OG-STATUSv2-MIB: View SNMP OID List / Download MIB
VENDOR: OPENGEAR INC.
Home | MIB: OG-STATUSv2-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
ogStatus2 | 1.3.6.1.4.1.25049.17 |
Opengear extended status and alert MIB |
||
ogSystem | 1.3.6.1.4.1.25049.17.1 | |||
ogFirmwareVersion | 1.3.6.1.4.1.25049.17.1.1 | displaystring | read-only |
The current device firmware. |
ogSerialNumber | 1.3.6.1.4.1.25049.17.1.2 | displaystring | read-only |
The current serial number (if applicable). |
ogSerialPortTable | 1.3.6.1.4.1.25049.17.2 | no-access |
The devices serial port status table. |
|
1.3.6.1.4.1.25049.17.2.1 | no-access |
A serial port status entry. |
||
ogSerialPortIndex | 1.3.6.1.4.1.25049.17.2.1.1 | integer32 | no-access |
Index within the serial port table of this status |
ogSerialPortLabel | 1.3.6.1.4.1.25049.17.2.1.2 | displaystring | read-only |
Serial port descriptive name |
ogSerialPortSpeed | 1.3.6.1.4.1.25049.17.2.1.3 | integer32 | read-only |
Serial port speed in bits per second |
ogSerialPortDataBits | 1.3.6.1.4.1.25049.17.2.1.4 | integer32 | read-only |
Serial port character size |
ogSerialPortParity | 1.3.6.1.4.1.25049.17.2.1.5 | integer | read-only |
Serial port parity Enumeration: 'even': 3, 'none': 1, 'space': 5, 'odd': 2, 'mark': 4. |
ogSerialPortStopBits | 1.3.6.1.4.1.25049.17.2.1.6 | integer | read-only |
Serial port number of stop bits Enumeration: 'oneAndAHalf': 3, 'two': 2, 'one': 1. |
ogSerialPortFlowControl | 1.3.6.1.4.1.25049.17.2.1.7 | integer | read-only |
Serial port flow control type Enumeration: 'hardware': 2, 'none': 1, 'software': 3. |
ogSerialPortMode | 1.3.6.1.4.1.25049.17.2.1.8 | integer | read-only |
Serial port operational mode type Enumeration: 'sdt': 3, 'terminal': 4, 'none': 1, 'console': 2, 'bridge': 5. |
ogSerialPortLogLevel | 1.3.6.1.4.1.25049.17.2.1.9 | integer | read-only |
Serial port logging level Enumeration: 'disabled': 1, 'inputAndOutput': 3, 'inputOnly': 4, 'connect': 2, 'outputOnly': 5. |
ogSerialPortRxBytes | 1.3.6.1.4.1.25049.17.2.1.10 | counter64 | read-only |
Serial port bytes received |
ogSerialPortTxBytes | 1.3.6.1.4.1.25049.17.2.1.11 | counter64 | read-only |
Serial port bytes transmitted |
ogSerialPortFramingErrors | 1.3.6.1.4.1.25049.17.2.1.12 | counter64 | read-only |
Serial port framing error total. |
ogSerialPortParityErrors | 1.3.6.1.4.1.25049.17.2.1.13 | counter64 | read-only |
Serial port parity error total. |
ogSerialPortOverrunErrors | 1.3.6.1.4.1.25049.17.2.1.14 | counter64 | read-only |
Serial port Overrun Error total. |
ogSerialPortBreaks | 1.3.6.1.4.1.25049.17.2.1.15 | counter64 | read-only |
Serial port break total |
ogSerialPortDCD | 1.3.6.1.4.1.25049.17.2.1.16 | integer | read-only |
The status of the DCD signal. Enumeration: 'on': 1, 'off': 2. |
ogSerialPortDTR | 1.3.6.1.4.1.25049.17.2.1.17 | integer | read-only |
The status of the DTR signal. Enumeration: 'on': 1, 'off': 2. |
ogSerialPortDSR | 1.3.6.1.4.1.25049.17.2.1.18 | integer | read-only |
The status of the DSR signal. Enumeration: 'on': 1, 'off': 2. |
ogSerialPortCTS | 1.3.6.1.4.1.25049.17.2.1.19 | integer | read-only |
The status of the CTS signal. Enumeration: 'on': 1, 'off': 2. |
ogSerialPortRTS | 1.3.6.1.4.1.25049.17.2.1.20 | integer | read-only |
The status of the RTS signal. Enumeration: 'on': 1, 'off': 2. |
ogSerialUserTable | 1.3.6.1.4.1.25049.17.3 | no-access |
This entity's serial port users table. |
|
1.3.6.1.4.1.25049.17.3.1 | no-access |
A user logged in on the serial port |
||
ogSerialUserIndex | 1.3.6.1.4.1.25049.17.3.1.1 | integer32 | no-access |
Index within the serial port active users table |
ogSerialUserStartTime | 1.3.6.1.4.1.25049.17.3.1.2 | dateandtime | read-only |
The time and date the user session started. |
ogSerialUserPort | 1.3.6.1.4.1.25049.17.3.1.3 | integer32 | read-only |
Serial port number |
ogSerialUserLabel | 1.3.6.1.4.1.25049.17.3.1.4 | displaystring | read-only |
The readable label for the serial port. |
ogSerialUserName | 1.3.6.1.4.1.25049.17.3.1.5 | displaystring | read-only |
The name of the user logged in on the port. |
ogHostTable | 1.3.6.1.4.1.25049.17.4 | no-access |
A table of monitored network hosts. |
|
1.3.6.1.4.1.25049.17.4.1 | no-access |
A monitored network host. |
||
ogHostIndex | 1.3.6.1.4.1.25049.17.4.1.1 | integer32 | no-access |
Index within the network host active users table |
ogHostName | 1.3.6.1.4.1.25049.17.4.1.2 | displaystring | read-only |
The name of this monitored network host. |
ogHostIpV4Address | 1.3.6.1.4.1.25049.17.4.1.3 | displaystring | read-only |
The IPv4 Address of this monitored network host. |
ogHostIpV6Address | 1.3.6.1.4.1.25049.17.4.1.4 | displaystring | read-only |
The IPv6 Address of this monitored network host. |
ogHostServiceTable | 1.3.6.1.4.1.25049.17.5 | no-access |
A table of services belonging to a monitored host. |
|
1.3.6.1.4.1.25049.17.5.1 | no-access |
A monitored host service. |
||
ogHostServiceIndex | 1.3.6.1.4.1.25049.17.5.1.1 | integer32 | no-access |
Index within the RPC outlet table |
ogHostServiceHost | 1.3.6.1.4.1.25049.17.5.1.2 | object identifier | read-only |
The monitored host this service belongs to |
ogHostServiceType | 1.3.6.1.4.1.25049.17.5.1.3 | integer | read-only |
The type of service this is. Enumeration: 'udp': 2, 'tcp': 1. |
ogHostServicePort | 1.3.6.1.4.1.25049.17.5.1.4 | unsigned32 | read-only |
The TCP Port this service is on. |
ogHostServiceStatus | 1.3.6.1.4.1.25049.17.5.1.5 | integer | read-only |
The availabalilty of this service. Enumeration: 'available': 2, 'unknown': 1, 'unavailable': 3. |
ogHostServiceCounter | 1.3.6.1.4.1.25049.17.5.1.6 | counter32 | read-only |
The number of alerts related to this service. |
