NSCRTV-ROOT: View SNMP OID List / Download MIB
VENDOR: NATIONAL STANDARDIZATION COMMITTEE OF RADIO AND TV
Home | MIB: NSCRTV-ROOT | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
nscrtvRoot | 1.3.6.1.4.1.17409 | |||
nscrtvHFCemsTree | 1.3.6.1.4.1.17409.1 | |||
propertyIdent | 1.3.6.1.4.1.17409.1.1 | |||
analogPropertyTable | 1.3.6.1.4.1.17409.1.1.1 | no-access |
Attribute Table simulation parameters |
|
1.3.6.1.4.1.17409.1.1.1.1 | no-access |
Attribute Table simulation parameters head. OID purpose as a table index,Its coding method is'length��OID'��OID former two members'1.3'According to '1'and'3'respectively coding,Instead of ordinary OID encoding (0x2B). |
||
analogParameterOID | 1.3.6.1.4.1.17409.1.1.1.1.1 | object identifier | read-only |
index |
alarmEnable | 1.3.6.1.4.1.17409.1.1.1.1.2 | octet string | read-write |
Alarm enable control byte, the corresponding position for the'1 'that allow alarm,'0' a ban warning Bit 0: Alarm enable low Bit 1: Alarm enable low Bit 2: Alarm enable high Bit 3: Alarm enable high Bit 4 ~ 7 reservations should be 0 This object should be stored in nonvolatile memory. |
analogAlarmState | 1.3.6.1.4.1.17409.1.1.1.1.3 | integer | read-only |
The parameters of the current state of alarm. Enumeration: 'aasLOLO': 5, 'aasHI': 3, 'aasHIHI': 2, 'aasLO': 4, 'aasNominal': 1. |
analogAlarmHIHI | 1.3.6.1.4.1.17409.1.1.1.1.4 | integer | read-write |
Alarm HIHI high threshold value. This object should be stored in non-volatile memory. |
analogAlarmHI | 1.3.6.1.4.1.17409.1.1.1.1.5 | integer | read-write |
HI high alarm threshold value. This object should be stored in non-volatile memory. |
analogAlarmLO | 1.3.6.1.4.1.17409.1.1.1.1.6 | integer | read-write |
LO low alarm threshold value. This object should be stored in non-volatile memory. |
analogAlarmLOLO | 1.3.6.1.4.1.17409.1.1.1.1.7 | integer | read-write |
Alarm LOLO very low threshold value. This object should be stored in non-volatile memory. |
analogAlarmDeadband | 1.3.6.1.4.1.17409.1.1.1.1.8 | integer | read-write |
Dead-alarm threshold value. After the warning, parameter values should be restored to the alarm threshold and alarm threshold and the difference between the absolute value greater than the value of dead zone, the alarm can be removed. This object should be stored in nonvolatile memory. |
discretePropertyTable | 1.3.6.1.4.1.17409.1.1.2 | no-access |
Discrete Attribute Table. |
|
1.3.6.1.4.1.17409.1.1.2.1 | no-access |
Attribute Table discrete head. OID coding methods with simulation attribute table |
||
discreteParameterOID | 1.3.6.1.4.1.17409.1.1.2.1.1 | object identifier | read-only |
Attribute Table discrete index 1: Parameters OID. |
discreteAlarmValue | 1.3.6.1.4.1.17409.1.1.2.1.2 | integer | read-only |
Attribute Table discrete index 2: parameter values. When the equipment value of this parameter values, and so will be dealt with a warning. |
discreteAlarmEnable | 1.3.6.1.4.1.17409.1.1.2.1.3 | integer | read-write |
When the alarm so that it can open the (2 or 3), this parameter allows for alarm processing. If the alarm so that it can shut down (1), alarm processing will be carried out. This object default values for the disable (1). This object should be stored in non-volatile memory. Enumeration: 'enableMinor': 3, 'disable': 1, 'enableMajor': 2. |
discreteAlarmState | 1.3.6.1.4.1.17409.1.1.2.1.4 | integer | read-only |
The parameters of the current state of alarm. Enumeration: 'dasDiscreteMinor': 7, 'dasNominal': 1, 'dasDiscreteMajor': 6. |
currentAlarmTable | 1.3.6.1.4.1.17409.1.1.3 | no-access |
The current warning Table. |
|
1.3.6.1.4.1.17409.1.1.3.1 | no-access |
