NMS510-MIB: View SNMP OID List / Download MIB

VENDOR: GENERAL DATACOMM


 Home MIB: NMS510-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 nms510 1.3.6.1.4.1.498.8.6
     nms510MIBversion 1.3.6.1.4.1.498.8.6.1 displaystring read-only
Identifies the version of the MIB. The format of the version is x.yzT, where 'x' identifies the major revision number, 'y' identifies the minor revision number, 'z' identifies the typographical revision, and T identifies the test revision. Acceptable values for the individual revision components are as follows: x: 1 - 9 y: 0 - 9 z: 0 - 9 T: A - Z Upon formal release, no designation for the test revision will be present.
     nms510UnitCfgTable 1.3.6.1.4.1.498.8.6.2 no-access
The NMS510 Unit Configuration table. This table augments the GDC SC5520 Unit Configuration table, providing unit level configuration for each NMS510 device installed. For each entry in the GDC SC Unit Configuration table that represents an NMS510, there is a corresponding entry here whereby the value of the gdcSCunitCfgIndex object is equivalent to the value of the nms510unitCfgIndex object.
         nms510UnitCfgEntry 1.3.6.1.4.1.498.8.6.2.1 no-access
The NMS510 Unit Configuration table entry. The information in this entry augments the information in the corresponding entry in the GDC SC Unit Configuration table and provides unit level configuration for the installed NMS510.
             nms510UnitCfgIndex 1.3.6.1.4.1.498.8.6.2.1.1 scinstance read-only
The index value which uniquely identifies the NMS510 to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, and drop of the NMS510 with no sub-identifier value.
             nms510DteCtsDelay 1.3.6.1.4.1.498.8.6.2.1.2 integer read-write
RTS/CTS Delay options ctsOn(1) Forces both RTS and CTS On regardless of the state of the attached business equipment (the transmitter is On regardless of the status of the RTS interface lead). MIB object nms510DteCtsDelayExt is ignored. cts0mSec(2) Provides zero bits of delay between active RTS and CTS being set to active. MIB object nms510DteCtsDelayExt must be set to ext0mSec(1). ctsFix3Char(3) Provides three character bits of delay between active RTS and CTS being set to active. MIB object nms510DteCtsDelayExt must be set to ext0mSec(1). Enumeration: 'ctsFixed3Char': 3, 'ctsOn': 1, 'cts0mSec': 2.
             nms510DteCtsDelayExt 1.3.6.1.4.1.498.8.6.2.1.3 integer read-write
RTS/CTS Delay options extension ext0mSec(1) Used to enable options cts0mSec(2) or ctsFix3Char(3) from MIB object nms510DteCtsDelay. ext30mSec(2) Provides 30 msec of delay between active RTS and CTS being set to active. MIB object nms510DteCtsDelay must be set for either cts0mSec(2) or ctsFix3Char(3). ext60mSec(3) Provides 60 msec of delay between active RTS and CTS being set to active. MIB object nms510DteCtsDelay must be set for either cts0mSec(2) or ctsFix3Char(3). ext90mSec(4) Provides 90 msec of delay between active RTS and CTS being set to active. MIB object nms510DteCtsDelay must be set for either cts0mSec(2) or ctsFix3Char(3). Enumeration: 'ext30mSec': 2, 'ext0mSec': 1, 'ext60mSec': 3, 'ext90mSec': 4.
             nms510FirmwareLevel 1.3.6.1.4.1.498.8.6.2.1.4 displaystring read-only
The version number of the firmware, to allow products to know which revision is installed. The released version number is sequenced from --, A-, ... AA, ... ZZ. Test versions are numerical from 01 to 99.
             nms510AlarmCfgCountWindow 1.3.6.1.4.1.498.8.6.2.1.5 integer read-write
The DDS Alarm Threshold Alarm Interval. It specifies the amount of time in minutes, 1 to 15 minutes, in which the threshold setting is to be exceeded for the alarm to occur. There is one Alarm Interval for all alarms that require thresholds: nms510FrameLossAlm.
             nms510SoftReset 1.3.6.1.4.1.498.8.6.2.1.6 integer read-write
This object will cause software reset in dataset. Enumeration: 'reset': 2, 'normal': 1.
             nms510FrontPanelInhibit 1.3.6.1.4.1.498.8.6.2.1.7 integer read-write
Inhibits front panel test switch. If a test switch is activated while inhibited it will simply be ignored. If enabled via the nms510FrontPanelEnable object the test switch will function as normal. Enumeration: 'fpEnabled': 2, 'execute': 3, 'fpInhibited': 1.