ogHostUserTable | 1.3.6.1.4.1.25049.17.6 | no-access |
This entity's serial port users table. |
|
1.3.6.1.4.1.25049.17.6.1 | no-access |
A user logged in on the serial port |
||
ogHostUserIndex | 1.3.6.1.4.1.25049.17.6.1.1 | integer32 | no-access |
Index within the network host active users table |
ogHostUserHost | 1.3.6.1.4.1.25049.17.6.1.2 | object identifier | read-only |
The monitored host this user is associated with. |
ogHostUserStartTime | 1.3.6.1.4.1.25049.17.6.1.3 | dateandtime | read-only |
The date and time the user session started. |
ogHostUserAddress | 1.3.6.1.4.1.25049.17.6.1.4 | displaystring | read-only |
The network host address. |
ogHostUserHostName | 1.3.6.1.4.1.25049.17.6.1.5 | displaystring | read-only |
The network host's host name. |
ogHostUserName | 1.3.6.1.4.1.25049.17.6.1.6 | displaystring | read-only |
The network host's active username. |
ogWebUserTable | 1.3.6.1.4.1.25049.17.7 | no-access |
This entity's serial port users table. |
|
1.3.6.1.4.1.25049.17.7.1 | no-access |
A user logged in on the serial port |
||
ogWebUserIndex | 1.3.6.1.4.1.25049.17.7.1.1 | integer32 | no-access |
Index within the network host active users table |
ogWebUserStartTime | 1.3.6.1.4.1.25049.17.7.1.2 | dateandtime | read-only |
The web users session start date and time. |
ogWebUserName | 1.3.6.1.4.1.25049.17.7.1.3 | displaystring | read-only |
The web users active username. |
ogWebUserSourceAddress | 1.3.6.1.4.1.25049.17.7.1.4 | displaystring | read-only |
The web users source address. |
ogWebUserSourcePort | 1.3.6.1.4.1.25049.17.7.1.5 | integer32 | read-only |
The web users source tcp port. |
ogEmdTable | 1.3.6.1.4.1.25049.17.8 | no-access |
This devices temperature monitoring table. |
|
1.3.6.1.4.1.25049.17.8.1 | no-access |
EMD status entry |
||
ogEmdIndex | 1.3.6.1.4.1.25049.17.8.1.1 | integer32 | no-access |
Index within the EMD status table |
ogEmdName | 1.3.6.1.4.1.25049.17.8.1.2 | displaystring | read-only |
The name of the EMD device. |
ogEmdDescription | 1.3.6.1.4.1.25049.17.8.1.3 | displaystring | read-only |
A description of the EMD device. |
ogEmdEnabled | 1.3.6.1.4.1.25049.17.8.1.4 | integer | read-only |
The enabled status of the EMD Enumeration: 'on': 1, 'off': 2. |
ogEmdLogEnabled | 1.3.6.1.4.1.25049.17.8.1.5 | integer | read-only |
The logging status of the EMD Enumeration: 'on': 1, 'off': 2. |
ogEmdConnectType | 1.3.6.1.4.1.25049.17.8.1.6 | integer | read-only |
How the EMD device is connected. Enumeration: 'serial': 2, 'internal': 1, 'network': 3. |
ogEmdTemperatureTotal | 1.3.6.1.4.1.25049.17.8.1.7 | counter32 | read-only |
The number of temperature sensors contained in this EMD. |
ogEmdHumidityTotal | 1.3.6.1.4.1.25049.17.8.1.8 | counter32 | read-only |
The number of humidity sensors contained in this EMD. |
ogEmdDioInputTotal | 1.3.6.1.4.1.25049.17.8.1.9 | counter32 | read-only |
The number of DIOs contained in this EMD. |
ogEmdTemperatureTable | 1.3.6.1.4.1.25049.17.9 | no-access |
A table of temperature sensors belonging to EMDs |
|
1.3.6.1.4.1.25049.17.9.1 | no-access |
EMD status entry |
||
ogEmdTemperatureIndex | 1.3.6.1.4.1.25049.17.9.1.1 | integer32 | no-access |
Index within the EMD status table |
ogEmdTemperatureEmd | 1.3.6.1.4.1.25049.17.9.1.2 | object identifier | read-only |
The EMD this temperature sensor is related to. |
ogEmdTemperatureName | 1.3.6.1.4.1.25049.17.9.1.3 | displaystring | read-only |
The name of the EMD temperature sensor. |
ogEmdTemperatureDescription | 1.3.6.1.4.1.25049.17.9.1.4 | displaystring | read-only |
A description of the EMD device. |
ogEmdTemperatureValue | 1.3.6.1.4.1.25049.17.9.1.5 | integer32 | read-only |
The current temperature reading on the EMD. |
ogEmdTemperatureCounter | 1.3.6.1.4.1.25049.17.9.1.6 | counter32 | read-only |
Number of alerts triggered on the EMD. |
ogEmdHumidityTable | 1.3.6.1.4.1.25049.17.10 | no-access |
A table of humidity sensors belonging to EMDs. |
|
1.3.6.1.4.1.25049.17.10.1 | no-access |
EMD Humidity sensor status entry. |
||
ogEmdHumidityIndex | 1.3.6.1.4.1.25049.17.10.1.1 | integer32 | no-access |
Index within the EMD status table |
ogEmdHumidityEmd | 1.3.6.1.4.1.25049.17.10.1.2 | object identifier | read-only |
The EMD this humidity sensor is related to. |
ogEmdHumidityName | 1.3.6.1.4.1.25049.17.10.1.3 | displaystring | read-only |
The name of the EMD. |
ogEmdHumidityDescription | 1.3.6.1.4.1.25049.17.10.1.4 | displaystring | read-only |
A description of the EMD device. |
ogEmdHumidityValue | 1.3.6.1.4.1.25049.17.10.1.5 | integer32 | read-only |
The current humidity value on the EMD |
ogEmdHumidityCounter | 1.3.6.1.4.1.25049.17.10.1.6 | counter32 | read-only |
Number of alerts triggered on the EMD |
ogEmdDioTable | 1.3.6.1.4.1.25049.17.11 | no-access |
Ths Digital I/O status table. |
|
1.3.6.1.4.1.25049.17.11.1 | no-access |
Digital I/O status entry |
||
ogEmdDioIndex | 1.3.6.1.4.1.25049.17.11.1.1 | integer32 | no-access |
Index within the Digital I/O status table |
ogEmdDioEmd | 1.3.6.1.4.1.25049.17.11.1.2 | object identifier | read-only |
The EMD this Digital I/O relates to. |
ogEmdDioName | 1.3.6.1.4.1.25049.17.11.1.3 | displaystring | read-only |
The ID of this Digital I/O. |
ogEmdDioDescription | 1.3.6.1.4.1.25049.17.11.1.4 | displaystring | read-only |
A description of this Digital I/O. |
ogEmdDioType | 1.3.6.1.4.1.25049.17.11.1.5 | integer | read-only |
Digital I/O type (TTL Input/Output or High-Voltage Output). Enumeration: 'highVoltageOutput': 2, 'ttlInputOutput': 1. |
ogEmdDioDirection | 1.3.6.1.4.1.25049.17.11.1.6 | integer | read-only |
The direction of the Digital I/O (Input or Output) Enumeration: 'output': 1, 'input': 2. |
ogEmdDioState | 1.3.6.1.4.1.25049.17.11.1.7 | integer | read-only |
