LSI-megaRAID-SAS-IR-MIB: View SNMP OID List / Download MIB
VENDOR: LSI LOGIC
Home | MIB: LSI-megaRAID-SAS-IR-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
lsi | 1.3.6.1.4.1.3582 | |||
lsiStorageComponents | 1.3.6.1.4.1.3582.5 | |||
lsiRAIDServer | 1.3.6.1.4.1.3582.5.1 | |||
hostName | 1.3.6.1.4.1.3582.5.1.1 | displaystring | read-only |
Name of the host system. |
hostOSInfo | 1.3.6.1.4.1.3582.5.1.2 | displaystring | read-only |
Operating System description where SNMP agent is running. |
versionInfo | 1.3.6.1.4.1.3582.5.1.3 | |||
mibVersion | 1.3.6.1.4.1.3582.5.1.3.1 | displaystring | read-only |
The MIB version no. (xx.yy.zz) |
agentModuleName | 1.3.6.1.4.1.3582.5.1.3.2 | displaystring | read-only |
The agent module name |
agentModuleVersion | 1.3.6.1.4.1.3582.5.1.3.3 | displaystring | read-only |
The module version in xx.yy format. Where xx is the major version number and yy is the minor version number(without build information). |
releaseDate | 1.3.6.1.4.1.3582.5.1.3.4 | displaystring | read-only |
Module Release Date (DD/MM/YYYY) |
megaRAID_SAS_IR | 1.3.6.1.4.1.3582.5.1.4 | |||
adapter | 1.3.6.1.4.1.3582.5.1.4.1 | |||
adapterDetails | 1.3.6.1.4.1.3582.5.1.4.1.1 | |||
adpNumber | 1.3.6.1.4.1.3582.5.1.4.1.1.1 | gauge | read-only |
The total no of SAS adapters present. |
adapterPropertiesTable | 1.3.6.1.4.1.3582.5.1.4.1.1.2 | no-access |
A List of adapter Entries containing Information/Properties about the adapters. |
|
1.3.6.1.4.1.3582.5.1.4.1.1.2.1 | no-access |
An Entry in the adapter table. |
||
adapterID | 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.1 | integer | read-only |
AdapterID for this Adapter.(Unique) |
rebuildRate | 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.2 | integer | read-only |
Rebuild rate on this Adapter. |
reconstructionRate | 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.3 | integer | read-only |
Reconstruction rate on this Adapter. |
alarmState | 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.4 | integer | read-only |
Alarm is enabled(1) or disabled(0) on this adapter. |
cacheFlushInterval | 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.5 | integer | read-only |
Cache flush interval in seconds for this adapter. |
clusterState | 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.6 | integer | read-only |
Cluster is enabled(1) or disabled(0) on this adapter. |
predFailPollInterval | 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.7 | integer | read-only |
Number of seconds between predictive fail polls on this adapter. |
intThrottleCount | 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.8 | integer | read-only |
Interrupt throttle active count on this adapter. |
intThrottleTimeUs | 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.9 | integer | read-only |
Interrupt throttle completion hold time on this adapter. |
patrolReadRate | 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.10 | integer | read-only |
Patrol Read Rate for this adapter. |
bgiRate | 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.11 | integer | read-only |
Background initialization rate for this adapter. |
ccRate | 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.12 | integer | read-only |
Consistency Check rate on this Adapter. |
spinupDelay | 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.13 | integer | read-only |
Number of seconds to delay among spinup groups for this adapter. |
spinupDriveCount | 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.14 | integer | read-only |
Maximum number of drives to spin up at one time for this adapter. |
coercionMode | 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.15 | integer | read-only |
Drive capacity coercion mode. 0->None; 1->128MB; 2->1GB; 3->Adaptive Coercion. |
disableAutoRebuild | 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.16 | integer | read-only |
auto-rebuild and hot-spare commissioning status. 1->Disable , 0->Enable |
disableBatteryWarning | 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.17 | integer | read-only |
disable/enable warnings for missing battery or missing HW status. 1->Disable , 0->Enable |
multipathSupport | 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.18 | integer | read-only |
Multipath is supported or not supported on this adapter.Values: not supported(0),supported(1) |
ssdSMARTerEnabled | 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.19 | integer | read-only |
Copyback to SSD on SMART error. Values Enabled(0),Disabled(1) |
sasAddr | 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.20 | displaystring | read-only |
This field gives the controller SAS address |
auxilaryPowerPresent | 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.21 | displaystring | read-only |
Presence of Auxilary Power |
ddLifeCurveStatus | 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.22 | displaystring | read-only |
Check for throttling |
ddSSDLifeLeft | 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.23 | displaystring | read-only |
Percentage of SSD life left |
dDStatus | 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.24 | displaystring | read-only |
Overall DD status |
adapterInfoTable | 1.3.6.1.4.1.3582.5.1.4.1.1.3 | no-access |