             nms510FrontPanelEnable 1.3.6.1.4.1.498.8.6.2.1.8 integer read-write
Enables front panel test switch. If a test switch is activated while inhibited, via the nms510FrontPanelInhibit object, it will simply be ignored. If enabled the test switch will function as normal. Enumeration: 'fpEnabled': 2, 'execute': 3, 'fpInhibited': 1.
             nms510HdlcInvert 1.3.6.1.4.1.498.8.6.2.1.9 integer read-write
Primary data invert option. Will enhance the quality of data when network does not provide B8Z5. Primarily used with DDS II 56k Enumeration: 'invert': 2, 'normal': 1.
             nms510PiggyBackDetect 1.3.6.1.4.1.498.8.6.2.1.10 integer read-only
If set to 2 then either a Data Rate Adadaptor or 530 card is installed. Enumeration: 'installed': 2, 'not-installed': 1.
             nms510ExtPortCtrlOut1 1.3.6.1.4.1.498.8.6.2.1.11 integer read-write
This option sets the external output state (on/off) of the current network element and displays the external output. Enumeration: 'on': 1, 'off': 2.
             nms510ExtPortCtrlOut2 1.3.6.1.4.1.498.8.6.2.1.12 integer read-write
This option sets the external output state (on/off) of the current network element and displays the external output. Enumeration: 'on': 1, 'off': 2.
     nms510AlarmData 1.3.6.1.4.1.498.8.6.4
         nms510NoResponseAlm 1.3.6.1.4.1.498.8.6.4.1
         nms510DiagRxErrAlm 1.3.6.1.4.1.498.8.6.4.2
         nms510PowerUpAlm 1.3.6.1.4.1.498.8.6.4.3
         nms510EEChkSumErrAlm 1.3.6.1.4.1.498.8.6.4.4
         nms510StcLoopbackAlm 1.3.6.1.4.1.498.8.6.4.5
         nms510NoSignalAlm 1.3.6.1.4.1.498.8.6.4.6
         nms510FpTestAlm 1.3.6.1.4.1.498.8.6.4.7
         nms510StreamingAlm 1.3.6.1.4.1.498.8.6.4.8
         nms510DSRLossAlm 1.3.6.1.4.1.498.8.6.4.9
         nms510DTRLossAlm 1.3.6.1.4.1.498.8.6.4.10
         nms510DTPLossAlm 1.3.6.1.4.1.498.8.6.4.11
         nms510DCDLossAlm 1.3.6.1.4.1.498.8.6.4.12
         nms510RXDLossAlm 1.3.6.1.4.1.498.8.6.4.13
         nms510TXDLossAlm 1.3.6.1.4.1.498.8.6.4.14
         nms510DBURequestForScanAlm 1.3.6.1.4.1.498.8.6.4.15
         nms510DBUOnalm 1.3.6.1.4.1.498.8.6.4.16
         nms510DBUFailedAlm 1.3.6.1.4.1.498.8.6.4.17
         nms510ExtInputChangeAlm 1.3.6.1.4.1.498.8.6.4.18
         nms510ExtInputLowAlm 1.3.6.1.4.1.498.8.6.4.19
         nms510FrameLossAlm 1.3.6.1.4.1.498.8.6.4.20
     nms510DiagCfgTable 1.3.6.1.4.1.498.8.6.6 no-access
The NMS510 Unit Diagonostic table.
         nms510DiagCfgEntry 1.3.6.1.4.1.498.8.6.6.1 no-access
The NMS510 Unit Diagonostic table entry.
             nms510DiagCfgIndex 1.3.6.1.4.1.498.8.6.6.1.1 scinstance read-only
The index value which uniquely identifies the NMS510 to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, and drop of the NMS510 with no sub-identifier value.
             nms510DiagSendCode 1.3.6.1.4.1.498.8.6.6.1.2 integer read-write
Configures the selftest pattern to be run during any diagonostic test involving selftest. If option SendOtherPattern is selected, then pattern will default to 15 bit if unit is set for 56k-DDS/sc-multi point else pattern will default to 511 bit for all other conditions Enumeration: 'send15BitPattern': 4, 'sendOtherPattern': 1, 'send2047Pattern': 3, 'send511Pattern': 2.
             nms510DiagTestExceptions 1.3.6.1.4.1.498.8.6.6.1.3 integer read-only
Indicates exceptions that have occurred that may affect interpretation of the test results. The value of this object is a sum. This sum initially take the value zero. Then, for each exception, the value associated with the exception is added to the sum. The exception values are: value exception 0 No errors 1 bit over range 2 block over range 4 bit and block over range Enumeration: 'blocksOutOfRange': 2, 'bitsOutOfRange': 3, 'blocksAndBitsOutOfRange': 4, 'noExceptions': 1.
