NETWORK-TECHNOLOGIES-GLOBAL-REG: View SNMP OID List / Download MIB

VENDOR: NETWORK TECHNOLOGIES INC


 Home MIB: NETWORK-TECHNOLOGIES-GLOBAL-REG
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 nti 1.3.6.1.4.1.3699
           products 1.3.6.1.4.1.3699.1
               hardware 1.3.6.1.4.1.3699.1.1
                   enviromux_MINI 1.3.6.1.4.1.3699.1.1.3
                       monitoring 1.3.6.1.4.1.3699.1.1.3.1
                           temperatureSensor1 1.3.6.1.4.1.3699.1.1.3.1.1
                               temperatureSensor1CurrentValue 1.3.6.1.4.1.3699.1.1.3.1.1.1 decimalpointvalue read-only
Current value of the temperature sensor connected to port 1 in tenths of degrees . This port is the right RJ-45 sensor port. The value is expressed in the units indicated in temperatureSensor1Unit. This object is only applicable if a temperature sensor is connected to port 1.
                               temperatureSensor1Alert 1.3.6.1.4.1.3699.1.1.3.1.1.2 integer read-only
Current alert status of the temperature sensor connected to port 1. This port is the right RJ-45 sensor port. A value of 0 indicates that the sensor has not crossed either of its specified thresholds, while a value of 1 indicates that it has. This object is only applicable if a temperature sensor is connected to port 1. Enumeration: 'on': 1, 'off': 0.
                           temperatureSensor2 1.3.6.1.4.1.3699.1.1.3.1.2
                               temperatureSensor2CurrentValue 1.3.6.1.4.1.3699.1.1.3.1.2.1 decimalpointvalue read-only
Current value of the temperature sensor connected to port 2 in tenths of degrees . This port is the left RJ-45 sensor port. The value is expressed in the units indicated in temperatureSensor2Unit. This object is only applicable if a temperature sensor is connected to port 2.
                               temperatureSensor2Alert 1.3.6.1.4.1.3699.1.1.3.1.2.2 integer read-only
Current alert status of the temperature sensor connected to port 2. This port is the left RJ-45 sensor port. A value of 0 indicates that the sensor has not crossed either of its specified thresholds, while a value of 1 indicates that it has. This object is only applicable if a temperature sensor is connected to port 2. Enumeration: 'on': 1, 'off': 0.
                           humiditySensor1 1.3.6.1.4.1.3699.1.1.3.1.3
                               humiditySensor1CurrentValue 1.3.6.1.4.1.3699.1.1.3.1.3.1 decimalpointvalue read-only
Current integer value in tenths of percents of the humidity sensor connected to port 1. This port is the right RJ-45 sensor port. The value corresponds directly with the value displayed on the summary page and the status page for this sensor. This object is only applicable if a humidity sensor is connected to port 1.
                               humiditySensor1Alert 1.3.6.1.4.1.3699.1.1.3.1.3.2 integer read-only
Current alert status of the humidity sensor connected to port 1. This port is the right RJ-45 sensor port. A value of 0 indicates that the sensor has not crossed either of its specified thresholds, while a value of 1 indicates that it has. This object is only applicable if a humidity sensor is connected to port 1. Enumeration: 'on': 1, 'off': 0.
                           humiditySensor2 1.3.6.1.4.1.3699.1.1.3.1.4
                               humiditySensor2CurrentValue 1.3.6.1.4.1.3699.1.1.3.1.4.1 decimalpointvalue read-only
Current integer value in tenths of percents of the humidity sensor connected to port 2. This port is the left RJ-45 sensor port. The value corresponds directly with the value displayed on the summary page and the status page for this sensor. This object is only applicable if a humidity sensor is connected to port 2.
                               humiditySensor2Alert 1.3.6.1.4.1.3699.1.1.3.1.4.2 integer read-only
Current alert status of the humidity sensor connected to port 2. This port is the left RJ-45 sensor port. A value of 0 indicates that the sensor has not crossed either of its specified thresholds, while a value of 1 indicates that it has. his object is only applicable if a humidity sensor is connected to port 2. Enumeration: 'on': 1, 'off': 0.
                           dryContact1 1.3.6.1.4.1.3699.1.1.3.1.5
                               dryContact1Status 1.3.6.1.4.1.3699.1.1.3.1.5.1 integer read-only
Current integer value of the dry contact sensor connected to port 1. A value of 0 represents OPEN, and a value of 1 represents CLOSED. The value corresponds directly with the value displayed on the summary page and the status page for this sensor. This object is only applicable if a dry contact sensor is connected to port 1. Enumeration: 'open': 0, 'closed': 1.
