LUM-IFBASIC-MIB: View SNMP OID List / Download MIB

VENDOR: LUMENTIS AB


 Home MIB: LUM-IFBASIC-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 lumIfBasicMIBModule 1.3.6.1.4.1.8708.1.1.46
   lumIfBasicConfs 1.3.6.1.4.1.8708.2.46.1
       lumIfBasicGroups 1.3.6.1.4.1.8708.2.46.1.1
       lumIfBasicCompl 1.3.6.1.4.1.8708.2.46.1.2
   lumIfBasicMIBObjects 1.3.6.1.4.1.8708.2.46.2
       ifBasicGeneral 1.3.6.1.4.1.8708.2.46.2.1
           ifBasicGeneralConfigLastChangeTime 1.3.6.1.4.1.8708.2.46.2.1.1
The time when the configuration of the MIB was last changed.
           ifBasicGeneralStateLastChangeTime 1.3.6.1.4.1.8708.2.46.2.1.2
The time when the state of the MIB was last changed.
           ifBasicGeneralIfBasicIfTableSize 1.3.6.1.4.1.8708.2.46.2.1.3
Size of if table
           ifBasicGeneralIfBasicIfConfigLastChangeTime 1.3.6.1.4.1.8708.2.46.2.1.4
The time when the configuration of the table was last changed.
           ifBasicGeneralIfBasicIfStateLastChangeTime 1.3.6.1.4.1.8708.2.46.2.1.5
The time when the state and/or configuration of the table was last changed.
           ifBasicGeneralIfBasicAdminTableSize 1.3.6.1.4.1.8708.2.46.2.1.6
Size of admin table
           ifBasicGeneralIfBasicAdminConfigLastChangeTime 1.3.6.1.4.1.8708.2.46.2.1.7
The time when the configuration of the table was last changed.
           ifBasicGeneralIfBasicAdminStateLastChangeTime 1.3.6.1.4.1.8708.2.46.2.1.8
The time when the state and/or configuration of the table was last changed.
           ifBasicGeneralIfBasicSignalTableSize 1.3.6.1.4.1.8708.2.46.2.1.9
Size of signal table
           ifBasicGeneralIfBasicSignalConfigLastChangeTime 1.3.6.1.4.1.8708.2.46.2.1.10
The time when the configuration of the table was last changed.
           ifBasicGeneralIfBasicSignalStateLastChangeTime 1.3.6.1.4.1.8708.2.46.2.1.11
The time when the state and/or configuration of the table was last changed.
       ifBasicIfList 1.3.6.1.4.1.8708.2.46.2.2
           ifBasicIfTable 1.3.6.1.4.1.8708.2.46.2.2.1
The if basic if interface list.
               ifBasicIfEntry 1.3.6.1.4.1.8708.2.46.2.2.1.1
An entry in the ifBasic if list.
                   ifBasicIfIndex 1.3.6.1.4.1.8708.2.46.2.2.1.1.1
An index assigned to each entry.
                   ifBasicIfName 1.3.6.1.4.1.8708.2.46.2.2.1.1.2
The management name of the interface, for example client:1:2:1-2, where the first number indicates subrack, the second slot number and the third/fourth are the physical port numbers.
                   ifBasicIfTxSignalStatus 1.3.6.1.4.1.8708.2.46.2.2.1.1.3
The state for outgoing (TX) signal of the interface. down - A major fault has occurred. degraded - The signal quality is impaired. up - The signal is OK.
                   ifBasicIfRxSignalStatus 1.3.6.1.4.1.8708.2.46.2.2.1.1.4
The state for incoming (RX) signal of the interface. down - A major fault has occurred. degraded - The signal quality is impaired. up - The signal is OK.
                   ifBasicIfUpId 1.3.6.1.4.1.8708.2.46.2.2.1.1.5
Identity in the UP for the interface. The upId is used internally between CU and TU to define a certain interface in the TU.
                   ifBasicIfAid 1.3.6.1.4.1.8708.2.46.2.2.1.1.6
The access identifier (AID) of the interface. The format is according to GR-833.
                   ifBasicIfPhysicalLocation 1.3.6.1.4.1.8708.2.46.2.2.1.1.7
The physical location of the if. The format is according to GR-833.
