NETI-PM-MIB: View SNMP OID List / Download MIB

VENDOR: NET INSIGHT AB


 Home MIB: NETI-PM-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 netiPMMIB 1.3.6.1.4.1.2928.6.2.17
The Net Insight PM (Performance Monitoring) MIB. The MIB implements objects for monitoring the performance of trunk interfaces, access interfaces and channels according to G.826.
       netiPMMIBObjects 1.3.6.1.4.1.2928.6.2.17.1
           pmTifGroup 1.3.6.1.4.1.2928.6.2.17.1.1
               pmTifTable 1.3.6.1.4.1.2928.6.2.17.1.1.1 no-access
Table of Performance Monitored trunk interfaces
                   pmTifEntry 1.3.6.1.4.1.2928.6.2.17.1.1.1.1 no-access
One entry for each trunk interface
                       pmTifIndex 1.3.6.1.4.1.2928.6.2.17.1.1.1.1.1 unsigned32 no-access
The index uniquely identifying this trunk interface.
                       pmTifAdminStatus 1.3.6.1.4.1.2928.6.2.17.1.1.1.1.2 integer read-write
The desired state of the PM function. Affects the operative state of the PM object Enumeration: 'down': 2, 'up': 1.
                       pmTifOperStatus 1.3.6.1.4.1.2928.6.2.17.1.1.1.1.3 integer read-only
PM operative state. Enumeration: 'down': 2, 'up': 1.
                       pmTifFailure 1.3.6.1.4.1.2928.6.2.17.1.1.1.1.4 displaystring read-only
Shows current failure state. An empty string indicates no failure
                       pmTifDataSource 1.3.6.1.4.1.2928.6.2.17.1.1.1.1.5 object identifier read-only
The PM Data Source object
                       pmTifDataSourceName 1.3.6.1.4.1.2928.6.2.17.1.1.1.1.6 displaystring read-only
The name of the PM Data Source
                       pmTifUatAlarmsEnabled 1.3.6.1.4.1.2928.6.2.17.1.1.1.1.7 truthvalue read-write
If set to `true(1)' then UAT alarms will be sent. Unavailable time (UAT) defines a state where a service is unable to perform its normal task due to severe errors for a longer period. It begins at detection of ten consecutive SES events and ends at detection of ten consecutive non-SES events. In both cases, the 10s are considered part of unavailable respective available time and effects the visibility of G.826 PM events (they are delayed 10s) Entry and exit of UAT is declared by raising and clearing an UAT alarm (if enabled)
                       pmTifTresholdAlarmsEnabled 1.3.6.1.4.1.2928.6.2.17.1.1.1.1.8 truthvalue read-write
If set to `true(1)' then threshold alarms will be sent. Each 15m and 24h current register counter can be assigned a threshold value. When crossed, a threshold crossing alarm will be sent for the interval if enabled. Raised alarm will be cleared at end of a following fault free interval i.e. one with all interval counter values below their threshold values and with no UAT. Only one TC alarm per interval can be raised, regardless of how many thresholds have been crossed.
                       pmTifPeriodicEventsEnabled 1.3.6.1.4.1.2928.6.2.17.1.1.1.1.9 truthvalue read-write
If set to `true(1)' then History Periodic Events will be sent.
                       pmTifZeroSuppressionEnabled 1.3.6.1.4.1.2928.6.2.17.1.1.1.1.10 truthvalue read-write
If set to `true(1)' then Zero Suppression mode is enabled Zero Suppression mode tells whether intervals with all current counters equal to zero shall be stored in the history log or not. If enabled, once a faulty interval is found, its current register content including a zero suppressed interval counter will be stored in the history log. The additional counter specifies how many fault free intervals have preceded the faulty one. In such way, history for a larger measurement period can be logged than would otherwise be possible
                       pmTifHistorySize 1.3.6.1.4.1.2928.6.2.17.1.1.1.1.11 integer read-write
The size of the history log Enumeration: 'small': 2, 'large': 3, 'none': 1.
                       pmTif15mTresholdES 1.3.6.1.4.1.2928.6.2.17.1.1.1.1.12 counter15m read-write
15 minute threshold value for ES. Current ES value equal to or above this threshold will raise a threshold alarm if enabled. A value of zero will disable threshold check.
                       pmTif15mTresholdSES 1.3.6.1.4.1.2928.6.2.17.1.1.1.1.13 counter15m read-write
15 minute threshold value for SES. Current SES value equal to or above this threshold will raise a threshold alarm if enabled. A value of zero will disable threshold check.
                       pmTif15mTresholdBBE 1.3.6.1.4.1.2928.6.2.17.1.1.1.1.14 gauge32 read-write
15 minute threshold value for BBE. Current BBE value equal to or above this threshold will raise a threshold alarm if enabled. A value of zero will disable threshold check.
                       pmTif15mTresholdSS 1.3.6.1.4.1.2928.6.2.17.1.1.1.1.15 counter15m read-write
15 minute threshold value for SS. Current SS value equal to or above this threshold will raise a threshold alarm if enabled. A value of zero will disable threshold check.
                       pmTif24hTresholdES 1.3.6.1.4.1.2928.6.2.17.1.1.1.1.16 counter24h read-write
24 hour threshold value for ES. Current ES value equal to or above this threshold will raise a threshold alarm if enabled. A value of zero will disable threshold check.
                       pmTif24hTresholdSES 1.3.6.1.4.1.2928.6.2.17.1.1.1.1.17 counter24h read-write
24 hour threshold value for SES. Current SES value equal to or above this threshold will raise a threshold alarm if enabled. A value of zero will disable threshold check.
