfigObjects 1.3.6.1.4.1.13191.10.3.4.21.5
             oacMiscConfigDateAndTime 1.3.6.1.4.1.13191.10.3.4.21.5.1 dateandtime read-write
Current date and time
             oacConfigClockDstTable 1.3.6.1.4.1.13191.10.3.4.21.5.2 no-access
Entry for day light saving this table
                 oacConfigClockDstEntry 1.3.6.1.4.1.13191.10.3.4.21.5.2.1 no-access
Entry for this table.
                     oacClockDstName 1.3.6.1.4.1.13191.10.3.4.21.5.2.1.1 octet string read-only
oacClockDstName is an arbitrary string that can ease readability.
                     oacClockDstSummerStartWeek 1.3.6.1.4.1.13191.10.3.4.21.5.2.1.2 octet string read-only
designates the week when the summer time starts
                     oacClockDstSummerStartDate 1.3.6.1.4.1.13191.10.3.4.21.5.2.1.3 octet string read-only
Summer day light saving start date
                     oacClockDstWinterStartWeek 1.3.6.1.4.1.13191.10.3.4.21.5.2.1.4 octet string read-only
designates the week when the winter time starts
                     oacClockDstWinterStartDate 1.3.6.1.4.1.13191.10.3.4.21.5.2.1.5 octet string read-only
Winter day light saving start time.
                     oacClockDstRowStatus 1.3.6.1.4.1.13191.10.3.4.21.5.2.1.6 rowstatus read-only
RowStatus for this entry.
         oacMiscConfigConformance 1.3.6.1.4.1.13191.10.3.4.21.6
             oacMiscConfigGroups 1.3.6.1.4.1.13191.10.3.4.21.6.1
                 oacMiscConfigGroup 1.3.6.1.4.1.13191.10.3.4.21.6.1.1
Group of Misc Configuration objects.
             oacMiscCompls 1.3.6.1.4.1.13191.10.3.4.21.6.2