Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 polPowerOverLan 1.3.6.1.4.1.7428
           products 1.3.6.1.4.1.7428.1
               description 1.3.6.1.4.1.7428.1.1
                   sysObjectID 1.3.6.1.4.1.7428.1.1.1
                       midspanUnknown 1.3.6.1.4.1.7428.1.1.1.1
                       midspan6portAC 1.3.6.1.4.1.7428.1.1.1.2
                       midspan6portACDC 1.3.6.1.4.1.7428.1.1.1.3
                       midspan12portAC 1.3.6.1.4.1.7428.1.1.1.4
                       midspan12portACDC 1.3.6.1.4.1.7428.1.1.1.5
                       midspan24portAC 1.3.6.1.4.1.7428.1.1.1.6
                       midspan24portACDC 1.3.6.1.4.1.7428.1.1.1.7
                       midspan48portAC 1.3.6.1.4.1.7428.1.1.1.8
                       midspan48portACDC 1.3.6.1.4.1.7428.1.1.1.9
                       midspan6portHPAC 1.3.6.1.4.1.7428.1.1.1.10
                       midspan6portHPACDC 1.3.6.1.4.1.7428.1.1.1.11
                       midspan12portHPAC 1.3.6.1.4.1.7428.1.1.1.12
                       midspan12portHPACDC 1.3.6.1.4.1.7428.1.1.1.13
                       midspanGigabit6portAC 1.3.6.1.4.1.7428.1.1.1.14
                       midspanGigabit12portAC 1.3.6.1.4.1.7428.1.1.1.15
                       midspanGigabit24portAC 1.3.6.1.4.1.7428.1.1.1.16
                       midspanHiPoEGigabit6portAC 1.3.6.1.4.1.7428.1.1.1.17
                       midspanHiPoEGigabit12portAC 1.3.6.1.4.1.7428.1.1.1.18
                       midspanHiPoEGigabit24portAC 1.3.6.1.4.1.7428.1.1.1.19
                       midspanHiPoEATGigabit6portAC 1.3.6.1.4.1.7428.1.1.1.20
                       midspanHiPoEATGigabit12portACDC 1.3.6.1.4.1.7428.1.1.1.21
                       midspanHiPoEATGigabit24portACDC 1.3.6.1.4.1.7428.1.1.1.22
                       midspan4PairATGigabit6portACDC 1.3.6.1.4.1.7428.1.1.1.23
                       midspan4PairATGigabit12portACDC 1.3.6.1.4.1.7428.1.1.1.24
                       midspanHiPoEATGigabit6portDC 1.3.6.1.4.1.7428.1.1.1.25
                       midspanHiPoEATGigabit12portDC 1.3.6.1.4.1.7428.1.1.1.26
                       midspanHiPoEATGigabit24portDC 1.3.6.1.4.1.7428.1.1.1.27
                       midspan4PairATGigabit24portACDC 1.3.6.1.4.1.7428.1.1.1.28
                       midspanEEPoEGigabit24portACDC 1.3.6.1.4.1.7428.1.1.1.29
                       midspanPoHGigabit6portACDC 1.3.6.1.4.1.7428.1.1.1.30
                       midspanPoHGigabit12portACDC 1.3.6.1.4.1.7428.1.1.1.31
                       midspanPoHGigabit24portACDC 1.3.6.1.4.1.7428.1.1.1.32
               pseDevice 1.3.6.1.4.1.7428.1.2
                   portObjects 1.3.6.1.4.1.7428.1.2.1
                       portTable 1.3.6.1.4.1.7428.1.2.1.1 no-access
A table of objects that display and control the power characteristics of power Ethernet ports on a Power Source Entity (PSE) device. This group will be implemented in managed power Ethernet switches and mid-span devices. Values of all read-write objects in this table are persistent at restart/reboot.
                           portEntry 1.3.6.1.4.1.7428.1.2.1.1.1 no-access
A set of objects that display and control the power characteristics of a power Ethernet PSE port.
                               portGroupIndex 1.3.6.1.4.1.7428.1.2.1.1.1.1 integer32 no-access
This variable uniquely identifies the group containing the port to which a power Ethernet PSE is connected. Group means box in the stack, module in a rack and the value 1 MUST be used for non-modular devices.
                               portIndex 1.3.6.1.4.1.7428.1.2.1.1.1.2 integer32 no-access
This variable uniquely identifies the power Ethernet PSE port within group portGroupIndex to which the power Ethernet PSE entry is connected.
                               portConsumptionPower 1.3.6.1.4.1.7428.1.2.1.1.1.3 gauge32 read-only
A read-only value indicates the measured usage power expressed in Watts for a specific port
                               portMaxPower 1.3.6.1.4.1.7428.1.2.1.1.1.4 integer32 read-write
Read/Write maximum power consumption that PD device may consume in Watts NOTE: 1. For Midspan 60xx,60xxG,6500 series, Max PD power consumption = 17Watt 2. For Midspan 70xxG series, Max PD power consumption = 30Watt 3 .For Midspan 80xx series, this parameter is read-only !! 4. For Midspan 90xxG series, Max PD power consumption = 30/36Watt 5. For Midspan 95xxG series, Max PD power consumption = 60/72Watt (four pair) or 30/36Watt (two pair) 6. For Midspan 55xxG series, Max PD power consumption = 30/36Watt
                               portType 1.3.6.1.4.1.7428.1.2.1.1.1.5 integer read-write
Enable/Disable Four-pair/EEPoE PoE Read : Applicable to all Midspan series Write: Applicable only to 95xxG/55xxG Midspan series twopair (1) Two-pair PoE port capable of providing up to 16.8Watt or 30-36Watt. fourpair (2) Four-pair/EEPoE-mode PoE port capable of providing up to 60-72Watt (95xxG) or 30-36W (55xxG). Enumeration: 'fourpair': 2, 'twopair': 1.
                   mainObjects 1.3.6.1.4.1.7428.1.2.2
                       mainPseTable 1.3.6.1.4.1.7428.1.2.2.1 no-access
A table of objects that display and control attributes of the main PSE device.
