NSCHippiSonet-MIB: View SNMP OID List / Download MIB

VENDOR: NSC


 Home MIB: NSCHippiSonet-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 nscHippiSonetEngineStatus 1.3.6.1.4.1.10.2.1.5.1 displaystring read-only
String describing the current state of the engine.
 nscHippiSonetRegisters 1.3.6.1.4.1.10.2.1.5.2
     nscHippiSonetUnframer 1.3.6.1.4.1.10.2.1.5.2.1
         nscHippiSonetUnframerStatus 1.3.6.1.4.1.10.2.1.5.2.1.1 displaystring read-only
Unframer status register.
         nscHippiSonetUnframerOHdma 1.3.6.1.4.1.10.2.1.5.2.1.2 displaystring read-only
Unframer overhead DMA register.
     nscHippiSonetFramer 1.3.6.1.4.1.10.2.1.5.2.2
         nscHippiSonetFramerStatus 1.3.6.1.4.1.10.2.1.5.2.2.1 displaystring read-only
Framer status register.
         nscHippiSonetFramerAdaptID 1.3.6.1.4.1.10.2.1.5.2.2.2 displaystring read-only
Adaptor ID (HDA) and enable status.
         nscHippiSonetFramerInput 1.3.6.1.4.1.10.2.1.5.2.2.3 displaystring read-only
Framer input register.
         nscHippiSonetFramerData 1.3.6.1.4.1.10.2.1.5.2.2.4 displaystring read-only
Framer data register.
         nscHippiSonetFramerIField 1.3.6.1.4.1.10.2.1.5.2.2.5 displaystring read-only
Framer I-Field register.
     nscHippiSonetMegaFifo 1.3.6.1.4.1.10.2.1.5.2.3
         nscHippiSonetMFcontrol 1.3.6.1.4.1.10.2.1.5.2.3.1 displaystring read-only
Mega FIFO control register.
         nscHippiSonetMFstatus 1.3.6.1.4.1.10.2.1.5.2.3.2 displaystring read-only
Mega FIFO status register.
         nscHippiSonetMFtimeout 1.3.6.1.4.1.10.2.1.5.2.3.3 displaystring read-only
Mega FIFO timeout register.
         nscHippiSonetMFConnectStatus 1.3.6.1.4.1.10.2.1.5.2.3.4 displaystring read-only
Mega FIFO connection status register.
 nscHippiSonetMonitor 1.3.6.1.4.1.10.2.1.5.3
     nscHippiSonetMonClock 1.3.6.1.4.1.10.2.1.5.3.1 integer read-only
500 Khz clock value (for time stamps).
     nscHippiSonetMonMFFlowControl 1.3.6.1.4.1.10.2.1.5.3.2 integer read-only
Mega FIFO flow control duration.
     nscHippiSonetMonDLFlowControl 1.3.6.1.4.1.10.2.1.5.3.3 integer read-only
Down line flow control duration
     nscHippiSonetMonBIPErrors 1.3.6.1.4.1.10.2.1.5.3.4 integer read-only
Received path BIP Errors.
     nscHippiSonetMonSrcBusy 1.3.6.1.4.1.10.2.1.5.3.5 integer read-only
Duration in 500Khz that the source was busy.
     nscHippiSonetMonSrcSOC 1.3.6.1.4.1.10.2.1.5.3.6 integer read-only
Number of source start of connections
     nscHippiSonetMonSrcEOC 1.3.6.1.4.1.10.2.1.5.3.7 integer read-only
Number of source end of connections
     nscHippiSonetMonDstConnectDuration 1.3.6.1.4.1.10.2.1.5.3.8 integer read-only
Number 500Khz cycles destination has been connected
     nscHippiSonetMonSrcConnectDuration 1.3.6.1.4.1.10.2.1.5.3.9 integer read-only
Number 500Khz cycles source has been connected
     nscHippiSonetMonDstConnectReject 1.3.6.1.4.1.10.2.1.5.3.10 integer read-only
Number of Destination connect rejects.
     nscHippiSonetMonSrcConnectFail 1.3.6.1.4.1.10.2.1.5.3.11 integer read-only
Number of source connect failures.
