Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
netBotz | 1.3.6.1.4.1.5528 | |||
netBotz_reg | 1.3.6.1.4.1.5528.10 | |||
netBotz_generic | 1.3.6.1.4.1.5528.20 | |||
netBotz_products | 1.3.6.1.4.1.5528.30 | |||
netBotz_prd_bot | 1.3.6.1.4.1.5528.30.10 | |||
netBotz_prd_bot_temp | 1.3.6.1.4.1.5528.30.10.1 | integer | read-only |
The reading of the temperature probe, in degrees F or degrees C (depends on netBotz-ismetric). |
netBotz_prd_bot_humidity | 1.3.6.1.4.1.5528.30.10.2 | integer | read-only |
The reading of the humidity probe, in percent. |
netBotz_prd_bot_airflow | 1.3.6.1.4.1.5528.30.10.3 | integer | read-only |
The reading of the airflow probe. Each unit represents approximately 40 feet/minute or 13 meters/minute of airflow velocity. |
netBotz_prd_bot_audio | 1.3.6.1.4.1.5528.30.10.4 | integer | read-only |
The reading of the audio alarm probe on/off. |
netBotz_prd_bot_doorajar | 1.3.6.1.4.1.5528.30.10.5 | integer | read-only |
The reading of the door switch probe open(1) or closed(0). |
netBotz_prd_bot_temp_min | 1.3.6.1.4.1.5528.30.10.6 | integer | read-write |
The temperature probe minimum, from 35 to 120 degrees F, or 1 to 50 degrees C (depends on netBotz-ismetric). |
netBotz_prd_bot_temp_max | 1.3.6.1.4.1.5528.30.10.7 | integer | read-write |
The temperature probe maximum, from 35 to 120 degrees F, or 1 to 50 degrees C (depends on netBotz-ismetric). |
netBotz_prd_bot_humidity_min | 1.3.6.1.4.1.5528.30.10.8 | integer | read-write |
The humidity probe minimum, from 10 to 90 percent. |
netBotz_prd_bot_humidity_max | 1.3.6.1.4.1.5528.30.10.9 | integer | read-write |
The humidity probe maximum, from 10 to 90 percent. |
netBotz_prd_bot_airflow_mins | 1.3.6.1.4.1.5528.30.10.10 | integer | read-write |
Minutes without airflow before alarm set. |
netBotz_prd_bot_audio_secs | 1.3.6.1.4.1.5528.30.10.11 | integer | read-write |
Seconds of alarm audio before alarm set. |
netBotz_prd_bot_temp_enabled | 1.3.6.1.4.1.5528.30.10.12 | integer | read-write |
Temperature probe alarm enabled(1) or disabled(0). |
netBotz_prd_bot_hum_enabled | 1.3.6.1.4.1.5528.30.10.13 | integer | read-write |
Humidity probe alarm enabled(1) or disabled(0). |
netBotz_prd_bot_air_enabled | 1.3.6.1.4.1.5528.30.10.14 | integer | read-write |
Airflow probe alarm enabled(1) or disabled(0). |
netBotz_prd_bot_audio_enabled | 1.3.6.1.4.1.5528.30.10.15 | integer | read-write |
Audio probe alarm enabled(1) or disabled(0). |
netBotz_prd_bot_switch_state | 1.3.6.1.4.1.5528.30.10.16 | integer | read-write |
Switch state setting. The state controls which condition of the door switch indicates an alarm. If set to 0, alarm is set when the switch is closed. If set to 1, alarm is set when the switch is open. |
netBotz_prd_bot_switch_enabled | 1.3.6.1.4.1.5528.30.10.17 | integer | read-write |
Door switch enabled(1) or disabled(0). |
netBotz_prd_bot_audio_level | 1.3.6.1.4.1.5528.30.10.18 | integer | read-write |
Audio level setting. This is the relative audio level, from 0-11, above which an alarm will be sent. |
netBotz_prd_bot_trap_index | 1.3.6.1.4.1.5528.30.10.20 | integer | read-only |
The crawler ID of the last trap. |
netBotz_prd_bot_trap_address | 1.3.6.1.4.1.5528.30.10.21 | ipaddress | read-only |
The IP address of the last trap. |
netBotz_prd_bot_trap_oid | 1.3.6.1.4.1.5528.30.10.22 | object identifier | read-only |
The object id of the last trap. |
netBotz_prd_bot_trap_value | 1.3.6.1.4.1.5528.30.10.23 | integer | read-only |
The value of the last object trap. |
netBotz_prd_bot_trap_date | 1.3.6.1.4.1.5528.30.10.24 | integer | read-only |
The date and time of a specific trap. This field contains the number of seconds elapsed since midnight (00:00:00), January 1, 1970 |
netBotz_prd_bot_refresh | 1.3.6.1.4.1.5528.30.10.26 | integer | read-write |
Rate of web page refresh, in seconds. This must be greater than 5 seconds. |
netBotz_prd_bot_airflow_level | 1.3.6.1.4.1.5528.30.10.27 | integer | read-write |
Airflow alert level. This is the relative level of airflow below which an alarm will be sent. The range is 1-11. Each unit is approximately 40 feet/second or 13 meters/second of airflow velocity. |
netBotz_prd_bot_doorpic_count | 1.3.6.1.4.1.5528.30.10.28 | integer | read-write |
Number of pictures to take when door activated. These pictures will be sent as attachments to the door alert e-mail. The range is from 0 to 5 pictures. |
netBotz_prd_bot_amps1 | 1.3.6.1.4.1.5528.30.10.29 | integer | read-only |
The reading of the first amperage probe, in milliamps. |
netBotz_prd_bot_amps1_enabled | 1.3.6.1.4.1.5528.30.10.30 | integer | read-write |
Amperage[1] probe alarm enabled(1) or disabled(0). |
netBotz_prd_bot_amps1_min | 1.3.6.1.4.1.5528.30.10.31 | integer | read-write |
The amperage[1] probe minimum, from 0 to 30000 milliamps. |
netBotz_prd_bot_amps1_max | 1.3.6.1.4.1.5528.30.10.32 | integer | read-write |
The amperage[1] probe maximum, from 0 to 30000 milliamps. |
netBotz_prd_bot_amps2 | 1.3.6.1.4.1.5528.30.10.34 | integer | read-only |
The reading of the second amperage probe, in milliamps. |
netBotz_prd_bot_amps2_enabled | 1.3.6.1.4.1.5528.30.10.35 | integer | read-write |
Amperage[2] probe alarm enabled(1) or disabled(0). |
netBotz_prd_bot_amps2_min | 1.3.6.1.4.1.5528.30.10.36 | integer | read-write |
The amperage[2] probe minimum, from 0 to 30000 milliamps. |
netBotz_prd_bot_amps2_max | 1.3.6.1.4.1.5528.30.10.37 | integer | read-write |
The amperage[2] probe maximum, from 0 to 30000 milliamps. |
netBotz_prd_bot_amps3 | 1.3.6.1.4.1.5528.30.10.39 | integer | read-only |
The reading of the third amperage probe, in milliamps. |
netBotz_prd_bot_amps3_enabled | 1.3.6.1.4.1.5528.30.10.40 | integer | read-write |
Amperage[3] probe alarm enabled(1) or disabled(0). |
netBotz_prd_bot_amps3_min | 1.3.6.1.4.1.5528.30.10.41 | integer | read-write |
The amperage[3] probe minimum, from 0 to 30000 milliamps. |
netBotz_prd_bot_amps3_max | 1.3.6.1.4.1.5528.30.10.42 | integer | read-write |
The amperage[3] probe maximum, from 0 to 30000 milliamps. |
netBotz_prd_bot_amps_total | 1.3.6.1.4.1.5528.30.10.44 | integer | read-only |
The total of the readings of all amperage probes, in milliamps. |
netBotz_prd_bot_amps_total_enabled | 1.3.6.1.4.1.5528.30.10.45 | integer | read-write |
Total amperage alarm enabled(1) or disabled(0). |
netBotz_prd_bot_amps_total_min | 1.3.6.1.4.1.5528.30.10.46 | integer | read-write |
The total amperage minimum, from 0 to 90000 milliamps. |
netBotz_prd_bot_amps_total_max | 1.3.6.1.4.1.5528.30.10.47 | integer | read-write |
The total amperage maximum, from 0 to 90000 milliamps. |
netBotz_prd_bot_amps_total_support_enabled | 1.3.6.1.4.1.5528.30.10.48 | displaystring | read-write |
Total Amperage Support enabled(Y) or disabled(N). |
netBotz_prd_bot_amps1_uV_per_10mA | 1.3.6.1.4.1.5528.30.10.49 | integer | read-write |
The scaling factor used for the first amperage probe to convert microvolts measured from the Amp Detect into 10s of milliamps of current. Needs to be set based on the type of Amp Detect module installed. |
netBotz_prd_bot_amps2_uV_per_10mA | 1.3.6.1.4.1.5528.30.10.50 | integer | read-write |
The scaling factor used for the second amperage probe to convert microvolts measured from the Amp Detect into 10s of milliamps of current. Needs to be set based on the type of Amp Detect module installed. |
netBotz_prd_bot_amps3_uV_per_mA | 1.3.6.1.4.1.5528.30.10.51 | integer | read-write |
The scaling factor used for the third amperage probe to convert microvolts measured from the Amp Detect into 10s of milliamps of current. Needs to be set based on the type of Amp Detect module installed. |
netBotz_prd_bot_amps1_max_range | 1.3.6.1.4.1.5528.30.10.52 | integer | read-write |
The maximum RMS milliamps measureable by the first Amp Detect. |
netBotz_prd_bot_amps2_max_range | 1.3.6.1.4.1.5528.30.10.53 | integer | read-write |
The maximum RMS milliamps measureable by the second Amp Detect. |
netBotz_prd_bot_amps3_max_range | 1.3.6.1.4.1.5528.30.10.54 | integer | read-write |
The maximum RMS milliamps measureable by the third Amp Detect. |
netBotz_prd_bot_amps4 | 1.3.6.1.4.1.5528.30.10.55 | integer | read-only |
The reading of the fourth amperage probe, in milliamps. |
netBotz_prd_bot_amps4_enabled | 1.3.6.1.4.1.5528.30.10.56 | integer | read-write |
Amperage[4] probe alarm enabled(1) or disabled(0). |
netBotz_prd_bot_amps4_min | 1.3.6.1.4.1.5528.30.10.57 | integer | read-write |
The amperage[4] probe minimum, in milliamps. |
netBotz_prd_bot_amps4_max | 1.3.6.1.4.1.5528.30.10.58 | integer | read-write |
The amperage[4] probe maximum, in milliamps. |
netBotz_prd_bot_amps4_uV_per_10mA | 1.3.6.1.4.1.5528.30.10.60 | integer | read-write |
The scaling factor used for the fourth amperage probe to convert microvolts measured from the Amp Detect into 10s of milliamps of current. Needs to be set based on the type of Amp Detect module installed. |
netBotz_prd_bot_amps4_max_range | 1.3.6.1.4.1.5528.30.10.61 | integer | read-write |
The maximum RMS milliamps measureable by the fourth Amp Detect. |
netBotz_prd_bot_ext_temp1 | 1.3.6.1.4.1.5528.30.10.62 | integer | read-only |
The reading of the external temperature probe on port 1, in degrees F or degrees C (depends on netBotz-ismetric). |
netBotz_prd_bot_ext_temp2 | 1.3.6.1.4.1.5528.30.10.63 | integer | read-only |
The reading of the external temperature probe on port 2, in degrees F or degrees C (depends on netBotz-ismetric). |
netBotz_prd_bot_ext_temp3 | 1.3.6.1.4.1.5528.30.10.64 | integer | read-only |
The reading of the external temperature probe on port 3, in degrees F or degrees C (depends on netBotz-ismetric). |
netBotz_prd_bot_ext_temp1_enabled | 1.3.6.1.4.1.5528.30.10.66 | integer | read-write |
External temperature probe on port 1 alarm enabled(1) or disabled(0). |
netBotz_prd_bot_ext_temp1_min | 1.3.6.1.4.1.5528.30.10.67 | integer | read-write |
The external temperature probe on port 1 probe minimum, in degrees F or degrees C (depends on netBotz-ismetric). |
netBotz_prd_bot_ext_temp1_max | 1.3.6.1.4.1.5528.30.10.68 | integer | read-write |
The external temperature probe on port 1 probe maximum, in degrees F or degrees C (depends on netBotz-ismetric). |
netBotz_prd_bot_ext_temp2_enabled | 1.3.6.1.4.1.5528.30.10.69 | integer | read-write |
External temperature probe on port 2 alarm enabled(1) or disabled(0). |
netBotz_prd_bot_ext_temp2_min | 1.3.6.1.4.1.5528.30.10.70 | integer | read-write |
The external temperature probe on port 2 probe minimum, in degrees F or degrees C (depends on netBotz-ismetric). |
netBotz_prd_bot_ext_temp2_max | 1.3.6.1.4.1.5528.30.10.71 | integer | read-write |
The external temperature probe on port 2 probe maximum, in degrees F or degrees C (depends on netBotz-ismetric). |
netBotz_prd_bot_ext_temp3_enabled | 1.3.6.1.4.1.5528.30.10.72 | integer | read-write |
External temperature probe on port 3 alarm enabled(1) or disabled(0). |
netBotz_prd_bot_ext_temp3_min | 1.3.6.1.4.1.5528.30.10.73 | integer | read-write |
The external temperature probe on port 3 probe minimum, in degrees F or degrees C (depends on netBotz-ismetric). |
netBotz_prd_bot_ext_temp3_max | 1.3.6.1.4.1.5528.30.10.74 | integer | read-write |
