Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 teps 1.3.6.1.4.1.10520
             controllermibs 1.3.6.1.4.1.10520.2
                 release 1.3.6.1.4.1.10520.2.1
                     ne843 1.3.6.1.4.1.10520.2.1.3
MIB for NE843 Power System.
                         ne843Dc1 1.3.6.1.4.1.10520.2.1.3.1
                             ne843Dc1Ide 1.3.6.1.4.1.10520.2.1.3.1.1 displaystring read-only
Identifier
                             ne843Dc1Des 1.3.6.1.4.1.10520.2.1.3.1.2 displaystring read-write
Description
                             ne843Dc1Typ 1.3.6.1.4.1.10520.2.1.3.1.3 displaystring read-only
Type
                             ne843Dc1Vdc 1.3.6.1.4.1.10520.2.1.3.1.4 integer32 read-only
Voltage (mV)
                             ne843Dc1Adc 1.3.6.1.4.1.10520.2.1.3.1.5 integer32 read-only
Current (Amps)
                             ne843Dc1Cap 1.3.6.1.4.1.10520.2.1.3.1.6 integer32 read-only
Total Installed Rectifier Capacity (Amps)
                             ne843Dc1Olcap 1.3.6.1.4.1.10520.2.1.3.1.7 integer32 read-only
Total On-line Rectifier Capacity (Amps)
                             ne843Dc1Trd 1.3.6.1.4.1.10520.2.1.3.1.8 integer32 read-only
Total Rectifier Drain (Amps)
                             ne843Dc1Sht 1.3.6.1.4.1.10520.2.1.3.1.9 displaystring read-write
Centralized Plant Shunt Type Values: NONE, BATTERY, LOAD
                             ne843Dc1Sha 1.3.6.1.4.1.10520.2.1.3.1.10 integer32 read-write
Centralized Plant Shunt Size (Amps)
                             ne843Dc1Stt 1.3.6.1.4.1.10520.2.1.3.1.11 displaystring read-write
State Values: FLOAT, BOOST
                             ne843Dc1Bod 1.3.6.1.4.1.10520.2.1.3.1.12 displaystring read-only
Battery On Discharge
                             ne843Dc1Rss 1.3.6.1.4.1.10520.2.1.3.1.13 integer read-write
Rectifier Restart Values: off(0), on(1) Enumeration: 'on': 1, 'off': 0.
                             ne843Dc1Rsq 1.3.6.1.4.1.10520.2.1.3.1.14 integer read-write
Rectifier Sequencing Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                             ne843Dc1Ron 1.3.6.1.4.1.10520.2.1.3.1.15 integer32 read-write
External Standby
                             ne843Dc1Rot 1.3.6.1.4.1.10520.2.1.3.1.16 integer32 read-write
All Rectifier On Threshold (mV)
                             ne843Dc1Nst 1.3.6.1.4.1.10520.2.1.3.1.17 integer32 read-only
Number of Strings
                             ne843Dc1Cps 1.3.6.1.4.1.10520.2.1.3.1.18 integer32 read-only
Cells per String
                             ne843Dc1Bty 1.3.6.1.4.1.10520.2.1.3.1.19 displaystring read-only
Battery Type
                             ne843Dc1Isd 1.3.6.1.4.1.10520.2.1.3.1.20 integer read-write
Imminent Shutdown Enable Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                             ne843Dc1Rtm 1.3.6.1.4.1.10520.2.1.3.1.21 displaystring read-only
Reserve Time
                             ne843Dc1Scap 1.3.6.1.4.1.10520.2.1.3.1.22 integer32 read-only
String Capacity (Amps)
                             ne843Dc1Mls 1.3.6.1.4.1.10520.2.1.3.1.23 integer read-write
All Shunts Monitored Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                             ne843Dc1Amj 1.3.6.1.4.1.10520.2.1.3.1.24 displaystring read-only
Auxiliary Fuse Major Value: Alarm report from AMJ1
                             ne843Dc1Vsf 1.3.6.1.4.1.10520.2.1.3.1.25 displaystring read-only
Sense/Control Fuse Value: Alarm report from VSF1
                             ne843Dc1Osa 1.3.6.1.4.1.10520.2.1.3.1.26 displaystring read-only
Open String Value: Alarm report from OSA1
                             ne843Dc1Zid 1.3.6.1.4.1.10520.2.1.3.1.27 displaystring read-only
ID Not Configured Value: Alarm report from ZID1
                             ne843Dc1Tpa 1.3.6.1.4.1.10520.2.1.3.1.28 displaystring read-only
Thermal Probe Alarm Value: Alarm report from TPA1
                             ne843Dc1Vmf 1.3.6.1.4.1.10520.2.1.3.1.29 displaystring read-only
Voltage Module Fail Value: Alarm report from VMF1
                             ne843Dc1Cma 1.3.6.1.4.1.10520.2.1.3.1.30 displaystring read-only
Minor Communication Failure Value: Alarm report from CMA1
                             ne843Dc1Mcm 1.3.6.1.4.1.10520.2.1.3.1.31 displaystring read-only
Major Communication Failure Value: Alarm report from MCM1
                             ne843Dc1Epo 1.3.6.1.4.1.10520.2.1.3.1.32 displaystring read-only
Emergency Power Off Value: Alarm report from EPO1
                             ne843Dc1Icr 1.3.6.1.4.1.10520.2.1.3.1.33 displaystring read-only
Incompatible Rectifier Value: Alarm report from ICR1
                             ne843Dc1Rfa 1.3.6.1.4.1.10520.2.1.3.1.34 displaystring read-only
Rectifier Fail Value: Alarm report from RFA1
                             ne843Dc1Acf 1.3.6.1.4.1.10520.2.1.3.1.35 displaystring read-only
AC Fail Value: Alarm report from ACF1
                             ne843Dc1Man 1.3.6.1.4.1.10520.2.1.3.1.36 displaystring read-only
Manual Off Value: Alarm report from MAN1
                             ne843Dc1Did 1.3.6.1.4.1.10520.2.1.3.1.37 displaystring read-only
ID Conflict Value: Alarm report from DID1
                             ne843Dc1Clm 1.3.6.1.4.1.10520.2.1.3.1.38 displaystring read-only
Rectifier Current Limit Value: Alarm report from CLM1
                             ne843Dc1Rfn 1.3.6.1.4.1.10520.2.1.3.1.39 displaystring read-only
Rectifier Fan Failure Value: Alarm report from RFN1
                             ne843Dc1Vla 1.3.6.1.4.1.10520.2.1.3.1.40 displaystring read-only
Very Low Voltage Value: Alarm report from VLA1
                             ne843Dc1Mfa 1.3.6.1.4.1.10520.2.1.3.1.41 displaystring read-only
Multiple Rectifier Fail Value: Alarm report from MFA1
                             ne843Dc1Rtl 1.3.6.1.4.1.10520.2.1.3.1.42 displaystring read-only
Reserve Time Low Value: Alarm report from RTL1
                             ne843Dc1Rrtl 1.3.6.1.4.1.10520.2.1.3.1.43 displaystring read-only
Real-time Reserve Time Low Value: Alarm report from RRTL1
                             ne843Dc1Rls 1.3.6.1.4.1.10520.2.1.3.1.44 displaystring read-only
Redundancy Loss Value: Alarm report from RLS1
                             ne843Dc1Mman 1.3.6.1.4.1.10520.2.1.3.1.45 displaystring read-only
Multiple Manual Off Value: Alarm report from MMAN1
                             ne843Dc1Macf 1.3.6.1.4.1.10520.2.1.3.1.46 displaystring read-only
Multiple AC Failure Value: Alarm report from MACF1
                             ne843Dc1Bda 1.3.6.1.4.1.10520.2.1.3.1.47 displaystring read-only
Battery On Discharge Value: Alarm report from BDA1
                             ne843Dc1Hva 1.3.6.1.4.1.10520.2.1.3.1.48 displaystring read-only
High Voltage Value: Alarm report from HVA1
                             ne843Dc1Hfv 1.3.6.1.4.1.10520.2.1.3.1.49 displaystring read-only
High Float Voltage Value: Alarm report from HFV1
                             ne843Dc1Bdt 1.3.6.1.4.1.10520.2.1.3.1.50 displaystring read-only
BD Duration
                             ne843Dc1Ems 1.3.6.1.4.1.10520.2.1.3.1.51 displaystring read-only
Energy Management State
                             ne843Dc1Eme 1.3.6.1.4.1.10520.2.1.3.1.52 integer read-write
Energy Management Enable Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                             ne843Dc1Emt 1.3.6.1.4.1.10520.2.1.3.1.53 integer32 read-write
Efficiency Target (%)
                             ne843Dc1Emo 1.3.6.1.4.1.10520.2.1.3.1.54 integer32 read-write
Efficiency Rectifier Turn On Threshold (%)
                             ne843Dc1Poc 1.3.6.1.4.1.10520.2.1.3.1.55 displaystring read-only
Percent of Charge (%)
                             ne843Dc1Emd 1.3.6.1.4.1.10520.2.1.3.1.56 displaystring read-only
Energy Management Disabled Value: Alarm report from EMD1
                             ne843Dc1Pfs 1.3.6.1.4.1.10520.2.1.3.1.57 displaystring read-only
Thermal Probe Fail Safe Value: Alarm report from PFS1
                             ne843Dc1Rif 1.3.6.1.4.1.10520.2.1.3.1.58 displaystring read-only
Rectifier Internal Fault Value: Alarm report from RIF1
                             ne843Dc1Lsf 1.3.6.1.4.1.10520.2.1.3.1.59 displaystring read-only
Load Share Fail Value: Alarm report from LSF1
                             ne843Dc1Emi 1.3.6.1.4.1.10520.2.1.3.1.60 integer32 read-write
Efficiency Initial Delay (Minutes)
                             ne843Dc1Emw 1.3.6.1.4.1.10520.2.1.3.1.61 integer32 read-write
Efficiency Turn Off Delay (Minutes)
                             ne843Dc1Aseq 1.3.6.1.4.1.10520.2.1.3.1.62 integer read-write
Automatic Sequencing Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                             ne843Dc1Isy 1.3.6.1.4.1.10520.2.1.3.1.63 integer32 read-write
Imminent Shutdown Delay
                             ne843Dc1Bofe 1.3.6.1.4.1.10520.2.1.3.1.64 integer read-write
Backup ORing FET Test Enable Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                             ne843Dc1Bof 1.3.6.1.4.1.10520.2.1.3.1.65 displaystring read-only
Rectifier ORing FET Fault Value: Alarm report from BOF1
                             ne843Dc1Sof 1.3.6.1.4.1.10520.2.1.3.1.66 displaystring read-only
Rectifier Shorted ORing FET Value: Alarm report from SOF1
                             ne843Dc1Der 1.3.6.1.4.1.10520.2.1.3.1.67 displaystring read-only
Rectifier Under Voltage Value: Alarm report from DER1
                             ne843Dc1Pmf 1.3.6.1.4.1.10520.2.1.3.1.68 displaystring read-only
Probe Minimum Fail Value: Alarm report from PMF1
                             ne843Dc1Faja 1.3.6.1.4.1.10520.2.1.3.1.69 displaystring read-only
Distribution Fuse A Value: Alarm report from FAJA1
                             ne843Dc1Buht 1.3.6.1.4.1.10520.2.1.3.1.70 displaystring read-only
Bus Hi Temp Value: Alarm report from BUHT1
                             ne843Dc1Buvht 1.3.6.1.4.1.10520.2.1.3.1.71 displaystring read-only
Bus Very Hi Temp Value: Alarm report from BUVHT1
                             ne843Dc1Btha 1.3.6.1.4.1.10520.2.1.3.1.72 displaystring read-only
Batt Hi Temp Value: Alarm report from BTHA1
                             ne843Dc1Btvh 1.3.6.1.4.1.10520.2.1.3.1.73 displaystring read-only
Batt Very Hi Temp Value: Alarm report from BTVH1
                             ne843Dc1Btla 1.3.6.1.4.1.10520.2.1.3.1.74 displaystring read-only
Batt Low Temp Value: Alarm report from BTLA1
                             ne843Dc1Btvl 1.3.6.1.4.1.10520.2.1.3.1.75 displaystring read-only
Batt Very Low Temp Value: Alarm report from BTVL1
                             ne843Dc1Laht 1.3.6.1.4.1.10520.2.1.3.1.76 displaystring read-only
Local Amb. Hi Temp Value: Alarm report from LAHT1
                             ne843Dc1Lalt 1.3.6.1.4.1.10520.2.1.3.1.77 displaystring read-only
Local Amb. Low Temp Value: Alarm report from LALT1
                             ne843Dc1Raht 1.3.6.1.4.1.10520.2.1.3.1.78 displaystring read-only
Remote Amb. Hi Temp Value: Alarm report from RAHT
                             ne843Dc1Ravht 1.3.6.1.4.1.10520.2.1.3.1.79 displaystring read-only
Remote Amb. Very Hi Temp Value: Alarm report from RAVHT1
                             ne843Dc1Ralt 1.3.6.1.4.1.10520.2.1.3.1.80 displaystring read-only
Remote Amb. Low Temp Value: Alarm report from RALT1
                             ne843Dc1Vlva 1.3.6.1.4.1.10520.2.1.3.1.81 displaystring read-only
VA Power Loss Value: Alarm report from VLVA1
                             ne843Dc1Vlvb 1.3.6.1.4.1.10520.2.1.3.1.82 displaystring read-only
VB Power Loss Value: Alarm report from VLBB1
                             ne843Dc1Ovla 1.3.6.1.4.1.10520.2.1.3.1.83 displaystring read-only
IA Overload Value: Alarm report from OVLA1
                             ne843Dc1Ovlb 1.3.6.1.4.1.10520.2.1.3.1.84 displaystring read-only
IB Overload Value: Alarm report from OVLB1
                             ne843Dc1Pcaux 1.3.6.1.4.1.10520.2.1.3.1.85 displaystring read-only
PIC Auxiliary Value: Alarm report from PCAUX1
                             ne843Dc1Slot 1.3.6.1.4.1.10520.2.1.3.1.86 displaystring read-only
PIC Slot Value: Alarm report from SLOT1
                             ne843Dc1Bod1 1.3.6.1.4.1.10520.2.1.3.1.87 integer read-only
Battery On Discharge Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                             ne843Dc1Bdt1 1.3.6.1.4.1.10520.2.1.3.1.88 integer32 read-only
BD Duration (Seconds)
                             ne843Dc1Poc1 1.3.6.1.4.1.10520.2.1.3.1.89 integer32 read-only
Percent of Charge (%)
                             ne843Dc1Fajb 1.3.6.1.4.1.10520.2.1.3.1.90 displaystring read-only
Distribution Fuse B Value: Alarm report from FAJB1
                             ne843Dc1Smw 1.3.6.1.4.1.10520.2.1.3.1.91 displaystring read-only
Shunt Mis-wired Value: Alarm report from SMW1
                             ne843Dc1Cca 1.3.6.1.4.1.10520.2.1.3.1.92 displaystring read-only
Circuit Assignment Value: Alarm report from CCA1
                         ne843Ps1 1.3.6.1.4.1.10520.2.1.3.2
                             ne843Ps1Ide 1.3.6.1.4.1.10520.2.1.3.2.1 displaystring read-only
Identifier
                             ne843Ps1Des 1.3.6.1.4.1.10520.2.1.3.2.2 displaystring read-write
Description
                             ne843Ps1Sid 1.3.6.1.4.1.10520.2.1.3.2.3 displaystring read-write
Site ID
                             ne843Ps1Sde 1.3.6.1.4.1.10520.2.1.3.2.4 displaystring read-write
Site Description
                             ne843Ps1Sys 1.3.6.1.4.1.10520.2.1.3.2.5 displaystring read-write
System Description
                             ne843Ps1Swv 1.3.6.1.4.1.10520.2.1.3.2.6 displaystring read-only
Software Version
                             ne843Ps1Verw 1.3.6.1.4.1.10520.2.1.3.2.7 displaystring read-only
Web Page Version
                             ne843Ps1Verb 1.3.6.1.4.1.10520.2.1.3.2.8 displaystring read-only
Boot Block Version
                             ne843Ps1Verd 1.3.6.1.4.1.10520.2.1.3.2.9 displaystring read-only
Display Version
                             ne843Ps1Dflt 1.3.6.1.4.1.10520.2.1.3.2.10 displaystring read-only
Defaults Version
                             ne843Ps1Brc 1.3.6.1.4.1.10520.2.1.3.2.11 displaystring read-only
Board Code
                             ne843Ps1Sn 1.3.6.1.4.1.10520.2.1.3.2.12 displaystring read-only
Serial Number
                             ne843Ps1Dat 1.3.6.1.4.1.10520.2.1.3.2.13 displaystring read-write
System Date
                             ne843Ps1Dtf 1.3.6.1.4.1.10520.2.1.3.2.14 displaystring read-write
Date Format Values: mm/dd/yyyy, dd/mm/yyyy, yyyy/mm/dd
                             ne843Ps1Tim 1.3.6.1.4.1.10520.2.1.3.2.15 displaystring read-write
System Time
                             ne843Ps1Tmf 1.3.6.1.4.1.10520.2.1.3.2.16 integer read-write
System Time Format Values: h12(12), h24(24) Enumeration: 'h24': 24, 'h12': 12.
                             ne843Ps1Dls 1.3.6.1.4.1.10520.2.1.3.2.17 integer read-write
Daylight Saving Values: off(0), on(1) Enumeration: 'on': 1, 'off': 0.
                             ne843Ps1Lng 1.3.6.1.4.1.10520.2.1.3.2.18 displaystring read-write
Front Panel Language Values: ENGLISH, OTHER
                             ne843Ps1Tun 1.3.6.1.4.1.10520.2.1.3.2.19 displaystring read-write
Temperature Units Values: C, F
                             ne843Ps1Cem 1.3.6.1.4.1.10520.2.1.3.2.20 integer read-write
Critical Equals Major Values: off(0), on(1) Enumeration: 'on': 1, 'off': 0.
                             ne843Ps1Fpc 1.3.6.1.4.1.10520.2.1.3.2.21 integer read-write
Front Panel Configuration Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                             ne843Ps1Rrf 1.3.6.1.4.1.10520.2.1.3.2.22 integer read-write
Remote Rectifier Off Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                             ne843Ps1Poe 1.3.6.1.4.1.10520.2.1.3.2.23 integer read-write
Power Off Enable Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                             ne843Ps1Usl 1.3.6.1.4.1.10520.2.1.3.2.24 integer read-write
Uninstall Missing Equipment Values: uninstall(1) Enumeration: 'uninstall': 1.
                             ne843Ps1Usr 1.3.6.1.4.1.10520.2.1.3.2.25 integer read-write
Enable User Accounts Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                             ne843Ps1Ptt 1.3.6.1.4.1.10520.2.1.3.2.26 displaystring read-only
Communication Port Type Values: LOCAL, MODEM
                             ne843Ps1Amt 1.3.6.1.4.1.10520.2.1.3.2.27 integer32 read-only
Ambient Temperature (C)
                             ne843Ps1Fst 1.3.6.1.4.1.10520.2.1.3.2.28 displaystring read-write
Factory Defaults
                             ne843Ps1Fstl 1.3.6.1.4.1.10520.2.1.3.2.29 displaystring read-only
Factory Defaults List
                             ne843Ps1Fpe 1.3.6.1.4.1.10520.2.1.3.2.30 integer read-write
Front Panel Pin Enable Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                             ne843Ps1Fpt 1.3.6.1.4.1.10520.2.1.3.2.31 integer32 read-write
Front Panel Pin Timeout
                             ne843Ps1Rss 1.3.6.1.4.1.10520.2.1.3.2.32 integer read-write
Restart Devices Values: restart(1) Enumeration: 'restart': 1.
                             ne843Ps1Ast 1.3.6.1.4.1.10520.2.1.3.2.33 displaystring read-only
System Alarm State
                             ne843Ps1Dss 1.3.6.1.4.1.10520.2.1.3.2.34 displaystring read-write
Daylight Saving Start mon:wk:dow:min or, mon:-1:dom:min
                             ne843Ps1Dse 1.3.6.1.4.1.10520.2.1.3.2.35 displaystring read-write
Daylight Saving End mon:wk:dow:min or, mon:-1:dom:min
                             ne843Ps1Epr 1.3.6.1.4.1.10520.2.1.3.2.36 displaystring read-only
External Password Reset Value: Alarm report from EPR1
                             ne843Ps1Pfd 1.3.6.1.4.1.10520.2.1.3.2.37 displaystring read-only
Passwords At Default Value: Alarm report from PFD1
                             ne843Ps1Exl 1.3.6.1.4.1.10520.2.1.3.2.38 displaystring read-only
Excessive Login Attempts Value: Alarm report from EXL1
                             ne843Ps1Bbl 1.3.6.1.4.1.10520.2.1.3.2.39 displaystring read-only
Memory Backup Battery Low Value: Alarm report from BBL1
                             ne843Ps1Clc 1.3.6.1.4.1.10520.2.1.3.2.40 displaystring read-only
Clock Changed Value: Alarm report from CLC1
                             ne843Ps1Stf 1.3.6.1.4.1.10520.2.1.3.2.41 displaystring read-only
Self Test Failed Value: Alarm report from STF1
                             ne843Ps1Pgi 1.3.6.1.4.1.10520.2.1.3.2.42 displaystring read-only
Program Line Invalid Value: Alarm report from PGI1
                             ne843Ps1Cch 1.3.6.1.4.1.10520.2.1.3.2.43 displaystring read-only
Configuration Changed Value: Alarm report from CCH1
                             ne843Ps1Hcl 1.3.6.1.4.1.10520.2.1.3.2.44 displaystring read-only
History Cleared Value: Alarm report from HCL1
                             ne843Ps1Ax1 1.3.6.1.4.1.10520.2.1.3.2.45 displaystring read-only
Auxiliary Event 1 Value: Alarm report from AUX1
                             ne843Ps1Ax2 1.3.6.1.4.1.10520.2.1.3.2.46 displaystring read-only
Auxiliary Event 2 Value: Alarm report from AUX2
                             ne843Ps1Ax3 1.3.6.1.4.1.10520.2.1.3.2.47 displaystring read-only
Auxiliary Event 3 Value: Alarm report from AUX3
                             ne843Ps1Ax4 1.3.6.1.4.1.10520.2.1.3.2.48 displaystring read-only
Auxiliary Event 4 Value: Alarm report from AUX4
                             ne843Ps1Ax5 1.3.6.1.4.1.10520.2.1.3.2.49 displaystring read-only
Auxiliary Event 5 Value: Alarm report from AUX5
                             ne843Ps1Ax6 1.3.6.1.4.1.10520.2.1.3.2.50 displaystring read-only
Auxiliary Event 6 Value: Alarm report from AUX6
                             ne843Ps1Fan24 1.3.6.1.4.1.10520.2.1.3.2.51 displaystring read-only
24 V Fuse Minor Value: Alarm report from FAN1
                             ne843Ps1Fan48 1.3.6.1.4.1.10520.2.1.3.2.52 displaystring read-only
48 V Fuse Minor Value: Alarm report from FAN2
                             ne843Ps1Faj24 1.3.6.1.4.1.10520.2.1.3.2.53 displaystring read-only
24 V Fuse Major Value: Alarm report from FAJ1
                             ne843Ps1Faj48 1.3.6.1.4.1.10520.2.1.3.2.54 displaystring read-only
48 V Fuse Major Value: Alarm report from FAJ2
                             ne843Ps1Accl 1.3.6.1.4.1.10520.2.1.3.2.55 displaystring read-only
Relay List
                             ne843Ps1Ledl 1.3.6.1.4.1.10520.2.1.3.2.56 displaystring read-only
LED List
                             ne843Ps1Ax7 1.3.6.1.4.1.10520.2.1.3.2.57 displaystring read-only
Auxiliary Event 7 Value: Alarm report from AUX7
                             ne843Ps1Ax8 1.3.6.1.4.1.10520.2.1.3.2.58 displaystring read-only
Auxiliary Event 8 Value: Alarm report from AUX8
                             ne843Ps1Ax9 1.3.6.1.4.1.10520.2.1.3.2.59 displaystring read-only
Auxiliary Event 9 Value: Alarm report from AUX9
                             ne843Ps1Ax10 1.3.6.1.4.1.10520.2.1.3.2.60 displaystring read-only
Auxiliary Event 10 Value: Alarm report from AUX10
                             ne843Ps1Ax11 1.3.6.1.4.1.10520.2.1.3.2.61 displaystring read-only
Auxiliary Event 11 Value: Alarm report from AUX11
                             ne843Ps1Ax12 1.3.6.1.4.1.10520.2.1.3.2.62 displaystring read-only
Auxiliary Event 12 Value: Alarm report from AUX12
                             ne843Ps1Cid 1.3.6.1.4.1.10520.2.1.3.2.63 integer read-write
Controller Assignes IDs Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                             ne843Ps1Lngl 1.3.6.1.4.1.10520.2.1.3.2.64 displaystring read-only
Available Languages
                             ne843Ps1Amtl 1.3.6.1.4.1.10520.2.1.3.2.65 displaystring read-only
Low Ambient Temperature Value: Alarm report from AMTL1
                             ne843Ps1Amth 1.3.6.1.4.1.10520.2.1.3.2.66 displaystring read-only
High Ambient Temperature Value: Alarm report from AMTH1
                             ne843Ps1Cc 1.3.6.1.4.1.10520.2.1.3.2.67 displaystring read-only
Comcode
                             ne843Ps1Clei 1.3.6.1.4.1.10520.2.1.3.2.68 displaystring read-only
CLEI Code
                             ne843Ps1Ser 1.3.6.1.4.1.10520.2.1.3.2.69 displaystring read-only
Series
                             ne843Ps1Lamt 1.3.6.1.4.1.10520.2.1.3.2.70 integer32 read-only
Lowest Ambient Temperature (C)
                             ne843Ps1Nat 1.3.6.1.4.1.10520.2.1.3.2.71 integer32 read-only
Number of Ambient Temperature Probes Present
                             ne843Ps1Blr 1.3.6.1.4.1.10520.2.1.3.2.72 displaystring read-write
Bay Lamp Relay Values: , R1, R2, R3, R4, R5, R6, R7
                             ne843Ps1Tzo 1.3.6.1.4.1.10520.2.1.3.2.73 integer32 read-write
Timezone Offset (Minutes)
                             ne843Ps1Crt 1.3.6.1.4.1.10520.2.1.3.2.74 displaystring read-only
Configuration Changed Reboot Required Value: Alarm report from CRT1
                             ne843Ps1Nhat 1.3.6.1.4.1.10520.2.1.3.2.75 integer32 read-write
Next Highest Ambient Temperature (C)
                             ne843Ps1Nal 1.3.6.1.4.1.10520.2.1.3.2.76 integer32 read-only
Number of Total Alarms Active
                             ne843Ps1Ncr 1.3.6.1.4.1.10520.2.1.3.2.77 integer32 read-only
Number of Total Critical Alarms Active
                             ne843Ps1Nmj 1.3.6.1.4.1.10520.2.1.3.2.78 integer32 read-only
Number of Total Major Alarms Active
                             ne843Ps1Nmn 1.3.6.1.4.1.10520.2.1.3.2.79 integer32 read-only
Number of Total Minor Alarms Active
                             ne843Ps1Nwa 1.3.6.1.4.1.10520.2.1.3.2.80 integer32 read-only
Number of Total Warnings Active
                             ne843Ps1Nre 1.3.6.1.4.1.10520.2.1.3.2.81 integer32 read-only
Number of Total Record Only Events Active
                             ne843Ps1Ere 1.3.6.1.4.1.10520.2.1.3.2.82 integer read-write
PCR/PMJ/PMN Enahnced Relays Enabled Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                         ne843At1 1.3.6.1.4.1.10520.2.1.3.3
                             ne843At1Ide 1.3.6.1.4.1.10520.2.1.3.3.1 displaystring read-only
Identifier
                             ne843At1Des 1.3.6.1.4.1.10520.2.1.3.3.2 displaystring read-write
Description
                             ne843At1Stt 1.3.6.1.4.1.10520.2.1.3.3.3 integer read-write
Alarm Test Active Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                             ne843At1Stg 1.3.6.1.4.1.10520.2.1.3.3.4 displaystring read-only
Stage
                             ne843At1Lte 1.3.6.1.4.1.10520.2.1.3.3.5 integer read-write
Alarm Test Enable Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                             ne843At1Dur 1.3.6.1.4.1.10520.2.1.3.3.6 integer32 read-write
Alarm Contact Duration (Seconds)
                             ne843At1Pcr 1.3.6.1.4.1.10520.2.1.3.3.7 integer read-write
Power Critical Values: no(0), yes(1) Enumeration: 'yes': 1, 'no': 0.