                       pmTif24hTresholdBBE 1.3.6.1.4.1.2928.6.2.17.1.1.1.1.18 gauge32 read-write
24 hour threshold value for BBE. Current BBE value equal to or above this threshold will raise a threshold alarm if enabled. A value of zero will disable threshold check.
                       pmTif24hTresholdSS 1.3.6.1.4.1.2928.6.2.17.1.1.1.1.19 counter24h read-write
24 hour threshold value for SS. Current SS value equal to or above this threshold will raise a threshold alarm if enabled. A value of zero will disable threshold check.
               pmTifCurrentTable 1.3.6.1.4.1.2928.6.2.17.1.1.2 no-access
Table of PM data for the current 15 minute period
                   pmTifCurrentEntry 1.3.6.1.4.1.2928.6.2.17.1.1.2.1 no-access
One entry for each monitored object
                       pmTifCurrentTime 1.3.6.1.4.1.2928.6.2.17.1.1.2.1.2 counter15m read-only
Elapsed time in seconds for the current 15 minute period.
                       pmTifCurrentSuspect 1.3.6.1.4.1.2928.6.2.17.1.1.2.1.3 truthvalue read-only
Is Suspect flag, if set to `true(1)' the current 15 minute measurement period has unreliable measurement data.
                       pmTifCurrentZS 1.3.6.1.4.1.2928.6.2.17.1.1.2.1.4 counter32 read-only
Zero Suppression Counter. If the performance monitoring uses zero suppression, this counter specifies how many fault free intervals have preceded the faulty one.
                       pmTifCurrentESs 1.3.6.1.4.1.2928.6.2.17.1.1.2.1.5 counter15m read-only
Number of Errored Seconds (ES) for the current 15 minute period. ES is defined as one second of available time containing one or more Errored Blocks (EB) or at least one defect
                       pmTifCurrentSESs 1.3.6.1.4.1.2928.6.2.17.1.1.2.1.6 counter15m read-only
Number of Severe Errored Seconds (SES) for the current 15 minute period. SES is defined as one second of available time containing more than 30% Errored Blocks (EB) or at least one defect.
                       pmTifCurrentBBEs 1.3.6.1.4.1.2928.6.2.17.1.1.2.1.7 gauge32 read-only
Number of Background Block Error (BBE) for the current 15 minute period. BBE is defined as the number of Errored Blocks (EB) during one second of available time not part of SES
                       pmTifCurrentUASs 1.3.6.1.4.1.2928.6.2.17.1.1.2.1.8 counter15m read-only
Number of Unavailable Second (UAS) for the current 15 minute period. UAS is defined as one second of UAT (Unavailable Time). During UAT calculations of BBE, ES and SES are inhibited and no data collection of them is performed
                       pmTifCurrentSSs 1.3.6.1.4.1.2928.6.2.17.1.1.2.1.9 counter15m read-only
Number of SLIP Second (SS) for the current 15 minute period. SS is defined as one second containing one or more SLIPs
               pmTif15mTable 1.3.6.1.4.1.2928.6.2.17.1.1.3 no-access
Table of 15 minute PM log history
                   pmTif15mEntry 1.3.6.1.4.1.2928.6.2.17.1.1.3.1 no-access
One entry for each 15 minute PM interval
                       pmTif15mIndex 1.3.6.1.4.1.2928.6.2.17.1.1.3.1.1 unsigned32 no-access
The index that identifies the interval for which the set of statistics is available. Index of '0' indicates the most recently completed interval, and the index is increased by one for each interval back in time.
                       pmTif15mTime 1.3.6.1.4.1.2928.6.2.17.1.1.3.1.2 dateandtime read-only
Time stamp for this 15 minute interval
                       pmTif15mSuspect 1.3.6.1.4.1.2928.6.2.17.1.1.3.1.3 truthvalue read-only
Suspect flag for this 15 minute interval
                       pmTif15mZS 1.3.6.1.4.1.2928.6.2.17.1.1.3.1.4 counter32 read-only
Zero Suppression Counter. If the performance monitoring uses zero suppression, this counter specifies how many fault free intervals have preceded the faulty one.
                       pmTif15mESs 1.3.6.1.4.1.2928.6.2.17.1.1.3.1.5 counter15m read-only
Number of Errored Seconds (ES) for this 15 minute period. ES is defined as one second of available time containing one or more Errored Blocks (EB) or at least one defect
                       pmTif15mSESs 1.3.6.1.4.1.2928.6.2.17.1.1.3.1.6 counter15m read-only
Number of Severe Errored Seconds (SES) for this 15 minute period. SES is defined as one second of available time containing more than 30% Errored Blocks (EB) or at least one defect.
                       pmTif15mBBEs 1.3.6.1.4.1.2928.6.2.17.1.1.3.1.7 gauge32 read-only
Number of Background Block Error (BBE) for this 15 minute period. BBE is defined as the number of Errored Blocks (EB) during one second of available time not part of SES
                       pmTif15mUASs 1.3.6.1.4.1.2928.6.2.17.1.1.3.1.8 counter15m read-only
Number of Unavailable Second (UAS) for this 15 minute period. UAS is defined as one second of UAT (Unavailable Time). During UAT calculations of BBE, ES and SES are inhibited and no data collection of them is performed
                       pmTif15mSSs 1.3.6.1.4.1.2928.6.2.17.1.1.3.1.9 counter15m read-only
Number of SLIP Second (SS) for this 15 minute period. SS is defined as one second containing one or more SLIPs
               pmTif24hTable 1.3.6.1.4.1.2928.6.2.17.1.1.4 no-access
Table of 24 hour PM log history
                   pmTif24hEntry 1.3.6.1.4.1.2928.6.2.17.1.1.4.1 no-access
One entry for each 24 hour PM interval
                       pmTif24hIndex 1.3.6.1.4.1.2928.6.2.17.1.1.4.1.1 unsigned32 no-access
The index that identifies the interval for which the set of statistics is available. Index of '0' indicates the most recently completed interval, and the index is increased by one for each interval back in time.