       ifBasicAdminList 1.3.6.1.4.1.8708.2.46.2.3
           ifBasicAdminTable 1.3.6.1.4.1.8708.2.46.2.3.1
The if basic admin interface list.
               ifBasicAdminEntry 1.3.6.1.4.1.8708.2.46.2.3.1.1
An entry in the ifBasic admin list.
                   ifBasicAdminIndex 1.3.6.1.4.1.8708.2.46.2.3.1.1.1
An index assigned to each entry.
                   ifBasicAdminName 1.3.6.1.4.1.8708.2.46.2.3.1.1.2
The management name of the interface, for example admin:1:2:1-2, where the first number indicates subrack, the second slot number and the third/fourth are the physical port numbers.
                   ifBasicAdminDescr 1.3.6.1.4.1.8708.2.46.2.3.1.1.3
User configurable label.
                   ifBasicAdminSubrack 1.3.6.1.4.1.8708.2.46.2.3.1.1.4
The subrack of the physical port that this interface is bound to.
                   ifBasicAdminSlot 1.3.6.1.4.1.8708.2.46.2.3.1.1.5
The slot of the physical port that this interface is bound to.
                   ifBasicAdminTxPort 1.3.6.1.4.1.8708.2.46.2.3.1.1.6
The transmitting physical port that this interface is bound to.
                   ifBasicAdminRxPort 1.3.6.1.4.1.8708.2.46.2.3.1.1.7
The receiving physical port that this interface is bound to.
                   ifBasicAdminAdminStatus 1.3.6.1.4.1.8708.2.46.2.3.1.1.8
The administrative state of the ifBasic interface. down - The interface is de-activated. service - The interface is activated but alarms are suppressed. Intended for use during service or re-configuration. When service is concluded adminStatus should be set to up again. Note that there is no difference between up and service, if no alarms can be raised from this object. up - The interface will be activated when available. Alarms are not suppressed.
                   ifBasicAdminOperStatus 1.3.6.1.4.1.8708.2.46.2.3.1.1.9
The operational state for the interface. notPresent - The interface is not available. down - The interface is de-activated or there are faults preventing its transition to the up state. up - The interface is active.
                   ifBasicAdminAutoAlarmEnableStatus 1.3.6.1.4.1.8708.2.46.2.3.1.1.10
The state of auto alarm enable for the interface. suppressTrxAndSignal - Both signal alarms and trx alarms are suppressed suppressSignal - Only signal alarms are suppressed suppressNone - Neither trx nor signal alarms are suppressed
                   ifBasicAdminAutoAlarmEnableReset 1.3.6.1.4.1.8708.2.46.2.3.1.1.11
When the attribute is set to reset the auto-alarm enable function is re-initialised. Then the attribute is set to normal again automatically. reset - Re-initialises the auto-alarm enable function normal - The auto-alarm enable function is in normal state
                   ifBasicAdminInterfaceStatus 1.3.6.1.4.1.8708.2.46.2.3.1.1.12
The status of the traffic interface. outOfService - No PM and no alarms. autoInService - No PM and no alarms. Changes to inService when OK. inService - Reports PM and alarms. maintenance - Maintenance mode.
                   ifBasicAdminIfNo 1.3.6.1.4.1.8708.2.46.2.3.1.1.13
The physical interface number of the actual multi-connector port.
                   ifBasicAdminIfType 1.3.6.1.4.1.8708.2.46.2.3.1.1.14
Type of interface (Individual or bundled).
                   ifBasicAdminNotAvailableForUse 1.3.6.1.4.1.8708.2.46.2.3.1.1.15
Is the interface not available for use. The interface may be created in order to show some physical properties but may otherwise be unavailable for service depending on setup and available resources.
       ifBasicSignalList 1.3.6.1.4.1.8708.2.46.2.4
           ifBasicSignalTable 1.3.6.1.4.1.8708.2.46.2.4.1
The if basic signal interface list.
               ifBasicSignalEntry 1.3.6.1.4.1.8708.2.46.2.4.1.1
An entry in the ifBasic signal list.
                   ifBasicSignalIndex 1.3.6.1.4.1.8708.2.46.2.4.1.1.1
An index assigned to each entry.