The external temperature probe on port 3 probe maximum, in degrees F or degrees C (depends on netBotz-ismetric). |
netBotz_prd_bot_ext_temp1_uV_per_degreeC | 1.3.6.1.4.1.5528.30.10.78 | integer | read-write |
The scaling factor used for the external temperature probe on port 1 to convert microvolts measured from the temperature sensor into degrees C. Needs to be set based on the type of temperature sensor module installed. |
netBotz_prd_bot_ext_temp1_uV_at_0_degreeC | 1.3.6.1.4.1.5528.30.10.79 | integer | read-write |
The offset used for the external temperature probe on port 1 of microvolts measured from the temperature sensor at zero degrees C. Needs to be set based on the type of temperature sensor module installed. |
netBotz_prd_bot_ext_temp1_min_range | 1.3.6.1.4.1.5528.30.10.80 | integer | read-write |
The minimum temperature measureable by the temperature sensor installed on port 1, in tenths of a degree C. Needs to be set based on the type of temperature sensor module installed. |
netBotz_prd_bot_ext_temp1_max_range | 1.3.6.1.4.1.5528.30.10.81 | integer | read-write |
The maximum temperature measureable by the temperature sensor installed on port 1, in tenths of a degree C. Needs to be set based on the type of temperature sensor module installed. |
netBotz_prd_bot_ext_temp2_uV_per_degreeC | 1.3.6.1.4.1.5528.30.10.82 | integer | read-write |
The scaling factor used for the external temperature probe on port 2 to convert microvolts measured from the temperature sensor into degrees C. Needs to be set based on the type of temperature sensor module installed. |
netBotz_prd_bot_ext_temp2_uV_at_0_degreeC | 1.3.6.1.4.1.5528.30.10.83 | integer | read-write |
The offset used for the external temperature probe on port 2 of microvolts measured from the temperature sensor at zero degrees C. Needs to be set based on the type of temperature sensor module installed. |
netBotz_prd_bot_ext_temp2_min_range | 1.3.6.1.4.1.5528.30.10.84 | integer | read-write |
The minimum temperature measureable by the temperature sensor installed on port 2, in tenths of a degree C. Needs to be set based on the type of temperature sensor module installed. |
netBotz_prd_bot_ext_temp2_max_range | 1.3.6.1.4.1.5528.30.10.85 | integer | read-write |
The maximum temperature measureable by the temperature sensor installed on port 2, in tenths of a degree C. Needs to be set based on the type of temperature sensor module installed. |
netBotz_prd_bot_ext_temp3_uV_per_degreeC | 1.3.6.1.4.1.5528.30.10.86 | integer | read-write |
The scaling factor used for the external temperature probe on port 3 to convert microvolts measured from the temperature sensor into degrees C. Needs to be set based on the type of temperature sensor module installed. |
netBotz_prd_bot_ext_temp3_uV_at_0_degreeC | 1.3.6.1.4.1.5528.30.10.87 | integer | read-write |
The offset used for the external temperature probe on port 3 of microvolts measured from the temperature sensor at zero degrees C. Needs to be set based on the type of temperature sensor module installed. |
netBotz_prd_bot_ext_temp3_min_range | 1.3.6.1.4.1.5528.30.10.88 | integer | read-write |
The minimum temperature measureable by the temperature sensor installed on port 3, in tenths of a degree C. Needs to be set based on the type of temperature sensor module installed. |
netBotz_prd_bot_ext_temp3_max_range | 1.3.6.1.4.1.5528.30.10.89 | integer | read-write |
The maximum temperature measureable by the temperature sensor installed on port 3, in tenths of a degree C. Needs to be set based on the type of temperature sensor module installed. |
netBotz_prd_bot_ext_port1_module_id | 1.3.6.1.4.1.5528.30.10.94 | displaystring | read-write |
The module ID of the sensor module installed on port 1. Blank string indicates that no module is installed. |
netBotz_prd_bot_ext_port1_module_type | 1.3.6.1.4.1.5528.30.10.95 | displaystring | read-write |
The type of sensor module installed on port 1. NONE=no module, AMP=AmpDetect module, TEMP=temperature sensor, DRY=dry contact sensor. |
netBotz_prd_bot_ext_port2_module_id | 1.3.6.1.4.1.5528.30.10.96 | displaystring | read-write |
The module ID of the sensor module installed on port 2. Blank string indicates that no module is installed. |
netBotz_prd_bot_ext_port2_module_type | 1.3.6.1.4.1.5528.30.10.97 | displaystring | read-write |
The type of sensor module installed on port 2. NONE=no module, AMP=AmpDetect module, TEMP=temperature sensor, DRY=dry contact sensor. |
netBotz_prd_bot_ext_port3_module_id | 1.3.6.1.4.1.5528.30.10.98 | displaystring | read-write |
The module ID of the sensor module installed on port 3. Blank string indicates that no module is installed. |
netBotz_prd_bot_ext_port3_module_type | 1.3.6.1.4.1.5528.30.10.99 | displaystring | read-write |
The type of sensor module installed on port 3. NONE=no module, AMP=AmpDetect module, TEMP=temperature sensor, DRY=dry contact sensor. |
netBotz_prd_bot_amp1_total_amp_seconds | 1.3.6.1.4.1.5528.30.10.102 | integer | read-only |
The accumulated total of amp-seconds on the AmpDetect on port 1. |
netBotz_prd_bot_amp1_total_amp_seconds_since_time | 1.3.6.1.4.1.5528.30.10.103 | integer | read-write |
The UTC time (seconds since 1/1/1970) of the beginning of the accumulated total of amp-seconds on the AmpDetect on port 1. Writing a value to this attribute resets the accumulated total amp-seconds and sets this time to the current time. |
netBotz_prd_bot_amp2_total_amp_seconds | 1.3.6.1.4.1.5528.30.10.104 | integer | read-only |
The accumulated total of amp-seconds on the AmpDetect on port 2. |
netBotz_prd_bot_amp2_total_amp_seconds_since_time | 1.3.6.1.4.1.5528.30.10.105 | integer | read-write |
The UTC time (seconds since 1/1/1970) of the beginning of the accumulated total of amp-seconds on the AmpDetect on port 2. Writing a value to this attribute resets the accumulated total amp-seconds and sets this time to the current time. |
netBotz_prd_bot_amp3_total_amp_seconds | 1.3.6.1.4.1.5528.30.10.106 | integer | read-only |
The accumulated total of amp-seconds on the AmpDetect on port 3. |
netBotz_prd_bot_amp3_total_amp_seconds_since_time | 1.3.6.1.4.1.5528.30.10.107 | integer | read-write |
The UTC time (seconds since 1/1/1970) of the beginning of the accumulated total of amp-seconds on the AmpDetect on port 3. Writing a value to this attribute resets the accumulated total amp-seconds and sets this time to the current time. |
netBotz_prd_bot_amp4_total_amp_seconds | 1.3.6.1.4.1.5528.30.10.108 | integer | read-only |
The accumulated total of amp-seconds on the AmpDetect on port 4. |
netBotz_prd_bot_amp4_total_amp_seconds_since_time | 1.3.6.1.4.1.5528.30.10.109 | integer | read-write |
The UTC time (seconds since 1/1/1970) of the beginning of the accumulated total of amp-seconds on the AmpDetect on port 4. Writing a value to this attribute resets the accumulated total amp-seconds and sets this time to the current time. |
netBotz_prd_bot_amptotal_total_amp_seconds | 1.3.6.1.4.1.5528.30.10.110 | integer | read-only |
The accumulated total of amp-seconds on the total of all AmpDetects. |
netBotz_prd_bot_amptotal_total_amp_seconds_since_time | 1.3.6.1.4.1.5528.30.10.111 | integer | read-write |
The UTC time (seconds since 1/1/1970) of the beginning of the accumulated total of amp-seconds for all AmpDetects. Writing a value to this attribute resets the accumulated total amp-seconds and sets this time to the current time. |
netBotz_prd_bot_ext_dry1 | 1.3.6.1.4.1.5528.30.10.112 | integer | read-only |
The current value of the external dry contact sensor on Ext1: 0=Open, 1=Closed, -1=N/A |
netBotz_prd_bot_ext_dry2 | 1.3.6.1.4.1.5528.30.10.113 | integer | read-only |
The current value of the external dry contact sensor on Ext2: 0=Open, 1=Closed, -1=N/A |
netBotz_prd_bot_ext_dry3 | 1.3.6.1.4.1.5528.30.10.114 | integer | read-only |
The current value of the external dry contact sensor on Ext3: 0=Open, 1=Closed, -1=N/A |
netBotz_prd_bot_ext_dry4 | 1.3.6.1.4.1.5528.30.10.115 | integer | read-only |
The current value of the external dry contact sensor on Ext4: 0=Open, 1=Closed, -1=N/A |
netBotz_prd_bot_ext_dry1_alarm_value | 1.3.6.1.4.1.5528.30.10.116 | integer | read-write |
The value to generate alarms on for the external dry contact sensor on Ext1: 0=Open, 1=Closed |
netBotz_prd_bot_ext_dry1_enabled | 1.3.6.1.4.1.5528.30.10.117 | integer | read-write |
External dry contact sensor on Ext1 alarm enabled(1) or disabled(0). |
netBotz_prd_bot_ext_dry2_alarm_value | 1.3.6.1.4.1.5528.30.10.118 | integer | read-write |
The value to generate alarms on for the external dry contact sensor on Ext2: 0=Open, 1=Closed |
netBotz_prd_bot_ext_dry2_enabled | 1.3.6.1.4.1.5528.30.10.119 | integer | read-write |
External dry contact sensor on Ext2 alarm enabled(1) or disabled(0). |
netBotz_prd_bot_ext_dry3_alarm_value | 1.3.6.1.4.1.5528.30.10.120 | integer | read-write |
The value to generate alarms on for the external dry contact sensor on Ext3: 0=Open, 1=Closed |
netBotz_prd_bot_ext_dry3_enabled | 1.3.6.1.4.1.5528.30.10.121 | integer | read-write |
External dry contact sensor on Ext3 alarm enabled(1) or disabled(0). |
netBotz_prd_bot_ext_dry4_alarm_value | 1.3.6.1.4.1.5528.30.10.122 | integer | read-write |
The value to generate alarms on for the external dry contact sensor on Ext4: 0=Open, 1=Closed |
netBotz_prd_bot_ext_dry4_enabled | 1.3.6.1.4.1.5528.30.10.123 | integer | read-write |
External dry contact sensor on Ext4 alarm enabled(1) or disabled(0). |
netBotz_prd_bot_ext_dry1_label | 1.3.6.1.4.1.5528.30.10.124 | displaystring | read-write |
The sensor name/label for the dry contact sensor on Ext1 |
netBotz_prd_bot_ext_dry1_open_label | 1.3.6.1.4.1.5528.30.10.125 | displaystring | read-write |
The sensor name/label for the open(0) state for the dry contact sensor on Ext1 |
netBotz_prd_bot_ext_dry1_closed_label | 1.3.6.1.4.1.5528.30.10.126 | displaystring | read-write |
The sensor name/label for the closed(0) state for the dry contact sensor on Ext1 |
netBotz_prd_bot_ext_dry1_open_to_close_millis | 1.3.6.1.4.1.5528.30.10.127 | integer | read-write |
The minimum number of milliseconds that the dry contact sensor on Ext1 must read closed before the state is changed from open to closed. |
netBotz_prd_bot_ext_dry1_close_to_open_millis | 1.3.6.1.4.1.5528.30.10.128 | integer | read-write |
The minimum number of milliseconds that the dry contact sensor on Ext1 must read openbefore the state is changed from closed to open. |
netBotz_prd_bot_ext_dry1_response | 1.3.6.1.4.1.5528.30.10.129 | displaystring | read-write |
The type of alert response for the dry contact sensor on Ext1: ALERT=e-mail with no pictures, CAMERA=e-mail with pictures from camera. |
netBotz_prd_bot_ext_dry2_label | 1.3.6.1.4.1.5528.30.10.130 | displaystring | read-write |
The sensor name/label for the dry contact sensor on Ext2 |
netBotz_prd_bot_ext_dry2_open_label | 1.3.6.1.4.1.5528.30.10.131 | displaystring | read-write |
The sensor name/label for the open(0) state for the dry contact sensor on Ext2 |
netBotz_prd_bot_ext_dry2_closed_label | 1.3.6.1.4.1.5528.30.10.132 | displaystring | read-write |
