Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 nbsOdsysMib 1.3.6.1.4.1.629.228
For managing Opti-Driver systems.
         nbsOdsysChasGrp 1.3.6.1.4.1.629.228.2
Chassis component overview
             nbsOdsysChasTable 1.3.6.1.4.1.629.228.2.1 no-access
                 nbsOdsysChasEntry 1.3.6.1.4.1.629.228.2.1.1 no-access
Information about a particular OptiDriver chassis.
                     nbsOdsysChasIndex 1.3.6.1.4.1.629.228.2.1.1.1 integer read-only
The nbsCmmcChassisIndex of this chassis
                     nbsOdsysChasCcMaxCount 1.3.6.1.4.1.629.228.2.1.1.10 integer read-only
The maximum number of control cards that can be installed in this chassis
                     nbsOdsysChasPsMaxCount 1.3.6.1.4.1.629.228.2.1.1.20 integer read-only
The number of power supply bays/slots in this chassis
                     nbsOdsysChasFtMaxCount 1.3.6.1.4.1.629.228.2.1.1.30 integer read-only
The number of fan tray bays/slots in this chassis
         nbsOdsysCcGrp 1.3.6.1.4.1.629.228.3
Chassis control card information
             nbsOdsysCcTable 1.3.6.1.4.1.629.228.3.1 no-access
Information about OptiDriver chassis control/fpga cards
                 nbsOdsysCcEntry 1.3.6.1.4.1.629.228.3.1.1 no-access
Status information for a particular control card slot/bay. When a control card is present, it will also have entries in nbsPartHardTable, nbsPartFirmTable, and nbsPartProgTable. The events nbsOdsysTrapCcFailed, nbsOdsysTrapCcRestored, nbsOdsysTrapCcRemoved and nbsOdsysTrapCcInserted indicate changes in nbsOdsysCcOperationalStatus.
                     nbsOdsysCcChasIndex 1.3.6.1.4.1.629.228.3.1.1.1 integer read-only
The nbsCmmcChassisIndex of this control card's chassis
                     nbsOdsysCcBayIndex 1.3.6.1.4.1.629.228.3.1.1.2 integer read-only
The control card slot/bay #
                     nbsOdsysCcChIfIndex 1.3.6.1.4.1.629.228.3.1.1.10 interfaceindex read-only
The nbsPartHardIfIndex of this Cc daughtercard's chassis
                     nbsOdsysCcPartIndex 1.3.6.1.4.1.629.228.3.1.1.11 nbstcpartindex read-only
The nbsPartHardPartIndex of this Cc daughtercard
                     nbsOdsysCcThermActual 1.3.6.1.4.1.629.228.3.1.1.30 nbstctemperature read-only
Indicates the current temperature reading, in degrees celsius
                     nbsOdsysCcThermLevel 1.3.6.1.4.1.629.228.3.1.1.40 nbstcstatuslevel read-only
Indicates level of current temperature reading with respect to the CcTherm threshold objects below
                     nbsOdsysCcThermThreshLoErr 1.3.6.1.4.1.629.228.3.1.1.41 nbstctemperature read-only
Indicates the minimum functional operating temperature, in degrees celsius
                     nbsOdsysCcThermThreshLoWarn 1.3.6.1.4.1.629.228.3.1.1.42 nbstctemperature read-only
Indicates the minimum safe operating temperature, in degrees celsius
                     nbsOdsysCcThermThreshHiWarn 1.3.6.1.4.1.629.228.3.1.1.43 nbstctemperature read-only
Indicates the maximum safe operating temperature, in degrees celsius
                     nbsOdsysCcThermThreshHiErr 1.3.6.1.4.1.629.228.3.1.1.44 nbstctemperature read-only
Indicates the maximum functional operating temperature, in degrees celsius
                     nbsOdsysCcOperationalStatus 1.3.6.1.4.1.629.228.3.1.1.50 nbstcstatussimple read-only
Operational status of this daughtercard
         nbsOdsysFtGrp 1.3.6.1.4.1.629.228.4
Chassis cooling system
             nbsOdsysFtTable 1.3.6.1.4.1.629.228.4.1 no-access
                 nbsOdsysFtEntry 1.3.6.1.4.1.629.228.4.1.1 no-access
A particular chassis cooling assembly slot/bay. Each installed fan tray also has entries in nbsPartHardTable. The events nbsCmmcTrapFanFailure, nbsCmmcTrapFanRestored, nbsCmmcTrapFanRemoved and nbsCmmcTrapFanInserted indicate changes in nbsOdsysFtOperationalStatus.