                               dryContact1Alert 1.3.6.1.4.1.3699.1.1.3.1.5.2 integer read-only
Current alert status of the dry contact sensor connected to port 1. A value of 0 indicates that the sensor has not been set to its alert condition, while a value of 1 indicates that it has. This object is only applicable if a dry contact sensor is connected to port 1. Enumeration: 'on': 1, 'off': 0.
                           dryContact2 1.3.6.1.4.1.3699.1.1.3.1.6
                               dryContact2Status 1.3.6.1.4.1.3699.1.1.3.1.6.1 integer read-only
Current integer value of the dry contact sensor connected to port 2. A value of 0 represents OPEN, and a value of 1 represents CLOSED. The value corresponds directly with the value displayed on the summary page and the status page for this sensor. This object is only applicable if a dry contact sensor is connected to port 2. Enumeration: 'open': 0, 'closed': 1.
                               dryContact2Alert 1.3.6.1.4.1.3699.1.1.3.1.6.2 integer read-only
Current alert status of the dry contact sensor connected to port 2. value of 0 indicates that the sensor has not been set to its alert condition, while a value of 1 indicates that it has. This object is only applicable if a dry contact sensor is connected to port 2. Enumeration: 'on': 1, 'off': 0.
                           dryContact3 1.3.6.1.4.1.3699.1.1.3.1.7
                               dryContact3Status 1.3.6.1.4.1.3699.1.1.3.1.7.1 integer read-only
Current integer value of the dry contact sensor connected to port 3. A value of 0 represents OPEN, and a value of 1 represents CLOSED. The value corresponds directly with the value displayed on the summary page and the status page for this sensor. This object is only applicable if a dry contact sensor is connected to port 3. Enumeration: 'open': 0, 'closed': 1.
                               dryContact3Alert 1.3.6.1.4.1.3699.1.1.3.1.7.2 integer read-only
Current alert status of the dry contact sensor connected to port 3. A value of 0 indicates that the sensor has not been set to its alert condition, while a value of 1 indicates that it has. This object is only applicable if a dry contact sensor is connected to port 3. Enumeration: 'on': 1, 'off': 0.
                           dryContact4 1.3.6.1.4.1.3699.1.1.3.1.8
                               dryContact4Status 1.3.6.1.4.1.3699.1.1.3.1.8.1 integer read-only
Current integer value of the dry contact sensor connected to port 4. A value of 0 represents OPEN, and a value of 1 represents CLOSED. The value corresponds directly with the value displayed on the summary page and the status page for this sensor. This object is only applicable if a dry contact sensor is connected to port 4. Enumeration: 'open': 0, 'closed': 1.
                               dryContact4Alert 1.3.6.1.4.1.3699.1.1.3.1.8.2 integer read-only
Current alert status of the dry contact sensor connected to port 4. A value of 0 indicates that the sensor has not been set to its alert condition, while a value of 1 indicates that it has. This object is only applicable if a dry contact sensor is connected to port 4. Enumeration: 'on': 1, 'off': 0.
                           waterSensor 1.3.6.1.4.1.3699.1.1.3.1.9
                               waterStatus 1.3.6.1.4.1.3699.1.1.3.1.9.1 integer read-only
Current integer value of the water sensor. A value of 0 represents OPEN, and a value of 1 represents CLOSED. The value corresponds directly with the value displayed on the summary page and the status page for this sensor. This object is only applicable if a water sensor is connected. Enumeration: 'open': 0, 'closed': 1.
                               waterAlert 1.3.6.1.4.1.3699.1.1.3.1.9.2 integer read-only
Current alert status of the water sensor. A value of 0 indicates that the sensor has not been set to its alert condition, while a value of 1 indicates that it has. This object is only applicable if a water sensor is connected. Enumeration: 'on': 1, 'off': 0.
                       administration 1.3.6.1.4.1.3699.1.1.3.2
                           hostSystem 1.3.6.1.4.1.3699.1.1.3.2.1
                               sysName 1.3.6.1.4.1.3699.1.1.3.2.1.1 displaystring read-only
System node name. This value corresponds directly with the Node Name field on the General configuration page under the ADMINISTRATION menu.
                               sysLocation 1.3.6.1.4.1.3699.1.1.3.2.1.2 displaystring read-only
System node location. his value corresponds directly with the Node Location field on the General configuration page under the ADMINISTRATION menu.
                               sysIP 1.3.6.1.4.1.3699.1.1.3.2.1.3 displaystring read-only
System IP address. This value corresponds directly with the IP address assigned to the enviromux-MINI on the Network configuration page under the ADMINISTRATION menu.
