ODS-TRMIB: View SNMP OID List / Download MIB

VENDOR: OPTICAL DATA SYSTEMS


 Home MIB: ODS-TRMIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 ods 1.3.6.1.4.1.50
       enc 1.3.6.1.4.1.50.1
       enBridge 1.3.6.1.4.1.50.2
       tokenRing 1.3.6.1.4.1.50.3
           trMib1 1.3.6.1.4.1.50.3.1
               trSystem 1.3.6.1.4.1.50.3.1.1
                   trBox 1.3.6.1.4.1.50.3.1.1.1
                       boxChassisId 1.3.6.1.4.1.50.3.1.1.1.1 integer read-only
The type of chassis used for the concentrator. For modular concentrators, the hardware is further qualifed by the value of cardId for each card installed in the concentrator. Enumeration: 'ods861-uc': 96, 'ods861-rj45': 112, 'ods290': 32, 'ods840': 64, 'ods841': 80.
                       boxMaxDeinCount 1.3.6.1.4.1.50.3.1.1.1.4 integer read-write
Contains the maximum number of successive de-inserts that can occur before a given port is shut off automatically.
                       boxMaxDeinDelta 1.3.6.1.4.1.50.3.1.1.1.5 integer read-write
The maximum time in seconds between successive de-inserts for a given port for which the portDeinCount will be incremeneted.
                       boxReset 1.3.6.1.4.1.50.3.1.1.1.7 integer read-write
Setting to 1 will reboot the agent.
                       boxFWVersion 1.3.6.1.4.1.50.3.1.1.1.8 displaystring read-only
The version of the firmware that is currently resident.
                       trapId 1.3.6.1.4.1.50.3.1.1.1.9 integer no-access
The trap Id for this particular trap. It is a one-up counter that identifies this trap.
                       changedOid 1.3.6.1.4.1.50.3.1.1.1.10 object identifier no-access
The Object Id of the variable that is the reason for sending the trap.
                       changedValue 1.3.6.1.4.1.50.3.1.1.1.11 integer no-access
The value of the variable that is being trapped.
                       changedDescr 1.3.6.1.4.1.50.3.1.1.1.12 displaystring no-access
A textual description of the variable, the slot, the port, and the new value that is being trapped.
                       tftpAddress 1.3.6.1.4.1.50.3.1.1.1.13 ipaddress read-write
The IP address from which TFTP packets will be accepted by the agent.
                       dosCommand 1.3.6.1.4.1.50.3.1.1.1.14 displaystring read-write
A Dos command that will be executed.
                       dosExitCode 1.3.6.1.4.1.50.3.1.1.1.15 integer read-only
The status of the last executed DOS command.
                       enbBcnIsoAlg 1.3.6.1.4.1.50.3.1.1.1.16 integer read-write
Enable for the Beacon Isolation Algorithm. When this variable is set to enable, then if the ring beacons and is unable to recover itself, the MAU will execute the Beacon Isolation Algorithm. This algorithm will attempt to isolate the problem in the ring to a single port. This algorithm should ONLY be enabled if all MAU's in the ring are ODS MAU's with in-band agents that also have enbBcnIsoAlg set to enable. NOTE: this should be set to disable for all MAU's in the ring if any of the in-band agents has control of an MAU that has multiple rings. Enumeration: 'enable': 1, 'disable': 2.
                   trCards 1.3.6.1.4.1.50.3.1.1.2
                       cardNumSlots 1.3.6.1.4.1.50.3.1.1.2.1 integer read-only
The number of slots in the concentrator. For modular concentrators, this value is the maximum number of cards that can be installed. For non-modular concentrators, the value is always one.
                       cardNumCards 1.3.6.1.4.1.50.3.1.1.2.2 integer read-only
The number of cards actually installed in the concentrator. For non-modular concentrators, the value is always one.
                       cardTable 1.3.6.1.4.1.50.3.1.1.2.3 no-access
A list of card entries for each card installed in the concentrator. The number of entries is given by the value of CardNumCards.