                     nbsOdsysFtChasIndex 1.3.6.1.4.1.629.228.4.1.1.1 integer read-only
nbsCmmcChassisIndex of this fan tray's chassis
                     nbsOdsysFtBayIndex 1.3.6.1.4.1.629.228.4.1.1.2 integer read-only
Fan tray bay/slot number, unique within this chassis
                     nbsOdsysFtOperationalStatus 1.3.6.1.4.1.629.228.4.1.1.3 nbstcstatussimple read-only
The value notSupported(1) indicates the fan tray is absent.
                     nbsOdsysFtChIfIndex 1.3.6.1.4.1.629.228.4.1.1.10 interfaceindex read-only
The nbsPartHardIfIndex of this fan tray's chassis
                     nbsOdsysFtPartIndex 1.3.6.1.4.1.629.228.4.1.1.11 nbstcpartindex read-only
The nbsPartHardPartIndex of this fan tray
                     nbsOdsysFtFanCount 1.3.6.1.4.1.629.228.4.1.1.20 integer read-only
The number of fans in this tray
                     nbsOdsysFtThermActual 1.3.6.1.4.1.629.228.4.1.1.30 nbstctemperature read-only
Indicates the current temperature reading, in degrees celsius
                     nbsOdsysFtThermLevel 1.3.6.1.4.1.629.228.4.1.1.40 nbstcstatuslevel read-only
Indicates level of current temperature reading with respect to the FtTherm threshold objects below
                     nbsOdsysFtThermThreshLoErr 1.3.6.1.4.1.629.228.4.1.1.41 nbstctemperature read-only
Indicates the minimum functional operating temperature, in degrees celsius
                     nbsOdsysFtThermThreshLoWarn 1.3.6.1.4.1.629.228.4.1.1.42 nbstctemperature read-only
Indicates the minimum safe operating temperature, in degrees celsius
                     nbsOdsysFtThermThreshHiWarn 1.3.6.1.4.1.629.228.4.1.1.43 nbstctemperature read-only
Indicates the maximum safe operating temperature, in degrees celsius
                     nbsOdsysFtThermThreshHiErr 1.3.6.1.4.1.629.228.4.1.1.44 nbstctemperature read-only
Indicates the maximum functional operating temperature, in degrees celsius
         nbsOdsysPsGrp 1.3.6.1.4.1.629.228.5
Chassis power supplies
             nbsOdsysPsTable 1.3.6.1.4.1.629.228.5.2 no-access
Information about OptiDriver chassis' power supplies
                 nbsOdsysPsEntry 1.3.6.1.4.1.629.228.5.2.1 no-access
A particular power supply slot/bay. Each installed power supply also has entries in nbsPartHardTable. The events nbsCmmcTrapPowerSupplyFailure, nbsCmmcTrapPowerSupplyRestored, nbsCmmcTrapPowerSupplyRemoved, and nbsCmmcTrapPowerSupplyInserted indicate changes in nbsOdsysFtOperationalStatus.
                     nbsOdsysPsChasIndex 1.3.6.1.4.1.629.228.5.2.1.1 integer read-only
The nbsCmmcChassisIndex of this power supply's chassis
                     nbsOdsysPsBayIndex 1.3.6.1.4.1.629.228.5.2.1.2 integer read-only
Number of this power supply slot/bay
                     nbsOdsysPsOperationalStatus 1.3.6.1.4.1.629.228.5.2.1.3 nbstcstatussimple read-only
The value notSupported(1) indicates power supply is absent.
                     nbsOdsysPsChIfIndex 1.3.6.1.4.1.629.228.5.2.1.10 interfaceindex read-only
The nbsPartHardIfIndex of this power supply's chassis
                     nbsOdsysPsPartIndex 1.3.6.1.4.1.629.228.5.2.1.11 nbstcpartindex read-only
The nbsPartHardPartIndex of this power supply
                     nbsOdsysPsFanCount 1.3.6.1.4.1.629.228.5.2.1.30 integer read-only
Indicates how many internal fans this power supply has.