                             ne843At1Pmj 1.3.6.1.4.1.10520.2.1.3.3.8 integer read-write
Power Major Values: no(0), yes(1) Enumeration: 'yes': 1, 'no': 0.
                             ne843At1Pmn 1.3.6.1.4.1.10520.2.1.3.3.9 integer read-write
Power Minor Values: no(0), yes(1) Enumeration: 'yes': 1, 'no': 0.
                             ne843At1R1 1.3.6.1.4.1.10520.2.1.3.3.10 integer read-write
Test Relay 1 Values: no(0), yes(1) Enumeration: 'yes': 1, 'no': 0.
                             ne843At1R2 1.3.6.1.4.1.10520.2.1.3.3.11 integer read-write
Test Relay 2 Values: no(0), yes(1) Enumeration: 'yes': 1, 'no': 0.
                             ne843At1R3 1.3.6.1.4.1.10520.2.1.3.3.12 integer read-write
Test Relay 3 Values: no(0), yes(1) Enumeration: 'yes': 1, 'no': 0.
                             ne843At1R4 1.3.6.1.4.1.10520.2.1.3.3.13 integer read-write
Test Relay 4 Values: no(0), yes(1) Enumeration: 'yes': 1, 'no': 0.
                             ne843At1R5 1.3.6.1.4.1.10520.2.1.3.3.14 integer read-write
Test Relay 5 Values: no(0), yes(1) Enumeration: 'yes': 1, 'no': 0.
                             ne843At1R6 1.3.6.1.4.1.10520.2.1.3.3.15 integer read-write
Test Relay 6 Values: no(0), yes(1) Enumeration: 'yes': 1, 'no': 0.
                             ne843At1R7 1.3.6.1.4.1.10520.2.1.3.3.16 integer read-write
Test Relay 7 Values: no(0), yes(1) Enumeration: 'yes': 1, 'no': 0.
                             ne843At1Ets 1.3.6.1.4.1.10520.2.1.3.3.17 integer read-write
Do Email Test Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                             ne843At1Ems 1.3.6.1.4.1.10520.2.1.3.3.18 displaystring read-only
Email Test Results
                             ne843At1Bzi 1.3.6.1.4.1.10520.2.1.3.3.19 integer32 read-write
Audio Test Duration (Seconds)
                             ne843At1Bzt 1.3.6.1.4.1.10520.2.1.3.3.20 displaystring read-write
Audio Test Active Values: , LOCAL
                             ne843At1Irt 1.3.6.1.4.1.10520.2.1.3.3.21 displaystring read-write
Individual Relay Test State Values: , PCR, PMJ, PMN, R1, R2, R3, R4, R5, R6, R7
                             ne843At1Ata 1.3.6.1.4.1.10520.2.1.3.3.22 displaystring read-only
Alarm Test Active Value: Alarm report from ATA1
                             ne843At1Atb 1.3.6.1.4.1.10520.2.1.3.3.23 displaystring read-only
Alarm Test Aborted Value: Alarm report from ATB1
                             ne843At1Snt 1.3.6.1.4.1.10520.2.1.3.3.24 integer read-write
Email Test Values: start(1) Enumeration: 'start': 1.
                         ne843TrsTable 1.3.6.1.4.1.10520.2.1.3.4 no-access
Table of all Trend data
                             ne843TrsEntry 1.3.6.1.4.1.10520.2.1.3.4.1 no-access
Entry of information for one Trend
                                 ne843TrsEntryIndex 1.3.6.1.4.1.10520.2.1.3.4.1.1 integer read-only
Table Index
                                 ne843TrsEntryIde 1.3.6.1.4.1.10520.2.1.3.4.1.2 displaystring read-only
Identifier
                                 ne843TrsEntryDes 1.3.6.1.4.1.10520.2.1.3.4.1.3 displaystring read-write
Description
                                 ne843TrsEntrySrc 1.3.6.1.4.1.10520.2.1.3.4.1.4 displaystring read-write
Source
                         ne843Aco1 1.3.6.1.4.1.10520.2.1.3.5
                             ne843Aco1Ide 1.3.6.1.4.1.10520.2.1.3.5.1 displaystring read-only
Identifier
                             ne843Aco1Des 1.3.6.1.4.1.10520.2.1.3.5.2 displaystring read-write
Description
                             ne843Aco1Stt 1.3.6.1.4.1.10520.2.1.3.5.3 integer read-write
Alarm Cut-off State Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                             ne843Aco1Cst 1.3.6.1.4.1.10520.2.1.3.5.4 integer read-only
Critical Alarm Cut-off State Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                             ne843Aco1Cae 1.3.6.1.4.1.10520.2.1.3.5.5 integer read-write
Critical Alarm Cut-off Enable Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                             ne843Aco1Cto 1.3.6.1.4.1.10520.2.1.3.5.6 integer32 read-write
Critical Alarm Cut-off Timeout (Hours)
                             ne843Aco1Jst 1.3.6.1.4.1.10520.2.1.3.5.7 integer read-only
Major Alarm Cut-off State Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                             ne843Aco1Jae 1.3.6.1.4.1.10520.2.1.3.5.8 integer read-write
Major Alarm Cut-off Enable Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                             ne843Aco1Jto 1.3.6.1.4.1.10520.2.1.3.5.9 integer32 read-write
Major Alarm Cut-off Timeout (Hours)
                             ne843Aco1Nst 1.3.6.1.4.1.10520.2.1.3.5.10 integer read-only
Minor Alarm Cut-off State Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                             ne843Aco1Nae 1.3.6.1.4.1.10520.2.1.3.5.11 integer read-write
Minor Alarm Cut-off Enable Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                             ne843Aco1Nto 1.3.6.1.4.1.10520.2.1.3.5.12 integer32 read-write
Minor Alarm Cut-off Timeout (Hours)
                             ne843Aco1Lbe 1.3.6.1.4.1.10520.2.1.3.5.13 integer read-write
Local Buzzer Enable Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                             ne843Aco1Aac 1.3.6.1.4.1.10520.2.1.3.5.14 displaystring read-only
ACO Active Value: Alarm report from AAC1
                         ne843Gm1 1.3.6.1.4.1.10520.2.1.3.6
                             ne843Gm1Ide 1.3.6.1.4.1.10520.2.1.3.6.1 displaystring read-only
Identifier
                             ne843Gm1Des 1.3.6.1.4.1.10520.2.1.3.6.2 displaystring read-write
Description
                             ne843Gm1Lse 1.3.6.1.4.1.10520.2.1.3.6.3 integer read-write
Load Share Enable Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                             ne843Gm1Rme 1.3.6.1.4.1.10520.2.1.3.6.4 integer read-write
Redundancy Monitor Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                             ne843Gm1Fsd 1.3.6.1.4.1.10520.2.1.3.6.5 integer32 read-write
Float High Voltage Shutdown (mV)
                             ne843Gm1Bsd 1.3.6.1.4.1.10520.2.1.3.6.6 integer32 read-write
Boost High Voltage Shutdown (mV)
                             ne843Gm1Fsp 1.3.6.1.4.1.10520.2.1.3.6.7 integer32 read-write
Float Set Point (mV)
                             ne843Gm1Bsp 1.3.6.1.4.1.10520.2.1.3.6.8 integer32 read-write
Boost Set Point (mV)
                             ne843Gm1Fcl 1.3.6.1.4.1.10520.2.1.3.6.9 integer32 read-write
Float Current Limit (%)
                             ne843Gm1Bcl 1.3.6.1.4.1.10520.2.1.3.6.10 integer32 read-write
Boost Current Limit (%)
                             ne843Gm1Oft 1.3.6.1.4.1.10520.2.1.3.6.11 integer read-write
Or-ing FET Test Values: start(1) Enumeration: 'start': 1.
                             ne843Gm1Wie 1.3.6.1.4.1.10520.2.1.3.6.12 integer read-write
Walk-in Enable Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                             ne843Gm1Sof 1.3.6.1.4.1.10520.2.1.3.6.13 integer read-write
Shorted ORing FET Test Enable Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                             ne843Gm1Lsfe 1.3.6.1.4.1.10520.2.1.3.6.14 integer read-write
Load Share Fail Enable Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                             ne843Gm1Nro 1.3.6.1.4.1.10520.2.1.3.6.15 displaystring read-only
Number of Rectifiers On
                             ne843Gm1Lst 1.3.6.1.4.1.10520.2.1.3.6.16 integer32 read-only
Load Share Target
                             ne843Gm1Nro1 1.3.6.1.4.1.10520.2.1.3.6.17 integer32 read-only
Number of Rectifiers On
                         ne843RecTable 1.3.6.1.4.1.10520.2.1.3.7 no-access
Table of all Rectifier data
                             ne843RecEntry 1.3.6.1.4.1.10520.2.1.3.7.1 no-access
Entry of information for one Rectifier
                                 ne843RecEntryIndex 1.3.6.1.4.1.10520.2.1.3.7.1.1 integer read-only
Table Index
                                 ne843RecEntryIde 1.3.6.1.4.1.10520.2.1.3.7.1.2 displaystring read-only
Identifier
                                 ne843RecEntryDes 1.3.6.1.4.1.10520.2.1.3.7.1.3 displaystring read-write
Description
                                 ne843RecEntryTyp 1.3.6.1.4.1.10520.2.1.3.7.1.4 displaystring read-write
Type
                                 ne843RecEntrySn 1.3.6.1.4.1.10520.2.1.3.7.1.5 displaystring read-only
Serial Number
                                 ne843RecEntryAdc 1.3.6.1.4.1.10520.2.1.3.7.1.6 integer32 read-only
DC Current (Amps)
                                 ne843RecEntryVdc 1.3.6.1.4.1.10520.2.1.3.7.1.7 integer32 read-only
DC Voltage (mV)
                                 ne843RecEntryStt 1.3.6.1.4.1.10520.2.1.3.7.1.8 displaystring read-write
State Values: ON, OFF, STANDBY, VACANT
                                 ne843RecEntryCap 1.3.6.1.4.1.10520.2.1.3.7.1.9 integer32 read-only
Capacity (Amps)
                                 ne843RecEntryVac 1.3.6.1.4.1.10520.2.1.3.7.1.10 integer32 read-only
AC Voltage (Volts)
                                 ne843RecEntryAac 1.3.6.1.4.1.10520.2.1.3.7.1.11 integer32 read-only
AC Current (mA)
                                 ne843RecEntryTmp 1.3.6.1.4.1.10520.2.1.3.7.1.12 integer32 read-only
Temperature (C)
                                 ne843RecEntrySeq 1.3.6.1.4.1.10520.2.1.3.7.1.13 integer read-write
Use in Sequence Enable Values: no(0), yes(1) Enumeration: 'yes': 1, 'no': 0.
                                 ne843RecEntryRfa 1.3.6.1.4.1.10520.2.1.3.7.1.14 displaystring read-only
Rectifier Fail
                                 ne843RecEntryAcf 1.3.6.1.4.1.10520.2.1.3.7.1.15 displaystring read-only
AC Fail
                                 ne843RecEntryMan 1.3.6.1.4.1.10520.2.1.3.7.1.16 displaystring read-only
Standby or Manual Off
                                 ne843RecEntryDid 1.3.6.1.4.1.10520.2.1.3.7.1.17 displaystring read-only
ID Conflict
                                 ne843RecEntryClm 1.3.6.1.4.1.10520.2.1.3.7.1.18 displaystring read-only
Current Limit
                                 ne843RecEntryRcf 1.3.6.1.4.1.10520.2.1.3.7.1.19 displaystring read-only
Communication Failure
                                 ne843RecEntryRfn 1.3.6.1.4.1.10520.2.1.3.7.1.20 displaystring read-only
Fan Failure
                                 ne843RecEntryRif 1.3.6.1.4.1.10520.2.1.3.7.1.21 displaystring read-only
Internal Fault
                                 ne843RecEntryLsf 1.3.6.1.4.1.10520.2.1.3.7.1.22 displaystring read-only
Loadshare Failure
                                 ne843RecEntryCc 1.3.6.1.4.1.10520.2.1.3.7.1.23 displaystring read-only
Comcode
                                 ne843RecEntryClei 1.3.6.1.4.1.10520.2.1.3.7.1.24 displaystring read-only
CLEI Code
                                 ne843RecEntrySer 1.3.6.1.4.1.10520.2.1.3.7.1.25 displaystring read-only
Series
                                 ne843RecEntryVerp 1.3.6.1.4.1.10520.2.1.3.7.1.26 displaystring read-only
Primary Software Version
                                 ne843RecEntryVers 1.3.6.1.4.1.10520.2.1.3.7.1.27 displaystring read-only
Secondary Software Version
                                 ne843RecEntryLin 1.3.6.1.4.1.10520.2.1.3.7.1.28 displaystring read-only
Low Input
                                 ne843RecEntryHin 1.3.6.1.4.1.10520.2.1.3.7.1.29 displaystring read-only
High Input
                                 ne843RecEntryBof 1.3.6.1.4.1.10520.2.1.3.7.1.30 displaystring read-only
ORing FET Fault
                                 ne843RecEntrySof 1.3.6.1.4.1.10520.2.1.3.7.1.31 displaystring read-only
Shorted ORing FET
                                 ne843RecEntryDer 1.3.6.1.4.1.10520.2.1.3.7.1.32 displaystring read-only
Under Voltage
                                 ne843RecEntryEcap 1.3.6.1.4.1.10520.2.1.3.7.1.33 integer32 read-only
ECO Capacity (Amps)
                                 ne843RecEntryEmod 1.3.6.1.4.1.10520.2.1.3.7.1.34 integer32 read-only
ECO Mode
                                 ne843RecEntryMppt 1.3.6.1.4.1.10520.2.1.3.7.1.35 integer32 read-only
ECO MPPT
                                 ne843RecEntryRtm 1.3.6.1.4.1.10520.2.1.3.7.1.36 integer32 read-only
Run Time
                                 ne843RecEntryVan 1.3.6.1.4.1.10520.2.1.3.7.1.37 integer32 read-only
Anode Voltage
                                 ne843RecEntryVac1 1.3.6.1.4.1.10520.2.1.3.7.1.38 integer32 read-only
AC Voltage (Volts) Phase 1
                                 ne843RecEntryAac1 1.3.6.1.4.1.10520.2.1.3.7.1.39 integer32 read-only
AC Current (mA) Phase 1
                                 ne843RecEntryVac2 1.3.6.1.4.1.10520.2.1.3.7.1.40 integer32 read-only
AC Voltage (Volts) Phase 2
                                 ne843RecEntryAac2 1.3.6.1.4.1.10520.2.1.3.7.1.41 integer32 read-only
AC Current (mA) Phase 2
                                 ne843RecEntryVac3 1.3.6.1.4.1.10520.2.1.3.7.1.42 integer32 read-only
AC Voltage (Volts) Phase 3
                                 ne843RecEntryAac3 1.3.6.1.4.1.10520.2.1.3.7.1.43 integer32 read-only
AC Current (mA) Phase 3
                                 ne843RecEntryRfa1 1.3.6.1.4.1.10520.2.1.3.7.1.44 integer read-only
Rectifier Fail Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                                 ne843RecEntryAcf1 1.3.6.1.4.1.10520.2.1.3.7.1.45 integer read-only
AC Fail Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                                 ne843RecEntryMan1 1.3.6.1.4.1.10520.2.1.3.7.1.46 integer read-only
Standby or Manual Off Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                                 ne843RecEntryDid1 1.3.6.1.4.1.10520.2.1.3.7.1.47 integer read-only
ID Conflict Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                                 ne843RecEntryClm1 1.3.6.1.4.1.10520.2.1.3.7.1.48 integer read-only
Current Limit Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                                 ne843RecEntryRcf1 1.3.6.1.4.1.10520.2.1.3.7.1.49 integer read-only
Communication Failure Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                                 ne843RecEntryRfn1 1.3.6.1.4.1.10520.2.1.3.7.1.50 integer read-only
Fan Failure Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                                 ne843RecEntryRif1 1.3.6.1.4.1.10520.2.1.3.7.1.51 integer read-only
Internal Fault Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                                 ne843RecEntryLsf1 1.3.6.1.4.1.10520.2.1.3.7.1.52 integer read-only
Loadshare Failure Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                                 ne843RecEntryLin1 1.3.6.1.4.1.10520.2.1.3.7.1.53 integer read-only
Low Input Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                                 ne843RecEntryHin1 1.3.6.1.4.1.10520.2.1.3.7.1.54 integer read-only
High Input Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                                 ne843RecEntryBof1 1.3.6.1.4.1.10520.2.1.3.7.1.55 integer read-only
ORing FET Fault Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                                 ne843RecEntrySof1 1.3.6.1.4.1.10520.2.1.3.7.1.56 integer read-only
Shorted ORing FET Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                                 ne843RecEntryDer1 1.3.6.1.4.1.10520.2.1.3.7.1.57 integer read-only
Under Voltage Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                         ne843Cp1 1.3.6.1.4.1.10520.2.1.3.8
                             ne843Cp1Ide 1.3.6.1.4.1.10520.2.1.3.8.1 displaystring read-only
Identifier
                             ne843Cp1Des 1.3.6.1.4.1.10520.2.1.3.8.2 displaystring read-write
Description
                             ne843Cp1Typ 1.3.6.1.4.1.10520.2.1.3.8.3 displaystring read-only
Type
                             ne843Cp1Vdc 1.3.6.1.4.1.10520.2.1.3.8.4 integer32 read-only
DC Voltage (mV)
                             ne843Cp1Adc 1.3.6.1.4.1.10520.2.1.3.8.5 integer32 read-only
DC Current (Amps)
                             ne843Cp1Cap 1.3.6.1.4.1.10520.2.1.3.8.6 integer32 read-only
Capacity (Amps)
                             ne843Cp1Olcap 1.3.6.1.4.1.10520.2.1.3.8.7 integer32 read-only
On Line Capacity (Amps)
                             ne843Cp1Vsp 1.3.6.1.4.1.10520.2.1.3.8.8 integer32 read-write
Voltage Set Point (mV)
                             ne843Cp1Vsd 1.3.6.1.4.1.10520.2.1.3.8.9 integer32 read-write
Internal High Voltage Shutdown (mV)
                             ne843Cp1Clm 1.3.6.1.4.1.10520.2.1.3.8.10 integer32 read-write
Current Limit (%)
                             ne843Cp1Dth 1.3.6.1.4.1.10520.2.1.3.8.11 integer32 read-write
Low Voltage Disconnect (mV)
                             ne843Cp1Rth 1.3.6.1.4.1.10520.2.1.3.8.12 integer32 read-write
Low Voltage Reconnect (mV)
                             ne843Cp1Lvd 1.3.6.1.4.1.10520.2.1.3.8.13 integer read-write
Low Voltage Disconnect Enable Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                             ne843Cp1Rss 1.3.6.1.4.1.10520.2.1.3.8.14 integer read-write
Converter Restart Values: off(0), on(1) Enumeration: 'on': 1, 'off': 0.