             nms510DiagBitErrors 1.3.6.1.4.1.498.8.6.6.1.4 integer read-only
The bit errors of the last diagnostic test that involved a Selftest pattern. Reading bit errors while a diagnostic test in running will cause the unit to drop out of test and invalidate the bit errors. Bit errors should be read only after the test is completed. The valid range for bit errors is 0 to 1,023, 65535 will be returned if for any reason the test was terminated early.
             nms510DiagBlockErrors 1.3.6.1.4.1.498.8.6.6.1.5 integer read-only
The block errors of the last diagnostic test that involved a Selftest pattern. Reading block errors while a diagnostic test in running will cause the unit to drop out of test and invalidate the block errors. Block errors should be read only after the test is completed. The valid range for block errors is 0 to 1,023, 65535 will be returned if for any reason the test was terminated early.
             nms510DiagTestReset 1.3.6.1.4.1.498.8.6.6.1.6 integer read-write
This object will halt the execution of any and all diagnostic test that may be running with the exception of the Network Delay Test. This should only be used to terminate the test because reading this object will terminate the test. Enumeration: 'resetTest': 3, 'diagnostic': 2, 'normal': 1.
     nms510DiagExcTable 1.3.6.1.4.1.498.8.6.7 no-access
The NMS510 Unit Diagonostic table.
         nms510DiagExcEntry 1.3.6.1.4.1.498.8.6.7.1 no-access
The NMS510 Unit Diagonostic table entry.
             nms510DiagExcIndex 1.3.6.1.4.1.498.8.6.7.1.1 scinstance read-only
The index value which uniquely identifies the NMS510 to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, and drop of the NMS510 with no sub-identifier value.
             nms510DiagIntLineloop 1.3.6.1.4.1.498.8.6.7.1.2 integer read-write
Lineloop (or Analoop) can be either a Bilaterial or Unilaterial loopback depending on option ddsDteTermaloop. To initiate a Lineloop with Selftest SET this object and specifiy a blocksize. The blocksize indicates the number of blocks the Selftest pattern generator will run. There are 1000 bits/block. Emuns 3 through 10 are write only. The only valid responses to a READ are lineloopOn(2) or lineloopOff(1). This test will terminate after the specified number of blocks have been run. Reading test results via the nms510DiagBitErrors or nms510DiagBlockErrors objects while the test is running will cause the test to terminate prematurely and render the results invalid. Test results should be only read after the test is completed. The current Test Status can be obtained by reading this object or the nms510DiagTestStatus object on the unit under test. This test can also be terminated by seting the nms510DiagTestReset object. Enumeration: 'lineloopOn': 2, 'blocks500': 6, 'lineloopOff': 1, 'blocks100': 5, 'blocks50000': 10, 'blocks10000': 9, 'blocks1': 3, 'blocks1000': 7, 'blocks5000': 8, 'blocks10': 4.
             nms510DiagIntDataloop 1.3.6.1.4.1.498.8.6.7.1.3 integer read-write
To initiate a Dataloop with Selftest SET this object and specifiy a blocksize. The nms510 (the remote) unit will go into Dataloop and the master (the sc5520) unit will go into Selftest. The blocksize indicates the number of blocks the Selftest pattern generator will run. There are 1000 bits/block. Emuns 3 through 10 are write only. The only valid responses to a READ are dataloopOn(2) or dataloopOff(1). This test will terminate after the specified number of blocks have been run. Reading test results via the nms510DiagBitErrors or nms510DiagBlockErrors objects while the test is running will cause the test to terminate prematurely and render the results invalid. Test results should be read only after the test is completed and are available from the master (sc5520) unit. The current Test Status can be obtained by reading the sc5520DiagTestStatus object on the master unit, reading test status on the remote unit may interfere with the diagonostic test pattern and cause errors. This test can also be terminated by seting the nms510DiagTestReset object. Enumeration: 'blocks500': 6, 'blocks100': 5, 'blocks50000': 10, 'blocks10000': 9, 'blocks1': 3, 'blocks1000': 7, 'dataloopOff': 1, 'blocks5000': 8, 'blocks10': 4, 'dataloopOn': 2.