The electrical state value of the Digital I/O (Low or High) Enumeration: 'high': 1, 'low': 2. |
ogEmdDioTriggerMode | 1.3.6.1.4.1.25049.17.11.1.8 | integer | read-only |
The Trigger Mode of the Digital I/O Enumeration: 'risingFallingEdge': 4, 'fallingEdge': 3, 'invalid': 1, 'risingEdge': 2. |
ogEmdDioCounter | 1.3.6.1.4.1.25049.17.11.1.9 | counter32 | read-only |
The trigger counter of this Digital I/O |
ogNetInterfaceTable | 1.3.6.1.4.1.25049.17.12 | no-access |
This devices network interface status table. |
|
1.3.6.1.4.1.25049.17.12.1 | no-access |
EMD status entry |
||
ogNetInterfaceIndex | 1.3.6.1.4.1.25049.17.12.1.1 | integer32 | no-access |
Index within the network interface status table |
ogNetInterfaceName | 1.3.6.1.4.1.25049.17.12.1.2 | displaystring | read-only |
The name of a network interface. |
ogNetInterfaceType | 1.3.6.1.4.1.25049.17.12.1.3 | integer | read-only |
The type of this network interface entry. Enumeration: 'vpn': 6, 'unavailable': 1, 'wifi': 3, 'v92Modem': 5, 'ethernet': 2, 'cellModem': 4. |
ogNetInterfaceState | 1.3.6.1.4.1.25049.17.12.1.4 | integer | read-only |
The current status of this network interface entry. Enumeration: 'down': 2, 'stopping': 5, 'starting': 3, 'unavailable': 1, 'up': 4. |
ogPowerSupplyTable | 1.3.6.1.4.1.25049.17.13 | no-access |
This entity's Power Supply table. |
|
1.3.6.1.4.1.25049.17.13.1 | no-access |
Power Supply status entry |
||
ogPowerSupplyIndex | 1.3.6.1.4.1.25049.17.13.1.1 | integer32 | no-access |
Index within the Power Supply status table |
ogPowerSupplyName | 1.3.6.1.4.1.25049.17.13.1.2 | displaystring | read-only |
The name of the Power Supply. |
ogPowerSupplyInputVoltage | 1.3.6.1.4.1.25049.17.13.1.3 | integer32 | read-only |
Current temperature of the Power Supply |
ogPowerSupplyOutputCurrent | 1.3.6.1.4.1.25049.17.13.1.4 | integer32 | read-only |
Current temperature of the Power Supply |
ogPowerSupplyTemperature | 1.3.6.1.4.1.25049.17.13.1.5 | integer32 | read-only |
Current temperature of the Power Supply |
ogUpsTable | 1.3.6.1.4.1.25049.17.14 | no-access |
Ths Uninterruptable Power Supply (UPS) status table. |
|
1.3.6.1.4.1.25049.17.14.1 | no-access |
Digital I/O status entry |
||
ogUpsIndex | 1.3.6.1.4.1.25049.17.14.1.1 | integer32 | no-access |
Index within the UPS status table. |
ogUpsName | 1.3.6.1.4.1.25049.17.14.1.2 | displaystring | read-only |
The ID of this UPS. |
ogUpsDescription | 1.3.6.1.4.1.25049.17.14.1.3 | displaystring | read-only |
A description of this UPS. |
ogUpsType | 1.3.6.1.4.1.25049.17.14.1.4 | displaystring | read-only |
The UPS driver type. |
ogUpsLogEnabled | 1.3.6.1.4.1.25049.17.14.1.5 | integer | read-only |
The logging status of the UPS Enumeration: 'on': 1, 'off': 2. |
ogUpsConnectType | 1.3.6.1.4.1.25049.17.14.1.6 | integer | read-only |
How the UPS device is being monitored. Enumeration: 'http': 3, 'usb': 2, 'unknown': 1, 'snmp': 5, 'https': 4, 'serial': 6. |
ogUpsState | 1.3.6.1.4.1.25049.17.14.1.7 | integer | read-only |
The current state the UPS is running in. Enumeration: 'onBypass': 5, 'unknown': 1, 'onBattery': 3, 'lowBattery': 4, 'onLine': 2. |
ogUpsTemperature | 1.3.6.1.4.1.25049.17.14.1.8 | integer32 | read-only |
The UPS temperature. Negative if unavailable. |
ogUpsHumidity | 1.3.6.1.4.1.25049.17.14.1.9 | integer32 | read-only |
The UPS humidity. Negative if unavailable. |
ogUpsBatteryState | 1.3.6.1.4.1.25049.17.14.1.10 | integer | read-only |
The current state of the UPS battery. Enumeration: 'depleted': 5, 'unknown': 1, 'warning': 3, 'low': 4, 'normal': 2. |
ogUpsBatteryRunTime | 1.3.6.1.4.1.25049.17.14.1.11 | integer32 | read-only |
Battery runtime (seconds). Negative if unavailable |
ogUpsBatteryRunTimeLow | 1.3.6.1.4.1.25049.17.14.1.12 | integer32 | read-only |
Estimated remaining battery runtime when UPS switches to Low Battery. Negative if unavailable. |
ogUpsBatteryRunTimeRestart | 1.3.6.1.4.1.25049.17.14.1.13 | integer32 | read-only |
Minimum battery runtime for UPS restart after power-off (seconds). Negative if unavailable. |
ogUpsBatteryCharge | 1.3.6.1.4.1.25049.17.14.1.14 | integer32 | read-only |
Estimated percent of Battery charge remaining. Negative if unavailable. |
ogUpsBatteryVoltage | 1.3.6.1.4.1.25049.17.14.1.15 | integer32 | read-only |
The magnitude of the current battery voltage. Negative if unavailable. |
ogUpsBatteryNominalVoltage | 1.3.6.1.4.1.25049.17.14.1.16 | integer32 | read-only |
Nominal battery voltage (V). Negative if unavailable. |
ogUpsBatteryCurrent | 1.3.6.1.4.1.25049.17.14.1.17 | integer32 | read-only |
The UPS battery current. Negative if unavailable. |
ogUpsBatteryNominalCurrent | 1.3.6.1.4.1.25049.17.14.1.18 | integer32 | read-only |
The nominal UPS battery current. Negative if unavailable. |
ogUpsBatteryTemperature | 1.3.6.1.4.1.25049.17.14.1.19 | integer32 | read-only |
The UPS battery temperature. Negative if unavailable. |
ogUpsInputFrequency | 1.3.6.1.4.1.25049.17.14.1.20 | integer32 | read-only |
Input line frequency (Hz). Negative if unavailable. |
ogUpsInputNominalFrequency | 1.3.6.1.4.1.25049.17.14.1.21 | integer32 | read-only |
Nominal input line frequency (Hz). Negative if unavailable. |
ogUpsInputVoltage | 1.3.6.1.4.1.25049.17.14.1.22 | integer32 | read-only |
The magnitude of the UPS input voltage. Negative if unavailable. |
ogUpsInputNominalVoltage | 1.3.6.1.4.1.25049.17.14.1.23 | integer32 | read-only |
The nominal input voltage. Negative if unavailable. |
ogUpsInputCurrent | 1.3.6.1.4.1.25049.17.14.1.24 | integer32 | read-only |
The input current. Negative if unavailable. |
ogUpsInputNominalCurrent | 1.3.6.1.4.1.25049.17.14.1.25 | integer32 | read-only |
The nominal input current. Negative if unavailable. |