The current warning Table Head. OID coding methods with simulation attribute table. |
||
currentAlarmOID | 1.3.6.1.4.1.17409.1.1.3.1.1 | object identifier | read-only |
NE, currently in a state of alarm parameters OID Index, and attribute the alarm in the table corresponding parameters OID. |
currentAlarmState | 1.3.6.1.4.1.17409.1.1.3.1.2 | integer | read-only |
Warning parameters of the current state of alarm. Enumeration: 'caasLO': 4, 'caasLOLO': 5, 'caasDiscreteMajor': 6, 'caasDiscreteMinor': 7, 'caasHI': 3, 'caasHIHI': 2. |
currentAlarmValue | 1.3.6.1.4.1.17409.1.1.3.1.3 | integer | read-only |
Alarm parameter's value. |
alarmsIdent | 1.3.6.1.4.1.17409.1.2 | |||
alarmLogNumberOfEntries | 1.3.6.1.4.1.17409.1.2.1 | integer | read-only |
Alarm record number of records in the table. |
alarmLogLastIndex | 1.3.6.1.4.1.17409.1.2.2 | integer | read-only |
Recently a warning the index of the records. |
alarmLogTable | 1.3.6.1.4.1.17409.1.2.3 | no-access |
Alarm record form, at least support 16 record. Each table in the registration of a new record, the management agent (transponder) managers should send traps news. |
|
1.3.6.1.4.1.17409.1.2.3.1 | no-access |
Alarm Sheet Head. |
||
alarmLogIndex | 1.3.6.1.4.1.17409.1.2.3.1.1 | integer | read-only |
The only logo Alarm Index recorded a record in the table, the index value increased from 1 start of each new record, plus 1 until 32,767, a record index of the re-starts at 1. Acting under the management of storage capacity can be the first choice to delete those records, the specific details in this not to achieve provisions. |
alarmLogInformation | 1.3.6.1.4.1.17409.1.2.3.1.2 | octet string | read-only |
Alarm record information, multi-byte strings, defined as follows: Byte 1 ~ 4: Alarm in time (POSIX format, the previous maximum byte) Byte 5: Alarm types (enumeration, definitions see behind) Byte 6: Alarm value after commonNeStatus Byte 7 ~ m: Alarm parameters object identifier (Basic Encoding Rules (ASN.1)) Byte n ~ z: Alarm parameter values (Basic Encoding Rules (ASN.1)) Alarm enumerated types: 1 NOMINAL 2 HIHI 3 HI 4 LO 5 LOLO 6 Discrete Major 7 Discrete Minor |
alarmText | 1.3.6.1.4.1.17409.1.2.4 | displaystring | no-access |
This trap targets for the needs of information contained in a text field transponder information is achievable. The field contains the text of the object depends on the definition of alarm parameters, it is uncertain, This object can not access provisions. |
commonIdent | 1.3.6.1.4.1.17409.1.3 | |||
commonAdminGroup | 1.3.6.1.4.1.17409.1.3.1 | |||
commonNELogicalID | 1.3.6.1.4.1.17409.1.3.1.1 | octet string | read-write |
The logic of the designated NE identifier (LogicID), the values and attributes of other unrelated NE. This target value should be stored in non-volatile memory. |
commonNEVendor | 1.3.6.1.4.1.17409.1.3.1.2 | displaystring | read-only |
NE equipment manufacturers. |
commonNEModelNumber | 1.3.6.1.4.1.17409.1.3.1.3 | displaystring | read-only |
NE equipment models. |
commonNESerialNumber | 1.3.6.1.4.1.17409.1.3.1.4 | displaystring | read-only |
NE equipment serial numbers. |
commonNEVendorInfo | 1.3.6.1.4.1.17409.1.3.1.5 | displaystring | read-only |
NE equipment suppliers other special designated information. |
commonNEStatus | 1.3.6.1.4.1.17409.1.3.1.6 | octet string | read-only |
With 7.5.4 STATRESP PDU parameters in the corresponding Status Bit 0: CHNLRQST Bit 1: CNTNRM Bit 2: CNTCUR Bit 3: MAJOR ALARMS Bit 4: MINOR ALARMS Bit 5: RSVD1 Bit 6: RSVD2 Bit 7: RSVD3 |
commonReset | 1.3.6.1.4.1.17409.1.3.1.7 | integer | read-write |
Write'1 'will be reset NE equipment, the value will be included in other non-functional. Reading this object return value'1 ', had no effect on equipment. Enumeration: 'reset': 1. |
