Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 microsens 1.3.6.1.4.1.3181
Microsens private NOTIFICATION for Generation 6 Software Platform
           managedSwitches 1.3.6.1.4.1.3181.10
                 g6 1.3.6.1.4.1.3181.10.6
                     g6TrapGroup 1.3.6.1.4.1.3181.10.6.1
                         g6Trap 1.3.6.1.4.1.3181.10.6.1.1
                             g6TrapDebug 1.3.6.1.4.1.3181.10.6.1.1.3
Internal Debug Messages.
                             g6TrapAliveTest 1.3.6.1.4.1.3181.10.6.1.1.4
Can be used to check out event and notification system with no effect to the system operation.
                             g6TrapFirmwareUpdateOk 1.3.6.1.4.1.3181.10.6.1.1.5
Firmware installation has successfully taken place.
                             g6TrapFirmwareUpdateFail 1.3.6.1.4.1.3181.10.6.1.1.6
Firmware installation has FAILED.
                             g6TrapLicenseViolation 1.3.6.1.4.1.3181.10.6.1.1.7
Firmware is used for which no license has been granted. Please contact sales representant.
                             g6TrapColdStart 1.3.6.1.4.1.3181.10.6.1.1.8
The device has booted. Data transmission was interrupted.
                             g6TrapWarmStart 1.3.6.1.4.1.3181.10.6.1.1.9
The device has (partially) booted without interupting data transmission services.
                             g6TrapFactoryReset 1.3.6.1.4.1.3181.10.6.1.1.10
Configuration factory reset is executed via local push button on the device.
                             g6TrapConfigurationLoaded 1.3.6.1.4.1.3181.10.6.1.1.11
All or a specific configuration file(s) has been restored and activated.
                             g6TrapChangeConfig 1.3.6.1.4.1.3181.10.6.1.1.12
A configuration parameter has been modified and activated.
                             g6TrapChangeOfflineConfig 1.3.6.1.4.1.3181.10.6.1.1.13
An offline configuration parameter has been modified. The running system is not affected.
                             g6TrapActionResponse 1.3.6.1.4.1.3181.10.6.1.1.14
Not a customer event. Contains the reponse string to an action command.
                             g6TrapCommitConfig 1.3.6.1.4.1.3181.10.6.1.1.15
Not a customer event. Recent configuration changes should now be stored and activated.
                             g6TrapPowerSupplyOk 1.3.6.1.4.1.3181.10.6.1.1.16
Power supply has been restored. Applies to units with redundant supplies only.
                             g6TrapPowerSupplyFail 1.3.6.1.4.1.3181.10.6.1.1.17
Power supply has FAILED. Applies to units with redundant supplies only.
                             g6TrapLogin 1.3.6.1.4.1.3181.10.6.1.1.18
An operator has logged onto the system.
                             g6TrapLogout 1.3.6.1.4.1.3181.10.6.1.1.19
An operator has logged off from the system.
                             g6TrapLoginAttempt 1.3.6.1.4.1.3181.10.6.1.1.20
An operator login has failed due to invalid login or password.
                             g6TrapLinkUp 1.3.6.1.4.1.3181.10.6.1.1.21
A port has gone online and is ready to transport data.
                             g6TrapLinkDown 1.3.6.1.4.1.3181.10.6.1.1.22
A port has gone down. Data transport on this port is no longer possible.
                             g6TrapRingNormal 1.3.6.1.4.1.3181.10.6.1.1.23
A ring is back to normal operation. Protection is available.
                             g6TrapRingBackup 1.3.6.1.4.1.3181.10.6.1.1.24
A ring has switched to the redundant backup path.
                             g6TrapRingFailure 1.3.6.1.4.1.3181.10.6.1.1.25
A ring has FAILED. Normal and backup path are unavailable.
                             g6TrapCouplingState 1.3.6.1.4.1.3181.10.6.1.1.26
Coupling controller state change.
                             g6TrapTemperatureOk 1.3.6.1.4.1.3181.10.6.1.1.27
Operating temperature is within acceptable limits.
                             g6TrapTemperatureWarning 1.3.6.1.4.1.3181.10.6.1.1.28
Operating temperature is low or high. Performance my be degraded. Do not run under this condition for prolonged time.
                             g6TrapTemperatureFailure 1.3.6.1.4.1.3181.10.6.1.1.29
Operating temperature is too low or too high. The unit may switch itself off to protect itself anytime soon.
                             g6TrapMacAccepted 1.3.6.1.4.1.3181.10.6.1.1.30
A MAC address has been authorized.
