NETWORK-TECHNOLOGIES-GLOBAL-REG: View SNMP OID List / Download MIB
VENDOR: NETWORK TECHNOLOGIES INC
Home | MIB: NETWORK-TECHNOLOGIES-GLOBAL-REG | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
nti | 1.3.6.1.4.1.3699 | |||
products | 1.3.6.1.4.1.3699.1 | |||
hardware | 1.3.6.1.4.1.3699.1.1 | |||
enviromux_MINI | 1.3.6.1.4.1.3699.1.1.3 | |||
monitoring | 1.3.6.1.4.1.3699.1.1.3.1 | |||
temperatureSensor1 | 1.3.6.1.4.1.3699.1.1.3.1.1 | |||
temperatureSensor1CurrentValue | 1.3.6.1.4.1.3699.1.1.3.1.1.1 | decimalpointvalue | read-only |
Current value of the temperature sensor connected to port 1 in tenths of degrees . This port is the right RJ-45 sensor port. The value is expressed in the units indicated in temperatureSensor1Unit. This object is only applicable if a temperature sensor is connected to port 1. |
temperatureSensor1Alert | 1.3.6.1.4.1.3699.1.1.3.1.1.2 | integer | read-only |
Current alert status of the temperature sensor connected to port 1. This port is the right RJ-45 sensor port. A value of 0 indicates that the sensor has not crossed either of its specified thresholds, while a value of 1 indicates that it has. This object is only applicable if a temperature sensor is connected to port 1. Enumeration: 'on': 1, 'off': 0. |
temperatureSensor2 | 1.3.6.1.4.1.3699.1.1.3.1.2 | |||
temperatureSensor2CurrentValue | 1.3.6.1.4.1.3699.1.1.3.1.2.1 | decimalpointvalue | read-only |
Current value of the temperature sensor connected to port 2 in tenths of degrees . This port is the left RJ-45 sensor port. The value is expressed in the units indicated in temperatureSensor2Unit. This object is only applicable if a temperature sensor is connected to port 2. |
temperatureSensor2Alert | 1.3.6.1.4.1.3699.1.1.3.1.2.2 | integer | read-only |
Current alert status of the temperature sensor connected to port 2. This port is the left RJ-45 sensor port. A value of 0 indicates that the sensor has not crossed either of its specified thresholds, while a value of 1 indicates that it has. This object is only applicable if a temperature sensor is connected to port 2. Enumeration: 'on': 1, 'off': 0. |
humiditySensor1 | 1.3.6.1.4.1.3699.1.1.3.1.3 | |||
humiditySensor1CurrentValue | 1.3.6.1.4.1.3699.1.1.3.1.3.1 | decimalpointvalue | read-only |
Current integer value in tenths of percents of the humidity sensor connected to port 1. This port is the right RJ-45 sensor port. The value corresponds directly with the value displayed on the summary page and the status page for this sensor. This object is only applicable if a humidity sensor is connected to port 1. |
humiditySensor1Alert | 1.3.6.1.4.1.3699.1.1.3.1.3.2 | integer | read-only |
Current alert status of the humidity sensor connected to port 1. This port is the right RJ-45 sensor port. A value of 0 indicates that the sensor has not crossed either of its specified thresholds, while a value of 1 indicates that it has. This object is only applicable if a humidity sensor is connected to port 1. Enumeration: 'on': 1, 'off': 0. |
humiditySensor2 | 1.3.6.1.4.1.3699.1.1.3.1.4 | |||
humiditySensor2CurrentValue | 1.3.6.1.4.1.3699.1.1.3.1.4.1 | decimalpointvalue | read-only |
Current integer value in tenths of percents of the humidity sensor connected to port 2. This port is the left RJ-45 sensor port. The value corresponds directly with the value displayed on the summary page and the status page for this sensor. This object is only applicable if a humidity sensor is connected to port 2. |
humiditySensor2Alert | 1.3.6.1.4.1.3699.1.1.3.1.4.2 | integer | read-only |
Current alert status of the humidity sensor connected to port 2. This port is the left RJ-45 sensor port. A value of 0 indicates that the sensor has not crossed either of its specified thresholds, while a value of 1 indicates that it has. his object is only applicable if a humidity sensor is connected to port 2. Enumeration: 'on': 1, 'off': 0. |
