Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 occamMltMib 1.3.6.1.4.1.6066.2.1.1.3
This mib module describes objects used to perform Metallic Line Testing on customer access lines and to provide results.
     mltTestConfig 1.3.6.1.4.1.6066.2.1.1.3.1
         mltTestIdentifier 1.3.6.1.4.1.6066.2.1.1.3.1.1 mlttestidentifier read-write
Selects the mlt test to be run. Setting this value starts a test. This is a required parameter. Approximate expected test durations are as follows: statusSuite 1 second mltSuite 1 minute activeModeVoltages 3 seconds highImpedanceModeVoltages 9 seconds dcResistance 18 seconds capacitance 18 seconds loopDetect 9 seconds loopLength 9 seconds.
         mltTestType 1.3.6.1.4.1.6066.2.1.1.3.1.2 mlttesttype read-write
Selects if a test is requested (only run if port is not in use) or forced. This is an optional parameter. If not specified, the request option is used.
         mltTestPort 1.3.6.1.4.1.6066.2.1.1.3.1.3 integer32 read-write
Selects voice channel on which test will be run. This is a required parameter.
         mltDcResistanceRange 1.3.6.1.4.1.6066.2.1.1.3.1.4 integer32 read-write
Selects DC Resistance range value. This is an optional paramater. Default is 0 (auto mode).
         mltLoopLengthMultiplier 1.3.6.1.4.1.6066.2.1.1.3.1.5 integer32 read-write
Selects loop length multiplier in nf. This is an optional parameter. If not specified an internal default value of 83nF/mile is used.
         mltLoopDetectThreshold 1.3.6.1.4.1.6066.2.1.1.3.1.6 integer32 read-write
Selects the detection threshold in nF. This is an optional parameter. If not supplied, a loop detection threshold of 10nF is used.
     mltTestStatus 1.3.6.1.4.1.6066.2.1.1.3.2
         mltLastTestStatus 1.3.6.1.4.1.6066.2.1.1.3.2.1 mltteststatus read-only
Indicates the status of the last run mlt test. Given that the various mlt tests take several seconds to 1 1/2 minutes to run, it is suggested that status polls be spaced 10-20 seconds apart. Additionally, a monitoring application could wait for the testComplete notification.
         mltErrorText 1.3.6.1.4.1.6066.2.1.1.3.2.2 octet string read-only
Indicates the textual error in the case of an aborted test.
     mltTestResults 1.3.6.1.4.1.6066.2.1.1.3.3
         mltStatusResultsTable 1.3.6.1.4.1.6066.2.1.1.3.3.1 no-access
This table provides result of the status test suite.
             mltStatusResultsEntry 1.3.6.1.4.1.6066.2.1.1.3.3.1.1 no-access
Entry holding information about results of status suite tests. Note that a numerical result value of -999 means that there was an error of some sort and the value could not be measured.
                 mltStatusAlarm 1.3.6.1.4.1.6066.2.1.1.3.3.1.1.1 octet string read-only
Indicates GNK and/or OTEMP alarms active when status test was run.
                 mltStatusHookState 1.3.6.1.4.1.6066.2.1.1.3.3.1.1.2 mlttesthookstate read-only
Indicates line hook state when status test was run.
                 mltStatusTransversalCurrent 1.3.6.1.4.1.6066.2.1.1.3.3.1.1.3 integer32 read-only
Indicates transversal current when status test was run.
                 mltStatusLongitudinalCurrent 1.3.6.1.4.1.6066.2.1.1.3.3.1.1.4 integer32 read-only
Indicates Longitudinal current when status test was run.
                 mltStatusTipVoltage 1.3.6.1.4.1.6066.2.1.1.3.3.1.1.5 integer32 read-only
Indicates tip voltage when status test was run.
                 mltStatusRingVoltage 1.3.6.1.4.1.6066.2.1.1.3.3.1.1.6 integer32 read-only
Indicates ring voltage when status test was run.
                 mltStatusTipRingVoltage 1.3.6.1.4.1.6066.2.1.1.3.3.1.1.7 integer32 read-only
Indicates tip-ring voltage when status test was run.
                 mltStatusVdd 1.3.6.1.4.1.6066.2.1.1.3.3.1.1.8 integer32 read-only
Indicates Vdd when status test was run.