                               sysMask 1.3.6.1.4.1.3699.1.1.3.2.1.4 displaystring read-only
System Subnet Mask. This value corresponds directly with the Subnet Mask assigned to the enviromux-MINI on the Network configuration page under the ADMINISTRATION menu.
                               sysGateway 1.3.6.1.4.1.3699.1.1.3.2.1.5 displaystring read-only
System Default Gateway. This value corresponds directly with the Default Gateway assigned to the enviromux-MINI on the Network configuration page under the ADMINISTRATION menu.
                               sysDNS 1.3.6.1.4.1.3699.1.1.3.2.1.6 displaystring read-only
System DNS server. This value corresponds directly with the DNS server assigned to the enviromux-MINI on the Network configuration page under the ADMINISTRATION menu.
                           temperatureSensor1Adm 1.3.6.1.4.1.3699.1.1.3.2.2
                               temperatureSensor1Name 1.3.6.1.4.1.3699.1.1.3.2.2.1 displaystring read-write
Current name assigned to the temperature sensor connected to port 1. This port is the right RJ-45 sensor port. This value corresponds directly with the name entered in the configuration page for this sensor. This object is only applicable if a temperature sensor is connected to port 1.
                               temperatureSensor1Unit 1.3.6.1.4.1.3699.1.1.3.2.2.2 displaystring read-write
Temperature units for the value of the temperature sensor connected to port 1. This port is the right RJ-45 sensor port. The unit may either be Fahrenheit or Celsius, and corresponds directly with the unit chosen on the configuration page for this sensor. This object is only applicable if a temperature sensor is connected to port 1 or 2.
                               temperatureSensor1LowThreshold 1.3.6.1.4.1.3699.1.1.3.2.2.3 displaystring read-write
Low threshold assigned to the temperature sensor connected to port 1. This port is the right RJ-45 sensor port. This value corresponds directly with the low threshold value entered in the configuration page for this sensor. This object is only applicable if a temperature sensor is connected to port 1.
                               temperatureSensor1HighThreshold 1.3.6.1.4.1.3699.1.1.3.2.2.4 displaystring read-write
High threshold assigned to the temperature sensor connected to port 1. This port is the right RJ-45 sensor port. This value corresponds directly with the high threshold value entered in the configuration page for this sensor. This object is only applicable if a temperature sensor is connected to port 1.
                           temperatureSensor2Adm 1.3.6.1.4.1.3699.1.1.3.2.3
                               temperatureSensor2Name 1.3.6.1.4.1.3699.1.1.3.2.3.1 displaystring read-write
Current name assigned to the temperature sensor connected to port 2. This port is the left RJ-45 sensor port. This value corresponds directly with the name entered in the configuration page for this sensor. This object is only applicable if a temperature sensor is connected to port 2.
                               temperatureSensor2Unit 1.3.6.1.4.1.3699.1.1.3.2.3.2 displaystring read-write
Temperature units for the value of the temperature sensor connected to port 2. This port is the left RJ-45 sensor port. The unit may either be Fahrenheit or Celsius, and corresponds directly with the unit chosen on the configuration page for this sensor. This object is only applicable if a temperature sensor is connected to port 1 or 2.
                               temperatureSensor2LowThreshold 1.3.6.1.4.1.3699.1.1.3.2.3.3 displaystring read-write
Low threshold assigned to the temperature sensor connected to port 2. This port is the left RJ-45 sensor port. This value corresponds directly with the low threshold value entered in the configuration page for this sensor. This object is only applicable if a temperature sensor is connected to port 2.
                               temperatureSensor2HighThreshold 1.3.6.1.4.1.3699.1.1.3.2.3.4 displaystring read-write
High threshold assigned to the temperature sensor connected to port 2. This port is the left RJ-45 sensor port. This value corresponds directly with the high threshold value entered in the configuration page for this sensor. This object is only applicable if a temperature sensor is connected to port 2.
                           humiditySensor1Adm 1.3.6.1.4.1.3699.1.1.3.2.4
                               humiditySensor1Name 1.3.6.1.4.1.3699.1.1.3.2.4.1 displaystring read-write
Current name assigned to the humidity sensor connected to port 1. This port is the right RJ-45 sensor port. This value corresponds directly with the name entered in the configuration page for this sensor. This object is only applicable if a humidity sensor is connected to port 1.
                               humiditySensor1LowThreshold 1.3.6.1.4.1.3699.1.1.3.2.4.2 displaystring read-write
Low threshold assigned to the humidity sensor connected to port 1. This port is the right RJ-45 sensor port. This value corresponds directly with the low threshold value entered in the configuration page for this sensor. This object is only applicable if a humidity sensor is connected to port 1.