dryContact1 | 1.3.6.1.4.1.3699.1.1.3.1.5 | |||
dryContact1Status | 1.3.6.1.4.1.3699.1.1.3.1.5.1 | integer | read-only |
Current integer value of the dry contact sensor connected to port 1. A value of 0 represents OPEN, and a value of 1 represents CLOSED. The value corresponds directly with the value displayed on the summary page and the status page for this sensor. This object is only applicable if a dry contact sensor is connected to port 1. Enumeration: 'open': 0, 'closed': 1. |
dryContact1Alert | 1.3.6.1.4.1.3699.1.1.3.1.5.2 | integer | read-only |
Current alert status of the dry contact sensor connected to port 1. A value of 0 indicates that the sensor has not been set to its alert condition, while a value of 1 indicates that it has. This object is only applicable if a dry contact sensor is connected to port 1. Enumeration: 'on': 1, 'off': 0. |
dryContact2 | 1.3.6.1.4.1.3699.1.1.3.1.6 | |||
dryContact2Status | 1.3.6.1.4.1.3699.1.1.3.1.6.1 | integer | read-only |
Current integer value of the dry contact sensor connected to port 2. A value of 0 represents OPEN, and a value of 1 represents CLOSED. The value corresponds directly with the value displayed on the summary page and the status page for this sensor. This object is only applicable if a dry contact sensor is connected to port 2. Enumeration: 'open': 0, 'closed': 1. |
dryContact2Alert | 1.3.6.1.4.1.3699.1.1.3.1.6.2 | integer | read-only |
Current alert status of the dry contact sensor connected to port 2. value of 0 indicates that the sensor has not been set to its alert condition, while a value of 1 indicates that it has. This object is only applicable if a dry contact sensor is connected to port 2. Enumeration: 'on': 1, 'off': 0. |
dryContact3 | 1.3.6.1.4.1.3699.1.1.3.1.7 | |||
dryContact3Status | 1.3.6.1.4.1.3699.1.1.3.1.7.1 | integer | read-only |
Current integer value of the dry contact sensor connected to port 3. A value of 0 represents OPEN, and a value of 1 represents CLOSED. The value corresponds directly with the value displayed on the summary page and the status page for this sensor. This object is only applicable if a dry contact sensor is connected to port 3. Enumeration: 'open': 0, 'closed': 1. |
dryContact3Alert | 1.3.6.1.4.1.3699.1.1.3.1.7.2 | integer | read-only |
Current alert status of the dry contact sensor connected to port 3. A value of 0 indicates that the sensor has not been set to its alert condition, while a value of 1 indicates that it has. This object is only applicable if a dry contact sensor is connected to port 3. Enumeration: 'on': 1, 'off': 0. |
dryContact4 | 1.3.6.1.4.1.3699.1.1.3.1.8 | |||
dryContact4Status | 1.3.6.1.4.1.3699.1.1.3.1.8.1 | integer | read-only |
Current integer value of the dry contact sensor connected to port 4. A value of 0 represents OPEN, and a value of 1 represents CLOSED. The value corresponds directly with the value displayed on the summary page and the status page for this sensor. This object is only applicable if a dry contact sensor is connected to port 4. Enumeration: 'open': 0, 'closed': 1. |
dryContact4Alert | 1.3.6.1.4.1.3699.1.1.3.1.8.2 | integer | read-only |
Current alert status of the dry contact sensor connected to port 4. A value of 0 indicates that the sensor has not been set to its alert condition, while a value of 1 indicates that it has. This object is only applicable if a dry contact sensor is connected to port 4. Enumeration: 'on': 1, 'off': 0. |
waterSensor | 1.3.6.1.4.1.3699.1.1.3.1.9 | |||
waterStatus | 1.3.6.1.4.1.3699.1.1.3.1.9.1 | integer | read-only |
Current integer value of the water sensor. A value of 0 represents OPEN, and a value of 1 represents CLOSED. The value corresponds directly with the value displayed on the summary page and the status page for this sensor. This object is only applicable if a water sensor is connected. Enumeration: 'open': 0, 'closed': 1. |
