Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 gx2Rsw1000bDescriptor 1.3.6.1.4.1.1166.6.1.2.18.1
 gx2Rsw1000bAnalogTable 1.3.6.1.4.1.1166.6.1.2.18.2 no-access
This table contains gx2Rsw1000b specific parameters with nominal and current values.
     gx2Rsw1000bAnalogEntry 1.3.6.1.4.1.1166.6.1.2.18.2.1 no-access
This list contains the analog parameters and descriptions.
         gx2Rsw1000bAnalogTableIndex 1.3.6.1.4.1.1166.6.1.2.18.2.1.1 integer read-only
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
         rsw1000blabelPriRFInputLvl 1.3.6.1.4.1.1166.6.1.2.18.2.1.2 displaystring read-only
The value of this object provides the label of the Primary RF Input Level Analog parameter.
         rsw1000buomPriRFInputLvl 1.3.6.1.4.1.1166.6.1.2.18.2.1.3 displaystring read-only
The value of this object provides the Unit of Measure of the Primary RF Input Level Analog parameter. For all analog objects for this parameter type, the Unit of Measure is dBmV.
         rsw1000bmajorHighPriRFInputLvl 1.3.6.1.4.1.1166.6.1.2.18.2.1.4 float read-only
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Major High alarm value of the Primary RF Input Level Analog parameter.
         rsw1000bmajorLowPriRFInputLvl 1.3.6.1.4.1.1166.6.1.2.18.2.1.5 float read-only
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Major Low alarm value of the Primary RF Input Level Analog parameter.
         rsw1000bminorHighPriRFInputLvl 1.3.6.1.4.1.1166.6.1.2.18.2.1.6 float read-only
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Minor High alarm value of the Primary RF Input Level Analog parameter.
         rsw1000bminorLowPriRFInputLvl 1.3.6.1.4.1.1166.6.1.2.18.2.1.7 float read-only
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Minor Low alarm value of the Primary RF Input Level Analog parameter.
         rsw1000bcurrentValuePriRFInputLvl 1.3.6.1.4.1.1166.6.1.2.18.2.1.8 float read-only
The value of this object provides the current value of the Primary RF Input Level Analog parameter.
         rsw1000bstateFlagPriRFInputLvl 1.3.6.1.4.1.1166.6.1.2.18.2.1.9 integer read-only
The value of this object provides the state of the Primary RF Input Level Analog parameter. (1-hidden 2-read-only, 3-updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
         rsw1000bminValuePriRFInputLvl 1.3.6.1.4.1.1166.6.1.2.18.2.1.10 float read-only
The value of this object represents a gauge minimum limit for the Primary RF Input Level Analog parameter.
         rsw1000bmaxValuePriRFInputLvl 1.3.6.1.4.1.1166.6.1.2.18.2.1.11 float read-only
The value of this object represents a gauge maximum limit for the Primary RF Input Level Analog parameter.
         rsw1000balarmStatePriRFInputLvl 1.3.6.1.4.1.1166.6.1.2.18.2.1.12 integer read-only
The value of this object provides the curent alarm state of the Primary RF Input Level Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6.
         rsw1000blabelSecRFInputLvl 1.3.6.1.4.1.1166.6.1.2.18.2.1.13 displaystring read-only
The value of this object provides the label of the Secondary RF Input Level Analog parameter.
         rsw1000buomSecRFInputLvl 1.3.6.1.4.1.1166.6.1.2.18.2.1.14 displaystring read-only
The value of this object provides the Unit of Measure of the Secondary RF Input Level Analog parameter. For all analog objects for this parameter type, the Unit of Measure is dBmV.
         rsw1000bmajorHighSecRFInputLvl 1.3.6.1.4.1.1166.6.1.2.18.2.1.15 float read-only
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Major High alarm value of the Secondary RF Input Level Analog parameter.
         rsw1000bmajorLowSecRFInputLvl 1.3.6.1.4.1.1166.6.1.2.18.2.1.16 float read-only
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Major Low alarm value of the Secondary RF Input Level Analog parameter.