                           mainPseEntry 1.3.6.1.4.1.7428.1.2.2.1.1 no-access
A set of objects that display and control the Main PSE device.
                               mainGroupIndex 1.3.6.1.4.1.7428.1.2.2.1.1.1 integer32 no-access
This variable uniquely identifies the group to which power Ethernet PSE is connected. Group means (box in the stack, module in a rack) and the value 1 MUST be used for non-modular devices.
                               mainVoltage 1.3.6.1.4.1.7428.1.2.2.1.1.2 gauge32 read-only
Power Supply Voltage in Volt.
                               mainDetectionMethod 1.3.6.1.4.1.7428.1.2.2.1.1.3 integer read-write
Read/Write PD device detection method (802.3af / 802.3af+Legacy). Enumeration: 'ieee8023afatandlegacy': 2, 'ieee8023afat': 1.
                               mainPowerUsageBudget 1.3.6.1.4.1.7428.1.2.2.1.1.4 integer32 read-write
Allow external SNMP manager to limit maximum power that all PD's may consume Whenever total power consumption exceeds maximum power, Midspan may turn off automatically Low priority and High priority PSE ports. Percentage Value refers to Midspan maximum power.
                               mainPSEMaxPower 1.3.6.1.4.1.7428.1.2.2.1.1.5 gauge32 read-only
Maximum power that Midspan can provide (Watt), after including power budget percentage limitation. Example: Midspan maximum power without power limit = 860Watt, and Power Limit = 50% mainPSEMaxPower = 430Watt
                               highPowerLegacyPDSupport 1.3.6.1.4.1.7428.1.2.2.1.1.6 integer read-write
Applicable only for Midspan 90xxG series enable (1) - Power Cisco 125x access point (pre 802.3at legacy high power PD device). disable(2) - Power only 802.3at compliant devices. notsupported(3) - SNMP GET result for Midspan which doesn't support this feature Enumeration: 'notsupported': 3, 'enable': 1, 'disable': 2.
                               highPowerExtendedPortPower 1.3.6.1.4.1.7428.1.2.2.1.1.7 integer read-write
Applicable only for Midspan 90xxG/55xxG series enable (1) - Extend maximum power to PD device beyond 802.3at specification. disable(2) - Maximum power to PD device per 802.3at specification. notsupported(3) - SNMP GET result for Midspan which doesn't support this feature Enumeration: 'notsupported': 3, 'enable': 1, 'disable': 2.
                               powerBackupStatus 1.3.6.1.4.1.7428.1.2.2.1.1.8 integer read-only
Applicable only for Midspan 90xxG/95xxG/55xxG series standalone - Midspan isn't connected to any power backup device powerbackupbyrps - Redundant power supply (RPS) backup Midspan device powerbackupbymidspan - Two Midspan devices backup each other incompatiblepowerbackupdevice - Midspan was connected to incompatible power backup device. For example RPS 430Watt to Midspan 950Watt Enumeration: 'powerbackupbymidspan': 3, 'incompatiblepowerbackupdevice': 4, 'powerbackupbyrps': 2, 'standalone': 1.
                               internalPowerSourceStatus 1.3.6.1.4.1.7428.1.2.2.1.1.9 integer read-only
Applicable only for Midspan 90xxG/95xxG/55xxG series ok(1) - Internal Power Source is OK fail(2) - Internal Power Source failure Enumeration: 'fail': 2, 'ok': 1.
                               externalPowerSourceStatus 1.3.6.1.4.1.7428.1.2.2.1.1.10 integer read-only
Applicable only for Midspan 90xxG/95xxG/55xxG series ok(1) - External Power Source is OK fail(2) - External Power Source failure notsupported(3) - SNMP GET result for Midspan which doesn't support this feature Enumeration: 'fail': 2, 'notsupported': 3, 'ok': 1.
                               temperature 1.3.6.1.4.1.7428.1.2.2.1.1.11 integer read-only
Unit temperature - Applicable only for Midspan 95xxG series
                               temperatureformat 1.3.6.1.4.1.7428.1.2.2.1.1.12 integer read-write
Unit temperature format - Applicable only for Midspan 95xxG series Celcius(1) - Report unit temperature in Celcius Fahrenheit(2) - Report unit temperature in Fahrenheit NotSupported(3) - No temperature sensor inside the Midspan unit Enumeration: 'fahrenheit': 2, 'notsupported': 3, 'celcius': 1.
               poeNotifications 1.3.6.1.4.1.7428.1.3
                   powerBackupStatusNotification 1.3.6.1.4.1.7428.1.3.1
Applicable only for Midspan 90xxG/95xxG/55xxG series This Notification reports power backup status change, and whenever incompatible power backup source is connected (as RPS 430Watt to Midspan 950Watt)
                   internalPowerSourceStatusNotification 1.3.6.1.4.1.7428.1.3.2
Applicable only for Midspan 90xxG/95xxG/55xxG series This Notification reports internal Power Source failure
                   externalPowerSourceStatusNotification 1.3.6.1.4.1.7428.1.3.3
Applicable only for Midspan 90xxG/95xxG/55xxG series This Notification reports external Power Source failure