commonAlarmDetectionControl | 1.3.6.1.4.1.17409.1.3.1.8 | integer | read-write |
This object used to control the Alarm Detection NE. Enumeration: 'detectionDisabled': 1, 'detectionEnabled': 2, 'detectionEnabledAndRegenerate': 3. |
commonNetworkAddress | 1.3.6.1.4.1.17409.1.3.1.9 | ipaddress | read-only |
NE network IP address, NE produce Trap should include this address. This value should be stored in nonvolatile memory. This value can be registered through the MAC order or through local vendors to set up Interface. |
commonCheckCode | 1.3.6.1.4.1.17409.1.3.1.10 | integer | read-write |
This target for the detection transponder code configuration of the report. The calculation includes detection code transponder (including management equipment) and the physical configuration parameters stored in non-volatile memory of all the parameters. The detection algorithm calculated by the vendor code provisions. The object should be kept in the value of non-volatile memory, the response thinks highly activated, will be recalculated and re-testing code and the value prior to the commencement of comparison to determine whether or should haveһ��hfcColdStart hfcWarmStart traps. When write this object (SetRequest), the detection code will be recalculated and fill the SetRequest in response to the GetResponse. At this time, will not produce or hfcWarmStart traps hfcColdStart. |
commonTrapCommunityString | 1.3.6.1.4.1.17409.1.3.1.11 | octet string | read-write |
Definition of Community Trap string. The default value is' public '. The value of this object should be stored in non-volatile memory. |
commonTamperStatus | 1.3.6.1.4.1.17409.1.3.1.12 | integer | read-only |
The safety report NE switching equipment (such as whether to open up the lid) state that this object is called discrete attributes of a corresponding entry in the table. Intact that normal, expressed alarm compromised. Enumeration: 'intact': 1, 'compromised': 2. |
commonInternalTemperature | 1.3.6.1.4.1.17409.1.3.1.13 | integer | read-only |
NE equipment Room (machine) temperature, units degrees Celsius. This request object attribute in a corresponding entry in the table. |
commonTime | 1.3.6.1.4.1.17409.1.3.1.14 | integer | read-write |
NE of the POSIX said that the current time (since at 0:00 on January 1, 1970 since the seconds). |
commonVarBindings | 1.3.6.1.4.1.17409.1.3.1.15 | integer | read-only |
This object can be said to receive SNMP information NE variables bundled the largest number of tables. Value: 0 indicated no restrictions on the maximum number bundled. |
commonResetCause | 1.3.6.1.4.1.17409.1.3.1.16 | integer | read-only |
NE said the reasons for the recent reduction. Enumeration: 'powerup': 2, 'watchdog': 4, 'craft': 5, 'other': 1, 'command': 3. |
commonCraftStatus | 1.3.6.1.4.1.17409.1.3.1.17 | integer | read-only |
NE local object that this interface (such as RS232 or RS485 interface) state. NE does not necessarily have to support the local interface. NE local interface without affecting the state of its MAC interface functions; If we do not support the local interface, and its value is disconnected. Enumeration: 'connected': 2, 'disconnected': 1. |
commonDeviceOID | 1.3.6.1.4.1.17409.1.3.1.18 | object identifier | read-only |
This OID object as a pointer, the equipment was used at MIB (such as Node, two-way amplifier, etc). |
commonDeviceId | 1.3.6.1.4.1.17409.1.3.1.19 | octet string | read-only |
The contents of this object by the designated by the equipment vendors, manufacturers and products it contains special ASCII text messages. |