A List of adapter Entries containing Information/Properties about the adapters. |
|
1.3.6.1.4.1.3582.5.1.4.1.1.3.1 | no-access |
An Entry in the adapterInfo table. |
||
infAdpID | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.1 | integer | read-only |
AdapterID for this Adapter.(Unique) |
vendorId | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.2 | integer | read-only |
PCI Vendor ID for this Adapter. |
devId | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.3 | integer | read-only |
PCI Device ID for this Adapter. |
subVendorID | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.4 | integer | read-only |
PCI Sub-Vendor ID for this adapter. |
subDevID | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.5 | integer | read-only |
PCI Sub-Device ID for this adapter. |
hostInterface | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.6 | integer | read-only |
Host interface information for this adapter. Values are as follows: N/A(0), PCIX(1), PCIE(2), iSCSI(3), SAS_3G(4) |
hostInterfacePortCnt | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.7 | integer | read-only |
Port Count on this adapter. |
hostInterfacePortAddr | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.8 | displaystring | read-only |
Port address comma delimited |
devInterface | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.9 | displaystring | read-only |
Multiple device interface support values separated by space. |
devInterfacePortCnt | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.10 | integer | read-only |
Device Port Count on this adapter. |
devInterfacePortAddr | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.11 | displaystring | read-only |
Device Port address comma delimited |
productName | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.12 | displaystring | read-only |
Product name e.g. SAS2008 B1. |
serialNo | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.13 | displaystring | read-only |
Controller serial number |
firmwareVersion | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.14 | displaystring | read-only |
Firmware version Format->(Firmware Package Version:Version:Date:Time) |
driverVersion | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.15 | displaystring | read-only |
Driver version Format->(Driver Name:Version) |
nvramSize | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.16 | integer | read-only |
NVRAM size in KB for this adapter.A value -1 for invalid or undefined size. |
memorySize | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.17 | integer | read-only |
Memory size in MB for this adapter.A value -1 for invalid or undefined size. |
flashSize | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.18 | integer | read-only |
Flash size in MB for this adapter.A value -1 for invalid or undefined size. |
vdPresentCount | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.19 | integer | read-only |
Virtual devices present in this adapter. |
vdDegradedCount | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.20 | integer | read-only |
Number of virtual devices in this adapter that are critical |
vdOfflineCount | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.21 | integer | read-only |
Number of virtual devices in this adapter that are offline |
pdPresentCount | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.22 | integer | read-only |
Physical devices present in this adapter. |
pdDiskPresentCount | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.23 | integer | read-only |
Physical disk devices present in this adapter. |
pdDiskPredFailureCount | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.24 | integer | read-only |
Number of disk devices in this adapter that are critical |
pdDiskFailedCount | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.25 | integer | read-only |
Number of disk devices in this adapter that are failed |
clusterStatus | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.26 | integer | read-only |
Cluster state on this adapter. Values: ACTIVE(1), INACTIVE(0) |
devInterfaceType | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.27 | integer | read-only |
Type of the interface of the IR adapter. Values: GEN1(0), GEN2(1) |
adapterSupportInfoTable | 1.3.6.1.4.1.3582.5.1.4.1.1.4 | no-access |
A List of Entries containing Properties supported by the Controller. |
|
1.3.6.1.4.1.3582.5.1.4.1.1.4.1 | no-access |
An Entry in the adapter table. |
||
suAdpID | 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.1 | integer | read-only |
AdapterID for this Adapter.(Unique) |
supportMaxArms | 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.2 | integer | read-only |
Maximum arms per Logical Drive supported for this Adapter. |
supportMaxSpans | 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.3 | integer | read-only |
Maximum spans per Logical Drive supported for this Adapter. |
supportMaxArrays | 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.4 | integer | read-only |
Maximum number arrays supported this Adapter. |
supportMaxLDs | 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.5 | integer | read-only |
Maximum number of Logical Drive's supported for this Adapter. |