ogUpsOutputFrequency | 1.3.6.1.4.1.25049.17.14.1.26 | integer32 | read-only |
Output line frequency (Hz). Negative if unavailable. |
ogUpsOutputNominalFrequency | 1.3.6.1.4.1.25049.17.14.1.27 | integer32 | read-only |
Nominal output line frequency (Hz). Negative if unavailable. |
ogUpsOutputVoltage | 1.3.6.1.4.1.25049.17.14.1.28 | integer32 | read-only |
The magnitude of the UPS output voltage. Negative if unavailable. |
ogUpsOutputNominalVoltage | 1.3.6.1.4.1.25049.17.14.1.29 | integer32 | read-only |
The nominal magnitude of the UPS output voltage. Negative if unavailable. |
ogUpsOutputCurrent | 1.3.6.1.4.1.25049.17.14.1.30 | integer32 | read-only |
The magnitude of the UPS input current. Negative if unavailable. |
ogUpsOutputNominalCurrent | 1.3.6.1.4.1.25049.17.14.1.31 | integer32 | read-only |
The nominal magnitude of the UPS input current. Negative if unavailable. |
ogUpsOutputLoad | 1.3.6.1.4.1.25049.17.14.1.32 | integer32 | read-only |
Estimated percent of UPS power capacity being used. |
ogUpsOutputPower | 1.3.6.1.4.1.25049.17.14.1.33 | integer32 | read-only |
The current value of apparent power (Volt-Amps). Negative if unavailable. |
ogUpsOutputTruePower | 1.3.6.1.4.1.25049.17.14.1.34 | integer32 | read-only |
The current value of real power (Watts). Negative if unavailable. |
ogUpsCounter | 1.3.6.1.4.1.25049.17.14.1.35 | counter32 | read-only |
Number of alerts triggered on the UPS |
ogRpcTable | 1.3.6.1.4.1.25049.17.15 | no-access |
This entity's Remote Power Controller (RPC) table. |
|
1.3.6.1.4.1.25049.17.15.1 | no-access |
RPC status entry |
||
ogRpcIndex | 1.3.6.1.4.1.25049.17.15.1.1 | integer32 | no-access |
Index within the RPC status table |
ogRpcName | 1.3.6.1.4.1.25049.17.15.1.2 | displaystring | read-only |
The name of the RPC device. |
ogRpcDescription | 1.3.6.1.4.1.25049.17.15.1.3 | displaystring | read-only |
A description for the RPC device. |
ogRpcType | 1.3.6.1.4.1.25049.17.15.1.4 | displaystring | read-only |
A type for the RPC device. |
ogRpcLogEnabled | 1.3.6.1.4.1.25049.17.15.1.5 | integer | read-only |
The logging status of the RPC Enumeration: 'on': 1, 'off': 2. |
ogRpcOutletTotal | 1.3.6.1.4.1.25049.17.15.1.6 | counter32 | read-only |
The number of outlets on this RPC |
ogRpcMaxTemperature | 1.3.6.1.4.1.25049.17.15.1.7 | integer32 | read-only |
Maximum temperature on the RPC |
ogRpcConnectType | 1.3.6.1.4.1.25049.17.15.1.8 | integer | read-only |
How the RPC device is connected. Enumeration: 'serial': 1, 'network': 2. |
ogRpcInputFrequency | 1.3.6.1.4.1.25049.17.15.1.9 | integer32 | read-only |
Input line frequency (Hz). Negative if unavailable. |
ogRpcInputVoltage | 1.3.6.1.4.1.25049.17.15.1.10 | integer32 | read-only |
The magnitude of the RPC input voltage. Negative if unavailable. |
ogRpcInputCurrent | 1.3.6.1.4.1.25049.17.15.1.11 | integer32 | read-only |
The input current. Negative if unavailable. |
ogRpcCounter | 1.3.6.1.4.1.25049.17.15.1.12 | counter32 | read-only |
Number of alerts triggered on the RPC |
ogRpcOutletTable | 1.3.6.1.4.1.25049.17.16 | no-access |
This RPC's outlet table. |
|
1.3.6.1.4.1.25049.17.16.1 | no-access |
RPC Outlet status entry |
||
ogRpcOutletIndex | 1.3.6.1.4.1.25049.17.16.1.1 | integer32 | no-access |
Index within the RPC outlet table |
ogRpcOutletRpc | 1.3.6.1.4.1.25049.17.16.1.2 | object identifier | read-only |
The RPC this outlet belongs to |
ogRpcOutletName | 1.3.6.1.4.1.25049.17.16.1.3 | displaystring | read-only |
The name of the RPC outlet. |
ogRpcOutletState | 1.3.6.1.4.1.25049.17.16.1.4 | integer | read-only |
The power status of the RPC outlet Enumeration: 'on': 1, 'transitioning': 3, 'off': 2, 'unavailable': 4. |
ogRpcOutletFrequency | 1.3.6.1.4.1.25049.17.16.1.5 | integer32 | read-only |
Output line frequency (Hz). Negative if unavailable. |
ogRpcOutletVoltage | 1.3.6.1.4.1.25049.17.16.1.6 | integer32 | read-only |
The voltage on this outlet. Negative if unavailable. |
ogRpcOutletCurrent | 1.3.6.1.4.1.25049.17.16.1.7 | integer32 | read-only |
Current measured on this outlet. Negative if unavailable. |
ogRpcOutletLoad | 1.3.6.1.4.1.25049.17.16.1.8 | integer32 | read-only |
Estimated percent of RPC outlet power capacity being used. |
ogCellModemTable | 1.3.6.1.4.1.25049.17.17 | no-access |
Ths cellular modem status table. |
|
1.3.6.1.4.1.25049.17.17.1 | no-access |
A cellular modem status entry. |
||
ogCellModemIndex | 1.3.6.1.4.1.25049.17.17.1.1 | integer32 | no-access |
Index of the cellular modem status entry. |
ogCellModemVendor | 1.3.6.1.4.1.25049.17.17.1.2 | displaystring | read-only |
The Manufacturer ID of Cellular Modem. |
ogCellModemModel | 1.3.6.1.4.1.25049.17.17.1.3 | displaystring | read-only |
The Cellular Modem model name. |
ogCellModemEnabled | 1.3.6.1.4.1.25049.17.17.1.4 | integer | read-only |
The enabled state of the modem. Enumeration: 'disabled': 2, 'enabled': 1. |
ogCellModemConnected | 1.3.6.1.4.1.25049.17.17.1.5 | integer | read-only |
The connected state of the modem. Enumeration: 'connected': 1, 'disconnected': 2. |
ogCellModemNetwork | 1.3.6.1.4.1.25049.17.17.1.6 | displaystring | read-only |
The name of the network provider. |
ogCellModemRegistered | 1.3.6.1.4.1.25049.17.17.1.7 | integer | read-only |
The registration state of the modem. Enumeration: 'unregistered': 2, 'registered': 1. |
ogCellModemTower | 1.3.6.1.4.1.25049.17.17.1.8 | integer32 | read-only |
The current cellular tower ID. |
ogCellModemRadioTechnology | 1.3.6.1.4.1.25049.17.17.1.9 | integer | read-only |
The current Radio Access Technology being used Enumeration: 'unavailable': 1, 'evdo': 3, 'umts': 5, 'lte': 6, 'cdma': 2, 'gsm': 4. |
ogCellModemApn | 1.3.6.1.4.1.25049.17.17.1.10 | displaystring | read-only |