                     nbsOdsysPsThermActual 1.3.6.1.4.1.629.228.5.2.1.40 nbstctemperature read-only
Indicates the current temperature reading, in degrees celsius
                     nbsOdsysPsThermLevel 1.3.6.1.4.1.629.228.5.2.1.41 nbstcstatuslevel read-only
Indicates level of current temperature reading with respect to the PsTherm threshold objects below
                     nbsOdsysPsThermThreshLoErr 1.3.6.1.4.1.629.228.5.2.1.42 nbstctemperature read-only
Indicates the minimum functional operating temperature, in degrees celsius
                     nbsOdsysPsThermThreshLoWarn 1.3.6.1.4.1.629.228.5.2.1.43 nbstctemperature read-only
Indicates the minimum safe operating temperature, in degrees celsius
                     nbsOdsysPsThermThreshHiWarn 1.3.6.1.4.1.629.228.5.2.1.44 nbstctemperature read-only
Indicates the maximum safe operating temperature, in degrees celsius
                     nbsOdsysPsThermThreshHiErr 1.3.6.1.4.1.629.228.5.2.1.45 nbstctemperature read-only
Indicates the maximum functional operating temperature, in degrees celsius
                     nbsOdsysPsVInActual 1.3.6.1.4.1.629.228.5.2.1.50 nbstcmillivolt read-only
Indicates the input voltage reading, in millivolts
                     nbsOdsysPsVInLevel 1.3.6.1.4.1.629.228.5.2.1.51 nbstcstatuslevel read-only
Indicates level of input voltage reading with respect to the PsVIn threshold objects below
                     nbsOdsysPsVInThreshLoErr 1.3.6.1.4.1.629.228.5.2.1.52 nbstcmillivolt read-only
Indicates the minimum functional input voltage, in millivolts
                     nbsOdsysPsVInThreshLoWarn 1.3.6.1.4.1.629.228.5.2.1.53 nbstcmillivolt read-only
Indicates the minimum safe input voltage, in millivolts
                     nbsOdsysPsVInThreshHiWarn 1.3.6.1.4.1.629.228.5.2.1.54 nbstcmillivolt read-only
Indicates the maximum safe input voltage, in millivolts
                     nbsOdsysPsVInThreshHiErr 1.3.6.1.4.1.629.228.5.2.1.55 nbstcmillivolt read-only
Indicates the maximum functional input voltage, in millivolts
                     nbsOdsysPsVOutActual 1.3.6.1.4.1.629.228.5.2.1.60 nbstcmillivolt read-only
Indicates the output voltage reading, in millivolts
                     nbsOdsysPsVOutLevel 1.3.6.1.4.1.629.228.5.2.1.61 nbstcstatuslevel read-only
Indicates level of output voltage reading with respect to the PsVOut threshold objects below
                     nbsOdsysPsVOutThreshLoErr 1.3.6.1.4.1.629.228.5.2.1.62 nbstcmillivolt read-only
Indicates the minimum functional output voltage, in millivolts
                     nbsOdsysPsVOutThreshLoWarn 1.3.6.1.4.1.629.228.5.2.1.63 nbstcmillivolt read-only
Indicates the minimum safe output voltage, in millivolts
                     nbsOdsysPsVOutThreshHiWarn 1.3.6.1.4.1.629.228.5.2.1.64 nbstcmillivolt read-only
Indicates the maximum safe output voltage, in millivolts
                     nbsOdsysPsVOutThreshHiErr 1.3.6.1.4.1.629.228.5.2.1.65 nbstcmillivolt read-only
Indicates the maximum functional output voltage, in millivolts
                     nbsOdsysPsIInActual 1.3.6.1.4.1.629.228.5.2.1.70 nbstcmilliamp read-only
Indicates the input current reading, in milliamps
                     nbsOdsysPsIInLevel 1.3.6.1.4.1.629.228.5.2.1.71 nbstcstatuslevel read-only
Indicates level of input current reading with respect to the PsIIn threshold objects below
                     nbsOdsysPsIInThreshLoErr 1.3.6.1.4.1.629.228.5.2.1.72 nbstcmilliamp read-only
Indicates the minimum functional input current, in milliamps
                     nbsOdsysPsIInThreshLoWarn 1.3.6.1.4.1.629.228.5.2.1.73 nbstcmilliamp read-only
Indicates the minimum safe input current, in milliamps
                     nbsOdsysPsIInThreshHiWarn 1.3.6.1.4.1.629.228.5.2.1.74 nbstcmilliamp read-only
Indicates the maximum safe input current, in milliamps