         rsw1000bminorHighSecRFInputLvl 1.3.6.1.4.1.1166.6.1.2.18.2.1.17 float read-only
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Minor High alarm value of the Secondary RF Input Level Analog parameter.
         rsw1000bminorLowSecRFInputLvl 1.3.6.1.4.1.1166.6.1.2.18.2.1.18 float read-only
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Minor Low alarm value of the Secondary RF Input Level Analog parameter.
         rsw1000bcurrentValueSecRFInputLvl 1.3.6.1.4.1.1166.6.1.2.18.2.1.19 float read-only
The value of this object provides the current value of the Secondary RF Input Level Analog parameter.
         rsw1000bstateFlagSecRFInputLvl 1.3.6.1.4.1.1166.6.1.2.18.2.1.20 integer read-only
The value of this object provides the state of the Secondary RF Input Level Analog parameter. (1-hidden 2-read-only, 3-updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
         rsw1000bminValueSecRFInputLvl 1.3.6.1.4.1.1166.6.1.2.18.2.1.21 float read-only
The value of this object represents a gauge minimum limit for the Secondary RF Input Level Analog parameter.
         rsw1000bmaxValueSecRFInputLvl 1.3.6.1.4.1.1166.6.1.2.18.2.1.22 float read-only
The value of this object represents a gauge maximum limit for the Secondary RF Input Level Analog parameter.
         rsw1000balarmStateSecRFInputLvl 1.3.6.1.4.1.1166.6.1.2.18.2.1.23 integer read-only
The value of this object provides the curent alarm state of the Secondary RF Input Level Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6.
         rsw1000blabelPriRFThreshold 1.3.6.1.4.1.1166.6.1.2.18.2.1.24 displaystring read-only
The value of this object provides the label of the Primary RF Threshold Analog parameter.
         rsw1000buomPriRFThreshold 1.3.6.1.4.1.1166.6.1.2.18.2.1.25 displaystring read-only
The value of this object provides the Unit of Measure of the Primary RF Threshold Analog parameter. For all analog objects for this parameter type, the Unit of Measure is dBmV.
         rsw1000bmajorHighPriRFThreshold 1.3.6.1.4.1.1166.6.1.2.18.2.1.26 float read-only
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Major High alarm value of the Primary RF Threshold Analog parameter.
         rsw1000bmajorLowPriRFThreshold 1.3.6.1.4.1.1166.6.1.2.18.2.1.27 float read-only
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Major Low alarm value of the Primary RF Threshold Analog parameter.
         rsw1000bminorHighPriRFThreshold 1.3.6.1.4.1.1166.6.1.2.18.2.1.28 float read-only
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Minor High alarm value of the Primary RF Threshold Analog parameter.
         rsw1000bminorLowPriRFThreshold 1.3.6.1.4.1.1166.6.1.2.18.2.1.29 float read-only
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Minor Low alarm value of the Primary RF Threshold Analog parameter.
         rsw1000bcurrentValuePriRFThreshold 1.3.6.1.4.1.1166.6.1.2.18.2.1.30 float read-write
The value of this object provides the current value of the Primary RF Threshold Analog parameter.
         rsw1000bstateFlagPriRFThreshold 1.3.6.1.4.1.1166.6.1.2.18.2.1.31 integer read-only
The value of this object provides the state of the Primary RF Threshold Analog parameter. (1-hidden 2-read-only, 3-updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
         rsw1000bminValuePriRFThreshold 1.3.6.1.4.1.1166.6.1.2.18.2.1.32 float read-only
The value of this object represents a gauge minimum limit for the Primary RF Threshold Analog parameter.
         rsw1000bmaxValuePriRFThreshold 1.3.6.1.4.1.1166.6.1.2.18.2.1.33 float read-only
The value of this object represents a gauge maximum limit for the Primary RF Threshold Analog parameter.
         rsw1000balarmStatePriRFThreshold 1.3.6.1.4.1.1166.6.1.2.18.2.1.34 integer read-only
The value of this object provides the curent alarm state of the Primary RF Threshold Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6.