                           cardEntry 1.3.6.1.4.1.50.3.1.1.2.3.1 no-access
A card entry containing objects pertaining to a card installed in the concentrator.
                               cardBypass 1.3.6.1.4.1.50.3.1.1.2.3.1.1 integer read-write
The current bypass state of the card. Enumeration: 'bypassOn': 1, 'unavailable': 3, 'bypassOff': 2.
                               cardRingStar 1.3.6.1.4.1.50.3.1.1.2.3.1.2 integer read-write
The Ring/Star mode of the card. Enumeration: 'starMode': 1, 'ringMode': 2, 'unavailable': 3.
                               cardRingSpeed 1.3.6.1.4.1.50.3.1.1.2.3.1.3 integer read-only
The Ring Speed of the card. Enumeration: 'speed4MHz': 2, 'speed16MHz': 1, 'unavailable': 3.
                               cardCableType 1.3.6.1.4.1.50.3.1.1.2.3.1.4 integer read-write
The card's Cable Type. Enumeration: 'type1': 2, 'unavailable': 3, 'type3': 1.
                               cardReset 1.3.6.1.4.1.50.3.1.1.2.3.1.6 integer read-only
The card's Reset Switch state. Enumeration: 'on': 1, 'off': 2, 'unavailable': 3.
                               cardSwitch 1.3.6.1.4.1.50.3.1.1.2.3.1.7 integer read-only
The state of the HW/SW switch on the card. Enumeration: 'sw': 1, 'hw': 2, 'unavailable': 3.
                               cardControl 1.3.6.1.4.1.50.3.1.1.2.3.1.8 integer read-only
Who currently controls the card, HW or SW. Enumeration: 'sw': 1, 'hw': 2, 'unavailable': 3.
                               cardId 1.3.6.1.4.1.50.3.1.1.2.3.1.9 integer read-only
The type of card installed in the concentrator. If the chassis is a modular chassis, then cardId defines the type of card. However, if the chassis is an 841 or 861 type chassis, then boxChassisId fully defines the type of card installed, so for a non-modular chassis the cardId specifies the Revision level. Enumeration: 'ods290-DB910port': 237, 'ods290-386-20RM': 42, 'revA': 1, 'ods290-ringint': 251, 'revC': 3, 'revB': 2, 'ods290-ATR50': 125, 'ods290-ATRJ16port': 126, 'ods290-FO10port': 31, 'ods290-12port': 239, 'ods290-386-20Bridge': 41, 'ods290-RMringmgr': 45.
                               cardIndex 1.3.6.1.4.1.50.3.1.1.2.3.1.10 integer read-only
The slot in which the card is installed. This value uniquely identifies the card. Its value ranges between 1 and the value of CardNumSlots.
                               cardDescrip 1.3.6.1.4.1.50.3.1.1.2.3.1.11 displaystring read-only
A textual description of the card including the ODS model number, media type and number of ports.
                               cardNumPorts 1.3.6.1.4.1.50.3.1.1.2.3.1.12 integer read-only
The number of configurable ports on the card. For some cards, the value may be zero.
                               cardHasPorts 1.3.6.1.4.1.50.3.1.1.2.3.1.13 integer read-only
This value describes if there are configurable user ports on the card. Enumeration: 'hasUserPorts': 1, 'noUserPorts': 2.
                               cardHasRingInt 1.3.6.1.4.1.50.3.1.1.2.3.1.14 integer read-only
This value describes if the card has ring in and ring out ports. Enumeration: 'hasRingPorts': 1, 'noRingPorts': 2.
                               cardHasTW 1.3.6.1.4.1.50.3.1.1.2.3.1.15 integer read-only
This value describes if the card's user ports are twisted wire or not. Enumeration: 'noTW': 2, 'hasTW': 1.
                               cardHasCtrl 1.3.6.1.4.1.50.3.1.1.2.3.1.16 integer read-only
This value describes if the card has a HW/SW Control switch or not. Enumeration: 'hasCtrl': 1, 'noCtrl': 2.