                             ne843Cp1Rme 1.3.6.1.4.1.10520.2.1.3.8.15 integer read-write
Redundancy Monitor Enable Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                             ne843Cp1Rof 1.3.6.1.4.1.10520.2.1.3.8.16 integer read-write
Remote Standby Enable Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                             ne843Cp1Cfa 1.3.6.1.4.1.10520.2.1.3.8.17 displaystring read-only
Converter Fail Value: Alarm report from CFA1
                             ne843Cp1Cfn 1.3.6.1.4.1.10520.2.1.3.8.18 displaystring read-only
Converter Fan Minor Value: Alarm report from CFN1
                             ne843Cp1Cfj 1.3.6.1.4.1.10520.2.1.3.8.19 displaystring read-only
Converter Fan Major Value: Alarm report from CFJ1
                             ne843Cp1Dfa 1.3.6.1.4.1.10520.2.1.3.8.20 displaystring read-only
Distribution Fail Value: Alarm report from CDFA1
                             ne843Cp1Did 1.3.6.1.4.1.10520.2.1.3.8.21 displaystring read-only
ID Conflict Value: Alarm report from CDID1
                             ne843Cp1Icc 1.3.6.1.4.1.10520.2.1.3.8.22 displaystring read-only
Incompatible Converter Alarm Value: Alarm report from ICC1
                             ne843Cp1Mfa 1.3.6.1.4.1.10520.2.1.3.8.23 displaystring read-only
Multiple Converter Fail Value: Alarm report from CMFA1
                             ne843Cp1Hva 1.3.6.1.4.1.10520.2.1.3.8.24 displaystring read-only
Converter High Voltage Major Value: Alarm report from CHVA1
                             ne843Cp1Hfv 1.3.6.1.4.1.10520.2.1.3.8.25 displaystring read-only
Converter High Voltage Minor Value: Alarm report from CHFV1
                             ne843Cp1Vla 1.3.6.1.4.1.10520.2.1.3.8.26 displaystring read-only
Converter Very Low Voltage Value: Alarm report from CVLA
                             ne843Cp1Rl 1.3.6.1.4.1.10520.2.1.3.8.27 displaystring read-only
Converter Redundancy Loss Value: Alarm report from CRL
                             ne843Cp1Cin 1.3.6.1.4.1.10520.2.1.3.8.28 displaystring read-only
Converter Input Fail Value: Alarm report from CIN1
                         ne843DccTable 1.3.6.1.4.1.10520.2.1.3.9 no-access
Table of all Converter data
                             ne843DccEntry 1.3.6.1.4.1.10520.2.1.3.9.1 no-access
Entry of information for one Converter
                                 ne843DccEntryIndex 1.3.6.1.4.1.10520.2.1.3.9.1.1 integer read-only
Table Index
                                 ne843DccEntryIde 1.3.6.1.4.1.10520.2.1.3.9.1.2 displaystring read-only
Identifier
                                 ne843DccEntryDes 1.3.6.1.4.1.10520.2.1.3.9.1.3 displaystring read-write
Description
                                 ne843DccEntryTyp 1.3.6.1.4.1.10520.2.1.3.9.1.4 displaystring read-only
Type
                                 ne843DccEntrySn 1.3.6.1.4.1.10520.2.1.3.9.1.5 displaystring read-only
Serial Number
                                 ne843DccEntryAdc 1.3.6.1.4.1.10520.2.1.3.9.1.6 integer32 read-only
DC Current (Amps)
                                 ne843DccEntryCap 1.3.6.1.4.1.10520.2.1.3.9.1.7 integer32 read-only
Capacity (Amps)
                                 ne843DccEntryStt 1.3.6.1.4.1.10520.2.1.3.9.1.8 displaystring read-write
State Values: ON, OFF, STANDBY, VACANT
                                 ne843DccEntryCfa 1.3.6.1.4.1.10520.2.1.3.9.1.9 displaystring read-only
Converter Fail
                                 ne843DccEntryDfa 1.3.6.1.4.1.10520.2.1.3.9.1.10 displaystring read-only
Distribution Fuse Fail
                                 ne843DccEntryDid 1.3.6.1.4.1.10520.2.1.3.9.1.11 displaystring read-only
ID Conflict
                                 ne843DccEntryCcf 1.3.6.1.4.1.10520.2.1.3.9.1.12 displaystring read-only
Communication Failure
                                 ne843DccEntryCfn 1.3.6.1.4.1.10520.2.1.3.9.1.13 displaystring read-only
Fan Failure
                                 ne843DccEntryCfa1 1.3.6.1.4.1.10520.2.1.3.9.1.14 integer read-only
Converter Fail Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                                 ne843DccEntryDfa1 1.3.6.1.4.1.10520.2.1.3.9.1.15 integer read-only
Distribution Fuse Fail Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                                 ne843DccEntryDid1 1.3.6.1.4.1.10520.2.1.3.9.1.16 integer read-only
ID Conflict Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                                 ne843DccEntryCcf1 1.3.6.1.4.1.10520.2.1.3.9.1.17 integer read-only
Communication Failure Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                                 ne843DccEntryCfn1 1.3.6.1.4.1.10520.2.1.3.9.1.18 integer read-only
Fan Failure Rev Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                         ne843Bs1 1.3.6.1.4.1.10520.2.1.3.10
                               ne843Bs1Ide 1.3.6.1.4.1.10520.2.1.3.10.1 displaystring read-only
Identifier
                               ne843Bs1Des 1.3.6.1.4.1.10520.2.1.3.10.2 displaystring read-write
Description
                               ne843Bs1Stt 1.3.6.1.4.1.10520.2.1.3.10.3 displaystring read-only
State Values: QRCT, MANUAL, BTP, TIMED AUTO, OFF
                               ne843Bs1Atm 1.3.6.1.4.1.10520.2.1.3.10.4 displaystring read-write
Auto Mode Values: OFF, QRCT, TIMED
                               ne843Bs1Tmd 1.3.6.1.4.1.10520.2.1.3.10.5 integer32 read-write
Timed Manual Duration (Hours)
                               ne843Bs1Amf 1.3.6.1.4.1.10520.2.1.3.10.6 integer32 read-write
Auto Multiplication Factor
                               ne843Bs1Cta 1.3.6.1.4.1.10520.2.1.3.10.7 integer32 read-write
Current Terminated Current Threshold
                         ne843Sc1 1.3.6.1.4.1.10520.2.1.3.11
                               ne843Sc1Ide 1.3.6.1.4.1.10520.2.1.3.11.1 displaystring read-only
Identifier
                               ne843Sc1Des 1.3.6.1.4.1.10520.2.1.3.11.2 displaystring read-write
Description
                               ne843Sc1Stt 1.3.6.1.4.1.10520.2.1.3.11.3 integer read-write
State Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                               ne843Sc1Rve 1.3.6.1.4.1.10520.2.1.3.11.4 integer read-write
Raise Voltage Enable Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                               ne843Sc1Ltt 1.3.6.1.4.1.10520.2.1.3.11.5 integer32 read-write
Lower Temperature Threshold (C)
                               ne843Sc1Ntt 1.3.6.1.4.1.10520.2.1.3.11.6 integer32 read-write
Nominal Temperature Threshold (C)
                               ne843Sc1Utt 1.3.6.1.4.1.10520.2.1.3.11.7 integer32 read-write
Upper Temperature Threshold (C)
                               ne843Sc1Spt 1.3.6.1.4.1.10520.2.1.3.11.8 integer32 read-write
Step Temperature (C)
                               ne843Sc1Lsp 1.3.6.1.4.1.10520.2.1.3.11.9 integer32 read-write
Lower Temperature Slope/Cell (mV/C)
                               ne843Sc1Usp 1.3.6.1.4.1.10520.2.1.3.11.10 integer32 read-write
Upper Temperature Slope/Cell (mV/C)
                               ne843Sc1Fse 1.3.6.1.4.1.10520.2.1.3.11.11 integer read-write
Probe Fail-Safe Enable Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                         ne843BtdTable 1.3.6.1.4.1.10520.2.1.3.12 no-access
Table of all Battery Type Definition data
                               ne843BtdEntry 1.3.6.1.4.1.10520.2.1.3.12.1 no-access
Entry of information for one Battery Type Definition
                                   ne843BtdEntryIndex 1.3.6.1.4.1.10520.2.1.3.12.1.1 integer read-only
Table Index
                                   ne843BtdEntryIde 1.3.6.1.4.1.10520.2.1.3.12.1.2 displaystring read-only
Identifier
                                   ne843BtdEntryDes 1.3.6.1.4.1.10520.2.1.3.12.1.3 displaystring read-write
Description
                                   ne843BtdEntryBty 1.3.6.1.4.1.10520.2.1.3.12.1.4 displaystring read-write
Battery Type
                                   ne843BtdEntryBtc 1.3.6.1.4.1.10520.2.1.3.12.1.5 displaystring read-write
Battery Class Values: FLOODED, SEALED, NICD, LI_LMP, SODIUM
                                   ne843BtdEntryCap 1.3.6.1.4.1.10520.2.1.3.12.1.6 integer32 read-write
Capacity (Amps)
                         ne843Br1 1.3.6.1.4.1.10520.2.1.3.13
                               ne843Br1Ide 1.3.6.1.4.1.10520.2.1.3.13.1 displaystring read-only
Identifier
                               ne843Br1Des 1.3.6.1.4.1.10520.2.1.3.13.2 displaystring read-write
Description
                               ne843Br1Adc 1.3.6.1.4.1.10520.2.1.3.13.3 integer32 read-only
Total Battery Current (Amps)
                               ne843Br1Hbt 1.3.6.1.4.1.10520.2.1.3.13.4 integer32 read-only
Highest Battery Temperature (C)
                               ne843Br1Cap 1.3.6.1.4.1.10520.2.1.3.13.5 integer32 read-only
Installed Battery Capacity (Amps)
                               ne843Br1Olcap 1.3.6.1.4.1.10520.2.1.3.13.6 integer32 read-only
On-line Battery Capacity (Amps)
                               ne843Br1Btr 1.3.6.1.4.1.10520.2.1.3.13.7 displaystring read-only
Battery Test Results
                               ne843Br1Tth 1.3.6.1.4.1.10520.2.1.3.13.8 integer32 read-write
High Temperature Threshold (C)
                               ne843Br1Cle 1.3.6.1.4.1.10520.2.1.3.13.9 integer read-write
Current Limit Enable Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                               ne843Br1Clt 1.3.6.1.4.1.10520.2.1.3.13.10 integer32 read-write
Current Limit Threshold (Amps)
                               ne843Br1Cev 1.3.6.1.4.1.10520.2.1.3.13.11 integer32 read-write
End Volts per Cell (mV)
                               ne843Br1Bts 1.3.6.1.4.1.10520.2.1.3.13.12 integer read-write
Battery Test State Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                               ne843Br1Mtt 1.3.6.1.4.1.10520.2.1.3.13.13 displaystring read-write
Manual Test Type Values: DISABLE, 20%, TIMED
                               ne843Br1Tev 1.3.6.1.4.1.10520.2.1.3.13.14 integer32 read-write
Manual Test Alarm Voltage (mV)
                               ne843Br1Tmd 1.3.6.1.4.1.10520.2.1.3.13.15 integer32 read-write
Manual Test Duration (Hours x 1000)
                               ne843Br1Bte 1.3.6.1.4.1.10520.2.1.3.13.16 displaystring read-write
Automatic Test Type Values: DISABLE, 20%, TIMED
                               ne843Br1Btv 1.3.6.1.4.1.10520.2.1.3.13.17 integer32 read-write
Battery Test Rectifier Voltage (mV)
                               ne843Br1Ath 1.3.6.1.4.1.10520.2.1.3.13.18 integer32 read-write
Auto Test Hour
                               ne843Br1Tin 1.3.6.1.4.1.10520.2.1.3.13.19 integer32 read-write
Auto Test Interval (Months)
                               ne843Br1Atw 1.3.6.1.4.1.10520.2.1.3.13.20 integer32 read-write
Auto Test Minimum wait after BD (Hours)
                               ne843Br1Atd 1.3.6.1.4.1.10520.2.1.3.13.21 displaystring read-write
Auto Test Date
                               ne843Br1Nvm 1.3.6.1.4.1.10520.2.1.3.13.22 integer32 read-only
Number of Mid-cell V Present
                               ne843Br1Ntm 1.3.6.1.4.1.10520.2.1.3.13.23 integer32 read-only
Number of Temperature Probes Present
                               ne843Br1Scd 1.3.6.1.4.1.10520.2.1.3.13.24 integer read-only
Battery Voltage Imbalance Detection Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                               ne843Br1Scv 1.3.6.1.4.1.10520.2.1.3.13.25 integer32 read-write
Battery Imbalance Threshold (mV)
                               ne843Br1Bta 1.3.6.1.4.1.10520.2.1.3.13.26 displaystring read-only
Battery Test Active Value: Alarm report from BTA1
                               ne843Br1Bfa 1.3.6.1.4.1.10520.2.1.3.13.27 displaystring read-only
Battery Test Failed Value: Alarm report from BFA1
                               ne843Br1Scda 1.3.6.1.4.1.10520.2.1.3.13.28 displaystring read-only
Shorted Cell Detected Value: Alarm report from SCD1
                               ne843Br1Isda 1.3.6.1.4.1.10520.2.1.3.13.29 displaystring read-only
Imminent Shutdown Value: Alarm report from ISD1
                               ne843Br1Mdp 1.3.6.1.4.1.10520.2.1.3.13.30 displaystring read-only
Voltage Duplicate ID Value: Alarm report from MDP1
                               ne843Br1Mzd 1.3.6.1.4.1.10520.2.1.3.13.31 displaystring read-only
Voltage ID Not Configured Value: Alarm report from MZD1
                               ne843Br1Btha 1.3.6.1.4.1.10520.2.1.3.13.32 displaystring read-only
High Battery Temperature Value: Alarm report from BTHA1
                               ne843Br1Lbt 1.3.6.1.4.1.10520.2.1.3.13.33 integer32 read-only
Lowest Battery Temperature (C)
                               ne843Br1Btla 1.3.6.1.4.1.10520.2.1.3.13.34 displaystring read-only
Low Battery Temperature Value: Alarm report from BTLA1
                               ne843Br1Btvh 1.3.6.1.4.1.10520.2.1.3.13.35 displaystring read-only
Very High Battery Temperature Value: Alarm report from BTVH1
                               ne843Br1Btvl 1.3.6.1.4.1.10520.2.1.3.13.36 displaystring read-only
Very Low Battery Temperature Value: Alarm report from BTVL1
                               ne843Br1Rba 1.3.6.1.4.1.10520.2.1.3.13.37 displaystring read-only
Reverse Battery Value: Alarm report from RBA1
                         ne843CntTable 1.3.6.1.4.1.10520.2.1.3.14 no-access
Table of all Contactor data
                               ne843CntEntry 1.3.6.1.4.1.10520.2.1.3.14.1 no-access
Entry of information for one Contactor
                                   ne843CntEntryIndex 1.3.6.1.4.1.10520.2.1.3.14.1.1 integer read-only
Table Index
                                   ne843CntEntryIde 1.3.6.1.4.1.10520.2.1.3.14.1.2 displaystring read-only
Identifier
                                   ne843CntEntryDes 1.3.6.1.4.1.10520.2.1.3.14.1.3 displaystring read-write
Description
                                   ne843CntEntryStt 1.3.6.1.4.1.10520.2.1.3.14.1.4 displaystring read-write
Status Values: NONE, DISCON, CONNECT, FAILED
                                   ne843CntEntryEna 1.3.6.1.4.1.10520.2.1.3.14.1.5 integer read-write
Control Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                                   ne843CntEntryDth 1.3.6.1.4.1.10520.2.1.3.14.1.6 integer32 read-write
Disconnect Threshold (mV)
                                   ne843CntEntryDdy 1.3.6.1.4.1.10520.2.1.3.14.1.7 displaystring read-write
Disconnect Delay
                                   ne843CntEntryDam 1.3.6.1.4.1.10520.2.1.3.14.1.8 integer read-write
Disconnect Automode Values: none(0), voltage(1), voltageAndTime(2), adaptive(3), temperature(4), voltageandtemperature(5), voltageandtimeandtemperature(6), adaptiveandtemperature(7) Enumeration: 'none': 0, 'voltageAndTime': 2, 'temperature': 4, 'voltageandtemperature': 5, 'voltageandtimeandtemperature': 6, 'adaptiveandtemperature': 7, 'voltage': 1, 'adaptive': 3.
                                   ne843CntEntryDtm 1.3.6.1.4.1.10520.2.1.3.14.1.9 displaystring read-only
Disconnect Time Remaining
                                   ne843CntEntryRth 1.3.6.1.4.1.10520.2.1.3.14.1.10 integer32 read-write
Reconnect Threshold (mV)
                                   ne843CntEntryRdy 1.3.6.1.4.1.10520.2.1.3.14.1.11 displaystring read-write
Reconnect Delay
                                   ne843CntEntryRam 1.3.6.1.4.1.10520.2.1.3.14.1.12 integer read-write
Reconnect Automode Values: none(0), voltage(1), voltageAndTime(2), adaptive(3), temperature(4), voltageandtemperature(5), voltageandtimeandtemperature(6), adaptiveandtemperature(7) Enumeration: 'none': 0, 'voltageAndTime': 2, 'temperature': 4, 'voltageandtemperature': 5, 'voltageandtimeandtemperature': 6, 'adaptiveandtemperature': 7, 'voltage': 1, 'adaptive': 3.
                                   ne843CntEntryRtm 1.3.6.1.4.1.10520.2.1.3.14.1.13 displaystring read-only
Reconnect Time Remaining
                                   ne843CntEntryCno 1.3.6.1.4.1.10520.2.1.3.14.1.14 displaystring read-only
Contactor Open
                                   ne843CntEntryCnf 1.3.6.1.4.1.10520.2.1.3.14.1.15 displaystring read-only
Contactor Failed
                                   ne843CntEntryDvx 1.3.6.1.4.1.10520.2.1.3.14.1.16 integer32 read-write
VMax in Adaptive Mode (mV)
                                   ne843CntEntryDin 1.3.6.1.4.1.10520.2.1.3.14.1.17 integer32 read-write
IMin in Adaptive Mode (mA)
                                   ne843CntEntryDix 1.3.6.1.4.1.10520.2.1.3.14.1.18 integer32 read-write
IMax in Adaptive Mode (mA)
                                   ne843CntEntryDvt 1.3.6.1.4.1.10520.2.1.3.14.1.19 integer32 read-only
Calculated Disconnect Voltage (mV)
                                   ne843CntEntryDtd 1.3.6.1.4.1.10520.2.1.3.14.1.20 displaystring read-write
Disconnect Temperature Delay
                                   ne843CntEntryDtp 1.3.6.1.4.1.10520.2.1.3.14.1.21 integer32 read-write
Disconnect Temperature
                                   ne843CntEntryRtd 1.3.6.1.4.1.10520.2.1.3.14.1.22 displaystring read-write
Reconnect Temperature Delay
                                   ne843CntEntryRtp 1.3.6.1.4.1.10520.2.1.3.14.1.23 integer32 read-write
Reconnect Temperature
                         ne843DcnTable 1.3.6.1.4.1.10520.2.1.3.15 no-access
Table of all Distribution Contactor Interface data
                               ne843DcnEntry 1.3.6.1.4.1.10520.2.1.3.15.1 no-access
Entry of information for one Distribution Contactor Interface
                                   ne843DcnEntryIndex 1.3.6.1.4.1.10520.2.1.3.15.1.1 integer read-only
Table Index
                                   ne843DcnEntryIde 1.3.6.1.4.1.10520.2.1.3.15.1.2 displaystring read-only
Identifier
                                   ne843DcnEntryDes 1.3.6.1.4.1.10520.2.1.3.15.1.3 displaystring read-write
Description
                                   ne843DcnEntryStt 1.3.6.1.4.1.10520.2.1.3.15.1.4 displaystring read-only
State Values: NONE, MISSING, PRESENT, OPEN, CLOSED
                                   ne843DcnEntryTyp 1.3.6.1.4.1.10520.2.1.3.15.1.5 displaystring read-write
Contactor Interface Type Values: NONE, CN1, CN2, CN3, CN4
                                   ne843DcnEntrySn 1.3.6.1.4.1.10520.2.1.3.15.1.6 displaystring read-only
Serial Number
                                   ne843DcnEntryBrc 1.3.6.1.4.1.10520.2.1.3.15.1.7 displaystring read-only
Board Code
                         ne843DcmTable 1.3.6.1.4.1.10520.2.1.3.16 no-access
Table of all Distribution Current Monitor data
                               ne843DcmEntry 1.3.6.1.4.1.10520.2.1.3.16.1 no-access
Entry of information for one Distribution Current Monitor
                                   ne843DcmEntryIndex 1.3.6.1.4.1.10520.2.1.3.16.1.1 integer read-only
Table Index
                                   ne843DcmEntryIde 1.3.6.1.4.1.10520.2.1.3.16.1.2 displaystring read-only
Identifier
                                   ne843DcmEntryDes 1.3.6.1.4.1.10520.2.1.3.16.1.3 displaystring read-write
Description
                                   ne843DcmEntryStt 1.3.6.1.4.1.10520.2.1.3.16.1.4 displaystring read-only
State Values: NONE, MISSING, PRESENT
                                   ne843DcmEntryTyp 1.3.6.1.4.1.10520.2.1.3.16.1.5 displaystring read-write
Shunt Type Values: NONE, LOAD, BATTERY
                                   ne843DcmEntryVal 1.3.6.1.4.1.10520.2.1.3.16.1.6 integer32 read-only
Reading (mA)
                                   ne843DcmEntrySha 1.3.6.1.4.1.10520.2.1.3.16.1.7 integer32 read-write
Shunt Rating (Amps)
                                   ne843DcmEntrySn 1.3.6.1.4.1.10520.2.1.3.16.1.8 displaystring read-only
Serial Number
                                   ne843DcmEntryBrc 1.3.6.1.4.1.10520.2.1.3.16.1.9 displaystring read-only
Board Code
                                   ne843DcmEntryKwh 1.3.6.1.4.1.10520.2.1.3.16.1.10 displaystring read-write
Kilo Watt Hours (kWh)
                         ne843UdeTable 1.3.6.1.4.1.10520.2.1.3.17 no-access
Table of all User Defined Event data
                               ne843UdeEntry 1.3.6.1.4.1.10520.2.1.3.17.1 no-access
Entry of information for one User Defined Event
                                   ne843UdeEntryIndex 1.3.6.1.4.1.10520.2.1.3.17.1.1 integer read-only
Table Index
                                   ne843UdeEntryIde 1.3.6.1.4.1.10520.2.1.3.17.1.2 displaystring read-only
Identifier
                                   ne843UdeEntryDes 1.3.6.1.4.1.10520.2.1.3.17.1.3 displaystring read-write
Description
                                   ne843UdeEntryFds 1.3.6.1.4.1.10520.2.1.3.17.1.4 displaystring read-write
Front Panel Description
                                   ne843UdeEntryAst 1.3.6.1.4.1.10520.2.1.3.17.1.5 displaystring read-only
Alarm State
                                   ne843UdeEntrySev 1.3.6.1.4.1.10520.2.1.3.17.1.6 displaystring read-write
Severity Values: CRIT, MAJ, MIN, WRN, RO
                                   ne843UdeEntryPrg 1.3.6.1.4.1.10520.2.1.3.17.1.7 displaystring read-write
Program Line
                                   ne843UdeEntryDur 1.3.6.1.4.1.10520.2.1.3.17.1.8 displaystring read-write
Minimum Duration
                                   ne843UdeEntryLed 1.3.6.1.4.1.10520.2.1.3.17.1.9 displaystring read-write
LED Values: BD, AC, DC,
                                   ne843UdeEntryLat 1.3.6.1.4.1.10520.2.1.3.17.1.10 integer read-write
Latched Values: no(0), yes(1) Enumeration: 'yes': 1, 'no': 0.
                                   ne843UdeEntryAcc 1.3.6.1.4.1.10520.2.1.3.17.1.11 displaystring read-write
Contact Closure Values: , R1, R2, R3, R4, R5, R6, R7
                                   ne843UdeEntryDly 1.3.6.1.4.1.10520.2.1.3.17.1.12 integer32 read-write
Notify Delay (Seconds)
                                   ne843UdeEntryNoo 1.3.6.1.4.1.10520.2.1.3.17.1.13 integer read-write
Notify on Occur Values: no(0), yes(1) Enumeration: 'yes': 1, 'no': 0.
                                   ne843UdeEntryNor 1.3.6.1.4.1.10520.2.1.3.17.1.14 integer read-write
Notify on Retire Values: no(0), yes(1) Enumeration: 'yes': 1, 'no': 0.
                                   ne843UdeEntryNag 1.3.6.1.4.1.10520.2.1.3.17.1.15 integer read-write
NAG on Occur Values: no(0), yes(1) Enumeration: 'yes': 1, 'no': 0.
                                   ne843UdeEntryDst 1.3.6.1.4.1.10520.2.1.3.17.1.16 displaystring read-write
Notify Destination
                                   ne843UdeEntryAst1 1.3.6.1.4.1.10520.2.1.3.17.1.17 integer read-only
Alarm State Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                         ne843Cm1 1.3.6.1.4.1.10520.2.1.3.18
                               ne843Cm1Ide 1.3.6.1.4.1.10520.2.1.3.18.1 displaystring read-only
Identifier
                               ne843Cm1Des 1.3.6.1.4.1.10520.2.1.3.18.2 displaystring read-write
Description
                               ne843Cm1Ngi 1.3.6.1.4.1.10520.2.1.3.18.3 integer32 read-write
Nag Interval
                               ne843Cm1Cof 1.3.6.1.4.1.10520.2.1.3.18.4 displaystring read-only
Queue Overflow Value: Alarm report from COF1
                               ne843Cm1Cor 1.3.6.1.4.1.10520.2.1.3.18.5 displaystring read-only
Number Did Not Respond Value: Alarm report from COR1
                               ne843Cm1Nnc 1.3.6.1.4.1.10520.2.1.3.18.6 displaystring read-only
Number Not Configured Value: Alarm report from NNC1
                         ne843CopTable 1.3.6.1.4.1.10520.2.1.3.19 no-access
Table of all Call Out Phone Number data
                               ne843CopEntry 1.3.6.1.4.1.10520.2.1.3.19.1 no-access
Entry of information for one Call Out Phone Number
                                   ne843CopEntryIndex 1.3.6.1.4.1.10520.2.1.3.19.1.1 integer read-only
Table Index
                                   ne843CopEntryIde 1.3.6.1.4.1.10520.2.1.3.19.1.2 displaystring read-only
Identifier
                                   ne843CopEntryDes 1.3.6.1.4.1.10520.2.1.3.19.1.3 displaystring read-write
Description
                                   ne843CopEntryTyp 1.3.6.1.4.1.10520.2.1.3.19.1.4 displaystring read-write
Type Values: DATA, PAGER
                                   ne843CopEntryPhn 1.3.6.1.4.1.10520.2.1.3.19.1.5 displaystring read-write
Phone Number
                                   ne843CopEntryBdr 1.3.6.1.4.1.10520.2.1.3.19.1.6 integer read-write
Connect Baudrate Values: b300(300), b1200(1200), b2400(2400), b4800(4800), b9600(9600), b19200(19200) Enumeration: 'b9600': 9600, 'b1200': 1200, 'b2400': 2400, 'b19200': 19200, 'b300': 300, 'b4800': 4800.
                                   ne843CopEntryDbt 1.3.6.1.4.1.10520.2.1.3.19.1.7 integer read-write
Data Bits Values: d7(7), d8(8) Enumeration: 'd7': 7, 'd8': 8.
                                   ne843CopEntryPry 1.3.6.1.4.1.10520.2.1.3.19.1.8 displaystring read-write
Parity Values: O, E, N
                                   ne843CopEntrySbt 1.3.6.1.4.1.10520.2.1.3.19.1.9 integer read-write
Stop Bits Values: s1(1), s2(2) Enumeration: 's2': 2, 's1': 1.
                                   ne843CopEntryDly 1.3.6.1.4.1.10520.2.1.3.19.1.10 integer32 read-write
Pager ID Delay
                                   ne843CopEntryPgr 1.3.6.1.4.1.10520.2.1.3.19.1.11 displaystring read-write
Pager ID
                                   ne843CopEntryMsg 1.3.6.1.4.1.10520.2.1.3.19.1.12 displaystring read-write
Pager Message
                         ne843CoeTable 1.3.6.1.4.1.10520.2.1.3.20 no-access
Table of all Email Address data
                               ne843CoeEntry 1.3.6.1.4.1.10520.2.1.3.20.1 no-access
Entry of information for one Email Address
                                   ne843CoeEntryIndex 1.3.6.1.4.1.10520.2.1.3.20.1.1 integer read-only
Table Index
                                   ne843CoeEntryIde 1.3.6.1.4.1.10520.2.1.3.20.1.2 displaystring read-only
Identifier
                                   ne843CoeEntryDes 1.3.6.1.4.1.10520.2.1.3.20.1.3 displaystring read-write
Description
                                   ne843CoeEntryAdr 1.3.6.1.4.1.10520.2.1.3.20.1.4 displaystring read-write
Email Address
                                   ne843CoeEntryTyp 1.3.6.1.4.1.10520.2.1.3.20.1.5 displaystring read-write
Address Type Values: NORMAL, PAGER
                         ne843SndTable 1.3.6.1.4.1.10520.2.1.3.21 no-access
Table of all SNMP Trap Destination data
                               ne843SndEntry 1.3.6.1.4.1.10520.2.1.3.21.1 no-access
Entry of information for one SNMP Trap Destination
                                   ne843SndEntryIndex 1.3.6.1.4.1.10520.2.1.3.21.1.1 integer read-only
Table Index
                                   ne843SndEntryIde 1.3.6.1.4.1.10520.2.1.3.21.1.2 displaystring read-only
Identifier
                                   ne843SndEntryDes 1.3.6.1.4.1.10520.2.1.3.21.1.3 displaystring read-write
Description
                                   ne843SndEntryIp 1.3.6.1.4.1.10520.2.1.3.21.1.4 displaystring read-write
IP Address
                                   ne843SndEntryCs 1.3.6.1.4.1.10520.2.1.3.21.1.5 displaystring read-write
Community String
                         ne843Po1 1.3.6.1.4.1.10520.2.1.3.22
                               ne843Po1Ide 1.3.6.1.4.1.10520.2.1.3.22.1 displaystring read-only
Identifier
                               ne843Po1Des 1.3.6.1.4.1.10520.2.1.3.22.2 displaystring read-write
Description
                               ne843Po1Phn 1.3.6.1.4.1.10520.2.1.3.22.3 displaystring read-write
Phone Number
                               ne843Po1Bdr 1.3.6.1.4.1.10520.2.1.3.22.4 integer read-write
Connect Baudrate Values: b300(300), b1200(1200), b2400(2400), b4800(4800), b9600(9600), b19200(19200) Enumeration: 'b9600': 9600, 'b1200': 1200, 'b2400': 2400, 'b19200': 19200, 'b300': 300, 'b4800': 4800.