         rsw1000blabelSecRFThreshold 1.3.6.1.4.1.1166.6.1.2.18.2.1.35 displaystring read-only
The value of this object provides the label of the Secondary RF Threshold Analog parameter.
         rsw1000buomSecRFThreshold 1.3.6.1.4.1.1166.6.1.2.18.2.1.36 displaystring read-only
The value of this object provides the Unit of Measure of the Secondary RF Threshold Analog parameter. For all analog objects for this parameter type, the Unit of Measure is dBmV.
         rsw1000bmajorHighSecRFThreshold 1.3.6.1.4.1.1166.6.1.2.18.2.1.37 float read-only
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Major High alarm value of the Secondary RF Threshold Analog parameter.
         rsw1000bmajorLowSecRFThreshold 1.3.6.1.4.1.1166.6.1.2.18.2.1.38 float read-only
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Major Low alarm value of the Secondary RF Threshold Analog parameter.
         rsw1000bminorHighSecRFThreshold 1.3.6.1.4.1.1166.6.1.2.18.2.1.39 float read-only
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Minor High alarm value of the Secondary RF Threshold Analog parameter.
         rsw1000bminorLowSecRFThreshold 1.3.6.1.4.1.1166.6.1.2.18.2.1.40 float read-only
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Minor Low alarm value of the Secondary RF Threshold Analog parameter.
         rsw1000bcurrentValueSecRFThreshold 1.3.6.1.4.1.1166.6.1.2.18.2.1.41 float read-write
The value of this object provides the current value of the Secondary RF Threshold Analog parameter.
         rsw1000bstateFlagSecRFThreshold 1.3.6.1.4.1.1166.6.1.2.18.2.1.42 integer read-only
The value of this object provides the state of the Secondary RF Threshold Analog parameter. (1-hidden 2-read-only, 3-updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
         rsw1000bminValueSecRFThreshold 1.3.6.1.4.1.1166.6.1.2.18.2.1.43 float read-only
The value of this object represents a gauge minimum limit for the Secondary RF Threshold Analog parameter.
         rsw1000bmaxValueSecRFThreshold 1.3.6.1.4.1.1166.6.1.2.18.2.1.44 float read-only
The value of this object represents a gauge maximum limit for the Secondary RF Threshold Analog parameter.
         rsw1000balarmStateSecRFThreshold 1.3.6.1.4.1.1166.6.1.2.18.2.1.45 integer read-only
The value of this object provides the curent alarm state of the Secondary RF Threshold Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6.
         rsw1000blabelModTemp 1.3.6.1.4.1.1166.6.1.2.18.2.1.46 displaystring read-only
The value of this object provides the label of the Module Temperature Analog parameter.
         rsw1000buomModTemp 1.3.6.1.4.1.1166.6.1.2.18.2.1.47 displaystring read-only
The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. For all analog objects for this parameter type, the Unit of Measure is degrees Celsius.
         rsw1000bmajorHighModTemp 1.3.6.1.4.1.1166.6.1.2.18.2.1.48 float read-only
The value of this object provides the Major High alarm value of the Module Temperature Analog parameter.
         rsw1000bmajorLowModTemp 1.3.6.1.4.1.1166.6.1.2.18.2.1.49 float read-only
The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter.
         rsw1000bminorHighModTemp 1.3.6.1.4.1.1166.6.1.2.18.2.1.50 float read-only
The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter.
         rsw1000bminorLowModTemp 1.3.6.1.4.1.1166.6.1.2.18.2.1.51 float read-only
The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter.
         rsw1000bcurrentValueModTemp 1.3.6.1.4.1.1166.6.1.2.18.2.1.52 float read-only
The value of this object provides the Current value of the Module Temperature Analog parameter.
