NETGEAR-BOXSERVICES-PRIVATE-MIB: View SNMP OID List / Download MIB

VENDOR: NETGEAR


 Home MIB: NETGEAR-BOXSERVICES-PRIVATE-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 fastPathBoxServices 1.3.6.1.4.1.4526.10.43
The Netgear Private MIB for NETGEAR Box Services Feature.
       fastPathBoxServicesTraps 1.3.6.1.4.1.4526.10.43.0
           boxsFanStateChange 1.3.6.1.4.1.4526.10.43.0.1
Trap is sent when fan state change happens.
           boxsPowSupplyStateChange 1.3.6.1.4.1.4526.10.43.0.2
Trap is sent when power supply state change happens.
           boxsTemperatureChange 1.3.6.1.4.1.4526.10.43.0.3
Trap is sent when temperature is changing and crossing any of the thresholds
           boxsThermalShutdown 1.3.6.1.4.1.4526.10.43.0.4
Trap is sent when thermal shutdown is initiated.
           boxsTemperatureStateChange 1.3.6.1.4.1.4526.10.43.0.5
Trap is sent when the system temperature crosses a threshold. To avoid rapid flapping between states, a hysteresis may be applied.
       boxServicesGroup 1.3.6.1.4.1.4526.10.43.1
           boxServicesNormalTempRangeMin 1.3.6.1.4.1.4526.10.43.1.1 integer32 read-write
Lower boundary of normal temperature range.
           boxServicesNormalTempRangeMax 1.3.6.1.4.1.4526.10.43.1.2 integer32 read-write
Upper boundary of normal temperature range.
           boxServicesTemperatureTrapEnable 1.3.6.1.4.1.4526.10.43.1.3 integer read-write
Enable or disable temperature change event trap, raised when temperature crosses boundaries of normal range Enumeration: 'enable': 1, 'disable': 2.
           boxServicesPSMStateTrapEnable 1.3.6.1.4.1.4526.10.43.1.4 integer read-write
Enable or disable Power Supply Module state change trap. Enumeration: 'enable': 1, 'disable': 2.
           boxServicesFanStateTrapEnable 1.3.6.1.4.1.4526.10.43.1.5 integer read-write
Enable or disable Fan state change trap. Enumeration: 'enable': 1, 'disable': 2.
           boxServicesFansTable 1.3.6.1.4.1.4526.10.43.1.6 no-access
Fan
               boxServicesFansEntry 1.3.6.1.4.1.4526.10.43.1.6.1 no-access
Box Services Fan Entry
                   boxServicesFansIndex 1.3.6.1.4.1.4526.10.43.1.6.1.1 integer32 read-only
Unique index of fan table entry
                   boxServicesFanItemType 1.3.6.1.4.1.4526.10.43.1.6.1.2 integer read-only
The type of fan Enumeration: 'removableDC': 4, 'fixedAC': 3, 'removable': 2, 'fixed': 1, 'removableAC': 6, 'fixedDC': 5.
                   boxServicesFanItemState 1.3.6.1.4.1.4526.10.43.1.6.1.3 integer read-only
The status of fan. nopower(4) - This state means the fan is present but no AC is connected. Enumeration: 'powering': 4, 'incompatible': 7, 'nopower': 5, 'operational': 2, 'notpowering': 6, 'notpresent': 1, 'failed': 3.
                   boxServicesFanSpeed 1.3.6.1.4.1.4526.10.43.1.6.1.4 octet string read-only
The speed of fan
                   boxServicesFanDutyLevel 1.3.6.1.4.1.4526.10.43.1.6.1.5 octet string read-only
The duty level of fan, in percents
                   boxServicesFanUnitIndex 1.3.6.1.4.1.4526.10.43.1.6.1.6 unsigned32 read-only
Unit index for an entry in the Box Services Fan Table
           boxServicesPowSuppliesTable 1.3.6.1.4.1.4526.10.43.1.7 no-access
Power supply
               boxServicesPowSuppliesEntry 1.3.6.1.4.1.4526.10.43.1.7.1 no-access
Box Services Power Supply Entry
                   boxServicesPowSupplyIndex 1.3.6.1.4.1.4526.10.43.1.7.1.1 integer32 read-only
Unique index of power supply table entry
                   boxServicesPowSupplyItemType 1.3.6.1.4.1.4526.10.43.1.7.1.2 integer read-only
The type of power supply Enumeration: 'removableDC': 4, 'fixedAC': 3, 'removable': 2, 'fixed': 1, 'removableAC': 6, 'fixedDC': 5.
                   boxServicesPowSupplyItemState 1.3.6.1.4.1.4526.10.43.1.7.1.3 integer read-only
The status of power supply. nopower(5) - This state means the power supply is present but no AC is connected. incompatible(7) - This state is possible on boards capable of pluggable Power supplies Enumeration: 'powering': 4, 'incompatible': 7, 'nopower': 5, 'operational': 2, 'notpowering': 6, 'notpresent': 1, 'failed': 3.