                               ne843Po1Dbt 1.3.6.1.4.1.10520.2.1.3.22.5 integer read-write
Data Bits Values: d7(7), d8(8) Enumeration: 'd7': 7, 'd8': 8.
                               ne843Po1Pry 1.3.6.1.4.1.10520.2.1.3.22.6 displaystring read-write
Parity Values: O, E, N
                               ne843Po1Sbt 1.3.6.1.4.1.10520.2.1.3.22.7 integer read-write
Stop Bits Values: s1(1), s2(2) Enumeration: 's2': 2, 's1': 1.
                               ne843Po1Int 1.3.6.1.4.1.10520.2.1.3.22.8 displaystring read-write
Interval Values: Sunday, Monday, Tuesday, Wednesday, Thursday, Friday, Saturday, Daily, Monthly, Quarterly, Never
                               ne843Po1Tim 1.3.6.1.4.1.10520.2.1.3.22.9 displaystring read-write
Time
                               ne843Po1Cl01 1.3.6.1.4.1.10520.2.1.3.22.10 displaystring read-write
Command Line 1
                               ne843Po1Cl02 1.3.6.1.4.1.10520.2.1.3.22.11 displaystring read-write
Command Line 2
                               ne843Po1Cl03 1.3.6.1.4.1.10520.2.1.3.22.12 displaystring read-write
Command Line 3
                               ne843Po1Cl04 1.3.6.1.4.1.10520.2.1.3.22.13 displaystring read-write
Command Line 4
                               ne843Po1Cl05 1.3.6.1.4.1.10520.2.1.3.22.14 displaystring read-write
Command Line 5
                               ne843Po1Cl06 1.3.6.1.4.1.10520.2.1.3.22.15 displaystring read-write
Command Line 6
                               ne843Po1Cl07 1.3.6.1.4.1.10520.2.1.3.22.16 displaystring read-write
Command Line 7
                               ne843Po1Cl08 1.3.6.1.4.1.10520.2.1.3.22.17 displaystring read-write
Command Line 8
                               ne843Po1Cl09 1.3.6.1.4.1.10520.2.1.3.22.18 displaystring read-write
Command Line 9
                               ne843Po1Cl10 1.3.6.1.4.1.10520.2.1.3.22.19 displaystring read-write
Command Line 10
                               ne843Po1Por 1.3.6.1.4.1.10520.2.1.3.22.20 displaystring read-only
Number Did Not Respond Value: Alarm report from POR1
                         ne843Cb1 1.3.6.1.4.1.10520.2.1.3.23
                               ne843Cb1Ide 1.3.6.1.4.1.10520.2.1.3.23.1 displaystring read-only
Identifier
                               ne843Cb1Des 1.3.6.1.4.1.10520.2.1.3.23.2 displaystring read-write
Description
                               ne843Cb1Stt 1.3.6.1.4.1.10520.2.1.3.23.3 integer read-write
State Values: off(0), on(1) Enumeration: 'on': 1, 'off': 0.
                               ne843Cb1Ph1 1.3.6.1.4.1.10520.2.1.3.23.4 displaystring read-write
Call-Back Phone Number 1
                               ne843Cb1Br1 1.3.6.1.4.1.10520.2.1.3.23.5 integer read-write
Connect Baudrate 1 Values: b300(300), b1200(1200), b2400(2400), b4800(4800), b9600(9600), b19200(19200) Enumeration: 'b9600': 9600, 'b1200': 1200, 'b2400': 2400, 'b19200': 19200, 'b300': 300, 'b4800': 4800.
                               ne843Cb1Ph2 1.3.6.1.4.1.10520.2.1.3.23.6 displaystring read-write
Call-Back Phone Number 2
                               ne843Cb1Br2 1.3.6.1.4.1.10520.2.1.3.23.7 integer read-write
Connect Baudrate 2 Values: b300(300), b1200(1200), b2400(2400), b4800(4800), b9600(9600), b19200(19200) Enumeration: 'b9600': 9600, 'b1200': 1200, 'b2400': 2400, 'b19200': 19200, 'b300': 300, 'b4800': 4800.
                               ne843Cb1Ph3 1.3.6.1.4.1.10520.2.1.3.23.8 displaystring read-write
Call-Back Phone Number 3
                               ne843Cb1Br3 1.3.6.1.4.1.10520.2.1.3.23.9 integer read-write
Connect Baudrate 3 Values: b300(300), b1200(1200), b2400(2400), b4800(4800), b9600(9600), b19200(19200) Enumeration: 'b9600': 9600, 'b1200': 1200, 'b2400': 2400, 'b19200': 19200, 'b300': 300, 'b4800': 4800.
                               ne843Cb1Ph4 1.3.6.1.4.1.10520.2.1.3.23.10 displaystring read-write
Call-Back Phone Number 4
                               ne843Cb1Br4 1.3.6.1.4.1.10520.2.1.3.23.11 integer read-write
Connect Baudrate 4 Values: b300(300), b1200(1200), b2400(2400), b4800(4800), b9600(9600), b19200(19200) Enumeration: 'b9600': 9600, 'b1200': 1200, 'b2400': 2400, 'b19200': 19200, 'b300': 300, 'b4800': 4800.
                               ne843Cb1Ph5 1.3.6.1.4.1.10520.2.1.3.23.12 displaystring read-write
Call-Back Phone Number 5
                               ne843Cb1Br5 1.3.6.1.4.1.10520.2.1.3.23.13 integer read-write
Connect Baudrate 5 Values: b300(300), b1200(1200), b2400(2400), b4800(4800), b9600(9600), b19200(19200) Enumeration: 'b9600': 9600, 'b1200': 1200, 'b2400': 2400, 'b19200': 19200, 'b300': 300, 'b4800': 4800.
                         ne843Mp1 1.3.6.1.4.1.10520.2.1.3.24
                               ne843Mp1Ide 1.3.6.1.4.1.10520.2.1.3.24.1 displaystring read-only
Identifier
                               ne843Mp1Des 1.3.6.1.4.1.10520.2.1.3.24.2 displaystring read-write
Description
                               ne843Mp1Stt 1.3.6.1.4.1.10520.2.1.3.24.3 displaystring read-only
State
                               ne843Mp1Bdr 1.3.6.1.4.1.10520.2.1.3.24.4 integer read-write
Baudrate Values: b300(300), b1200(1200), b2400(2400), b4800(4800), b9600(9600), b19200(19200) Enumeration: 'b9600': 9600, 'b1200': 1200, 'b2400': 2400, 'b19200': 19200, 'b300': 300, 'b4800': 4800.
                               ne843Mp1Dbt 1.3.6.1.4.1.10520.2.1.3.24.5 integer read-write
Data Bits Values: d7(7), d8(8) Enumeration: 'd7': 7, 'd8': 8.
                               ne843Mp1Pry 1.3.6.1.4.1.10520.2.1.3.24.6 displaystring read-write
Parity Values: O, E, N
                               ne843Mp1Sbt 1.3.6.1.4.1.10520.2.1.3.24.7 integer read-write
Stop Bits Values: s1(1), s2(2) Enumeration: 's2': 2, 's1': 1.
                               ne843Mp1Tmo 1.3.6.1.4.1.10520.2.1.3.24.8 integer32 read-write
Time-Out
                               ne843Mp1Hsh 1.3.6.1.4.1.10520.2.1.3.24.9 displaystring read-write
Handshaking Values: NO, SW
                               ne843Mp1Nrg 1.3.6.1.4.1.10520.2.1.3.24.10 integer32 read-write
Number of Rings Before Answer
                               ne843Mp1Wre 1.3.6.1.4.1.10520.2.1.3.24.11 integer read-write
Write Enable Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                               ne843Mp1Ins 1.3.6.1.4.1.10520.2.1.3.24.12 displaystring read-write
Modem Init String
                         ne843Lp1 1.3.6.1.4.1.10520.2.1.3.25
                               ne843Lp1Ide 1.3.6.1.4.1.10520.2.1.3.25.1 displaystring read-only
Identifier
                               ne843Lp1Des 1.3.6.1.4.1.10520.2.1.3.25.2 displaystring read-write
Description
                               ne843Lp1Stt 1.3.6.1.4.1.10520.2.1.3.25.3 displaystring read-only
State
                               ne843Lp1Bdr 1.3.6.1.4.1.10520.2.1.3.25.4 integer read-write
Baudrate Values: b300(300), b1200(1200), b2400(2400), b4800(4800), b9600(9600), b19200(19200) Enumeration: 'b9600': 9600, 'b1200': 1200, 'b2400': 2400, 'b19200': 19200, 'b300': 300, 'b4800': 4800.
                               ne843Lp1Dbt 1.3.6.1.4.1.10520.2.1.3.25.5 integer read-write
Data Bits Values: d7(7), d8(8) Enumeration: 'd7': 7, 'd8': 8.
                               ne843Lp1Pry 1.3.6.1.4.1.10520.2.1.3.25.6 displaystring read-write
Parity Values: O, E, N
                               ne843Lp1Sbt 1.3.6.1.4.1.10520.2.1.3.25.7 integer read-write
Stop Bits Values: s1(1), s2(2) Enumeration: 's2': 2, 's1': 1.
                               ne843Lp1Tmo 1.3.6.1.4.1.10520.2.1.3.25.8 integer32 read-write
Time-Out
                               ne843Lp1Hsh 1.3.6.1.4.1.10520.2.1.3.25.9 displaystring read-write
Handshaking Values: NO, HW, SW
                               ne843Lp1App 1.3.6.1.4.1.10520.2.1.3.25.10 displaystring read-write
Application Values: TERMINAL, EVENT LOG
                               ne843Lp1Wre 1.3.6.1.4.1.10520.2.1.3.25.11 integer read-write
Write Enable Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                         ne843Tlm1 1.3.6.1.4.1.10520.2.1.3.26
                               ne843Tlm1Ide 1.3.6.1.4.1.10520.2.1.3.26.1 displaystring read-only
Identifier
                               ne843Tlm1Des 1.3.6.1.4.1.10520.2.1.3.26.2 displaystring read-write
Description
                               ne843Tlm1Aue 1.3.6.1.4.1.10520.2.1.3.26.3 integer read-write
Activate-User Enable Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                               ne843Tlm1Prt 1.3.6.1.4.1.10520.2.1.3.26.4 integer32 read-write
TCP/IP Port
                               ne843Tlm1Tmo 1.3.6.1.4.1.10520.2.1.3.26.5 integer32 read-write
Timeout (Minutes)
                         ne843Tl1Table 1.3.6.1.4.1.10520.2.1.3.27 no-access
Table of all TL1 Object data
                               ne843Tl1Entry 1.3.6.1.4.1.10520.2.1.3.27.1 no-access
Entry of information for one TL1 Object
                                   ne843Tl1EntryIndex 1.3.6.1.4.1.10520.2.1.3.27.1.1 integer read-only
Table Index
                                   ne843Tl1EntryIde 1.3.6.1.4.1.10520.2.1.3.27.1.2 displaystring read-only
Identifier
                                   ne843Tl1EntryDes 1.3.6.1.4.1.10520.2.1.3.27.1.3 displaystring read-write
Description
                                   ne843Tl1EntryCds 1.3.6.1.4.1.10520.2.1.3.27.1.4 displaystring read-write
Condition Description
                                   ne843Tl1EntryAid 1.3.6.1.4.1.10520.2.1.3.27.1.5 displaystring read-write
Aid
                                   ne843Tl1EntryCnd 1.3.6.1.4.1.10520.2.1.3.27.1.6 displaystring read-write
Condition Type
                                   ne843Tl1EntrySaf 1.3.6.1.4.1.10520.2.1.3.27.1.7 integer read-write
Service Affecting Values: no(0), yes(1) Enumeration: 'yes': 1, 'no': 0.
                                   ne843Tl1EntryRpt 1.3.6.1.4.1.10520.2.1.3.27.1.8 displaystring read-write
Reporting Values: EQUIPMENT, ENVIRONMENT, PRESENCE
                         ne843Net1 1.3.6.1.4.1.10520.2.1.3.28
                               ne843Net1Ide 1.3.6.1.4.1.10520.2.1.3.28.1 displaystring read-only
Identifier
                               ne843Net1Des 1.3.6.1.4.1.10520.2.1.3.28.2 displaystring read-write
Description
                               ne843Net1Ead 1.3.6.1.4.1.10520.2.1.3.28.3 displaystring read-only
Ethernet Address
                               ne843Net1Dhcp 1.3.6.1.4.1.10520.2.1.3.28.4 integer read-write
IP Addressing Mode Values: static(0), dhcpClient(1), dhcpServer(2) Enumeration: 'dhcpClient': 1, 'static': 0, 'dhcpServer': 2.
                               ne843Net1Ip 1.3.6.1.4.1.10520.2.1.3.28.5 displaystring read-write
Static IPv4 Address
                               ne843Net1Wip 1.3.6.1.4.1.10520.2.1.3.28.6 displaystring read-only
Working IPv4 Address
                               ne843Net1Sub 1.3.6.1.4.1.10520.2.1.3.28.7 displaystring read-write
Subnet Mask
                               ne843Net1Gtwy 1.3.6.1.4.1.10520.2.1.3.28.8 displaystring read-write
Default Gateway
                               ne843Net1Host 1.3.6.1.4.1.10520.2.1.3.28.9 displaystring read-write
Host Name
                               ne843Net1Dom 1.3.6.1.4.1.10520.2.1.3.28.10 displaystring read-write
Domain Name
                               ne843Net1Dns 1.3.6.1.4.1.10520.2.1.3.28.11 displaystring read-write
DNS Server Address
                               ne843Net1Wre 1.3.6.1.4.1.10520.2.1.3.28.12 integer read-write
Write Enable Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                               ne843Net1Tmo 1.3.6.1.4.1.10520.2.1.3.28.13 integer32 read-write
Timeout (Minutes)
                               ne843Net1Msrv 1.3.6.1.4.1.10520.2.1.3.28.14 displaystring read-write
Mail Server Address
                               ne843Net1Ntp 1.3.6.1.4.1.10520.2.1.3.28.15 displaystring read-write
Time Server Address
                               ne843Net1Sma 1.3.6.1.4.1.10520.2.1.3.28.16 displaystring read-write
Send Email As
                               ne843Net1Sid 1.3.6.1.4.1.10520.2.1.3.28.17 displaystring read-only
SNMP Engine ID
                               ne843Net1Fpe 1.3.6.1.4.1.10520.2.1.3.28.18 integer read-write
FTP Access Enable Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                               ne843Net1Hpe 1.3.6.1.4.1.10520.2.1.3.28.19 integer read-write
HTTP Web Access Enable Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                               ne843Net1Hse 1.3.6.1.4.1.10520.2.1.3.28.20 integer read-write
HTTPS Web Access Enable Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                               ne843Net1She 1.3.6.1.4.1.10520.2.1.3.28.21 integer read-write
SSH Access Enable Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                               ne843Net1Sne 1.3.6.1.4.1.10520.2.1.3.28.22 integer read-write
SNMP Access Enable Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                               ne843Net1Tle 1.3.6.1.4.1.10520.2.1.3.28.23 integer read-write
Telnet Access Enable Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                               ne843Net1Ip6 1.3.6.1.4.1.10520.2.1.3.28.24 displaystring read-write
Static IPv6 Address
                               ne843Net1Gtwy6 1.3.6.1.4.1.10520.2.1.3.28.25 displaystring read-write
Static IPv6 Gateway/Router
                               ne843Net1Wip6 1.3.6.1.4.1.10520.2.1.3.28.26 displaystring read-only
Working IPv6 Address
                               ne843Net1Ll6 1.3.6.1.4.1.10520.2.1.3.28.27 displaystring read-only
Working IPv6 Link Local Address
                               ne843Net1Pl6 1.3.6.1.4.1.10520.2.1.3.28.28 integer32 read-write
IPv6 Prefix Length
                               ne843Net1Wgtwy6 1.3.6.1.4.1.10520.2.1.3.28.29 displaystring read-only
Working IPv6 Gateway/Router Address
                         ne843DrcTable 1.3.6.1.4.1.10520.2.1.3.29 no-access
Table of all Derived Channel data
                               ne843DrcEntry 1.3.6.1.4.1.10520.2.1.3.29.1 no-access
Entry of information for one Derived Channel
                                   ne843DrcEntryIndex 1.3.6.1.4.1.10520.2.1.3.29.1.1 integer read-only
Table Index
                                   ne843DrcEntryIde 1.3.6.1.4.1.10520.2.1.3.29.1.2 displaystring read-only
Identifier
                                   ne843DrcEntryDes 1.3.6.1.4.1.10520.2.1.3.29.1.3 displaystring read-write
Description
                                   ne843DrcEntryVal 1.3.6.1.4.1.10520.2.1.3.29.1.4 displaystring read-only
Value
                                   ne843DrcEntryPrg 1.3.6.1.4.1.10520.2.1.3.29.1.5 displaystring read-write
Program Line
                                   ne843DrcEntryUni 1.3.6.1.4.1.10520.2.1.3.29.1.6 displaystring read-write
Unit
                         ne843InpTable 1.3.6.1.4.1.10520.2.1.3.30 no-access
Table of all Input Management data
                               ne843InpEntry 1.3.6.1.4.1.10520.2.1.3.30.1 no-access
Entry of information for one Input Management
                                   ne843InpEntryIndex 1.3.6.1.4.1.10520.2.1.3.30.1.1 integer read-only
Table Index
                                   ne843InpEntryIde 1.3.6.1.4.1.10520.2.1.3.30.1.2 displaystring read-only
Identifier
                                   ne843InpEntryDes 1.3.6.1.4.1.10520.2.1.3.30.1.3 displaystring read-write
Description
                                   ne843InpEntryStt 1.3.6.1.4.1.10520.2.1.3.30.1.4 integer read-only
Input State Values: alarming(1), nonAlarming(0) Enumeration: 'alarming': 1, 'nonAlarming': 0.
                                   ne843InpEntryTyp 1.3.6.1.4.1.10520.2.1.3.30.1.5 displaystring read-write
Type Alarm Object ID or, REMLVD for Remote LVD
                                   ne843InpEntryPol 1.3.6.1.4.1.10520.2.1.3.30.1.6 displaystring read-write
Input Alarming Polarity Values: OPEN, CLOSED
                                   ne843InpEntrySn 1.3.6.1.4.1.10520.2.1.3.30.1.7 displaystring read-only
Serial Number
                                   ne843InpEntryBrc 1.3.6.1.4.1.10520.2.1.3.30.1.8 displaystring read-only
Board Code
                         ne843MsvTable 1.3.6.1.4.1.10520.2.1.3.31 no-access
Table of all Midstring Voltage Monitor data
                               ne843MsvEntry 1.3.6.1.4.1.10520.2.1.3.31.1 no-access
Entry of information for one Midstring Voltage Monitor
                                   ne843MsvEntryIndex 1.3.6.1.4.1.10520.2.1.3.31.1.1 integer read-only
Table Index
                                   ne843MsvEntryIde 1.3.6.1.4.1.10520.2.1.3.31.1.2 displaystring read-only
Identifier
                                   ne843MsvEntryDes 1.3.6.1.4.1.10520.2.1.3.31.1.3 displaystring read-write
Description
                                   ne843MsvEntryStt 1.3.6.1.4.1.10520.2.1.3.31.1.4 displaystring read-only
State
                                   ne843MsvEntryVal 1.3.6.1.4.1.10520.2.1.3.31.1.5 integer32 read-only
Value (mV)
                                   ne843MsvEntryDid 1.3.6.1.4.1.10520.2.1.3.31.1.6 displaystring read-only
Duplicate ID
                                   ne843MsvEntryDid1 1.3.6.1.4.1.10520.2.1.3.31.1.7 integer read-only
Duplicate ID Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                         ne843Rp1 1.3.6.1.4.1.10520.2.1.3.32
                               ne843Rp1Ide 1.3.6.1.4.1.10520.2.1.3.32.1 displaystring read-only
Identifier
                               ne843Rp1Des 1.3.6.1.4.1.10520.2.1.3.32.2 displaystring read-write
Description
                               ne843Rp1Frq 1.3.6.1.4.1.10520.2.1.3.32.3 integer32 read-write
Frequency (Hz)
                               ne843Rp1Vsp 1.3.6.1.4.1.10520.2.1.3.32.4 integer32 read-write
Voltage Set-point (Volts)
                               ne843Rp1Ofe 1.3.6.1.4.1.10520.2.1.3.32.5 integer read-write
Offset Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                               ne843Rp1Rme 1.3.6.1.4.1.10520.2.1.3.32.6 integer read-write
Redundancy Monitor Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                               ne843Rp1Rss 1.3.6.1.4.1.10520.2.1.3.32.7 integer read-write
Restart Values: restart(1) Enumeration: 'restart': 1.
                               ne843Rp1Rf 1.3.6.1.4.1.10520.2.1.3.32.8 displaystring read-only
Ringer Minor Fail Value: Alarm report from RFN1
                               ne843Rp1Rpff 1.3.6.1.4.1.10520.2.1.3.32.9 displaystring read-only
Ringer Fan Fail Value: Alarm report from RPFF1
                               ne843Rp1Rprl 1.3.6.1.4.1.10520.2.1.3.32.10 displaystring read-only
Ringer Redundancy Loss Value: Alarm report from RPRL1
                               ne843Rp1Rpfj 1.3.6.1.4.1.10520.2.1.3.32.11 displaystring read-only
Ringer Major Fail Value: Alarm report from RPFJ1
                               ne843Rp1Rpxj 1.3.6.1.4.1.10520.2.1.3.32.12 displaystring read-only
Ringer Major External Fault Value: Alarm report from RPXJ1
                               ne843Rp1Rpxn 1.3.6.1.4.1.10520.2.1.3.32.13 displaystring read-only
Ringer Minor External Fault Value: Alarm report from RPXN1
                               ne843Rp1Rcdp 1.3.6.1.4.1.10520.2.1.3.32.14 displaystring read-only
Ringer ID Conflict Value: Alarm report from RCDP1
                               ne843Rp1Cap 1.3.6.1.4.1.10520.2.1.3.32.15 integer32 read-only
Capacity (VA)
                               ne843Rp1Olcap 1.3.6.1.4.1.10520.2.1.3.32.16 integer32 read-only
On Line Capacity (VA)
                               ne843Rp1Va 1.3.6.1.4.1.10520.2.1.3.32.17 integer32 read-only
Total (VA)
                               ne843Rp1Rrf 1.3.6.1.4.1.10520.2.1.3.32.18 integer read-write
Standby Enable Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                         ne843RchTable 1.3.6.1.4.1.10520.2.1.3.33 no-access
Table of all Ringer Chassis data
                               ne843RchEntry 1.3.6.1.4.1.10520.2.1.3.33.1 no-access
Entry of information for one Ringer Chassis
                                   ne843RchEntryIndex 1.3.6.1.4.1.10520.2.1.3.33.1.1 integer read-only
Table Index
                                   ne843RchEntryIde 1.3.6.1.4.1.10520.2.1.3.33.1.2 displaystring read-only
Identifier
                                   ne843RchEntryDes 1.3.6.1.4.1.10520.2.1.3.33.1.3 displaystring read-write
Description
                                   ne843RchEntryStt 1.3.6.1.4.1.10520.2.1.3.33.1.4 displaystring read-write
Ringer Group State
                                   ne843RchEntryVa 1.3.6.1.4.1.10520.2.1.3.33.1.5 integer32 read-only
Ringer Output (mVA)
                                   ne843RchEntryPri 1.3.6.1.4.1.10520.2.1.3.33.1.6 displaystring read-only
Primary Ringer
                                   ne843RchEntrySec 1.3.6.1.4.1.10520.2.1.3.33.1.7 displaystring read-only
Secondary Ringer
                                   ne843RchEntryRf 1.3.6.1.4.1.10520.2.1.3.33.1.8 integer read-only
Ringer Minor Fail Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                                   ne843RchEntryRpff 1.3.6.1.4.1.10520.2.1.3.33.1.9 integer read-only
Ringer Fan Fail Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                                   ne843RchEntryRpxj 1.3.6.1.4.1.10520.2.1.3.33.1.10 integer read-only
Ringer Major External Fault Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                                   ne843RchEntryRpxn 1.3.6.1.4.1.10520.2.1.3.33.1.11 integer read-only
Ringer Minor External Fault Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                                   ne843RchEntryRprl 1.3.6.1.4.1.10520.2.1.3.33.1.12 integer read-only
Ringer Redundancy Loss Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                                   ne843RchEntryRpfj 1.3.6.1.4.1.10520.2.1.3.33.1.13 integer read-only
Ringer Major Fail Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                                   ne843RchEntryRcdp 1.3.6.1.4.1.10520.2.1.3.33.1.14 integer read-only
Ringer ID Conflict Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                                   ne843RchEntryPsn 1.3.6.1.4.1.10520.2.1.3.33.1.15 displaystring read-only
Primary Serial Number
                                   ne843RchEntryPtyp 1.3.6.1.4.1.10520.2.1.3.33.1.16 displaystring read-only
Primary Type
                                   ne843RchEntryPstt 1.3.6.1.4.1.10520.2.1.3.33.1.17 displaystring read-only
Primary Ringer State
                                   ne843RchEntrySsn 1.3.6.1.4.1.10520.2.1.3.33.1.18 displaystring read-only
Secondary Serial Number
                                   ne843RchEntryStyp 1.3.6.1.4.1.10520.2.1.3.33.1.19 displaystring read-only
Secondary Type
                                   ne843RchEntrySstt 1.3.6.1.4.1.10520.2.1.3.33.1.20 displaystring read-only
Secondary Ringer State
                                   ne843RchEntryCap 1.3.6.1.4.1.10520.2.1.3.33.1.21 integer32 read-only
Capacity (VA)
                         ne843AlarmTable 1.3.6.1.4.1.10520.2.1.3.34 no-access
Table of all Alarm data
                               ne843AlarmEntry 1.3.6.1.4.1.10520.2.1.3.34.1 no-access
Entry of information for one Alarm
                                   ne843AlarmEntryIndex 1.3.6.1.4.1.10520.2.1.3.34.1.1 integer read-only
Table Index
                                   ne843AlarmEntryDes 1.3.6.1.4.1.10520.2.1.3.34.1.2 displaystring read-write
Description
                                   ne843AlarmEntryAst 1.3.6.1.4.1.10520.2.1.3.34.1.3 integer read-only
State Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                                   ne843AlarmEntrySev 1.3.6.1.4.1.10520.2.1.3.34.1.4 displaystring read-write
Severity
                                   ne843AlarmEntryAcc 1.3.6.1.4.1.10520.2.1.3.34.1.5 displaystring read-write
Contact Closure Values: , R1, R2, R3, R4, R5, R6, R7
                                   ne843AlarmEntryThr 1.3.6.1.4.1.10520.2.1.3.34.1.6 displaystring read-write
Threshold
                                   ne843AlarmEntryFth 1.3.6.1.4.1.10520.2.1.3.34.1.7 integer32 read-write
Float Threshold (mV)
                                   ne843AlarmEntryBth 1.3.6.1.4.1.10520.2.1.3.34.1.8 integer32 read-write
Boost Threshold (mV)
                                   ne843AlarmEntryDly 1.3.6.1.4.1.10520.2.1.3.34.1.9 integer32 read-write
Notify Delay (Seconds)
                                   ne843AlarmEntryNoo 1.3.6.1.4.1.10520.2.1.3.34.1.10 integer read-write
Notify On Occur Values: no(0), yes(1) Enumeration: 'yes': 1, 'no': 0.