commondownload | 1.3.6.1.4.1.17409.1.3.1.20 | integer | read-write |
Enumeration: 'reset': 1. |
commonAdminUseRf | 1.3.6.1.4.1.17409.1.3.2 | |||
commonMACGroup | 1.3.6.1.4.1.17409.1.3.2.1 | |||
commonMacAddress | 1.3.6.1.4.1.17409.1.3.2.1.1 | |||
commonPhysAddress | 1.3.6.1.4.1.17409.1.3.2.1.1.1 | octet string | read-only |
NE MAC (physical) address. |
commonMaxMulticastAddresses | 1.3.6.1.4.1.17409.1.3.2.1.1.2 | integer | read-only |
NE equipment to support the greatest number of multicast addresses. |
commonMulticastAddressTable | 1.3.6.1.4.1.17409.1.3.2.1.1.3 | no-access |
Multicast addresses Table, the value of this object should be stored in nonvolatile memory. |
|
1.3.6.1.4.1.17409.1.3.2.1.1.3.1 | no-access |
Multicast addresses Table Head. |
||
commonMulticastAddressIndex | 1.3.6.1.4.1.17409.1.3.2.1.1.3.1.1 | integer | read-only |
Multicast addresses Index. |
commonMulticastAddressNumber | 1.3.6.1.4.1.17409.1.3.2.1.1.3.1.2 | octet string | read-write |
Multicast addresses,I/Gbit |
commonBackoffParams | 1.3.6.1.4.1.17409.1.3.2.1.2 | |||
commonBackoffPeriod | 1.3.6.1.4.1.17409.1.3.2.1.2.1 | integer | read-write |
Backoff algorithm benchmark time (ms), initialize the default value of 6 ms. The value of this object should be stored in non-volatile memory. |
commonACKTimeoutWindow | 1.3.6.1.4.1.17409.1.3.2.1.2.2 | integer | read-write |
NE awaiting HE overtime to send ACK response time (ms), initialize the default value is 19 ms. The value of this object should be stored in non-volatile memory. |
commonMaximumMACLayerRetries | 1.3.6.1.4.1.17409.1.3.2.1.2.3 | integer | read-write |
NE data packets sent the greatest number of re-examination. Initialize the default value is 16. The value of this object should be stored in non-volatile memory. |
commonMaxPayloadSize | 1.3.6.1.4.1.17409.1.3.2.1.2.4 | integer | read-only |
From top to bottom line channel packet supported by the largest payload (payload) the length of. |
commonBackoffMinimumExponent | 1.3.6.1.4.1.17409.1.3.2.1.2.5 | integer | read-write |
The standards body of the MAC layer specification definition of the smallest backoff algorithm index value, default values for 6. This value may not exceed commonBackoffMaximumValue value. The value of this object should be stored in non-volatile memory. |
commonBackoffMaximumExponent | 1.3.6.1.4.1.17409.1.3.2.1.2.6 | integer | read-write |
The body of the MAC layer standard definition of backoff algorithm for standardizing the largest index value, the default value is 15. This value shall be not less than commonBackoffMinimum value. The value of this object should be stored in non-volatile memory. |
commonMacStats | 1.3.6.1.4.1.17409.1.3.2.1.3 | |||
commonForwardPathLOSEvents | 1.3.6.1.4.1.17409.1.3.2.1.3.1 | counter | read-write |
LOS downlink channel in the number of reset to 0. |
commonForwardPathFramingErrors | 1.3.6.1.4.1.17409.1.3.2.1.3.2 | counter | read-write |
Downlink Channel frames wrong number reset to 0. |
commonForwardPathCRCErrors | 1.3.6.1.4.1.17409.1.3.2.1.3.3 | counter | read-write |
CRC errors down the number of reset to 0. |
commonInvalidMacCmds | 1.3.6.1.4.1.17409.1.3.2.1.3.4 | counter | read-write |
Invalid MAC layer order wrong number reset to 0. |
commonBackwardPathCollisionTimes | 1.3.6.1.4.1.17409.1.3.2.1.3.5 | counter | read-write |
Uplink Packet collision frequency, reset to 0. |
commonRfGroup | 1.3.6.1.4.1.17409.1.3.2.2 | |||
commonReturnPathFrequency | 1.3.6.1.4.1.17409.1.3.2.2.1 | integer | read-only |
Channel uplink frequency units Hz. The value of this object should be stored in non-volatile memory. |
commonForwardPathFrequency | 1.3.6.1.4.1.17409.1.3.2.2.2 | integer | read-only |
