LUM-OCM-MIB: View SNMP OID List / Download MIB
VENDOR: LUMENTIS AB
Home | MIB: LUM-OCM-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
lumOcmMIBModule | 1.3.6.1.4.1.8708.1.1.33 | |||
lumOcmConfs | 1.3.6.1.4.1.8708.2.33.1 | |||
lumOcmGroups | 1.3.6.1.4.1.8708.2.33.1.1 | |||
lumOcmCompl | 1.3.6.1.4.1.8708.2.33.1.2 | |||
lumOcmMinimalGroups | 1.3.6.1.4.1.8708.2.33.1.3 | |||
lumOcmMinimalCompl | 1.3.6.1.4.1.8708.2.33.1.4 | |||
lumOcmMIBObjects | 1.3.6.1.4.1.8708.2.33.2 | |||
ocmGeneral | 1.3.6.1.4.1.8708.2.33.2.1 | |||
ocmGeneralLastChangeTime | 1.3.6.1.4.1.8708.2.33.2.1.1 |
The time when the configuration of the MIB was last changed. |
||
ocmGeneralStateLastChangeTime | 1.3.6.1.4.1.8708.2.33.2.1.2 |
The time when the state of the MIB was last changed. |
||
ocmGeneralOcmIfTableSize | 1.3.6.1.4.1.8708.2.33.2.1.3 |
Size of table |
||
ocmGeneralOcmChannelTableSize | 1.3.6.1.4.1.8708.2.33.2.1.4 |
Size of table |
||
ocmIfList | 1.3.6.1.4.1.8708.2.33.2.2 | |||
ocmIfTable | 1.3.6.1.4.1.8708.2.33.2.2.1 |
The interface list. |
||
1.3.6.1.4.1.8708.2.33.2.2.1.1 |
An entry in the interface list. |
|||
ocmIfIndex | 1.3.6.1.4.1.8708.2.33.2.2.1.1.1 |
An arbitrary index assigned to each entry. |
||
ocmIfName | 1.3.6.1.4.1.8708.2.33.2.2.1.1.2 |
The management name of the interface, for example ocm:1:2:1, where the first number indicates sub-rack, the second slot number and the third is the port number. Examples: ocm:s:s:p - Optical channel module interface |
||
ocmIfDescr | 1.3.6.1.4.1.8708.2.33.2.2.1.1.3 |
User configurable label. |
||
ocmIfSubrack | 1.3.6.1.4.1.8708.2.33.2.2.1.1.4 |
The number of the subrack where the interface is located. |
||
ocmIfSlot | 1.3.6.1.4.1.8708.2.33.2.2.1.1.5 |
The number of the slot where the interface is located. |
||
ocmIfRxPort | 1.3.6.1.4.1.8708.2.33.2.2.1.1.6 |
The number of the port where the RX-side of the interface is located. |
||
ocmIfInvPhysIndexOrZero | 1.3.6.1.4.1.8708.2.33.2.2.1.1.7 |
The row in the invPhysTable for this interface. Set to 0 if not known. |
||
ocmIfAdminStatus | 1.3.6.1.4.1.8708.2.33.2.2.1.1.8 |
The administrative state for the interface. down - The interface should be inactive. service - The interface is activated but alarms are suppressed. Intended for use during service or re-configuration. When service is concluded adminStatus should be set to up again. up - The interface should be activated when it becomes available. Alarms are not suppressed. |
||
ocmIfOperStatus | 1.3.6.1.4.1.8708.2.33.2.2.1.1.9 |
The operational state for the interface. notPresent - The physical resources are not available. down - The interface is de-activated or the are faults preventing it from going to the up-state. up - The interface is operational. |
||
ocmIfPowerThreshold | 1.3.6.1.4.1.8708.2.33.2.2.1.1.12 |
The threshold for power levels. If the measured power level is below the threshold, it is regarded as no signal. For OCM8p: Default -13dBm Range -35 to 100dBm For OCM2p: |
||
ocmIfUpdateLastChangeTime | 1.3.6.1.4.1.8708.2.33.2.2.1.1.13 |
The time when the last measurement was done. |
||
ocmIfConnectedSubrack | 1.3.6.1.4.1.8708.2.33.2.2.1.1.14 |
The number of the subrack where the connected interface is located. (0 is not valid) |
