NBS-SIGCOND-MIB: View SNMP OID List / Download MIB

VENDOR: NBASE SWITCH COMMUNICATION


 Home MIB: NBS-SIGCOND-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 nbsSigCondMib 1.3.6.1.4.1.629.227
Signal Conditioning mib
         nbsSigCondVoaPortGrp 1.3.6.1.4.1.629.227.1
Variable Optical Attenuation at the port level.
             nbsSigCondVoaPortTableSize 1.3.6.1.4.1.629.227.1.1 unsigned32 read-only
The number of ports supporting variable optical attenuation at the port level.
             nbsSigCondVoaPortTable 1.3.6.1.4.1.629.227.1.2 no-access
List of ports supporting variable optical attenuation at the port level.
                 nbsSigCondVoaPortEntry 1.3.6.1.4.1.629.227.1.2.1 no-access
                     nbsSigCondVoaPortIfIndex 1.3.6.1.4.1.629.227.1.2.1.1 interfaceindex no-access
The Mib2 ifIndex of the attenuable port.
                     nbsSigCondVoaPortRxAttenuAdmin 1.3.6.1.4.1.629.227.1.2.1.2 integer read-write
Persistent and immediately updated. User-requested attenuation to be applied to received signal, expressed in millidecibels (mdB). Not supported value: -200000
                     nbsSigCondVoaPortRxAttenuOper 1.3.6.1.4.1.629.227.1.2.1.3 integer read-only
Attenuation actually being applied to received signal, in millidecibels (mdB). Not supported value: -200000
                     nbsSigCondVoaPortTxAttenuAdmin 1.3.6.1.4.1.629.227.1.2.1.4 integer read-write
Persistent and immediately updated. User-requested attenuation to be applied before transmitting signal, expressed in millidecibels (mdB). Not supported value: -200000
                     nbsSigCondVoaPortTxAttenuOper 1.3.6.1.4.1.629.227.1.2.1.5 integer read-only
Attenuation actually being applied before transmitting signal, in millidecibels (mdB). Not supported value: -200000
         nbsSigCondVoaFlowGrp 1.3.6.1.4.1.629.227.2
Variable Optical Attenuation at the port.frequency.direction level.
             nbsSigCondVoaFlowTableSize 1.3.6.1.4.1.629.227.2.1 unsigned32 read-only
The number of attenuable flows in this system.
             nbsSigCondVoaFlowTable 1.3.6.1.4.1.629.227.2.2 no-access
Table of attenuable flows.
                 nbsSigCondVoaFlowEntry 1.3.6.1.4.1.629.227.2.2.1 no-access
Reports status of monitored frequencies.
                     nbsSigCondVoaFlowIfIndex 1.3.6.1.4.1.629.227.2.2.1.1 interfaceindex no-access
The Mib2 ifIndex of the optical spectrum analyzer port
                     nbsSigCondVoaFlowWavelength 1.3.6.1.4.1.629.227.2.2.1.2 integer no-access
The nominal wavelength, in picometers, of this channel.
                     nbsSigCondVoaFlowDirection 1.3.6.1.4.1.629.227.2.2.1.3 integer no-access
Third index of table. The value rx(1) indicates the received signal, and tx(2) indicates the transmitted signal. Enumeration: 'rx': 1, 'tx': 2.
                     nbsSigCondVoaFlowAttenuAdmin 1.3.6.1.4.1.629.227.2.2.1.4 integer read-write
Persistent and immediately updated. User-requested attenuation to be applied to signal, expressed in millidecibels (mdB).
                     nbsSigCondVoaFlowAttenuOper 1.3.6.1.4.1.629.227.2.2.1.5 integer read-only
Attenuation actually being applied to signal, in millidecibels (mdB).
         nbsSigCondRamanGrp 1.3.6.1.4.1.629.227.3
Raman amplifier information for the port.
             nbsSigCondRamanTableSize 1.3.6.1.4.1.629.227.3.1 unsigned32 read-only
The number of raman ports in this system.
             nbsSigCondRamanTable 1.3.6.1.4.1.629.227.3.2 no-access
Table of Raman readings.
                 nbsSigCondRamanEntry 1.3.6.1.4.1.629.227.3.2.1 no-access
Raman readings on an individual port.
                     nbsSigCondRamanIfIndex 1.3.6.1.4.1.629.227.3.2.1.1 interfaceindex no-access
The Mib2 ifIndex of the Raman port
                     nbsSigCondRamanPumpPwrAdmin 1.3.6.1.4.1.629.227.3.2.1.2 integer read-write
Persistent and immediately updated. User-requested pump power, in microwatts (uW). User interfaces should show this in millWatts (mW). Not supported value: -1
                     nbsSigCondRamanPumpPwrOper 1.3.6.1.4.1.629.227.3.2.1.3 integer read-only
Agent reported pump power, in microwatts (uW). User interfaces should show this in millWatts (mW). Not supported value: -1
         nbsSigCondPortGrp 1.3.6.1.4.1.629.227.100
Power readings from the port.
                 nbsSigCondPortTableSize 1.3.6.1.4.1.629.227.100.1 unsigned32 read-only
The number of entries in nbsSigCondPortTable.
                 nbsSigCondPortTable 1.3.6.1.4.1.629.227.100.2 no-access
Table of VOA and VGA ports.
                     nbsSigCondPortEntry 1.3.6.1.4.1.629.227.100.2.1 no-access
                         nbsSigCondPortIfIndex 1.3.6.1.4.1.629.227.100.2.1.1 interfaceindex no-access
The Mib2 ifIndex of the Port port
                         nbsSigCondPortRxPower 1.3.6.1.4.1.629.227.100.2.1.2 integer read-only
Measured receiver power, in millidecibels (mdBm). User interfaces should show this in decibels (dBm). Not supported value: -100000
                         nbsSigCondPortTxPower 1.3.6.1.4.1.629.227.100.2.1.3 integer read-only
Measured transmitter power, in millidecibels (mdBm). User interfaces should show this in decibels (dBm). Not supported value: -100000
                         nbsSigCondPortReflection 1.3.6.1.4.1.629.227.100.2.1.4 integer read-only
Measured back reflection power, in millidecibels (mdBm). User interfaces should show this in decibels (dBm). Not supported value: -100000
         nbsSigCondTraps 1.3.6.1.4.1.629.227.200
SNMP Traps or Notifications
                 nbsSigCondTrap0 1.3.6.1.4.1.629.227.200.0
SNMP Traps or Notifications