NTNTECH-INTERFACE-MODULE-CONFIGURATION-MIB: View SNMP OID List / Download MIB
VENDOR: NET TO NET TECHNOLOGIES
Home | MIB: NTNTECH-INTERFACE-MODULE-CONFIGURATION-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
ntntechInterfaceModuleConfigurationMIB | 1.3.6.1.4.1.8059.1.2.1 |
This mib module defines an SNMP API to manage Paradyne Corporation's IPD12000, IPD4000, and Mini/Micro DSLAM interface parameters. The interface types are described below, AMD8000-12 12-Port ADSL Mini DSLAMs With Full Rate and G.lite Operational Modes AAM8000-12 12-Port ADSL Access Multiplexer with Full Rate and G.lite Operational Modes AAM8000-24 24-Port ADSL Access Multiplexer with Full Rate and G.lite Operational Modes EAM2000-12 12-Port E1 Access Multiplexer TAM1500-12 12-Port T1 Access Multiplexer IAM144-12 12-Port IDSL Access Multiplexer SAM1000-12 12-Port SDSL Access Multiplexer SAM2000-12, SAM2000Q-12, and SAM2000G-12 12-Port SDSL Access Multiplexers with CAP, 2B1Q or TC/PAM (G.SHDSL) encoding SAM2000D-12 12-Port SDSL Access Multiplexer W/O voice daughter card, running CAP encoding SAM2000DQ-12 12-Port SDSL Access Multiplexer W/O voice daughter card, running 2B1Q encoding SAM2000V-12, SAM2000QV-12, SAM2000GV-12 12-Port SDSL Access Multiplexers with Voice Capability running CAP, 2B1Q or TC/PAM (G.SHDSL) encoding SIM2000-12 12-Port SDSL Access Multiplexer with CAP, 2B1Q and TC/PAM (G.SHDSL) encoding SIM2000-24 24-Port SDSL Access Multiplexer with CAP, 2B1Q and TC/PAM (G.SHDSL) encoding SMD2000-12, SMD2000Q-12, SMD2000G-12 12-Port SDSL Mini DSLAMs: AC and DC Versions with Cap, 2B1Q and G.SHDSL Line encoding SuD2011_12T, SuD2011_12E, SuD2003_12T, SuD2003_12E 12-Port SDSL Micro DSLAMs: Cap, 2B1Q and G.SHDSL Line encoding SuD2011_6T, SuD2011_6E, SuD2002_6T, SuD2002_6E 6-Port SDSL Micro DSLAMs: Cap, 2B1Q and G.SHDSL Line encoding |
||
ifModCfgMIBObjects | 1.3.6.1.4.1.8059.1.2.1.1 | |||
ifModCfgParameterConfiguration | 1.3.6.1.4.1.8059.1.2.1.1.1 | |||
prmCfgInterface | 1.3.6.1.4.1.8059.1.2.1.1.1.1 | |||
prmCfgInterfacePort | 1.3.6.1.4.1.8059.1.2.1.1.1.2 | |||
ifCfgPortTable | 1.3.6.1.4.1.8059.1.2.1.1.1.2.1 | no-access |
A list of IPD12000, IPD4000 Access/Inverse module and Mini/Micro DSLAM entries. |
|
1.3.6.1.4.1.8059.1.2.1.1.1.2.1.1 | no-access |
An entry containing management information applicable to the IPD12000, IPD4000 Access/Inverse module as well as the Mini/Micro DSLAM. |
||
ifCfgSlotIndex | 1.3.6.1.4.1.8059.1.2.1.1.1.2.1.1.1 | integer | read-only |
The physical slot number of the IPD chassis to which the interface module resides. The Mini/Micro DSLAM will have a slot index value of 1. |
ifCfgPortIndex | 1.3.6.1.4.1.8059.1.2.1.1.1.2.1.1.2 | integer | read-only |
The physical port number of the interface. |
ifCfgPortCircuitID | 1.3.6.1.4.1.8059.1.2.1.1.1.2.1.1.3 | octet string | read-write |
The circuit identification number assigned to a port on an interface. |
ifCfgPortFltrIp1Start | 1.3.6.1.4.1.8059.1.2.1.1.1.2.1.1.4 | ipaddress | read-write |
The value assigned to a port which designates the start of the first Ip filter range. |
ifCfgPortFltrIp1End | 1.3.6.1.4.1.8059.1.2.1.1.1.2.1.1.5 | ipaddress | read-write |
The value assigned to a port which designates the end of the first Ip filter range. |