         mltTestResultsTable 1.3.6.1.4.1.6066.2.1.1.3.3.2 no-access
This table provides result of the mlt test suite. Note that a numerical result value of -999 means that there was an error of some sort and the value could not be measured. Also, a resistance value of 9999 means that the result was greater than 1000 kOhms, but the exact value could not be measured.
             mltTestResultsEntry 1.3.6.1.4.1.6066.2.1.1.3.3.2.1 no-access
Entry holding information about results of mlt suite tests.
                 mltTestAlarm 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.1 octet string read-only
GNK and OTEMP bits set by the DuSLIC will be reported as alarms. GNK is typically cause by ground fault or foreign voltage condition. OTEMP is set when the DuSLIC is experiencing thermal overload. This parameter is non-intrusive.
                 mltTestHookState 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.2 mlttesthookstate read-only
Hook state reflects the DuSLIC hook bit (offhook/onhook). This parameter is non-intrusive.
                 mltTestVdd 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.3 integer32 read-only
On HDPOTS, internal Voltage VDD will be reported and compared to statistically derived thresholds. This parameter is intrusive during offhook but will be available during onhook.
                 mltTestActiveModeVoltagesVdctr 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.4 integer32 read-only
Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only.
                 mltTestActiveModeVoltagesVdctg 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.5 integer32 read-only
Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only.
                 mltTestActiveModeVoltagesVdcrg 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.6 integer32 read-only
Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only.
                 mltTestActiveModeVoltagesVactr 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.7 integer32 read-only
Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. Thus, VT and VR measurements should be 0 volt. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only.
                 mltTestActiveModeVoltagesVactg 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.8 integer32 read-only
Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. Thus, VT and VR measurements should be 0 volt. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only.
                 mltTestActiveModeVoltagesVacrg 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.9 integer32 read-only
Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. Thus, VT and VR measurements should be 0 volt. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only.
                 mltTestHighImpedanceModeVoltagesVdctr 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.10 integer32 read-only
High Impedance Mode Tip/Ring DC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. DC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only.
                 mltTestHighImpedanceModeVoltagesVdctg 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.11 integer32 read-only
High Impedance Mode Tip/Ring DC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. DC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only.
                 mltTestHighImpedanceModeVoltagesVdcrg 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.12 integer32 read-only
High Impedance Mode Tip/Ring DC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. DC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only.
                 mltTestHighImpedanceModeVoltagesVactr 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.13 integer32 read-only
High Impedance Mode Tip/Ring AC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. AC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only.
                 mltTestHighImpedanceModeVoltagesVactg 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.14 integer32 read-only
High Impedance Mode Tip/Ring AC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. AC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only.
                 mltTestHighImpedanceModeVoltagesVacrg 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.15 integer32 read-only
High Impedance Mode Tip/Ring AC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. AC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only.
                 mltTestDcCurrentsItransversal 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.16 integer32 read-only
Four DC currents will be reported: IT, IL, It and Ir. In normal condition, currents will be measured in active mode. These measurements will not be available if alarm is present.
                 mltTestDcCurrentsIlongitudinal 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.17 integer32 read-only
Four DC currents will be reported: IT, IL, It and Ir. In normal condition, currents will be measured in active mode. These measurements will not be available if alarm is present.
                 mltTestDcCurrentsItip 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.18 integer32 read-only
Four DC currents will be reported: IT, IL, It and Ir. In normal condition, currents will be measured in active mode. These measurements will not be available if alarm is present.
                 mltTestDcCurrentsIring 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.19 integer32 read-only
Four DC currents will be reported: IT, IL, It and Ir. In normal condition, currents will be measured in active mode. These measurements will not be available if alarm is present.
                 mltTestCapacitanceCeqtr 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.20 integer32 read-only
Capacitance measurements will support only single element (2 terminal) circuit. In the presence of a network of capacitance (figure 3), the individual capacitance will not be resolved. The equivalent capacitances CEQtr, CEQtg and CEQrg will be reported. They represent the following: CEQtr = Ctr + Ctg/4 + Crg/4 CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg) CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg) Capacitance measurements will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only.
                 mltTestCapacitanceCeqtg 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.21 integer32 read-only
Capacitance measurements will support only single element (2 terminal) circuit. In the presence of a network of capacitance (figure 3), the individual capacitance will not be resolved. The equivalent capacitances CEQtr, CEQtg and CEQrg will be reported. They represent the following: CEQtr = Ctr + Ctg/4 + Crg/4 CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg) CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg) Capacitance measurements will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only.