supportHardwarePresent | 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.6 | displaystring | read-only |
Supported Hardware on this adapter. bbu(1),alarm(2),nvram(3),uart(4). For multiple hardware support a comma delimited list will appear. |
supportMaxConcurrentCmds | 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.7 | integer | read-only |
The maximum parallel commands supported on this Adapter. |
supportMaxSGECount | 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.8 | integer | read-only |
The maximum Scatter Gather Element count allowed on this Adapter. |
supportMaxRequestSize | 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.9 | integer | read-only |
The maximum data transfer size in sectors, on this Adapter. |
supportClusterPermitted | 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.10 | integer | read-only |
Clustering support on this Adapter. Values: FALSE(0), TRUE(1) |
supportMinStripeSize | 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.11 | integer | read-only |
Minimum stripe size supported. 0(512),1(1K),2(2K),3(4K),4(8K),5(16K),6(32),7(64K),8(128K) ... 11(1MB) etc |
supportMaxStripeSize | 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.12 | integer | read-only |
Maximum stripe size supported. 0(512),1(1K),2(2K),3(4K),4(8K),5(16K),6(32),7(64K),8(128K) ... 11(1MB) etc |
supportSupportsSAS | 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.13 | integer | read-only |
SAS physical drive support.Values: notSupported(0), supported(1) |
supportSupportsSATA | 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.14 | integer | read-only |
SATA physical drive support.Values: notSupported(0), supported(1) |
supportAllowMixInEnclosure | 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.15 | integer | read-only |
Mix InEnclosure support.Values: notSupported(0), supported(1) |
supportAllowMixInVD | 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.16 | integer | read-only |
MixInVD support.Values: notSupported(0), supported(1) |
supportAllowSataInCluster | 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.17 | integer | read-only |
SataInCluster support. Values: notSupported(0), supported(1) |
allowSSDMixInLD | 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.18 | integer | read-only |
allow SAS/SATA SSD mix within an LD. allow(1), not allow(0) |
allowMixSSDHDDInLD | 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.19 | integer | read-only |
allow SSD/HDD mix within an LD.allow(1), not allow(0) |
adpOperationsSupportInfoTable | 1.3.6.1.4.1.3582.5.1.4.1.1.5 | no-access |
A List of Entries containing operations supported by the Controller. |
|
1.3.6.1.4.1.3582.5.1.4.1.1.5.1 | no-access |
An Entry in the adapter table. |
||
opAdpID | 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.1 | integer | read-only |
AdapterID for this Adapter.(Unique) |
rbldRate | 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.2 | integer | read-only |
Rebuilding rate change support for this Adapter. Values: False(0), True(1) |
suCCRate | 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.3 | integer | read-only |
Consistency Check rate change support for this Adapter. Values: False(0), True(1) |
suBgiRate | 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.4 | integer | read-only |
Background initialization rate change support for this adapter. Values: False(0), True(1) |
reconRate | 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.5 | integer | read-only |
Reconstruction rate change support for this adapter. Values: False(0), True(1) |
patrolRate | 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.6 | integer | read-only |
Patrol read rate change support for this adapter. Values: False(0), True(1) |
alarmControl | 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.7 | integer | read-only |
Alarm control support for this adapter. Values: False(0), True(1) |
clusterSupported | 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.8 | integer | read-only |
Cluster support for this adapter. Values: False(0), True(1) |
bbu | 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.9 | integer | read-only |
BBU support for this adapter. Values: False(0), True(1) |
spanningAllowed | 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.10 | integer | read-only |
Spanning support for this adapter. Values: False(0), True(1) |
dedicatedHotSpares | 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.11 | integer | read-only |
Dedicated HotSpares for this adapter. Values: False(0), True(1) |
revertibleHotSpares | 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.12 | integer | read-only |
Revertible HotSpares support for this adapter. Values: False(0), True(1) |
foreignConfigImport | 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.13 | integer | read-only |
Support foreign config import on this adapter. Values: False(0), True(1) |
selfDiagnostic | 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.14 | integer | read-only |
Controller supports self diagnostic. Values: False(0), True(1) |
allowMixedRedundancyOnArray | 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.15 | integer | read-only |
Allow different Virtual Disk on the same array to have different redundancy levels Values: False(0), True(1) |
