Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
netscreenChassis | 1.3.6.1.4.1.3224.21 |
This module defines the objects that are used to monitor device status such as Battery, Fan, Power and Temperature |
||
nsPowerTable | 1.3.6.1.4.1.3224.21.1 | no-access |
Information describing installed power supply modules and their status |
|
1.3.6.1.4.1.3224.21.1.1 | no-access |
Information describing one power supply module and its status |
||
nsPowerId | 1.3.6.1.4.1.3224.21.1.1.1 | integer32 | read-only |
A 32-bit integer uniquely identifying the power supply id. For 5400, range is 1~3, For 5200, range is 1~2 |
nsPowerStatus | 1.3.6.1.4.1.3224.21.1.1.2 | integer32 | read-only |
A 32-bit integer uniquely identifying the power supply module's status: 0. Fail 1. Good 2. Not installed |
nsPowerDesc | 1.3.6.1.4.1.3224.21.1.1.3 | displaystring | read-only |
A description for the power supply module |
nsFanTable | 1.3.6.1.4.1.3224.21.2 | no-access |
Information describing the installed Fan modules and their status |
|
1.3.6.1.4.1.3224.21.2.1 | no-access |
Information describing one installed Fan module and its status |
||
nsFanId | 1.3.6.1.4.1.3224.21.2.1.1 | integer32 | read-only |
A 32-bit integer uniquely identifying the Fan id. At the time of this writing. |
nsFanStatus | 1.3.6.1.4.1.3224.21.2.1.2 | integer32 | read-only |
A 32-bit integer uniquely identifying the Fan module's status: 0. Fail 1. Good |
nsFanDesc | 1.3.6.1.4.1.3224.21.2.1.3 | displaystring | read-only |
A description for the Fan module |
sysBatteryStatus | 1.3.6.1.4.1.3224.21.3 | integer32 | read-only |
Information describing the installed Battery and its status: 1. Good 2. Error |
nsTemperatureTable | 1.3.6.1.4.1.3224.21.4 | no-access |
Information describing the temperature measured by each module |
|
1.3.6.1.4.1.3224.21.4.1 | no-access |
The temperature measured by a module |
||
nsTemperatureId | 1.3.6.1.4.1.3224.21.4.1.1 | integer32 | read-only |
A 32-bit integer uniquely identifying temperature measured on a board or on a component e.g. CPU |
nsTemperatureSlotId | 1.3.6.1.4.1.3224.21.4.1.2 | integer32 | read-only |
A 32-bit integer uniquely identifying the slot where the temperature is measured. |
nsTemperatureCur | 1.3.6.1.4.1.3224.21.4.1.3 | integer32 | read-only |
The current temperature measured by the module, unit is Celsius |
nsTemperatureDesc | 1.3.6.1.4.1.3224.21.4.1.4 | displaystring | read-only |
A description for the module |
nsSlotTable | 1.3.6.1.4.1.3224.21.5 | no-access |
Information describing the installed management and traffic processing modules and their status, built-in and internal module are also listed here. |
|
1.3.6.1.4.1.3224.21.5.1 | no-access |
Information describing one installed module and its status |
||
nsSlotId | 1.3.6.1.4.1.3224.21.5.1.1 | integer32 | read-only |
A 32-bit integer uniquely identifying the slot id. The range varies on different platforms |
nsSlotType | 1.3.6.1.4.1.3224.21.5.1.2 | displaystring | read-only |
A description of the installed module |
nsSlotStatus | 1.3.6.1.4.1.3224.21.5.1.3 | integer32 | read-only |
Slot status |
nsSlotSN | 1.3.6.1.4.1.3224.21.5.1.4 | displaystring | read-only |
Serial Number of the module |