                                   ne843AlarmEntryNor 1.3.6.1.4.1.10520.2.1.3.34.1.11 integer read-write
Notify On Retire Values: no(0), yes(1) Enumeration: 'yes': 1, 'no': 0.
                                   ne843AlarmEntryNag 1.3.6.1.4.1.10520.2.1.3.34.1.12 integer read-write
Nag on Occur Values: no(0), yes(1) Enumeration: 'yes': 1, 'no': 0.
                                   ne843AlarmEntryDst 1.3.6.1.4.1.10520.2.1.3.34.1.13 displaystring read-write
Notify Destination
                         ne843Trap 1.3.6.1.4.1.10520.2.1.3.35
                               ne843TrapDc1Amj 1.3.6.1.4.1.10520.2.1.3.35.1
Auxiliary Fuse Major
                               ne843TrapDc1Vsf 1.3.6.1.4.1.10520.2.1.3.35.2
Sense/Control Fuse
                               ne843TrapDc1Osa 1.3.6.1.4.1.10520.2.1.3.35.3
Open String
                               ne843TrapDc1Zid 1.3.6.1.4.1.10520.2.1.3.35.4
ID Not Configured
                               ne843TrapDc1Tpa 1.3.6.1.4.1.10520.2.1.3.35.5
Thermal Probe Alarm
                               ne843TrapDc1Vmf 1.3.6.1.4.1.10520.2.1.3.35.6
Voltage Module Fail
                               ne843TrapDc1Cma 1.3.6.1.4.1.10520.2.1.3.35.7
Minor Communication Failure
                               ne843TrapDc1Mcm 1.3.6.1.4.1.10520.2.1.3.35.8
Major Communication Failure
                               ne843TrapDc1Epo 1.3.6.1.4.1.10520.2.1.3.35.9
Emergency Power Off
                               ne843TrapDc1Icr 1.3.6.1.4.1.10520.2.1.3.35.10
Incompatible Rectifier
                               ne843TrapDc1Rfa 1.3.6.1.4.1.10520.2.1.3.35.11
Rectifier Fail
                               ne843TrapDc1Acf 1.3.6.1.4.1.10520.2.1.3.35.12
AC Fail
                               ne843TrapDc1Man 1.3.6.1.4.1.10520.2.1.3.35.13
Manual Off
                               ne843TrapDc1Did 1.3.6.1.4.1.10520.2.1.3.35.14
ID Conflict
                               ne843TrapDc1Clm 1.3.6.1.4.1.10520.2.1.3.35.15
Rectifier Current Limit
                               ne843TrapDc1Rfn 1.3.6.1.4.1.10520.2.1.3.35.16
Rectifier Fan Failure
                               ne843TrapDc1Vla 1.3.6.1.4.1.10520.2.1.3.35.17
Very Low Voltage
                               ne843TrapDc1Mfa 1.3.6.1.4.1.10520.2.1.3.35.18
Multiple Rectifier Fail
                               ne843TrapDc1Rtl 1.3.6.1.4.1.10520.2.1.3.35.19
Reserve Time Low
                               ne843TrapDc1Rrtl 1.3.6.1.4.1.10520.2.1.3.35.20
Real-time Reserve Time Low
                               ne843TrapDc1Rls 1.3.6.1.4.1.10520.2.1.3.35.21
Redundancy Loss
                               ne843TrapDc1Mman 1.3.6.1.4.1.10520.2.1.3.35.22
Multiple Manual Off
                               ne843TrapDc1Macf 1.3.6.1.4.1.10520.2.1.3.35.23
Multiple AC Failure
                               ne843TrapDc1Bda 1.3.6.1.4.1.10520.2.1.3.35.24
Battery On Discharge
                               ne843TrapDc1Hva 1.3.6.1.4.1.10520.2.1.3.35.25
High Voltage
                               ne843TrapDc1Hfv 1.3.6.1.4.1.10520.2.1.3.35.26
High Float Voltage
                               ne843TrapPs1Epr 1.3.6.1.4.1.10520.2.1.3.35.27
External Password Reset
                               ne843TrapPs1Pfd 1.3.6.1.4.1.10520.2.1.3.35.28
Passwords At Default
                               ne843TrapPs1Exl 1.3.6.1.4.1.10520.2.1.3.35.29
Excessive Login Attempts
                               ne843TrapPs1Bbl 1.3.6.1.4.1.10520.2.1.3.35.30
Memory Backup Battery Low
                               ne843TrapPs1Clc 1.3.6.1.4.1.10520.2.1.3.35.31
Clock Changed
                               ne843TrapPs1Stf 1.3.6.1.4.1.10520.2.1.3.35.32
Self Test Failed
                               ne843TrapPs1Pgi 1.3.6.1.4.1.10520.2.1.3.35.33
Program Line Invalid
                               ne843TrapPs1Cch 1.3.6.1.4.1.10520.2.1.3.35.34
Configuration Changed
                               ne843TrapPs1Hcl 1.3.6.1.4.1.10520.2.1.3.35.35
History Cleared
                               ne843TrapPs1Ax1 1.3.6.1.4.1.10520.2.1.3.35.36
Auxiliary Event 1
                               ne843TrapPs1Ax2 1.3.6.1.4.1.10520.2.1.3.35.37
Auxiliary Event 2
                               ne843TrapPs1Ax3 1.3.6.1.4.1.10520.2.1.3.35.38
Auxiliary Event 3
                               ne843TrapPs1Ax4 1.3.6.1.4.1.10520.2.1.3.35.39
Auxiliary Event 4
                               ne843TrapPs1Ax5 1.3.6.1.4.1.10520.2.1.3.35.40
Auxiliary Event 5
                               ne843TrapPs1Ax6 1.3.6.1.4.1.10520.2.1.3.35.41
Auxiliary Event 6
                               ne843TrapPs1Fan24 1.3.6.1.4.1.10520.2.1.3.35.42
24 V Fuse Minor
                               ne843TrapPs1Fan48 1.3.6.1.4.1.10520.2.1.3.35.43
48 V Fuse Minor
                               ne843TrapPs1Faj24 1.3.6.1.4.1.10520.2.1.3.35.44
24 V Fuse Major
                               ne843TrapPs1Faj48 1.3.6.1.4.1.10520.2.1.3.35.45
48 V Fuse Major
                               ne843TrapAt1Ata 1.3.6.1.4.1.10520.2.1.3.35.46
Alarm Test Active
                               ne843TrapAt1Atb 1.3.6.1.4.1.10520.2.1.3.35.47
Alarm Test Aborted
                               ne843TrapCp1Cfa 1.3.6.1.4.1.10520.2.1.3.35.48
Converter Fail
                               ne843TrapCp1Cfn 1.3.6.1.4.1.10520.2.1.3.35.49
Converter Fan Minor
                               ne843TrapCp1Cfj 1.3.6.1.4.1.10520.2.1.3.35.50
Converter Fan Major
                               ne843TrapCp1Dfa 1.3.6.1.4.1.10520.2.1.3.35.51
Distribution Fail
                               ne843TrapCp1Did 1.3.6.1.4.1.10520.2.1.3.35.52
ID Conflict
                               ne843TrapCp1Icc 1.3.6.1.4.1.10520.2.1.3.35.53
Incompatible Converter Alarm
                               ne843TrapCp1Mfa 1.3.6.1.4.1.10520.2.1.3.35.54
Multiple Converter Fail
                               ne843TrapCp1Hva 1.3.6.1.4.1.10520.2.1.3.35.55
Converter High Voltage Major
                               ne843TrapCp1Hfv 1.3.6.1.4.1.10520.2.1.3.35.56
Converter High Voltage Minor
                               ne843TrapCp1Vla 1.3.6.1.4.1.10520.2.1.3.35.57
Converter Very Low Voltage
                               ne843TrapCp1Rl 1.3.6.1.4.1.10520.2.1.3.35.58
Converter Redundancy Loss
                               ne843TrapBr1Bta 1.3.6.1.4.1.10520.2.1.3.35.59
Battery Test Active
                               ne843TrapBr1Bfa 1.3.6.1.4.1.10520.2.1.3.35.60
Battery Test Failed
                               ne843TrapBr1Scda 1.3.6.1.4.1.10520.2.1.3.35.61
Shorted Cell Detected
                               ne843TrapBr1Isda 1.3.6.1.4.1.10520.2.1.3.35.62
Imminent Shutdown
                               ne843TrapBr1Mdp 1.3.6.1.4.1.10520.2.1.3.35.63
Voltage Duplicate ID
                               ne843TrapBr1Mzd 1.3.6.1.4.1.10520.2.1.3.35.64
Voltage ID Not Configured
                               ne843TrapBr1Btha 1.3.6.1.4.1.10520.2.1.3.35.65
High Battery Temperature
                               ne843TrapCn1Cno 1.3.6.1.4.1.10520.2.1.3.35.66
Contactor Open
                               ne843TrapCn1Cnf 1.3.6.1.4.1.10520.2.1.3.35.67
Contactor Failed
                               ne843TrapCn2Cno 1.3.6.1.4.1.10520.2.1.3.35.68
Contactor Open
                               ne843TrapCn2Cnf 1.3.6.1.4.1.10520.2.1.3.35.69
Contactor Failed
                               ne843TrapCn3Cno 1.3.6.1.4.1.10520.2.1.3.35.70
Contactor Open
                               ne843TrapCn3Cnf 1.3.6.1.4.1.10520.2.1.3.35.71
Contactor Failed
                               ne843TrapCn4Cno 1.3.6.1.4.1.10520.2.1.3.35.72
Contactor Open
                               ne843TrapCn4Cnf 1.3.6.1.4.1.10520.2.1.3.35.73
Contactor Failed
                               ne843TrapCm1Cof 1.3.6.1.4.1.10520.2.1.3.35.74
Queue Overflow
                               ne843TrapCm1Cor 1.3.6.1.4.1.10520.2.1.3.35.75
Number Did Not Respond
                               ne843TrapCm1Nnc 1.3.6.1.4.1.10520.2.1.3.35.76
Number Not Configured
                               ne843TrapPo1Por 1.3.6.1.4.1.10520.2.1.3.35.77
Number Did Not Respond
                               ne843TrapRp1Rf 1.3.6.1.4.1.10520.2.1.3.35.78
Ringer Minor Fail
                               ne843TrapRp1Rpff 1.3.6.1.4.1.10520.2.1.3.35.79
Ringer Fan Fail
                               ne843TrapRp1Rprl 1.3.6.1.4.1.10520.2.1.3.35.80
Ringer Redundancy Loss
                               ne843TrapRp1Rpfj 1.3.6.1.4.1.10520.2.1.3.35.81
Ringer Major Fail
                               ne843TrapRp1Rpxj 1.3.6.1.4.1.10520.2.1.3.35.82
Ringer Major External Fault
                               ne843TrapRp1Rpxn 1.3.6.1.4.1.10520.2.1.3.35.83
Ringer Minor External Fault
                               ne843TrapRp1Rcdp 1.3.6.1.4.1.10520.2.1.3.35.84
Ringer ID Conflict
                               ne843TrapUserDefined 1.3.6.1.4.1.10520.2.1.3.35.85
This may be a user defined event, or a new controller event.
                               ne843TrapDc1Emd 1.3.6.1.4.1.10520.2.1.3.35.86
Energy Management Disabled
                               ne843TrapDc1Pfs 1.3.6.1.4.1.10520.2.1.3.35.87
Thermal Probe Fail Safe
                               ne843TrapDc1Rif 1.3.6.1.4.1.10520.2.1.3.35.88
Rectifier Internal Fault
                               ne843TrapDc1Lsf 1.3.6.1.4.1.10520.2.1.3.35.89
Load Share Fail
                               ne843TrapPs1Ax7 1.3.6.1.4.1.10520.2.1.3.35.90
Auxiliary Event 7
                               ne843TrapPs1Ax8 1.3.6.1.4.1.10520.2.1.3.35.91
Auxiliary Event 8
                               ne843TrapPs1Ax9 1.3.6.1.4.1.10520.2.1.3.35.92
Auxiliary Event 9
                               ne843TrapPs1Ax10 1.3.6.1.4.1.10520.2.1.3.35.93
Auxiliary Event 10
                               ne843TrapPs1Ax11 1.3.6.1.4.1.10520.2.1.3.35.94
Auxiliary Event 11
                               ne843TrapPs1Ax12 1.3.6.1.4.1.10520.2.1.3.35.95
Auxiliary Event 12
                               ne843TrapBr1Btla 1.3.6.1.4.1.10520.2.1.3.35.96
Low Battery Temperature
                               ne843TrapBr1Btvh 1.3.6.1.4.1.10520.2.1.3.35.97
Very High Battery Temperature
                               ne843TrapBr1Btvl 1.3.6.1.4.1.10520.2.1.3.35.98
Very Low Battery Temperature
                               ne843TrapGn1Gnr 1.3.6.1.4.1.10520.2.1.3.35.99
Generator Running
                               ne843TrapGn1Gnm 1.3.6.1.4.1.10520.2.1.3.35.100
Generator Maintenance Required
                               ne843TrapGn1Gnf 1.3.6.1.4.1.10520.2.1.3.35.101
Generator Fail
                               ne843TrapPs1Amtl 1.3.6.1.4.1.10520.2.1.3.35.102
Low Ambient Temperature
                               ne843TrapPs1Amth 1.3.6.1.4.1.10520.2.1.3.35.103
High Ambient Temperature
                               ne843TrapAco1Aac 1.3.6.1.4.1.10520.2.1.3.35.104
ACO Active
                               ne843TrapBr1Rba 1.3.6.1.4.1.10520.2.1.3.35.105
Reverse Battery
                               ne843TrapCp1Cin 1.3.6.1.4.1.10520.2.1.3.35.106
Converter Input Fail
                               ne843TrapDc1Bof 1.3.6.1.4.1.10520.2.1.3.35.107
Rectifier ORing FET Fault
                               ne843TrapDc1Sof 1.3.6.1.4.1.10520.2.1.3.35.108
Rectifier Shorted ORing FET
                               ne843TrapDc1Der 1.3.6.1.4.1.10520.2.1.3.35.109
Rectifier Under Voltage
                               ne843TrapGn1Gns 1.3.6.1.4.1.10520.2.1.3.35.110
Generator Start
                               ne843TrapIvp1Ilvi 1.3.6.1.4.1.10520.2.1.3.35.111
Inverter Low Input
                               ne843TrapIvp1Ihvi 1.3.6.1.4.1.10520.2.1.3.35.112
Inverter High Input
                               ne843TrapIvp1Ita 1.3.6.1.4.1.10520.2.1.3.35.113
Inverter High Temperature
                               ne843TrapIvp1If 1.3.6.1.4.1.10520.2.1.3.35.114
Inverter Fail
                               ne843TrapIvp1Ilv 1.3.6.1.4.1.10520.2.1.3.35.115
Inverter Low Output
                               ne843TrapIvp1Ifa 1.3.6.1.4.1.10520.2.1.3.35.116
Inverter Frequency Lock
                               ne843TrapIvp1Ihv 1.3.6.1.4.1.10520.2.1.3.35.117
Inverter High Output
                               ne843TrapIvp1Ida 1.3.6.1.4.1.10520.2.1.3.35.118
Inverter Distribution Alarm
                               ne843TrapIvp1Iof 1.3.6.1.4.1.10520.2.1.3.35.119
Inverter Output Fuse
                               ne843TrapIvp1Idid 1.3.6.1.4.1.10520.2.1.3.35.120
Inverter ID Conflict
                               ne843TrapIvp1Iirm 1.3.6.1.4.1.10520.2.1.3.35.121
Inverter High RMS Current
                               ne843TrapIvp1Iipk 1.3.6.1.4.1.10520.2.1.3.35.122
Inverter High Peak Current
                               ne843TrapIvp1Icf 1.3.6.1.4.1.10520.2.1.3.35.123
Inverter High Crest Factor
                               ne843TrapIvp1Mif 1.3.6.1.4.1.10520.2.1.3.35.124
Multiple Inverter Fail
                               ne843TrapIvp1Irls 1.3.6.1.4.1.10520.2.1.3.35.125
Inverter Redundancy Loss
                               ne843TrapDc1Pmf 1.3.6.1.4.1.10520.2.1.3.35.126
Probe Minimum Fail
                               ne843TrapPs1Crt 1.3.6.1.4.1.10520.2.1.3.35.127
Configuration Changed Reboot Required
                               ne843TrapIvp1Milv 1.3.6.1.4.1.10520.2.1.3.35.128
Multiple Inverter Low Input Voltage
                               ne843TrapDc1Faja 1.3.6.1.4.1.10520.2.1.3.35.129
Distribution Fuse A
                               ne843TrapDc1Buht 1.3.6.1.4.1.10520.2.1.3.35.130
Bus Hi Temp
                               ne843TrapDc1Buvht 1.3.6.1.4.1.10520.2.1.3.35.131
Bus Very Hi Temp
                               ne843TrapDc1Btha 1.3.6.1.4.1.10520.2.1.3.35.132
Batt Hi Temp
                               ne843TrapDc1Btvh 1.3.6.1.4.1.10520.2.1.3.35.133
Batt Very Hi Temp
                               ne843TrapDc1Btla 1.3.6.1.4.1.10520.2.1.3.35.134
Batt Low Temp
                               ne843TrapDc1Btvl 1.3.6.1.4.1.10520.2.1.3.35.135
Batt Very Low Temp
                               ne843TrapDc1Laht 1.3.6.1.4.1.10520.2.1.3.35.136
Local Amb. Hi Temp
                               ne843TrapDc1Lalt 1.3.6.1.4.1.10520.2.1.3.35.137
Local Amb. Low Temp
                               ne843TrapDc1Raht 1.3.6.1.4.1.10520.2.1.3.35.138
Remote Amb. Hi Temp
                               ne843TrapDc1Ravht 1.3.6.1.4.1.10520.2.1.3.35.139
Remote Amb. Very Hi Temp
                               ne843TrapDc1Ralt 1.3.6.1.4.1.10520.2.1.3.35.140
Remote Amb. Low Temp
                               ne843TrapDc1Vlva 1.3.6.1.4.1.10520.2.1.3.35.141
VA Power Loss
                               ne843TrapDc1Vlvb 1.3.6.1.4.1.10520.2.1.3.35.142
VB Power Loss
                               ne843TrapDc1Ovla 1.3.6.1.4.1.10520.2.1.3.35.143
IA Overload
                               ne843TrapDc1Ovlb 1.3.6.1.4.1.10520.2.1.3.35.144
IB Overload
                               ne843TrapDc1Pcaux 1.3.6.1.4.1.10520.2.1.3.35.145
PIC Auxiliary
                               ne843TrapDc1Slot 1.3.6.1.4.1.10520.2.1.3.35.146
PIC Slot
                               ne843TrapDc1Fajb 1.3.6.1.4.1.10520.2.1.3.35.147
Distribution Fuse B
                               ne843TrapDc1Smw 1.3.6.1.4.1.10520.2.1.3.35.148
Shunt Mis-wired
                               ne843TrapDc1Cca 1.3.6.1.4.1.10520.2.1.3.35.149
Circuit Assignment
                         ne843TrapInfo 1.3.6.1.4.1.10520.2.1.3.36
                               ne843TrapDesc 1.3.6.1.4.1.10520.2.1.3.36.1 displaystring no-access
Event Description
                               ne843TrapSev 1.3.6.1.4.1.10520.2.1.3.36.2 integer no-access
Event Severity Enumeration: 'major': 4, 'retire': 0, 'record': 1, 'warning': 2, 'critical': 5, 'minor': 3.