                             g6TrapMacAuthError 1.3.6.1.4.1.3181.10.6.1.1.31
MAC authorization error.
                             g6TrapMacBlocked 1.3.6.1.4.1.3181.10.6.1.1.32
A MAC address has been blocked.
                             g6TrapMacBlockedVlan 1.3.6.1.4.1.3181.10.6.1.1.33
A MAC address has been blocked. Assigned to unauthorized VLAN.
                             g6TrapMacDisconnected 1.3.6.1.4.1.3181.10.6.1.1.34
A MAC address has been disconnected.
                             g6TrapSfpInserted 1.3.6.1.4.1.3181.10.6.1.1.35
An SFP (pluggable optical or electrical port module) has been inserted.
                             g6TrapSfpRemoved 1.3.6.1.4.1.3181.10.6.1.1.36
An SFP (pluggable optical or electrical port module) has been removed from the device.
                             g6TrapSfpSignalPresent 1.3.6.1.4.1.3181.10.6.1.1.37
An SFP (pluggable optical or electrical port module) has detected an optical receive signal.
                             g6TrapSfpSignalLoss 1.3.6.1.4.1.3181.10.6.1.1.38
An SFP (pluggable optical or electrical port module) has lost its receive signal.
                             g6TrapSfpSignalChange 1.3.6.1.4.1.3181.10.6.1.1.39
An SFP (pluggable optical or electrical port module) has detected a change in the optical input power level.
                             g6TrapSfpMismatch 1.3.6.1.4.1.3181.10.6.1.1.40
An SFP (pluggable optical or electrical port module) has been inserted which does not match the required feature(s).
                             g6TrapPoeConnect 1.3.6.1.4.1.3181.10.6.1.1.41
A POE (Power over Ethernet) device is connected an powered.
                             g6TrapPoeVoltage 1.3.6.1.4.1.3181.10.6.1.1.42
The POE (Power over Ethernet) operating voltage is too low.
                             g6TrapPoeError 1.3.6.1.4.1.3181.10.6.1.1.43
A POE (Power over Ethernet) error has occurred.
                             g6TrapPoeClassmismatch 1.3.6.1.4.1.3181.10.6.1.1.44
A POE (Power over Ethernet) powered device requires a power level not enabled or available at this port.
                             g6TrapPoeDisconnect 1.3.6.1.4.1.3181.10.6.1.1.45
A POE (Power over Ethernet) device has been disconnected.
                             g6TrapNtpFail 1.3.6.1.4.1.3181.10.6.1.1.46
The NTP client (Network Time Protocol) has a failure condition.
                             g6TrapHardwareError 1.3.6.1.4.1.3181.10.6.1.1.47
A hardware error has been detected.
                             g6TrapSoftwareError 1.3.6.1.4.1.3181.10.6.1.1.48
A software error has occured.
                             g6TrapButtonPressed 1.3.6.1.4.1.3181.10.6.1.1.49
System button pressed.
                             g6TrapInputSignalNormal 1.3.6.1.4.1.3181.10.6.1.1.67
An external input signal has been deactivated and returned to normal state.
                             g6TrapInputSignalActivated 1.3.6.1.4.1.3181.10.6.1.1.68
An external input signal has been activated.
                             g6TrapOutputRelayNormal 1.3.6.1.4.1.3181.10.6.1.1.69
A relay output signal has been deactivated and returned to normal state.
                             g6TrapOutputRelayActivated 1.3.6.1.4.1.3181.10.6.1.1.70
An external input signal has been deactivated and returned to normal state.
                             g6TrapPacketIntercepted 1.3.6.1.4.1.3181.10.6.1.1.71
Special filter has intercepted a data packet.
                             g6TrapScriptUnitPositive 1.3.6.1.4.1.3181.10.6.1.1.72
A positive unit related user defined event created by script or app.
                             g6TrapScriptUnitNegative 1.3.6.1.4.1.3181.10.6.1.1.73
A negative unit related user defined event created by script or app.
                             g6TrapScriptPortPositive 1.3.6.1.4.1.3181.10.6.1.1.74
A positive port related user defined event created by script or app.
                             g6TrapScriptPortNegative 1.3.6.1.4.1.3181.10.6.1.1.75
A negative port related user defined event created by script or app.
                             g6TrapScriptExecuted 1.3.6.1.4.1.3181.10.6.1.1.76
A user defined script execution started.
                             g6TrapScriptError 1.3.6.1.4.1.3181.10.6.1.1.77
Script execution error of a user defined script.
                             g6TrapLoopRemoved 1.3.6.1.4.1.3181.10.6.1.1.78
Cable loop removed. Port unblocked.