The sensor name/label for the closed(0) state for the dry contact sensor on Ext2 |
netBotz_prd_bot_ext_dry2_open_to_close_millis | 1.3.6.1.4.1.5528.30.10.133 | integer | read-write |
The minimum number of milliseconds that the dry contact sensor on Ext2 must read closed before the state is changed from open to closed. |
netBotz_prd_bot_ext_dry2_close_to_open_millis | 1.3.6.1.4.1.5528.30.10.134 | integer | read-write |
The minimum number of milliseconds that the dry contact sensor on Ext2 must read openbefore the state is changed from closed to open. |
netBotz_prd_bot_ext_dry2_response | 1.3.6.1.4.1.5528.30.10.135 | displaystring | read-write |
The type of alert response for the dry contact sensor on Ext2: ALERT=e-mail with no pictures, CAMERA=e-mail with pictures from camera. |
netBotz_prd_bot_ext_dry3_label | 1.3.6.1.4.1.5528.30.10.136 | displaystring | read-write |
The sensor name/label for the dry contact sensor on Ext3 |
netBotz_prd_bot_ext_dry3_open_label | 1.3.6.1.4.1.5528.30.10.137 | displaystring | read-write |
The sensor name/label for the open(0) state for the dry contact sensor on Ext3 |
netBotz_prd_bot_ext_dry3_closed_label | 1.3.6.1.4.1.5528.30.10.138 | displaystring | read-write |
The sensor name/label for the closed(0) state for the dry contact sensor on Ext3 |
netBotz_prd_bot_ext_dry3_open_to_close_millis | 1.3.6.1.4.1.5528.30.10.139 | integer | read-write |
The minimum number of milliseconds that the dry contact sensor on Ext3 must read closed before the state is changed from open to closed. |
netBotz_prd_bot_ext_dry3_close_to_open_millis | 1.3.6.1.4.1.5528.30.10.140 | integer | read-write |
The minimum number of milliseconds that the dry contact sensor on Ext3 must read openbefore the state is changed from closed to open. |
netBotz_prd_bot_ext_dry3_response | 1.3.6.1.4.1.5528.30.10.141 | displaystring | read-write |
The type of alert response for the dry contact sensor on Ext3: ALERT=e-mail with no pictures, CAMERA=e-mail with pictures from camera. |
netBotz_prd_bot_cam_motion | 1.3.6.1.4.1.5528.30.10.148 | integer | read-only |
The current motion reading for the camera motion sensor (0=none, 1=motion detected) |
netBotz_prd_bot_cam_motion_enabled | 1.3.6.1.4.1.5528.30.10.149 | integer | read-write |
Camera motion sensor alarm enabled(1) or disabled(0). |
netBotz_prd_bot_cam_motion_sensitivity | 1.3.6.1.4.1.5528.30.10.150 | integer | read-write |
Camera motion sensor sensitivity: 1=max, 15=min, 0=disabled. |
netBotz_prd_bot_cam_motion_delay | 1.3.6.1.4.1.5528.30.10.151 | integer | read-write |
Camera motion sensor delay. This is the minimum number of milliseconds of detected motion required before the alarm is triggered. |
netBotz_prd_bot_camera_event_autocycle | 1.3.6.1.4.1.5528.30.10.152 | integer | read-write |
Enables (1) or disables (0) the option to have the camera-based responses to alarm conditions automatically cycle as long as the condition persists. |
netBotz_prd_bot_num_pix_before_alarm | 1.3.6.1.4.1.5528.30.10.153 | integer | read-write |
Controls the number of pictures to be captured before any triggered alarm. |
netBotz_prd_bot_delay_before_event_pix | 1.3.6.1.4.1.5528.30.10.154 | integer | read-write |
Controls the number of milliseconds before the first picture is captured after any triggered alarm. |
netBotz_prd_bot_delay_between_event_pix | 1.3.6.1.4.1.5528.30.10.155 | integer | read-write |
Controls the number of milliseconds between pictures captured after any triggered alarm. |
netBotz_prd_bot_cam_motion_area_of_motion | 1.3.6.1.4.1.5528.30.10.156 | integer | read-write |
Camera motion sensor area of motion: 1=max, 15=min, 0=disabled. |
netBotz_prd_bot_cam_pix_for_duration_of_alerts | 1.3.6.1.4.1.5528.30.10.157 | integer | read-write |
Camera images gathered for duration of camera related alert: 0=no, 1=yes. |
netBotz_prd_bot_camera_enabled | 1.3.6.1.4.1.5528.30.10.158 | integer | read-write |
Controls whether the camera is enabled or not: 0=no, 1=yes. Changing this will reboot the appliance. |
netBotz_prd_bot_camera_is_flipped | 1.3.6.1.4.1.5528.30.10.159 | integer | read-write |
Controls whether the camera image is flipped 180 degress or not: 0=no, 1=yes. Changing this will reboot the appliance. |
netBotz_prd_bot_camera_brightness | 1.3.6.1.4.1.5528.30.10.160 | integer | read-write |
Sets the brightness on the camera, from 20 to 180 (20 is low, 180 is high). |
netBotz_prd_crawlers | 1.3.6.1.4.1.5528.30.20 | |||
netbotz_crawlers | 1.3.6.1.4.1.5528.30.20.5528 | |||
netBotz_prd_crl_mib2 | 1.3.6.1.4.1.5528.30.20.5528.1 | |||
netBotz_prd_crl_mib2_ping | 1.3.6.1.4.1.5528.30.20.5528.1.3 | integer | read-only |
NetBotz device ping. This object indicates the status of a ping on a device monitored by a NetBotz device. |
netBotz_prd_crl_mib2_uptime | 1.3.6.1.4.1.5528.30.20.5528.1.8 | timeticks | read-only |
The uptime of a device monitored by a NetBotz device. |
netBotz_prd_crl_mib2_snmpstatus | 1.3.6.1.4.1.5528.30.20.5528.1.9 | displaystring | read-only |
The SNMP status of a device monitored by a NetBotz device. |
netBotz_prd_crl_ping_offline_trap | 1.3.6.1.4.1.5528.30.20.5528.1.30.4 |
NetBotz Ping Trap. This trap indicates that replies to a set of pings were not received from a monitored IP address. |
||
netBotz_prd_crl_ping_online_trap | 1.3.6.1.4.1.5528.30.20.5528.1.30.5 |
NetBotz Ping Trap. This trap indicates that replies to a set of pings were received from a monitored IP address after a period when no replies had been received. |
||
netBotz_prd_crl_uptime_online_trap | 1.3.6.1.4.1.5528.30.20.5528.1.80.5 |
NetBotz Uptime Trap. This trap indicates that a device restart has been detected due to the uptime of the device being reported as less than the previously reported reading. |
||
netBotz_prd_crl_snmp_offline_trap | 1.3.6.1.4.1.5528.30.20.5528.1.90.4 |
NetBotz SNMP Offline Trap. This trap indicates that an SNMP request was not possible on an IP address. |
||
netBotz_prd_crl_snmp_online_trap | 1.3.6.1.4.1.5528.30.20.5528.1.90.5 |
NetBotz SNMP Online Trap. This trap indicates that an SNMP request succeeded on an IP address where it had previously failed. |
||
netBotz_prd_crl_mib2if | 1.3.6.1.4.1.5528.30.20.5528.2 | |||
netBotz_prd_crl_mib2if_opstatus | 1.3.6.1.4.1.5528.30.20.5528.2.6 | integer | read-only |
The operational status of a device monitored by a NetBotz device. |
netBotz_prd_crl_opstatus_mismatch_trap | 1.3.6.1.4.1.5528.30.20.5528.2.60.1 |
NetBotz Interface Status Mismatch Trap. This trap indicates that the operational status of a device interface does not match the administrative status. |
||
netBotz_prd_crl_opstatus_match_trap | 1.3.6.1.4.1.5528.30.20.5528.2.60.2 |
NetBotz Interface Status Match Trap. This trap indicates that the operational status of a device interface now matches the administrative status. This trap indicates a transition from a state in which the administrative and operational status did not match. |
||
netBotz_prd_crl_opstatus_offline_trap | 1.3.6.1.4.1.5528.30.20.5528.2.60.4 |
NetBotz Interface Offline Trap. This trap indicates that an interface on a device did not respond to an SNMP query on the ifAdminStatus or ifOperStatus objects. |
||
netBotz_prd_crltrap | 1.3.6.1.4.1.5528.30.21 | |||
netBotz_prd_crl_trap_index | 1.3.6.1.4.1.5528.30.21.20 | integer | read-only |
The ID of the crawler which sent the last trap. |
netBotz_prd_crl_trap_address | 1.3.6.1.4.1.5528.30.21.21 | ipaddress | read-only |
The IP address of the last trap. |
netBotz_prd_crl_trap_oid | 1.3.6.1.4.1.5528.30.21.22 | object identifier | read-only |
The object id of the attribute on the target device which is the concern of the last trap. |
netBotz_prd_crl_trap_botoid | 1.3.6.1.4.1.5528.30.21.23 | object identifier | read-only |
The object id of the attribute on the NetBotz device which is the concern of the last trap. |
netBotz_prd_crl_trap_value | 1.3.6.1.4.1.5528.30.21.24 | integer | read-only |
The value of the attribute associated with the last trap. |
netBotz_prd_crl_trap_date | 1.3.6.1.4.1.5528.30.21.25 | integer | read-only |
The date and time of a specific trap. This field contains the number of seconds elapsed since midnight (00:00:00), January 1, 1970 |
netBotz_prd_crl_trap_attrib | 1.3.6.1.4.1.5528.30.21.26 | integer | read-only |
The identification number of the attribute in error |
netBotz_prd_crl_trap_desc | 1.3.6.1.4.1.5528.30.21.27 | displaystring | read-only |
Description or name of the attribute in error |
netBotz_prd_bot_traps | 1.3.6.1.4.1.5528.30.100 | |||
netBotz_prd_bot_low_trap | 1.3.6.1.4.1.5528.30.100.1 |
NetBotz Low Trap. This trap indicates that a lower limit has been exceeded. |
||
netBotz_prd_bot_temperature_traps | 1.3.6.1.4.1.5528.30.100.1 | |||
netBotz_prd_bot_humidity_traps | 1.3.6.1.4.1.5528.30.100.2 | |||
netBotz_prd_bot_high_trap | 1.3.6.1.4.1.5528.30.100.2 |
NetBotz High Trap. This trap indicates that an upper limit has been exceeded. |
||
netBotz_prd_bot_airflow_traps | 1.3.6.1.4.1.5528.30.100.3 | |||
netBotz_prd_bot_trap_clear | 1.3.6.1.4.1.5528.30.100.3 |
NetBotz Cleared Trap. The trap has been cleared because the value has returned to acceptable limits. |
||
netBotz_prd_bot_audio_traps | 1.3.6.1.4.1.5528.30.100.4 | |||
netBotz_prd_bot_offline_trap | 1.3.6.1.4.1.5528.30.100.4 |
NetBotz Device Offline Trap. This trap indicates that a device or function has been determined to be offline. |
||
netBotz_prd_bot_door_traps | 1.3.6.1.4.1.5528.30.100.5 | |||
netBotz_prd_bot_online_trap | 1.3.6.1.4.1.5528.30.100.5 |
NetBotz Device Online Trap. This trap indicates that a device or function has been determined to be online. |
||
netBotz_prd_bot_amp1_traps | 1.3.6.1.4.1.5528.30.100.6 | |||
netBotz_prd_bot_amp2_traps | 1.3.6.1.4.1.5528.30.100.7 | |||
netBotz_prd_bot_amp3_traps | 1.3.6.1.4.1.5528.30.100.8 | |||
netBotz_prd_bot_amp4_traps | 1.3.6.1.4.1.5528.30.100.9 | |||
netBotz_prd_bot_amp_total_traps | 1.3.6.1.4.1.5528.30.100.10 | |||
netBotz_prd_bot_temperature_low_trap | 1.3.6.1.4.1.5528.30.100.10.1 |
NetBotz Temperature Low Trap. This trap indicates that the lower limit for temperature has been exceeded. |
||
netBotz_prd_bot_temperature_high_trap | 1.3.6.1.4.1.5528.30.100.10.2 |
NetBotz Temperature High Trap. This trap indicates that the upper limit for temperature has been exceeded. |
||
netBotz_prd_bot_temperature_trap_clear | 1.3.6.1.4.1.5528.30.100.10.3 |
NetBotz Temperature Cleared Trap. The trap has been cleared because the temperature value has returned to acceptable limits. |
||
netBotz_prd_bot_ext_temp1_traps | 1.3.6.1.4.1.5528.30.100.11 | |||
netBotz_prd_bot_ext_temp2_traps | 1.3.6.1.4.1.5528.30.100.12 | |||
netBotz_prd_bot_ext_temp3_traps | 1.3.6.1.4.1.5528.30.100.13 | |||
netBotz_prd_bot_ext_temp4_traps | 1.3.6.1.4.1.5528.30.100.14 | |||
netBotz_prd_bot_ext_dry1_traps | 1.3.6.1.4.1.5528.30.100.15 | |||
netBotz_prd_bot_ext_dry2_traps | 1.3.6.1.4.1.5528.30.100.16 | |||
netBotz_prd_bot_ext_dry3_traps | 1.3.6.1.4.1.5528.30.100.17 | |||
netBotz_prd_bot_ext_dry4_traps | 1.3.6.1.4.1.5528.30.100.18 | |||
netBotz_prd_bot_amp5_traps | 1.3.6.1.4.1.5528.30.100.19 | |||