||
ocmIfConnectedSlot | 1.3.6.1.4.1.8708.2.33.2.2.1.1.15 |
The number of the slot where the connected interface is located. (not possible to set 0, 1, 19-22, oa/roadm can not be placed in those slots) |
||
ocmIfConnectedPort | 1.3.6.1.4.1.8708.2.33.2.2.1.1.16 |
The number of the connected port. (the tx port number). 1 or 3 for OA, 5 for 1x2ROADM/100G/50G, 9 for 1x4ROADM/100G, 17 for 1x8ROADM/50G, 1 for OA26C, 5 for OARAED21HG 81 for MDU40. and 1 to 82 for other boards. |
||
ocmIfActivePort | 1.3.6.1.4.1.8708.2.33.2.2.1.1.17 |
The number of the active port. Only valid when commissioning mode. |
||
ocmIfControlMode | 1.3.6.1.4.1.8708.2.33.2.2.1.1.18 |
What mode the ocm is in. normal - the switch toggle every hour and measure both ports. commissioning - the switch is set to one active port and measurement is made continuously on this port. After 15 minutes it will change back to normal mode. Note that it is not possible to get updated values on port that is not chosen as active during commissioning mode. |
||
ocmIfReferenceTime | 1.3.6.1.4.1.8708.2.33.2.2.1.1.21 |
Time where reference values were saved. |
||
ocmIfSwitchFailure | 1.3.6.1.4.1.8708.2.33.2.2.1.1.22 |
Switch failure. A: The switch is stuck and it is not possible to change port. It is not sure if it the values comes from the expected port. D: The switch works as expected. |
||
ocmIfDataSourceNotDefined | 1.3.6.1.4.1.8708.2.33.2.2.1.1.23 |
Data source not defined, A: No connected slot, connected subrack nor connected port is defined. D: Connected slot, connected subrack and connected port is ok. |
||
ocmIfCommissioningMode | 1.3.6.1.4.1.8708.2.33.2.2.1.1.24 |
Data source not defined, A: Commissioning mode is used D: Normal mode |
||
ocmIfModuleFailure | 1.3.6.1.4.1.8708.2.33.2.2.1.1.25 |
The module HW has detected a failure. A: The module has failed D: The module is OK again |
||
ocmIfConfigurationCommand | 1.3.6.1.4.1.8708.2.33.2.2.1.1.26 |
Select which control mode to use. normal - the switch toggle every hour and measure both ports. commissioning - the switch is set to one port while adjusting surrounding boards. |
||
ocmIfChangeConnectedPort | 1.3.6.1.4.1.8708.2.33.2.2.1.1.27 |
Select which monitor port that is connected to this ocm port. |
||
ocmIfSaveReference | 1.3.6.1.4.1.8708.2.33.2.2.1.1.28 |
Save current measurement as reference values |
||
ocmIfPowerOffset | 1.3.6.1.4.1.8708.2.33.2.2.1.1.29 |
An offset value added to all power levels to get an accurate presentation of channel powers at the line port. Generally offset values depends upon board type connected. oa - 20.0 roadm - 17.0 oa26c - 20.0 mdu40 - 20.0 other - 20.0 oaraed21hg - 20.0 oaraed20lg - 20.0 OA boards have more accurate values for power offset named Monitor port insertion loss visible in the OA interface. Note however that the reference power level values are not affected by a change of this offset. A new reference calculation should be made after a change. |
||
ocmIfConnectedBoardType | 1.3.6.1.4.1.8708.2.33.2.2.1.1.30 |
What board type that is connected to the ocm. The power offset default value is changed based on the chosen board type. Please note that this function is not applicable for mdu40lite boards. |