                   ifBasicSignalName 1.3.6.1.4.1.8708.2.46.2.4.1.1.2
The management name of the interface, for example signal:1:2:1-2, where the first number indicates subrack, the second slot number and the third/fourth are the physical port numbers.
                   ifBasicSignalSignalStructure 1.3.6.1.4.1.8708.2.46.2.4.1.1.3
The signal structure used. Bitfield 64 bit wide. For internal use. Bit 0 tells if mib ifBasicPhysicalTrx is loaded, bit 1 ifBasicOpticalTranssection, etc according to list below. Add new items last. ifPhysicalTrx ifOpticalTranssection ifOpticalChannel ifOpticalDigitalSignalRate ifEthPhysical ifEthMac ifOtnOdu ifOtnOtu ifOtnOpu ifOtnMonSm ifOtnMonPm ifOtnMonTcm ifOtnMonTrace ifSdhRs ifSdhMs ifSonetSection ifSonetLine ifPerfFec ifPerfAdmin ifPerfG826 ifPerfL2Error ifPerfL1 ifPerfL0 ifOpticalFec ifFcPhysical ifOtnTp ifOpticalTransportLaneCarrier ifOpticalTransportLaneCarrierGroup ifPerfL2Stat ifIwdmRs ifIwdmMS ifAmplifierAmplifier ifAmplifierModule ifAmplifierRaman ifAmplifierEdfa ifIwdmPath ifFhCpri ifFhObsai ifPhysicalCage ifEthRsFec ifPerfDelay ifOtdr
                   ifBasicSignalSignalFormat 1.3.6.1.4.1.8708.2.46.2.4.1.1.4
The signal format.
                   ifBasicSignalFarEndLoopbackTerminatingLayer 1.3.6.1.4.1.8708.2.46.2.4.1.1.5
The layer where the far end loopback (a.k.a. terminal loopback for a client interface and facility loopback for a line interface) is done. This is coded in a bitmask
                   ifBasicSignalFarEndLoopback 1.3.6.1.4.1.8708.2.46.2.4.1.1.6
The far end loopback (a.k.a. terminal loopback for a client interface and facility loopback for a line interface) setting. disabled - Far end loopback is not set. This is the default setting. enabled - Far end loopback is set.
                   ifBasicSignalFarEndLoopbackTimeout 1.3.6.1.4.1.8708.2.46.2.4.1.1.7
Timeout for far end loopback (a.k.a. terminal loopback for a client interface and facility loopback for a line interfac) to make sure connection to node is not lost if ppp link is broken. The unit is minutes. The value 0 is used in SNMP to indicate that the setting will last forever. Note! This attribute is not saved in backup, meaning the loopback will be set to disabled when rebooting CU.
                   ifBasicSignalNearEndLoopbackTerminatingLayer 1.3.6.1.4.1.8708.2.46.2.4.1.1.8
The layer where the near end loopback (a.k.a. terminal loopback for a line interface and facility loopback for a client interface) is done. This is coded in a bitmask.
                   ifBasicSignalNearEndLoopback 1.3.6.1.4.1.8708.2.46.2.4.1.1.9
The near end loopback (a.k.a. terminal loopback for a line interface and facility loopback for a client interface) setting. disabled - Near end loopback is not set. This is the default setting. enabled - Near end loopback is set.
                   ifBasicSignalNearEndLoopbackTimeout 1.3.6.1.4.1.8708.2.46.2.4.1.1.10
Timeout for near end loopback (a.k.a. terminal loopback for a line interface and facility loopback for a client interface) to make sure connection to node is not lost if ppp link is broken. The unit is minutes. The value 0 is used in SNMP to indicate that the setting will last forever. Note! This attribute is not saved in backup, meaning the loopback will be set to disabled when rebooting CU.
                   ifBasicSignalFarEndLoopbackEnabled 1.3.6.1.4.1.8708.2.46.2.4.1.1.11
Far end end loopback (a.k.a. terminal loopback for a client interface and facility loopback for a line interface) is enabled. alarm: Far end loopback is enabled. ok: Far end loopback is disabled.