ifCfgPortFltrIp2Start | 1.3.6.1.4.1.8059.1.2.1.1.1.2.1.1.6 | ipaddress | read-write |
The value assigned to a port which designates the start of the second Ip filter range. |
ifCfgPortFltrIp2End | 1.3.6.1.4.1.8059.1.2.1.1.1.2.1.1.7 | ipaddress | read-write |
The value assigned to a port which designates the end of the second Ip filter range. |
ifCfgPortBackboneVlan | 1.3.6.1.4.1.8059.1.2.1.1.1.2.1.1.8 | integer | read-write |
The Backbone VLAN tag will become the primary identifier that can be used by routers with backbone capabilities to direct traffic to the appropriate network cloud. |
ifCfgPortVlanPriority | 1.3.6.1.4.1.8059.1.2.1.1.1.2.1.1.9 | integer | read-write |
The value assigned to a port which designates the VLAN priority. |
ifCfgPortFloodMde | 1.3.6.1.4.1.8059.1.2.1.1.1.2.1.1.10 | integer | read-write |
The value assigned to a port which designates the flood mode. Enumeration: 'vlnFlood': 2, 'uplFlood': 1. |
ifCfgPortIpFltProtocol | 1.3.6.1.4.1.8059.1.2.1.1.1.2.1.1.11 | integer | read-write |
The value assigned to a port which designates the IP filter protocol. Enumeration: 'protocolIP': 2, 'protocolALL': 1. |
ifCfgPortReset | 1.3.6.1.4.1.8059.1.2.1.1.1.2.1.1.12 | integer | read-write |
This value is always read as integer value 2. Reset all associated port statistics to zero upon initiation of the reset(1). Enumeration: 'reset': 1, 'noReset': 2. |
ifCfgPortBkBoneEthType | 1.3.6.1.4.1.8059.1.2.1.1.1.2.1.1.13 | integer | read-write |
The value assigned to a port which designates the ethernet packet type. Enumeration: 'ethtype8100': 1, 'ethtype9100': 2. |
ifCfgPortVLANTable | 1.3.6.1.4.1.8059.1.2.1.1.1.2.2 | no-access |
A list of IPD12000, IPD4000 Access/Inverse module and Mini/Micro DSLAM port 802.1Q VLAN entries. |
|
1.3.6.1.4.1.8059.1.2.1.1.1.2.2.1 | no-access |
An entry containing management information applicable to an IPD12000, IPD4000 Access/Inverse module and Mini/Micro DSLAM port. |
||
ifCfgIfSlotIndex | 1.3.6.1.4.1.8059.1.2.1.1.1.2.2.1.1 | integer | read-only |
The physical slot number of the IPD chassis to which the interface module resides. The Mini/Micro slot index will be 1. |
ifCfgIfPortIndex | 1.3.6.1.4.1.8059.1.2.1.1.1.2.2.1.2 | integer | read-only |
The physical port number of the interface. |
ifCfgVLANIndex | 1.3.6.1.4.1.8059.1.2.1.1.1.2.2.1.3 | integer | read-only |
A pointer to one of ten possible VLAN tags that can be assigned to a port. |
ifCfgVLANIdStart | 1.3.6.1.4.1.8059.1.2.1.1.1.2.2.1.4 | integer | read-write |
The value assigned to a port which designates the start of a VLAN ID range. |
ifCfgVLANIdEnd | 1.3.6.1.4.1.8059.1.2.1.1.1.2.2.1.5 | integer | read-write |
The value assigned to a port which designates the end of a VLAN ID range. |
ifCfgPortAdslTable | 1.3.6.1.4.1.8059.1.2.1.1.1.2.3 | no-access |
A list of ADSL interface entries. |
|
1.3.6.1.4.1.8059.1.2.1.1.1.2.3.1 | no-access |
An entry containing management information applicable to ADSL module. |
||
ifCfgAdslSlotIndex | 1.3.6.1.4.1.8059.1.2.1.1.1.2.3.1.1 | integer | read-only |
The physical slot number of the IPD chassis to which the interface module resides. The Mini/Micro slot index will be 1. |