netBotz_prd_bot_amp6_traps | 1.3.6.1.4.1.5528.30.100.20 | |||
netBotz_prd_bot_humidity_low_trap | 1.3.6.1.4.1.5528.30.100.20.1 |
NetBotz Humidity Low Trap. This trap indicates that the lower limit for humidity has been exceeded. |
||
netBotz_prd_bot_humidity_high_trap | 1.3.6.1.4.1.5528.30.100.20.2 |
NetBotz Humidity High Trap. This trap indicates that the upper limit for humidity has been exceeded. |
||
netBotz_prd_bot_humidity_trap_clear | 1.3.6.1.4.1.5528.30.100.20.3 |
NetBotz Humidity Cleared Trap. The trap has been cleared because the humidity value has returned to acceptable limits. |
||
netBotz_prd_bot_amp7_traps | 1.3.6.1.4.1.5528.30.100.21 | |||
netBotz_prd_bot_ext_temp5_traps | 1.3.6.1.4.1.5528.30.100.22 | |||
netBotz_prd_bot_ext_temp6_traps | 1.3.6.1.4.1.5528.30.100.23 | |||
netBotz_prd_bot_ext_temp7_traps | 1.3.6.1.4.1.5528.30.100.24 | |||
netBotz_prd_bot_ext_dry5_traps | 1.3.6.1.4.1.5528.30.100.25 | |||
netBotz_prd_bot_ext_dry6_traps | 1.3.6.1.4.1.5528.30.100.26 | |||
netBotz_prd_bot_ext_dry7_traps | 1.3.6.1.4.1.5528.30.100.27 | |||
netBotz_prd_bot_camera_motion_traps | 1.3.6.1.4.1.5528.30.100.28 | |||
netBotz_prd_bot_ext_humi1_traps | 1.3.6.1.4.1.5528.30.100.29 | |||
netBotz_prd_bot_ext_humi2_traps | 1.3.6.1.4.1.5528.30.100.30 | |||
netBotz_prd_bot_airflow_low_trap | 1.3.6.1.4.1.5528.30.100.30.1 |
NetBotz Airflow Low Trap. This trap indicates that the lower limit for airflow has been exceeded. |
||
netBotz_prd_bot_airflow_trap_clear | 1.3.6.1.4.1.5528.30.100.30.3 |
NetBotz Airflow Cleared Trap. The trap has been cleared because the airflow value has returned to acceptable limits. |
||
netBotz_prd_bot_ext_humi3_traps | 1.3.6.1.4.1.5528.30.100.31 | |||
netBotz_prd_bot_ext_humi4_traps | 1.3.6.1.4.1.5528.30.100.32 | |||
netBotz_prd_bot_ext_humi5_traps | 1.3.6.1.4.1.5528.30.100.33 | |||
netBotz_prd_bot_ext_humi6_traps | 1.3.6.1.4.1.5528.30.100.34 | |||
netBotz_prd_bot_ext_humi7_traps | 1.3.6.1.4.1.5528.30.100.35 | |||
netBotz_prd_bot_audio_high_trap | 1.3.6.1.4.1.5528.30.100.40.2 |
NetBotz Audio High Trap. This trap indicates that the upper limit for audio has been exceeded. |
||
netBotz_prd_bot_audio_trap_clear | 1.3.6.1.4.1.5528.30.100.40.3 |
NetBotz Audio Cleared Trap. The trap has been cleared because the audio value has returned to acceptable limits. |
||
netBotz_prd_bot_door_trap_tripped | 1.3.6.1.4.1.5528.30.100.50.2 |
NetBotz Door Sensor Tripped Trap. This trap indicates that the door sensor has been triggered (i.e. opened, if the thresdhold has been set to trip on open, closed if otherwise). |
||
netBotz_prd_bot_door_trap_clear | 1.3.6.1.4.1.5528.30.100.50.3 |
NetBotz Door Cleared Trap. The trap has been cleared because the door sensor has returned to normal (i.e. been closed, if the threshold has been set to trip on open). |
||
netBotz_prd_bot_amp1_low_trap | 1.3.6.1.4.1.5528.30.100.60.1 |
NetBotz Amp1 Low Trap. This trap indicates that the lower limit for the first amp detect has been exceeded. |
||
netBotz_prd_bot_amp1_high_trap | 1.3.6.1.4.1.5528.30.100.60.2 |
NetBotz Amp1 High Trap. This trap indicates that the upper limit for the first amp detect has been exceeded. |
||
netBotz_prd_bot_amp1_trap_clear | 1.3.6.1.4.1.5528.30.100.60.3 |
NetBotz Amp1 Cleared Trap. The trap has been cleared because the first amp detect value has returned to acceptable limits. |
||
netBotz_prd_bot_amp1_sensor_unplugged | 1.3.6.1.4.1.5528.30.100.60.6 |
NetBotz Amp 1 Sensor Unplugged Trap. The sensor for the first AmpDetect is unplugged or malfunctioning. |
||
netBotz_prd_bot_amp1_sensor_replugged | 1.3.6.1.4.1.5528.30.100.60.7 |
NetBotz Amp 1 Sensor Replugged Trap. The sensor for the first AmpDetect was unplugged, but has been reconnected. |
||
netBotz_prd_bot_amp2_low_trap | 1.3.6.1.4.1.5528.30.100.70.1 |
NetBotz Amp2 Low Trap. This trap indicates that the lower limit for the second amp detect has been exceeded. |
||
netBotz_prd_bot_amp2_high_trap | 1.3.6.1.4.1.5528.30.100.70.2 |
NetBotz Amp2 High Trap. This trap indicates that the upper limit for the second amp detect has been exceeded. |
||
netBotz_prd_bot_amp2_trap_clear | 1.3.6.1.4.1.5528.30.100.70.3 |
NetBotz Amp2 Cleared Trap. The trap has been cleared because the second amp detect value has returned to acceptable limits. |
||
netBotz_prd_bot_amp2_sensor_unplugged | 1.3.6.1.4.1.5528.30.100.70.6 |
NetBotz Amp 2 Sensor Unplugged Trap. The sensor for the second AmpDetect is unplugged or malfunctioning. |
||
netBotz_prd_bot_amp2_sensor_replugged | 1.3.6.1.4.1.5528.30.100.70.7 |
NetBotz Amp 2 Sensor Replugged Trap. The sensor for the second AmpDetect was unplugged, but has been reconnected. |
||
netBotz_prd_bot_amp3_low_trap | 1.3.6.1.4.1.5528.30.100.80.1 |
NetBotz Amp3 Low Trap. This trap indicates that the lower limit for the third amp detect has been exceeded. |
||
netBotz_prd_bot_amp3_high_trap | 1.3.6.1.4.1.5528.30.100.80.2 |
NetBotz Amp3 High Trap. This trap indicates that the upper limit for the third amp detect has been exceeded. |
||
netBotz_prd_bot_amp3_trap_clear | 1.3.6.1.4.1.5528.30.100.80.3 |
NetBotz Amp3 Cleared Trap. The trap has been cleared because the third amp detect value has returned to acceptable limits. |
||
netBotz_prd_bot_amp3_sensor_unplugged | 1.3.6.1.4.1.5528.30.100.80.6 |
NetBotz Amp 3 Sensor Unplugged Trap. The sensor for the third AmpDetect is unplugged or malfunctioning. |
||
netBotz_prd_bot_amp3_sensor_replugged | 1.3.6.1.4.1.5528.30.100.80.7 |
NetBotz Amp 3 Sensor Replugged Trap. The sensor for the third AmpDetect was unplugged, but has been reconnected. |
||
netBotz_prd_bot_amp4_low_trap | 1.3.6.1.4.1.5528.30.100.90.1 |
NetBotz Amp4 Low Trap. This trap indicates that the lower limit for the fourth amp detect has been exceeded. |
||
netBotz_prd_bot_amp4_high_trap | 1.3.6.1.4.1.5528.30.100.90.2 |
NetBotz Amp4 High Trap. This trap indicates that the upper limit for the fourth amp detect has been exceeded. |
||
netBotz_prd_bot_amp4_trap_clear | 1.3.6.1.4.1.5528.30.100.90.3 |
NetBotz Amp4 Cleared Trap. The trap has been cleared because the fourth amp detect value has returned to acceptable limits. |
||
netBotz_prd_bot_amp4_sensor_unplugged | 1.3.6.1.4.1.5528.30.100.90.6 |
NetBotz Amp 4 Sensor Unplugged Trap. The sensor for the fourth AmpDetect is unplugged or malfunctioning. |
||
netBotz_prd_bot_amp4_sensor_replugged | 1.3.6.1.4.1.5528.30.100.90.7 |
NetBotz Amp 4 Sensor Replugged Trap. The sensor for the fourth AmpDetect was unplugged, but has been reconnected. |
||
netBotz_prd_bot_amp_total_low_trap | 1.3.6.1.4.1.5528.30.100.100.1 |
NetBotz Total Amps Low Trap. This trap indicates that the lower limit for the total amperage has been exceeded. |
||
netBotz_prd_bot_amp_total_high_trap | 1.3.6.1.4.1.5528.30.100.100.2 |
NetBotz Total Amps High Trap. This trap indicates that the upper limit for the total amperage has been exceeded. |
||
netBotz_prd_bot_amp_total_trap_clear | 1.3.6.1.4.1.5528.30.100.100.3 |
NetBotz Total Amps Cleared Trap. The trap has been cleared because the total amperage value has returned to acceptable limits. |
||
netBotz_prd_bot_ext_temp1_low_trap | 1.3.6.1.4.1.5528.30.100.110.1 |
NetBotz External Temperature 1 Low Trap. This trap indicates that the lower limit for external temperature probe on port 1 has been exceeded. |
||
netBotz_prd_bot_ext_temp1_high_trap | 1.3.6.1.4.1.5528.30.100.110.2 |
NetBotz External Temperature 1 High Trap. This trap indicates that the upper limit for external temperature probe on port 1 has been exceeded. |
||
netBotz_prd_bot_ext_temp1_trap_clear | 1.3.6.1.4.1.5528.30.100.110.3 |
NetBotz External Temperature 1 Cleared Trap. The trap has been cleared because the temperature value for the temperature probe on port 1 has returned to acceptable limits. |
||
netBotz_prd_bot_ext_temp1_sensor_unplugged | 1.3.6.1.4.1.5528.30.100.110.6 |
NetBotz External Temperature 1 Sensor Unplugged Trap. The sensor is unplugged or malfunctioning. |
||
netBotz_prd_bot_ext_temp1_sensor_replugged | 1.3.6.1.4.1.5528.30.100.110.7 |
NetBotz External Temperature 1 Sensor Replugged Trap. The sensor was unplugged, but has been reconnected. |
||
netBotz_prd_bot_ext_temp2_low_trap | 1.3.6.1.4.1.5528.30.100.120.1 |
NetBotz External Temperature 2 Low Trap. This trap indicates that the lower limit for external temperature probe on port 2 has been exceeded. |
||
netBotz_prd_bot_ext_temp2_high_trap | 1.3.6.1.4.1.5528.30.100.120.2 |
NetBotz External Temperature 2 High Trap. This trap indicates that the upper limit for external temperature probe on port 2 has been exceeded. |
||
netBotz_prd_bot_ext_temp2_trap_clear | 1.3.6.1.4.1.5528.30.100.120.3 |
NetBotz External Temperature 2 Cleared Trap. The trap has been cleared because the temperature value for the temperature probe on port 2 has returned to acceptable limits. |
||
netBotz_prd_bot_ext_temp2_sensor_unplugged | 1.3.6.1.4.1.5528.30.100.120.6 |
NetBotz External Temperature 2 Sensor Unplugged Trap. The sensor is unplugged or malfunctioning. |
||
netBotz_prd_bot_ext_temp2_sensor_replugged | 1.3.6.1.4.1.5528.30.100.120.7 |
NetBotz External Temperature 2 Sensor Replugged Trap. The sensor was unplugged, but has been reconnected. |
||
netBotz_prd_bot_ext_temp3_low_trap | 1.3.6.1.4.1.5528.30.100.130.1 |
NetBotz External Temperature 3 Low Trap. This trap indicates that the lower limit for external temperature probe on port 3 has been exceeded. |
||
netBotz_prd_bot_ext_temp3_high_trap | 1.3.6.1.4.1.5528.30.100.130.2 |
NetBotz External Temperature 3 High Trap. This trap indicates that the upper limit for external temperature probe on port 3 has been exceeded. |
||
netBotz_prd_bot_ext_temp3_trap_clear | 1.3.6.1.4.1.5528.30.100.130.3 |
NetBotz External Temperature 3 Cleared Trap. The trap has been cleared because the temperature value for the temperature probe on port 3 has returned to acceptable limits. |
||
netBotz_prd_bot_ext_temp3_sensor_unplugged | 1.3.6.1.4.1.5528.30.100.130.6 |
NetBotz External Temperature 3 Sensor Unplugged Trap. The sensor is unplugged or malfunctioning. |
||
netBotz_prd_bot_ext_temp3_sensor_replugged | 1.3.6.1.4.1.5528.30.100.130.7 |
NetBotz External Temperature 3 Sensor Replugged Trap. The sensor was unplugged, but has been reconnected. |
||
netBotz_prd_bot_ext_temp4_low_trap | 1.3.6.1.4.1.5528.30.100.140.1 |
NetBotz External Temperature 4 Low Trap. This trap indicates that the lower limit for external temperature probe on port 4 has been exceeded. |
||
netBotz_prd_bot_ext_temp4_high_trap | 1.3.6.1.4.1.5528.30.100.140.2 |
NetBotz External Temperature 4 High Trap. This trap indicates that the upper limit for external temperature probe on port 4 has been exceeded. |
||
netBotz_prd_bot_ext_temp4_trap_clear | 1.3.6.1.4.1.5528.30.100.140.3 |
NetBotz External Temperature 4 Cleared Trap. The trap has been cleared because the temperature value for the temperature probe on port 4 has returned to acceptable limits. |
||
netBotz_prd_bot_ext_temp4_sensor_unplugged | 1.3.6.1.4.1.5528.30.100.140.6 |
NetBotz External Temperature 4 Sensor Unplugged Trap. The sensor is unplugged or malfunctioning. |
||
netBotz_prd_bot_ext_temp4_sensor_replugged | 1.3.6.1.4.1.5528.30.100.140.7 |