globalHotSpares | 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.16 | integer | read-only |
Global hot spares are supported. Values: False(0), True(1) |
oceWithNoDriveAddition | 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.17 | integer | read-only |
Online Capacity Expansion supported. Values: False(0), True(1) |
driveOperationSupportTable | 1.3.6.1.4.1.3582.5.1.4.1.1.6 | no-access |
A List of operations supported by Physical Drive. |
|
1.3.6.1.4.1.3582.5.1.4.1.1.6.1 | no-access |
An Entry in the driveOperationSupport table. |
||
drvAdpID | 1.3.6.1.4.1.3582.5.1.4.1.1.6.1.1 | integer | read-only |
Unique adapter ID |
forceOnline | 1.3.6.1.4.1.3582.5.1.4.1.1.6.1.2 | integer | read-only |
Physical Drive force Online operation support Values: notSupported(0), supported(1) |
forceOffline | 1.3.6.1.4.1.3582.5.1.4.1.1.6.1.3 | integer | read-only |
Physical Drive force Offline operation support Values: notSupported(0), supported(1) |
forceRebuild | 1.3.6.1.4.1.3582.5.1.4.1.1.6.1.4 | integer | read-only |
Physical Drive force Rebuild operation support Values: notSupported(0), supported(1) |
vdOperationSupportTable | 1.3.6.1.4.1.3582.5.1.4.1.1.7 | no-access |
A List operations supported by Virtual Drive |
|
1.3.6.1.4.1.3582.5.1.4.1.1.7.1 | no-access |
An Entry in the vdOperationSupport Table. |
||
vdOpAdpID | 1.3.6.1.4.1.3582.5.1.4.1.1.7.1.1 | integer | read-only |
Unique adapter ID |
readPolicy | 1.3.6.1.4.1.3582.5.1.4.1.1.7.1.2 | integer | read-only |
Read policy support. Values: False(0), True(1) |
writePolicy | 1.3.6.1.4.1.3582.5.1.4.1.1.7.1.3 | integer | read-only |
Write policy support. Values: False(0), True(1) |
ioPolicy | 1.3.6.1.4.1.3582.5.1.4.1.1.7.1.4 | integer | read-only |
IO policy support. Values: False(0), True(1) |
accessPolicy | 1.3.6.1.4.1.3582.5.1.4.1.1.7.1.5 | integer | read-only |
Access policy support. Values: False(0), True(1) |
diskCachePolicy | 1.3.6.1.4.1.3582.5.1.4.1.1.7.1.6 | integer | read-only |
Disk Cache Policy support. Values: False(0), True(1) |
bbuInfo | 1.3.6.1.4.1.3582.5.1.4.1.2 | |||
bbuNumber | 1.3.6.1.4.1.3582.5.1.4.1.2.1 | gauge | read-only |
The present number of rows in the bbuTable. |
bbuTable | 1.3.6.1.4.1.3582.5.1.4.1.2.2 | no-access |
A List of bbu Entries containing Information/Properties about the BBU. |
|
1.3.6.1.4.1.3582.5.1.4.1.2.2.1 | no-access |
An Entry in the BBU table. |
||
bbuID | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.1 | integer | read-only |
BBUID for this BBU.(Unique) |
batteryType | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.2 | integer | read-only |
BBU Type: Values: n/a(0), ibbu(1), bbu(2), zcr_legacy(3), itbbu3(4) |
nextLearnTime | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.3 | integer | read-only |
Time of next scheduled lean cycle (seconds path 1/1/2000) |
absStateOfCharge | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.4 | integer | read-only |
Predicted remaining capacity expressed as % of DesignCapacity() (0-100). Value of -1 means not supported |
fullChargeCapacity | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.5 | integer | read-only |
Predicted pack capacity when it is fully charged in mAh |
averageEmptyTime | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.6 | integer | read-only |
One-minute rolling average of the predicted remaining battery life. Value of -1 means not supported |
cycleCount | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.7 | integer | read-only |
Number of charge cycles the battery has experienced. Value of -1 means not supported |
firmwareStatus | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.8 | displaystring | read-only |
condition of battery in following order: packMissing(0/1) voltageLow(0/1) temperatureHigh(0/1) chargeActive(0/1) dischargeActive(0/1) learnCycleRequested(0/1) learnCycleActive(0/1) learnCycleFailed(0/1) learnCycleTimeout(0/1) i2cErrorsDetected(0/1) Only enabled(1) values will be shown |
voltage | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.9 | integer | read-only |
Accurate battery terminal voltage in mV, resolution of 1mV |
autoLearnPeriod | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.10 | integer | read-only |
Time (in seconds) between learn cycles (0 to disable auto learn) |
relStateOfCharge | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.11 | integer | read-only |
Predicted remaining capacity expressed as % of FullChargeCapacity() (0-100). Value of -1 means not supported |
capacityRemain | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.12 | integer | read-only |
Predicted charge or energy remaining in the battery in mAh |
runTimeToEmpty | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.13 | integer | read-only |
(in minutes)Relative gain or loss in remaining life in response to change in power policy. Value of -1 means not supported |
avgTimeToFull | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.14 | integer | read-only |
One-minute rolling average of predicted remaining time to full charge. Value of -1 means not supported |
errorMargin | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.15 | integer | read-only |
Expected margin of error (%) in charge calculation (2-100). Value of -1 means not supported |