         rsw1000bstateFlagModTemp 1.3.6.1.4.1.1166.6.1.2.18.2.1.53 integer read-only
The value of this object provides the state of the Module Temperature Analog parameter. (1-hidden 2-read-only, 3-updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
         rsw1000bminValueModTemp 1.3.6.1.4.1.1166.6.1.2.18.2.1.54 float read-only
The value of this object represents a gauge minimum limit for the Module Temperature Analog parameter.
         rsw1000bmaxValueModTemp 1.3.6.1.4.1.1166.6.1.2.18.2.1.55 float read-only
The value of this object represents a gauge maximum limit for the Module Temperature Analog parameter.
         rsw1000balarmStateModTemp 1.3.6.1.4.1.1166.6.1.2.18.2.1.56 integer read-only
The value of this object provides the curent alarm state of the Module Temperature Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6.
         rsw1000blabelFanCurrent 1.3.6.1.4.1.1166.6.1.2.18.2.1.57 displaystring read-only
The value of this object provides the label of the Fan Current Analog parameter.
         rsw1000buomFanCurrent 1.3.6.1.4.1.1166.6.1.2.18.2.1.58 displaystring read-only
The value of this object provides the Unit of Measure of the Fan Current Analog parameter. For all analog objects for this parameter type, the Unit of Measure is mA
         rsw1000bmajorHighFanCurrent 1.3.6.1.4.1.1166.6.1.2.18.2.1.59 float read-only
The value of this object provides the Major High alarm value of the Fan Current Analog parameter.
         rsw1000bmajorLowFanCurrent 1.3.6.1.4.1.1166.6.1.2.18.2.1.60 float read-only
The value of this object provides the Major Low alarm value of the Fan Current Analog parameter.
         rsw1000bminorHighFanCurrent 1.3.6.1.4.1.1166.6.1.2.18.2.1.61 float read-only
This object is not used by this module and always returns invalid floating point value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Minor High alarm value of the Fan Current Analog parameter.
         rsw1000bminorLowFanCurrent 1.3.6.1.4.1.1166.6.1.2.18.2.1.62 float read-only
This object is not used by this module and always returns invalid floating point value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter.
         rsw1000bcurrentValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.18.2.1.63 float read-only
The value of this object provides the Current value of the Fan Current Analog parameter.
         rsw1000bstateFlagFanCurrent 1.3.6.1.4.1.1166.6.1.2.18.2.1.64 integer read-only
The value of this object provides the state of the Fan Current Analog parameter. (1-hidden 2-read-only, 3-updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
         rsw1000bminValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.18.2.1.65 float read-only
The value of this object represents a gauge minimum limit for the Fan Current Analog parameter.
         rsw1000bmaxValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.18.2.1.66 float read-only
The value of this object represents a gauge maximum limit for the Fan Current Analog parameter.
         rsw1000balarmStateFanCurrent 1.3.6.1.4.1.1166.6.1.2.18.2.1.67 integer read-only
The value of this object provides the curent alarm state of the Fan Current Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6.
 gx2Rsw1000bDigitalTable 1.3.6.1.4.1.1166.6.1.2.18.3 no-access
This table contains gx2Rsw1000b specific parameters with nominal and current values.
     gx2Rsw1000bDigitalEntry 1.3.6.1.4.1.1166.6.1.2.18.3.2 no-access
This list contains digital parameters and descriptions.
         gx2Rsw1000bDigitalTableIndex 1.3.6.1.4.1.1166.6.1.2.18.3.2.1 integer read-only
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
         rsw1000blabelSwitchControl 1.3.6.1.4.1.1166.6.1.2.18.3.2.2 displaystring read-only
The value of this object provides the label of the Switch Control Digital parameter.
         rsw1000benumSwitchControl 1.3.6.1.4.1.1166.6.1.2.18.3.2.3 displaystring read-only
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
         rsw1000bvalueSwitchControl 1.3.6.1.4.1.1166.6.1.2.18.3.2.4 integer read-write
The value of this object is the current value of the parameter. Enumeration: 'primary': 1, 'secondary': 2.