                       pmTif24hTime 1.3.6.1.4.1.2928.6.2.17.1.1.4.1.2 dateandtime read-only
Time stamp for this 24 hour interval
                       pmTif24hSuspect 1.3.6.1.4.1.2928.6.2.17.1.1.4.1.3 truthvalue read-only
Suspect flag for this 24 hour interval
                       pmTif24hZS 1.3.6.1.4.1.2928.6.2.17.1.1.4.1.4 counter32 read-only
Zero Suppression Counter. If the performance monitoring uses zero suppression, this counter specifies how many fault free intervals have preceded the faulty one.
                       pmTif24hESs 1.3.6.1.4.1.2928.6.2.17.1.1.4.1.5 counter24h read-only
Number of Errored Seconds (ES) for this 24 hour period. ES is defined as one second of available time containing one or more Errored Blocks (EB) or at least one defect
                       pmTif24hSESs 1.3.6.1.4.1.2928.6.2.17.1.1.4.1.6 counter24h read-only
Number of Severe Errored Seconds (SES) for this 24 hour period. SES is defined as one second of available time containing more than 30% Errored Blocks (EB) or at least one defect.
                       pmTif24hBBEs 1.3.6.1.4.1.2928.6.2.17.1.1.4.1.7 gauge32 read-only
Number of Background Block Error (BBE) for this 24 hour period. BBE is defined as the number of Errored Blocks (EB) during one second of available time not part of SES
                       pmTif24hUASs 1.3.6.1.4.1.2928.6.2.17.1.1.4.1.8 counter24h read-only
Number of Unavailable Second (UAS) for this 24 hour period. UAS is defined as one second of UAT (Unavailable Time). During UAT calculations of BBE, ES and SES are inhibited and no data collection of them is performed
                       pmTif24hSSs 1.3.6.1.4.1.2928.6.2.17.1.1.4.1.9 counter24h read-only
Number of SLIP Second (SS) for this 24 hour period. SS is defined as one second containing one or more SLIPs
               pmTif24hCurrentTable 1.3.6.1.4.1.2928.6.2.17.1.1.5 no-access
Table of PM data for the current 24 hour period
                   pmTif24hCurrentEntry 1.3.6.1.4.1.2928.6.2.17.1.1.5.1 no-access
One entry for each monitored object
                       pmTif24hCurrentTime 1.3.6.1.4.1.2928.6.2.17.1.1.5.1.2 counter15m read-only
Elapsed time in seconds for the current 24 hour period.
                       pmTif24hCurrentSuspect 1.3.6.1.4.1.2928.6.2.17.1.1.5.1.3 truthvalue read-only
Is Suspect flag, if set to `true(1)' the current 24 hour measurement period has unreliable measurement data.
                       pmTif24hCurrentZS 1.3.6.1.4.1.2928.6.2.17.1.1.5.1.4 counter32 read-only
Zero Suppression Counter. If the performance monitoring uses zero suppression, this counter specifies how many fault free intervals have preceded the faulty one.
                       pmTif24hCurrentESs 1.3.6.1.4.1.2928.6.2.17.1.1.5.1.5 counter15m read-only
Number of Errored Seconds (ES) for the current 24 hour period. ES is defined as one second of available time containing one or more Errored Blocks (EB) or at least one defect
                       pmTif24hCurrentSESs 1.3.6.1.4.1.2928.6.2.17.1.1.5.1.6 counter15m read-only
Number of Severe Errored Seconds (SES) for the current 24 hour period. SES is defined as one second of available time containing more than 30% Errored Blocks (EB) or at least one defect.
                       pmTif24hCurrentBBEs 1.3.6.1.4.1.2928.6.2.17.1.1.5.1.7 gauge32 read-only
Number of Background Block Error (BBE) for the current 24 hour period. BBE is defined as the number of Errored Blocks (EB) during one second of available time not part of SES
                       pmTif24hCurrentUASs 1.3.6.1.4.1.2928.6.2.17.1.1.5.1.8 counter15m read-only
Number of Unavailable Second (UAS) for the current 24 hour period. UAS is defined as one second of UAT (Unavailable Time). During UAT calculations of BBE, ES and SES are inhibited and no data collection of them is performed
                       pmTif24hCurrentSSs 1.3.6.1.4.1.2928.6.2.17.1.1.5.1.9 counter15m read-only
Number of SLIP Second (SS) for the current 24 hour period. SS is defined as one second containing one or more SLIPs
           pmAifGroup 1.3.6.1.4.1.2928.6.2.17.1.2
               pmAifTable 1.3.6.1.4.1.2928.6.2.17.1.2.1 no-access
Table of Performance Monitored access interfaces
                   pmAifEntry 1.3.6.1.4.1.2928.6.2.17.1.2.1.1 no-access
One entry for each access interface
                       pmAifIndex 1.3.6.1.4.1.2928.6.2.17.1.2.1.1.1 unsigned32 no-access
The index uniquely identifying this access interface.
                       pmAifAdminStatus 1.3.6.1.4.1.2928.6.2.17.1.2.1.1.2 integer read-write
The desired state of the PM function. Affects the operative state of the PM object Enumeration: 'down': 2, 'up': 1.