The APN configured for this cellmodem. |
ogCellModem3gRssi | 1.3.6.1.4.1.25049.17.17.1.11 | integer32 | read-only |
The current 3G Received Signal Strength (RSSI) if applicable. |
ogCellModem4gRssi | 1.3.6.1.4.1.25049.17.17.1.12 | integer32 | read-only |
The current 4G Received Signal Strength (RSSI) if applicable. |
ogCellModemSessionTime | 1.3.6.1.4.1.25049.17.17.1.13 | counter32 | read-only |
The number of seconds the modem session has been up for. |
ogCellModemSelectedSimCard | 1.3.6.1.4.1.25049.17.17.1.14 | counter32 | read-only |
The SIM card currently being used by this modem. |
ogCellModemTemperature | 1.3.6.1.4.1.25049.17.17.1.15 | integer32 | read-only |
The current temperature of the Cellular Modem. |
ogCellModemCounter | 1.3.6.1.4.1.25049.17.17.1.16 | counter32 | read-only |
The number of alerts the modem has triggered. |
ogWifiClientTable | 1.3.6.1.4.1.25049.17.18 | no-access |
Ths wireless client status table. |
|
1.3.6.1.4.1.25049.17.18.1 | no-access |
A wireless client status entry. |
||
ogWifiClientIndex | 1.3.6.1.4.1.25049.17.18.1.1 | integer32 | no-access |
Index of the wireless client status entry. |
ogWifiClientInterface | 1.3.6.1.4.1.25049.17.18.1.2 | displaystring | read-only |
The wireless client network interface name. |
ogWifiClientEnabled | 1.3.6.1.4.1.25049.17.18.1.3 | integer | read-only |
The wireless client enabled state Enumeration: 'on': 1, 'off': 2. |
ogWifiClientEssid | 1.3.6.1.4.1.25049.17.18.1.4 | displaystring | read-only |
The ESSID this wireless client is currently associated with. |
ogWifiClientIeeeMode | 1.3.6.1.4.1.25049.17.18.1.5 | integer | read-only |
The IEEE 802.11 mode of this wireless client. Enumeration: 'ieee802Dot11B': 2, 'ieee802Dot11BGN': 4, 'ieee802Dot11ABGN': 5, 'unavailable': 1, 'ieee802Dot11BG': 3. |
ogWifiClientMode | 1.3.6.1.4.1.25049.17.18.1.6 | integer | read-only |
The operating mode of this wireless client. Enumeration: 'managed': 2, 'unavailable': 1, 'adhoc': 3. |
ogWifiClientFrequency | 1.3.6.1.4.1.25049.17.18.1.7 | unsigned32 | read-only |
The current frequency of this wireless client. |
ogWifiClientApMac | 1.3.6.1.4.1.25049.17.18.1.8 | displaystring | read-only |
The Access Point ID this wireless client is associated with. |
ogWifiClientBitRate | 1.3.6.1.4.1.25049.17.18.1.9 | unsigned32 | read-only |
The current bit-rate of this wireless client. |
ogWifiClientTxPower | 1.3.6.1.4.1.25049.17.18.1.10 | integer32 | read-only |
The current Tx-Power of this wireless client. |
ogWifiClientLinkQuality | 1.3.6.1.4.1.25049.17.18.1.11 | unsigned32 | read-only |
The normalized link quality of this wireless client. |
ogWifiClientRssi | 1.3.6.1.4.1.25049.17.18.1.12 | integer32 | read-only |
The current Signal Level of this wireless client. |
ogWifiClientRxInvalidNwid | 1.3.6.1.4.1.25049.17.18.1.13 | counter32 | read-only |
The count of invalid Network ID's for this wireless client. |
ogWifiClientRxInvalidCrypt | 1.3.6.1.4.1.25049.17.18.1.14 | counter32 | read-only |
The count of invalid crypt's for this wireless client. |
ogWifiClientRxInvalidFrag | 1.3.6.1.4.1.25049.17.18.1.15 | counter32 | read-only |
The count of invalid frag's for this wireless client. |
ogWifiClientRxInvalidRetries | 1.3.6.1.4.1.25049.17.18.1.16 | counter32 | read-only |
The count of invalid retries for this wireless client. |
ogWifiClientRxInvalidMisc | 1.3.6.1.4.1.25049.17.18.1.17 | counter32 | read-only |
The count of invalid misc's for this wireless client. |
ogWifiClientMissedBeacon | 1.3.6.1.4.1.25049.17.18.1.18 | counter32 | read-only |
The count of missed beacon's for this wireless client. |
ogWifiClientCounter | 1.3.6.1.4.1.25049.17.18.1.19 | counter32 | read-only |
The number of alerts triggered by this wireless client. |
ogWifiApTable | 1.3.6.1.4.1.25049.17.19 | no-access |
Ths wireless interface status table. |
|
1.3.6.1.4.1.25049.17.19.1 | no-access |
A wireless interface status entry |
||
ogWifiApIndex | 1.3.6.1.4.1.25049.17.19.1.1 | integer32 | no-access |
Index of the wireless server status entry. |
ogWifiApInterface | 1.3.6.1.4.1.25049.17.19.1.2 | displaystring | read-only |
The wireless access point network interface name. |
ogWifiApEnabled | 1.3.6.1.4.1.25049.17.19.1.3 | integer | read-only |
The enabled status of the wireless server. Enumeration: 'on': 1, 'off': 2. |
ogWifiApSsid | 1.3.6.1.4.1.25049.17.19.1.4 | displaystring | read-only |
The SSID for this wireless access point. |
ogWifiApIeeeMode | 1.3.6.1.4.1.25049.17.19.1.5 | integer | read-only |
The IEEE 802.11 mode of this wireless access point. Enumeration: 'ieee802Dot11B': 2, 'ieee802Dot11BGN': 4, 'ieee802Dot11ABGN': 5, 'unavailable': 1, 'ieee802Dot11BG': 3. |
ogWifiApFrequency | 1.3.6.1.4.1.25049.17.19.1.6 | unsigned32 | read-only |
The current frequency of this wireless access point. |
ogWifiApTxPower | 1.3.6.1.4.1.25049.17.19.1.7 | integer32 | read-only |
The current Tx-Power of this wireless access point. |
ogWifiApCounter | 1.3.6.1.4.1.25049.17.19.1.8 | counter32 | read-only |
The number of alerts triggered by this wireless access point. |
ogWifiApClientTable | 1.3.6.1.4.1.25049.17.20 | no-access |
This RPC's outlet table. |
|
1.3.6.1.4.1.25049.17.20.1 | no-access |
RPC Outlet status entry |
||
ogWifiApClientIndex | 1.3.6.1.4.1.25049.17.20.1.1 | integer32 | no-access |
Index within the wireless AP client table |
ogWifiApClientAp | 1.3.6.1.4.1.25049.17.20.1.2 | object identifier | read-only |
The wireless AP this client is assiciated with. |
ogWifiApClientMac | 1.3.6.1.4.1.25049.17.20.1.3 | displaystring | read-only |
The MAC address of the Access Point this wireless client is associated with. |
ogWifiApClientInactiveTime | 1.3.6.1.4.1.25049.17.20.1.4 | counter32 | read-only |