         rsw1000bstateflagSwitchControl 1.3.6.1.4.1.1166.6.1.2.18.3.2.5 integer read-only
The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
         rsw1000blabelSwitchMode 1.3.6.1.4.1.1166.6.1.2.18.3.2.6 displaystring read-only
The value of this object provides the label of the Revert Mode Digital parameter.
         rsw1000benumSwitchMode 1.3.6.1.4.1.1166.6.1.2.18.3.2.7 displaystring read-only
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
         rsw1000bvalueSwitchMode 1.3.6.1.4.1.1166.6.1.2.18.3.2.8 integer read-write
The value of this object is the current value of the parameter. Enumeration: 'manual': 2, 'automatic': 1.
         rsw1000bstateflagSwitchMode 1.3.6.1.4.1.1166.6.1.2.18.3.2.9 integer read-only
The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
         rsw1000blabelRevertEnable 1.3.6.1.4.1.1166.6.1.2.18.3.2.10 displaystring read-only
The value of this object provides the label of the Revert Enable Digital parameter.
         rsw1000benumRevertEnable 1.3.6.1.4.1.1166.6.1.2.18.3.2.11 displaystring read-only
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
         rsw1000bvalueRevertEnable 1.3.6.1.4.1.1166.6.1.2.18.3.2.12 integer read-write
The value of this object is the current value of the parameter. Enumeration: 'on': 2, 'off': 1.
         rsw1000bstateflagRevertEnable 1.3.6.1.4.1.1166.6.1.2.18.3.2.13 integer read-only
The value of this object provides the state of the the parameter. (1-hidden 2-read-only, 3-updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
         rsw1000blabelRevertTime 1.3.6.1.4.1.1166.6.1.2.18.3.2.14 displaystring read-only
The value of this object provides the label of the Revert Time Digital parameter.
         rsw1000benumRevertTime 1.3.6.1.4.1.1166.6.1.2.18.3.2.15 displaystring read-only
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
         rsw1000bvalueRevertTime 1.3.6.1.4.1.1166.6.1.2.18.3.2.16 integer read-write
The value of this object is the current value of the parameter. Enumeration: 'sixtysec': 2, 'sixhundredsec': 3, 'tensec': 1.
         rsw1000bstateflagRevertTime 1.3.6.1.4.1.1166.6.1.2.18.3.2.17 integer read-only
The value of this object provides the state of the the parameter. (1-hidden 2-read-only, 3-updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
         rsw1000blabelSensorMode 1.3.6.1.4.1.1166.6.1.2.18.3.2.18 displaystring read-only
The value of this object provides the label of the SensorMode Digital parameter.
         rsw1000benumSensorMode 1.3.6.1.4.1.1166.6.1.2.18.3.2.19 displaystring read-only
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
         rsw1000bvalueSensorMode 1.3.6.1.4.1.1166.6.1.2.18.3.2.20 integer read-write
The value of this object is the current value of the parameter. Enumeration: 'internal': 1, 'external': 2.
         rsw1000bstateflagSensorMode 1.3.6.1.4.1.1166.6.1.2.18.3.2.21 integer read-only
The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
         rsw1000blabelSwitchMonitor 1.3.6.1.4.1.1166.6.1.2.18.3.2.22 displaystring read-only
The value of this object provides the label of the Switch Monitor Digital parameter.
         rsw1000benumSwitchMonitor 1.3.6.1.4.1.1166.6.1.2.18.3.2.23 displaystring read-only
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
         rsw1000bvalueSwitchMonitor 1.3.6.1.4.1.1166.6.1.2.18.3.2.24 integer read-only
The value of this object is the current value of the parameter. Enumeration: 'primary': 1, 'secondary': 2.
         rsw1000bstateflagSwitchMonitor 1.3.6.1.4.1.1166.6.1.2.18.3.2.25 integer read-only
The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
         rsw1000blabelPriStatusSig 1.3.6.1.4.1.1166.6.1.2.18.3.2.26 displaystring read-only
The value of this object provides the label of the Primary Control Signal Digital parameter.