                               cardHasBypass 1.3.6.1.4.1.50.3.1.1.2.3.1.17 integer read-only
This value describes if the card has a Bypass switch or not. Enumeration: 'hasBypass': 1, 'noBypass': 2.
                   trPorts 1.3.6.1.4.1.50.3.1.1.3
                       portTable 1.3.6.1.4.1.50.3.1.1.3.1 no-access
A list of port entries for each interface port in the concentrator. The number of entries is given by the sum of CardNumPorts for each card in the CardTable.
                           portEntry 1.3.6.1.4.1.50.3.1.1.3.1.1 no-access
A port entry containing objects pertaining to an interface port in the concentrator.
                               portEnable 1.3.6.1.4.1.50.3.1.1.3.1.1.1 integer read-write
The current enable status of the port. If the value is off(2), no data is passed through the port. Enumeration: 'on': 1, 'off': 2.
                               portActStatus 1.3.6.1.4.1.50.3.1.1.3.1.1.2 integer read-only
Whether we currently see activity on the port. If we have activity, then the value is true(1). Enumeration: 'true': 1, 'false': 2.
                               portRingInsert 1.3.6.1.4.1.50.3.1.1.3.1.1.3 integer read-only
Whether someone is currently inserted onto the ring through this port. If true(1), then someone is inserted onto this port. Enumeration: 'true': 1, 'false': 2.
                               portDeinCount 1.3.6.1.4.1.50.3.1.1.3.1.1.4 counter read-write
Current count of successive deinserts that occurred on this port, each within MaxDeinDelta of the previous deinsert.
                               portCard 1.3.6.1.4.1.50.3.1.1.3.1.1.5 integer read-only
The card on which the port exists. The card identified by this value is the same card as identified by the same value of CardIndex.
                               portIndex 1.3.6.1.4.1.50.3.1.1.3.1.1.6 integer read-only
An integer which uniquely identifes this port on the card. Its value ranges between 1 and the value of CardNumPorts for the card.
                   trRing 1.3.6.1.4.1.50.3.1.1.4
                       ringportTable 1.3.6.1.4.1.50.3.1.1.4.1 no-access
A list of entries for Ring In and Ring Out ports of the concentrator.
                           ringEntry 1.3.6.1.4.1.50.3.1.1.4.1.1 no-access
A ring port entry containing objects pertaining the concentrator's Ring In and Ring Out ports.
                               rpMode 1.3.6.1.4.1.50.3.1.1.4.1.1.1 integer read-write
The current status of the ring port. Enumeration: 'internalLoop': 2, 'autoLoop': 1, 'normal': 3.
                               rpFOTW 1.3.6.1.4.1.50.3.1.1.4.1.1.2 integer read-write
Whether fiber optic or twisted wire are currently being used by the ring port. Enumeration: 'twistedWire': 2, 'fiberOptic': 1.
                               rpLoopBack 1.3.6.1.4.1.50.3.1.1.4.1.1.3 integer read-only
Whether the concentrator's ring port is in loopback mode. Enumeration: 'loopBackOn': 1, 'noLoopBack': 2.
                               rpVoltSense 1.3.6.1.4.1.50.3.1.1.4.1.1.4 integer read-only
Whether voltage is being sensed across the ring port. Enumeration: 'voltSenseOn': 1, 'noVoltSense': 2.
                               rpActStatus 1.3.6.1.4.1.50.3.1.1.4.1.1.5 integer read-only
Whether we currently see activity on the port. if we have activity, then the value is true(1). Enumeration: 'true': 1, 'false': 2.
                               rpCarrSense 1.3.6.1.4.1.50.3.1.1.4.1.1.6 integer read-only
Whether a carrier is sensed on the ring port. Enumeration: 'carrSenseOn': 1, 'noCarrSense': 2.
                               rpCard 1.3.6.1.4.1.50.3.1.1.4.1.1.7 integer read-only
The card on which the ring ports exist. The card identified by this value is the same card as identified by the same value of CardIndex.