NetBotz External Temperature 4 Sensor Replugged Trap. The sensor was unplugged, but has been reconnected. |
||
netBotz_prd_bot_ext_dry1_triggered_trap | 1.3.6.1.4.1.5528.30.100.150.2 |
NetBotz External Dry Contact 1 Triggered Trap. This trap indicates that the state of the dry contact sensor on Ext1 matches the alarm value. |
||
netBotz_prd_bot_ext_dry1_trap_clear | 1.3.6.1.4.1.5528.30.100.150.3 |
NetBotz External Dry Contact 1 Cleared Trap. The trap has been cleared because the state of the dry contact sensor on Ext1 no longer matches the alarm value. |
||
netBotz_prd_bot_ext_dry2_triggered_trap | 1.3.6.1.4.1.5528.30.100.160.2 |
NetBotz External Dry Contact 2 Triggered Trap. This trap indicates that the state of the dry contact sensor on Ext2 matches the alarm value. |
||
netBotz_prd_bot_ext_dry2_trap_clear | 1.3.6.1.4.1.5528.30.100.160.3 |
NetBotz External Dry Contact 2 Cleared Trap. The trap has been cleared because the state of the dry contact sensor on Ext2 no longer matches the alarm value. |
||
netBotz_prd_bot_ext_dry3_triggered_trap | 1.3.6.1.4.1.5528.30.100.170.2 |
NetBotz External Dry Contact 3 Triggered Trap. This trap indicates that the state of the dry contact sensor on Ext3 matches the alarm value. |
||
netBotz_prd_bot_ext_dry3_trap_clear | 1.3.6.1.4.1.5528.30.100.170.3 |
NetBotz External Dry Contact 3 Cleared Trap. The trap has been cleared because the state of the dry contact sensor on Ext3 no longer matches the alarm value. |
||
netBotz_prd_bot_ext_dry4_triggered_trap | 1.3.6.1.4.1.5528.30.100.180.2 |
NetBotz External Dry Contact 4 Triggered Trap. This trap indicates that the state of the dry contact sensor on Ext4 matches the alarm value. |
||
netBotz_prd_bot_ext_dry4_trap_clear | 1.3.6.1.4.1.5528.30.100.180.3 |
NetBotz External Dry Contact 4 Cleared Trap. The trap has been cleared because the state of the dry contact sensor on Ext4 no longer matches the alarm value. |
||
netBotz_prd_bot_amp5_low_trap | 1.3.6.1.4.1.5528.30.100.190.1 |
NetBotz Amp 5 Low Trap. This trap indicates that the lower limit for the fifth amp detect has been exceeded. |
||
netBotz_prd_bot_amp5_high_trap | 1.3.6.1.4.1.5528.30.100.190.2 |
NetBotz Amp 5 High Trap. This trap indicates that the upper limit for the fifth amp detect has been exceeded. |
||
netBotz_prd_bot_amp5_trap_clear | 1.3.6.1.4.1.5528.30.100.190.3 |
NetBotz Amp 5 Cleared Trap. The trap has been cleared because the fifth amp detect value has returned to acceptable limits. |
||
netBotz_prd_bot_amp5_sensor_unplugged | 1.3.6.1.4.1.5528.30.100.190.6 |
NetBotz Amp 5 Sensor Unplugged Trap. The sensor for the fifth AmpDetect is unplugged or malfunctioning. |
||
netBotz_prd_bot_amp5_sensor_replugged | 1.3.6.1.4.1.5528.30.100.190.7 |
NetBotz Amp 5 Sensor Replugged Trap. The sensor for the fifth AmpDetect was unplugged, but has been reconnected. |
||
netBotz_prd_bot_amp6_low_trap | 1.3.6.1.4.1.5528.30.100.200.1 |
NetBotz Amp 6 Low Trap. This trap indicates that the lower limit for the sixth amp detect has been exceeded. |
||
netBotz_prd_bot_amp6_high_trap | 1.3.6.1.4.1.5528.30.100.200.2 |
NetBotz Amp 6 High Trap. This trap indicates that the upper limit for the sixth amp detect has been exceeded. |
||
netBotz_prd_bot_amp6_trap_clear | 1.3.6.1.4.1.5528.30.100.200.3 |
NetBotz Amp 6 Cleared Trap. The trap has been cleared because the sixth amp detect value has returned to acceptable limits. |
||
netBotz_prd_bot_amp6_sensor_unplugged | 1.3.6.1.4.1.5528.30.100.200.6 |
NetBotz Amp 6 Sensor Unplugged Trap. The sensor for the sixth AmpDetect is unplugged or malfunctioning. |
||
netBotz_prd_bot_amp6_sensor_replugged | 1.3.6.1.4.1.5528.30.100.200.7 |
NetBotz Amp 6 Sensor Replugged Trap. The sensor for the sixth AmpDetect was unplugged, but has been reconnected. |
||
netBotz_prd_bot_amp7_low_trap | 1.3.6.1.4.1.5528.30.100.210.1 |
NetBotz Amp 7 Low Trap. This trap indicates that the lower limit for the seventh amp detect has been exceeded. |
||
netBotz_prd_bot_amp7_high_trap | 1.3.6.1.4.1.5528.30.100.210.2 |
NetBotz Amp 7 High Trap. This trap indicates that the upper limit for the seventh amp detect has been exceeded. |
||
netBotz_prd_bot_amp7_trap_clear | 1.3.6.1.4.1.5528.30.100.210.3 |
NetBotz Amp 7 Cleared Trap. The trap has been cleared because the seventh amp detect value has returned to acceptable limits. |
||
netBotz_prd_bot_amp7_sensor_unplugged | 1.3.6.1.4.1.5528.30.100.210.6 |
NetBotz Amp 7 Sensor Unplugged Trap. The sensor for the seventh AmpDetect is unplugged or malfunctioning. |
||
netBotz_prd_bot_amp7_sensor_replugged | 1.3.6.1.4.1.5528.30.100.210.7 |
NetBotz Amp 7 Sensor Replugged Trap. The sensor for the seventh AmpDetect was unplugged, but has been reconnected. |
||
netBotz_prd_bot_ext_temp5_low_trap | 1.3.6.1.4.1.5528.30.100.220.1 |
NetBotz External Temperature 5 Low Trap. This trap indicates that the lower limit for external temperature probe on port 5 has been exceeded. |
||
netBotz_prd_bot_ext_temp5_high_trap | 1.3.6.1.4.1.5528.30.100.220.2 |
NetBotz External Temperature 5 High Trap. This trap indicates that the upper limit for external temperature probe on port 5 has been exceeded. |
||
netBotz_prd_bot_ext_temp5_trap_clear | 1.3.6.1.4.1.5528.30.100.220.3 |
NetBotz External Temperature 5 Cleared Trap. The trap has been cleared because the temperature value for the temperature probe on port 5 has returned to acceptable limits. |
||
netBotz_prd_bot_ext_temp5_sensor_unplugged | 1.3.6.1.4.1.5528.30.100.220.6 |
NetBotz External Temperature 5 Sensor Unplugged Trap. The sensor is unplugged or malfunctioning. |
||
netBotz_prd_bot_ext_temp5_sensor_replugged | 1.3.6.1.4.1.5528.30.100.220.7 |
NetBotz External Temperature 5 Sensor Replugged Trap. The sensor was unplugged, but has been reconnected. |
||
netBotz_prd_bot_ext_temp6_low_trap | 1.3.6.1.4.1.5528.30.100.230.1 |
NetBotz External Temperature 6 Low Trap. This trap indicates that the lower limit for external temperature probe on port 6 has been exceeded. |
||
netBotz_prd_bot_ext_temp6_high_trap | 1.3.6.1.4.1.5528.30.100.230.2 |
NetBotz External Temperature 6 High Trap. This trap indicates that the upper limit for external temperature probe on port 6 has been exceeded. |
||
netBotz_prd_bot_ext_temp6_trap_clear | 1.3.6.1.4.1.5528.30.100.230.3 |
NetBotz External Temperature 6 Cleared Trap. The trap has been cleared because the temperature value for the temperature probe on port 6 has returned to acceptable limits. |
||
netBotz_prd_bot_ext_temp6_sensor_unplugged | 1.3.6.1.4.1.5528.30.100.230.6 |
NetBotz External Temperature 6 Sensor Unplugged Trap. The sensor is unplugged or malfunctioning. |
||
netBotz_prd_bot_ext_temp6_sensor_replugged | 1.3.6.1.4.1.5528.30.100.230.7 |
NetBotz External Temperature 6 Sensor Replugged Trap. The sensor was unplugged, but has been reconnected. |
||
netBotz_prd_bot_ext_temp7_low_trap | 1.3.6.1.4.1.5528.30.100.240.1 |
NetBotz External Temperature 7 Low Trap. This trap indicates that the lower limit for external temperature probe on port 7 has been exceeded. |
||
netBotz_prd_bot_ext_temp7_high_trap | 1.3.6.1.4.1.5528.30.100.240.2 |
NetBotz External Temperature 7 High Trap. This trap indicates that the upper limit for external temperature probe on port 7 has been exceeded. |
||
netBotz_prd_bot_ext_temp7_trap_clear | 1.3.6.1.4.1.5528.30.100.240.3 |
NetBotz External Temperature 7 Cleared Trap. The trap has been cleared because the temperature value for the temperature probe on port 7 has returned to acceptable limits. |
||
netBotz_prd_bot_ext_temp7_sensor_unplugged | 1.3.6.1.4.1.5528.30.100.240.6 |
NetBotz External Temperature 7 Sensor Unplugged Trap. The sensor is unplugged or malfunctioning. |
||
netBotz_prd_bot_ext_temp7_sensor_replugged | 1.3.6.1.4.1.5528.30.100.240.7 |
NetBotz External Temperature 7 Sensor Replugged Trap. The sensor was unplugged, but has been reconnected. |
||
netBotz_prd_bot_ext_dry5_triggered_trap | 1.3.6.1.4.1.5528.30.100.250.2 |
NetBotz External Dry Contact 5 Triggered Trap. This trap indicates that the state of the dry contact sensor on Ext5 matches the alarm value. |
||
netBotz_prd_bot_ext_dry5_trap_clear | 1.3.6.1.4.1.5528.30.100.250.3 |
NetBotz External Dry Contact 5 Cleared Trap. The trap has been cleared because the state of the dry contact sensor on Ext5 no longer matches the alarm value. |
||
netBotz_prd_bot_ext_dry6_triggered_trap | 1.3.6.1.4.1.5528.30.100.260.2 |
NetBotz External Dry Contact 6 Triggered Trap. This trap indicates that the state of the dry contact sensor on Ext6 matches the alarm value. |
||
netBotz_prd_bot_ext_dry6_trap_clear | 1.3.6.1.4.1.5528.30.100.260.3 |
NetBotz External Dry Contact 6 Cleared Trap. The trap has been cleared because the state of the dry contact sensor on Ext6 no longer matches the alarm value. |
||
netBotz_prd_bot_ext_dry7_triggered_trap | 1.3.6.1.4.1.5528.30.100.270.2 |
NetBotz External Dry Contact 7 Triggered Trap. This trap indicates that the state of the dry contact sensor on Ext7 matches the alarm value. |
||
netBotz_prd_bot_ext_dry7_trap_clear | 1.3.6.1.4.1.5528.30.100.270.3 |
NetBotz External Dry Contact 7 Cleared Trap. The trap has been cleared because the state of the dry contact sensor on Ext7 no longer matches the alarm value. |
||
netBotz_prd_bot_camera_motion_trap_tripped | 1.3.6.1.4.1.5528.30.100.280.2 |
NetBotz Camera Motion Sensor Tripped Trap. This trap indicates that the camera motion sensor has been triggered (motion has been detected). |
||
netBotz_prd_bot_camera_motion_trap_clear | 1.3.6.1.4.1.5528.30.100.280.3 |
NetBotz Camera Motion Cleared Trap. The trap has been cleared because the camera motion sensor has returned to normal (no longer is detecting motion). |
||
netBotz_prd_bot_ext_humi1_low_trap | 1.3.6.1.4.1.5528.30.100.290.1 |
NetBotz External Humidity 1 Low Trap. This trap indicates that the lower limit for external humidity probe on port 1 has been exceeded. |
||
netBotz_prd_bot_ext_humi1_high_trap | 1.3.6.1.4.1.5528.30.100.290.2 |
NetBotz External Humidity 1 High Trap. This trap indicates that the upper limit for external humidity probe on port 1 has been exceeded. |
||
netBotz_prd_bot_ext_humi1_trap_clear | 1.3.6.1.4.1.5528.30.100.290.3 |
NetBotz External Humidity 1 Cleared Trap. The trap has been cleared because the humidity value for the humidity probe on port 1 has returned to acceptable limits. |
||
netBotz_prd_bot_ext_humi1_sensor_unplugged | 1.3.6.1.4.1.5528.30.100.290.6 |
NetBotz External Humidity 1 Sensor Unplugged Trap. The sensor is unplugged or malfunctioning. |
||
netBotz_prd_bot_ext_humi1_sensor_replugged | 1.3.6.1.4.1.5528.30.100.290.7 |
NetBotz External Humidity 1 Sensor Replugged Trap. The sensor was unplugged, but has been reconnected. |
||
netBotz_prd_bot_ext_humi2_low_trap | 1.3.6.1.4.1.5528.30.100.300.1 |
NetBotz External Humidity 2 Low Trap. This trap indicates that the lower limit for external humidity probe on port 2 has been exceeded. |
||
netBotz_prd_bot_ext_humi2_high_trap | 1.3.6.1.4.1.5528.30.100.300.2 |
NetBotz External Humidity 2 High Trap. This trap indicates that the upper limit for external humidity probe on port 2 has been exceeded. |
||