                 mltTestCapacitanceCeqrg 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.22 integer32 read-only
Capacitance measurements will support only single element (2 terminal) circuit. In the presence of a network of capacitance (figure 3), the individual capacitance will not be resolved. The equivalent capacitances CEQtr, CEQtg and CEQrg will be reported. They represent the following: CEQtr = Ctr + Ctg/4 + Crg/4 CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg) CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg) Capacitance measurements will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only.
                 mltTestResistanceRtr 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.23 integer32 read-only
DC resistance measurements will be based on a 3 terminal circuit model. Rtr, Rtg and Rrg will be provided. User will have the option of specifying 3 resistance ranges: (1) low, (2) medium, (3) high. If not specified, auto mode will be used. Resistance measurements will not be available if fuse test fails or alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state ` only.
                 mltTestResistanceRtg 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.24 integer32 read-only
DC resistance measurements will be based on a 3 terminal circuit model. Rtr, Rtg and Rrg will be provided. User will have the option of specifying 3 resistance ranges: (1) low, (2) medium, (3) high. If not specified, auto mode will be used. Resistance measurements will not be available if fuse test fails or alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only.
                 mltTestResistanceRrg 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.25 integer32 read-only
DC resistance measurements will be based on a 3 terminal circuit model. Rtr, Rtg and Rrg will be provided. User will have the option of specifying 3 resistance ranges: (1) low, (2) medium, (3) high. If not specified, auto mode will be used. Resistance measurements will not be available if fuse test fails or alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only.
                 mltTestGr909HazardousPotentialTestResult 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.26 mlttestpassfail read-only
This test fails if the T-G or R-G ac voltage is greater than 50 volts rms or the T-G or R-G dc voltage is greater than 135 volts. This test will report pass/fail. This test is intrusive and will be available in shutdown state only.
                 mltTestGr909ForeignEmfTestResult 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.27 mlttestpassfail read-only
This test fails if the T-G or R-G ac voltage is greater than 50 volts rms or the T-G or R-G dc voltage is greater than 135 volts. This test will report pass/fail. This test is intrusive and will be available in shutdown state only.
                 mltTestGr909FuseTestTipFuse 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.28 mlttestpassfail read-only
This test determines if these fuses are blown. This test will return pass/fail for tip and ring. This test will not be performed if alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only. This object is obsolete. Object name was changed.
                 mltTestGr909FuseTestRingFuse 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.29 mlttestpassfail read-only
This test determines if these fuses are blown. This test will return pass/fail for tip and ring. This test will not be performed if alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only. This object is obsolete. Object name was changed.
                 mltTestGr909ResistiveFaultTestResult 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.30 mlttestpassfail read-only
This test fails if the T-R, T-G or R-G dc resistance is less than 150k ohm. This test will not be performed if fuse test fails or alarm is present. This test will return pass/fail. This test is intrusive and will be available in shutdown state only.
                 mltTestGr909ReceiverOffhookTestResult 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.31 mlttestpassfail read-only
This test fails if a non-linearity in the T-R dc resistance of greater than 15% when measured at two different voltage levels exists. This test will not be performed if fuse test fails or alarm is present. This test will return the DC resistances at two different operating points and the percent difference between the two DC resistances. This test is intrusive and will be available in shutdown state only.
                 mltTestGr909ReceiverOffhookTestResistance1 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.32 integer32 read-only
This test fails if a non-linearity in the T-R dc resistance of greater than 15% when measured at two different voltage levels exists. This test will not be performed if fuse test fails or alarm is present. This test will return the DC resistances at two different operating points and the percent difference between the two DC resistances. This test is intrusive and will be available in shutdown state only.
                 mltTestGr909ReceiverOffhookTestResistance2 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.33 integer32 read-only
This test fails if a non-linearity in the T-R dc resistance of greater than 15% when measured at two different voltage levels exists. This test will not be performed if fuse test fails or alarm is present. This test will return the DC resistances at two different operating points and the percent difference between the two DC resistances. This test is intrusive and will be available in shutdown state only.
                 mltTestGr909ReceiverOffhookTestDifference 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.34 integer32 read-only
This test fails if a non-linearity in the T-R dc resistance of greater than 15% when measured at two different voltage levels exists. This test will not be performed if fuse test fails or alarm is present. This test will return the DC resistances at two different operating points and the percent difference between the two DC resistances. This test is intrusive and will be available in shutdown state only.