Downlink frequency channel, flat Hz. The value of this object should be stored in non-volatile memory. |
commonProvisionedReturnPowerLevel | 1.3.6.1.4.1.17409.1.3.2.2.3 | integer | read-write |
Upstream channel power levels and units for dBuV. When the internal use of this value will be rounded to the nearest support value. Reading return to this subject when the actual value rather than rounding value. The value of this object should be stored in non-volatile memory. |
commonForwardPathReceiveLevel | 1.3.6.1.4.1.17409.1.3.2.2.4 | integer | read-only |
Downlink Channel receive power levels, units dBuV. |
commonMaxReturnPower | 1.3.6.1.4.1.17409.1.3.2.2.5 | integer | read-write |
The largest upstream channel power levels and units for dBuV. The value of this object should be stored in non-volatile memory. |
commonAdminUseEthernet | 1.3.6.1.4.1.17409.1.3.3 | |||
commonAgentGroup | 1.3.6.1.4.1.17409.1.3.3.1 | |||
commonAgentBootWay | 1.3.6.1.4.1.17409.1.3.3.1.1 | integer | read-write |
Starting Method Acting Enumeration: 'bootBOOTP': 2, 'bootDefault': 1, 'bootTFTP': 3. |
commonAgentReset | 1.3.6.1.4.1.17409.1.3.3.1.2 | integer | read-write |
Acting Restart, write'1 'will enable agents to restart, the value will be included in other non-functional. Reading this object return value'1 ', the agent had no effect on. Enumeration: 'reset': 1. |
commonAgentMaxTraps | 1.3.6.1.4.1.17409.1.3.3.1.3 | integer | read-write |
Acting detected alarm when sent to the management of the largest number of TRAP, 0 that manufacturers use the default default values. |
commonAgentTrapMinInterval | 1.3.6.1.4.1.17409.1.3.3.1.4 | integer | read-write |
Acting TRAP send the minimum spacing units for s. |
commonAgentTrapMaxInterval | 1.3.6.1.4.1.17409.1.3.3.1.5 | integer | read-write |
Acting TRAP send the largest spacing units for s. |
commonTrapAck | 1.3.6.1.4.1.17409.1.3.3.1.6 | octet string | read-write |
The variables used to notify Snmp agents, it issued the warning Trap has received information management console, do not have to re-hair. The content of the variables in alarmLogInformation MIB and the same warning. Agents received after the adoption of alarmLogInformation management can clearly know the host response is a warning which Trap information, thereby stop the alarm information re the Trap. |
commonAgentTrapTable | 1.3.6.1.4.1.17409.1.3.3.1.7 | no-access |
Acting Information Table TRAP. |
|
1.3.6.1.4.1.17409.1.3.3.1.7.1 | no-access |
Acting Head TRAP Information Table. |
||
commonAgentTrapIndex | 1.3.6.1.4.1.17409.1.3.3.1.7.1.1 | integer | read-only |
TRAP Table Index. |
commonAgentTrapIP | 1.3.6.1.4.1.17409.1.3.3.1.7.1.2 | ipaddress | read-write |
When the purpose of the TRAP host's IP address. |
commonAgentTrapCommunity | 1.3.6.1.4.1.17409.1.3.3.1.7.1.3 | displaystring | read-write |
Send the Community string TRAP. |
commonAgentTrapStatus | 1.3.6.1.4.1.17409.1.3.3.1.7.1.4 | integer | read-write |
It said the opening of the TRAP. Enumeration: 'commonAgentTrapEnable': 1, 'commonAgentTrapDisable': 2. |
commonDeviceGroup | 1.3.6.1.4.1.17409.1.3.3.2 | |||
commonDeviceNum | 1.3.6.1.4.1.17409.1.3.3.2.1 | integer | read-write |
The agent said that the current management is the number of devices. |
commonDeviceInfoTable | 1.3.6.1.4.1.17409.1.3.3.2.2 | no-access |
Acting is currently public information management equipment List. |
|
1.3.6.1.4.1.17409.1.3.3.2.2.1 | no-access |
Acting is currently public information management equipment list Table Head. |
||
commonDeviceSlot | 1.3.6.1.4.1.17409.1.3.3.2.2.1.1 | integer | read-only |
Acting is currently under the management of the equipment list of public information table Index. |