                   boxServicesPowerSuppUnitIndex 1.3.6.1.4.1.4526.10.43.1.7.1.4 unsigned32 read-only
Unit index for an entry in the Box Services Power Supply Table
           boxServicesTempSensorsTable 1.3.6.1.4.1.4526.10.43.1.8 no-access
Temperature sensor
               boxServicesTempSensorsEntry 1.3.6.1.4.1.4526.10.43.1.8.1 no-access
Box Services Temperature Sensor Entry
                   boxServicesUnitIndex 1.3.6.1.4.1.4526.10.43.1.8.1.1 unsigned32 read-only
Unit index for an entry in the Box Services Temperature Sensor Table
                   boxServicesTempSensorIndex 1.3.6.1.4.1.4526.10.43.1.8.1.2 unsigned32 read-only
Unique index of temperature sensor table entry
                   boxServicesTempSensorType 1.3.6.1.4.1.4526.10.43.1.8.1.3 integer read-only
The type of temperature sensor Enumeration: 'removableDC': 4, 'fixedAC': 3, 'removable': 2, 'fixed': 1, 'removableAC': 6, 'fixedDC': 5.
                   boxServicesTempSensorState 1.3.6.1.4.1.4526.10.43.1.8.1.4 boxstemperaturestatus read-only
The state of temperature sensor
                   boxServicesTempSensorTemperature 1.3.6.1.4.1.4526.10.43.1.8.1.5 integer32 read-only
The temperature value reported by sensor
           boxServicesThermalShutdownSensor 1.3.6.1.4.1.4526.10.43.1.13 unsigned32 no-access
The number of the sensor which initiated thermal shutdown.
           boxServicesThermalShutdownTemperature 1.3.6.1.4.1.4526.10.43.1.14 unsigned32 no-access
The temperature of the sensor which initiated thermal shutdown.
           boxServicesTempUnitTable 1.3.6.1.4.1.4526.10.43.1.15 no-access
Temperature status table
                 boxServicesTempUnitEntry 1.3.6.1.4.1.4526.10.43.1.15.1 no-access
Box Services Temperature Unit Entry
                     boxServicesTempUnitIndex 1.3.6.1.4.1.4526.10.43.1.15.1.1 unsigned32 read-only
Unit index for an entry in the Box Services Temperature Unit Table
                     boxServicesTempUnitState 1.3.6.1.4.1.4526.10.43.1.15.1.2 boxstemperaturestatus read-only
The temperature state of the unit
                     boxServicesTempUnitTemperature 1.3.6.1.4.1.4526.10.43.1.15.1.3 integer32 read-only
The highest temperature currently reported by any sensor on the unit
       boxServicesNotificationsGroup 1.3.6.1.4.1.4526.10.43.2
           boxsItemStateChangeEvent 1.3.6.1.4.1.4526.10.43.2.1 integer no-access
This event describes states of the fan or power supply. insertion - hot-pluggable fan or power supply was inserted removal - hot-pluggable fan or power supply was removed becomeoperational - fan or power supply became operational after failure state failure - fan or power supply failure happened, i.e. it is not able to perform its functions losepower - a power supply was operational, but the power to it has been disconnected or has failed Enumeration: 'becomeoperational': 3, 'failure': 4, 'removal': 2, 'insertion': 1, 'losepower': 5.
           boxsTemperatureChangeEvent 1.3.6.1.4.1.4526.10.43.2.2 integer no-access
This event describes change of the temperature. To avoid flipping on boundary conditions, it is allowed to send the trap taking into account some margin around thresholds. abovethreshold - temperature increased and crossed upper threshold value belowthreshold - temperature decreased and crossed lower threshold value withinnormalrange - temperature returned to normal range (between threshold) Enumeration: 'abovethreshold': 1, 'belowthreshold': 2, 'withinnormalrange': 3.
           boxsTemperatureStatusCurrentEvent 1.3.6.1.4.1.4526.10.43.2.3 boxstemperaturestatus no-access
This event describes the current status of a switch.
           boxsTemperatureStatusPreviousEvent 1.3.6.1.4.1.4526.10.43.2.4 boxstemperaturestatus no-access
This event describes the previous status of a switch.
       boxsLocatorLedConfigGroup 1.3.6.1.4.1.4526.10.43.4
           boxsLocatorLedUnit 1.3.6.1.4.1.4526.10.43.4.1 integer read-write
Spesifies unit number where Locator LED should blink on. This is write-only value. It always returns '0' on request if the Locator Led feature is supported.
           boxsLocatorLedTime 1.3.6.1.4.1.4526.10.43.4.2 integer read-write
Indicates time period in seconds for Locator LED blinking. The range is from 20 to 3600 seconds. The dafault value is 20 seconds. This is write-only value. It always returns '0' on request if the Locator Led feature is supported.
           boxsLocatorLedEnable 1.3.6.1.4.1.4526.10.43.4.3 integer read-write
Starts the Locator LED blinking. If boxsLocatorLedUnit has not been set current(manager) unit number will be used. If boxsLocatorLedTime has not been set default value(20 seconds) will be used. This is write-only value. It always returns '0' on request if the Locator Led feature is supported. Enumeration: 'enable': 1, 'disable': 0.