                 mltTestGr909RingerTestResult 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.35 mlttestringerresult read-only
This test fails when the equivalent ringer count across tip and ring is less than 0.175 REN or greater than 5 REN. This test will not run if fuse test fails or alarm is present. This test will report passed/fail and the REN number. This parameter is intrusive and will be available in shutdown state shutdown only.
                 mltTestGr909RingerTestRen 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.36 integer32 read-only
This test fails when the equivalent ringer count across tip and ring is less than 0.175 REN or greater than 5 REN. This test will not run if fuse test fails or alarm is present. This test will report passed/fail and the REN number. This parameter is intrusive and will be available in shutdown state shutdown only.
                 mltTestErrors 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.37 octet string read-only
Indicates GNK and/or OTEMP alarms active when test was run.
                 mltTestFuseTestTipFuse 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.38 mlttestpassfail read-only
This test determines if these fuses are blown. This test will return pass/fail for tip and ring. This test will not be performed if alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only.
                 mltTestFuseTestRingFuse 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.39 mlttestpassfail read-only
This test determines if these fuses are blown. This test will return pass/fail for tip and ring. This test will not be performed if alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only.
         mltActiveModeVoltagesResultsTable 1.3.6.1.4.1.6066.2.1.1.3.3.3 no-access
This table provides results of the mlt active mode voltages test. Note that a numerical result value of -999 means that there was an error of some sort and the value could not be measured.
             mltActiveModeVoltagesResultsEntry 1.3.6.1.4.1.6066.2.1.1.3.3.3.1 no-access
Entry holding information about results of mlt active mode voltages test.
                 mltActiveModeVoltagesVdctr 1.3.6.1.4.1.6066.2.1.1.3.3.3.1.1 integer32 read-only
Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only.
                 mltActiveModeVoltagesVdctg 1.3.6.1.4.1.6066.2.1.1.3.3.3.1.2 integer32 read-only
Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only.
                 mltActiveModeVoltagesVdcrg 1.3.6.1.4.1.6066.2.1.1.3.3.3.1.3 integer32 read-only
Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only.
                 mltActiveModeVoltagesVactr 1.3.6.1.4.1.6066.2.1.1.3.3.3.1.4 integer32 read-only
Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. Thus, VT and VR measurements should be 0 volt. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only.
                 mltActiveModeVoltagesVactg 1.3.6.1.4.1.6066.2.1.1.3.3.3.1.5 integer32 read-only
Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. Thus, VT and VR measurements should be 0 volt. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only.
                 mltActiveModeVoltagesVacrg 1.3.6.1.4.1.6066.2.1.1.3.3.3.1.6 integer32 read-only
Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. Thus, VT and VR measurements should be 0 volt. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only.
                 mltActiveModeVoltagesErrors 1.3.6.1.4.1.6066.2.1.1.3.3.3.1.7 octet string read-only
Indicates GNK and/or OTEMP alarms active when test was run.
         mltHighImpedanceModeVoltagesResultsTable 1.3.6.1.4.1.6066.2.1.1.3.3.4 no-access
This table provides result of the mlt test suite. Note that a numerical result value of -999 means that there was an error of some sort and the value could not be measured.
             mltHighImpedanceModeVoltagesResultsEntry 1.3.6.1.4.1.6066.2.1.1.3.3.4.1 no-access
Entry holding information about results of mlt high impedance mode voltages test.
                 mltHighImpedanceModeVoltagesVdctr 1.3.6.1.4.1.6066.2.1.1.3.3.4.1.1 integer32 read-only
High Impedance Mode Tip/Ring DC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. DC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only.
                 mltHighImpedanceModeVoltagesVdctg 1.3.6.1.4.1.6066.2.1.1.3.3.4.1.2 integer32 read-only
High Impedance Mode Tip/Ring DC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. DC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only.
                 mltHighImpedanceModeVoltagesVdcrg 1.3.6.1.4.1.6066.2.1.1.3.3.4.1.3 integer32 read-only
High Impedance Mode Tip/Ring DC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. DC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only.
                 mltHighImpedanceModeVoltagesVactr 1.3.6.1.4.1.6066.2.1.1.3.3.4.1.4 integer32 read-only
High Impedance Mode Tip/Ring AC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. AC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only.