ifCfgAdslPortIndex | 1.3.6.1.4.1.8059.1.2.1.1.1.2.3.1.2 | integer | read-only |
The physical port number of the ADSL interface. |
ifCfgPortAdslPortMode | 1.3.6.1.4.1.8059.1.2.1.1.1.2.3.1.3 | integer | read-write |
The port mode of operation, ON, OFF, or Adaptive. When a port is set to Adaptive mode, the best possible value for the Rx/Tx data rates will be achieved. A successful data rate connection will be indicated with a port 'linkup' status. Enumeration: 'on': 1, 'adaptive': 3, 'off': 2, 'fixedadaptive': 4. |
ifCfgPortAdslVpiVciDetect | 1.3.6.1.4.1.8059.1.2.1.1.1.2.3.1.4 | integer | read-write |
ADSL Virtual Path Identifier (VPI) and Virtual Channel Identifier (VCI) detect mode. If this mode is set to ON, auto-detect the line VPI and VCI values. Enumeration: 'on': 1, 'off': 2. |
ifCfgPortAdslRxRate | 1.3.6.1.4.1.8059.1.2.1.1.1.2.3.1.5 | integer | read-write |
ADSL upstream (Rx) data rate. The available upstream data rates range from 32Kbps to 1024Kbps. The upstream data rate can be set by the user via the set value x where x = 1 to 32. The actual data rate that is represented by these set values can be calculated using the following formula, (x * 32Kbps) = upstream data rate, i.e. (3 * 32Kbps) = 96Kbps Note: if an Rx rate value of zero(0) is returned via a GET operation, this would indicate that the port is in 'Adaptive' mode and that the link condition is 'linkdown'. |
ifCfgPortAdslTxRate | 1.3.6.1.4.1.8059.1.2.1.1.1.2.3.1.6 | integer | read-write |
ADSL downstream (Tx) data rates. The available downstream data rates range from 32Kbps to 8064Kbps. The downstream data rate can be set by the user via the set value x where x = 1 to 252. The actual data rate that is represented by these set values can be calculated using the following formula, (x * 32Kbps) = downstream data rate, i.e. (252 * 32Kbps) = 8064Kbps Note: if a Tx rate value of zero(0) is returned via a GET operation, this would indicate that the port is in 'Adaptive' mode and that the link condition is 'linkdown'. |
ifCfgPortAdslFrameType | 1.3.6.1.4.1.8059.1.2.1.1.1.2.3.1.7 | integer | read-write |
ADSL frame type. Enumeration: 'frameType1483LLC': 1, 'frameType1483VCM': 2. |
ifCfgPortAdslVpi | 1.3.6.1.4.1.8059.1.2.1.1.1.2.3.1.8 | integer | read-write |
ADSL Virtual Path Identifier (VPI) value. |
ifCfgPortAdslVci | 1.3.6.1.4.1.8059.1.2.1.1.1.2.3.1.9 | integer | read-write |
ADSL Virtual Channel Identifier (VCI). |
ifCfgPortAdslStandardMde | 1.3.6.1.4.1.8059.1.2.1.1.1.2.3.1.10 | integer | read-write |
ADSL standard modes of operation. Note: if receive a standard mode of integer value 255 (0xFF), this would indicate that the standard mode is unknown due to a port 'linkdown' condition. Enumeration: 'gDMT-BISplus': 7, 'gDMT-BIS-Annex-M': 9, 'aLCATEL': 5, 'gDMT': 3, 't1413': 1, 'gDMT-BIS-Annex-L': 8, 'gLite': 2, 'stdMdeNoLink': 255, 'multiMode': 4, 'gDMT-BIS': 6. |
ifCfgPortAdslCorrectionUp | 1.3.6.1.4.1.8059.1.2.1.1.1.2.3.1.11 | integer | read-write |
ADSL Impulse protection duration in the Upstream duration. Enumeration: 'corr125us': 1, 'corr4ms': 6, 'corr500us': 3, 'corr2ms': 5, 'corr250us': 2, 'corr1ms': 4. |
ifCfgPortAdslCorrectionDn | 1.3.6.1.4.1.8059.1.2.1.1.1.2.3.1.12 | integer | read-write |