                               ne843TrapTime 1.3.6.1.4.1.10520.2.1.3.36.3 displaystring no-access
Time of Event
                               ne843TrapDate 1.3.6.1.4.1.10520.2.1.3.36.4 displaystring no-access
Date of Event
                               ne843TrapPath 1.3.6.1.4.1.10520.2.1.3.36.5 displaystring no-access
T1.317 Path of Event
                         ne843Retire 1.3.6.1.4.1.10520.2.1.3.37
                               ne843RetireDc1Amj 1.3.6.1.4.1.10520.2.1.3.37.1
Auxiliary Fuse Major
                               ne843RetireDc1Vsf 1.3.6.1.4.1.10520.2.1.3.37.2
Sense/Control Fuse
                               ne843RetireDc1Osa 1.3.6.1.4.1.10520.2.1.3.37.3
Open String
                               ne843RetireDc1Zid 1.3.6.1.4.1.10520.2.1.3.37.4
ID Not Configured
                               ne843RetireDc1Tpa 1.3.6.1.4.1.10520.2.1.3.37.5
Thermal Probe Alarm
                               ne843RetireDc1Vmf 1.3.6.1.4.1.10520.2.1.3.37.6
Voltage Module Fail
                               ne843RetireDc1Cma 1.3.6.1.4.1.10520.2.1.3.37.7
Minor Communication Failure
                               ne843RetireDc1Mcm 1.3.6.1.4.1.10520.2.1.3.37.8
Major Communication Failure
                               ne843RetireDc1Epo 1.3.6.1.4.1.10520.2.1.3.37.9
Emergency Power Off
                               ne843RetireDc1Icr 1.3.6.1.4.1.10520.2.1.3.37.10
Incompatible Rectifier
                               ne843RetireDc1Rfa 1.3.6.1.4.1.10520.2.1.3.37.11
Rectifier Fail
                               ne843RetireDc1Acf 1.3.6.1.4.1.10520.2.1.3.37.12
AC Fail
                               ne843RetireDc1Man 1.3.6.1.4.1.10520.2.1.3.37.13
Manual Off
                               ne843RetireDc1Did 1.3.6.1.4.1.10520.2.1.3.37.14
ID Conflict
                               ne843RetireDc1Clm 1.3.6.1.4.1.10520.2.1.3.37.15
Rectifier Current Limit
                               ne843RetireDc1Rfn 1.3.6.1.4.1.10520.2.1.3.37.16
Rectifier Fan Failure
                               ne843RetireDc1Vla 1.3.6.1.4.1.10520.2.1.3.37.17
Very Low Voltage
                               ne843RetireDc1Mfa 1.3.6.1.4.1.10520.2.1.3.37.18
Multiple Rectifier Fail
                               ne843RetireDc1Rtl 1.3.6.1.4.1.10520.2.1.3.37.19
Reserve Time Low
                               ne843RetireDc1Rrtl 1.3.6.1.4.1.10520.2.1.3.37.20
Real-time Reserve Time Low
                               ne843RetireDc1Rls 1.3.6.1.4.1.10520.2.1.3.37.21
Redundancy Loss
                               ne843RetireDc1Mman 1.3.6.1.4.1.10520.2.1.3.37.22
Multiple Manual Off
                               ne843RetireDc1Macf 1.3.6.1.4.1.10520.2.1.3.37.23
Multiple AC Failure
                               ne843RetireDc1Bda 1.3.6.1.4.1.10520.2.1.3.37.24
Battery On Discharge
                               ne843RetireDc1Hva 1.3.6.1.4.1.10520.2.1.3.37.25
High Voltage
                               ne843RetireDc1Hfv 1.3.6.1.4.1.10520.2.1.3.37.26
High Float Voltage
                               ne843RetirePs1Epr 1.3.6.1.4.1.10520.2.1.3.37.27
External Password Reset
                               ne843RetirePs1Pfd 1.3.6.1.4.1.10520.2.1.3.37.28
Passwords At Default
                               ne843RetirePs1Exl 1.3.6.1.4.1.10520.2.1.3.37.29
Excessive Login Attempts
                               ne843RetirePs1Bbl 1.3.6.1.4.1.10520.2.1.3.37.30
Memory Backup Battery Low
                               ne843RetirePs1Clc 1.3.6.1.4.1.10520.2.1.3.37.31
Clock Changed
                               ne843RetirePs1Stf 1.3.6.1.4.1.10520.2.1.3.37.32
Self Test Failed
                               ne843RetirePs1Pgi 1.3.6.1.4.1.10520.2.1.3.37.33
Program Line Invalid
                               ne843RetirePs1Cch 1.3.6.1.4.1.10520.2.1.3.37.34
Configuration Changed
                               ne843RetirePs1Hcl 1.3.6.1.4.1.10520.2.1.3.37.35
History Cleared
                               ne843RetirePs1Ax1 1.3.6.1.4.1.10520.2.1.3.37.36
Auxiliary Event 1
                               ne843RetirePs1Ax2 1.3.6.1.4.1.10520.2.1.3.37.37
Auxiliary Event 2
                               ne843RetirePs1Ax3 1.3.6.1.4.1.10520.2.1.3.37.38
Auxiliary Event 3
                               ne843RetirePs1Ax4 1.3.6.1.4.1.10520.2.1.3.37.39
Auxiliary Event 4
                               ne843RetirePs1Ax5 1.3.6.1.4.1.10520.2.1.3.37.40
Auxiliary Event 5
                               ne843RetirePs1Ax6 1.3.6.1.4.1.10520.2.1.3.37.41
Auxiliary Event 6
                               ne843RetirePs1Fan24 1.3.6.1.4.1.10520.2.1.3.37.42
24 V Fuse Minor
                               ne843RetirePs1Fan48 1.3.6.1.4.1.10520.2.1.3.37.43
48 V Fuse Minor
                               ne843RetirePs1Faj24 1.3.6.1.4.1.10520.2.1.3.37.44
24 V Fuse Major
                               ne843RetirePs1Faj48 1.3.6.1.4.1.10520.2.1.3.37.45
48 V Fuse Major
                               ne843RetireAt1Ata 1.3.6.1.4.1.10520.2.1.3.37.46
Alarm Test Active
                               ne843RetireAt1Atb 1.3.6.1.4.1.10520.2.1.3.37.47
Alarm Test Aborted
                               ne843RetireCp1Cfa 1.3.6.1.4.1.10520.2.1.3.37.48
Converter Fail
                               ne843RetireCp1Cfn 1.3.6.1.4.1.10520.2.1.3.37.49
Converter Fan Minor
                               ne843RetireCp1Cfj 1.3.6.1.4.1.10520.2.1.3.37.50
Converter Fan Major
                               ne843RetireCp1Dfa 1.3.6.1.4.1.10520.2.1.3.37.51
Distribution Fail
                               ne843RetireCp1Did 1.3.6.1.4.1.10520.2.1.3.37.52
ID Conflict
                               ne843RetireCp1Icc 1.3.6.1.4.1.10520.2.1.3.37.53
Incompatible Converter Alarm
                               ne843RetireCp1Mfa 1.3.6.1.4.1.10520.2.1.3.37.54
Multiple Converter Fail
                               ne843RetireCp1Hva 1.3.6.1.4.1.10520.2.1.3.37.55
Converter High Voltage Major
                               ne843RetireCp1Hfv 1.3.6.1.4.1.10520.2.1.3.37.56
Converter High Voltage Minor
                               ne843RetireCp1Vla 1.3.6.1.4.1.10520.2.1.3.37.57
Converter Very Low Voltage
                               ne843RetireCp1Rl 1.3.6.1.4.1.10520.2.1.3.37.58
Converter Redundancy Loss
                               ne843RetireBr1Bta 1.3.6.1.4.1.10520.2.1.3.37.59
Battery Test Active
                               ne843RetireBr1Bfa 1.3.6.1.4.1.10520.2.1.3.37.60
Battery Test Failed
                               ne843RetireBr1Scda 1.3.6.1.4.1.10520.2.1.3.37.61
Shorted Cell Detected
                               ne843RetireBr1Isda 1.3.6.1.4.1.10520.2.1.3.37.62
Imminent Shutdown
                               ne843RetireBr1Mdp 1.3.6.1.4.1.10520.2.1.3.37.63
Voltage Duplicate ID
                               ne843RetireBr1Mzd 1.3.6.1.4.1.10520.2.1.3.37.64
Voltage ID Not Configured
                               ne843RetireBr1Btha 1.3.6.1.4.1.10520.2.1.3.37.65
High Battery Temperature
                               ne843RetireCn1Cno 1.3.6.1.4.1.10520.2.1.3.37.66
Contactor Open
                               ne843RetireCn1Cnf 1.3.6.1.4.1.10520.2.1.3.37.67
Contactor Failed
                               ne843RetireCn2Cno 1.3.6.1.4.1.10520.2.1.3.37.68
Contactor Open
                               ne843RetireCn2Cnf 1.3.6.1.4.1.10520.2.1.3.37.69
Contactor Failed
                               ne843RetireCn3Cno 1.3.6.1.4.1.10520.2.1.3.37.70
Contactor Open
                               ne843RetireCn3Cnf 1.3.6.1.4.1.10520.2.1.3.37.71
Contactor Failed
                               ne843RetireCn4Cno 1.3.6.1.4.1.10520.2.1.3.37.72
Contactor Open
                               ne843RetireCn4Cnf 1.3.6.1.4.1.10520.2.1.3.37.73
Contactor Failed
                               ne843RetireCm1Cof 1.3.6.1.4.1.10520.2.1.3.37.74
Queue Overflow
                               ne843RetireCm1Cor 1.3.6.1.4.1.10520.2.1.3.37.75
Number Did Not Respond
                               ne843RetireCm1Nnc 1.3.6.1.4.1.10520.2.1.3.37.76
Number Not Configured
                               ne843RetirePo1Por 1.3.6.1.4.1.10520.2.1.3.37.77
Number Did Not Respond
                               ne843RetireRp1Rf 1.3.6.1.4.1.10520.2.1.3.37.78
Ringer Minor Fail
                               ne843RetireRp1Rpff 1.3.6.1.4.1.10520.2.1.3.37.79
Ringer Fan Fail
                               ne843RetireRp1Rprl 1.3.6.1.4.1.10520.2.1.3.37.80
Ringer Redundancy Loss
                               ne843RetireRp1Rpfj 1.3.6.1.4.1.10520.2.1.3.37.81
Ringer Major Fail
                               ne843RetireRp1Rpxj 1.3.6.1.4.1.10520.2.1.3.37.82
Ringer Major External Fault
                               ne843RetireRp1Rpxn 1.3.6.1.4.1.10520.2.1.3.37.83
Ringer Minor External Fault
                               ne843RetireRp1Rcdp 1.3.6.1.4.1.10520.2.1.3.37.84
Ringer ID Conflict
                               ne843RetireUserDefined 1.3.6.1.4.1.10520.2.1.3.37.85
This may be a user defined event, or a new controller event.
                               ne843RetireDc1Emd 1.3.6.1.4.1.10520.2.1.3.37.86
Energy Management Disabled
                               ne843RetireDc1Pfs 1.3.6.1.4.1.10520.2.1.3.37.87
Thermal Probe Fail Safe
                               ne843RetireDc1Rif 1.3.6.1.4.1.10520.2.1.3.37.88
Rectifier Internal Fault
                               ne843RetireDc1Lsf 1.3.6.1.4.1.10520.2.1.3.37.89
Load Share Fail
                               ne843RetirePs1Ax7 1.3.6.1.4.1.10520.2.1.3.37.90
Auxiliary Event 7
                               ne843RetirePs1Ax8 1.3.6.1.4.1.10520.2.1.3.37.91
Auxiliary Event 8
                               ne843RetirePs1Ax9 1.3.6.1.4.1.10520.2.1.3.37.92
Auxiliary Event 9
                               ne843RetirePs1Ax10 1.3.6.1.4.1.10520.2.1.3.37.93
Auxiliary Event 10
                               ne843RetirePs1Ax11 1.3.6.1.4.1.10520.2.1.3.37.94
Auxiliary Event 11
                               ne843RetirePs1Ax12 1.3.6.1.4.1.10520.2.1.3.37.95
Auxiliary Event 12
                               ne843RetireBr1Btla 1.3.6.1.4.1.10520.2.1.3.37.96
Low Battery Temperature
                               ne843RetireBr1Btvh 1.3.6.1.4.1.10520.2.1.3.37.97
Very High Battery Temperature
                               ne843RetireBr1Btvl 1.3.6.1.4.1.10520.2.1.3.37.98
Very Low Battery Temperature
                               ne843RetireGn1Gnr 1.3.6.1.4.1.10520.2.1.3.37.99
Generator Running
                               ne843RetireGn1Gnm 1.3.6.1.4.1.10520.2.1.3.37.100
Generator Maintenance Required
                               ne843RetireGn1Gnf 1.3.6.1.4.1.10520.2.1.3.37.101
Generator Fail
                               ne843RetirePs1Amtl 1.3.6.1.4.1.10520.2.1.3.37.102
Low Ambient Temperature
                               ne843RetirePs1Amth 1.3.6.1.4.1.10520.2.1.3.37.103
High Ambient Temperature
                               ne843RetireAco1Aac 1.3.6.1.4.1.10520.2.1.3.37.104
ACO Active
                               ne843RetireBr1Rba 1.3.6.1.4.1.10520.2.1.3.37.105
Reverse Battery
                               ne843RetireCp1Cin 1.3.6.1.4.1.10520.2.1.3.37.106
Converter Input Fail
                               ne843RetireDc1Bof 1.3.6.1.4.1.10520.2.1.3.37.107
Rectifier ORing FET Fault
                               ne843RetireDc1Sof 1.3.6.1.4.1.10520.2.1.3.37.108
Rectifier Shorted ORing FET
                               ne843RetireDc1Der 1.3.6.1.4.1.10520.2.1.3.37.109
Rectifier Under Voltage
                               ne843RetireGn1Gns 1.3.6.1.4.1.10520.2.1.3.37.110
Generator Start
                               ne843RetireIvp1Ilvi 1.3.6.1.4.1.10520.2.1.3.37.111
Inverter Low Input
                               ne843RetireIvp1Ihvi 1.3.6.1.4.1.10520.2.1.3.37.112
Inverter High Input
                               ne843RetireIvp1Ita 1.3.6.1.4.1.10520.2.1.3.37.113
Inverter High Temperature
                               ne843RetireIvp1If 1.3.6.1.4.1.10520.2.1.3.37.114
Inverter Fail
                               ne843RetireIvp1Ilv 1.3.6.1.4.1.10520.2.1.3.37.115
Inverter Low Output
                               ne843RetireIvp1Ifa 1.3.6.1.4.1.10520.2.1.3.37.116
Inverter Frequency Lock
                               ne843RetireIvp1Ihv 1.3.6.1.4.1.10520.2.1.3.37.117
Inverter High Output
                               ne843RetireIvp1Ida 1.3.6.1.4.1.10520.2.1.3.37.118
Inverter Distribution Alarm
                               ne843RetireIvp1Iof 1.3.6.1.4.1.10520.2.1.3.37.119
Inverter Output Fuse
                               ne843RetireIvp1Idid 1.3.6.1.4.1.10520.2.1.3.37.120
Inverter ID Conflict
                               ne843RetireIvp1Iirm 1.3.6.1.4.1.10520.2.1.3.37.121
Inverter High RMS Current
                               ne843RetireIvp1Iipk 1.3.6.1.4.1.10520.2.1.3.37.122
Inverter High Peak Current
                               ne843RetireIvp1Icf 1.3.6.1.4.1.10520.2.1.3.37.123
Inverter High Crest Factor
                               ne843RetireIvp1Mif 1.3.6.1.4.1.10520.2.1.3.37.124
Multiple Inverter Fail
                               ne843RetireIvp1Irls 1.3.6.1.4.1.10520.2.1.3.37.125
Inverter Redundancy Loss
                               ne843RetireDc1Pmf 1.3.6.1.4.1.10520.2.1.3.37.126
Probe Minimum Fail
                               ne843RetirePs1Crt 1.3.6.1.4.1.10520.2.1.3.37.127
Configuration Changed Reboot Required
                               ne843RetireIvp1Milv 1.3.6.1.4.1.10520.2.1.3.37.128
Multiple Inverter Low Input Voltage
                               ne843RetireDc1Faja 1.3.6.1.4.1.10520.2.1.3.37.129
Distribution Fuse A
                               ne843RetireDc1Buht 1.3.6.1.4.1.10520.2.1.3.37.130
Bus Hi Temp
                               ne843RetireDc1Buvht 1.3.6.1.4.1.10520.2.1.3.37.131
Bus Very Hi Temp
                               ne843RetireDc1Btha 1.3.6.1.4.1.10520.2.1.3.37.132
Batt Hi Temp
                               ne843RetireDc1Btvh 1.3.6.1.4.1.10520.2.1.3.37.133
Batt Very Hi Temp
                               ne843RetireDc1Btla 1.3.6.1.4.1.10520.2.1.3.37.134
Batt Low Temp
                               ne843RetireDc1Btvl 1.3.6.1.4.1.10520.2.1.3.37.135
Batt Very Low Temp
                               ne843RetireDc1Laht 1.3.6.1.4.1.10520.2.1.3.37.136
Local Amb. Hi Temp
                               ne843RetireDc1Lalt 1.3.6.1.4.1.10520.2.1.3.37.137
Local Amb. Low Temp
                               ne843RetireDc1Raht 1.3.6.1.4.1.10520.2.1.3.37.138
Remote Amb. Hi Temp
                               ne843RetireDc1Ravht 1.3.6.1.4.1.10520.2.1.3.37.139
Remote Amb. Very Hi Temp
                               ne843RetireDc1Ralt 1.3.6.1.4.1.10520.2.1.3.37.140
Remote Amb. Low Temp
                               ne843RetireDc1Vlva 1.3.6.1.4.1.10520.2.1.3.37.141
VA Power Loss
                               ne843RetireDc1Vlvb 1.3.6.1.4.1.10520.2.1.3.37.142
VB Power Loss
                               ne843RetireDc1Ovla 1.3.6.1.4.1.10520.2.1.3.37.143
IA Overload
                               ne843RetireDc1Ovlb 1.3.6.1.4.1.10520.2.1.3.37.144
IB Overload
                               ne843RetireDc1Pcaux 1.3.6.1.4.1.10520.2.1.3.37.145
PIC Auxiliary
                               ne843RetireDc1Slot 1.3.6.1.4.1.10520.2.1.3.37.146
PIC Slot
                               ne843RetireDc1Fajb 1.3.6.1.4.1.10520.2.1.3.37.147
Distribution Fuse B
                               ne843RetireDc1Smw 1.3.6.1.4.1.10520.2.1.3.37.148
Shunt Mis-wired
                               ne843RetireDc1Cca 1.3.6.1.4.1.10520.2.1.3.37.149
Circuit Assignment
                         ne843Acd1 1.3.6.1.4.1.10520.2.1.3.38
                               ne843Acd1Ide 1.3.6.1.4.1.10520.2.1.3.38.1 displaystring read-only
Identifier
                               ne843Acd1Des 1.3.6.1.4.1.10520.2.1.3.38.2 displaystring read-write
Description
                               ne843Acd1Brc 1.3.6.1.4.1.10520.2.1.3.38.3 displaystring read-only
Board Code
                               ne843Acd1Sn 1.3.6.1.4.1.10520.2.1.3.38.4 displaystring read-only
Serial Number
                               ne843Acd1Prd 1.3.6.1.4.1.10520.2.1.3.38.5 displaystring read-write
Phase 1 Description
                               ne843Acd1Psd 1.3.6.1.4.1.10520.2.1.3.38.6 displaystring read-write
Phase 2 Description
                               ne843Acd1Ptd 1.3.6.1.4.1.10520.2.1.3.38.7 displaystring read-write
Phase 3 Description
                               ne843Acd1Prv 1.3.6.1.4.1.10520.2.1.3.38.8 displaystring read-only
Phase 1 Voltage (Vrms)
                               ne843Acd1Psv 1.3.6.1.4.1.10520.2.1.3.38.9 displaystring read-only
Phase 2 Voltage (Vrms)
                               ne843Acd1Ptv 1.3.6.1.4.1.10520.2.1.3.38.10 displaystring read-only
Phase 3 Voltage (Vrms)
                               ne843Acd1Pra 1.3.6.1.4.1.10520.2.1.3.38.11 displaystring read-only
Phase 1 Current (Amps)
                               ne843Acd1Psa 1.3.6.1.4.1.10520.2.1.3.38.12 displaystring read-only
Phase 2 Current (Amps)
                               ne843Acd1Pta 1.3.6.1.4.1.10520.2.1.3.38.13 displaystring read-only
Phase 3 Current (Amps)
                               ne843Acd1Prf 1.3.6.1.4.1.10520.2.1.3.38.14 displaystring read-only
Phase 1 Frequency (Hz)
                               ne843Acd1Psf 1.3.6.1.4.1.10520.2.1.3.38.15 displaystring read-only
Phase 2 Frequency (Hz)
                               ne843Acd1Ptf 1.3.6.1.4.1.10520.2.1.3.38.16 displaystring read-only
Phase 3 Frequency (Hz)
                               ne843Acd1Prk 1.3.6.1.4.1.10520.2.1.3.38.17 displaystring read-only
Phase 1 Power (kW)
                               ne843Acd1Psk 1.3.6.1.4.1.10520.2.1.3.38.18 displaystring read-only
Phase 2 Power (kW)
                               ne843Acd1Ptk 1.3.6.1.4.1.10520.2.1.3.38.19 displaystring read-only
Phase 3 Power (kW)
                               ne843Acd1Syk 1.3.6.1.4.1.10520.2.1.3.38.20 displaystring read-only
Total Power (kW)
                               ne843Acd1Prx 1.3.6.1.4.1.10520.2.1.3.38.21 displaystring read-write
Phase 1 CTR
                               ne843Acd1Psx 1.3.6.1.4.1.10520.2.1.3.38.22 displaystring read-write
Phase 2 CTR
                               ne843Acd1Ptx 1.3.6.1.4.1.10520.2.1.3.38.23 displaystring read-write
Phase 3 CTR
                         ne843Gn1 1.3.6.1.4.1.10520.2.1.3.39
                               ne843Gn1Ide 1.3.6.1.4.1.10520.2.1.3.39.1 displaystring read-only
Identifier
                               ne843Gn1Des 1.3.6.1.4.1.10520.2.1.3.39.2 displaystring read-write
Description
                               ne843Gn1Rt 1.3.6.1.4.1.10520.2.1.3.39.3 displaystring read-write
Cumulative Runtime
                               ne843Gn1Trt 1.3.6.1.4.1.10520.2.1.3.39.4 displaystring read-only
Current Runtime
                               ne843Gn1Gnr 1.3.6.1.4.1.10520.2.1.3.39.5 displaystring read-only
Generator Running Value: Alarm report from GNR1
                               ne843Gn1Gnm 1.3.6.1.4.1.10520.2.1.3.39.6 displaystring read-only
Generator Maintenance Required Value: Alarm report from GNM1
                               ne843Gn1Gnf 1.3.6.1.4.1.10520.2.1.3.39.7 displaystring read-only
Generator Fail Value: Alarm report from GNF1
                               ne843Gn1Clt 1.3.6.1.4.1.10520.2.1.3.39.8 integer32 read-write
Current Limit Threshold (Amps)
                               ne843Gn1Tv 1.3.6.1.4.1.10520.2.1.3.39.9 integer32 read-write
Start Voltage
                               ne843Gn1Tvd 1.3.6.1.4.1.10520.2.1.3.39.10 displaystring read-write
Start Voltage Delay
                               ne843Gn1Tp 1.3.6.1.4.1.10520.2.1.3.39.11 integer32 read-write
Start Percent of Charge
                               ne843Gn1Tpd 1.3.6.1.4.1.10520.2.1.3.39.12 displaystring read-write
Start POC Delay
                               ne843Gn1Tct 1.3.6.1.4.1.10520.2.1.3.39.13 integer32 read-write
Start Cooling (ambient) Temperature (C)
                               ne843Gn1Tctd 1.3.6.1.4.1.10520.2.1.3.39.14 displaystring read-write
Start Cooling Temperature Delay
                               ne843Gn1Tht 1.3.6.1.4.1.10520.2.1.3.39.15 integer32 read-write
Start Heating (ambient) Temperature (C)
                               ne843Gn1Thtd 1.3.6.1.4.1.10520.2.1.3.39.16 displaystring read-write
Start Heating Temperature Delay
                               ne843Gn1Pv 1.3.6.1.4.1.10520.2.1.3.39.17 integer32 read-write
Stop Voltage
                               ne843Gn1Pvd 1.3.6.1.4.1.10520.2.1.3.39.18 displaystring read-write
Stop Voltage Delay
                               ne843Gn1Pi 1.3.6.1.4.1.10520.2.1.3.39.19 integer32 read-write
Stop Current
                               ne843Gn1Pid 1.3.6.1.4.1.10520.2.1.3.39.20 displaystring read-write
Stop Current Delay
                               ne843Gn1Pp 1.3.6.1.4.1.10520.2.1.3.39.21 integer32 read-write
Stop Percent of Charge
                               ne843Gn1Ppd 1.3.6.1.4.1.10520.2.1.3.39.22 displaystring read-write
Stop POC Delay
                               ne843Gn1Pct 1.3.6.1.4.1.10520.2.1.3.39.23 integer32 read-write
Stop Cooling (ambient) Temperature (C)
                               ne843Gn1Pctd 1.3.6.1.4.1.10520.2.1.3.39.24 displaystring read-write
Stop Cooling Temperature Delay
                               ne843Gn1Pht 1.3.6.1.4.1.10520.2.1.3.39.25 integer32 read-write
Stop Heating (ambient) Temperature (C)
                               ne843Gn1Phtd 1.3.6.1.4.1.10520.2.1.3.39.26 displaystring read-write
Stop Heating Temperature Delay
                               ne843Gn1Mrt 1.3.6.1.4.1.10520.2.1.3.39.27 displaystring read-write
Mininum Run Time
                               ne843Gn1Tve 1.3.6.1.4.1.10520.2.1.3.39.28 integer read-write
Start Voltage Enable Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                               ne843Gn1Tpe 1.3.6.1.4.1.10520.2.1.3.39.29 integer read-write
Start Percent of Charge Enable Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                               ne843Gn1Cte 1.3.6.1.4.1.10520.2.1.3.39.30 integer read-write
Start Cooling Temperatuer Enable Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                               ne843Gn1Hte 1.3.6.1.4.1.10520.2.1.3.39.31 integer read-write
Start Heating Temperatuer Enable Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                               ne843Gn1Pve 1.3.6.1.4.1.10520.2.1.3.39.32 integer read-write
Stop Voltage Enable Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                               ne843Gn1Pie 1.3.6.1.4.1.10520.2.1.3.39.33 integer read-write
Stop Current Enable Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                               ne843Gn1Ppe 1.3.6.1.4.1.10520.2.1.3.39.34 integer read-write
Stop Percent of Charge Enable Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                               ne843Gn1Nv 1.3.6.1.4.1.10520.2.1.3.39.35 integer32 read-write
Nominal Output Voltage
                               ne843Gn1Nva 1.3.6.1.4.1.10520.2.1.3.39.36 integer32 read-write
Nominal Output Power
                               ne843Gn1Ode 1.3.6.1.4.1.10520.2.1.3.39.37 integer read-write
Manual on Duration Enable Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                               ne843Gn1Odr 1.3.6.1.4.1.10520.2.1.3.39.38 displaystring read-write
Manual on Duration
                               ne843Gn1Ocd 1.3.6.1.4.1.10520.2.1.3.39.39 displaystring read-only
Manual on Duration countdown
                               ne843Gn1Gns 1.3.6.1.4.1.10520.2.1.3.39.40 displaystring read-only
Generator Start Value: Alarm report from GNS1
                               ne843Gn1Aue 1.3.6.1.4.1.10520.2.1.3.39.41 integer read-write
Auto Mode Enable Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                               ne843Gn1Mod 1.3.6.1.4.1.10520.2.1.3.39.42 displaystring read-write
Auto Mode Values: OFF, ON, AUTO
                               ne843Gn1Stt 1.3.6.1.4.1.10520.2.1.3.39.43 displaystring read-only
State
                         ne843BatTable 1.3.6.1.4.1.10520.2.1.3.40 no-access
Table of all Battery Section data
                               ne843BatEntry 1.3.6.1.4.1.10520.2.1.3.40.1 no-access
Entry of information for one Battery Section
                                   ne843BatEntryIndex 1.3.6.1.4.1.10520.2.1.3.40.1.1 integer read-only
Table Index
                                   ne843BatEntryIde 1.3.6.1.4.1.10520.2.1.3.40.1.2 displaystring read-only
Identifier
                                   ne843BatEntryDes 1.3.6.1.4.1.10520.2.1.3.40.1.3 displaystring read-write
Description
                                   ne843BatEntryCon 1.3.6.1.4.1.10520.2.1.3.40.1.4 displaystring read-write
Contactor
                                   ne843BatEntryStt 1.3.6.1.4.1.10520.2.1.3.40.1.5 displaystring read-only
State