netBotz_prd_bot_ext_humi2_trap_clear | 1.3.6.1.4.1.5528.30.100.300.3 |
NetBotz External Humidity 2 Cleared Trap. The trap has been cleared because the humidity value for the humidity probe on port 2 has returned to acceptable limits. |
||
netBotz_prd_bot_ext_humi2_sensor_unplugged | 1.3.6.1.4.1.5528.30.100.300.6 |
NetBotz External Humidity 2 Sensor Unplugged Trap. The sensor is unplugged or malfunctioning. |
||
netBotz_prd_bot_ext_humi2_sensor_replugged | 1.3.6.1.4.1.5528.30.100.300.7 |
NetBotz External Humidity 2 Sensor Replugged Trap. The sensor was unplugged, but has been reconnected. |
||
netBotz_prd_bot_ext_humi3_low_trap | 1.3.6.1.4.1.5528.30.100.310.1 |
NetBotz External Humidity 3 Low Trap. This trap indicates that the lower limit for external humidity probe on port 3 has been exceeded. |
||
netBotz_prd_bot_ext_humi3_high_trap | 1.3.6.1.4.1.5528.30.100.310.2 |
NetBotz External Humidity 3 High Trap. This trap indicates that the upper limit for external humidity probe on port 3 has been exceeded. |
||
netBotz_prd_bot_ext_humi3_trap_clear | 1.3.6.1.4.1.5528.30.100.310.3 |
NetBotz External Humidity 3 Cleared Trap. The trap has been cleared because the humidity value for the humidity probe on port 3 has returned to acceptable limits. |
||
netBotz_prd_bot_ext_humi3_sensor_unplugged | 1.3.6.1.4.1.5528.30.100.310.6 |
NetBotz External Humidity 3 Sensor Unplugged Trap. The sensor is unplugged or malfunctioning. |
||
netBotz_prd_bot_ext_humi3_sensor_replugged | 1.3.6.1.4.1.5528.30.100.310.7 |
NetBotz External Humidity 3 Sensor Replugged Trap. The sensor was unplugged, but has been reconnected. |
||
netBotz_prd_bot_ext_humi4_low_trap | 1.3.6.1.4.1.5528.30.100.320.1 |
NetBotz External Humidity 4 Low Trap. This trap indicates that the lower limit for external humidity probe on port 4 has been exceeded. |
||
netBotz_prd_bot_ext_humi4_high_trap | 1.3.6.1.4.1.5528.30.100.320.2 |
NetBotz External Humidity 4 High Trap. This trap indicates that the upper limit for external humidity probe on port 4 has been exceeded. |
||
netBotz_prd_bot_ext_humi4_trap_clear | 1.3.6.1.4.1.5528.30.100.320.3 |
NetBotz External Humidity 4 Cleared Trap. The trap has been cleared because the humidity value for the humidity probe on port 4 has returned to acceptable limits. |
||
netBotz_prd_bot_ext_humi4_sensor_unplugged | 1.3.6.1.4.1.5528.30.100.320.6 |
NetBotz External Humidity 4 Sensor Unplugged Trap. The sensor is unplugged or malfunctioning. |
||
netBotz_prd_bot_ext_humi4_sensor_replugged | 1.3.6.1.4.1.5528.30.100.320.7 |
NetBotz External Humidity 4 Sensor Replugged Trap. The sensor was unplugged, but has been reconnected. |
||
netBotz_prd_bot_ext_humi5_low_trap | 1.3.6.1.4.1.5528.30.100.330.1 |
NetBotz External Humidity 5 Low Trap. This trap indicates that the lower limit for external humidity probe on port 5 has been exceeded. |
||
netBotz_prd_bot_ext_humi5_high_trap | 1.3.6.1.4.1.5528.30.100.330.2 |
NetBotz External Humidity 5 High Trap. This trap indicates that the upper limit for external humidity probe on port 5 has been exceeded. |
||
netBotz_prd_bot_ext_humi5_trap_clear | 1.3.6.1.4.1.5528.30.100.330.3 |
NetBotz External Humidity 5 Cleared Trap. The trap has been cleared because the humidity value for the humidity probe on port 5 has returned to acceptable limits. |
||
netBotz_prd_bot_ext_humi5_sensor_unplugged | 1.3.6.1.4.1.5528.30.100.330.6 |
NetBotz External Humidity 5 Sensor Unplugged Trap. The sensor is unplugged or malfunctioning. |
||
netBotz_prd_bot_ext_humi5_sensor_replugged | 1.3.6.1.4.1.5528.30.100.330.7 |
NetBotz External Humidity 5 Sensor Replugged Trap. The sensor was unplugged, but has been reconnected. |
||
netBotz_prd_bot_ext_humi6_low_trap | 1.3.6.1.4.1.5528.30.100.340.1 |
NetBotz External Humidity 6 Low Trap. This trap indicates that the lower limit for external humidity probe on port 6 has been exceeded. |
||
netBotz_prd_bot_ext_humi6_high_trap | 1.3.6.1.4.1.5528.30.100.340.2 |
NetBotz External Humidity 6 High Trap. This trap indicates that the upper limit for external humidity probe on port 6 has been exceeded. |
||
netBotz_prd_bot_ext_humi6_trap_clear | 1.3.6.1.4.1.5528.30.100.340.3 |
NetBotz External Humidity 6 Cleared Trap. The trap has been cleared because the humidity value for the humidity probe on port 6 has returned to acceptable limits. |
||
netBotz_prd_bot_ext_humi6_sensor_unplugged | 1.3.6.1.4.1.5528.30.100.340.6 |
NetBotz External Humidity 6 Sensor Unplugged Trap. The sensor is unplugged or malfunctioning. |
||
netBotz_prd_bot_ext_humi6_sensor_replugged | 1.3.6.1.4.1.5528.30.100.340.7 |
NetBotz External Humidity 6 Sensor Replugged Trap. The sensor was unplugged, but has been reconnected. |
||
netBotz_prd_bot_ext_humi7_low_trap | 1.3.6.1.4.1.5528.30.100.350.1 |
NetBotz External Humidity 7 Low Trap. This trap indicates that the lower limit for external humidity probe on port 7 has been exceeded. |
||
netBotz_prd_bot_ext_humi7_high_trap | 1.3.6.1.4.1.5528.30.100.350.2 |
NetBotz External Humidity 7 High Trap. This trap indicates that the upper limit for external humidity probe on port 7 has been exceeded. |
||
netBotz_prd_bot_ext_humi7_trap_clear | 1.3.6.1.4.1.5528.30.100.350.3 |
NetBotz External Humidity 7 Cleared Trap. The trap has been cleared because the humidity value for the humidity probe on port 7 has returned to acceptable limits. |
||
netBotz_prd_bot_ext_humi7_sensor_unplugged | 1.3.6.1.4.1.5528.30.100.350.6 |
NetBotz External Humidity 7 Sensor Unplugged Trap. The sensor is unplugged or malfunctioning. |
||
netBotz_prd_bot_ext_humi7_sensor_replugged | 1.3.6.1.4.1.5528.30.100.350.7 |
NetBotz External Humidity 7 Sensor Replugged Trap. The sensor was unplugged, but has been reconnected. |
||
netBotz_prd_WallBotz_300 | 1.3.6.1.4.1.5528.30.1000 | |||
netBotz_prd_RackBotz_300 | 1.3.6.1.4.1.5528.30.1001 | |||
netBotz_prd_RackBotz_300U | 1.3.6.1.4.1.5528.30.1002 | |||
netBotz_prd_WallBotz_400 | 1.3.6.1.4.1.5528.30.1003 | |||
netBotz_prd_RackBotz_400 | 1.3.6.1.4.1.5528.30.1004 | |||
netBotz_prd_RackBotz_303 | 1.3.6.1.4.1.5528.30.1006 | |||
netBotz_prd_WallBotz_310 | 1.3.6.1.4.1.5528.30.1007 | |||
netBotz_prd_RackBotz_310 | 1.3.6.1.4.1.5528.30.1008 | |||
netBotz_prd_WallBotz_300B | 1.3.6.1.4.1.5528.30.1009 | |||
netBotz_prd_WallBotz_300C | 1.3.6.1.4.1.5528.30.1100 | |||
netBotz_prd_RackBotz_300C | 1.3.6.1.4.1.5528.30.1101 | |||
netBotz_prd_RackBotz_300UC | 1.3.6.1.4.1.5528.30.1102 | |||
netBotz_prd_WallBotz_400C | 1.3.6.1.4.1.5528.30.1103 | |||
netBotz_prd_RackBotz_400C | 1.3.6.1.4.1.5528.30.1104 | |||
netBotz_prd_RackBotz_303C | 1.3.6.1.4.1.5528.30.1106 | |||
netBotz_prd_WallBotz_310C | 1.3.6.1.4.1.5528.30.1107 | |||
netBotz_prd_RackBotz_310C | 1.3.6.1.4.1.5528.30.1108 | |||
netBotz_prd_WallBotz_300BC | 1.3.6.1.4.1.5528.30.1109 | |||
netBotz_prd_WallBotz_300E | 1.3.6.1.4.1.5528.30.1200 | |||
netBotz_prd_RackBotz_300E | 1.3.6.1.4.1.5528.30.1201 | |||
netBotz_prd_RackBotz_300UE | 1.3.6.1.4.1.5528.30.1202 | |||
netBotz_prd_WallBotz_400E | 1.3.6.1.4.1.5528.30.1203 | |||
netBotz_prd_RackBotz_400E | 1.3.6.1.4.1.5528.30.1204 | |||
netBotz_prd_RackBotz_303E | 1.3.6.1.4.1.5528.30.1206 | |||
netBotz_prd_WallBotz_310E | 1.3.6.1.4.1.5528.30.1207 | |||
netBotz_prd_RackBotz_310E | 1.3.6.1.4.1.5528.30.1208 | |||
netBotz_prd_WallBotz_300BE | 1.3.6.1.4.1.5528.30.1209 | |||
expPortTable | 1.3.6.1.4.1.5528.31 | no-access |
A list of expansion port entries. |
|
1.3.6.1.4.1.5528.31.1 | no-access |
An expansion port entry for a single port |
||
expPort_module_id | 1.3.6.1.4.1.5528.31.1.1 | displaystring | read-write |
The module ID of the sensor module installed. Blank string indicates that no module is installed. |
expPort_module_type | 1.3.6.1.4.1.5528.31.1.2 | displaystring | read-write |
The type of sensor module installed. NONE=no module, AMP=AmpDetect module, TEMP=temperature sensor, DRY=dry contact sensor. |
expPort_label | 1.3.6.1.4.1.5528.31.1.3 | displaystring | read-write |
The label for the expansion port. Ports default to the label 'Extn', for port n. |
expPort_amps | 1.3.6.1.4.1.5528.31.1.20 | integer | read-only |
The reading of the amperage probe, in milliamps. |
expPort_total_amp_seconds | 1.3.6.1.4.1.5528.31.1.21 | integer | read-only |
The accumulated total of amp-seconds on the AmpDetect. |
expPort_total_amp_seconds_since_time | 1.3.6.1.4.1.5528.31.1.22 | integer | read-write |
The UTC time (seconds since 1/1/1970) of the beginning of the accumulated total of amp-seconds on the AmpDetect. Writing a value to this attribute resets the accumulated total amp-seconds and sets this time to the current time. |
expPort_amps_enabled | 1.3.6.1.4.1.5528.31.1.23 | integer | read-write |
Amperage probe alarm enabled(1) or disabled(0). |
expPort_amps_min | 1.3.6.1.4.1.5528.31.1.24 | integer | read-write |
The amperage probe minimum, from 0 to 30000 milliamps. |
expPort_amps_max | 1.3.6.1.4.1.5528.31.1.25 | integer | read-write |
The amperage probe maximum, from 0 to 30000 milliamps. |
expPort_amps_uV_per_10mA | 1.3.6.1.4.1.5528.31.1.26 | integer | read-write |
The scaling factor used for the amperage probe to convert microvolts measured from the Amp Detect into 10s of milliamps of current. Needs to be set based on the type of Amp Detect module installed. |
expPort_amps_max_range | 1.3.6.1.4.1.5528.31.1.27 | integer | read-write |
The maximum RMS milliamps measureable by the AmpDetect. |
expPort_ext_temp | 1.3.6.1.4.1.5528.31.1.40 | integer | read-only |
The reading of the external temperature probe, in degrees F or degrees C (depends on netBotz-ismetric). |
expPort_ext_temp_enabled | 1.3.6.1.4.1.5528.31.1.41 | integer | read-write |
External temperature probe alarm enabled(1) or disabled(0). |
expPort_ext_temp_min | 1.3.6.1.4.1.5528.31.1.42 | integer | read-write |
The external temperature probe minimum, in degrees F or degrees C (depends on netBotz-ismetric). |
expPort_ext_temp_max | 1.3.6.1.4.1.5528.31.1.43 | integer | read-write |
The external temperature probe maximum, in degrees F or degrees C (depends on netBotz-ismetric). |
expPort_ext_temp_uV_per_degreeC | 1.3.6.1.4.1.5528.31.1.44 | integer | read-write |
The scaling factor used for the external temperature probe to convert microvolts measured from the temperature sensor into degrees C. Needs to be set based on the type of temperature sensor module installed. |
expPort_ext_temp_uV_at_0_degreeC | 1.3.6.1.4.1.5528.31.1.45 | integer | read-write |
The offset used for the external temperature probe of microvolts measured from the temperature sensor at zero degrees C. Needs to be set based on the type of temperature sensor module installed. |
expPort_ext_temp_min_range | 1.3.6.1.4.1.5528.31.1.46 | integer | read-write |
The minimum temperature measureable by the temperature sensor, in tenths of a degree C. Needs to be set based on the type of temperature sensor module installed. |
expPort_ext_temp_max_range | 1.3.6.1.4.1.5528.31.1.47 | integer | read-write |
The maximum temperature measureable by the temperature sensor, in tenths of a degree C. Needs to be set based on the type of temperature sensor module installed. |
expPort_ext_dry | 1.3.6.1.4.1.5528.31.1.60 | integer | read-only |