                               rpIndex 1.3.6.1.4.1.50.3.1.1.4.1.1.8 integer read-only
An integer which uniquely identifies this ring port on the card. Its value ranges between 1 (Ring In) and 2 (Ring Out). Enumeration: 'ringInPort': 1, 'ringOutPort': 2.
                               rpHasTW 1.3.6.1.4.1.50.3.1.1.4.1.1.9 integer read-only
Whether or not the ring port has Twisted Wire. Enumeration: 'true': 1, 'false': 2.
                   trTrapEnable 1.3.6.1.4.1.50.3.1.1.5
                       teLoopBack 1.3.6.1.4.1.50.3.1.1.5.1 integer read-write
The Loopback state for a ring port has changed. This trap will be sent to the defined management station(s) if the value of teLoopBack enabled(1). Enumeration: 'disabled': 2, 'enabled': 1.
                       teMode 1.3.6.1.4.1.50.3.1.1.5.2 integer read-write
The state of the Ring Port mode switch has changed (Normal, Internal Loop, Auto Loop). This trap will be sent to the defined management station(s) if the value of teMode is enabled(1). Enumeration: 'disabled': 2, 'enabled': 1.
                       teFOTW 1.3.6.1.4.1.50.3.1.1.5.3 integer read-write
The state of the Fiber Optic/Twisted Wire switch has changed. This trap will be sent to the defined management station(s) if the value of teFOTW is enabled(1). Enumeration: 'disabled': 2, 'enabled': 1.
                       teRingInsert 1.3.6.1.4.1.50.3.1.1.5.4 integer read-write
A user was inserted onto the ring or de-inserted from the ring. This trap will be sent to the defined management station(s) if the value of teRingInsert is enabled(1). Enumeration: 'disabled': 2, 'enabled': 1.
                       teDeinCount 1.3.6.1.4.1.50.3.1.1.5.5 integer read-write
The De-insert count for one of the user ports is now greater than 1. This trap will be sent to the defined management station(s) if the value of teDeinCount is enabled(1). Enumeration: 'disabled': 2, 'enabled': 1.
                       teEnable 1.3.6.1.4.1.50.3.1.1.5.6 integer read-write
The state of one of the user port switches has changed. This trap will be sent to the defined management station(s) if the value of teEnable is enabled(1). Enumeration: 'disabled': 2, 'enabled': 1.
                       teBypass 1.3.6.1.4.1.50.3.1.1.5.7 integer read-write
The state of the Bypass control switch has changed. This trap will be sent to the defined management station(s) if the value of teBypass is enabled(1). Enumeration: 'disabled': 2, 'enabled': 1.
                       teRingStar 1.3.6.1.4.1.50.3.1.1.5.8 integer read-write
The state of the Ring/Star control switch has changed. This trap will be sent to the defined management station(s) if the value of teRingStar is enabled(1). Enumeration: 'disabled': 2, 'enabled': 1.
                       teRingSpeed 1.3.6.1.4.1.50.3.1.1.5.9 integer read-write
The state of the Ring Speed (Clock) control switch has changed. This trap will be sent to the defined management station(s) if the value of te_4_16 is enabled(1). Enumeration: 'disabled': 2, 'enabled': 1.
                       teCableType 1.3.6.1.4.1.50.3.1.1.5.10 integer read-write
The state of the Cable Type control switch has changed. This trap will be sent to the defined management station(s) if the value of teCableType is enabled(1). Enumeration: 'disabled': 2, 'enabled': 1.
                       teSwitch 1.3.6.1.4.1.50.3.1.1.5.12 integer read-write
The state of the HW/SW control switch has changed. This trap will be sent to the defined management station(s) if the value of teSwitch is enabled(1). Enumeration: 'disabled': 2, 'enabled': 1.
                       teLanManager 1.3.6.1.4.1.50.3.1.1.5.15 integer read-write
The Ringin or Ringout has gone into Loopback. This alert will be sent to IBM's Lan Manager management station(s) if the value of teLanManager is enabled(1). Enumeration: 'disabled': 2, 'enabled': 1.
               trAdmin 1.3.6.1.4.1.50.3.1.2
       trBridge 1.3.6.1.4.1.50.4