The Inactive Time for this wireless client. |
ogWifiApClientRxBytes | 1.3.6.1.4.1.25049.17.20.1.5 | counter32 | read-only |
The number of received bytes for this wireless client. |
ogWifiApClientRxPackets | 1.3.6.1.4.1.25049.17.20.1.6 | counter32 | read-only |
The number of received packets for this wireless client. |
ogWifiApClientTxBytes | 1.3.6.1.4.1.25049.17.20.1.7 | counter32 | read-only |
The number of transmitted bytes for this wireless client. |
ogWifiApClientTxPackets | 1.3.6.1.4.1.25049.17.20.1.8 | counter32 | read-only |
The number of transmitted packets for this wireless client. |
ogWifiApClientRssi | 1.3.6.1.4.1.25049.17.20.1.9 | integer32 | read-only |
The current Signal Level of this wireless client. |
ogWifiApClientTxBitRate | 1.3.6.1.4.1.25049.17.20.1.10 | unsigned32 | read-only |
The current transmission bit-rate of this wireless client. |
ogCheckTable | 1.3.6.1.4.1.25049.17.21 | no-access |
Ths auto-response check table. |
|
1.3.6.1.4.1.25049.17.21.1 | no-access |
An auto-response check entry |
||
ogCheckIndex | 1.3.6.1.4.1.25049.17.21.1.1 | integer32 | no-access |
Index of the auto-response rule |
ogCheckName | 1.3.6.1.4.1.25049.17.21.1.2 | displaystring | read-only |
The ID of this auto-response rule. |
ogCheckRepeatTimeout | 1.3.6.1.4.1.25049.17.21.1.3 | integer32 | read-only |
The minimum seconds before trigger actions can be repeated for this auto-response. |
ogCheckResetTimeout | 1.3.6.1.4.1.25049.17.21.1.4 | integer32 | read-only |
The minimum seconds after resolution before this auto-response can be triggered again. |
ogCheckType | 1.3.6.1.4.1.25049.17.21.1.5 | integer | read-only |
The auto-response check type Enumeration: 'cellData': 27, 'powerSupplyOutputCurrent': 14, 'cellMessage': 26, 'rpcInput': 23, 'serialPattern': 4, 'upsBatteryTemperature': 18, 'upsInputVoltage': 16, 'wirelessApAssociation': 34, 'envTemperature': 9, 'unknown': 1, 'rpcOutletState': 24, 'wirelessClientConnect': 32, 'cellNetwork': 31, 'powerSupplyTemperature': 15, 'custom': 255, 'upsInputFrequency': 20, 'dioInput': 11, 'hostService': 6, 'upsOutputLoad': 19, 'upsStateLowBattery': 22, 'upsBatteryCharge': 17, 'netInterface': 12, 'powerSupplyInputVoltage': 13, 'rpcOutletOutput': 25, 'serialSignal': 2, 'wirelessClientSignal': 33, 'envHumidity': 10, 'cellApn': 29, 'upsStateOnBattery': 21, 'cellSignal': 28, 'webUser': 8, 'serialUser': 3, 'cellTower': 30, 'wirelessApAuthentication': 35, 'dialPoolHealth': 36, 'hostUser': 7, 'hostPing': 5. |
ogCheckTriggerActions | 1.3.6.1.4.1.25049.17.21.1.6 | counter32 | read-only |
The number of Trigger Actions configured for the auto-response. |
ogCheckResolveActions | 1.3.6.1.4.1.25049.17.21.1.7 | counter32 | read-only |
The number of Resolve Actions configured for the auto-response. |
ogCheckDeviceTable | 1.3.6.1.4.1.25049.17.22 | no-access |
The auto-response device reference table. |
|
1.3.6.1.4.1.25049.17.22.1 | no-access |
RPC Outlet status entry |
||
ogCheckDeviceIndex | 1.3.6.1.4.1.25049.17.22.1.1 | integer32 | no-access |
Index within the auto-response device outlet table |
ogCheckDeviceCheck | 1.3.6.1.4.1.25049.17.22.1.2 | object identifier | read-only |
The check this device is associated with. |
ogCheckDeviceName | 1.3.6.1.4.1.25049.17.22.1.3 | displaystring | read-only |
The name of a device pertaining to the auto-reponse. |
ogCheckDeviceRef | 1.3.6.1.4.1.25049.17.22.1.4 | displaystring | read-only |
The reference ID of the device pertaining to the auto-reponse. |
ogAlarm | 1.3.6.1.4.1.25049.17.23 | |||
ogAlarmLogTable | 1.3.6.1.4.1.25049.17.23.1 | no-access |
The alarm history table. |
|
1.3.6.1.4.1.25049.17.23.1.1 | no-access |
An alarm entry. |
||
ogAlarmLogIndex | 1.3.6.1.4.1.25049.17.23.1.1.1 | integer32 | no-access |
Index within the current alarm table of this alarm. |
ogAlarmEventId | 1.3.6.1.4.1.25049.17.23.1.1.2 | integer32 | read-only |
Unique event ID for this alarm. |
ogAlarmName | 1.3.6.1.4.1.25049.17.23.1.1.3 | displaystring | read-only |
The check ID that this alarm pertains to. |
ogAlarmCheck | 1.3.6.1.4.1.25049.17.23.1.1.4 | integer32 | read-only |
The auto-response index this alarm relates to. |
ogAlarmInstance | 1.3.6.1.4.1.25049.17.23.1.1.5 | integer32 | read-only |
The reference index for this alarm instance. |
ogAlarmTime | 1.3.6.1.4.1.25049.17.23.1.1.6 | dateandtime | read-only |
The UTC date and time for when this alarm was created. |
ogAlarmType | 1.3.6.1.4.1.25049.17.23.1.1.7 | integer | read-only |
A reference to an Alarm Type Object. Enumeration: 'serialSignalDsr': 3, 'upsInputVoltageLow': 45, 'netInterfaceUp': 21, 'upsInputCurrentHigh': 48, 'netInterfaceStarting': 20, 'rpcInputVoltageHigh': 64, 'upsOutputFrequencyLow': 49, 'upsTemperatureHigh': 29, 'wirelessApAssociation': 86, 'serialSignalDcd': 2, 'netInterfaceDown': 19, 'wirelessApDisassociation': 87, 'rpcOutletCurrentLow': 72, 'upsOutputTruePowerHigh': 60, 'upsOutputPowerLow': 57, 'upsBatteryVoltageLow': 37, 'powerSupplyInputVoltageLow': 23, 'wirelessClientDisconnected': 83, 'rpcOutletCurrentHigh': 71, 'upsOutputCurrentHigh': 54, 'rpcInputFrequencyHigh': 62, 'upsOutputCurrentLow': 53, 'upsOutputFrequencyHigh': 50, 'upsOnBattery': 33, 'upsInputVoltageHigh': 46, 'hostServiceDown': 9, 'rpcOutletVoltageHigh': 69, 'powerSupplyOutputCurrentLow': 25, 'upsBatteryChargeLow': 35, 'powerSupplyInputVoltageHigh': 24, 'envTemperatureHigh': 14, 'customCheckFailure': 255, 'hostPingUp': 8, 'envTemperatureLow': 13, 'upsOutputPowerHigh': 58, 'serialSignalCts': 1, 'serialPatternTx': 4, 'wirelessClientSignalLow': 84, 'upsBatteryTemperatureHigh': 42, 'hostServiceUp': 10, 'rpcOutletStateOff': 73, 'upsInputFrequencyLow': 43, 'powerSupplyTemperatureLow': 27, 'upsOutputLoadLow': 55, 'dialPoolHealth': 89, 