ADSL Impulse protection duration in the Upstream duration. Enumeration: 'corr125us': 1, 'corr4ms': 6, 'corr500us': 3, 'corr2ms': 5, 'corr250us': 2, 'corr1ms': 4. |
ifCfgPortAdslDelayUp | 1.3.6.1.4.1.8059.1.2.1.1.1.2.3.1.13 | integer | read-write |
ADSL Impulse protection duration in the Upstream direction. Enumeration: 'delay2ms': 2, 'delay1ms': 1, 'delay16ms': 5, 'delay8ms': 4, 'delay32ms': 6, 'delay64ms': 7, 'delay4ms': 3. |
ifCfgPortAdslDelayDn | 1.3.6.1.4.1.8059.1.2.1.1.1.2.3.1.14 | integer | read-write |
ADSL Impulse protection duration in the Upstream direction. Enumeration: 'delay2ms': 2, 'delay1ms': 1, 'delay16ms': 5, 'delay8ms': 4, 'delay32ms': 6, 'delay64ms': 7, 'delay4ms': 3. |
ifCfgPortAdslEcFdm | 1.3.6.1.4.1.8059.1.2.1.1.1.2.3.1.15 | integer | read-write |
ADSL Echo Cancellation uses Upstream Tones for Upstream and Dnstream data. Enumeration: 'fdm': 2, 'ec': 1. |
ifCfgPortAdslFastBuffer | 1.3.6.1.4.1.8059.1.2.1.1.1.2.3.1.16 | integer | read-write |
Selects fast buffer/low latency. Same is interleave delay of 1ms Enumeration: 'on': 1, 'off': 2. |
ifCfgPortAdslSnrUp | 1.3.6.1.4.1.8059.1.2.1.1.1.2.3.1.17 | integer | read-write |
Selects Target Upstream SNR |
ifCfgPortAdslSnrDn | 1.3.6.1.4.1.8059.1.2.1.1.1.2.3.1.18 | integer | read-write |
Selects Target Dnstream SNR |
ifCfgPortAdslActualRxRate | 1.3.6.1.4.1.8059.1.2.1.1.1.2.3.1.19 | integer | read-only |
ADSL upstream (Rx) data rate. The available upstream data rates range from 32Kbps to 1024Kbps. The upstream data rate can be set by the user via the set value x where x = 1 to 64. The actual data rate that is represented by these set values can be calculated using the following formula, (x * 32Kbps) = upstream data rate, i.e. (3 * 32Kbps) = 96Kbps Note: if an Rx rate value of zero(0) is returned via a GET operation, this would indicate that the port is in 'Adaptive' mode and that the link condition is 'linkdown'. |
ifCfgPortAdslActualTxRate | 1.3.6.1.4.1.8059.1.2.1.1.1.2.3.1.20 | integer | read-only |
ADSL downstream (Tx) data rates. The available downstream data rates range from 32Kbps to 8064Kbps. The downstream data rate can be set by the user via the set value x where x = 1 to 1024. The actual data rate that is represented by these set values can be calculated using the following formula, (x * 32Kbps) = downstream data rate, i.e. (252 * 32Kbps) = 8064Kbps Note: if a Tx rate value of zero(0) is returned via a GET operation, this would indicate that the port is in 'Adaptive' mode and that the link condition is 'linkdown'. |
ifCfgPortAdslActualStandardMde | 1.3.6.1.4.1.8059.1.2.1.1.1.2.3.1.21 | integer | read-only |
ADSL current operating mode, should match ifCfgPortAdslStandardMde UNLESS operating in MULTIMODE Enumeration: 'gDMT-BISplus': 7, 'gDMT-BIS-Annex-M': 9, 'aLCATEL': 5, 'gDMT': 3, 't1413': 1, 'gDMT-BIS-Annex-L': 8, 'gLite': 2, 'stdMdeNoLink': 255, 'multiMode': 4, 'gDMT-BIS': 6. |
ifCfgPortAdslActualDepthUp | 1.3.6.1.4.1.8059.1.2.1.1.1.2.3.1.22 | integer | read-only |
ADSL upstream interleving depth. |
ifCfgPortAdslActualDepthDn | 1.3.6.1.4.1.8059.1.2.1.1.1.2.3.1.23 | integer | read-only |
ADSL dnstream interleaving depth. |
ifCfgPortIdslTable | 1.3.6.1.4.1.8059.1.2.1.1.1.2.4 | no-access |