commonDevicesID | 1.3.6.1.4.1.17409.1.3.3.2.2.1.2 | octet string | read-only |
Designated equipment manufacturers logo. |
commonDeviceVendor | 1.3.6.1.4.1.17409.1.3.3.2.2.1.3 | displaystring | read-only |
Equipment manufacturers. |
commonDeviceModelNumber | 1.3.6.1.4.1.17409.1.3.3.2.2.1.4 | displaystring | read-only |
Equipment Model. |
commonDeviceSerialNumber | 1.3.6.1.4.1.17409.1.3.3.2.2.1.5 | displaystring | read-only |
The string of equipment. |
commonDeviceVendorInfo | 1.3.6.1.4.1.17409.1.3.3.2.2.1.6 | displaystring | read-only |
Equipment suppliers of other special designated information. |
commonDeviceStatus | 1.3.6.1.4.1.17409.1.3.3.2.2.1.7 | octet string | read-only |
The state equipment Bit 0: RSVD0 Bit 1: RSVD1 Bit 2: RSVD2 Bit 3: MAJOR ALARMS Bit 4: MINOR ALARMS Bit 5: RSVD5 Bit 6: RSVD6 Bit 7: RSVD7 |
commonDeviceReset | 1.3.6.1.4.1.17409.1.3.3.2.2.1.8 | integer | read-write |
Write'1 'will be reset equipment, other values will be written into the non-functional. Reading this object return value'1 ', had no effect on equipment. Enumeration: 'reset': 1. |
commonDeviceAlarmDetectionControl | 1.3.6.1.4.1.17409.1.3.3.2.2.1.9 | integer | read-write |
This object used to control equipment Alarm Detection. Enumeration: 'detectionDisabled': 1, 'detectionEnabled': 2, 'detectionEnabledAndRegenerate': 3. |
commonDeviceMACAddress | 1.3.6.1.4.1.17409.1.3.3.2.2.1.10 | ipaddress | read-only |
Equipment MAC address. |
commonDeviceTamperStatus | 1.3.6.1.4.1.17409.1.3.3.2.2.1.11 | integer | read-only |
Report of the safety switch equipment (such as whether to open up the lid) state that this object is called discrete attributes of a corresponding entry in the table. Intact that normal, expressed alarm compromised. Enumeration: 'intact': 1, 'compromised': 2. |
commonDeviceInternalTemperature | 1.3.6.1.4.1.17409.1.3.3.2.2.1.12 | integer | read-only |
Equipment Room (machine) temperature, units degrees Celsius. This request object attribute in a corresponding entry in the table. |
commonDeviceResetCause | 1.3.6.1.4.1.17409.1.3.3.2.2.1.13 | integer | read-only |
Equipment that the reasons for the recent reduction. Enumeration: 'powerup': 2, 'watchdog': 4, 'craft': 5, 'other': 1, 'command': 3. |
commonDeviceCraftStatus | 1.3.6.1.4.1.17409.1.3.3.2.2.1.14 | integer | read-only |
This object interface that local equipment (such as RS232 or RS485 interface) state. Enumeration: 'connected': 2, 'disconnected': 1. |
commonDevicesOID | 1.3.6.1.4.1.17409.1.3.3.2.2.1.15 | object identifier | read-only |
Goals identifier string, point to a concrete realization of the equipment. |
commonDeviceAcct | 1.3.6.1.4.1.17409.1.3.3.2.2.1.16 | counter | read-only |
Equipment that the accumulated work time, units of s. |
commonDeviceName | 1.3.6.1.4.1.17409.1.3.3.2.2.1.17 | displaystring | read-only |
Equipment Name. |
commonDeviceMFD | 1.3.6.1.4.1.17409.1.3.3.2.2.1.18 | displaystring | read-only |
Date of production equipment. |
commonDeviceFW | 1.3.6.1.4.1.17409.1.3.3.2.2.1.19 | displaystring | read-only |
Firmware information equipment. |
oaIdent | 1.3.6.1.4.1.17409.1.11 | |||
oaVendorOID | 1.3.6.1.4.1.17409.1.11.1 | object identifier | read-only |
This object provides manufacturers of optical amplifier MIB expansion. Without the expansion, this should be targeting at the optical amplifier nodes oaIdent. |
oaOutputOpticalPower | 1.3.6.1.4.1.17409.1.11.2 | integer | read-only |
The output optical power units to 0.1 dBm, the object attributes required to register an entry MIB. |
oaInputOpticalPower | 1.3.6.1.4.1.17409.1.11.3 | integer | read-only |
Input optical power units to 0.1 dBm, the object attributes required to register an entry MIB. |