         rsw1000benumPriStatusSig 1.3.6.1.4.1.1166.6.1.2.18.3.2.27 displaystring read-only
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
         rsw1000bvaluePriStatusSig 1.3.6.1.4.1.1166.6.1.2.18.3.2.28 integer read-only
The value of this object is the current value of the parameter. Enumeration: 'short': 1, 'open': 4, 'valid': 2, 'invalid': 3.
         rsw1000bstateflagPriStatusSig 1.3.6.1.4.1.1166.6.1.2.18.3.2.29 integer read-only
The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
         rsw1000blabelSecStatusSig 1.3.6.1.4.1.1166.6.1.2.18.3.2.30 displaystring read-only
The value of this object provides the label of the Secondary Control Signal Digital parameter.
         rsw1000benumSecStatusSig 1.3.6.1.4.1.1166.6.1.2.18.3.2.31 displaystring read-only
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
         rsw1000bvalueSecStatusSig 1.3.6.1.4.1.1166.6.1.2.18.3.2.32 integer read-only
The value of this object is the current value of the parameter. Enumeration: 'short': 1, 'open': 4, 'valid': 2, 'invalid': 3.
         rsw1000bstateflagSecStatusSig 1.3.6.1.4.1.1166.6.1.2.18.3.2.33 integer read-only
The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
         rsw1000blabelFactoryDefault 1.3.6.1.4.1.1166.6.1.2.18.3.2.34 displaystring read-only
The value of this object provides the label of the Factory Default Reset Digital parameter.
         rsw1000benumFactoryDefault 1.3.6.1.4.1.1166.6.1.2.18.3.2.35 displaystring read-only
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
         rsw1000bvalueFactoryDefault 1.3.6.1.4.1.1166.6.1.2.18.3.2.36 integer read-write
This is a one-shot control value. A read of this value is always the value corresponding to off(1). A write of the value corresponding to on(2) results in effecting the factory default reset. A write of the value corresponding to off(1) has no effect. Enumeration: 'on': 2, 'off': 1.
         rsw1000bstateflagFactoryDefault 1.3.6.1.4.1.1166.6.1.2.18.3.2.37 integer read-only
The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
 gx2Rsw1000bStatusTable 1.3.6.1.4.1.1166.6.1.2.18.4 no-access
This table contains gx2Rsw1000b specific parameters with nominal and current values.
     gx2Rsw1000bStatusEntry 1.3.6.1.4.1.1166.6.1.2.18.4.3 no-access
This list contains Status parameters and descriptions.
         gx2Rsw1000bStatusTableIndex 1.3.6.1.4.1.1166.6.1.2.18.4.3.1 integer read-only
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
         rsw1000blabelBoot 1.3.6.1.4.1.1166.6.1.2.18.4.3.2 displaystring read-only
The value of this object provides the label of the Boot Status Status parameter.
         rsw1000bvalueBoot 1.3.6.1.4.1.1166.6.1.2.18.4.3.3 integer read-only
The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4.
         rsw1000bstateflagBoot 1.3.6.1.4.1.1166.6.1.2.18.4.3.4 integer read-only
The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
         rsw1000blabelFlash 1.3.6.1.4.1.1166.6.1.2.18.4.3.5 displaystring read-only
The value of this object provides the label of the Flash Status Status parameter.
         rsw1000bvalueFlash 1.3.6.1.4.1.1166.6.1.2.18.4.3.6 integer read-only
The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4.
         rsw1000bstateflagFlash 1.3.6.1.4.1.1166.6.1.2.18.4.3.7 integer read-only
The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
         rsw1000blabelFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.18.4.3.8 displaystring read-only
The value of this object provides the label of the Factory Data CRC Status parameter.
         rsw1000bvalueFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.18.4.3.9 integer read-only
The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4.
         rsw1000bstateflagFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.18.4.3.10 integer read-only
The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
         rsw1000blabelRFDataCRC 1.3.6.1.4.1.1166.6.1.2.18.4.3.11 displaystring read-only
The value of this object provides the label of the Radio Frequency Data CRC Status parameter.
