Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
lumIfOtnMIBModule | 1.3.6.1.4.1.8708.1.1.50 | |||
lumIfOtnConfs | 1.3.6.1.4.1.8708.2.50.1 | |||
lumIfOtnGroups | 1.3.6.1.4.1.8708.2.50.1.1 | |||
lumIfOtnCompl | 1.3.6.1.4.1.8708.2.50.1.2 | |||
lumIfOtnMIBObjects | 1.3.6.1.4.1.8708.2.50.2 | |||
ifOtnGeneral | 1.3.6.1.4.1.8708.2.50.2.1 | |||
ifOtnGeneralConfigLastChangeTime | 1.3.6.1.4.1.8708.2.50.2.1.1 |
The time when the configuration of the MIB was last changed. |
||
ifOtnGeneralStateLastChangeTime | 1.3.6.1.4.1.8708.2.50.2.1.2 |
The time when the state and/or configuration of the MIB was last changed. |
||
ifOtnGeneralIfOtnOtuTableSize | 1.3.6.1.4.1.8708.2.50.2.1.3 |
Size of otn otu table. |
||
ifOtnGeneralIfOtnOtuConfigLastChangeTime | 1.3.6.1.4.1.8708.2.50.2.1.4 |
The time when the configuration of the table was last changed. |
||
ifOtnGeneralIfOtnOtuStateLastChangeTime | 1.3.6.1.4.1.8708.2.50.2.1.5 |
The time when the state and/or configuration of the table was last changed. |
||
ifOtnGeneralIfOtnOduTableSize | 1.3.6.1.4.1.8708.2.50.2.1.6 |
Size of otn odu table |
||
ifOtnGeneralIfOtnOduConfigLastChangeTime | 1.3.6.1.4.1.8708.2.50.2.1.7 |
The time when the configuration of the table was last changed. |
||
ifOtnGeneralIfOtnOduStateLastChangeTime | 1.3.6.1.4.1.8708.2.50.2.1.8 |
The time when the state and/or configuration of the MIB was last changed. |
||
ifOtnGeneralIfOtnOpuTableSize | 1.3.6.1.4.1.8708.2.50.2.1.9 |
Size of otn opu table |
||
ifOtnGeneralIfOtnOpuConfigLastChangeTime | 1.3.6.1.4.1.8708.2.50.2.1.10 |
The time when the configuration of the table was last changed. |
||
ifOtnGeneralIfOtnOpuStateLastChangeTime | 1.3.6.1.4.1.8708.2.50.2.1.11 |
The time when the state and/or configuration of the MIB was last changed. |
||
ifOtnGeneralIfOtnTpTableSize | 1.3.6.1.4.1.8708.2.50.2.1.12 |
Size of otn Tp table |
||
ifOtnGeneralIfOtnTpConfigLastChangeTime | 1.3.6.1.4.1.8708.2.50.2.1.13 |
The time when the configuration of the table was last changed. |
||
ifOtnGeneralIfOtnTpStateLastChangeTime | 1.3.6.1.4.1.8708.2.50.2.1.14 |
The time when the state and/or configuration of the MIB was last changed. |
||
ifOtnOtuList | 1.3.6.1.4.1.8708.2.50.2.2 | |||
ifOtnOtuTable | 1.3.6.1.4.1.8708.2.50.2.2.1 |
The optical channel transport unit (otu) group contains infor- mation and configuration for the Otu layer objects. |
||
1.3.6.1.4.1.8708.2.50.2.2.1.1 |
An entry in the ifOtn otu list. |
|||
ifOtnOtuIndex | 1.3.6.1.4.1.8708.2.50.2.2.1.1.1 |
An index assigned to each entry. |
||
ifOtnOtuName | 1.3.6.1.4.1.8708.2.50.2.2.1.1.2 |
The management name of the otn otu, for example otu:1:2:1-2, where the first number indicates subrack, the second slot number and the third/fourth are the physical port numbers. |
||
ifOtnOtuConnIfBasicIfIndex | 1.3.6.1.4.1.8708.2.50.2.2.1.1.3 |
An index that describes to which index in ifBasicIf table this object is related. |
||
ifOtnOtuTxSignalStatus | 1.3.6.1.4.1.8708.2.50.2.2.1.1.4 |
The state for outgoing (TX) signal of the interface. down - A major fault has occurred. degraded - The signal quality is impaired. up - The signal is OK. |