waterAlert | 1.3.6.1.4.1.3699.1.1.3.1.9.2 | integer | read-only |
Current alert status of the water sensor. A value of 0 indicates that the sensor has not been set to its alert condition, while a value of 1 indicates that it has. This object is only applicable if a water sensor is connected. Enumeration: 'on': 1, 'off': 0. |
administration | 1.3.6.1.4.1.3699.1.1.3.2 | |||
hostSystem | 1.3.6.1.4.1.3699.1.1.3.2.1 | |||
sysName | 1.3.6.1.4.1.3699.1.1.3.2.1.1 | displaystring | read-only |
System node name. This value corresponds directly with the Node Name field on the General configuration page under the ADMINISTRATION menu. |
sysLocation | 1.3.6.1.4.1.3699.1.1.3.2.1.2 | displaystring | read-only |
System node location. his value corresponds directly with the Node Location field on the General configuration page under the ADMINISTRATION menu. |
sysIP | 1.3.6.1.4.1.3699.1.1.3.2.1.3 | displaystring | read-only |
System IP address. This value corresponds directly with the IP address assigned to the enviromux-MINI on the Network configuration page under the ADMINISTRATION menu. |
sysMask | 1.3.6.1.4.1.3699.1.1.3.2.1.4 | displaystring | read-only |
System Subnet Mask. This value corresponds directly with the Subnet Mask assigned to the enviromux-MINI on the Network configuration page under the ADMINISTRATION menu. |
sysGateway | 1.3.6.1.4.1.3699.1.1.3.2.1.5 | displaystring | read-only |
System Default Gateway. This value corresponds directly with the Default Gateway assigned to the enviromux-MINI on the Network configuration page under the ADMINISTRATION menu. |
sysDNS | 1.3.6.1.4.1.3699.1.1.3.2.1.6 | displaystring | read-only |
System DNS server. This value corresponds directly with the DNS server assigned to the enviromux-MINI on the Network configuration page under the ADMINISTRATION menu. |
temperatureSensor1Adm | 1.3.6.1.4.1.3699.1.1.3.2.2 | |||
temperatureSensor1Name | 1.3.6.1.4.1.3699.1.1.3.2.2.1 | displaystring | read-write |
Current name assigned to the temperature sensor connected to port 1. This port is the right RJ-45 sensor port. This value corresponds directly with the name entered in the configuration page for this sensor. This object is only applicable if a temperature sensor is connected to port 1. |
temperatureSensor1Unit | 1.3.6.1.4.1.3699.1.1.3.2.2.2 | displaystring | read-write |
Temperature units for the value of the temperature sensor connected to port 1. This port is the right RJ-45 sensor port. The unit may either be Fahrenheit or Celsius, and corresponds directly with the unit chosen on the configuration page for this sensor. This object is only applicable if a temperature sensor is connected to port 1 or 2. |
temperatureSensor1LowThreshold | 1.3.6.1.4.1.3699.1.1.3.2.2.3 | displaystring | read-write |
Low threshold assigned to the temperature sensor connected to port 1. This port is the right RJ-45 sensor port. This value corresponds directly with the low threshold value entered in the configuration page for this sensor. This object is only applicable if a temperature sensor is connected to port 1. |
temperatureSensor1HighThreshold | 1.3.6.1.4.1.3699.1.1.3.2.2.4 | displaystring | read-write |
High threshold assigned to the temperature sensor connected to port 1. This port is the right RJ-45 sensor port. This value corresponds directly with the high threshold value entered in the configuration page for this sensor. This object is only applicable if a temperature sensor is connected to port 1. |
temperatureSensor2Adm | 1.3.6.1.4.1.3699.1.1.3.2.3 | |||
temperatureSensor2Name | 1.3.6.1.4.1.3699.1.1.3.2.3.1 | displaystring | read-write |