A list of IDSL interface entries. |
|
1.3.6.1.4.1.8059.1.2.1.1.1.2.4.1 | no-access |
An entry containing management information applicable to the IDSL interface. |
||
ifCfgIdslSlotIndex | 1.3.6.1.4.1.8059.1.2.1.1.1.2.4.1.1 | integer | read-only |
The physical slot number of the IPD chassis to which the interface module resides. The Mini/Micro slot index will be 1. |
ifCfgIdslPortIndex | 1.3.6.1.4.1.8059.1.2.1.1.1.2.4.1.2 | integer | read-only |
The physical port number of the IDSL interface. |
ifCfgPortIdslRxTxRate | 1.3.6.1.4.1.8059.1.2.1.1.1.2.4.1.3 | integer | read-write |
IDSL symetrical (Rx/Tx) data rates. IDSL module types and the associated Rx/Tx data rates- IAM144-12: Data Rates (Kbps): 128,144 Note: if a rate value of zero(0) is returned via a GET operation, it will indicate that the port is defective. Enumeration: 'idslRxTxRate144': 2, 'idslRxTxRate128': 1, 'idslRxTxRateOff': 255, 'idslRxTxRateDefect': 0. |
ifCfgPortSdslTable | 1.3.6.1.4.1.8059.1.2.1.1.1.2.5 | no-access |
A list of SDSL interface entries. |
|
1.3.6.1.4.1.8059.1.2.1.1.1.2.5.1 | no-access |
An entry containing management information applicable to the SDSL interface. |
||
ifCfgSdslSlotIndex | 1.3.6.1.4.1.8059.1.2.1.1.1.2.5.1.1 | integer | read-only |
The physical slot number of the IPD chassis to which the interface module resides. The Mini/Micro slot index will be 1. |
ifCfgSdslPortIndex | 1.3.6.1.4.1.8059.1.2.1.1.1.2.5.1.2 | integer | read-only |
The physical port number of the SDSL interface. |
ifCfgPortSdslRxTxRate | 1.3.6.1.4.1.8059.1.2.1.1.1.2.5.1.3 | integer | read-write |
SDSL symetrical (Rx/Tx) data rates. SDSL module types and the associated Rx/Tx data rates- SAM1000-12: Data Rates (Kbps): 272,528,784,1168 SAM2000-12,SAM2000Q-12,SAM2000G-12,SAM2000D-12,SAM2000DQ-12, SIM2000-24,SuD2011_12T,SuD2011_12E,SuD2003_12T,SuD2003_12E, SuD2011_6T,SuD2011_6E,SuD2002_6T,SuD2002_6E: Data Rates (Kbps): 144,272,400,528,784,1040,1552,2064,2320 SAM2000V-12,SAM2000QV-12,SAM2000GV-12,SIM2000V-12,SIM2000V-24: Data Rates (Kbps): 272,400,528,784,1040,1552,2064,2320 Note: if a rate value of zero(0) is returned via a GET operation, it will indicate that the port is defective. Enumeration: 'sdslRxTxRate272': 2, 'sdslRxTxRate1552': 8, 'sdslRxTxRate2064': 9, 'sdslRxTxRateOff': 255, 'sdslRxTxRate1040': 6, 'sdslRxTxRateDefect': 0, 'sdslRxTxRate2320': 10, 'sdslRxTxRate528': 4, 'sdslRxTxRate784': 5, 'sdslRxTxRate144': 1, 'sdslRxTxRate1168': 7, 'sdslRxTxRate400': 3. |
ifCfgPortSdslLineCode | 1.3.6.1.4.1.8059.1.2.1.1.1.2.5.1.4 | integer | read-write |
Line code for the SDSL modules. Note, the line code may be set on the following modules, SIM2000-12,SIM2000-24,SIM2000V-24,SIM2000V-12, or the SDSL micro DSLAM. The line code options are described as follows- CAP: Carrierless Amplitude and Phase modulation 2B1Q: Two Binary, One Quaternary G.SHDSL: Multirate Symmetric Single-pair DSL Enumeration: 'lineCodeGSHDSL': 3, 'lineCodeCap': 1, 'lineCode2B1Q': 2. |
ifCfgPortT1Table | 1.3.6.1.4.1.8059.1.2.1.1.1.2.6 | no-access |
A list of T1 interface entries. |
|
1.3.6.1.4.1.8059.1.2.1.1.1.2.6.1 | no-access |
An entry containing management information applicable to the T1 interface. |
||