The current value of the external dry contact sensor: 0=Open, 1=Closed, -1=N/A |
expPort_ext_dry_alarm_value | 1.3.6.1.4.1.5528.31.1.61 | integer | read-write |
The value to generate alarms on for the external dry contact sensor: 0=Open, 1=Closed |
expPort_ext_dry_enabled | 1.3.6.1.4.1.5528.31.1.62 | integer | read-write |
External dry contact sensor alarm enabled(1) or disabled(0). |
expPort_ext_dry_label | 1.3.6.1.4.1.5528.31.1.63 | displaystring | read-write |
The sensor name/label for the dry contact sensor |
expPort_ext_dry_open_label | 1.3.6.1.4.1.5528.31.1.64 | displaystring | read-write |
The sensor name/label for the open(0) state for the dry contact sensor |
expPort_ext_dry_closed_label | 1.3.6.1.4.1.5528.31.1.65 | displaystring | read-write |
The sensor name/label for the closed(0) state for the dry contact sensor |
expPort_ext_dry_open_to_close_millis | 1.3.6.1.4.1.5528.31.1.66 | integer | read-write |
The minimum number of milliseconds that the dry contact sensor must read closed before the state is changed from open to closed. |
expPort_ext_dry_close_to_open_millis | 1.3.6.1.4.1.5528.31.1.67 | integer | read-write |
The minimum number of milliseconds that the dry contact sensor must read openbefore the state is changed from closed to open. |
expPort_ext_dry_response | 1.3.6.1.4.1.5528.31.1.68 | displaystring | read-write |
The type of alert response for the dry contact sensor: ALERT=e-mail with no pictures, CAMERA=e-mail with pictures from camera. |
expPort_ext_humi | 1.3.6.1.4.1.5528.31.1.80 | integer | read-only |
The reading of the external humidity probe, in percent. |
expPort_ext_humi_enabled | 1.3.6.1.4.1.5528.31.1.81 | integer | read-write |
External humidity probe alarm enabled(1) or disabled(0). |
expPort_ext_humi_min | 1.3.6.1.4.1.5528.31.1.82 | integer | read-write |
The external humidity probe minimum, in percent. |
expPort_ext_humi_max | 1.3.6.1.4.1.5528.31.1.83 | integer | read-write |
The external humidity probe maximum, in percent. |
expPort_ext_humi_uV_per_percent | 1.3.6.1.4.1.5528.31.1.84 | integer | read-write |
The scaling factor used for the external humidity probe to convert microvolts measured from the humidity sensor into percent. Needs to be set based on the type of humidity sensor module installed. |
expPort_ext_humi_uV_at_0_percent | 1.3.6.1.4.1.5528.31.1.85 | integer | read-write |
The offset used for the external humidity probe of microvolts measured from the humidity sensor at zero percent. Needs to be set based on the type of humidity sensor module installed. |
expPort_ext_humi_min_range | 1.3.6.1.4.1.5528.31.1.86 | integer | read-write |
The minimum humidity measureable by the humidity sensor, in percent. Needs to be set based on the type of humidity sensor module installed. |
expPort_ext_humi_max_range | 1.3.6.1.4.1.5528.31.1.87 | integer | read-write |
The maximum humidity measureable by the humidity sensor, in percent. Needs to be set based on the type of humidity sensor module installed. |
netBotz_metric | 1.3.6.1.4.1.5528.32 | |||
netBotz_metric_onboard | 1.3.6.1.4.1.5528.32.10 | |||
netBotz_metric_onboard_model | 1.3.6.1.4.1.5528.32.10.1 | displaystring | read-only |
The model description of the appliance. |
netBotz_metric_onboard_temp | 1.3.6.1.4.1.5528.32.10.2 | integer | read-only |
The reading of the built-in temperature probe, in tenths of a degree C. |
netBotz_metric_onboard_humidity | 1.3.6.1.4.1.5528.32.10.3 | integer | read-only |
The reading of the built-in humidity probe, in percent. |
netBotz_metric_onboard_airflow | 1.3.6.1.4.1.5528.32.10.4 | integer | read-only |
The reading of the built-in airflow probe, in meters/minute. |
netBotz_metric_onboard_audio | 1.3.6.1.4.1.5528.32.10.5 | integer | read-only |
The reading of the built-in audio alarm probe on/off. |
netBotz_metric_onboard_doorajar | 1.3.6.1.4.1.5528.32.10.6 | integer | read-only |
The reading of the door switch probe open(1) or closed(0). |
netBotz_metric_onboard_temp_min | 1.3.6.1.4.1.5528.32.10.7 | integer | read-only |
The temperature probe minimum, from 1 to 50 degrees C in tenths of a degree C. |
netBotz_metric_onboard_temp_max | 1.3.6.1.4.1.5528.32.10.8 | integer | read-only |
The temperature probe maximum, from 1 to 50 degrees C in tenths of a degree C. |
netBotz_metric_onboard_humidity_min | 1.3.6.1.4.1.5528.32.10.9 | integer | read-only |
The humidity probe minimum, from 10 to 90 percent. |
netBotz_metric_onboard_humidity_max | 1.3.6.1.4.1.5528.32.10.10 | integer | read-only |
The humidity probe maximum, from 10 to 90 percent. |
netBotz_metric_onboard_airflow_mins | 1.3.6.1.4.1.5528.32.10.11 | integer | read-only |
Minutes without airflow before alarm set. |
netBotz_metric_onboard_audio_secs | 1.3.6.1.4.1.5528.32.10.12 | integer | read-only |
Seconds of alarm audio before alarm set. |
netBotz_metric_onboard_switch_state | 1.3.6.1.4.1.5528.32.10.13 | integer | read-only |
Switch state setting. The state controls which condition of the door switch indicates an alarm. If set to 0, alarm is set when the switch is closed. If set to 1, alarm is set when the switch is open. |
netBotz_metric_onboard_audio_level | 1.3.6.1.4.1.5528.32.10.14 | integer | read-only |
Audio level setting, this is the relative audio level, from 0-11, above which an alarm will be sent. |
netBotz_metric_onboard_airflow_level | 1.3.6.1.4.1.5528.32.10.15 | integer | read-only |
Airflow alert level. This is the level, in meters per second, below which an alarm will be sent. |
netBotz_metric_onboard_cam_motion | 1.3.6.1.4.1.5528.32.10.16 | integer | read-only |
The current motion reading for the camera motion sensor (0=none, 1=motion detected, -1=not licensed). |
netBotz_metric_onboard_cam_motion_sensitivity | 1.3.6.1.4.1.5528.32.10.17 | integer | read-only |
Camera motion sensor sensitivity: 1=max, 15=min, 0=disabled. |
netBotz_snmp | 1.3.6.1.4.1.5528.40 | |||
netBotz_snmp_traptarget | 1.3.6.1.4.1.5528.40.1 | ipaddress | read-write |
Target of traps from the NetBotz device. This field contains the IP address where NetBotz traps are to be sent. |
netBotz_snmp_community | 1.3.6.1.4.1.5528.40.2 | displaystring | read-write |
The read/write community of the NetBotz device. |
netBotz_snmp_timeout | 1.3.6.1.4.1.5528.40.3 | integer | read-write |
SNMP Timeout period. |
netBotz_snmp_retries | 1.3.6.1.4.1.5528.40.4 | integer | read-write |
SNMP Retry count. |
netBotz_userid_1 | 1.3.6.1.4.1.5528.40.5 | displaystring | read-write |
The userID of the supervisor account (write-only). |
netBotz_password_1 | 1.3.6.1.4.1.5528.40.6 | displaystring | read-write |
The password of the supervisor account (write-only). |
netBotz_userid_2 | 1.3.6.1.4.1.5528.40.7 | displaystring | read-write |
The userID of the full read access account (write-only). |
netBotz_password_2 | 1.3.6.1.4.1.5528.40.8 | displaystring | read-write |
The password of the full read access account (write-only). |
netBotz_userid_3 | 1.3.6.1.4.1.5528.40.9 | displaystring | read-write |
The userID of the minimum read access account (write-only). |
netBotz_password_3 | 1.3.6.1.4.1.5528.40.10 | displaystring | read-write |
The password of the minimum read access account (write-only). |
netBotz_snmp_traptarget2 | 1.3.6.1.4.1.5528.40.11 | ipaddress | read-write |
Second target of traps from the NetBotz device. This field contains an additional IP address where NetBotz traps are to be sent. |
netBotz_snmp_read_community | 1.3.6.1.4.1.5528.40.12 | displaystring | read-write |
The read-only community of the NetBotz device. |
netBotz_device | 1.3.6.1.4.1.5528.50 | |||
netBotz_dev_host | 1.3.6.1.4.1.5528.50.1 | displaystring | read-write |
NetBotz device's host name. |
netBotz_dev_domain | 1.3.6.1.4.1.5528.50.2 | displaystring | read-write |
NetBotz device's default DNS domain. |
netBotz_dev_ip | 1.3.6.1.4.1.5528.50.3 | ipaddress | read-write |
NetBotz device's IP address. |
netBotz_dev_netmask | 1.3.6.1.4.1.5528.50.4 | ipaddress | read-write |
NetBotz device's netmask. |
netBotz_dev_gateway | 1.3.6.1.4.1.5528.50.5 | ipaddress | read-write |
NetBotz device's default gateway/router. 0.0.0.0 if not defined. |
netBotz_dev_primarydns | 1.3.6.1.4.1.5528.50.6 | ipaddress | read-write |
Primary Domain Name Server. 0.0.0.0 if not defined. |
netBotz_dev_secondarydns | 1.3.6.1.4.1.5528.50.7 | ipaddress | read-write |
Secondary Domain Name Server. 0.0.0.0 if not defined. |
netBotz_dev_smtp | 1.3.6.1.4.1.5528.50.8 | displaystring | read-write |
SMTP server address. This is the mail server used for sending alert e-mails. |
netBotz_dev_smtpport | 1.3.6.1.4.1.5528.50.9 | integer | read-write |
SMTP port. Port number of SMTP server used for sending alert e-mails. |
netBotz_dev_popport | 1.3.6.1.4.1.5528.50.10 | integer | read-write |
POP port. Currently, not used. |
netBotz_dev_loglevel | 1.3.6.1.4.1.5528.50.11 | integer | read-write |
This field contains the log level of the NetBotz device. Log messages will be filtered, so that only same or lower-level messages will be passed. The default log level is 5, for warnings and lower levels. The log levels are the following: 1 - emergency 2 - alert 3 - critical 4 - error 5 - warning 6 - notice 7 - info 8 - trace |
netBotz_dev_primaryemail | 1.3.6.1.4.1.5528.50.14 | displaystring | read-write |
The primary email addresses for alerts and messages (list separated by commas for multiple addresses). |
netBotz_dev_secondaryemail | 1.3.6.1.4.1.5528.50.15 | displaystring | read-write |
The secondary email address for alerts and messages (list separated by commas for multiple addresses). |
netBotz_dev_serialno | 1.3.6.1.4.1.5528.50.17 | displaystring | read-only |
The serial number of the NetBotz device. |
netBotz_dev_pop | 1.3.6.1.4.1.5528.50.18 | displaystring | read-write |
POP server name. Currently, not used. |
netBotz_dev_version | 1.3.6.1.4.1.5528.50.19 | displaystring | read-only |
The current NetBotz device firmware version. |
netBotz_dev_registered | 1.3.6.1.4.1.5528.50.20 | integer | read-only |
Indicates if the device has been registered with NetBotz, Inc. 1=registered, 0=not registered. |
netBotz_default_applet | 1.3.6.1.4.1.5528.50.21 | integer | read-write |
Setting to control if default web page should launch applet by default(1) or the HTML status page(0). |
netBotz_guibar_color | 1.3.6.1.4.1.5528.50.22 | integer | read-write |
Setting for color of GUI bar (RGB). Value = 0xRRGGBB. |
netBotz_locale | 1.3.6.1.4.1.5528.50.23 | displaystring | read-write |
The locale ID of the NetBotz device. Format is ISO 639 language (lower case), an underscore, and ISO 3166 country (upper case). Some locales are just the ISO 639 language code. |
netBotz_timezone | 1.3.6.1.4.1.5528.50.24 | displaystring | read-write |
The timezone ID of the NetBotz device. |
netBotz_24hourpreferred | 1.3.6.1.4.1.5528.50.25 | integer | read-write |
Indicates if 24-hour(1) versus 12-hour(0) time format is preferred. |
netBotz_utc_clock | 1.3.6.1.4.1.5528.50.26 | integer | read-write |
Current time of clock on NetBotz device, in UTC seconds (seconds since 1/1/1970 12:00am GMT). |
netBotz_ismetric | 1.3.6.1.4.1.5528.50.27 | integer | read-only |
Units are metric (1) or U.S. (0). Applies to temperature and airflow rate. |