'powerSupplyTemperatureHigh': 28, 'dioSignalOpened': 17, 'rpcInputCurrentHigh': 66, 'upsLowBattery': 34, 'rpcOutletFrequencyHigh': 67, 'upsOutputVoltageHigh': 52, 'upsBatteryCurrentHigh': 40, 'unknown': 65535, 'upsOutputTruePowerLow': 59, 'upsBatteryCurrentLow': 39, 'webUserSession': 12, 'cellNetworkChanged': 81, 'wirelessClientSignalHigh': 85, 'hostPingDown': 7, 'rpcOutletFrequencyLow': 68, 'upsInputFrequencyHigh': 44, 'upsOutputVoltageLow': 51, 'cellDataUsage': 75, 'cellTowerChanged': 80, 'serialPatternRx': 5, 'rpcOutletStateOn': 74, 'rpcOutletVoltageLow': 70, 'upsTemperatureLow': 30, 'envHumidityLow': 15, 'envHumidityHigh': 16, 'cellSignalHigh': 78, 'netInterfaceStopping': 22, 'upsHumidityLow': 32, 'upsBatteryVoltageHigh': 38, 'serialUserSession': 6, 'wirelessApAuthenticationFailure': 88, 'upsBatteryTemperatureLow': 41, 'rpcInputCurrentLow': 65, 'upsHumidityHigh': 31, 'upsInputCurrentLow': 47, 'hostUserSession': 11, 'cellApnChanged': 79, 'upsOutputLoadHigh': 56, 'cellSignalLow': 77, 'wirelessClientConnected': 82, 'powerSupplyOutputCurrentHigh': 26, 'cellMessageReceived': 76, 'dioSignalClosed': 18, 'upsBatteryChargeHigh': 36, 'rpcInputVoltageLow': 63, 'rpcInputFrequencyLow': 61. |
ogAlarmSummary | 1.3.6.1.4.1.25049.17.23.1.1.8 | displaystring | read-only |
The human readable summary of this alarm. |
ogAlarmDevice | 1.3.6.1.4.1.25049.17.23.1.1.9 | displaystring | read-only |
The device ID that this alarm pertains to. |
ogAlarmUser | 1.3.6.1.4.1.25049.17.23.1.1.10 | displaystring | read-only |
The user ID that this alarm pertains to. |
ogAlarmTriggerValue | 1.3.6.1.4.1.25049.17.23.1.1.11 | integer32 | read-only |
The threshold value which triggers the alarm. |
ogAlarmCurrentValue | 1.3.6.1.4.1.25049.17.23.1.1.12 | integer32 | read-only |
The value as of the time of this entry. |
ogAlarmPreviousValue | 1.3.6.1.4.1.25049.17.23.1.1.13 | integer32 | read-only |
The former value of this entry. |
ogAlarmState | 1.3.6.1.4.1.25049.17.23.1.1.14 | integer | read-only |
The effective alarm state. Enumeration: 'triggered': 2, 'unresolvable': 6, 'normal': 1, 'resolving': 3, 'disabled': 5, 'waiting': 4. |
ogCurrentAlarmTable | 1.3.6.1.4.1.25049.17.23.2 | no-access |
The alarm history table. |
|
1.3.6.1.4.1.25049.17.23.2.1 | no-access |
An alarm entry. |
||
ogCurrentAlarmIndex | 1.3.6.1.4.1.25049.17.23.2.1.1 | integer32 | no-access |
Index within the current alarm table of this alarm. |
ogCurrentAlarmEventId | 1.3.6.1.4.1.25049.17.23.2.1.2 | integer32 | read-only |
Unique event ID for this alarm. |
ogCurrentAlarmName | 1.3.6.1.4.1.25049.17.23.2.1.3 | displaystring | read-only |
The ID of the check this alarm pertains to. |
ogCurrentAlarmCheck | 1.3.6.1.4.1.25049.17.23.2.1.4 | integer32 | read-only |
The auto-response index this alarm relates to. |
ogCurrentAlarmInstance | 1.3.6.1.4.1.25049.17.23.2.1.5 | integer32 | read-only |
The reference index for this alarm instance. |
ogCurrentAlarmTime | 1.3.6.1.4.1.25049.17.23.2.1.6 | dateandtime | read-only |
The UTC date and time for when this alarm was created. |
ogCurrentAlarmType | 1.3.6.1.4.1.25049.17.23.2.1.7 | integer | read-only |
The specific Alarm Type. Enumeration: 'serialSignalDsr': 3, 'upsInputVoltageLow': 45, 'netInterfaceUp': 21, 'upsInputCurrentHigh': 48, 'netInterfaceStarting': 20, 'rpcInputVoltageHigh': 64, 'upsOutputFrequencyLow': 49, 'upsTemperatureHigh': 29, 'wirelessApAssociation': 86, 'serialSignalDcd': 2, 'netInterfaceDown': 19, 'wirelessApDisassociation': 87, 'rpcOutletCurrentLow': 72, 'upsOutputTruePowerHigh': 60, 'upsOutputPowerLow': 57, 'upsBatteryVoltageLow': 37, 'powerSupplyInputVoltageLow': 23, 'wirelessClientDisconnected': 83, 'rpcOutletCurrentHigh': 71, 'upsOutputCurrentHigh': 54, 'rpcInputFrequencyHigh': 62, 'upsOutputCurrentLow': 53, 'upsOutputFrequencyHigh': 50, 'upsOnBattery': 33, 'upsInputVoltageHigh': 46, 'hostServiceDown': 9, 'rpcOutletVoltageHigh': 69, 'powerSupplyOutputCurrentLow': 25, 'upsBatteryChargeLow': 35, 'powerSupplyInputVoltageHigh': 24, 'envTemperatureHigh': 14, 'customCheckFailure': 255, 'hostPingUp': 8, 'envTemperatureLow': 13, 'upsOutputPowerHigh': 58, 'serialSignalCts': 1, 'serialPatternTx': 4, 'wirelessClientSignalLow': 84, 'upsBatteryTemperatureHigh': 42, 'hostServiceUp': 10, 'rpcOutletStateOff': 73, 'upsInputFrequencyLow': 43, 'powerSupplyTemperatureLow': 27, 'upsOutputLoadLow': 55, 'dialPoolHealth': 89, 'powerSupplyTemperatureHigh': 28, 'dioSignalOpened': 17, 'rpcInputCurrentHigh': 66, 'upsLowBattery': 34, 'rpcOutletFrequencyHigh': 67, 'upsOutputVoltageHigh': 52, 'upsBatteryCurrentHigh': 40, 'unknown': 65535, 'upsOutputTruePowerLow': 59, 'upsBatteryCurrentLow': 39, 'webUserSession': 12, 'cellNetworkChanged': 81, 'wirelessClientSignalHigh': 85, 'hostPingDown': 7, 'rpcOutletFrequencyLow': 68, 'upsInputFrequencyHigh': 44, 'upsOutputVoltageLow': 51, 'cellDataUsage': 75, 'cellTowerChanged': 80, 'serialPatternRx': 5, 'rpcOutletStateOn': 74, 'rpcOutletVoltageLow': 70, 'upsTemperatureLow': 30, 'envHumidityLow': 15, 'envHumidityHigh': 16, 'cellSignalHigh': 78, 'netInterfaceStopping': 22, 'upsHumidityLow': 32, 'upsBatteryVoltageHigh': 38, 'serialUserSession': 6, 'wirelessApAuthenticationFailure': 88, 'upsBatteryTemperatureLow': 41, 'rpcInputCurrentLow': 65, 'upsHumidityHigh': 31, 'upsInputCurrentLow': 47, 'hostUserSession': 11, 'cellApnChanged': 79, 'upsOutputLoadHigh': 56, 'cellSignalLow': 77, 'wirelessClientConnected': 82, 'powerSupplyOutputCurrentHigh': 26, 'cellMessageReceived': 76, 'dioSignalClosed': 18, 'upsBatteryChargeHigh': 36, 'rpcInputVoltageLow': 63, 'rpcInputFrequencyLow': 61. |
ogCurrentAlarmSummary | 1.3.6.1.4.1.25049.17.23.2.1.8 | displaystring | read-only |
A readable summary of this alarm. |