||
ifOtnOtuRxSignalStatus | 1.3.6.1.4.1.8708.2.50.2.2.1.1.5 |
The state for incoming (RX) signal of the interface. down - A major fault has occurred. degraded - The signal quality is impaired. up - The signal is OK. |
||
ifOtnOtuLossOfFrame | 1.3.6.1.4.1.8708.2.50.2.2.1.1.6 |
Loss of frame (LOF). Reference: 6.2.5.1 G.798 alarm: An OTU frame cannot be located. ok: An OTU frame can be located. |
||
ifOtnOtuRxAlarmIndicationSignal | 1.3.6.1.4.1.8708.2.50.2.2.1.1.7 |
Rx Alarm indication signal (AIS). Indicates if alarm indication signal (AIS) alarm exists or not in receiving direction. Reference: 16.4 G.709, 6.2, 6.3.3 G.798 alarm: An AIS in OTU signal is detected. ok: AIS inactive. |
||
ifOtnOtuLossOfMultiframe | 1.3.6.1.4.1.8708.2.50.2.2.1.1.8 |
Loss of multiframe (LOM). Indicates loss of multiframe. Reference: 6.2.5.2 G.798 A: Loss of multiframe is active. D: Loss of multiframe inactive. |
||
ifOtnOtuUpPortId | 1.3.6.1.4.1.8708.2.50.2.2.1.1.9 |
Internal port reference for traffic unit. |
||
ifOtnOduList | 1.3.6.1.4.1.8708.2.50.2.3 | |||
ifOtnOduTable | 1.3.6.1.4.1.8708.2.50.2.3.1 |
The optical channel data unit (odu) group contains information and configuration for the Odu layer objects. |
||
1.3.6.1.4.1.8708.2.50.2.3.1.1 |
An entry in the ifOtn odu list. |
|||
ifOtnOduIndex | 1.3.6.1.4.1.8708.2.50.2.3.1.1.1 |
An index assigned to each entry. |
||
ifOtnOduName | 1.3.6.1.4.1.8708.2.50.2.3.1.1.2 |
The management name of the otn odu, for example odu:1:2:1-2, where the first number indicates subrack, the second slot number and the third/fourth are the physical port numbers. |
||
ifOtnOduConnIfBasicIfIndex | 1.3.6.1.4.1.8708.2.50.2.3.1.1.3 |
An index that describes to which index in ifBasicIf table this object is related. |
||
ifOtnOduGcc1Terminated | 1.3.6.1.4.1.8708.2.50.2.3.1.1.4 |
Set if GCC1 should be terminated or not. true - GCC1 should be terminated false - GCC1 should not be terminated |
||
ifOtnOduGcc2Terminated | 1.3.6.1.4.1.8708.2.50.2.3.1.1.5 |
Set if GCC2 should be terminated or not. true - GCC2 should be terminated false - GCC2 should not be terminated |
||
ifOtnOduUsedTcms | 1.3.6.1.4.1.8708.2.50.2.3.1.1.6 |
This attribute indicates which ODU related TCMs that has been created. This is a bit-mask, where 0x00000000 means No TCM 0x00000001 means tcm1 0x00000010 means tcm2 ... 0x00100000 means tcm6 ... 0x00100010 means tcm2 + tcm6 ... 0x00111111 means all tcms i.e. tcm1 ..tcm6 |
||
ifOtnOduTxSignalStatus | 1.3.6.1.4.1.8708.2.50.2.3.1.1.7 |
The state for outgoing (TX) signal of the interface. This is reflecting the signalStatus of the OTN PM object and any terminated TCMs. down - A major fault has occurred. degraded - The signal quality is impaired. up - The signal is OK. |
||
ifOtnOduRxSignalStatus | 1.3.6.1.4.1.8708.2.50.2.3.1.1.8 |
The state for outgoing (RX) signal of the interface. This is reflecting the signalStatus of the OTN PM object and any terminated TCMs. down - A major fault has occurred. degraded - The signal quality is impaired. up - The signal is OK. |