                       pmAifOperStatus 1.3.6.1.4.1.2928.6.2.17.1.2.1.1.3 integer read-only
PM operative state. Enumeration: 'down': 2, 'up': 1.
                       pmAifFailure 1.3.6.1.4.1.2928.6.2.17.1.2.1.1.4 displaystring read-only
Shows current failure state. An empty string indicates no failure
                       pmAifDataSource 1.3.6.1.4.1.2928.6.2.17.1.2.1.1.5 object identifier read-only
The PM Data Source object
                       pmAifDataSourceName 1.3.6.1.4.1.2928.6.2.17.1.2.1.1.6 displaystring read-only
The name of the PM Data Source
                       pmAifUatAlarmsEnabled 1.3.6.1.4.1.2928.6.2.17.1.2.1.1.7 truthvalue read-write
If set to `true(1)' then UAT alarms will be sent. Unavailable time (UAT) defines a state where a service is unable to perform its normal task due to severe errors for a longer period. It begins at detection of ten consecutive SES events and ends at detection of ten consecutive non-SES events. In both cases, the 10s are considered part of unavailable respective available time and effects the visibility of G.826 PM events (they are delayed 10s) Entry and exit of UAT is declared by raising and clearing an UAT alarm (if enabled)
                       pmAifTresholdAlarmsEnabled 1.3.6.1.4.1.2928.6.2.17.1.2.1.1.8 truthvalue read-write
If set to `true(1)' then threshold alarms will be sent. Each 15m and 24h current register counter can be assigned a threshold value. When crossed, a threshold crossing alarm will be sent for the interval if enabled. Raised alarm will be cleared at end of a following fault free interval i.e. one with all interval counter values below their threshold values and with no UAT. Only one TC alarm per interval can be raised, regardless of how many thresholds have been crossed.
                       pmAifPeriodicEventsEnabled 1.3.6.1.4.1.2928.6.2.17.1.2.1.1.9 truthvalue read-write
If set to `true(1)' then History Periodic Events will be sent.
                       pmAifZeroSuppressionEnabled 1.3.6.1.4.1.2928.6.2.17.1.2.1.1.10 truthvalue read-write
If set to `true(1)' then Zero Suppression mode is enabled Zero Suppression mode tells whether intervals with all current counters equal to zero shall be stored in the history log or not. If enabled, once a faulty interval is found, its current register content including a zero suppressed interval counter will be stored in the history log. The additional counter specifies how many fault free intervals have preceded the faulty one. In such way, history for a larger measurement period can be logged than would otherwise be possible
                       pmAifHistorySize 1.3.6.1.4.1.2928.6.2.17.1.2.1.1.11 integer read-write
The size of the history log Enumeration: 'small': 2, 'large': 3, 'none': 1.
                       pmAif15mTresholdES 1.3.6.1.4.1.2928.6.2.17.1.2.1.1.12 counter15m read-write
15 minute threshold value for ES. Current ES value equal to or above this threshold will raise a threshold alarm if enabled. A value of zero will disable threshold check.
                       pmAif15mTresholdSES 1.3.6.1.4.1.2928.6.2.17.1.2.1.1.13 counter15m read-write
15 minute threshold value for SES. Current SES value equal to or above this threshold will raise a threshold alarm if enabled. A value of zero will disable threshold check.
                       pmAif15mTresholdBBE 1.3.6.1.4.1.2928.6.2.17.1.2.1.1.14 gauge32 read-write
15 minute threshold value for BBE. Current BBE value equal to or above this threshold will raise a threshold alarm if enabled. A value of zero will disable threshold check.
                       pmAif24hTresholdES 1.3.6.1.4.1.2928.6.2.17.1.2.1.1.15 counter24h read-write
24 hour threshold value for ES. Current ES value equal to or above this threshold will raise a threshold alarm if enabled. A value of zero will disable threshold check.
                       pmAif24hTresholdSES 1.3.6.1.4.1.2928.6.2.17.1.2.1.1.16 counter24h read-write
24 hour threshold value for SES. Current SES value equal to or above this threshold will raise a threshold alarm if enabled. A value of zero will disable threshold check.
                       pmAif24hTresholdBBE 1.3.6.1.4.1.2928.6.2.17.1.2.1.1.17 gauge32 read-write
24 hour threshold value for BBE. Current BBE value equal to or above this threshold will raise a threshold alarm if enabled. A value of zero will disable threshold check.
               pmAifCurrentTable 1.3.6.1.4.1.2928.6.2.17.1.2.2 no-access
Table of PM data for the current 15 minute period
                   pmAifCurrentEntry 1.3.6.1.4.1.2928.6.2.17.1.2.2.1 no-access
One entry for each monitored object
                       pmAifCurrentTime 1.3.6.1.4.1.2928.6.2.17.1.2.2.1.2 counter15m read-only
Elapsed time in seconds for the current 15 minute period.
                       pmAifCurrentSuspect 1.3.6.1.4.1.2928.6.2.17.1.2.2.1.3 truthvalue read-only
Is Suspect flag, if set to `true(1)' the current 15 minute measurement period has unreliable measurement data.
                       pmAifCurrentZS 1.3.6.1.4.1.2928.6.2.17.1.2.2.1.4 counter32 read-only
Zero Suppression Counter. If the performance monitoring uses zero suppression, this counter specifies how many fault free intervals have preceded the faulty one.