ogCurrentAlarmDevice | 1.3.6.1.4.1.25049.17.23.2.1.9 | displaystring | read-only |
The ID of the device this alarm pertains to. |
ogCurrentAlarmUser | 1.3.6.1.4.1.25049.17.23.2.1.10 | displaystring | read-only |
The ID of the user this alarm pertains to. |
ogCurrentAlarmTriggerValue | 1.3.6.1.4.1.25049.17.23.2.1.11 | integer32 | read-only |
The threshold value which triggers the alarm. |
ogCurrentAlarmCurrentValue | 1.3.6.1.4.1.25049.17.23.2.1.12 | integer32 | read-only |
The value as of the time of this entry. |
ogCurrentAlarmPreviousValue | 1.3.6.1.4.1.25049.17.23.2.1.13 | integer32 | read-only |
The former value of this entry. |
ogCurrentAlarmState | 1.3.6.1.4.1.25049.17.23.2.1.14 | integer | read-only |
The effective alarm state. Enumeration: 'triggered': 2, 'unresolvable': 6, 'normal': 1, 'resolving': 3, 'disabled': 5, 'waiting': 4. |
ogStatus2NotificationPrefix | 1.3.6.1.4.1.25049.17.100 | |||
ogMibNotifications | 1.3.6.1.4.1.25049.17.100.0 | |||
ogSerialSignalNotification | 1.3.6.1.4.1.25049.17.100.0.1 |
The notification sent when a serial signal changes. |
||
ogSerialPatternNotification | 1.3.6.1.4.1.25049.17.100.0.2 |
The notification sent when a pattern is matched on a serial port . |
||
ogSerialUserNotification | 1.3.6.1.4.1.25049.17.100.0.3 |
The notification sent when a user logs in or out of a serial console. |
||
ogHostPingNotification | 1.3.6.1.4.1.25049.17.100.0.4 |
The notification sent when a host stops or resumes responding to a ping. |
||
ogHostServiceNotification | 1.3.6.1.4.1.25049.17.100.0.5 |
The notification sent when a host service stops or resumes. |
||
ogHostUserNotification | 1.3.6.1.4.1.25049.17.100.0.6 |
The notification sent when a user logs in or out of a network host. |
||
ogWebUserNotification | 1.3.6.1.4.1.25049.17.100.0.7 |
The notification sent when a user logs in or out of the web interface. |
||
ogEmdTemperatureNotification | 1.3.6.1.4.1.25049.17.100.0.8 |
The notification sent when a temperature event occurs |
||
ogEmdHumidityNotification | 1.3.6.1.4.1.25049.17.100.0.9 |
The notification sent when a humidity event occurs |
||
ogEmdDioNotification | 1.3.6.1.4.1.25049.17.100.0.10 |
The notification sent when a Digital I/O input event occurs |
||
ogPowerSupplyInputNotification | 1.3.6.1.4.1.25049.17.100.0.11 |
The notification sent when a power supply voltage alarm occurs |
||
ogPowerSupplyOutputNotification | 1.3.6.1.4.1.25049.17.100.0.12 |
The notification sent when a power supply voltage alarm occurs |
||
ogPowerSupplyTempNotification | 1.3.6.1.4.1.25049.17.100.0.13 |
The notification sent when a power supply voltage alarm occurs |
||
ogUpsNotification | 1.3.6.1.4.1.25049.17.100.0.14 |
The notification sent when a UPS alarm occurs |
||
ogUpsBatteryNotification | 1.3.6.1.4.1.25049.17.100.0.15 |
The notification sent when a UPS battery alarm occurs |
||
ogUpsInputNotification | 1.3.6.1.4.1.25049.17.100.0.16 |
The notification sent when a UPS input alarm occurs |
||
ogUpsOutputNotification | 1.3.6.1.4.1.25049.17.100.0.17 |
The notification sent when a UPS output alarm occurs |
||
ogRpcInputNotification | 1.3.6.1.4.1.25049.17.100.0.18 |
The notification sent when a RPC input alarm occurs |
||
ogRpcOutputNotification | 1.3.6.1.4.1.25049.17.100.0.19 |
The notification sent when a RPC output alarm occurs |
||
ogRpcOutletNotification | 1.3.6.1.4.1.25049.17.100.0.20 |
The notification sent when a RPC output alarm occurs |
||
ogNetInterfaceNotification | 1.3.6.1.4.1.25049.17.100.0.21 |
The notification sent when a network interface event occurs. |
||
ogCellDataNotification | 1.3.6.1.4.1.25049.17.100.0.22 |
The notification sent when a cellular data alarm occurs. |
||
ogCellMessageNotification | 1.3.6.1.4.1.25049.17.100.0.23 |
The notification sent when an SMS command alarm occurs. |
||
ogCellSignalNotification | 1.3.6.1.4.1.25049.17.100.0.24 |
The notification sent when a cellular signal alarm occurs. |
||
ogCellApnNotification | 1.3.6.1.4.1.25049.17.100.0.25 |
The notification sent when a cellular APN alarm occurs. |
||
ogCellTowerNotification | 1.3.6.1.4.1.25049.17.100.0.26 |
The notification sent when a cellular tower alarm occurs. |
||
ogCellNetworkNotification | 1.3.6.1.4.1.25049.17.100.0.27 |
The notification sent when a cellular network alarm occurs. |
||
ogWifiClientConnectNotification | 1.3.6.1.4.1.25049.17.100.0.28 |
The notification sent when a wireless client connects or disconnects. |
||
ogWifiClientSignalNotification | 1.3.6.1.4.1.25049.17.100.0.29 |
The notification sent when a wireless client signal changes. |
||
ogWifiApAssociationNotification | 1.3.6.1.4.1.25049.17.100.0.30 |
The notification sent when a wireless client connects or disconnects to this AP. |
||
ogWifiApAuthNotification | 1.3.6.1.4.1.25049.17.100.0.31 |
The notification sent when a wireless client fails to authenticate with this AP. |
||
ogDialPoolHealthNotification | 1.3.6.1.4.1.25049.17.100.0.32 |
The notification sent when dial-pool health alarm occurs. |
||
ogCustomNotification | 1.3.6.1.4.1.25049.17.100.0.33 |
The notification sent when a custom check is triggered. |
||
ogStatus2Conformance | 1.3.6.1.4.1.25049.17.65535 | |||
ogStatus2Compliances | 1.3.6.1.4.1.25049.17.65535.1 | |||
ogStatus2Compliance | 1.3.6.1.4.1.25049.17.65535.1.1 |
The compliance statement for the Opengear status MIB. |
||
ogStatus2Groups | 1.3.6.1.4.1.25049.17.65535.2 | |||
ogBasicStatusGroup | 1.3.6.1.4.1.25049.17.65535.2.1 |
A collection of objects to retrieve Opengear statistics. |
||
ogBasicAlarmGroup | 1.3.6.1.4.1.25049.17.65535.2.2 |
A collection of objects to report Opengear alarms. |
||
ogBasicNotificationGroup | 1.3.6.1.4.1.25049.17.65535.2.3 |
A collection of notifications for the status system. |