||
ifOtnOduType | 1.3.6.1.4.1.8708.2.50.2.3.1.1.9 |
The odu type. |
||
ifOtnOduParentOduIndex | 1.3.6.1.4.1.8708.2.50.2.3.1.1.10 |
An index that describes to which index in ifOtnOduIf table this SubOdu object is related. |
||
ifOtnOpuList | 1.3.6.1.4.1.8708.2.50.2.4 | |||
ifOtnOpuTable | 1.3.6.1.4.1.8708.2.50.2.4.1 |
The optical channel payload unit (opu) group contains information and configuration for the Opu layer objects. |
||
1.3.6.1.4.1.8708.2.50.2.4.1.1 |
An entry in the ifOtn opu list. |
|||
ifOtnOpuIndex | 1.3.6.1.4.1.8708.2.50.2.4.1.1.1 |
An index assigned to each entry. |
||
ifOtnOpuName | 1.3.6.1.4.1.8708.2.50.2.4.1.1.2 |
The management name of the otn opu, for example opu:1:2:1-2, where the first number indicates subrack, the second slot number and the third/fourth are the physical port numbers. |
||
ifOtnOpuConnIfBasicIfIndex | 1.3.6.1.4.1.8708.2.50.2.4.1.1.3 |
An index that describes to which index in ifBasicIf table this object is related. |
||
ifOtnOpuTxSignalStatus | 1.3.6.1.4.1.8708.2.50.2.4.1.1.4 |
The state for outgoing (TX) signal of the interface. down - A major fault has occurred. degraded - The signal quality is impaired. up - The signal is OK. |
||
ifOtnOpuRxSignalStatus | 1.3.6.1.4.1.8708.2.50.2.4.1.1.5 |
The state for incoming (RX) signal of the interface. down - A major fault has occurred. degraded - The signal quality is impaired. up - The signal is OK. |
||
ifOtnOpuTxClientMaintenanceIndication | 1.3.6.1.4.1.8708.2.50.2.4.1.1.6 |
Tx generic alarm indication signal (generic AIS). Indicates if client maintenance signal (PN11) exists or not. alarm: A client maintenance signal is active. ok: Client maintenance signal inactive. Reference: 16.6.1 G.709/Y.1331 |
||
ifOtnOpuTxClientSignalFail | 1.3.6.1.4.1.8708.2.50.2.4.1.1.7 |
Tx Client signal fail (CSF). Indicates if insignal in remote end is failed or not. alarm: Remote end client is faulty. ok: Remote end client is OK. Reference: 17.1 G.709/Y.1331 |
||
ifOtnOpuRxPayloadMismatch | 1.3.6.1.4.1.8708.2.50.2.4.1.1.8 |
Rx Payload mismatch (PLM). Monitored overhead: OPUk-PLM Direction: Received from the associated physical interface and, unless the ODUk is terminated, the PLM is sent towards the board-internal G.805 Matrix. Reference 6.2.4.1 G.798 Values: alarm: The OPUk-PLM overhead is declared as active if the incoming payload type is not equal to the expected payload type(s). ok: The OPUk-PLM overhead is declared as inactive if the incoming payload type is equal to the expected payload type(s). |
||
ifOtnOpuTxPayloadMismatch | 1.3.6.1.4.1.8708.2.50.2.4.1.1.9 |
Tx Payload mismatch (PLM). Monitored overhead: OPUk-PLM Direction: Received from the board-internal G.805 Matrix and, if applicable, sent towards the physical interface. Reference 6.2.4.1 G.798 Values: alarm: The OPUk-PLM overhead is declared as active if the incoming payload type is not equal to the expected payload type(s). ok: The OPUk-PLM overhead is declared as inactive if the incoming payload type is equal to the expected payload type(s) |