                                   ne843BatEntryNst 1.3.6.1.4.1.10520.2.1.3.40.1.6 displaystring read-write
Number of Strings
                                   ne843BatEntryBty 1.3.6.1.4.1.10520.2.1.3.40.1.7 displaystring read-only
Battery Type
                                   ne843BatEntryCap 1.3.6.1.4.1.10520.2.1.3.40.1.8 displaystring read-only
Capacity
                                   ne843BatEntryDat 1.3.6.1.4.1.10520.2.1.3.40.1.9 displaystring read-only
Install Date
                                   ne843BatEntryMpv 1.3.6.1.4.1.10520.2.1.3.40.1.10 displaystring read-only
Midtstring Voltage (Volts)
                                   ne843BatEntryAdc 1.3.6.1.4.1.10520.2.1.3.40.1.11 displaystring read-only
Current (Amps)
                         ne843Eco1 1.3.6.1.4.1.10520.2.1.3.41
                               ne843Eco1Ide 1.3.6.1.4.1.10520.2.1.3.41.1 displaystring read-only
Identifier
                               ne843Eco1Des 1.3.6.1.4.1.10520.2.1.3.41.2 displaystring read-write
Description
                               ne843Eco1Sofs 1.3.6.1.4.1.10520.2.1.3.41.3 displaystring read-write
Solar Rectifier Offset
                               ne843Eco1Ntrd 1.3.6.1.4.1.10520.2.1.3.41.4 displaystring read-only
Normal Rectifier Drain
                               ne843Eco1Strd 1.3.6.1.4.1.10520.2.1.3.41.5 displaystring read-only
Solar Rectifier Drain
                               ne843Eco1Nkwh 1.3.6.1.4.1.10520.2.1.3.41.6 displaystring read-only
Normal kWh
                               ne843Eco1Skwh 1.3.6.1.4.1.10520.2.1.3.41.7 displaystring read-only
Solar kWh
                               ne843Eco1Ncap 1.3.6.1.4.1.10520.2.1.3.41.8 displaystring read-only
Normal Capacity
                               ne843Eco1Nocap 1.3.6.1.4.1.10520.2.1.3.41.9 displaystring read-only
Normal Online Capacity
                         ne843Ivp1 1.3.6.1.4.1.10520.2.1.3.42
                               ne843Ivp1Ide 1.3.6.1.4.1.10520.2.1.3.42.1 displaystring read-only
Identifier
                               ne843Ivp1Des 1.3.6.1.4.1.10520.2.1.3.42.2 displaystring read-write
Description
                               ne843Ivp1Cap 1.3.6.1.4.1.10520.2.1.3.42.3 integer32 read-only
Total Installed Inverter Capacity (Amps)
                               ne843Ivp1Irm 1.3.6.1.4.1.10520.2.1.3.42.4 integer32 read-only
RMS Current
                               ne843Ivp1Vac 1.3.6.1.4.1.10520.2.1.3.42.5 integer32 read-only
AC Output voltage
                               ne843Ivp1Adc 1.3.6.1.4.1.10520.2.1.3.42.6 integer32 read-only
DC Current
                               ne843Ivp1Vdc 1.3.6.1.4.1.10520.2.1.3.42.7 integer32 read-only
DC Voltage
                               ne843Ivp1Frq 1.3.6.1.4.1.10520.2.1.3.42.8 integer32 read-only
Frequency
                               ne843Ivp1Lst 1.3.6.1.4.1.10520.2.1.3.42.9 integer32 read-only
Load Share Target Percentage
                               ne843Ivp1Ste 1.3.6.1.4.1.10520.2.1.3.42.10 integer read-write
Standby Enabled Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                               ne843Ivp1Rlse 1.3.6.1.4.1.10520.2.1.3.42.11 integer read-write
Redundancy Loss Enabled Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                               ne843Ivp1Dth 1.3.6.1.4.1.10520.2.1.3.42.12 integer32 read-write
Low Voltage Disconnect Threshold
                               ne843Ivp1Rth 1.3.6.1.4.1.10520.2.1.3.42.13 integer32 read-write
Low Voltage Reconnect Threshold
                               ne843Ivp1Lvd 1.3.6.1.4.1.10520.2.1.3.42.14 integer read-write
Low Voltage Disconnect Enabled Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                               ne843Ivp1Hce 1.3.6.1.4.1.10520.2.1.3.42.15 integer read-write
Hi Crest Factor Enabled Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                               ne843Ivp1Hipe 1.3.6.1.4.1.10520.2.1.3.42.16 integer read-write
Hi IPeak Current Enabled Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                               ne843Ivp1Hrme 1.3.6.1.4.1.10520.2.1.3.42.17 integer read-write
Hi IRMS Currrent Enabled Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                               ne843Ivp1Ilvi 1.3.6.1.4.1.10520.2.1.3.42.18 displaystring read-only
Inverter Low Input Value: Alarm report from ILVI1
                               ne843Ivp1Ihvi 1.3.6.1.4.1.10520.2.1.3.42.19 displaystring read-only
Inverter High Input Value: Alarm report from IHVI1
                               ne843Ivp1Ita 1.3.6.1.4.1.10520.2.1.3.42.20 displaystring read-only
Inverter High Temperature Value: Alarm report from ITA1
                               ne843Ivp1If 1.3.6.1.4.1.10520.2.1.3.42.21 displaystring read-only
Inverter Fail Value: Alarm report from IF1
                               ne843Ivp1Ilv 1.3.6.1.4.1.10520.2.1.3.42.22 displaystring read-only
Inverter Low Output Value: Alarm report from ILV1
                               ne843Ivp1Ifa 1.3.6.1.4.1.10520.2.1.3.42.23 displaystring read-only
Inverter Frequency Lock Value: Alarm report from IFA1
                               ne843Ivp1Ihv 1.3.6.1.4.1.10520.2.1.3.42.24 displaystring read-only
Inverter High Output Value: Alarm report from IHV1
                               ne843Ivp1Ida 1.3.6.1.4.1.10520.2.1.3.42.25 displaystring read-only
Inverter Distribution Alarm Value: Alarm report from IDA1
                               ne843Ivp1Iof 1.3.6.1.4.1.10520.2.1.3.42.26 displaystring read-only
Inverter Output Fuse Value: Alarm report from IOF1
                               ne843Ivp1Idid 1.3.6.1.4.1.10520.2.1.3.42.27 displaystring read-only
Inverter ID Conflict Value: Alarm report from IDID1
                               ne843Ivp1Iirm 1.3.6.1.4.1.10520.2.1.3.42.28 displaystring read-only
Inverter High RMS Current Value: Alarm report from IIRM1
                               ne843Ivp1Iipk 1.3.6.1.4.1.10520.2.1.3.42.29 displaystring read-only
Inverter High Peak Current Value: Alarm report from IIPK1
                               ne843Ivp1Icf 1.3.6.1.4.1.10520.2.1.3.42.30 displaystring read-only
Inverter High Crest Factor Value: Alarm report from ICF1
                               ne843Ivp1Mif 1.3.6.1.4.1.10520.2.1.3.42.31 displaystring read-only
Multiple Inverter Fail Value: Alarm report from MIF1
                               ne843Ivp1Irls 1.3.6.1.4.1.10520.2.1.3.42.32 displaystring read-only
Inverter Redundancy Loss Value: Alarm report from IRLS1
                               ne843Ivp1Milv 1.3.6.1.4.1.10520.2.1.3.42.33 displaystring read-only
Multiple Inverter Low Input Voltage Value: Alarm report from MILV1
                         ne843InvTable 1.3.6.1.4.1.10520.2.1.3.43 no-access
Table of all Inverter data
                               ne843InvEntry 1.3.6.1.4.1.10520.2.1.3.43.1 no-access
Entry of information for one Inverter
                                   ne843InvEntryIndex 1.3.6.1.4.1.10520.2.1.3.43.1.1 integer read-only
Table Index
                                   ne843InvEntryIde 1.3.6.1.4.1.10520.2.1.3.43.1.2 displaystring read-only
Identifier
                                   ne843InvEntryDes 1.3.6.1.4.1.10520.2.1.3.43.1.3 displaystring read-write
Description
                                   ne843InvEntryTyp 1.3.6.1.4.1.10520.2.1.3.43.1.4 displaystring read-write
Type
                                   ne843InvEntrySn 1.3.6.1.4.1.10520.2.1.3.43.1.5 displaystring read-only
Serial Number
                                   ne843InvEntryAdc 1.3.6.1.4.1.10520.2.1.3.43.1.6 integer32 read-only
DC Current (Amps)
                                   ne843InvEntryVdc 1.3.6.1.4.1.10520.2.1.3.43.1.7 integer32 read-only
DC Voltage
                                   ne843InvEntryVac 1.3.6.1.4.1.10520.2.1.3.43.1.8 integer32 read-only
AC Voltage (Volts)
                                   ne843InvEntryStt 1.3.6.1.4.1.10520.2.1.3.43.1.9 displaystring read-write
State Values: ON, OFF, STANDBY, VACANT
                                   ne843InvEntryCap 1.3.6.1.4.1.10520.2.1.3.43.1.10 integer32 read-only
Capacity (Amps)
                                   ne843InvEntryCva 1.3.6.1.4.1.10520.2.1.3.43.1.11 integer32 read-only
Capacity in VA
                                   ne843InvEntryIpk 1.3.6.1.4.1.10520.2.1.3.43.1.12 integer32 read-only
Peak Current
                                   ne843InvEntryIrm 1.3.6.1.4.1.10520.2.1.3.43.1.13 integer32 read-only
RMS Current
                                   ne843InvEntryFrq 1.3.6.1.4.1.10520.2.1.3.43.1.14 integer32 read-only
Output Frequency
                                   ne843InvEntryCf 1.3.6.1.4.1.10520.2.1.3.43.1.15 integer32 read-only
Crest Factor
                                   ne843InvEntryPwr 1.3.6.1.4.1.10520.2.1.3.43.1.16 integer32 read-only
Output Power
                                   ne843InvEntryVnom 1.3.6.1.4.1.10520.2.1.3.43.1.17 integer32 read-only
Nominal Output Voltage
                                   ne843InvEntryNcl 1.3.6.1.4.1.10520.2.1.3.43.1.18 integer read-write
Non-Critical Load (for LVD) Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                                   ne843InvEntryIlvi 1.3.6.1.4.1.10520.2.1.3.43.1.19 displaystring read-only
Low Voltage Input
                                   ne843InvEntryIta 1.3.6.1.4.1.10520.2.1.3.43.1.20 displaystring read-only
Temperature Alarm
                                   ne843InvEntryIf 1.3.6.1.4.1.10520.2.1.3.43.1.21 displaystring read-only
Inverter Fail
                                   ne843InvEntryIlv 1.3.6.1.4.1.10520.2.1.3.43.1.22 displaystring read-only
Low Output Voltage
                                   ne843InvEntryIfa 1.3.6.1.4.1.10520.2.1.3.43.1.23 displaystring read-only
Inverter Frequency Lock Fail
                                   ne843InvEntryDid 1.3.6.1.4.1.10520.2.1.3.43.1.24 displaystring read-only
ID Conflict
                                   ne843InvEntryIcmf 1.3.6.1.4.1.10520.2.1.3.43.1.25 displaystring read-only
Communication Failure
                                   ne843InvEntryIcf 1.3.6.1.4.1.10520.2.1.3.43.1.26 displaystring read-only
Hi Crest Factor Status
                                   ne843InvEntryIda 1.3.6.1.4.1.10520.2.1.3.43.1.27 displaystring read-only
Distribution Alarm Status
                                   ne843InvEntryIhv 1.3.6.1.4.1.10520.2.1.3.43.1.28 displaystring read-only
High Output Status
                                   ne843InvEntryIhvi 1.3.6.1.4.1.10520.2.1.3.43.1.29 displaystring read-only
High Input Status
                                   ne843InvEntryIipk 1.3.6.1.4.1.10520.2.1.3.43.1.30 displaystring read-only
High IPeak Status
                                   ne843InvEntryIirm 1.3.6.1.4.1.10520.2.1.3.43.1.31 displaystring read-only
High IRMS Status
                                   ne843InvEntryIof 1.3.6.1.4.1.10520.2.1.3.43.1.32 displaystring read-only
Output Fuse Status
                                   ne843InvEntryIlvi1 1.3.6.1.4.1.10520.2.1.3.43.1.33 integer read-only
Low Voltage Input Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                                   ne843InvEntryIta1 1.3.6.1.4.1.10520.2.1.3.43.1.34 integer read-only
Temperature Alarm Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                                   ne843InvEntryIf1 1.3.6.1.4.1.10520.2.1.3.43.1.35 integer read-only
Inverter Fail Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                                   ne843InvEntryIlv1 1.3.6.1.4.1.10520.2.1.3.43.1.36 integer read-only
Low Output Voltage Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                                   ne843InvEntryIfa1 1.3.6.1.4.1.10520.2.1.3.43.1.37 integer read-only
Inverter Frequency Lock Fail Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                                   ne843InvEntryDid1 1.3.6.1.4.1.10520.2.1.3.43.1.38 integer read-only
ID Conflict Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                                   ne843InvEntryIcmf1 1.3.6.1.4.1.10520.2.1.3.43.1.39 integer read-only
Communication Failure Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                                   ne843InvEntryIcf1 1.3.6.1.4.1.10520.2.1.3.43.1.40 integer read-only
Hi Crest Factor Status Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                                   ne843InvEntryIda1 1.3.6.1.4.1.10520.2.1.3.43.1.41 integer read-only
Distribution Alarm Status Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                                   ne843InvEntryIhv1 1.3.6.1.4.1.10520.2.1.3.43.1.42 integer read-only
High Output Status Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                                   ne843InvEntryIhvi1 1.3.6.1.4.1.10520.2.1.3.43.1.43 integer read-only
High Input Status Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                                   ne843InvEntryIipk1 1.3.6.1.4.1.10520.2.1.3.43.1.44 integer read-only
High IPeak Status Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                                   ne843InvEntryIirm1 1.3.6.1.4.1.10520.2.1.3.43.1.45 integer read-only
High IRMS Status Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                                   ne843InvEntryIof1 1.3.6.1.4.1.10520.2.1.3.43.1.46 integer read-only
Output Fuse Status Values: inactive(0), active(1) Enumeration: 'active': 1, 'inactive': 0.
                         ne843Rpt1 1.3.6.1.4.1.10520.2.1.3.44
                               ne843Rpt1Ide 1.3.6.1.4.1.10520.2.1.3.44.1 displaystring read-only
Identifier
                               ne843Rpt1Des 1.3.6.1.4.1.10520.2.1.3.44.2 displaystring read-write
Description
                               ne843Rpt1Ena 1.3.6.1.4.1.10520.2.1.3.44.3 integer read-write
Enable Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                               ne843Rpt1Int 1.3.6.1.4.1.10520.2.1.3.44.4 integer32 read-write
Interval (minutes)
                               ne843Rpt1D001 1.3.6.1.4.1.10520.2.1.3.44.5 displaystring read-write
Parameter 1
                               ne843Rpt1D002 1.3.6.1.4.1.10520.2.1.3.44.6 displaystring read-write
Parameter 2
                               ne843Rpt1D003 1.3.6.1.4.1.10520.2.1.3.44.7 displaystring read-write
Parameter 3
                               ne843Rpt1D004 1.3.6.1.4.1.10520.2.1.3.44.8 displaystring read-write
Parameter 4
                               ne843Rpt1D005 1.3.6.1.4.1.10520.2.1.3.44.9 displaystring read-write
Parameter 5
                               ne843Rpt1D006 1.3.6.1.4.1.10520.2.1.3.44.10 displaystring read-write
Parameter 6
                               ne843Rpt1D007 1.3.6.1.4.1.10520.2.1.3.44.11 displaystring read-write
Parameter 7
                               ne843Rpt1D008 1.3.6.1.4.1.10520.2.1.3.44.12 displaystring read-write
Parameter 8
                               ne843Rpt1D009 1.3.6.1.4.1.10520.2.1.3.44.13 displaystring read-write
Parameter 9
                               ne843Rpt1D010 1.3.6.1.4.1.10520.2.1.3.44.14 displaystring read-write
Parameter 10
                               ne843Rpt1D011 1.3.6.1.4.1.10520.2.1.3.44.15 displaystring read-write
Parameter 11
                               ne843Rpt1D012 1.3.6.1.4.1.10520.2.1.3.44.16 displaystring read-write
Parameter 12
                               ne843Rpt1D013 1.3.6.1.4.1.10520.2.1.3.44.17 displaystring read-write
Parameter 13
                               ne843Rpt1D014 1.3.6.1.4.1.10520.2.1.3.44.18 displaystring read-write
Parameter 14
                               ne843Rpt1D015 1.3.6.1.4.1.10520.2.1.3.44.19 displaystring read-write
Parameter 15
                               ne843Rpt1D016 1.3.6.1.4.1.10520.2.1.3.44.20 displaystring read-write
Parameter 16
                               ne843Rpt1D017 1.3.6.1.4.1.10520.2.1.3.44.21 displaystring read-write
Parameter 17
                               ne843Rpt1D018 1.3.6.1.4.1.10520.2.1.3.44.22 displaystring read-write
Parameter 18
                               ne843Rpt1D019 1.3.6.1.4.1.10520.2.1.3.44.23 displaystring read-write
Parameter 19
                               ne843Rpt1D020 1.3.6.1.4.1.10520.2.1.3.44.24 displaystring read-write
Parameter 20
                               ne843Rpt1D021 1.3.6.1.4.1.10520.2.1.3.44.25 displaystring read-write
Parameter 21
                               ne843Rpt1D022 1.3.6.1.4.1.10520.2.1.3.44.26 displaystring read-write
Parameter 22
                               ne843Rpt1D023 1.3.6.1.4.1.10520.2.1.3.44.27 displaystring read-write
Parameter 23
                               ne843Rpt1D024 1.3.6.1.4.1.10520.2.1.3.44.28 displaystring read-write
Parameter 24
                               ne843Rpt1D025 1.3.6.1.4.1.10520.2.1.3.44.29 displaystring read-write
Parameter 25
                               ne843Rpt1D026 1.3.6.1.4.1.10520.2.1.3.44.30 displaystring read-write
Parameter 26
                               ne843Rpt1D027 1.3.6.1.4.1.10520.2.1.3.44.31 displaystring read-write
Parameter 27
                               ne843Rpt1D028 1.3.6.1.4.1.10520.2.1.3.44.32 displaystring read-write
Parameter 28
                               ne843Rpt1D029 1.3.6.1.4.1.10520.2.1.3.44.33 displaystring read-write
Parameter 29
                               ne843Rpt1D030 1.3.6.1.4.1.10520.2.1.3.44.34 displaystring read-write
Parameter 30
                               ne843Rpt1D031 1.3.6.1.4.1.10520.2.1.3.44.35 displaystring read-write
Parameter 31
                               ne843Rpt1D032 1.3.6.1.4.1.10520.2.1.3.44.36 displaystring read-write
Parameter 32
                               ne843Rpt1D033 1.3.6.1.4.1.10520.2.1.3.44.37 displaystring read-write
Parameter 33
                               ne843Rpt1D034 1.3.6.1.4.1.10520.2.1.3.44.38 displaystring read-write
Parameter 34
                               ne843Rpt1D035 1.3.6.1.4.1.10520.2.1.3.44.39 displaystring read-write
Parameter 35
                               ne843Rpt1D036 1.3.6.1.4.1.10520.2.1.3.44.40 displaystring read-write
Parameter 36
                               ne843Rpt1D037 1.3.6.1.4.1.10520.2.1.3.44.41 displaystring read-write
Parameter 37
                               ne843Rpt1D038 1.3.6.1.4.1.10520.2.1.3.44.42 displaystring read-write
Parameter 38
                               ne843Rpt1D039 1.3.6.1.4.1.10520.2.1.3.44.43 displaystring read-write
Parameter 39
                               ne843Rpt1D040 1.3.6.1.4.1.10520.2.1.3.44.44 displaystring read-write
Parameter 40
                               ne843Rpt1D041 1.3.6.1.4.1.10520.2.1.3.44.45 displaystring read-write
Parameter 41
                               ne843Rpt1D042 1.3.6.1.4.1.10520.2.1.3.44.46 displaystring read-write
Parameter 42
                               ne843Rpt1D043 1.3.6.1.4.1.10520.2.1.3.44.47 displaystring read-write
Parameter 43
                               ne843Rpt1D044 1.3.6.1.4.1.10520.2.1.3.44.48 displaystring read-write
Parameter 44
                               ne843Rpt1D045 1.3.6.1.4.1.10520.2.1.3.44.49 displaystring read-write
Parameter 45
                               ne843Rpt1D046 1.3.6.1.4.1.10520.2.1.3.44.50 displaystring read-write
Parameter 46
                               ne843Rpt1D047 1.3.6.1.4.1.10520.2.1.3.44.51 displaystring read-write
Parameter 47
                               ne843Rpt1D048 1.3.6.1.4.1.10520.2.1.3.44.52 displaystring read-write
Parameter 48
                               ne843Rpt1D049 1.3.6.1.4.1.10520.2.1.3.44.53 displaystring read-write
Parameter 49
                               ne843Rpt1D050 1.3.6.1.4.1.10520.2.1.3.44.54 displaystring read-write
Parameter 40
                               ne843Rpt1D051 1.3.6.1.4.1.10520.2.1.3.44.55 displaystring read-write
Parameter 51
                               ne843Rpt1D052 1.3.6.1.4.1.10520.2.1.3.44.56 displaystring read-write
Parameter 52
                               ne843Rpt1D053 1.3.6.1.4.1.10520.2.1.3.44.57 displaystring read-write
Parameter 53
                               ne843Rpt1D054 1.3.6.1.4.1.10520.2.1.3.44.58 displaystring read-write
Parameter 54
                               ne843Rpt1D055 1.3.6.1.4.1.10520.2.1.3.44.59 displaystring read-write
Parameter 55
                               ne843Rpt1D056 1.3.6.1.4.1.10520.2.1.3.44.60 displaystring read-write
Parameter 56
                               ne843Rpt1D057 1.3.6.1.4.1.10520.2.1.3.44.61 displaystring read-write
Parameter 57
                               ne843Rpt1D058 1.3.6.1.4.1.10520.2.1.3.44.62 displaystring read-write
Parameter 58
                               ne843Rpt1D059 1.3.6.1.4.1.10520.2.1.3.44.63 displaystring read-write
Parameter 59
                               ne843Rpt1D060 1.3.6.1.4.1.10520.2.1.3.44.64 displaystring read-write
Parameter 60
                               ne843Rpt1D061 1.3.6.1.4.1.10520.2.1.3.44.65 displaystring read-write
Parameter 61
                               ne843Rpt1D062 1.3.6.1.4.1.10520.2.1.3.44.66 displaystring read-write
Parameter 62
                               ne843Rpt1D063 1.3.6.1.4.1.10520.2.1.3.44.67 displaystring read-write
Parameter 63
                               ne843Rpt1D064 1.3.6.1.4.1.10520.2.1.3.44.68 displaystring read-write
Parameter 64
                               ne843Rpt1D065 1.3.6.1.4.1.10520.2.1.3.44.69 displaystring read-write
Parameter 65
                               ne843Rpt1D066 1.3.6.1.4.1.10520.2.1.3.44.70 displaystring read-write
Parameter 66
                               ne843Rpt1D067 1.3.6.1.4.1.10520.2.1.3.44.71 displaystring read-write
Parameter 67
                               ne843Rpt1D068 1.3.6.1.4.1.10520.2.1.3.44.72 displaystring read-write
Parameter 68
                               ne843Rpt1D069 1.3.6.1.4.1.10520.2.1.3.44.73 displaystring read-write
Parameter 69
                               ne843Rpt1D070 1.3.6.1.4.1.10520.2.1.3.44.74 displaystring read-write
Parameter 70
                               ne843Rpt1D071 1.3.6.1.4.1.10520.2.1.3.44.75 displaystring read-write
Parameter 71
                               ne843Rpt1D072 1.3.6.1.4.1.10520.2.1.3.44.76 displaystring read-write
Parameter 72
                               ne843Rpt1D073 1.3.6.1.4.1.10520.2.1.3.44.77 displaystring read-write
Parameter 73
                               ne843Rpt1D074 1.3.6.1.4.1.10520.2.1.3.44.78 displaystring read-write
Parameter 74
                               ne843Rpt1D075 1.3.6.1.4.1.10520.2.1.3.44.79 displaystring read-write
Parameter 75
                               ne843Rpt1D076 1.3.6.1.4.1.10520.2.1.3.44.80 displaystring read-write
Parameter 76
                               ne843Rpt1D077 1.3.6.1.4.1.10520.2.1.3.44.81 displaystring read-write
Parameter 77
                               ne843Rpt1D078 1.3.6.1.4.1.10520.2.1.3.44.82 displaystring read-write
Parameter 78
                               ne843Rpt1D079 1.3.6.1.4.1.10520.2.1.3.44.83 displaystring read-write
Parameter 79
                               ne843Rpt1D080 1.3.6.1.4.1.10520.2.1.3.44.84 displaystring read-write
Parameter 80
                               ne843Rpt1D081 1.3.6.1.4.1.10520.2.1.3.44.85 displaystring read-write
Parameter 81
                               ne843Rpt1D082 1.3.6.1.4.1.10520.2.1.3.44.86 displaystring read-write
Parameter 82
                               ne843Rpt1D083 1.3.6.1.4.1.10520.2.1.3.44.87 displaystring read-write
Parameter 83
                               ne843Rpt1D084 1.3.6.1.4.1.10520.2.1.3.44.88 displaystring read-write
Parameter 84
                               ne843Rpt1D085 1.3.6.1.4.1.10520.2.1.3.44.89 displaystring read-write
Parameter 85
                               ne843Rpt1D086 1.3.6.1.4.1.10520.2.1.3.44.90 displaystring read-write
Parameter 86
                               ne843Rpt1D087 1.3.6.1.4.1.10520.2.1.3.44.91 displaystring read-write
Parameter 87
                               ne843Rpt1D088 1.3.6.1.4.1.10520.2.1.3.44.92 displaystring read-write
Parameter 88
                               ne843Rpt1D089 1.3.6.1.4.1.10520.2.1.3.44.93 displaystring read-write
Parameter 89
                               ne843Rpt1D090 1.3.6.1.4.1.10520.2.1.3.44.94 displaystring read-write
Parameter 90
                               ne843Rpt1D091 1.3.6.1.4.1.10520.2.1.3.44.95 displaystring read-write
Parameter 91
                               ne843Rpt1D092 1.3.6.1.4.1.10520.2.1.3.44.96 displaystring read-write
Parameter 92
                               ne843Rpt1D093 1.3.6.1.4.1.10520.2.1.3.44.97 displaystring read-write
Parameter 93
                               ne843Rpt1D094 1.3.6.1.4.1.10520.2.1.3.44.98 displaystring read-write
Parameter 94
                               ne843Rpt1D095 1.3.6.1.4.1.10520.2.1.3.44.99 displaystring read-write
Parameter 95
                               ne843Rpt1D096 1.3.6.1.4.1.10520.2.1.3.44.100 displaystring read-write