     nscHippiSonetMonLOF 1.3.6.1.4.1.10.2.1.5.3.12 integer read-only
Number of receive sonet Loss of Frame events
     nscHippiSonetMonLOS 1.3.6.1.4.1.10.2.1.5.3.13 integer read-only
Number of receive sonet Loss of Signal events
     nscHippiSonetMonDstBursts 1.3.6.1.4.1.10.2.1.5.3.14 integer read-only
Number of Destination bursts
     nscHippiSonetMonDstPackets 1.3.6.1.4.1.10.2.1.5.3.15 integer read-only
Number of Destination packets
     nscHippiSonetMonDstSync 1.3.6.1.4.1.10.2.1.5.3.16 integer read-only
Number of Destination sync errors
     nscHippiSonetMonDstLLRC 1.3.6.1.4.1.10.2.1.5.3.17 integer read-only
Number of Destination LLRC errors
     nscHippiSonetMonDstPE 1.3.6.1.4.1.10.2.1.5.3.18 integer read-only
Number of Destination Parity Errors
     nscHippiSonetMonDstConnect 1.3.6.1.4.1.10.2.1.5.3.19 integer read-only
Number of Destination connects
     nscHippiSonetMonSrcConnect 1.3.6.1.4.1.10.2.1.5.3.20 integer read-only
Number of source connects
     nscHippiSonetMonSrcPackets 1.3.6.1.4.1.10.2.1.5.3.21 integer read-only
Number of source packets
     nscHippiSonetMonSrcBursts 1.3.6.1.4.1.10.2.1.5.3.22 integer read-only
Number of source bursts
     nscHippiSonetMonSrcForceErrors 1.3.6.1.4.1.10.2.1.5.3.23 integer read-only
Number of Source Bad-data Force Errors
     nscHippiSonetMonSrcCRC 1.3.6.1.4.1.10.2.1.5.3.24 integer read-only
Number of Source CRC errors
     nscHippiSonetMonDstWords 1.3.6.1.4.1.10.2.1.5.3.25 integer read-only
Number of Destination burst words / 32 (Kbits)
     nscHippiSonetMonSrcWords 1.3.6.1.4.1.10.2.1.5.3.26 integer read-only
Number of Destination burst words / 32 (Kbits)
 nscHippiSonetAtoD 1.3.6.1.4.1.10.2.1.5.4
     nscHippiSonetADRecvOpticalPower 1.3.6.1.4.1.10.2.1.5.4.1 integer read-only
Receive optical power in dbm's
     nscHippiSonetADLaserBias 1.3.6.1.4.1.10.2.1.5.4.2 integer read-only
Laser bias voltage (in milli-volts)
     nscHippiSonetADLaserBackface 1.3.6.1.4.1.10.2.1.5.4.3 integer read-only
Laser backface voltage (in milli-volts)
     nscHippiSonetADInternalTemp 1.3.6.1.4.1.10.2.1.5.4.4 integer read-only
Internal temperature (degrees F)
     nscHippiSonetADExhaustTemp 1.3.6.1.4.1.10.2.1.5.4.5 integer read-only
Exhaust temperature (degrees F)
 nscHippiSonetSourceIField 1.3.6.1.4.1.10.2.1.5.5 displaystring read-only
Hippi source I-Field register.
 nscHippiSonetProfile 1.3.6.1.4.1.10.2.1.5.6
     nscHippiSonetOpticalRcvOffset 1.3.6.1.4.1.10.2.1.5.6.1 displaystring read-only
String representation of the floating value for the offset of the optical receive light formula.
     nscHippiSonetOpticalRcvSlope 1.3.6.1.4.1.10.2.1.5.6.2 displaystring read-only
String representation of the floating value for the slope of the optical receive light formula.
     nscHippiSonetBiasCurrent 1.3.6.1.4.1.10.2.1.5.6.3 integer read-only
Integer representation of the floating value for the baseline current of the transmit laser in milliamps. This value is used by the machine to determine the life of the laser.
     nscHippiSonetBiasTemp 1.3.6.1.4.1.10.2.1.5.6.4 integer read-only
Temperature in celcius at which the profiled bias current was taken. This value is used with the bias current to determine the life of the laser.
     nscHippiSonetBackfaceVoltage 1.3.6.1.4.1.10.2.1.5.6.5 displaystring read-only
String representation of the floting value of the Voltage in millivolts that was measured at the backface of the laser when it was new. This value is used with the current backface voltage as an additional method of determining if the transmit laser has become defective.
     nscHippiSonetIField 1.3.6.1.4.1.10.2.1.5.6.6 integer read-write
The I-Field address that is used by the hippi interface.
     nscHippiSonetBootPort 1.3.6.1.4.1.10.2.1.5.6.7 integer read-write
Which rs232 port the boot information should be sent to. Ports 1 & 2 are the only valid ports with 1 being located on the back of the machine and 2 on the front.
     nscHippiSonetPortSpeed 1.3.6.1.4.1.10.2.1.5.6.8 integer read-write
The baud rate to set the rs232 ports to at boot time.
     nscHippiSonetThreshold 1.3.6.1.4.1.10.2.1.5.6.9 integer read-write
Threshold of the mega-fifo at which flow control will be activated. The value represents 8ths of the fifo with 7 representing the fifo must be full before flow control is activated and 0 indicating that flow control will happen as soon as the mega-fifo starts to fill. This value may need to be adjusted to deal with time delays over vary long sonet links in that you want flow control to propagate back to the transmitting sonet box before it puts enough information on the line to overflow this machine.
     nscHippiTimeout 1.3.6.1.4.1.10.2.1.5.6.10 integer read-write
Timeout value to use when trying to connect from our hippi source. This timer is started when the source raises connect. If the destination fails to respond before the timer goes off, the connect will be aborted. The timer is represented as the number of 500 KHz clock ticks.
     nscHippiSonetDipSwitch 1.3.6.1.4.1.10.2.1.5.6.11 integer read-write
This is a software switch that functions much like a hardware dip switch. At the moment, the only use of this switch is to define whether the unit will act as the master clock for the sonet line. The bit values are defined as follows: x x x x x x 1 - assert master clock x x x x x 1 x - not assigned x x x x 1 x x - not assigned x x x 1 x x x - not assigned x x 1 x x x x - not assigned x 1 x x x x x - not assigned 1 x x x x x x - not assigned