                       pmAifCurrentESs 1.3.6.1.4.1.2928.6.2.17.1.2.2.1.5 counter15m read-only
Number of Errored Seconds (ES) for the current 15 minute period. ES is defined as one second of available time containing one or more Errored Blocks (EB) or at least one defect
                       pmAifCurrentSESs 1.3.6.1.4.1.2928.6.2.17.1.2.2.1.6 counter15m read-only
Number of Severe Errored Seconds (SES) for the current 15 minute period. SES is defined as one second of available time containing more than 30% Errored Blocks (EB) or at least one defect.
                       pmAifCurrentBBEs 1.3.6.1.4.1.2928.6.2.17.1.2.2.1.7 gauge32 read-only
Number of Background Block Error (BBE) for the current 15 minute period. BBE is defined as the number of Errored Blocks (EB) during one second of available time not part of SES
                       pmAifCurrentUASs 1.3.6.1.4.1.2928.6.2.17.1.2.2.1.8 counter15m read-only
Number of Unavailable Second (UAS) for the current 15 minute period. UAS is defined as one second of UAT (Unavailable Time). During UAT calculations of BBE, ES and SES are inhibited and no data collection of them is performed
               pmAif15mTable 1.3.6.1.4.1.2928.6.2.17.1.2.3 no-access
Table of 15 minute PM interval history
                   pmAif15mEntry 1.3.6.1.4.1.2928.6.2.17.1.2.3.1 no-access
One entry for each 15 minute PM interval
                       pmAif15mIndex 1.3.6.1.4.1.2928.6.2.17.1.2.3.1.1 unsigned32 no-access
The index that identifies the interval for which the set of statistics is available. Index of '0' indicates the most recently completed interval, and the index is increased by one for each interval back in time.
                       pmAif15mTime 1.3.6.1.4.1.2928.6.2.17.1.2.3.1.2 dateandtime read-only
Time stamp for this 15 minute interval
                       pmAif15mSuspect 1.3.6.1.4.1.2928.6.2.17.1.2.3.1.3 truthvalue read-only
Suspect flag for this 15 minute interval
                       pmAif15mZS 1.3.6.1.4.1.2928.6.2.17.1.2.3.1.4 counter32 read-only
Zero Suppression Counter. If the performance monitoring uses zero suppression, this counter specifies how many fault free intervals have preceded the faulty one.
                       pmAif15mESs 1.3.6.1.4.1.2928.6.2.17.1.2.3.1.5 counter15m read-only
Number of Errored Seconds (ES) for this 15 minute period. ES is defined as one second of available time containing one or more Errored Blocks (EB) or at least one defect
                       pmAif15mSESs 1.3.6.1.4.1.2928.6.2.17.1.2.3.1.6 counter15m read-only
Number of Severe Errored Seconds (SES) for this 15 minute period. SES is defined as one second of available time containing more than 30% Errored Blocks (EB) or at least one defect.
                       pmAif15mBBEs 1.3.6.1.4.1.2928.6.2.17.1.2.3.1.7 gauge32 read-only
Number of Background Block Error (BBE) for this 15 minute period. BBE is defined as the number of Errored Blocks (EB) during one second of available time not part of SES
                       pmAif15mUASs 1.3.6.1.4.1.2928.6.2.17.1.2.3.1.8 counter15m read-only
Number of Unavailable Second (UAS) for this 15 minute period. UAS is defined as one second of UAT (Unavailable Time). During UAT calculations of BBE, ES and SES are inhibited and no data collection of them is performed
               pmAif24hTable 1.3.6.1.4.1.2928.6.2.17.1.2.4 no-access
Table of 24 hour PM log history
                   pmAif24hEntry 1.3.6.1.4.1.2928.6.2.17.1.2.4.1 no-access
One entry for each 24 hour PM interval
                       pmAif24hIndex 1.3.6.1.4.1.2928.6.2.17.1.2.4.1.1 unsigned32 no-access
The index that identifies the interval for which the set of statistics is available. Index of '0' indicates the most recently completed interval, and the index is increased by one for each interval back in time.
                       pmAif24hTime 1.3.6.1.4.1.2928.6.2.17.1.2.4.1.2 dateandtime read-only
Time stamp for this 24 hour interval
                       pmAif24hSuspect 1.3.6.1.4.1.2928.6.2.17.1.2.4.1.3 truthvalue read-only
Suspect flag for this 24 hour interval
                       pmAif24hZS 1.3.6.1.4.1.2928.6.2.17.1.2.4.1.4 counter32 read-only
Zero Suppression Counter. If the performance monitoring uses zero suppression, this counter specifies how many fault free intervals have preceded the faulty one.
                       pmAif24hESs 1.3.6.1.4.1.2928.6.2.17.1.2.4.1.5 counter24h read-only
Number of Errored Seconds (ES) for this 24 hour period. ES is defined as one second of available time containing one or more Errored Blocks (EB) or at least one defect
                       pmAif24hSESs 1.3.6.1.4.1.2928.6.2.17.1.2.4.1.6 counter24h read-only
Number of Severe Errored Seconds (SES) for this 24 hour period. SES is defined as one second of available time containing more than 30% Errored Blocks (EB) or at least one defect.
                       pmAif24hBBEs 1.3.6.1.4.1.2928.6.2.17.1.2.4.1.7 gauge32 read-only
Number of Background Block Error (BBE) for this 24 hour period. BBE is defined as the number of Errored Blocks (EB) during one second of available time not part of SES
                       pmAif24hUASs 1.3.6.1.4.1.2928.6.2.17.1.2.4.1.8 counter24h read-only
Number of Unavailable Second (UAS) for this 24 hour period. UAS is defined as one second of UAT (Unavailable Time). During UAT calculations of BBE, ES and SES are inhibited and no data collection of them is performed
               pmAif24hCurrentTable 1.3.6.1.4.1.2928.6.2.17.1.2.5 no-access
Table of PM data for the current 24 hour period
                   pmAif24hCurrentEntry 1.3.6.1.4.1.2928.6.2.17.1.2.5.1 no-access
One entry for each monitored object
                       pmAif24hCurrentTime 1.3.6.1.4.1.2928.6.2.17.1.2.5.1.2 counter15m read-only
Elapsed time in seconds for the current 24 hour period.