                             g6TrapLoopDetected 1.3.6.1.4.1.3181.10.6.1.1.79
Cable loop detected. Port blocked.
                             g6TrapLacpConnect 1.3.6.1.4.1.3181.10.6.1.1.80
Aggregated link established.
                             g6TrapLacpDisconnect 1.3.6.1.4.1.3181.10.6.1.1.81
Aggregated link down.
                             g6TrapAppInstalled 1.3.6.1.4.1.3181.10.6.1.1.82
App installed ok.
                             g6TrapAppInstallationFail 1.3.6.1.4.1.3181.10.6.1.1.83
App installation has failed.
                             g6TrapAppDeinstalled 1.3.6.1.4.1.3181.10.6.1.1.84
App deinstalled.
                             g6TrapCableChangeDetected 1.3.6.1.4.1.3181.10.6.1.1.85
Change in cable termination detected.
                             g6TrapImplausibleConfig 1.3.6.1.4.1.3181.10.6.1.1.86
Implausible configuration detected
                             g6TrapNetworkAttack 1.3.6.1.4.1.3181.10.6.1.1.87
Potential network attack detected
                             g6TrapModuleInserted 1.3.6.1.4.1.3181.10.6.1.1.88
A hardware module has been inserted into the system.
                             g6TrapModuleRemoved 1.3.6.1.4.1.3181.10.6.1.1.89
A hardware module has been removed from the system.
                             g6TrapMsp1000UnitPositive 1.3.6.1.4.1.3181.10.6.1.1.90
A positive MSP1000 unit related event has occured.
                             g6TrapMsp1000UnitNegative 1.3.6.1.4.1.3181.10.6.1.1.91
A negative MSP1000 unit related event has occured.
                             g6TrapMsp1000PortPositive 1.3.6.1.4.1.3181.10.6.1.1.92
A positive MSP1000 port related event has occured.
                             g6TrapMsp1000PortNegative 1.3.6.1.4.1.3181.10.6.1.1.93
A negative MSP1000 port related event has occured.
                             g6TrapBackupTerminated 1.3.6.1.4.1.3181.10.6.1.1.94
Backup path not required.
                             g6TrapBackupEngaged 1.3.6.1.4.1.3181.10.6.1.1.95
Backup path has been engaged.
                             g6TrapBackupFailure 1.3.6.1.4.1.3181.10.6.1.1.96
Backup path could not be completed.
                             g6TrapFanOk 1.3.6.1.4.1.3181.10.6.1.1.97
Cooling fan operating normally.
                             g6TrapFanDegraded 1.3.6.1.4.1.3181.10.6.1.1.98
Cooling fan degraded. Replace fan soon.
                             g6TrapFanFailure 1.3.6.1.4.1.3181.10.6.1.1.99
Cooling fan failed. Replace fan immediately
                             g6TrapIncomingAlert 1.3.6.1.4.1.3181.10.6.1.1.100
Externally received HTTP_GET_REQUEST or received SNMP TRAP.
                             g6TrapCableTerminationEstablished 1.3.6.1.4.1.3181.10.6.1.1.101
Cable termination established. Possible reason: A terminated remote device was connected to the cable.
                             g6TrapCableTerminationLost 1.3.6.1.4.1.3181.10.6.1.1.102
Cable termination lost. Possible reason: A terminated remote device was disconnected from the cable or the cable was locally unplugged.
                             g6TrapTerminalServerConnected 1.3.6.1.4.1.3181.10.6.1.1.103
Terminal server connected foreign host to local serial port.
                             g6TrapTerminalServerDisconnected 1.3.6.1.4.1.3181.10.6.1.1.104
Terminal server disconnected foreign host from local serial port.
                             g6TrapTerminalServerFail 1.3.6.1.4.1.3181.10.6.1.1.105
Terminal server failed in connecting foreign host to local serial port.
                             g6TrapSensorGroupChange 1.3.6.1.4.1.3181.10.6.1.1.108
Sensor group values have changed.
                             g6TrapActorGroupChangeRequest 1.3.6.1.4.1.3181.10.6.1.1.110
Actor group is requested to change to a new value.
                             g6TrapRegisterSmartDevice 1.3.6.1.4.1.3181.10.6.1.1.111
A new smart device is registered.
                             g6TrapUpdateSmartDevice 1.3.6.1.4.1.3181.10.6.1.1.112
A smart device has changed its status.
                             g6TrapRegisterSmartAttribute 1.3.6.1.4.1.3181.10.6.1.1.115
A new smart attribute is registered.