temperature | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.16 | integer | read-only |
Battery temperature in degree Centigrade |
mfgName | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.17 | displaystring | read-only |
Battery manufacturer's name |
deviceName | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.18 | displaystring | read-only |
Battery name |
serialNumber | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.19 | displaystring | read-only |
Battery serialNumber |
chargerStatus | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.20 | integer | read-only |
Battery charger status. Values: N/A(-1), off(0), complete(1), progress(2) |
adpID | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.21 | integer | read-only |
The adapter id where BBU is attached |
remainingCapAlarm | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.22 | integer | read-only |
Remaining capacity to alarm. Value of -1 means not supported |
remainingTimeAlarm | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.23 | integer | read-only |
Remaining time to alarm. Value of -1 means not supported |
bbu_current | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.24 | integer | read-only |
Current(In mA) being supplied (or accepted) through the terminals of the battery |
gasGaugeStatus | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.25 | integer | read-only |
Gas guage status |
device | 1.3.6.1.4.1.3582.5.1.4.2 | |||
physicalDriveInfo | 1.3.6.1.4.1.3582.5.1.4.2.1 | |||
pdNumber | 1.3.6.1.4.1.3582.5.1.4.2.1.1 | gauge | read-only |
The present number of rows in the physicalDrive table. |
pdTable | 1.3.6.1.4.1.3582.5.1.4.2.1.2 | no-access |
A List of physicalDrive Entries containing Information/Properties about the drives |
|
1.3.6.1.4.1.3582.5.1.4.2.1.2.1 | no-access |
An Entry in the Device Table. |
||
pdIndex | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.1 | integer | read-only |
The unique ID |
physDevID | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.2 | integer | read-only |
The Device ID |
oemSupported | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.3 | integer | read-only |
Drive support by the OEM (OEM-specific checks) Values: notSupported(1), supported(0) |
scsiDevType | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.4 | integer | read-only |
Type of this Device. Values: disk(0), tape(1), printer(2), processor(3), cdrom(5), scanner(6), optical(7), enclosure(13), dvd(10), unknown(31) |
connectedAdapterPort | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.5 | integer | read-only |
Adapter port to which the device is connected. |
deviceSpeed | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.6 | integer | read-only |
Maximum supported speed. Values: speed_unknown(0), speed_1p5G(1), speed_3G(2),speed_6G(3) |
mediaErrCount | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.7 | integer | read-only |
Error count of the device |
otherErrCount | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.8 | integer | read-only |
other error count of the device |
predFailCount | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.9 | integer | read-only |
Predictive fail count of the device |
pdState | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.10 | integer | read-only |
Firmware's interpretation of drive state. Values: unconfigured_good(0), unconfigured_bad(1), hot_spare(2), offline(16), failed(17), rebuild(20), online(24),copyback(32),system(64) |
disabledForRemoval | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.11 | integer | read-only |
If true, drive is ready for removal. Values: false(0), true(1) |
linkSpeed | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.12 | integer | read-only |
Negotiated link speed. Values: speed_unknown(0), speed_1p5G(1), speed_3G(2), speed_6G(3) |
pdSupportFlags | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.13 | displaystring | read-only |
1st Byte:forcedPDGUID(0/1),2nd Byte:inVD(0/1),3rd Byte:isGlobalSpare(0/1),4th Byte:isSpare(0/1),5th Byte:isForeign(0/1),6th Byte:intf(0-Unknown, 1-parallel SCSI, 2-SAS, 3-SATA, 4-FC).A comma delimited list will appear. |
pdSasAddr | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.14 | displaystring | read-only |
Device SAS addresses. Comma separeted for multiple address |
rawSize | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.15 | integer | read-only |
Size(MB) before COD and coercion |
nonCoercedSize | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.16 | integer | read-only |
Size(MB) after COD is reserved but before coercion |
coercedSize | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.17 | integer | read-only |
Size(MB) after COD is reserved and after coercion |
enclDeviceId | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.18 | integer | read-only |
Enclosure's device Id (in decimal); if device is not within enclosure value is -1 |
enclIndex | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.19 | integer | read-only |
Firmware internal enclosure index |
slotNumber | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.20 | integer | read-only |
Slot number of this drive, if this Physical Drive is an enclosure then -1 |