                   ifBasicSignalNearEndLoopbackEnabled 1.3.6.1.4.1.8708.2.46.2.4.1.1.12
Near end end loopback (a.k.a. terminal loopback for a line interface and facility loopback for a client interface) is enabled. alarm: Near end loopback is enabled. ok: Near end loopback is disabled.
                   ifBasicSignalOpticalLayerMapping 1.3.6.1.4.1.8708.2.46.2.4.1.1.13
The optical layer mapping.
                   ifBasicSignalConfigurationMismatch 1.3.6.1.4.1.8708.2.46.2.4.1.1.14
The inserted transceiver does not support the configuration of the optical layer mapping. alarm: A transceiver with other supported optical layer mapping than the requested mapping is inserted. ok: The transceiver with the non-requested optical layer mapping is removed, or the object is reconfigured.
                   ifBasicSignalActualOpticalLayerMapping 1.3.6.1.4.1.8708.2.46.2.4.1.1.15
The actual optical layer mapping.
                   ifBasicSignalSpeed 1.3.6.1.4.1.8708.2.46.2.4.1.1.16
The expected signal bit rate in units of 10,000 bits (0.01 Mb) per second.
                   ifBasicSignalDirection 1.3.6.1.4.1.8708.2.46.2.4.1.1.17
The direction in which this object is referred to. rx - In bound direction. (1) tx - out bound direction. (2) biDir - the interface has one connector used for both rx and tx. (3) txRx - the interface has two connectors one for tx and one for rx. (4) Not Available - the direction is not available.
                   ifBasicSignalFormatConfigurable 1.3.6.1.4.1.8708.2.46.2.4.1.1.18
This atttribute indicates if the interface is format configurable or not true - The interface is format configurable false - The interface is not format configurable
                   ifBasicSignalFormatConfigurationSharedWithInterface 1.3.6.1.4.1.8708.2.46.2.4.1.1.19
This attribute specifies whether this object instances shares the format configuration with another object instance. value == 0: it is not shared value != 0: it is shared with the interface object with index = value in IfBasicIfEntry If it is shared, it means that updating the format (and optionally speed) will affect the configuration of the other object instance
                   ifBasicSignalPhysicalLayerMapping 1.3.6.1.4.1.8708.2.46.2.4.1.1.20
The expected physical layer mapping.
                   ifBasicSignalFacilityLoopback 1.3.6.1.4.1.8708.2.46.2.4.1.1.21
The facility loopback setting. Rx is looped to Tx. The purpose of facility loopback is to test the line interface termination. disabled - Facility loopback is not set. This is the default setting. enabled - Facility loopback is set.
                   ifBasicSignalFacilityLoopbackTimeout 1.3.6.1.4.1.8708.2.46.2.4.1.1.22
Timeout for facility loopback to make sure connection to node is not lost if ppp link is broken. The unit is minutes. Note! This attribute is not saved in backup, meaning the loopback will be set to disabled when rebooting CU.
                   ifBasicSignalFacilityLoopbackEnabled 1.3.6.1.4.1.8708.2.46.2.4.1.1.23
Facility loopback is enabled. alarm: Facility loopback is enabled. ok: Facility loopback is disabled.
                   ifBasicSignalTerminalLoopback 1.3.6.1.4.1.8708.2.46.2.4.1.1.24
The terminal loopback setting. Tx is looped to Rx. The purpose of a terminal loopback is to test the path through the equipment (a cross-connect, mux/demux stage, or similar) and execute the loop close to the outgoing interface. disabled - Terminal loopback is not set. This is the default setting. enabled - Terminal loopback is set.
                   ifBasicSignalTerminalLoopbackTimeout 1.3.6.1.4.1.8708.2.46.2.4.1.1.25
Timeout for terminal loopback to make sure connection to node is not lost if ppp link is broken. The unit is minutes. Note! This attribute is not saved in backup, meaning the loopback will be set to disabled when rebooting CU.
                   ifBasicSignalTerminalLoopbackEnabled 1.3.6.1.4.1.8708.2.46.2.4.1.1.26
Terminal loopback is enabled. alarm: Terminal loopback is enabled. ok: Terminal loopback is disabled.
                   ifBasicSignalConnectorType 1.3.6.1.4.1.8708.2.46.2.4.1.1.27
The connector type.