                 mltHighImpedanceModeVoltagesVactg 1.3.6.1.4.1.6066.2.1.1.3.3.4.1.5 integer32 read-only
High Impedance Mode Tip/Ring AC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. AC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only.
                 mltHighImpedanceModeVoltagesVacrg 1.3.6.1.4.1.6066.2.1.1.3.3.4.1.6 integer32 read-only
High Impedance Mode Tip/Ring AC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. AC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only.
                 mltHighImpedanceModeVoltagesErrors 1.3.6.1.4.1.6066.2.1.1.3.3.4.1.7 octet string read-only
Indicates GNK and/or OTEMP alarms active when test was run.
         mltDcResistanceResultsTable 1.3.6.1.4.1.6066.2.1.1.3.3.5 no-access
This table provides result of the DC resistance test. Note that a numerical result value of -999 means that there was an error of some sort and the value could not be measured. Also, a resistance value of 9999 means that the result was greater than 1000 kOhms, but the exact value could not be measured.
             mltDcResistanceResultsEntry 1.3.6.1.4.1.6066.2.1.1.3.3.5.1 no-access
Entry holding information about results of mlt DC resistance test.
                 mltDcResistanceRtr 1.3.6.1.4.1.6066.2.1.1.3.3.5.1.1 integer32 read-only
DC resistance measurements will be based on a 3 terminal circuit model. Rtr, Rtg and Rrg will be provided. User will have the option of specifying 3 resistance ranges: (1) low, (2) medium, (3) high. If not specified, auto mode will be used. Resistance measurements will not be available if fuse test fails or alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only.
                 mltDcResistanceRtg 1.3.6.1.4.1.6066.2.1.1.3.3.5.1.2 integer32 read-only
DC resistance measurements will be based on a 3 terminal circuit model. Rtr, Rtg and Rrg will be provided. User will have the option of specifying 3 resistance ranges: (1) low, (2) medium, (3) high. If not specified, auto mode will be used. Resistance measurements will not be available if fuse test fails or alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only.
                 mltDcResistanceRrg 1.3.6.1.4.1.6066.2.1.1.3.3.5.1.3 integer32 read-only
DC resistance measurements will be based on a 3 terminal circuit model. Rtr, Rtg and Rrg will be provided. User will have the option of specifying 3 resistance ranges: (1) low, (2) medium, (3) high. If not specified, auto mode will be used. Resistance measurements will not be available if fuse test fails or alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only.
                 mltDcResistanceErrors 1.3.6.1.4.1.6066.2.1.1.3.3.5.1.4 octet string read-only
Indicates GNK and/or OTEMP alarms active when test was run.
         mltCapacitanceResultsTable 1.3.6.1.4.1.6066.2.1.1.3.3.6 no-access
This table provides result of the mlt test suite. Note that a numerical result value of -999 means that there was an error of some sort and the value could not be measured.
             mltCapacitanceResultsEntry 1.3.6.1.4.1.6066.2.1.1.3.3.6.1 no-access
Entry holding information about results of mlt capacitance test.
                 mltCapacitanceCeqtr 1.3.6.1.4.1.6066.2.1.1.3.3.6.1.1 integer32 read-only
Capacitance measurements will support only single element (2 terminal) circuit. In the presence of a network of capacitance (figure 3), the individual capacitance will not be resolved. The equivalent capacitances CEQtr, CEQtg and CEQrg will be reported. They represent the following: CEQtr = Ctr + Ctg/4 + Crg/4 CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg) CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg) Capacitance measurements will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only.
                 mltCapacitanceCeqtg 1.3.6.1.4.1.6066.2.1.1.3.3.6.1.2 integer32 read-only
Capacitance measurements will support only single element (2 terminal) circuit. In the presence of a network of capacitance (figure 3), the individual capacitance will not be resolved. The equivalent capacitances CEQtr, CEQtg and CEQrg will be reported. They represent the following: CEQtr = Ctr + Ctg/4 + Crg/4 CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg) CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg) Capacitance measurements will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only.
                 mltCapacitanceCeqrg 1.3.6.1.4.1.6066.2.1.1.3.3.6.1.3 integer32 read-only
Capacitance measurements will support only single element (2 terminal) circuit. In the presence of a network of capacitance (figure 3), the individual capacitance will not be resolved. The equivalent capacitances CEQtr, CEQtg and CEQrg will be reported. They represent the following: CEQtr = Ctr + Ctg/4 + Crg/4 CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg) CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg) Capacitance measurements will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only.