pdOperationProgress | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.21 | displaystring | read-only |
% Progress is %. e.g. Rebuild progress is 10% |
pdAdpID | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.22 | integer | read-only |
Controller id where this Physical Drive is attached |
operationSupport | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.23 | displaystring | read-only |
Online,Offline,Failed,Bad,Uncofigured good,Unconfigured bad, Spare,Spare,replaceMissing,markMissing,startRebuild,stopRebuild, locate,stopSecureEraseNonSED,FWDownloadAllowed |
vendorID | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.24 | displaystring | read-only |
Vendor ID |
productID | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.25 | displaystring | read-only |
Product ID |
pdFwversion | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.26 | displaystring | read-only |
Physical drive firmware version |
pdSerialNumber | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.27 | displaystring | read-only |
Physical drive serial number |
diskType | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.28 | integer | read-only |
Type of the disk : 0-Unknown, 1-parallel SCSI, 2-SAS, 3-SATA, 4-FC |
partnerDevId | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.29 | integer | read-only |
If drive is in an enclosure with dual paths,This is Partner Device ID. In all other cases INVALID(-1) |
mediatype | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.30 | integer | read-only |
Media Type HDD(0),SSD(1) |
oemCertified | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.31 | integer | read-only |
Indicates whether device is certified(0) or not(1) |
pdTemperature | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.32 | integer | read-only |
Physical Drive temperature in Celsius |
piType | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.33 | integer | read-only |
SAS Protection Information Type .No SAS protection type used(0) ,SAS PI Type 1(1) ,SAS PI Type 2(2) ,SAS PI Type 3(3) ,Reserved SAS PI Type 4(4) ,Reserved SAS PI Type 5(5) ,Reserved SAS PI Type 6(6) ,Reserved SAS PI Type 7(7). |
userDataBlockSize | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.34 | integer | read-only |
Number of bytes of user data in LBA |
cage | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.35 | integer | read-only |
Current Cage that holds the SSD |
location | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.36 | displaystring | read-only |
Current location of SSD 0 - Upper, 1 - Lower |
whtemperature | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.37 | integer | read-only |
Temperature of each SSD |
flashType | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.38 | displaystring | read-only |
Flash Type being used (SLC / MLC / EMLC) |
lifeCurveStatus | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.39 | displaystring | read-only |
100 - No throttling being done, 90 - SSD is being throttled |
sSDLifeLeft | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.40 | displaystring | read-only |
Percentage of SSD life left |
virtualDevice | 1.3.6.1.4.1.3582.5.1.4.3 | |||
vdInfo | 1.3.6.1.4.1.3582.5.1.4.3.1 | |||
vdNumber | 1.3.6.1.4.1.3582.5.1.4.3.1.1 | gauge | read-only |
The present number of rows in the virtualDrive table. |
vdTable | 1.3.6.1.4.1.3582.5.1.4.3.1.2 | no-access |
A List of Virtual Drive Entries containing Information/Properties about the virtualDrive. |
|
1.3.6.1.4.1.3582.5.1.4.3.1.2.1 | no-access |
An Entry in the virtualDrive Table. |
||
virtualDevID | 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.1 | integer | read-only |
The unique Virtual Drive ID |
size | 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.2 | integer | read-only |
Total size in MB of the drive |
clusterOwnerDeviceId | 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.3 | integer | read-only |
Virtual Drive owner's device Id |
targetId | 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.4 | integer | read-only |
Virtual Drive target id (i.e. 0 to 63) |
state | 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.5 | integer | read-only |
Virtual Drive state. Values: offline(0), partially_degraded(1), degraded(2), optimal(3) |
name | 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.6 | displaystring | read-only |
Virtual Drive name |
defaultCachePolicy | 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.7 | integer | read-only |
Default cache policy settings. Values: direct_io(0), cached_io(1) |
vdAccessPolicy | 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.8 | integer | read-only |
Access policy settings. Values: access_rw(0), access_read_only(2), access_blocked(3) |
vdDiskCachePolicy | 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.9 | integer | read-write |
Physical disk cache policy. Values: enable(1), disable(2) |
bgiState | 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.10 | integer | read-only |
BGI state on this VD. Values disable(1), enable(0) |
prl | 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.11 | integer | read-only |
Primay raid level. Values: 0(RAID-0), 1(RAID-1), 3(RAID-3), 4(RAID-4), 5(RAID-5), 6(RAID-6),15(Single Disk or JBOD), 17(RAID-1E/10), 21(RAID-5E), 31(Concatenation),37(RAID-5EEE) |