                               humiditySensor1HighThreshold 1.3.6.1.4.1.3699.1.1.3.2.4.3 displaystring read-write
High threshold assigned to the humidity sensor connected to port 1. This port is the right RJ-45 sensor port. This value corresponds directly with the high threshold value entered in the configuration page for this sensor. This object is only applicable if a humidity sensor is connected to port 1.
                           humiditySensor2Adm 1.3.6.1.4.1.3699.1.1.3.2.5
                               humiditySensor2Name 1.3.6.1.4.1.3699.1.1.3.2.5.1 displaystring read-write
Current name assigned to the humidity sensor connected to port 2. This port is the left RJ-45 sensor port. This value corresponds directly with the name entered in the configuration page for this sensor. This object is only applicable if a humidity sensor is connected to port 2.
                               humiditySensor2LowThreshold 1.3.6.1.4.1.3699.1.1.3.2.5.2 displaystring read-write
Low threshold assigned to the humidity sensor connected to port 2. This port is the left RJ-45 sensor port. This value corresponds directly with the low threshold value entered in the configuration page for this sensor. This object is only applicable if a humidity sensor is connected to port 2.
                               humiditySensor2HighThreshold 1.3.6.1.4.1.3699.1.1.3.2.5.3 displaystring read-write
High threshold assigned to the humidity sensor connected to port 1. This port is the right RJ-45 sensor port. This value corresponds directly with the high threshold value entered in the configuration page for this sensor. This object is only applicable if a humidity sensor is connected to port 1.
                           dryContact1Adm 1.3.6.1.4.1.3699.1.1.3.2.6
                               dryContact1Name 1.3.6.1.4.1.3699.1.1.3.2.6.1 displaystring read-write
Current name assigned to the dry contact sensor connected to port 1. This value corresponds directly with the name entered in the configuration page for this sensor. This object is only applicable if a dry contact sensor is connected to port 1.
                               dryContact1AlertStatus 1.3.6.1.4.1.3699.1.1.3.2.6.2 integer read-write
Status which generates an alert condition for the dry contact sensor connected to port 1. A value of 0 represents OPEN, and a value of 1 represents CLOSED. This value corresponds directly with the Alert When value entered in the configuration page for this sensor. This object is only applicable if a dry contact sensor is connected to port 1. Enumeration: 'alert-when-closed': 1, 'alert-when-open': 0.
                           dryContact2Adm 1.3.6.1.4.1.3699.1.1.3.2.7
                               dryContact2Name 1.3.6.1.4.1.3699.1.1.3.2.7.1 displaystring read-write
Current name assigned to the dry contact sensor connected to port 2. This value corresponds directly with the name entered in the configuration page for this sensor. This object is only applicable if a dry contact sensor is connected to port 2.
                               dryContact2AlertStatus 1.3.6.1.4.1.3699.1.1.3.2.7.2 integer read-write
Status which generates an alert condition for the dry contact sensor connected to port 2. A value of 0 represents OPEN, and a value of 1 represents CLOSED. This value corresponds directly with the Alert When value entered in the configuration page for this sensor. This object is only applicable if a dry contact sensor is connected to port 2. Enumeration: 'alert-when-closed': 1, 'alert-when-open': 0.
                           dryContact3Adm 1.3.6.1.4.1.3699.1.1.3.2.8
                               dryContact3Name 1.3.6.1.4.1.3699.1.1.3.2.8.1 displaystring read-write
Current name assigned to the dry contact sensor connected to port 3. This value corresponds directly with the name entered in the configuration page for this sensor. This object is only applicable if a dry contact sensor is connected to port 3.
                               dryContact3AlertStatus 1.3.6.1.4.1.3699.1.1.3.2.8.2 integer read-write
Status which generates an alert condition for the dry contact sensor connected to port 3. A value of 0 represents OPEN, and a value of 1 represents CLOSED. This value corresponds directly with the Alert When value entered in the configuration page for this sensor. This object is only applicable if a dry contact sensor is connected to port 3. Enumeration: 'alert-when-closed': 1, 'alert-when-open': 0.
                           dryContact4Adm 1.3.6.1.4.1.3699.1.1.3.2.9
                               dryContact4Name 1.3.6.1.4.1.3699.1.1.3.2.9.1 displaystring read-write
Current name assigned to the dry contact sensor connected to port 4. This value corresponds directly with the name entered in the configuration page for this sensor. This object is only applicable if a dry contact sensor is connected to port 4.