         rsw1000bvalueRFDataCRC 1.3.6.1.4.1.1166.6.1.2.18.4.3.12 integer read-only
The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4.
         rsw1000bstateflagRFDataCRC 1.3.6.1.4.1.1166.6.1.2.18.4.3.13 integer read-only
The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
         rsw1000blabelAlarmDataCRC 1.3.6.1.4.1.1166.6.1.2.18.4.3.14 displaystring read-only
The value of this object provides the label of the Alarm Data Crc parameter.
         rsw1000bvalueAlarmDataCRC 1.3.6.1.4.1.1166.6.1.2.18.4.3.15 integer read-only
The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4.
         rsw1000bstateflagAlarmDataCRC 1.3.6.1.4.1.1166.6.1.2.18.4.3.16 integer read-only
The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
         rsw1000blabelRFSignalStatus 1.3.6.1.4.1.1166.6.1.2.18.4.3.17 displaystring read-only
The value of this object provides the label of the RF Signal Status parameter.
         rsw1000bvalueRFSignalStatus 1.3.6.1.4.1.1166.6.1.2.18.4.3.18 integer read-only
The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4.
         rsw1000bstateflagRFSignalStatus 1.3.6.1.4.1.1166.6.1.2.18.4.3.19 integer read-only
The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
         rsw1000blabelPriActiveStatus 1.3.6.1.4.1.1166.6.1.2.18.4.3.20 displaystring read-only
The value of this object provides the label of the Secondary Active Status parameter.
         rsw1000bvaluePriActiveStatus 1.3.6.1.4.1.1166.6.1.2.18.4.3.21 integer read-only
The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4.
         rsw1000bstateflagPriActiveStatus 1.3.6.1.4.1.1166.6.1.2.18.4.3.22 integer read-only
The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
 gx2Rsw1000bFactoryTable 1.3.6.1.4.1.1166.6.1.2.18.5 no-access
This table contains gx2Rsw1000b specific parameters with nominal and current values.
     gx2Rsw1000bFactoryEntry 1.3.6.1.4.1.1166.6.1.2.18.5.4 no-access
This list contains Factory parameters and descriptions.
         gx2Rsw1000bFactoryTableIndex 1.3.6.1.4.1.1166.6.1.2.18.5.4.1 integer read-only
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
         rsw1000bbootControlByte 1.3.6.1.4.1.1166.6.1.2.18.5.4.2 integer read-only
The value of this object indicates which bank the firmware is currently being boot from.
         rsw1000bbootStatusByte 1.3.6.1.4.1.1166.6.1.2.18.5.4.3 integer read-only
This object indicates the status of the last boot
         rsw1000bbank0CRC 1.3.6.1.4.1.1166.6.1.2.18.5.4.4 integer read-only
This object provides the CRC code of bank 0.
         rsw1000bbank1CRC 1.3.6.1.4.1.1166.6.1.2.18.5.4.5 integer read-only
This object provides the CRC code of bank 1.
         rsw1000bprgEEPROMByte 1.3.6.1.4.1.1166.6.1.2.18.5.4.6 integer read-only
This object indicates if the EEPROM has been programmed
         rsw1000bfactoryCRC 1.3.6.1.4.1.1166.6.1.2.18.5.4.7 integer read-only
This object provides the CRC code for the Factory data.
         rsw1000bcalculateCRC 1.3.6.1.4.1.1166.6.1.2.18.5.4.8 integer read-only
This oject indicates which of the Emnums will have the CRC calculated. Enumeration: 'alarm': 3, 'rf': 2, 'factory': 1.
         rsw1000bhourMeter 1.3.6.1.4.1.1166.6.1.2.18.5.4.9 integer read-only
This object provides the hour meter reading of the module.
         rsw1000bflashPrgCnt0 1.3.6.1.4.1.1166.6.1.2.18.5.4.10 integer read-only
This object provides the number of times Bank 1 flash has been programmed.