rLQ | 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.12 | integer | read-only |
Raid level qualifier |
sRL | 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.13 | integer | read-only |
Secondary raid level. Values: 0(Stripped), 1(Mirrored), 2(Concatenated), 3(Spanned), -1(Not Supported for IR2) |
stripeSize | 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.14 | integer | read-only |
Stripe Size. 0(512B),1(1K),2(2K),3(4K),4(8K),5(16K),6(32),7(64K),8(128K) ... 11(1MB) etc |
numDrives | 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.15 | integer | read-only |
Number of drivers per span |
spanDepth | 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.16 | integer | read-only |
Number of spans. If only one array then it is considered as 1 span |
initState | 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.17 | integer | read-only |
0=no init, 1=quick init, 2=full init |
currentCachePolicy | 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.18 | integer | read-only |
Default cache policy settings. Values: direct_io(0), cached_io(1) |
operationProgress | 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.19 | displaystring | read-only |
Progress % for operation x/ No operation in progress |
vdAdpID | 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.20 | integer | read-only |
Controller id where this vd is present |
vdSpanInfo | 1.3.6.1.4.1.3582.5.1.4.3.2 | |||
vdSpanNumber | 1.3.6.1.4.1.3582.5.1.4.3.2.1 | gauge | read-only |
The present number of rows in the virtualDrive table. |
vdSpanTable | 1.3.6.1.4.1.3582.5.1.4.3.2.2 | no-access |
A List of span Entries containing Information/Properties vd span. |
|
1.3.6.1.4.1.3582.5.1.4.3.2.2.1 | no-access |
An Entry in the vdSpan Table. |
||
spanID | 1.3.6.1.4.1.3582.5.1.4.3.2.2.1.1 | integer | read-only |
The unique Span ID |
vDevID | 1.3.6.1.4.1.3582.5.1.4.3.2.2.1.2 | integer | read-only |
The Virtual Device ID |
startBlock | 1.3.6.1.4.1.3582.5.1.4.3.2.2.1.3 | integer | read-only |
Span physical disk starting block |
numBlocks | 1.3.6.1.4.1.3582.5.1.4.3.2.2.1.4 | displaystring | read-only |
Span physical disk block count |
vdsArrayRef | 1.3.6.1.4.1.3582.5.1.4.3.2.2.1.5 | integer | read-only |
Array reference (index) |
spAdpId | 1.3.6.1.4.1.3582.5.1.4.3.2.2.1.6 | integer | read-only |
Adapter where the span will be found |
arrayInfo | 1.3.6.1.4.1.3582.5.1.4.3.3 | |||
arrayNumber | 1.3.6.1.4.1.3582.5.1.4.3.3.1 | gauge | read-only |
The present number of rows in the array table. |
arrayTable | 1.3.6.1.4.1.3582.5.1.4.3.3.2 | no-access |
A List of array Entries containing Information/Properties about the arrays. |
|
1.3.6.1.4.1.3582.5.1.4.3.3.2.1 | no-access |
An Entry in the array Table. |
||
arrayID | 1.3.6.1.4.1.3582.5.1.4.3.3.2.1.1 | integer | read-only |
The unique array ID |
arrSize | 1.3.6.1.4.1.3582.5.1.4.3.3.2.1.2 | integer | read-only |
Size in MB |
arrNumDrives | 1.3.6.1.4.1.3582.5.1.4.3.3.2.1.3 | integer | read-only |
Number of drives for this array |
arrayRef | 1.3.6.1.4.1.3582.5.1.4.3.3.2.1.4 | integer | read-only |
Tag for the array |
pdList | 1.3.6.1.4.1.3582.5.1.4.3.3.2.1.5 | displaystring | read-only |
Space separated pd identification. e.g. {devID devID devID} etc |
arrAdpId | 1.3.6.1.4.1.3582.5.1.4.3.3.2.1.6 | integer | read-only |
Adapter where the array will be found |
spareInfo | 1.3.6.1.4.1.3582.5.1.4.3.4 | |||
spareDevNumber | 1.3.6.1.4.1.3582.5.1.4.3.4.1 | gauge | read-only |
The present number of rows in the sparepool table. |
spareTable | 1.3.6.1.4.1.3582.5.1.4.3.4.2 | no-access |
A List of sparepool Entries containing Information/Properties about the spare drive |
|
1.3.6.1.4.1.3582.5.1.4.3.4.2.1 | no-access |
An Entry in the sparepool Table. |
||
spareID | 1.3.6.1.4.1.3582.5.1.4.3.4.2.1.1 | integer | read-only |
The unique Index |
deviceIdentification | 1.3.6.1.4.1.3582.5.1.4.3.4.2.1.2 | integer | read-only |
The Device ID |
spareType | 1.3.6.1.4.1.3582.5.1.4.3.4.2.1.3 | displaystring | read-only |
Spare type. isDedicated(0/1)isRevertible(0/1)isEnclAffinity(0/1). 1 implies particular feature is enable and 0 represent feature is disable. |
arrayCount | 1.3.6.1.4.1.3582.5.1.4.3.4.2.1.4 | integer | read-only |
The number of arrays to which the PD can be dedicated |
arrRef | 1.3.6.1.4.1.3582.5.1.4.3.4.2.1.5 | displaystring | read-only |
Comma separated array ids. e.g. 2,4,5 etc |
sprAdpId | 1.3.6.1.4.1.3582.5.1.4.3.4.2.1.6 | integer | read-only |
Adapter where the spare will be found |
enclosure | 1.3.6.1.4.1.3582.5.1.4.4 | |||
enclosureInfo | 1.3.6.1.4.1.3582.5.1.4.4.1 | |||
enclosureNumber | 1.3.6.1.4.1.3582.5.1.4.4.1.1 | gauge | read-only |
The present number of rows in the enclosure table. |
enclosureTable | 1.3.6.1.4.1.3582.5.1.4.4.1.2 | no-access |
A List of enclosure Entries containing Information/Properties about the enclosures in the system. |
|
1.3.6.1.4.1.3582.5.1.4.4.1.2.1 | no-access |
An Entry in the enclosure table. |
||
enclosureID | 1.3.6.1.4.1.3582.5.1.4.4.1.2.1.1 | integer | read-only |
EnclosureID for this enclosure.(Unique) |
deviceId | 1.3.6.1.4.1.3582.5.1.4.4.1.2.1.2 | integer | read-only |
Enclosure device Id. |
enclosureIndex | 1.3.6.1.4.1.3582.5.1.4.4.1.2.1.3 | integer | read-only |