Current name assigned to the temperature sensor connected to port 2. This port is the left RJ-45 sensor port. This value corresponds directly with the name entered in the configuration page for this sensor. This object is only applicable if a temperature sensor is connected to port 2. |
temperatureSensor2Unit | 1.3.6.1.4.1.3699.1.1.3.2.3.2 | displaystring | read-write |
Temperature units for the value of the temperature sensor connected to port 2. This port is the left RJ-45 sensor port. The unit may either be Fahrenheit or Celsius, and corresponds directly with the unit chosen on the configuration page for this sensor. This object is only applicable if a temperature sensor is connected to port 1 or 2. |
temperatureSensor2LowThreshold | 1.3.6.1.4.1.3699.1.1.3.2.3.3 | displaystring | read-write |
Low threshold assigned to the temperature sensor connected to port 2. This port is the left RJ-45 sensor port. This value corresponds directly with the low threshold value entered in the configuration page for this sensor. This object is only applicable if a temperature sensor is connected to port 2. |
temperatureSensor2HighThreshold | 1.3.6.1.4.1.3699.1.1.3.2.3.4 | displaystring | read-write |
High threshold assigned to the temperature sensor connected to port 2. This port is the left RJ-45 sensor port. This value corresponds directly with the high threshold value entered in the configuration page for this sensor. This object is only applicable if a temperature sensor is connected to port 2. |
humiditySensor1Adm | 1.3.6.1.4.1.3699.1.1.3.2.4 | |||
humiditySensor1Name | 1.3.6.1.4.1.3699.1.1.3.2.4.1 | displaystring | read-write |
Current name assigned to the humidity sensor connected to port 1. This port is the right RJ-45 sensor port. This value corresponds directly with the name entered in the configuration page for this sensor. This object is only applicable if a humidity sensor is connected to port 1. |
humiditySensor1LowThreshold | 1.3.6.1.4.1.3699.1.1.3.2.4.2 | displaystring | read-write |
Low threshold assigned to the humidity sensor connected to port 1. This port is the right RJ-45 sensor port. This value corresponds directly with the low threshold value entered in the configuration page for this sensor. This object is only applicable if a humidity sensor is connected to port 1. |
humiditySensor1HighThreshold | 1.3.6.1.4.1.3699.1.1.3.2.4.3 | displaystring | read-write |
High threshold assigned to the humidity sensor connected to port 1. This port is the right RJ-45 sensor port. This value corresponds directly with the high threshold value entered in the configuration page for this sensor. This object is only applicable if a humidity sensor is connected to port 1. |
humiditySensor2Adm | 1.3.6.1.4.1.3699.1.1.3.2.5 | |||
humiditySensor2Name | 1.3.6.1.4.1.3699.1.1.3.2.5.1 | displaystring | read-write |
Current name assigned to the humidity sensor connected to port 2. This port is the left RJ-45 sensor port. This value corresponds directly with the name entered in the configuration page for this sensor. This object is only applicable if a humidity sensor is connected to port 2. |
humiditySensor2LowThreshold | 1.3.6.1.4.1.3699.1.1.3.2.5.2 | displaystring | read-write |
Low threshold assigned to the humidity sensor connected to port 2. This port is the left RJ-45 sensor port. This value corresponds directly with the low threshold value entered in the configuration page for this sensor. This object is only applicable if a humidity sensor is connected to port 2. |
humiditySensor2HighThreshold | 1.3.6.1.4.1.3699.1.1.3.2.5.3 | displaystring | read-write |
High threshold assigned to the humidity sensor connected to port 1. This port is the right RJ-45 sensor port. This value corresponds directly with the high threshold value entered in the configuration page for this sensor. This object is only applicable if a humidity sensor is connected to port 1. |