         rsw1000bflashPrgCnt1 1.3.6.1.4.1.1166.6.1.2.18.5.4.11 integer read-only
This object provides the number of times Bank 1 flash has been programmed.
         rsw1000bflashBank0Rev 1.3.6.1.4.1.1166.6.1.2.18.5.4.12 displaystring read-only
This object provides the revision of flash bank 0.
         rsw1000bflashBank1Rev 1.3.6.1.4.1.1166.6.1.2.18.5.4.13 displaystring read-only
This object provides the revision of flash bank 1.
         rsw1000bSubagentRev 1.3.6.1.4.1.1166.6.1.2.18.5.4.14 displaystring read-only
This object provides the revision of the subagent.
 gx2Rsw1000bHoldTimeTable 1.3.6.1.4.1.1166.6.1.2.18.6 no-access
This table contains gx2Rsw1000b specific parameters with nominal and current values.
     gx2Rsw1000bHoldTimeEntry 1.3.6.1.4.1.1166.6.1.2.18.6.5 no-access
This list contains digital product class and the associated RF channel parameters and descriptions.
         rxgx2Rsw1000bHoldTimeTableIndex 1.3.6.1.4.1.1166.6.1.2.18.6.5.1 integer read-only
The value of this object is the index of the data object.
         rxgx2Rsw1000bHoldTimeSpecIndex 1.3.6.1.4.1.1166.6.1.2.18.6.5.2 integer read-only
The value of this object identifies the index of the alarm object to be modified.
         rxgx2Rsw1000bHoldTimeData 1.3.6.1.4.1.1166.6.1.2.18.6.5.3 integer read-write
The value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered into bytes zero and one of the object. Bytes three and four are used to entering the hold time for the specified alarm object. The Hold timer data ranges from 0 to 1300 seconds. The index of this object corresponds to the alarm object to be modified. Alarm Hold timers correspond to the index of this object as follows: Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx, The hold time is represented in seconds.
   trapRSW1000bConfigChangeInteger 1.3.6.1.4.1.1166.6.1.2.180.1
This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
   trapRSW1000bConfigChangeDisplayString 1.3.6.1.4.1.1166.6.1.2.180.2
This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
   trapRSW1000bRFInputAlarm 1.3.6.1.4.1.1166.6.1.2.180.3
This trap is issued when the Switch Control signals go out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
   trapRSW1000bFanCurrentAlarm 1.3.6.1.4.1.1166.6.1.2.180.4
This trap is issued when the Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
   trapRSW1000bModuleTempAlarm 1.3.6.1.4.1.1166.6.1.2.180.5
This trap is issued when the Temperature goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
   trapRSW1000bFlashAlarm 1.3.6.1.4.1.1166.6.1.2.180.6
This trap is issued when the detects an error during Flash memory operations.
   trapRSW1000bBankBootAlarm 1.3.6.1.4.1.1166.6.1.2.180.7
This trap is issued when the detects an error while booting from bank 0 or bank 1.
   trapRSW1000bAlarmDataCRCAlarm 1.3.6.1.4.1.1166.6.1.2.180.8
This trap is issued when the Alarm Data CRC is incorrect.
   trapRSW1000bFactoryDataCRCAlarm 1.3.6.1.4.1.1166.6.1.2.180.9
This trap is issued when the Factory Data CRC is incorrect.
   trapRSW1000bInputSwitchedAlarm 1.3.6.1.4.1.1166.6.1.2.180.10
This trap is issued when the RF input switched.
   trapRSW1000bResetFactoryDefaultAlarm 1.3.6.1.4.1.1166.6.1.2.180.11
This trap is issued when the Factory Default Reset occurs.
   trapRSW1000bSecondaryInputActiveAlarm 1.3.6.1.4.1.1166.6.1.2.180.12
This trap is issued when the scondary input becomes active.
   trapRSW1000bCalibrationDataCRCAlarm 1.3.6.1.4.1.1166.6.1.2.180.13
This trap is issued when the calibration data CRC is incorrect.