                             g6TrapUnregisterSmartDevice 1.3.6.1.4.1.3181.10.6.1.1.117
A smart device is unregistered.
                             g6TrapUnregisterSmartAttribute 1.3.6.1.4.1.3181.10.6.1.1.118
A smart attribute is unregistered.
                             g6TrapSingleActorChange 1.3.6.1.4.1.3181.10.6.1.1.119
An individual actor is set to a new value.
                             g6TrapActorGroupChanged 1.3.6.1.4.1.3181.10.6.1.1.120
An actor group has changed to a new value.
                             g6TrapSmartOfficeInitializing 1.3.6.1.4.1.3181.10.6.1.1.121
Smart Office is being initialized.
                             g6TrapSmartOfficeStarted 1.3.6.1.4.1.3181.10.6.1.1.122
Smart Office is started and ready.
                             g6TrapSmartOfficeStopped 1.3.6.1.4.1.3181.10.6.1.1.123
Smart Office is being stopped.
                             g6TrapSmartOfficeError 1.3.6.1.4.1.3181.10.6.1.1.124
A Smart Office error has occured.
                             g6TrapOtdrMeasurements 1.3.6.1.4.1.3181.10.6.1.1.125
An OTDR measurement has taken place and detected a change in the optical characteristics of the cable.
                         g6TrapObjects 1.3.6.1.4.1.3181.10.6.1.2
                             g6TrapObjEventName 1.3.6.1.4.1.3181.10.6.1.2.1 displaystring read-only
Event name as text string.
                             g6TrapObjGroupName 1.3.6.1.4.1.3181.10.6.1.2.2 integer read-only
Event group as text string. Enumeration: 'app': 21, 'lacp': 20, 'smartoffice': 29, 'ring': 15, 'poe': 14, 'temperature': 11, 'script': 18, 'firmware': 5, 'system': 6, 'signals': 17, 'internal': 0, 'test': 3, 'config': 7, 'msp1000': 24, 'power': 10, 'ntp': 16, 'auth': 9, 'terminalserver': 28, 'link': 12, 'sfp': 13, 'messaging': 27, 'security': 23, 'reset': 4, 'cable': 22, 'filter': 19, 'debug': 2, 'fan': 26, 'login': 8, 'backup': 25.
                             g6TrapObjRelevance 1.3.6.1.4.1.3181.10.6.1.2.3 integer read-only
pos neg info Enumeration: 'positive': 0, 'negative': 1, 'information': 2.
                             g6TrapObjSeverity 1.3.6.1.4.1.3181.10.6.1.2.4 integer read-only
Severity level of this event. Enumeration: 'info': 2, 'notice': 3, 'emergency': 8, 'alert': 7, 'disabled': 0, 'warning': 4, 'critical': 6, 'error': 5, 'debug': 1.
                             g6TrapObjSource 1.3.6.1.4.1.3181.10.6.1.2.5 integer read-only
Unit or port related event. Enumeration: 'port': 1, 'unit': 0.
                             g6TrapObjSysName 1.3.6.1.4.1.3181.10.6.1.2.6 displaystring read-only
User defined system name of the device originating this event.
                             g6TrapObjPortId 1.3.6.1.4.1.3181.10.6.1.2.7 integer32 read-only
Port identification in snmp compliant integer format. Value is calculated as (slot * 100) + port.
                             g6TrapObjPortString 1.3.6.1.4.1.3181.10.6.1.2.8 displaystring read-only
Port identification in slot/port notation.
                             g6TrapObjPortAlias 1.3.6.1.4.1.3181.10.6.1.2.9 displaystring read-only
Port identification using a possible user assigned alias or nickname.
                             g6TrapObjDescription 1.3.6.1.4.1.3181.10.6.1.2.10 displaystring read-only
Detailed human readable full description of the event.
                             g6TrapObjMac 1.3.6.1.4.1.3181.10.6.1.2.11 macaddress read-only
MAC address related with authentication trap.
                             g6TrapObjVlanId 1.3.6.1.4.1.3181.10.6.1.2.12 integer32 read-only
Associated VLAN id.
                             g6TrapObjOfficeGroupName 1.3.6.1.4.1.3181.10.6.1.2.13 displaystring read-only
SmartOffice actor or sensor group name.
                             g6TrapObjAvgValue 1.3.6.1.4.1.3181.10.6.1.2.14 displaystring read-only
SmartOffice group data value. Contains the average value of all elements in the same group
                             g6TrapObjTotalValue 1.3.6.1.4.1.3181.10.6.1.2.15 displaystring read-only
SmartOffice group data value. Contains the total value of all elements in the same group