Parameter 96
                               ne843Rpt1D097 1.3.6.1.4.1.10520.2.1.3.44.101 displaystring read-write
Parameter 97
                               ne843Rpt1D098 1.3.6.1.4.1.10520.2.1.3.44.102 displaystring read-write
Parameter 98
                               ne843Rpt1D099 1.3.6.1.4.1.10520.2.1.3.44.103 displaystring read-write
Parameter 99
                               ne843Rpt1D100 1.3.6.1.4.1.10520.2.1.3.44.104 displaystring read-write
Parameter 100
                               ne843Rpt1D101 1.3.6.1.4.1.10520.2.1.3.44.105 displaystring read-write
Parameter 101
                               ne843Rpt1D102 1.3.6.1.4.1.10520.2.1.3.44.106 displaystring read-write
Parameter 102
                               ne843Rpt1D103 1.3.6.1.4.1.10520.2.1.3.44.107 displaystring read-write
Parameter 103
                               ne843Rpt1D104 1.3.6.1.4.1.10520.2.1.3.44.108 displaystring read-write
Parameter 104
                               ne843Rpt1D105 1.3.6.1.4.1.10520.2.1.3.44.109 displaystring read-write
Parameter 105
                               ne843Rpt1D106 1.3.6.1.4.1.10520.2.1.3.44.110 displaystring read-write
Parameter 106
                               ne843Rpt1D107 1.3.6.1.4.1.10520.2.1.3.44.111 displaystring read-write
Parameter 107
                               ne843Rpt1D108 1.3.6.1.4.1.10520.2.1.3.44.112 displaystring read-write
Parameter 108
                               ne843Rpt1D109 1.3.6.1.4.1.10520.2.1.3.44.113 displaystring read-write
Parameter 109
                               ne843Rpt1D110 1.3.6.1.4.1.10520.2.1.3.44.114 displaystring read-write
Parameter 110
                               ne843Rpt1D111 1.3.6.1.4.1.10520.2.1.3.44.115 displaystring read-write
Parameter 111
                               ne843Rpt1D112 1.3.6.1.4.1.10520.2.1.3.44.116 displaystring read-write
Parameter 112
                               ne843Rpt1D113 1.3.6.1.4.1.10520.2.1.3.44.117 displaystring read-write
Parameter 113
                               ne843Rpt1D114 1.3.6.1.4.1.10520.2.1.3.44.118 displaystring read-write
Parameter 114
                               ne843Rpt1D115 1.3.6.1.4.1.10520.2.1.3.44.119 displaystring read-write
Parameter 115
                               ne843Rpt1D116 1.3.6.1.4.1.10520.2.1.3.44.120 displaystring read-write
Parameter 116
                               ne843Rpt1D117 1.3.6.1.4.1.10520.2.1.3.44.121 displaystring read-write
Parameter 117
                               ne843Rpt1D118 1.3.6.1.4.1.10520.2.1.3.44.122 displaystring read-write
Parameter 118
                               ne843Rpt1D119 1.3.6.1.4.1.10520.2.1.3.44.123 displaystring read-write
Parameter 119
                               ne843Rpt1D120 1.3.6.1.4.1.10520.2.1.3.44.124 displaystring read-write
Parameter 120
                               ne843Rpt1D121 1.3.6.1.4.1.10520.2.1.3.44.125 displaystring read-write
Parameter 121
                               ne843Rpt1D122 1.3.6.1.4.1.10520.2.1.3.44.126 displaystring read-write
Parameter 122
                               ne843Rpt1D123 1.3.6.1.4.1.10520.2.1.3.44.127 displaystring read-write
Parameter 123
                               ne843Rpt1D124 1.3.6.1.4.1.10520.2.1.3.44.128 displaystring read-write
Parameter 124
                               ne843Rpt1D125 1.3.6.1.4.1.10520.2.1.3.44.129 displaystring read-write
Parameter 125
                               ne843Rpt1D126 1.3.6.1.4.1.10520.2.1.3.44.130 displaystring read-write
Parameter 126
                               ne843Rpt1D127 1.3.6.1.4.1.10520.2.1.3.44.131 displaystring read-write
Parameter 127
                               ne843Rpt1D128 1.3.6.1.4.1.10520.2.1.3.44.132 displaystring read-write
Parameter 128
                               ne843Rpt1D129 1.3.6.1.4.1.10520.2.1.3.44.133 displaystring read-write
Parameter 129
                               ne843Rpt1D130 1.3.6.1.4.1.10520.2.1.3.44.134 displaystring read-write
Parameter 130
                               ne843Rpt1D131 1.3.6.1.4.1.10520.2.1.3.44.135 displaystring read-write
Parameter 131
                               ne843Rpt1D132 1.3.6.1.4.1.10520.2.1.3.44.136 displaystring read-write
Parameter 132
                               ne843Rpt1D133 1.3.6.1.4.1.10520.2.1.3.44.137 displaystring read-write
Parameter 133
                               ne843Rpt1D134 1.3.6.1.4.1.10520.2.1.3.44.138 displaystring read-write
Parameter 134
                               ne843Rpt1D135 1.3.6.1.4.1.10520.2.1.3.44.139 displaystring read-write
Parameter 135
                               ne843Rpt1D136 1.3.6.1.4.1.10520.2.1.3.44.140 displaystring read-write
Parameter 136
                               ne843Rpt1D137 1.3.6.1.4.1.10520.2.1.3.44.141 displaystring read-write
Parameter 137
                               ne843Rpt1D138 1.3.6.1.4.1.10520.2.1.3.44.142 displaystring read-write
Parameter 138
                               ne843Rpt1D139 1.3.6.1.4.1.10520.2.1.3.44.143 displaystring read-write
Parameter 139
                               ne843Rpt1D140 1.3.6.1.4.1.10520.2.1.3.44.144 displaystring read-write
Parameter 140
                               ne843Rpt1D141 1.3.6.1.4.1.10520.2.1.3.44.145 displaystring read-write
Parameter 141
                               ne843Rpt1D142 1.3.6.1.4.1.10520.2.1.3.44.146 displaystring read-write
Parameter 142
                               ne843Rpt1D143 1.3.6.1.4.1.10520.2.1.3.44.147 displaystring read-write
Parameter 143
                               ne843Rpt1D144 1.3.6.1.4.1.10520.2.1.3.44.148 displaystring read-write
Parameter 144
                               ne843Rpt1D145 1.3.6.1.4.1.10520.2.1.3.44.149 displaystring read-write
Parameter 145
                               ne843Rpt1D146 1.3.6.1.4.1.10520.2.1.3.44.150 displaystring read-write
Parameter 146
                               ne843Rpt1D147 1.3.6.1.4.1.10520.2.1.3.44.151 displaystring read-write
Parameter 147
                               ne843Rpt1D148 1.3.6.1.4.1.10520.2.1.3.44.152 displaystring read-write
Parameter 148
                               ne843Rpt1D149 1.3.6.1.4.1.10520.2.1.3.44.153 displaystring read-write
Parameter 149
                               ne843Rpt1D150 1.3.6.1.4.1.10520.2.1.3.44.154 displaystring read-write
Parameter 150
                         ne843PicTable 1.3.6.1.4.1.10520.2.1.3.45 no-access
Table of all Panel Interface Card data
                               ne843PicEntry 1.3.6.1.4.1.10520.2.1.3.45.1 no-access
Entry of information for one Panel Interface Card
                                   ne843PicEntryIndex 1.3.6.1.4.1.10520.2.1.3.45.1.1 integer read-only
Table Index
                                   ne843PicEntryIde 1.3.6.1.4.1.10520.2.1.3.45.1.2 displaystring read-only
Identifier
                                   ne843PicEntryDes 1.3.6.1.4.1.10520.2.1.3.45.1.3 displaystring read-write
Description
                                   ne843PicEntrySn 1.3.6.1.4.1.10520.2.1.3.45.1.4 displaystring read-only
Serial Number
                                   ne843PicEntryCc 1.3.6.1.4.1.10520.2.1.3.45.1.5 displaystring read-only
Comcode
                                   ne843PicEntrySer 1.3.6.1.4.1.10520.2.1.3.45.1.6 displaystring read-only
Series
                                   ne843PicEntryClei 1.3.6.1.4.1.10520.2.1.3.45.1.7 displaystring read-only
Clei Code
                                   ne843PicEntryCustpn2 1.3.6.1.4.1.10520.2.1.3.45.1.8 displaystring read-only
Customer PIC Part Number
                                   ne843PicEntryAsstag2 1.3.6.1.4.1.10520.2.1.3.45.1.9 displaystring read-only
PIC Asset Tag
                                   ne843PicEntryStt 1.3.6.1.4.1.10520.2.1.3.45.1.10 displaystring read-write
State Values: PRESENT, MISSING, VACANT
                                   ne843PicEntryTyp 1.3.6.1.4.1.10520.2.1.3.45.1.11 displaystring read-write
PIC Type Values: LOAD, BATT
                                   ne843PicEntryNst 1.3.6.1.4.1.10520.2.1.3.45.1.12 integer32 read-write
Number of Shunts
                                   ne843PicEntryNvt 1.3.6.1.4.1.10520.2.1.3.45.1.13 integer32 read-write
Number of Voltages
                                   ne843PicEntryVera 1.3.6.1.4.1.10520.2.1.3.45.1.14 displaystring read-only
Application Software Version
                                   ne843PicEntryPid 1.3.6.1.4.1.10520.2.1.3.45.1.15 displaystring read-only
ID Conflict
                                   ne843PicEntryPcf 1.3.6.1.4.1.10520.2.1.3.45.1.16 displaystring read-only
Communication Failure
                                   ne843PicEntryNumslot 1.3.6.1.4.1.10520.2.1.3.45.1.17 integer32 read-only
Number of Slots
                                   ne843PicEntryCbf 1.3.6.1.4.1.10520.2.1.3.45.1.18 displaystring read-write
CB or Fuse Values: CB, FUSE
                                   ne843PicEntryFajae 1.3.6.1.4.1.10520.2.1.3.45.1.19 integer read-write
External Fuse Enable Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                                   ne843PicEntryFajrly 1.3.6.1.4.1.10520.2.1.3.45.1.20 displaystring read-write
External Fuse Relay Values: None, Enabled
                                   ne843PicEntryOsae 1.3.6.1.4.1.10520.2.1.3.45.1.21 integer read-write
Open String Enable Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                                   ne843PicEntryOsarly 1.3.6.1.4.1.10520.2.1.3.45.1.22 displaystring read-write
Open String Relay Values: None, Enabled
                                   ne843PicEntryTmpe 1.3.6.1.4.1.10520.2.1.3.45.1.23 integer read-write
Temperature Enable Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                                   ne843PicEntryTmprly 1.3.6.1.4.1.10520.2.1.3.45.1.24 displaystring read-write
Temperature Relay Values: None, Enabled
                                   ne843PicEntryVlvs 1.3.6.1.4.1.10520.2.1.3.45.1.25 displaystring read-write
Power Loss Severity Values: CRIT, MAJ, MIN, WRN, RO
                                   ne843PicEntryVlvlat 1.3.6.1.4.1.10520.2.1.3.45.1.26 displaystring read-write
Power Loss Latched
                                   ne843PicEntryVlvae 1.3.6.1.4.1.10520.2.1.3.45.1.27 integer read-write
VA Power Loss Enable Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                                   ne843PicEntryVlvath 1.3.6.1.4.1.10520.2.1.3.45.1.28 integer32 read-write
VB Power Loss Threshold
                                   ne843PicEntryVlvbe 1.3.6.1.4.1.10520.2.1.3.45.1.29 integer read-write
VB Power Loss Enable Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                                   ne843PicEntryVlvbth 1.3.6.1.4.1.10520.2.1.3.45.1.30 integer32 read-write
VB Power Loss Threshold
                                   ne843PicEntryVlvrly 1.3.6.1.4.1.10520.2.1.3.45.1.31 displaystring read-write
Power Loss Relay Values: None, Enabled
                                   ne843PicEntryOvls 1.3.6.1.4.1.10520.2.1.3.45.1.32 displaystring read-write
Overload Severity Values: CRIT, MAJ, MIN, WRN, RO
                                   ne843PicEntryOlvlat 1.3.6.1.4.1.10520.2.1.3.45.1.33 displaystring read-write
Overload Latched
                                   ne843PicEntryOvlae 1.3.6.1.4.1.10520.2.1.3.45.1.34 integer read-write
IA Overload Enabled Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                                   ne843PicEntryOvlath 1.3.6.1.4.1.10520.2.1.3.45.1.35 integer32 read-write
IA Overload Threshold
                                   ne843PicEntryOvlbe 1.3.6.1.4.1.10520.2.1.3.45.1.36 integer read-write
IB Overload Enabled Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                                   ne843PicEntryOvlbth 1.3.6.1.4.1.10520.2.1.3.45.1.37 integer32 read-write
IB Overload Threshold
                                   ne843PicEntryOvlrly 1.3.6.1.4.1.10520.2.1.3.45.1.38 displaystring read-write
Overload Relay Values: None, Enabled
                                   ne843PicEntryEpoe 1.3.6.1.4.1.10520.2.1.3.45.1.39 integer read-write
Emergency Power Off Enabled Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                                   ne843PicEntryEporly 1.3.6.1.4.1.10520.2.1.3.45.1.40 displaystring read-write
Emergency Power Off Relay Values: None, Enabled
                                   ne843PicEntryPcauxe 1.3.6.1.4.1.10520.2.1.3.45.1.41 integer read-write
PIC Auxiliary Enabled Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                                   ne843PicEntryPcauxr 1.3.6.1.4.1.10520.2.1.3.45.1.42 displaystring read-write
PIC Auxiliary Relay Values: None, Enabled
                                   ne843PicEntrySlote 1.3.6.1.4.1.10520.2.1.3.45.1.43 integer read-write
Slot Enabled Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                                   ne843PicEntrySlotrly 1.3.6.1.4.1.10520.2.1.3.45.1.44 displaystring read-write
Slot Relay Values: None, Enabled
                                   ne843PicEntryDpmode 1.3.6.1.4.1.10520.2.1.3.45.1.45 displaystring read-write
Display Mode Values: SCAN, STATIC
                                   ne843PicEntryPnldes 1.3.6.1.4.1.10520.2.1.3.45.1.46 displaystring read-write
Panel Description
                                   ne843PicEntryMdl 1.3.6.1.4.1.10520.2.1.3.45.1.47 displaystring read-write
Panel Model
                                   ne843PicEntryPnlsn 1.3.6.1.4.1.10520.2.1.3.45.1.48 displaystring read-write
Panel Serial Number
                                   ne843PicEntryPnlcc 1.3.6.1.4.1.10520.2.1.3.45.1.49 displaystring read-write
Panel Comcode
                                   ne843PicEntryPnlser 1.3.6.1.4.1.10520.2.1.3.45.1.50 displaystring read-write
Panel Series
                                   ne843PicEntryPnlclei 1.3.6.1.4.1.10520.2.1.3.45.1.51 displaystring read-write
Panel Clei Code
                                   ne843PicEntryCustpn1 1.3.6.1.4.1.10520.2.1.3.45.1.52 displaystring read-write
Panel Customer Part Number
                                   ne843PicEntryAsstag1 1.3.6.1.4.1.10520.2.1.3.45.1.53 displaystring read-write
Panel Customer Asset Tag
                                   ne843PicEntryRtng 1.3.6.1.4.1.10520.2.1.3.45.1.54 displaystring read-write
Panel Rating
                                   ne843PicEntryPnlsize 1.3.6.1.4.1.10520.2.1.3.45.1.55 displaystring read-write
Panel Size
                         ne843PcmTable 1.3.6.1.4.1.10520.2.1.3.46 no-access
Table of all PIC Current Monitor data
                               ne843PcmEntry 1.3.6.1.4.1.10520.2.1.3.46.1 no-access
Entry of information for one PIC Current Monitor
                                   ne843PcmEntryIndex 1.3.6.1.4.1.10520.2.1.3.46.1.1 integer read-only
Table Index
                                   ne843PcmEntryIde 1.3.6.1.4.1.10520.2.1.3.46.1.2 displaystring read-only
Identifier
                                   ne843PcmEntryDes 1.3.6.1.4.1.10520.2.1.3.46.1.3 displaystring read-write
Description
                                   ne843PcmEntryVal 1.3.6.1.4.1.10520.2.1.3.46.1.4 displaystring read-only
Value
                                   ne843PcmEntrySht 1.3.6.1.4.1.10520.2.1.3.46.1.5 displaystring read-write
Shunt Type Values: LOAD, BATTERY, NONE
                                   ne843PcmEntrySha 1.3.6.1.4.1.10520.2.1.3.46.1.6 integer32 read-write
Shunt Current
                                   ne843PcmEntryShv 1.3.6.1.4.1.10520.2.1.3.46.1.7 integer32 read-write
Shunt Voltage
                         ne843PvmTable 1.3.6.1.4.1.10520.2.1.3.47 no-access
Table of all PIC Voltage Monitor data
                               ne843PvmEntry 1.3.6.1.4.1.10520.2.1.3.47.1 no-access
Entry of information for one PIC Voltage Monitor
                                   ne843PvmEntryIndex 1.3.6.1.4.1.10520.2.1.3.47.1.1 integer read-only
Table Index
                                   ne843PvmEntryIde 1.3.6.1.4.1.10520.2.1.3.47.1.2 displaystring read-only
Identifier
                                   ne843PvmEntryDes 1.3.6.1.4.1.10520.2.1.3.47.1.3 displaystring read-write
Description
                                   ne843PvmEntryVal 1.3.6.1.4.1.10520.2.1.3.47.1.4 integer32 read-only
Value
                         ne843PtmTable 1.3.6.1.4.1.10520.2.1.3.48 no-access
Table of all PIC Temperature Monitor data
                               ne843PtmEntry 1.3.6.1.4.1.10520.2.1.3.48.1 no-access
Entry of information for one PIC Temperature Monitor
                                   ne843PtmEntryIndex 1.3.6.1.4.1.10520.2.1.3.48.1.1 integer read-only
Table Index
                                   ne843PtmEntryIde 1.3.6.1.4.1.10520.2.1.3.48.1.2 displaystring read-only
Identifier
                                   ne843PtmEntryDes 1.3.6.1.4.1.10520.2.1.3.48.1.3 displaystring read-write
Description
                                   ne843PtmEntryBamt 1.3.6.1.4.1.10520.2.1.3.48.1.4 integer32 read-only
Board Ambient Temperature
                                   ne843PtmEntryNat 1.3.6.1.4.1.10520.2.1.3.48.1.5 integer32 read-only
Number of Ambient Temperature Probes
                                   ne843PtmEntryHamt 1.3.6.1.4.1.10520.2.1.3.48.1.6 integer32 read-only
Hi Ambient Temperature
                                   ne843PtmEntryLamt 1.3.6.1.4.1.10520.2.1.3.48.1.7 integer32 read-only
Low Ambient Temperature
                                   ne843PtmEntryNtm 1.3.6.1.4.1.10520.2.1.3.48.1.8 integer32 read-only
Number of Battery Temperature Probes
                                   ne843PtmEntryHbt 1.3.6.1.4.1.10520.2.1.3.48.1.9 integer32 read-only
Hi Battery Temperature
                                   ne843PtmEntryLbt 1.3.6.1.4.1.10520.2.1.3.48.1.10 integer32 read-only
Low Battery Temperature
                                   ne843PtmEntryNbut 1.3.6.1.4.1.10520.2.1.3.48.1.11 integer32 read-only
Number of Bus Temperature Probes
                                   ne843PtmEntryHbut 1.3.6.1.4.1.10520.2.1.3.48.1.12 integer32 read-only
Hi Bus Temperature
                                   ne843PtmEntryLbut 1.3.6.1.4.1.10520.2.1.3.48.1.13 integer32 read-only
Low Bust Temperature
                         ne843PcsTable 1.3.6.1.4.1.10520.2.1.3.49 no-access
Table of all PIC Slot data
                               ne843PcsEntry 1.3.6.1.4.1.10520.2.1.3.49.1 no-access
Entry of information for one PIC Slot
                                   ne843PcsEntryIndex 1.3.6.1.4.1.10520.2.1.3.49.1.1 integer read-only
Table Index
                                   ne843PcsEntryIde 1.3.6.1.4.1.10520.2.1.3.49.1.2 displaystring read-only
Identifier
                                   ne843PcsEntryDes 1.3.6.1.4.1.10520.2.1.3.49.1.3 displaystring read-write
Description
                                   ne843PcsEntryStt 1.3.6.1.4.1.10520.2.1.3.49.1.4 displaystring read-only
Status
                                   ne843PcsEntryTyp 1.3.6.1.4.1.10520.2.1.3.49.1.5 displaystring read-write
Type Values: Load, Batt, picType
                                   ne843PcsEntryPole 1.3.6.1.4.1.10520.2.1.3.49.1.6 integer32 read-write
Number of Poles
                                   ne843PcsEntryPolp 1.3.6.1.4.1.10520.2.1.3.49.1.7 integer32 read-write
Slot Pole Position
                                   ne843PcsEntryPopn 1.3.6.1.4.1.10520.2.1.3.49.1.8 displaystring read-write
Slot Pole Open/Closed Values: Open, Closed
                                   ne843PcsEntryTrp 1.3.6.1.4.1.10520.2.1.3.49.1.9 integer read-write
Slot Tripped Values: off(0), on(1) Enumeration: 'on': 1, 'off': 0.
                                   ne843PcsEntryBad 1.3.6.1.4.1.10520.2.1.3.49.1.10 integer read-write
Slot Bad Values: off(0), on(1) Enumeration: 'on': 1, 'off': 0.
                                   ne843PcsEntryCbf 1.3.6.1.4.1.10520.2.1.3.49.1.11 displaystring read-write
Slot CB or Fuse Values: CB, Fuse
                                   ne843PcsEntrySlv 1.3.6.1.4.1.10520.2.1.3.49.1.12 integer read-write
Slot Slave Values: off(0), on(1) Enumeration: 'on': 1, 'off': 0.
                                   ne843PcsEntryRtng 1.3.6.1.4.1.10520.2.1.3.49.1.13 integer32 read-write
Slot Rtng
                         ne843DbyTable 1.3.6.1.4.1.10520.2.1.3.50 no-access
Table of all Distribution Bay data
                               ne843DbyEntry 1.3.6.1.4.1.10520.2.1.3.50.1 no-access
Entry of information for one Distribution Bay
                                   ne843DbyEntryIndex 1.3.6.1.4.1.10520.2.1.3.50.1.1 integer read-only
Table Index
                                   ne843DbyEntryIde 1.3.6.1.4.1.10520.2.1.3.50.1.2 displaystring read-only
Identifier
                                   ne843DbyEntryDes 1.3.6.1.4.1.10520.2.1.3.50.1.3 displaystring read-write
Description
                                   ne843DbyEntrySn 1.3.6.1.4.1.10520.2.1.3.50.1.4 displaystring read-only
Serial Number
                                   ne843DbyEntryStt 1.3.6.1.4.1.10520.2.1.3.50.1.5 displaystring read-only
State
                                   ne843DbyEntrySha 1.3.6.1.4.1.10520.2.1.3.50.1.6 integer32 read-write
Shunt Rating (Amps)
                                   ne843DbyEntryNpl 1.3.6.1.4.1.10520.2.1.3.50.1.7 integer32 read-write
Number of Panels
                                   ne843DbyEntryPmt 1.3.6.1.4.1.10520.2.1.3.50.1.8 displaystring read-write
Measurement Type
                                   ne843DbyEntryIds 1.3.6.1.4.1.10520.2.1.3.50.1.9 displaystring read-write
Identification Style
                                   ne843DbyEntryBze 1.3.6.1.4.1.10520.2.1.3.50.1.10 integer read-write
Buzzer Enable Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                                   ne843DbyEntryOle 1.3.6.1.4.1.10520.2.1.3.50.1.11 integer read-write
Overload Latch Enable Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                                   ne843DbyEntryOri 1.3.6.1.4.1.10520.2.1.3.50.1.12 displaystring read-write
Panel Orientation
                                   ne843DbyEntryCmb 1.3.6.1.4.1.10520.2.1.3.50.1.13 integer read-write
Combine Panels Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                                   ne843DbyEntrySmw 1.3.6.1.4.1.10520.2.1.3.50.1.14 displaystring read-only
Shunt Miswired
                                   ne843DbyEntryCca 1.3.6.1.4.1.10520.2.1.3.50.1.15 displaystring read-only
Circuit Assignment
                         ne843DpnTable 1.3.6.1.4.1.10520.2.1.3.51 no-access
Table of all Distribution Panel data
                               ne843DpnEntry 1.3.6.1.4.1.10520.2.1.3.51.1 no-access
Entry of information for one Distribution Panel
                                   ne843DpnEntryIndex 1.3.6.1.4.1.10520.2.1.3.51.1.1 integer read-only
Table Index
                                   ne843DpnEntryIde 1.3.6.1.4.1.10520.2.1.3.51.1.2 displaystring read-only
Identifier
                                   ne843DpnEntryDes 1.3.6.1.4.1.10520.2.1.3.51.1.3 displaystring read-write
Description
                                   ne843DpnEntryAdc 1.3.6.1.4.1.10520.2.1.3.51.1.4 integer32 read-only
Current (Amps)
                                   ne843DpnEntryVdc 1.3.6.1.4.1.10520.2.1.3.51.1.5 integer32 read-only
Voltage (mV)
                                   ne843DpnEntryStt 1.3.6.1.4.1.10520.2.1.3.51.1.6 displaystring read-only
State
                                   ne843DpnEntryPid 1.3.6.1.4.1.10520.2.1.3.51.1.7 integer32 read-only
Panel ID
                                   ne843DpnEntryEna 1.3.6.1.4.1.10520.2.1.3.51.1.8 integer read-write
Enable Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                                   ne843DpnEntryOld 1.3.6.1.4.1.10520.2.1.3.51.1.9 integer32 read-write
Overload Delay (Seconds)
                                   ne843DpnEntryOlt 1.3.6.1.4.1.10520.2.1.3.51.1.10 integer32 read-write
Overload Threshold (amps)
                                   ne843DpnEntryOlr 1.3.6.1.4.1.10520.2.1.3.51.1.11 integer read-write
Redundant Overload Values: disable(0), enable(1) Enumeration: 'enable': 1, 'disable': 0.
                                   ne843DpnEntryPlt 1.3.6.1.4.1.10520.2.1.3.51.1.12 integer32 read-write
Power Loss Threshold (mV)
                                   ne843DpnEntryCct 1.3.6.1.4.1.10520.2.1.3.51.1.13 integer32 read-write
Input Circuit
                                   ne843DpnEntryVlv 1.3.6.1.4.1.10520.2.1.3.51.1.14 displaystring read-only
Power Loss
                                   ne843DpnEntryOvl 1.3.6.1.4.1.10520.2.1.3.51.1.15 displaystring read-only
Overload
                                   ne843DpnEntryFaja 1.3.6.1.4.1.10520.2.1.3.51.1.16 displaystring read-only
Distribution Fuse A
                                   ne843DpnEntryFajb 1.3.6.1.4.1.10520.2.1.3.51.1.17 displaystring read-only
Distribution Fuse B