ME1200-UPNP-MIB: View SNMP OID List / Download MIB

VENDOR: CISCO


 Home MIB: ME1200-UPNP-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 me1200UpnpMib 1.3.6.1.4.1.9.9.815.1.52
This is a private version of UPnP
       me1200UpnpMibObjects 1.3.6.1.4.1.9.9.815.1.52.1
           me1200UpnpConfig 1.3.6.1.4.1.9.9.815.1.52.1.2
               me1200UpnpConfigGlobals 1.3.6.1.4.1.9.9.815.1.52.1.2.1
                   me1200UpnpConfigGlobalsMode 1.3.6.1.4.1.9.9.815.1.52.1.2.1.1 truthvalue read-write
Global mode of UPnP. true(1) is to enable the functions of HTTPS and false(2) is to disable it.
                   me1200UpnpConfigGlobalsTtl 1.3.6.1.4.1.9.9.815.1.52.1.2.1.2 me1200unsigned8 read-write
The TTL value is used by UPnP to send SSDP advertisement messages.Valid values are in the range 1 to 255.
                   me1200UpnpConfigGlobalsAdvertisingDuration 1.3.6.1.4.1.9.9.815.1.52.1.2.1.3 integer32 read-write
The duration, carried in SSDP packets, is used to inform a control point or control points how often it or they should receive an SSDP advertisement message from this switch. If a control point does not receive any message within the duration, it will think that the switch no longer exists. Due to the unreliable nature of UDP, in the standard it is recommended that such refreshing of advertisements to be done at less than one-half of the advertising duration. In the implementation, the switch sends SSDP messages periodically at the interval one-half of the advertising duration minus 30 seconds. Valid values are in the range 100 to 86400.
       me1200UpnpMibConformance 1.3.6.1.4.1.9.9.815.1.52.2
           me1200UpnpMibCompliances 1.3.6.1.4.1.9.9.815.1.52.2.1
               me1200UpnpMibCompliance 1.3.6.1.4.1.9.9.815.1.52.2.1.1
The compliance statement for the implementation.
           me1200UpnpMibGroups 1.3.6.1.4.1.9.9.815.1.52.2.2
               me1200UpnpConfigGlobalsInfoGroup 1.3.6.1.4.1.9.9.815.1.52.2.2.1
A collection of objects suitable for bulk operations.