             nms510DiagEndToEndSelftest 1.3.6.1.4.1.498.8.6.7.1.4 integer read-write
To initiate an End to End Selftest(Error Rate Test) SET this object and specifiy a blocksize. Both the remote (nms510) amd master (sc5520) units will go into Selftest. The blocksize indicates the number of blocks the Selftest pattern generator will run. There are 1000 bits/block. Emuns 3 through 10 are write only. The only valid responses to a READ are selftestOn(2) or selftestOff(1). This test will terminate after the specified number of blocks have been run. Reading test results via the nms510DiagBitErrors or nms510DiagBlockErrors objects while the test is running will cause the test to terminate prematurely and render the results invalid. Test results should be read only after the test is completed and are available from both the remote (nms510) and master (sc5520) units. The current Test Status can be obtained by reading the sc5520DiagTestStatus object on the master unit, reading test status on the remote unit may interfere with the diagonostic test patternand cause errors. This test can also be terminated by seting the nms510DiagTestReset object. Enumeration: 'blocks500': 6, 'blocks100': 5, 'blocks50000': 10, 'blocks10000': 9, 'blocks1': 3, 'endToEndOff': 1, 'endToEndOn': 2, 'blocks1000': 7, 'blocks5000': 8, 'blocks10': 4.
             nms510DiagNetworkDelay 1.3.6.1.4.1.498.8.6.7.1.5 integer read-write
To initiate a Network Delay test SET this object and specifiy runDelayTest. Both the remote (nms510) and master (sc5520) units will go into a test to measure network delay. Emun 3 is write only. The only valid responses to a READ are delayTestOn(2) or delayTestOff(1). This test will terminate after 10 seconds. Test results should be read only after the test is completed and are available from the master (sc5520) unit. The current Test Status can be obtained by reading the sc5520DiagTestStatus object on the master unit, reading test status on the remote unit may interfere with the test and cause errors. This test can not be terminated early once it is started. Enumeration: 'runDelayTest': 3, 'delayTestOn': 2, 'delayTestOff': 1.
             nms510DiagTestStatus 1.3.6.1.4.1.498.8.6.7.1.6 integer read-only
This object gives the current diagonostic test status. noTest indicates that no diagonostic test is currently active. Reading this object while in a diagonostic test involing two units may interfere with a selftest pattern and invalidate the test results. Reading the sc5520DiagTestStatus (master unit) object during dagonostic tests involing two unit will not disrupt the test results. Enumeration: 'internalLineloop': 2, 'internalDataloop': 4, 'externalDataloop': 3, 'endToend': 6, 'serviceTestCenterLoop': 5, 'noTest': 1.
             nms510DiagExtDataloop 1.3.6.1.4.1.498.8.6.7.1.7 integer read-write
To initiate a Dataloop test with no Selftest SET this object and specifiy external, this will allow the data from the DTE attached to the far end unit (sc5520) to looped back to itself. Emun external(3) is write only. The only valid response to a READ is dataloopOn(2) or dataloopOff(1). To halt this test you must SET the nms510DiagTestReset object. Reading test results via the nms510DiagBitErrors or nms510DiagBlockErrors objects while the test is running will also cause the test to terminate. There are no test results associated with this test. Reading test status on the remote unit via nms510DiagTestStatus may interfere with the diagonostic test pattern generated from the terminal equiptment. Enumeration: 'dataloopOff': 1, 'external': 3, 'dataloopOn': 2.
     nms510AlarmCfgTable 1.3.6.1.4.1.498.8.6.8 no-access
The GDC NMS510 Alarm Configuration Table.
         nms510AlarmCfgEntry 1.3.6.1.4.1.498.8.6.8.1 no-access
An entry in the GDC NMS510 alarm Configuration table.
             nms510AlarmCfgIndex 1.3.6.1.4.1.498.8.6.8.1.1 scinstance read-only
This object is the index of the NMS510 Alarm Threshold Configuration table.
             nms510AlarmCfgIdentifier 1.3.6.1.4.1.498.8.6.8.1.2 object identifier read-only
The unique alarm identifier assigned to this alarm type. The format of this identifier is an OBJECT IDENTIFIER that has the following format: {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) gdc(498) xxx(x) alarm(z) yyy(y) where xxx(x) is the administratively assigned family object identifier (z) is the object identifier for alarms in the family defined MIB and yyy(y) is the administratively assigned alarm type identifier for this alarm.
             nms510AlarmCfgThreshold 1.3.6.1.4.1.498.8.6.8.1.3 integer read-write
This function sets/reads the alarm threashold settings criteria. This threshold is used along with the alarm window to determine the number of instances in a given time frame for a Frame Loss alarm to occur before the alarm is considered active. Frame Loss alarm only reported in DDS-2 line type. Alarm Table Entry Threshold Range Defaults ------------------ -------------------- -------------- -------- Frame Loss nms510FrameLossAlm 1 to 99 Count 10