||
ifOtnOpuLossOfOpuMultiFrameIdentifier | 1.3.6.1.4.1.8708.2.50.2.4.1.1.10 |
Rx Loss of OPU Multi-frame identifier (LOOMFI). Monitored overhead: OPU4 Multi-Frame Identifier Direction: OPU4 Rx. If the expected 80-frame identifier goes out of expected sequence for a period of > 3 ms, LOOMFI is declared. Reference: 14.3.10.2 G.798 Values: alarm: The OPU Multi-frame identifier is lost. ok: The OPU Multi-frame identifier is present. |
||
ifOtnOpuRxClientMaintenanceIndication | 1.3.6.1.4.1.8708.2.50.2.4.1.1.11 |
Rx generic alarm indication signal (generic AIS). Indicates if client maintenance signal (PN11) exists or not. alarm: A client maintenance signal is active. ok: Client maintenance signal inactive. Reference: 16.6.1 G.709/Y.1331 |
||
ifOtnOpuConnOduIndex | 1.3.6.1.4.1.8708.2.50.2.4.1.1.12 |
An index that describes to which index in Odu table this object is related. |
||
ifOtnTpList | 1.3.6.1.4.1.8708.2.50.2.5 | |||
ifOtnTpTable | 1.3.6.1.4.1.8708.2.50.2.5.1 |
The optical channel payload unit (tp) group contains information and configuration for the Tp layer objects. |
||
1.3.6.1.4.1.8708.2.50.2.5.1.1 |
An entry in the ifOtn tp list. |
|||
ifOtnTpIndex | 1.3.6.1.4.1.8708.2.50.2.5.1.1.1 |
An index assigned to each entry. |
||
ifOtnTpName | 1.3.6.1.4.1.8708.2.50.2.5.1.1.2 |
The management name of the otn tp, for example tp:1:2:1, where the first number indicates subrack, the second slot number and the third is the tributary port number. |
||
ifOtnTpConnIfBasicIfIndex | 1.3.6.1.4.1.8708.2.50.2.5.1.1.3 |
An index that describes to which index in the ifBasicIf table this object is related. |
||
ifOtnTpUsedTribSlots | 1.3.6.1.4.1.8708.2.50.2.5.1.1.4 |
The number of tributary slots occupied by this tributary port |
||
ifOtnTpTribPortId | 1.3.6.1.4.1.8708.2.50.2.5.1.1.5 |
Tributary port id. |
||
ifOtnTpRxMultiplexStructureIdentifierMismatch | 1.3.6.1.4.1.8708.2.50.2.5.1.1.6 |
Rx Multiplex structure identifier mismatch (MSIM). Indicates received MSI is not equal to expected MSI. alarm: The MSIM shall be declared for the ODU tributary port if the received MSI is not equal to the expected MSI. ok: MSIM shall be cleared if the received MSI is equal to the expected MSI. reference 19.4.1 G709, 6.2.9.1 G.798 |
||
ifOtnTpTxSignalStatus | 1.3.6.1.4.1.8708.2.50.2.5.1.1.7 |
The state for outgoing (TX) signal of the interface. down - A major fault has occurred. degraded - The signal quality is impaired. up - The signal is OK. |
||
ifOtnTpRxSignalStatus | 1.3.6.1.4.1.8708.2.50.2.5.1.1.8 |
The state for incoming (RX) signal of the interface. down - A major fault has occurred. degraded - The signal quality is impaired. up - The signal is OK. |
||
ifOtnTpXcRefOduIndex | 1.3.6.1.4.1.8708.2.50.2.5.1.1.9 |
An index that describes to which index in ifOtnOduIf table this TP object is contained in. |
||
ifOtnTpTribSlotMask | 1.3.6.1.4.1.8708.2.50.2.5.1.1.10 |
Tributary slot mask string Format: <bit-mask> |
||
ifOtnTpTribSlotView | 1.3.6.1.4.1.8708.2.50.2.5.1.1.11 |
Tributary slots |