                       pmAif24hCurrentSuspect 1.3.6.1.4.1.2928.6.2.17.1.2.5.1.3 truthvalue read-only
Is Suspect flag, if set to `true(1)' the current 24 hour measurement period has unreliable measurement data.
                       pmAif24hCurrentZS 1.3.6.1.4.1.2928.6.2.17.1.2.5.1.4 counter32 read-only
Zero Suppression Counter. If the performance monitoring uses zero suppression, this counter specifies how many fault free intervals have preceded the faulty one.
                       pmAif24hCurrentESs 1.3.6.1.4.1.2928.6.2.17.1.2.5.1.5 counter15m read-only
Number of Errored Seconds (ES) for the current 24 hour period. ES is defined as one second of available time containing one or more Errored Blocks (EB) or at least one defect
                       pmAif24hCurrentSESs 1.3.6.1.4.1.2928.6.2.17.1.2.5.1.6 counter15m read-only
Number of Severe Errored Seconds (SES) for the current 24 hour period. SES is defined as one second of available time containing more than 30% Errored Blocks (EB) or at least one defect.
                       pmAif24hCurrentBBEs 1.3.6.1.4.1.2928.6.2.17.1.2.5.1.7 gauge32 read-only
Number of Background Block Error (BBE) for the current 24 hour period. BBE is defined as the number of Errored Blocks (EB) during one second of available time not part of SES
                       pmAif24hCurrentUASs 1.3.6.1.4.1.2928.6.2.17.1.2.5.1.8 counter15m read-only
Number of Unavailable Second (UAS) for the current 24 hour period. UAS is defined as one second of UAT (Unavailable Time). During UAT calculations of BBE, ES and SES are inhibited and no data collection of them is performed
           pmDchGroup 1.3.6.1.4.1.2928.6.2.17.1.3
               pmDchTable 1.3.6.1.4.1.2928.6.2.17.1.3.1 no-access
Table of Performance Monitored DTM channel
                   pmDchEntry 1.3.6.1.4.1.2928.6.2.17.1.3.1.1 no-access
One entry for each DTM channel
                       pmDchIndex 1.3.6.1.4.1.2928.6.2.17.1.3.1.1.1 unsigned32 no-access
The index uniquely identifying this DTM channel.
                       pmDchAdminStatus 1.3.6.1.4.1.2928.6.2.17.1.3.1.1.2 integer read-write
The desired state of the PM function. Affects the operative state of the PM object Enumeration: 'down': 2, 'up': 1.
                       pmDchOperStatus 1.3.6.1.4.1.2928.6.2.17.1.3.1.1.3 integer read-only
PM operative state. Enumeration: 'down': 2, 'up': 1.
                       pmDchFailure 1.3.6.1.4.1.2928.6.2.17.1.3.1.1.4 displaystring read-only
Shows current failure state. An empty string indicates no failure
                       pmDchDataSource 1.3.6.1.4.1.2928.6.2.17.1.3.1.1.5 object identifier read-only
The PM Data Source object
                       pmDchDataSourceName 1.3.6.1.4.1.2928.6.2.17.1.3.1.1.6 displaystring read-only
The name of the PM Data Source
                       pmDchUatAlarmsEnabled 1.3.6.1.4.1.2928.6.2.17.1.3.1.1.7 truthvalue read-write
If set to `true(1)' then UAT alarms will be sent. Unavailable time (UAT) defines a state where a service is unable to perform its normal task due to severe errors for a longer period. It begins at detection of ten consecutive SES events and ends at detection of ten consecutive non-SES events. In both cases, the 10s are considered part of unavailable respective available time and effects the visibility of G.826 PM events (they are delayed 10s) Entry and exit of UAT is declared by raising and clearing an UAT alarm (if enabled)
                       pmDchTresholdAlarmsEnabled 1.3.6.1.4.1.2928.6.2.17.1.3.1.1.8 truthvalue read-write
If set to `true(1)' then threshold alarms will be sent. Each 15m and 24h current register counter can be assigned a threshold value. When crossed, a threshold crossing alarm will be sent for the interval if enabled. Raised alarm will be cleared at end of a following fault free interval i.e. one with all interval counter values below their threshold values and with no UAT. Only one TC alarm per interval can be raised, regardless of how many thresholds have been crossed.
                       pmDchPeriodicEventsEnabled 1.3.6.1.4.1.2928.6.2.17.1.3.1.1.9 truthvalue read-write
If set to `true(1)' then History Periodic Events will be sent.
                       pmDchZeroSuppressionEnabled 1.3.6.1.4.1.2928.6.2.17.1.3.1.1.10 truthvalue read-write
If set to `true(1)' then Zero Suppression mode is enabled Zero Suppression mode tells whether intervals with all current counters equal to zero shall be stored in the history log or not. If enabled, once a faulty interval is found, its current register content including a zero suppressed interval counter will be stored in the history log. The additional counter specifies how many fault free intervals have preceded the faulty one. In such way, history for a larger measurement period can be logged than would otherwise be possible
                       pmDchHistorySize 1.3.6.1.4.1.2928.6.2.17.1.3.1.1.11 integer read-write
The size of the history log Enumeration: 'small': 2, 'large': 3, 'none': 1.