ifCfgT1SlotIndex | 1.3.6.1.4.1.8059.1.2.1.1.1.2.6.1.1 | integer | read-only |
The physical slot number of the IPD chassis to which the interface module resides. The Mini/Micro slot index will be 1. |
ifCfgT1PortIndex | 1.3.6.1.4.1.8059.1.2.1.1.1.2.6.1.2 | integer | read-only |
The physical port number of the T1 interface. |
ifCfgPortT1RxTxRate | 1.3.6.1.4.1.8059.1.2.1.1.1.2.6.1.3 | integer | read-write |
T1 symetrical (Rx/Tx) data rates. T1 module types and the associated Rx/Tx data rates- TAM1500-12,TIM1500-12,TIM1500-24: Data Rates (Kbps): 192,384,576,768,960,1152,1344,1536 Note: if a rate value of zero(0) is returned via a GET operation, it will indicate that the port is defective. Enumeration: 't1RxTxRate384': 2, 't1RxTxRate1344': 7, 't1RxTxRate576': 3, 't1RxTxRateDefect': 0, 't1RxTxRate768': 4, 't1RxTxRateOff': 255, 't1RxTxRate192': 1, 't1RxTxRate960': 5, 't1RxTxRate1536': 8, 't1RxTxRate1152': 6. |
ifCfgPortT1FrameType | 1.3.6.1.4.1.8059.1.2.1.1.1.2.6.1.4 | integer | read-write |
T1 frame type. Enumeration: 't1frameTypeESF': 1, 't1frameTypeSFD4': 2. |
ifCfgPortT1LineCode | 1.3.6.1.4.1.8059.1.2.1.1.1.2.6.1.5 | integer | read-write |
T1 line code. Enumeration: 't1lineCodeB8ZS': 1, 't1lineCodeAMI': 2. |
ifCfgPortT1TxBuildOut | 1.3.6.1.4.1.8059.1.2.1.1.1.2.6.1.6 | integer | read-write |
T1 tx buildout. Enumeration: 't1TxBuildOutN15db': 3, 't1TxBuildOutN7p5db': 2, 't1TxBuildOut0db': 1, 't1TxBuildOutN22db': 4. |
ifCfgPortT1ClockSrc | 1.3.6.1.4.1.8059.1.2.1.1.1.2.6.1.7 | integer | read-write |
T1 clock source. Enumeration: 't1ClockSrcLoop': 2, 't1ClockSrcLocal': 1. |
ifCfgPortE1Table | 1.3.6.1.4.1.8059.1.2.1.1.1.2.7 | no-access |
A list of E1 interface entries. |
|
1.3.6.1.4.1.8059.1.2.1.1.1.2.7.1 | no-access |
An entry containing management information applicable to the E1 interface. |
||
ifCfgE1SlotIndex | 1.3.6.1.4.1.8059.1.2.1.1.1.2.7.1.1 | integer | read-only |
The physical slot number of the IPD chassis to which the interface module resides. The Mini/Micro slot index will be 1. |
ifCfgE1PortIndex | 1.3.6.1.4.1.8059.1.2.1.1.1.2.7.1.2 | integer | read-only |
The physical port number of the E1 interface. |
ifCfgPortE1RxTxRate | 1.3.6.1.4.1.8059.1.2.1.1.1.2.7.1.3 | integer | read-write |
E1 symetrical (Rx/Tx) data rates. E1 module types and the associated Rx/Tx data rates- EAM2000-12,EIM2000-12,EIM2000-24: Data Rates (Kbps): 256,512,768,1024,1280,1536,1792,1984 Note: if a rate value of zero(0) is returned via a GET operation, it will indicate that the port is defective. Enumeration: 'e1RxTxRate256': 1, 'e1RxTxRate1536': 6, 'e1RxTxRate512': 2, 'e1RxTxRate1280': 5, 'e1RxTxRate768': 3, 'e1RxTxRateOff': 255, 'e1RxTxRate1024': 4, 'e1RxTxRate1984': 8, 'e1RxTxRate1792': 7, 'e1RxTxRateDefect': 0. |
ifCfgPortE1FrameType | 1.3.6.1.4.1.8059.1.2.1.1.1.2.7.1.4 | integer | read-write |
E1 frame type. Enumeration: 'e1frameTypeNoCRC': 2, 'e1frameTypeCRC': 1. |
ifCfgPortE1LineCode | 1.3.6.1.4.1.8059.1.2.1.1.1.2.7.1.5 | integer | read-write |
E1 line code. Enumeration: 'e1lineCodeHDB3': 1, 'e1lineCodeAMI': 2. |
ifCfgPortE1ClockSrc | 1.3.6.1.4.1.8059.1.2.1.1.1.2.7.1.6 | integer | read-write |
E1 clock source. Enumeration: 'e1ClockSrcLocal': 1, 'e1ClockSrcLoop': 2. |