oaPumpTable | 1.3.6.1.4.1.17409.1.11.4 | no-access |
EDFA laser pump Information Table. |
|
1.3.6.1.4.1.17409.1.11.4.1 | no-access |
Each laser-pumped optical amplifier Information Table Head. |
||
oaPumpIndex | 1.3.6.1.4.1.17409.1.11.4.1.1 | integer | read-only |
Laser-pumped optical amplifier index value. |
oaPumpBIAS | 1.3.6.1.4.1.17409.1.11.4.1.2 | integer | read-only |
The pump laser bias current, flat mA, this attribute MIB objects require an entry in the register. |
oaPumpTEC | 1.3.6.1.4.1.17409.1.11.4.1.3 | integer | read-only |
Current laser pump refrigeration unit is 0.01 A, this attribute MIB objects require an entry in the register. |
oaPumpTemp | 1.3.6.1.4.1.17409.1.11.4.1.4 | integer | read-only |
Laser pump temperature, units of 0.10 C, this attribute MIB objects require an entry in the register. |
oaNumberDCPowerSupply | 1.3.6.1.4.1.17409.1.11.5 | integer | read-only |
The number of internal DC power supply, 0 expressed transponder does not support this function. |
oaDCPowerSupplyMode | 1.3.6.1.4.1.17409.1.11.6 | integer | read-only |
Power supply mode: load sharing, standby switching or an independent power supply. Enumeration: 'loadsharing': 1, 'aloneSupply': 3, 'switchedRedundant': 2. |
oaDCPowerTable | 1.3.6.1.4.1.17409.1.11.7 | no-access |
DC Power Information Table. |
|
1.3.6.1.4.1.17409.1.11.7.1 | no-access |
DC Power Information Table Head. |
||
oaDCPowerIndex | 1.3.6.1.4.1.17409.1.11.7.1.1 | integer | read-only |
DC Power Index. |
oaDCPowerVoltage | 1.3.6.1.4.1.17409.1.11.7.1.2 | integer | read-only |
Supply voltage, the unit is 0.1 V. This attribute MIB objects require an entry in the register. |
oaDCPowerCurrent | 1.3.6.1.4.1.17409.1.11.7.1.3 | integer | read-only |
Electricity power supply unit is 0.01 A. This attribute MIB objects require an entry in the register. |
oaDCPowerName | 1.3.6.1.4.1.17409.1.11.7.1.4 | displaystring | read-only |
Indicate the name of the power supply, for example: 24 V DC power supply. This field value by the user, should at least be marked with a number of power supply voltage and distinguish between each other. When the object of this table have a warning, that this object should be put into the name of alarmText hfcAlarmEvent traps in the target. |
oaOutputOpticalPowerSet | 1.3.6.1.4.1.17409.1.11.11 | integer | read-write |
The output optical power control ,units to 0.1 dBm |
oaGainSet | 1.3.6.1.4.1.17409.1.11.12 | integer | read-write |
units to 0.1 dB |
powerSupplyStatusA | 1.3.6.1.4.1.17409.1.11.32 | integer | read-only |
Returns the operating status of power supply A. Enumeration: 'failure': 2, 'notInstalled': 3, 'nominal': 1, 'undefined': 0. |
powerSupplyStatusB | 1.3.6.1.4.1.17409.1.11.33 | integer | read-only |
Returns the operating status of power supply B. Enumeration: 'failure': 2, 'notInstalled': 3, 'nominal': 1, 'undefined': 0. |
hfcColdStart | 1.3.6.1.4.1.17409.10.0 |
HfcColdStart traps that are sent to re-initialization protocol entities, and entities agent configuration or agreement may have changed. This trap only after the success of transponder sent registration. |
||
hfcAlarmEvent | 1.3.6.1.4.1.17409.10.1 |
When detected in the event of alarm information sent this trap, whether bundled alarmText variable parameter under warning object to determine. Some of the parameters only need to bind the alarm first three variables. |
||
hfcWarmStart | 1.3.6.1.4.1.17409.10.2 |
HfcWarmStart traps that are sent to re-initialization protocol entities, and entities agent configuration or agreement has not changed. This trap only after the completion of transponder sent registration. |