                       pmDch15mTresholdES 1.3.6.1.4.1.2928.6.2.17.1.3.1.1.12 counter15m read-write
15 minute threshold value for ES. Current ES value equal to or above this threshold will raise a threshold alarm if enabled. A value of zero will disable threshold check.
                       pmDch15mTresholdSES 1.3.6.1.4.1.2928.6.2.17.1.3.1.1.13 counter15m read-write
15 minute threshold value for SES. Current SES value equal to or above this threshold will raise a threshold alarm if enabled. A value of zero will disable threshold check.
                       pmDch15mTresholdBBE 1.3.6.1.4.1.2928.6.2.17.1.3.1.1.14 gauge32 read-write
15 minute threshold value for BBE. Current BBE value equal to or above this threshold will raise a threshold alarm if enabled. A value of zero will disable threshold check.
                       pmDch24hTresholdES 1.3.6.1.4.1.2928.6.2.17.1.3.1.1.15 counter24h read-write
24 hour threshold value for ES. Current ES value equal to or above this threshold will raise a threshold alarm if enabled. A value of zero will disable threshold check.
                       pmDch24hTresholdSES 1.3.6.1.4.1.2928.6.2.17.1.3.1.1.16 counter24h read-write
24 hour threshold value for SES. Current SES value equal to or above this threshold will raise a threshold alarm if enabled. A value of zero will disable threshold check.
                       pmDch24hTresholdBBE 1.3.6.1.4.1.2928.6.2.17.1.3.1.1.17 gauge32 read-write
24 hour threshold value for BBE. Current BBE value equal to or above this threshold will raise a threshold alarm if enabled. A value of zero will disable threshold check.
               pmDchCurrentTable 1.3.6.1.4.1.2928.6.2.17.1.3.2 no-access
Table of PM data for the current 15 minute period
                   pmDchCurrentEntry 1.3.6.1.4.1.2928.6.2.17.1.3.2.1 no-access
One entry for each monitored object
                       pmDchCurrentTime 1.3.6.1.4.1.2928.6.2.17.1.3.2.1.2 counter15m read-only
Elapsed time in seconds for the current 15 minute period.
                       pmDchCurrentSuspect 1.3.6.1.4.1.2928.6.2.17.1.3.2.1.3 truthvalue read-only
Is Suspect flag, if set to `true(1)' the current 15 minute measurement period has unreliable measurement data.
                       pmDchCurrentZS 1.3.6.1.4.1.2928.6.2.17.1.3.2.1.4 counter32 read-only
Zero Suppression Counter. If the performance monitoring uses zero suppression, this counter specifies how many fault free intervals have preceded the faulty one.
                       pmDchCurrentESs 1.3.6.1.4.1.2928.6.2.17.1.3.2.1.5 counter15m read-only
Number of Errored Seconds (ES) for the current 15 minute period. ES is defined as one second of available time containing one or more Errored Blocks (EB) or at least one defect
                       pmDchCurrentSESs 1.3.6.1.4.1.2928.6.2.17.1.3.2.1.6 counter15m read-only
Number of Severe Errored Seconds (SES) for the current 15 minute period. SES is defined as one second of available time containing more than 30% Errored Blocks (EB) or at least one defect.
                       pmDchCurrentBBEs 1.3.6.1.4.1.2928.6.2.17.1.3.2.1.7 gauge32 read-only
Number of Background Block Error (BBE) for the current 15 minute period. BBE is defined as the number of Errored Blocks (EB) during one second of available time not part of SES
                       pmDchCurrentUASs 1.3.6.1.4.1.2928.6.2.17.1.3.2.1.8 counter15m read-only
Number of Unavailable Second (UAS) for the current 15 minute period. UAS is defined as one second of UAT (Unavailable Time). During UAT calculations of BBE, ES and SES are inhibited and no data collection of them is performed
               pmDch15mTable 1.3.6.1.4.1.2928.6.2.17.1.3.3 no-access
Table of 15 minute PM interval history
                   pmDch15mEntry 1.3.6.1.4.1.2928.6.2.17.1.3.3.1 no-access
One entry for each 15 minute PM interval
                       pmDch15mIndex 1.3.6.1.4.1.2928.6.2.17.1.3.3.1.1 unsigned32 no-access
The index that identifies the interval for which the set of statistics is available. Index of '0' indicates the most recently completed interval, and the index is increased by one for each interval back in time.
                       pmDch15mTime 1.3.6.1.4.1.2928.6.2.17.1.3.3.1.2 dateandtime read-only
Time stamp for this 15 minute interval
                       pmDch15mSuspect 1.3.6.1.4.1.2928.6.2.17.1.3.3.1.3 truthvalue read-only
Suspect flag for this 15 minute interval
                       pmDch15mZS 1.3.6.1.4.1.2928.6.2.17.1.3.3.1.4 counter32 read-only
Zero Suppression Counter. If the performance monitoring uses zero suppression, this counter specifies how many fault free intervals have preceded the faulty one.
                       pmDch15mESs 1.3.6.1.4.1.2928.6.2.17.1.3.3.1.5 counter15m read-only
Number of Errored Seconds (ES) for this 15 minute period. ES is defined as one second of available time containing one or more Errored Blocks (EB) or at least one defect
                       pmDch15mSESs 1.3.6.1.4.1.2928.6.2.17.1.3.3.1.6 counter15m read-only
Number of Severe Errored Seconds (SES) for this 15 minute period. SES is defined as one second of available time containing more than 30% Errored Blocks (EB) or at least one defect.
