Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 lenv 1.3.6.1.4.1.9.2.1
     envPresent 1.3.6.1.4.1.9.2.1.77 integer read-only
Is there an environmental monitor card in this box?, 0 - No, 1-AGS card present, wrong firmware, 2-AGS CARD present, firmware ok, 3-7000 support
     envTestPt1Descr 1.3.6.1.4.1.9.2.1.78 displaystring read-only
Description of the test point 1. Typically ambient air or the temperature of air entering the router
     envTestPt1Measure 1.3.6.1.4.1.9.2.1.79 integer read-only
Current value of test point 1. Typically a temperature in centigrade.
     envTestPt2Descr 1.3.6.1.4.1.9.2.1.80 displaystring read-only
Description of the test point 2. Typically airflow or the temperature of air leaving the router
     envTestPt2Measure 1.3.6.1.4.1.9.2.1.81 integer read-only
Current value of test point 2. Typically a temperature in centigrade.
     envTestPt3Descr 1.3.6.1.4.1.9.2.1.82 displaystring read-only
Description of the test point 3. Typically +5 volt
     envTestPt3Measure 1.3.6.1.4.1.9.2.1.83 integer read-only
Current value of test point 3. Typically the value in millivolts of the +5v supply
     envTestPt4Descr 1.3.6.1.4.1.9.2.1.84 displaystring read-only
Description of the test point 4. Typically +12 volt
     envTestPt4Measure 1.3.6.1.4.1.9.2.1.85 integer read-only
Current value of test point 4. Typically the value in millivolts of the +12v supply
     envTestPt5Descr 1.3.6.1.4.1.9.2.1.86 displaystring read-only
Description of the test point 5. Typically -12 volt
     envTestPt5Measure 1.3.6.1.4.1.9.2.1.87 integer read-only
Current value of test point 5. Typically the value in millivolts of the -12v supply
     envTestPt6Descr 1.3.6.1.4.1.9.2.1.88 displaystring read-only
Description of the test point 6. Typically -5 volt
     envTestPt6Measure 1.3.6.1.4.1.9.2.1.89 integer read-only
Current value of test point 6. Typically the value in millivolts of the -5v supply
     envTestPt1MarginVal 1.3.6.1.4.1.9.2.1.90 integer read-only
Value at which the router will shutdown. Typically the ambient air temperature that will shut the router down. (e.g. 43)
     envTestPt2MarginVal 1.3.6.1.4.1.9.2.1.91 integer read-only
Value at which the router will shutdown. Typically the airflow air temperature that will shut the router down. (e.g. 58)
     envTestPt3MarginPercent 1.3.6.1.4.1.9.2.1.92 integer read-only
+/- Percentage that will shut the router down, (e.g. 10%) typically +5 volt
     envTestPt4MarginPercent 1.3.6.1.4.1.9.2.1.93 integer read-only
+/- Percentage that will shut the router down, (e.g. 15%) typically +12 volt
     envTestPt5MarginPercent 1.3.6.1.4.1.9.2.1.94 integer read-only
+/- Percentage that will shut the router down, (e.g. 15%) typically -12 volt
     envTestPt6MarginPercent 1.3.6.1.4.1.9.2.1.95 integer read-only
+/- Percentage that will shut the router down, (e.g. 10%) typically -5 volt
     envTestPt1last 1.3.6.1.4.1.9.2.1.96 integer read-only
Value of TestPt1 when last shutdown occurred.
     envTestPt2last 1.3.6.1.4.1.9.2.1.97 integer read-only
Value of TestPt2 when last shutdown occurred.
     envTestPt3last 1.3.6.1.4.1.9.2.1.98 integer read-only
Value of TestPt3 when last shutdown occurred.
     envTestPt4last 1.3.6.1.4.1.9.2.1.99 integer read-only
Value of TestPt4 when last shutdown occurred.
     envTestPt5last 1.3.6.1.4.1.9.2.1.100 integer read-only
Value of TestPt5 when last shutdown occurred.
     envTestPt6last 1.3.6.1.4.1.9.2.1.101 integer read-only
Value of TestPt6 when last shutdown occurred.
     envTestPt1warn 1.3.6.1.4.1.9.2.1.102 integer read-only
Is this test point at a warning level? Enumeration: 'noWarning': 2, 'warning': 1.
     envTestPt2warn 1.3.6.1.4.1.9.2.1.103 integer read-only
Is this test point at a warning level? Enumeration: 'noWarning': 2, 'warning': 1.
     envTestPt3warn 1.3.6.1.4.1.9.2.1.104 integer read-only
Is this test point at a warning level? Enumeration: 'noWarning': 2, 'warning': 1.
     envTestPt4warn 1.3.6.1.4.1.9.2.1.105 integer read-only
Is this test point at a warning level? Enumeration: 'noWarning': 2, 'warning': 1.
     envTestPt5warn 1.3.6.1.4.1.9.2.1.106 integer read-only
Is this test point at a warning level? Enumeration: 'noWarning': 2, 'warning': 1.
     envTestPt6warn 1.3.6.1.4.1.9.2.1.107 integer read-only
Is this test point at a warning level? Enumeration: 'noWarning': 2, 'warning': 1.
     envFirmVersion 1.3.6.1.4.1.9.2.1.108 displaystring read-only
Description of Environmental Card firmware
     envTechnicianID 1.3.6.1.4.1.9.2.1.109 displaystring read-only
Technician ID
     envType 1.3.6.1.4.1.9.2.1.110 displaystring read-only
The type of environmental card
     envBurnDate 1.3.6.1.4.1.9.2.1.111 displaystring read-only
The calibration / burn in date
     envSerialNumber 1.3.6.1.4.1.9.2.1.112 displaystring read-only
Serial Number of environmental monitor card