                 mltCapacitanceErrors 1.3.6.1.4.1.6066.2.1.1.3.3.6.1.4 octet string read-only
Indicates GNK and/or OTEMP alarms active when test was run.
         mltLoopDetectResultsTable 1.3.6.1.4.1.6066.2.1.1.3.3.7 no-access
This table provides result of the mlt loop detect test. Note that a numerical result value of -999 means that there was an error of some sort and the value could not be measured.
             mltLoopDetectResultsEntry 1.3.6.1.4.1.6066.2.1.1.3.3.7.1 no-access
Entry holding information about results of mlt loop detect test.
                 mltLoopDetectLoopCapacitance 1.3.6.1.4.1.6066.2.1.1.3.3.7.1.1 integer32 read-only
Loop detection will be based on tip-ring capacitance measurement. User will be able to specify the detection threshold. If not supplied,loop detection threshold of 10 nF will be used. This test will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only.
                 mltLoopDetectDetectionThreshold 1.3.6.1.4.1.6066.2.1.1.3.3.7.1.2 integer32 read-only
Loop detection will be based on tip-ring capacitance measurement. User will be able to specify the detection threshold. If not supplied, loop detection threshold of 10 nF will be used. This test will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only.
                 mltLoopDetectLoopDetected 1.3.6.1.4.1.6066.2.1.1.3.3.7.1.3 mlttestyesno read-only
Loop detection will be based on tip-ring capacitance measurement. User will be able to specify the detection threshold. If not supplied, loop detection threshold of 10 nF will be used. This test will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only.
                 mltLoopDetectErrors 1.3.6.1.4.1.6066.2.1.1.3.3.7.1.4 octet string read-only
Indicates GNK and/or OTEMP alarms active when test was run.
         mltLoopLengthResultsTable 1.3.6.1.4.1.6066.2.1.1.3.3.8 no-access
This table provides result of the mlt loop length test. Note that a numerical result value of -999 means that there was an error of some sort and the value could not be measured.
             mltLoopLengthResultsEntry 1.3.6.1.4.1.6066.2.1.1.3.3.8.1 no-access
Entry holding information about results of mlt loop length test.
                 mltLoopLengthCapacitanceFactor 1.3.6.1.4.1.6066.2.1.1.3.3.8.1.1 integer32 read-only
Loop length estimate will be based on tip-ring capacitance measurement. User will be able to specify the loop length multiplier. If not supplied, loop length multiplier of 83 nF/ mile will be used. This test will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only.
                 mltLoopLengthLoopCapacitance 1.3.6.1.4.1.6066.2.1.1.3.3.8.1.2 integer32 read-only
Loop length estimate will be based on tip-ring capacitance measurement. User will be able to specify the loop length multiplier. If not supplied, loop length multiplier of 83 nF/ mile will be used. This test will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only.
                 mltLoopLengthLoopLength 1.3.6.1.4.1.6066.2.1.1.3.3.8.1.3 integer32 read-only
Loop length estimate will be based on tip-ring capacitance measurement. User will be able to specify the loop length multiplier. If not supplied, loop length multiplier of 83 nF/ mile will be used. This test will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only.
                 mltLoopLengthUncompensatedLoopCapacitance 1.3.6.1.4.1.6066.2.1.1.3.3.8.1.4 integer32 read-only
Loop length estimate will be based on tip-ring capacitance measurement. User will be able to specify the loop length multiplier. If not supplied, loop length multiplier of 83 nF/ mile will be used. This test will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only. This value has no DSL correction.
                 mltLoopLengthUncompensatedLoopLength 1.3.6.1.4.1.6066.2.1.1.3.3.8.1.5 integer32 read-only
Loop length estimate will be based on tip-ring capacitance measurement. User will be able to specify the loop length multiplier. If not supplied, loop length multiplier of 83 nF/ mile will be used. This test will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only. This value has no DSL correction.
                 mltLoopLengthErrors 1.3.6.1.4.1.6066.2.1.1.3.3.8.1.6 octet string read-only
Indicates GNK and/or OTEMP alarms active when test was run.
     mltTestNotifications 1.3.6.1.4.1.6066.2.1.1.3.4
         mltTestCompletedNotification 1.3.6.1.4.1.6066.2.1.1.3.4.1
This notification is sent to the requesting host when the requested mlt test has completed.