netBotz_alert_url | 1.3.6.1.4.1.5528.50.28 | displaystring | read-write |
The URL, if defined, to which non-picture alerts are HTTP POSTed |
netBotz_picture_alert_url | 1.3.6.1.4.1.5528.50.29 | displaystring | read-write |
The URL, if defined, to which picture alerts are HTTP POSTed, using multipart/form-data encoding. |
netBotz_sensor_data_url | 1.3.6.1.4.1.5528.50.30 | displaystring | read-write |
The URL, if defined, to which sensor data is periodically HTTP POSTed. |
netBotz_alert_url_logon | 1.3.6.1.4.1.5528.50.31 | displaystring | read-write |
The user ID and password, if defined, used for POSTing non-picture alerts. Field is write-only, and formatted / |
netBotz_picture_alert_url_logon | 1.3.6.1.4.1.5528.50.32 | displaystring | read-write |
The user ID and password, if defined, used for POSTing picture alerts. Field is write-only, and formatted / |
netBotz_sensor_data_url_logon | 1.3.6.1.4.1.5528.50.33 | displaystring | read-write |
The user ID and password, if defined, used for POSTing sensor data. Field is write-only, and formatted / |
netBotz_sensor_data_url_period | 1.3.6.1.4.1.5528.50.34 | integer | read-write |
Default number of minutes between periodic sensor data HTTP POSTs. |
netBotz_sensor_data_url_flags | 1.3.6.1.4.1.5528.50.35 | integer | read-write |
Option flags for data POSTs of sensor data. Bit 0=1 if current picture should be included. Bits 1-31 are reserved. |
netBotz_dev_backup_smtp | 1.3.6.1.4.1.5528.50.36 | displaystring | read-write |
Backup SMTP server address. This is the backup mail server used for sending alert e-mails. |
netBotz_dev_tertiarydns | 1.3.6.1.4.1.5528.50.37 | ipaddress | read-write |
Tertiary Domain Name Server. 0.0.0.0 if not defined. |
netBotz_dev_ntp_server | 1.3.6.1.4.1.5528.50.38 | displaystring | read-write |
NTP (Network Time Protocol) Server configured for appliance. |
netBotz_dev_ntp_period | 1.3.6.1.4.1.5528.50.39 | integer | read-write |
Hours between automatic refreshes of the appliance clock using the NTP server. |
netBotz_dev_socks_server | 1.3.6.1.4.1.5528.50.40 | displaystring | read-write |
Socks V4 or V5 proxy server configured for appliance. |
netBotz_dev_socks_portnum | 1.3.6.1.4.1.5528.50.41 | integer | read-write |
Port number of Socks Proxy. |
netBotz_dev_socks_user_id | 1.3.6.1.4.1.5528.50.42 | displaystring | read-write |
User ID for Socks V4 or V5 proxy server configured for appliance. |
netBotz_dev_socks_password | 1.3.6.1.4.1.5528.50.43 | displaystring | read-write |
Password for Socks V4 or V5 proxy server configured for appliance. |
netBotz_alert_ftp_site | 1.3.6.1.4.1.5528.50.44 | displaystring | read-write |
The hostname or dotted-decimal IP address of the FTP server to deliver alerts to |
netBotz_alert_ftp_path | 1.3.6.1.4.1.5528.50.45 | displaystring | read-write |
The directory on the FTP server to store alerts in. |
netBotz_alert_ftp_filename | 1.3.6.1.4.1.5528.50.46 | displaystring | read-write |
The base filename for the files on the FTP server to store alerts in. |
netBotz_alert_ftp_logon | 1.3.6.1.4.1.5528.50.47 | displaystring | read-write |
The user-id and password on the FTP server to store alerts in. Field is write-only, and formatted / |
netBotz_sensor_ftp_site | 1.3.6.1.4.1.5528.50.48 | displaystring | read-write |
The hostname or dotted-decimal IP address of the FTP server to deliver periodic sensor reports to |
netBotz_sensor_ftp_path | 1.3.6.1.4.1.5528.50.49 | displaystring | read-write |
The directory on the FTP server to store periodic sensor reports in. |
netBotz_sensor_ftp_filename | 1.3.6.1.4.1.5528.50.50 | displaystring | read-write |
The base filename for the files on the FTP server to store periodic sensor reports in. |
netBotz_sensor_ftp_logon | 1.3.6.1.4.1.5528.50.51 | displaystring | read-write |
The user-id and password on the FTP server to store sensor reports in. Field is write-only, and formatted / |
netBotz_sensor_ftp_period | 1.3.6.1.4.1.5528.50.52 | integer | read-write |
The period, in minutes, between delivery of sensor data reports. |
netBotz_use_syslog | 1.3.6.1.4.1.5528.50.53 | integer | read-write |
Enable syslog |
netBotz_syslog_address | 1.3.6.1.4.1.5528.50.54 | displaystring | read-write |
Host address to use for syslogging |
netBotz_syslog_facility | 1.3.6.1.4.1.5528.50.55 | integer | read-write |
Syslog facility code |
netBotz_color_balance | 1.3.6.1.4.1.5528.50.56 | displaystring | read-write |
Color balance for color camera. AUTO=automatic, FLUOR=fluorescent, DAY=daylight, INCAND=incandescent, x/y=Custom (scale red by x/64, scale blue by y/64) |
netBotz_addonapp | 1.3.6.1.4.1.5528.60 | |||
device_crawlers_trap_target_index | 1.3.6.1.4.1.5528.60.2 | |||
branch_checker_trap_target_index | 1.3.6.1.4.1.5528.60.3 | |||
vendor_netBotz | 1.3.6.1.4.1.5528.60.5528 | |||
device_crawlers_trap | 1.3.6.1.4.1.5528.60.5528.2 | |||
branch_checker_trap | 1.3.6.1.4.1.5528.60.5528.3 | |||
netBotz_device_crawlers_value_low_alert_trap | 1.3.6.1.4.1.5528.60.5528.20.1 |
NetBotz Device Crawlers Value Low Trap. This trap indicates that the lower limit on a monitored value has been exceeded. |
||
netBotz_device_crawlers_value_high_alert_trap | 1.3.6.1.4.1.5528.60.5528.20.2 |
NetBotz Device Crawlers Value High Trap. This trap indicates that the upper limit on a monitored value has been exceeded. |
||
netBotz_device_crawlers_clear_alert_trap | 1.3.6.1.4.1.5528.60.5528.20.3 |
NetBotz Device Crawlers Clear Trap. This trap indicates that the previous alert condition has been cleared. |
||
netBotz_device_crawlers_offline_alert_trap | 1.3.6.1.4.1.5528.60.5528.20.4 |
NetBotz Device Crawlers Offline Trap. This trap indicates that a monitored target could not be contacted. |
||
netBotz_device_crawlers_online_alert_trap | 1.3.6.1.4.1.5528.60.5528.20.5 |
NetBotz Device Crawlers Online Trap. This trap indicates that a monitored target that previously could not be contacted has now been contacted successfully. |
||
netBotz_device_crawlers_ifopstatus_alert_trap | 1.3.6.1.4.1.5528.60.5528.20.8 |
NetBotz Device Crawlers Interface Operational Status Trap. This trap indicates that one or more of a monitored target's network interfaces operational status is not equal to the desired status. |
||
netBotz_branch_checker_clear_alert_trap | 1.3.6.1.4.1.5528.60.5528.30.3 |
NetBotz Branch Checker Clear Trap. This trap indicates that the previous alert condition has been cleared. |
||
netBotz_branch_checker_offline_alert_trap | 1.3.6.1.4.1.5528.60.5528.30.4 |
NetBotz Branch Checker Offline Trap. This trap indicates that a monitored target could not be contacted. |
||
netBotz_branch_checker_online_alert_trap | 1.3.6.1.4.1.5528.60.5528.30.5 |
NetBotz Branch Checker Online Trap. This trap indicates that a monitored target that previously could not be contacted has now been contacted successfully. |
||
netBotz_branch_checker_target_error_trap | 1.3.6.1.4.1.5528.60.5528.30.12 |
NetBotz Branch Target Error Trap. This trap indicates that a monitored target could be contacted, but not withing the timeout period specified. |
||
netBotz_addonapp_trap | 1.3.6.1.4.1.5528.61 | |||
device_crawlers_trap_attrib | 1.3.6.1.4.1.5528.61.2 | |||
device_crawlers_trap_index | 1.3.6.1.4.1.5528.61.2.20 | integer | read-only |
The ID of the device crawler which sent the last trap. |
device_crawlers_trap_address | 1.3.6.1.4.1.5528.61.2.21 | ipaddress | read-only |
The IP address of the appliance actually creating the last trap. |
device_crawlers_trap_oid | 1.3.6.1.4.1.5528.61.2.22 | object identifier | read-only |
The object id of the attribute on the device crawlers target device which is the concern of the last trap. The second to last element indicates the index of the source of the problem (1=ICMP Ping, 2=SNMP Agent Status, 256-10239=Network Interfaces 1-9984, 10240 and above, indicates Advanced crawlers data). The last element is the decimal representation of the IP address of the source of the problem. |
device_crawlers_trap_botoid | 1.3.6.1.4.1.5528.61.2.23 | object identifier | read-only |
The object id of the device crawlers attribute on the NetBotz device which is the concern of the last trap. |
device_crawlers_trap_value | 1.3.6.1.4.1.5528.61.2.24 | integer | read-only |
The integer value of the device crawlers attribute associated with the last trap. |
device_crawlers_trap_stringvalue | 1.3.6.1.4.1.5528.61.2.25 | displaystring | read-only |
The string representation of the value of the device crawlers attribute associated with the last trap. |
device_crawlers_trap_date | 1.3.6.1.4.1.5528.61.2.26 | integer | read-only |
The date and time of a specific device crawlers trap. This field contains the number of seconds elapsed since midnight (00:00:00), January 1, 1970 |
device_crawlers_trap_attrib_index | 1.3.6.1.4.1.5528.61.2.27 | integer | read-only |
The identification number of the device crawlers attribute in error |
device_crawlers_crawlers_trap_desc | 1.3.6.1.4.1.5528.61.2.28 | displaystring | read-only |
Description of the Device Crawlers Trap Attribute |
branch_checker_trap_attrib | 1.3.6.1.4.1.5528.61.3 | |||
branch_checker_trap_index | 1.3.6.1.4.1.5528.61.3.20 | integer | read-only |
The ID of the branch checker which sent the last trap. |
branch_checker_trap_address | 1.3.6.1.4.1.5528.61.3.21 | ipaddress | read-only |
The IP address of the appliance actually creating the last trap. |
branch_checker_trap_oid | 1.3.6.1.4.1.5528.61.3.22 | object identifier | read-only |
The object id of the attribute on the branch checker target device which is the concern of the last trap The second to last element is the index of the source of the problem (256-260=SMTP Server, 1024-1026=DNS Server, 1536-1538=Web Server, 2048-2052=Generic Server). The last element is the decimal representation of the IP address of the source of the problem. |
branch_checker_trap_botoid | 1.3.6.1.4.1.5528.61.3.23 | object identifier | read-only |
The object id of the branch checker attribute on the NetBotz device which is the concern of the last trap. The second to last element is the index of the source of the problem (256-260=SMTP Server, 1024-1026=DNS Server, 1536-1538=Web Server, 2048-2052=Generic Server). The last element is the decimal representation of the IP address of the source of the problem. |
branch_checker_trap_value | 1.3.6.1.4.1.5528.61.3.24 | integer | read-only |
The integer value of the branch checker attribute associated with the last trap. |
branch_checker_trap_stringvalue | 1.3.6.1.4.1.5528.61.3.25 | displaystring | read-only |
The string representation of the value of the branch checker attribute associated with the last trap. |
branch_checker_trap_date | 1.3.6.1.4.1.5528.61.3.26 | integer | read-only |
The date and time of a specific branch checker trap. This field contains the number of seconds elapsed since midnight (00:00:00), January 1, 1970 |
branch_checker_trap_attrib_index | 1.3.6.1.4.1.5528.61.3.27 | integer | read-only |
The identification number of the branch checker attribute in error |
branch_checker_trap_desc | 1.3.6.1.4.1.5528.61.3.28 | displaystring | read-only |
Description of the Branch Checker Trap Attribute |