dryContact1Adm | 1.3.6.1.4.1.3699.1.1.3.2.6 | |||
dryContact1Name | 1.3.6.1.4.1.3699.1.1.3.2.6.1 | displaystring | read-write |
Current name assigned to the dry contact sensor connected to port 1. This value corresponds directly with the name entered in the configuration page for this sensor. This object is only applicable if a dry contact sensor is connected to port 1. |
dryContact1AlertStatus | 1.3.6.1.4.1.3699.1.1.3.2.6.2 | integer | read-write |
Status which generates an alert condition for the dry contact sensor connected to port 1. A value of 0 represents OPEN, and a value of 1 represents CLOSED. This value corresponds directly with the Alert When value entered in the configuration page for this sensor. This object is only applicable if a dry contact sensor is connected to port 1. Enumeration: 'alert-when-closed': 1, 'alert-when-open': 0. |
dryContact2Adm | 1.3.6.1.4.1.3699.1.1.3.2.7 | |||
dryContact2Name | 1.3.6.1.4.1.3699.1.1.3.2.7.1 | displaystring | read-write |
Current name assigned to the dry contact sensor connected to port 2. This value corresponds directly with the name entered in the configuration page for this sensor. This object is only applicable if a dry contact sensor is connected to port 2. |
dryContact2AlertStatus | 1.3.6.1.4.1.3699.1.1.3.2.7.2 | integer | read-write |
Status which generates an alert condition for the dry contact sensor connected to port 2. A value of 0 represents OPEN, and a value of 1 represents CLOSED. This value corresponds directly with the Alert When value entered in the configuration page for this sensor. This object is only applicable if a dry contact sensor is connected to port 2. Enumeration: 'alert-when-closed': 1, 'alert-when-open': 0. |
dryContact3Adm | 1.3.6.1.4.1.3699.1.1.3.2.8 | |||
dryContact3Name | 1.3.6.1.4.1.3699.1.1.3.2.8.1 | displaystring | read-write |
Current name assigned to the dry contact sensor connected to port 3. This value corresponds directly with the name entered in the configuration page for this sensor. This object is only applicable if a dry contact sensor is connected to port 3. |
dryContact3AlertStatus | 1.3.6.1.4.1.3699.1.1.3.2.8.2 | integer | read-write |
Status which generates an alert condition for the dry contact sensor connected to port 3. A value of 0 represents OPEN, and a value of 1 represents CLOSED. This value corresponds directly with the Alert When value entered in the configuration page for this sensor. This object is only applicable if a dry contact sensor is connected to port 3. Enumeration: 'alert-when-closed': 1, 'alert-when-open': 0. |
dryContact4Adm | 1.3.6.1.4.1.3699.1.1.3.2.9 | |||
dryContact4Name | 1.3.6.1.4.1.3699.1.1.3.2.9.1 | displaystring | read-write |
Current name assigned to the dry contact sensor connected to port 4. This value corresponds directly with the name entered in the configuration page for this sensor. This object is only applicable if a dry contact sensor is connected to port 4. |
dryContact4AlertStatus | 1.3.6.1.4.1.3699.1.1.3.2.9.2 | integer | read-write |
Status which generates an alert condition for the dry contact sensor connected to port 4. A value of 0 represents OPEN, and a value of 1 represents CLOSED. This value corresponds directly with the Alert When value entered in the configuration page for this sensor. This object is only applicable if a dry contact sensor is connected to port 4. Enumeration: 'alert-when-closed': 1, 'alert-when-open': 0. |
waterSensorAdm | 1.3.6.1.4.1.3699.1.1.3.2.10 | |||
waterName | 1.3.6.1.4.1.3699.1.1.3.2.10.1 | displaystring | read-write |
Current name assigned to the water sensor. This value corresponds directly with the name entered in the configuration page for this sensor. This object is only applicable if a water sensor is connected. |