||
ocmIfChangeConnectedBoardType | 1.3.6.1.4.1.8708.2.33.2.2.1.1.31 |
Select board type for the monitor port connected to this ocm port. |
||
ocmIfMaxPowerLevel | 1.3.6.1.4.1.8708.2.33.2.2.1.1.32 |
The maximum received power level for this port in units of 0.1 dBm. |
||
ocmIfMinPowerLevel | 1.3.6.1.4.1.8708.2.33.2.2.1.1.33 |
The minimum received power level for this port in units of 0.1 dBm. |
||
ocmIfDeltaPower | 1.3.6.1.4.1.8708.2.33.2.2.1.1.34 |
The difference between the maximum and the minimum received power level for this port in units of 0.1 dBm. |
||
ocmIfChangePowerThreshold | 1.3.6.1.4.1.8708.2.33.2.2.1.1.35 |
Select the power threshold for this ocm port. If the measured power level is below the threshold, it is regarded as no signal. |
||
ocmIfChangePowerOffset | 1.3.6.1.4.1.8708.2.33.2.2.1.1.36 |
Select the power offset for this ocm port. The power offset is a value added to all power levels to get an accurate presentation of channel powers at the line port. |
||
ocmIfPowerOffsetAdjustment | 1.3.6.1.4.1.8708.2.33.2.2.1.1.37 |
An offset adjustment added to the power offset to mitigate the effects of differences between actual power measured at the OCM and the configured power offset value. This adjustment allows the optical control loop to regulate with better precision. |
||
ocmIfSpacingMode | 1.3.6.1.4.1.8708.2.33.2.2.1.1.38 |
Spacing mode is configured for monitoring channel power with the channel spacing of 50GHz. spacing50GHz: interface with channels in 50 GHz intervals |
||
ocmIfHighInputPower | 1.3.6.1.4.1.8708.2.33.2.2.1.1.39 |
The OCM module has detected a high input power. A: OCM module has dectected high input power (above 20dBm) on particular port. D: Optical input power is within the limit (below 20dBm). |
||
ocmChannelList | 1.3.6.1.4.1.8708.2.33.2.3 | |||
ocmChannelTable | 1.3.6.1.4.1.8708.2.33.2.3.1 |
The channel list. |
||
1.3.6.1.4.1.8708.2.33.2.3.1.1 |
An entry in the channel list. |
|||
ocmChannelIndex | 1.3.6.1.4.1.8708.2.33.2.3.1.1.1 |
An arbitrary index assigned to each entry. |
||
ocmChannelName | 1.3.6.1.4.1.8708.2.33.2.3.1.1.2 |
The management name of the interface, for example ocm:1:2:1, where the first number indicates sub-rack, the second slot number and the third is the port number. Examples: ocm:s:s:p - Optical channel module interface |
||
ocmChannelFrequency | 1.3.6.1.4.1.8708.2.33.2.3.1.1.3 |
Freqency in hundreds of GHz (0.01 GHz). |
||
ocmChannelPowerLevel | 1.3.6.1.4.1.8708.2.33.2.3.1.1.4 |
The received power level in units of 0.1 dBm. |
||
ocmChannelUpdateLastChangeTime | 1.3.6.1.4.1.8708.2.33.2.3.1.1.5 |
Time when last measurement was done. |
||
ocmChannelOcmRefIfIndex | 1.3.6.1.4.1.8708.2.33.2.3.1.1.6 |
The SNMP-index of the OCM i/f object related to this object. |
||
ocmChannelReferencePowerLevel | 1.3.6.1.4.1.8708.2.33.2.3.1.1.7 |
The reference power level in units of 0.1 dBm. |
||
ocmChannelReferenceTime | 1.3.6.1.4.1.8708.2.33.2.3.1.1.8 |
Time where reference values were saved. |
||
ocmChannelSaveReference | 1.3.6.1.4.1.8708.2.33.2.3.1.1.9 |
Save current measurement as reference values |
||
lumentisOcmNotifications | 1.3.6.1.4.1.8708.2.33.2.4 |