                     nbsOdsysPsIInThreshHiErr 1.3.6.1.4.1.629.228.5.2.1.75 nbstcmilliamp read-only
Indicates the maximum functional input current, in milliamps
                     nbsOdsysPsIOutActual 1.3.6.1.4.1.629.228.5.2.1.80 nbstcmilliamp read-only
Indicates the output current, in milliamps
                     nbsOdsysPsIOutLevel 1.3.6.1.4.1.629.228.5.2.1.81 nbstcstatuslevel read-only
Indicates level of output current reading with respect to the PsIOut threshold objects below
                     nbsOdsysPsIOutThreshLoErr 1.3.6.1.4.1.629.228.5.2.1.82 nbstcmilliamp read-only
Indicates the minimum functional output current, in milliamps
                     nbsOdsysPsIOutThreshLoWarn 1.3.6.1.4.1.629.228.5.2.1.83 nbstcmilliamp read-only
Indicates the minimum safe output current, in milliamps
                     nbsOdsysPsIOutThreshHiWarn 1.3.6.1.4.1.629.228.5.2.1.84 nbstcmilliamp read-only
Indicates the maximum safe output current, in milliamps
                     nbsOdsysPsIOutThreshHiErr 1.3.6.1.4.1.629.228.5.2.1.85 nbstcmilliamp read-only
Indicates the maximum functional output current, in milliamps
         nbsOdsysEventsGrp 1.3.6.1.4.1.629.228.100
                 nbsOdsysEvents 1.3.6.1.4.1.629.228.100.0
Event NOTIFICATIONS
                     nbsOdsysTrapCcThermLevelBad 1.3.6.1.4.1.629.228.100.0.30
Sent when nbsOdsysCcThermLevel changes to anything but statusGood (4)
                     nbsOdsysTrapCcThermLevelOk 1.3.6.1.4.1.629.228.100.0.31
Sent when nbsOdsysCcThermLevel changes to statusGood (4)
                     nbsOdsysTrapFtThermLevelBad 1.3.6.1.4.1.629.228.100.0.40
Sent when fan tray's nbsOdsysFtThermLevel changes to anything but statusGood (4)
                     nbsOdsysTrapFtThermLevelOk 1.3.6.1.4.1.629.228.100.0.41
Sent when fan tray's nbsOdsysFtThermLevel changes to statusGood (4)
                     nbsOdsysTrapPsThermLevelBad 1.3.6.1.4.1.629.228.100.0.50
Sent when power supply's nbsOdsysPsThermLevel changes to anything but statusGood (4)
                     nbsOdsysTrapPsThermLevelOk 1.3.6.1.4.1.629.228.100.0.51
Sent when power supply's nbsOdsysPsThermLevel changes to statusGood (4)
                     nbsOdsysTrapPsVInLevelBad 1.3.6.1.4.1.629.228.100.0.60
Sent when power supply's nbsOdsysPsVInLevel changes to anything but statusGood (4)
                     nbsOdsysTrapPsVInLevelOk 1.3.6.1.4.1.629.228.100.0.61
Sent when power supply's nbsOdsysPsVInLevel changes to statusGood (4)
                     nbsOdsysTrapPsVOutLevelBad 1.3.6.1.4.1.629.228.100.0.70
Sent when power supply's nbsOdsysPsVOutLevel changes to anything but statusGood (4)
                     nbsOdsysTrapPsVOutLevelOk 1.3.6.1.4.1.629.228.100.0.71
Sent when power supply's nbsOdsysPsVOutLevel changes to statusGood (4)
                     nbsOdsysTrapPsIInLevelBad 1.3.6.1.4.1.629.228.100.0.80
Sent when power supply's nbsOdsysPsIInLevel changes to anything but statusGood (4)
                     nbsOdsysTrapPsIInLevelOk 1.3.6.1.4.1.629.228.100.0.81
Sent when power supply's nbsOdsysPsIInLevel changes to statusGood (4)
                     nbsOdsysTrapPsIOutLevelBad 1.3.6.1.4.1.629.228.100.0.90
Sent when power supply's nbsOdsysPsIOutLevel changes to anything but statusGood (4)
                     nbsOdsysTrapPsIOutLevelOk 1.3.6.1.4.1.629.228.100.0.91
Sent when power supply's nbsOdsysPsIOutLevel changes to statusGood (4)
                     nbsOdsysTrapCcFailed 1.3.6.1.4.1.629.228.100.0.131
Triggered when nbsOdsysCcOperationalStatus transitions to bad (2)
                     nbsOdsysTrapCcRestored 1.3.6.1.4.1.629.228.100.0.132
Triggered when nbsOdsysCcOperationalStatus transitions to good (3)
                     nbsOdsysTrapCcRemoved 1.3.6.1.4.1.629.228.100.0.133
Triggered when control card is removed from chassis
                     nbsOdsysTrapCcInserted 1.3.6.1.4.1.629.228.100.0.134
Triggered when control card is inserted into chassis