                               dryContact4AlertStatus 1.3.6.1.4.1.3699.1.1.3.2.9.2 integer read-write
Status which generates an alert condition for the dry contact sensor connected to port 4. A value of 0 represents OPEN, and a value of 1 represents CLOSED. This value corresponds directly with the Alert When value entered in the configuration page for this sensor. This object is only applicable if a dry contact sensor is connected to port 4. Enumeration: 'alert-when-closed': 1, 'alert-when-open': 0.
                           waterSensorAdm 1.3.6.1.4.1.3699.1.1.3.2.10
                                 waterName 1.3.6.1.4.1.3699.1.1.3.2.10.1 displaystring read-write
Current name assigned to the water sensor. This value corresponds directly with the name entered in the configuration page for this sensor. This object is only applicable if a water sensor is connected.
                                 waterAlertStatus 1.3.6.1.4.1.3699.1.1.3.2.10.2 integer read-write
Status which generates an alert condition for the water sensor. A value of 0 represents OPEN, and a value of 1 represents CLOSED. This value corresponds directly with the Alert When value entered in the configuration page for this sensor. This object is only applicable if a water sensor is connected. Enumeration: 'alert-when-closed': 1, 'alert-when-open': 0.
                       version 1.3.6.1.4.1.3699.1.1.3.3 displaystring read-only
Code version
                       envTraps 1.3.6.1.4.1.3699.1.1.3.100
                               temperatureSensor1Trap 1.3.6.1.4.1.3699.1.1.3.100.1
Trap for alert from temperature sensor connected to port 1. Received if this sensor is configured to send SNMP traps using the Configuration page, and SNMP is enabled on the Network configuration page under the ADMINISTRATION menu.
                               temperatureSensor2Trap 1.3.6.1.4.1.3699.1.1.3.100.2
Trap for alert from temperature sensor connected to port 2. Received if this sensor is configured to send SNMP traps using the Configuration page, and SNMP is enabled on the Network configuration page under the ADMINISTRATION menu.
                               humiditySensor1Trap 1.3.6.1.4.1.3699.1.1.3.100.3
Trap for alert from humidity sensor connected to port 1. Received if this sensor is configured to send SNMP traps using the Configuration page, and SNMP is enabled on the Network configuration page under the ADMINISTRATION menu.
                               humiditySensor2Trap 1.3.6.1.4.1.3699.1.1.3.100.4
Trap for alert from humidity sensor connected to port 2. Received if this sensor is configured to send SNMP traps using the Configuration page, and SNMP is enabled on the Network configuration page under the ADMINISTRATION menu.
                               dryContactSensor1Trap 1.3.6.1.4.1.3699.1.1.3.100.5
Trap for alert from dry contact sensor connected to port 1. Received if this sensor is configured to send SNMP traps using the Configuration page, and SNMP is enabled on the Network configuration page under the ADMINISTRATION menu.
                               dryContactSensor2Trap 1.3.6.1.4.1.3699.1.1.3.100.6
Trap for alert from dry contact sensor connected to port 2. Received if this sensor is configured to send SNMP traps using the Configuration page, and SNMP is enabled on the Network configuration page under the ADMINISTRATION menu.
                               dryContactSensor3Trap 1.3.6.1.4.1.3699.1.1.3.100.7
Trap for alert from dry contact sensor connected to port 3. Received if this sensor is configured to send SNMP traps using the Configuration page, and SNMP is enabled on the Network configuration page under the ADMINISTRATION menu.
                               dryContactSensor4Trap 1.3.6.1.4.1.3699.1.1.3.100.8
Trap for alert from dry contact sensor connected to port 4. Received if this sensor is configured to send SNMP traps using the Configuration page, and SNMP is enabled on the Network configuration page under the ADMINISTRATION menu.
                               waterSensor1Trap 1.3.6.1.4.1.3699.1.1.3.100.9
Trap for alert from water sensor. Received if this sensor is configured to send SNMP traps using the Configuration page, and SNMP is enabled on the Network configuration page under the ADMINISTRATION menu.
                               logTrap 1.3.6.1.4.1.3699.1.1.3.100.100
Trap generated when a log entry is created. Received if log entries are configured to be sent as SNMP traps using the Log Methods page, and SNMP is enabled on the Network configuration page under the ADMINISTRATION menu.
                               overflowTrap 1.3.6.1.4.1.3699.1.1.3.100.101
Trap generated when has reached 90% capacity. Received if log overflow alerts are enabled and are configured to be sent as SNMP traps using the Log Overflow page, and SNMP is enabled on the Network configuration page under the ADMINISTRATION menu.
                   otherProduct 1.3.6.1.4.1.3699.1.1.200
               software 1.3.6.1.4.1.3699.1.2
           experimental 1.3.6.1.4.1.3699.2