waterAlertStatus | 1.3.6.1.4.1.3699.1.1.3.2.10.2 | integer | read-write |
Status which generates an alert condition for the water sensor. A value of 0 represents OPEN, and a value of 1 represents CLOSED. This value corresponds directly with the Alert When value entered in the configuration page for this sensor. This object is only applicable if a water sensor is connected. Enumeration: 'alert-when-closed': 1, 'alert-when-open': 0. |
version | 1.3.6.1.4.1.3699.1.1.3.3 | displaystring | read-only |
Code version |
envTraps | 1.3.6.1.4.1.3699.1.1.3.100 | |||
temperatureSensor1Trap | 1.3.6.1.4.1.3699.1.1.3.100.1 |
Trap for alert from temperature sensor connected to port 1. Received if this sensor is configured to send SNMP traps using the Configuration page, and SNMP is enabled on the Network configuration page under the ADMINISTRATION menu. |
||
temperatureSensor2Trap | 1.3.6.1.4.1.3699.1.1.3.100.2 |
Trap for alert from temperature sensor connected to port 2. Received if this sensor is configured to send SNMP traps using the Configuration page, and SNMP is enabled on the Network configuration page under the ADMINISTRATION menu. |
||
humiditySensor1Trap | 1.3.6.1.4.1.3699.1.1.3.100.3 |
Trap for alert from humidity sensor connected to port 1. Received if this sensor is configured to send SNMP traps using the Configuration page, and SNMP is enabled on the Network configuration page under the ADMINISTRATION menu. |
||
humiditySensor2Trap | 1.3.6.1.4.1.3699.1.1.3.100.4 |
Trap for alert from humidity sensor connected to port 2. Received if this sensor is configured to send SNMP traps using the Configuration page, and SNMP is enabled on the Network configuration page under the ADMINISTRATION menu. |
||
dryContactSensor1Trap | 1.3.6.1.4.1.3699.1.1.3.100.5 |
Trap for alert from dry contact sensor connected to port 1. Received if this sensor is configured to send SNMP traps using the Configuration page, and SNMP is enabled on the Network configuration page under the ADMINISTRATION menu. |
||
dryContactSensor2Trap | 1.3.6.1.4.1.3699.1.1.3.100.6 |
Trap for alert from dry contact sensor connected to port 2. Received if this sensor is configured to send SNMP traps using the Configuration page, and SNMP is enabled on the Network configuration page under the ADMINISTRATION menu. |
||
dryContactSensor3Trap | 1.3.6.1.4.1.3699.1.1.3.100.7 |
Trap for alert from dry contact sensor connected to port 3. Received if this sensor is configured to send SNMP traps using the Configuration page, and SNMP is enabled on the Network configuration page under the ADMINISTRATION menu. |
||
dryContactSensor4Trap | 1.3.6.1.4.1.3699.1.1.3.100.8 |
Trap for alert from dry contact sensor connected to port 4. Received if this sensor is configured to send SNMP traps using the Configuration page, and SNMP is enabled on the Network configuration page under the ADMINISTRATION menu. |
||
waterSensor1Trap | 1.3.6.1.4.1.3699.1.1.3.100.9 |
Trap for alert from water sensor. Received if this sensor is configured to send SNMP traps using the Configuration page, and SNMP is enabled on the Network configuration page under the ADMINISTRATION menu. |
||
logTrap | 1.3.6.1.4.1.3699.1.1.3.100.100 |
Trap generated when a log entry is created. Received if log entries are configured to be sent as SNMP traps using the Log Methods page, and SNMP is enabled on the Network configuration page under the ADMINISTRATION menu. |
||
overflowTrap | 1.3.6.1.4.1.3699.1.1.3.100.101 |
Trap generated when has reached 90% capacity. Received if log overflow alerts are enabled and are configured to be sent as SNMP traps using the Log Overflow page, and SNMP is enabled on the Network configuration page under the ADMINISTRATION menu. |
||
otherProduct | 1.3.6.1.4.1.3699.1.1.200 | |||
software | 1.3.6.1.4.1.3699.1.2 | |||
experimental | 1.3.6.1.4.1.3699.2 |