                       pmDch15mBBEs 1.3.6.1.4.1.2928.6.2.17.1.3.3.1.7 gauge32 read-only
Number of Background Block Error (BBE) for this 15 minute period. BBE is defined as the number of Errored Blocks (EB) during one second of available time not part of SES
                       pmDch15mUASs 1.3.6.1.4.1.2928.6.2.17.1.3.3.1.8 counter15m read-only
Number of Unavailable Second (UAS) for this 15 minute period. UAS is defined as one second of UAT (Unavailable Time). During UAT calculations of BBE, ES and SES are inhibited and no data collection of them is performed
               pmDch24hTable 1.3.6.1.4.1.2928.6.2.17.1.3.4 no-access
Table of 24 hour PM interval history
                   pmDch24hEntry 1.3.6.1.4.1.2928.6.2.17.1.3.4.1 no-access
One entry for each 24 hour PM interval
                       pmDch24hIndex 1.3.6.1.4.1.2928.6.2.17.1.3.4.1.1 unsigned32 no-access
The index that identifies the interval for which the set of statistics is available. Index of '0' indicates the most recently completed interval, and the index is increased by one for each interval back in time.
                       pmDch24hTime 1.3.6.1.4.1.2928.6.2.17.1.3.4.1.2 dateandtime read-only
Time stamp for this 24 hour interval
                       pmDch24hSuspect 1.3.6.1.4.1.2928.6.2.17.1.3.4.1.3 truthvalue read-only
Suspect flag for this 24 hour interval
                       pmDch24hZS 1.3.6.1.4.1.2928.6.2.17.1.3.4.1.4 counter32 read-only
Zero Suppression Counter. If the performance monitoring uses zero suppression, this counter specifies how many fault free intervals have preceded the faulty one.
                       pmDch24hESs 1.3.6.1.4.1.2928.6.2.17.1.3.4.1.5 counter24h read-only
Number of Errored Seconds (ES) for this 24 hour period. ES is defined as one second of available time containing one or more Errored Blocks (EB) or at least one defect
                       pmDch24hSESs 1.3.6.1.4.1.2928.6.2.17.1.3.4.1.6 counter24h read-only
Number of Severe Errored Seconds (SES) for this 24 hour period. SES is defined as one second of available time containing more than 30% Errored Blocks (EB) or at least one defect.
                       pmDch24hBBEs 1.3.6.1.4.1.2928.6.2.17.1.3.4.1.7 gauge32 read-only
Number of Background Block Error (BBE) for this 24 hour period. BBE is defined as the number of Errored Blocks (EB) during one second of available time not part of SES
                       pmDch24hUASs 1.3.6.1.4.1.2928.6.2.17.1.3.4.1.8 counter24h read-only
Number of Unavailable Second (UAS) for this 24 hour period. UAS is defined as one second of UAT (Unavailable Time). During UAT calculations of BBE, ES and SES are inhibited and no data collection of them is performed
               pmDch24hCurrentTable 1.3.6.1.4.1.2928.6.2.17.1.3.5 no-access
Table of PM data for the current 24 hour period
                   pmDch24hCurrentEntry 1.3.6.1.4.1.2928.6.2.17.1.3.5.1 no-access
One entry for each monitored object
                       pmDch24hCurrentTime 1.3.6.1.4.1.2928.6.2.17.1.3.5.1.2 counter15m read-only
Elapsed time in seconds for the current 24 hour period.
                       pmDch24hCurrentSuspect 1.3.6.1.4.1.2928.6.2.17.1.3.5.1.3 truthvalue read-only
Is Suspect flag, if set to `true(1)' the current 24 hour measurement period has unreliable measurement data.
                       pmDch24hCurrentZS 1.3.6.1.4.1.2928.6.2.17.1.3.5.1.4 counter32 read-only
Zero Suppression Counter. If the performance monitoring uses zero suppression, this counter specifies how many fault free intervals have preceded the faulty one.
                       pmDch24hCurrentESs 1.3.6.1.4.1.2928.6.2.17.1.3.5.1.5 counter15m read-only
Number of Errored Seconds (ES) for the current 24 hour period. ES is defined as one second of available time containing one or more Errored Blocks (EB) or at least one defect
                       pmDch24hCurrentSESs 1.3.6.1.4.1.2928.6.2.17.1.3.5.1.6 counter15m read-only
Number of Severe Errored Seconds (SES) for the current 24 hour period. SES is defined as one second of available time containing more than 30% Errored Blocks (EB) or at least one defect.
                       pmDch24hCurrentBBEs 1.3.6.1.4.1.2928.6.2.17.1.3.5.1.7 gauge32 read-only
Number of Background Block Error (BBE) for the current 24 hour period. BBE is defined as the number of Errored Blocks (EB) during one second of available time not part of SES
                       pmDch24hCurrentUASs 1.3.6.1.4.1.2928.6.2.17.1.3.5.1.8 counter15m read-only
Number of Unavailable Second (UAS) for the current 24 hour period. UAS is defined as one second of UAT (Unavailable Time). During UAT calculations of BBE, ES and SES are inhibited and no data collection of them is performed
           pmConformanceGroups 1.3.6.1.4.1.2928.6.2.17.1.4
               pmTifConformanceGroup 1.3.6.1.4.1.2928.6.2.17.1.4.1
The PM Trunk Interface Conformance Group.
               pmAifConformanceGroup 1.3.6.1.4.1.2928.6.2.17.1.4.2
The PM Access Interface Conformance Group.
               pmDchConformanceGroup 1.3.6.1.4.1.2928.6.2.17.1.4.3
The PM Channel Conformance Group.