Firmware internal enclosure index |
slotCount | 1.3.6.1.4.1.3582.5.1.4.4.1.2.1.4 | integer | read-only |
Number of slots |
psCount | 1.3.6.1.4.1.3582.5.1.4.4.1.2.1.5 | integer | read-only |
Number of power supplies |
fanCount | 1.3.6.1.4.1.3582.5.1.4.4.1.2.1.6 | integer | read-only |
Number of fans |
tempSensorCount | 1.3.6.1.4.1.3582.5.1.4.4.1.2.1.7 | integer | read-only |
Number of temperature sensors |
alarmCount | 1.3.6.1.4.1.3582.5.1.4.4.1.2.1.8 | integer | read-only |
Number of alarms |
simCount | 1.3.6.1.4.1.3582.5.1.4.4.1.2.1.9 | integer | read-only |
Number of SIM modules |
isFault | 1.3.6.1.4.1.3582.5.1.4.4.1.2.1.10 | integer | read-only |
Enclosure has entered a FAULT state or not. Values: false(0), true(1) |
pdCount | 1.3.6.1.4.1.3582.5.1.4.4.1.2.1.11 | integer | read-only |
Number of physical drives present |
pdIds | 1.3.6.1.4.1.3582.5.1.4.4.1.2.1.12 | displaystring | read-only |
Physical drive deviceId's comma separated. |
encAdpID | 1.3.6.1.4.1.3582.5.1.4.4.1.2.1.13 | integer | read-only |
Adapter ID where this enclosure is connected |
enclosureFanInfo | 1.3.6.1.4.1.3582.5.1.4.4.2 | |||
enclosureFanNumber | 1.3.6.1.4.1.3582.5.1.4.4.2.1 | gauge | read-only |
The present number of rows in the enclosure fan table. |
enclosureFanTable | 1.3.6.1.4.1.3582.5.1.4.4.2.2 | no-access |
A List of fan Entries containing Information/Properties about the enclosureFan. |
|
1.3.6.1.4.1.3582.5.1.4.4.2.2.1 | no-access |
An Entry in the enclosureFan table. |
||
fanID | 1.3.6.1.4.1.3582.5.1.4.4.2.2.1.1 | integer | read-only |
ID for this enclosureFan.(Unique) |
enclosureId | 1.3.6.1.4.1.3582.5.1.4.4.2.2.1.2 | integer | read-only |
Enclosure ID where the fan is attached |
fanStatus | 1.3.6.1.4.1.3582.5.1.4.4.2.2.1.3 | integer | read-only |
status of the device Enumeration: 'status-nonCritical': 3, 'status-not-installed': 5, 'status-unrecoverable': 4, 'status-critical': 2, 'status-ok': 1, 'status-unknown': 6, 'status-not-available': 7. |
enclosureSlotInfo | 1.3.6.1.4.1.3582.5.1.4.4.3 | |||
enclosureSlotNum | 1.3.6.1.4.1.3582.5.1.4.4.3.1 | gauge | read-only |
The present number of rows in the enclosure slot table. |
enclosureSlotTable | 1.3.6.1.4.1.3582.5.1.4.4.3.2 | no-access |
A List of slot Entries containing Information/Properties about the enclosure slots. |
|
1.3.6.1.4.1.3582.5.1.4.4.3.2.1 | no-access |
An Entry in the enclosureSlot table. |
||
slotID | 1.3.6.1.4.1.3582.5.1.4.4.3.2.1.1 | integer | read-only |
ID for this slot.(Unique) |
sltEncId | 1.3.6.1.4.1.3582.5.1.4.4.3.2.1.2 | integer | read-only |
Enclosure ID where the slot |
slotStatus | 1.3.6.1.4.1.3582.5.1.4.4.3.2.1.3 | integer | read-only |
status of the device. Values: status-ok(1), status-critical(2), status-nonCritical(3), status-unrecoverable(4), status-not-installed(5), status-unknown(6), status-not-available(7) Enumeration: 'status-nonCritical': 3, 'status-not-installed': 5, 'status-unrecoverable': 4, 'status-critical': 2, 'status-ok': 1, 'status-unknown': 6, 'status-not-available': 7. |
enclosurePSInfo | 1.3.6.1.4.1.3582.5.1.4.4.4 | |||
enclosurePSNumber | 1.3.6.1.4.1.3582.5.1.4.4.4.1 | gauge | read-only |
The present number of rows in the enclosure fan table. |
enclosurePSTable | 1.3.6.1.4.1.3582.5.1.4.4.4.2 | no-access |
A List of powerSupply Entries containing Information/Properties about the enclosure powerSupply |
|
1.3.6.1.4.1.3582.5.1.4.4.4.2.1 | no-access |
An Entry in the powerSupply table. |
||
powerSupplyID | 1.3.6.1.4.1.3582.5.1.4.4.4.2.1.1 | integer | read-only |
ID for this powerSupply.(Unique) |
psEnclosureId | 1.3.6.1.4.1.3582.5.1.4.4.4.2.1.2 | integer | read-only |
Enclosure id for the powerSupply |
powerSupplyStatus | 1.3.6.1.4.1.3582.5.1.4.4.4.2.1.3 | integer | read-only |
status of the power Supply Enumeration: 'status-nonCritical': 3, 'status-not-installed': 5, 'status-unrecoverable': 4, 'status-critical': 2, 'status-ok': 1, 'status-unknown': 6, 'status-not-available': 7. |
enclosureTSInfo | 1.3.6.1.4.1.3582.5.1.4.4.5 | |||
enclosureTSNumber | 1.3.6.1.4.1.3582.5.1.4.4.5.1 | gauge | read-only |
The present number of rows in the enclosure fan table. |
enclosureTSTable | 1.3.6.1.4.1.3582.5.1.4.4.5.2 | no-access |
A List of TempSensor Entries containing Information/Properties about the enclosure TempSensor |
|
1.3.6.1.4.1.3582.5.1.4.4.5.2.1 | no-access |
An Entry in the adapter table. |
||
tempSensorID | 1.3.6.1.4.1.3582.5.1.4.4.5.2.1.1 | integer | read-only |
ID for this TempSensor.(Unique) |
encId | 1.3.6.1.4.1.3582.5.1.4.4.5.2.1.2 | integer | read-only |
enclosure id for this TempSensor |
tempSensorStatus | 1.3.6.1.4.1.3582.5.1.4.4.5.2.1.3 | integer | read-only |
status of this tempSensor Enumeration: 'status-nonCritical': 3, 'status-not-installed': 5, 'status-unrecoverable': 4, 'status-critical': 2, 'status-ok': 1, 'status-unknown': 6, 'status-not-available': 7. |
tsTemperature | 1.3.6.1.4.1.3582.5.1.4.4.5.2.1.4 | integer | read-only |
Current temperature in degree Centigrade |
enclosureAlarmInfo | 1.3.6.1.4.1.3582.5.1.4.4.6 | |||
enclosureAlarmNumber | 1.3.6.1.4.1.3582.5.1.4.4.6.1 | gauge | read-only |
The present number of rows in the enclosure fan table. |
enclosureAlarmTable | 1.3.6.1.4.1.3582.5.1.4.4.6.2 | no-access |
A List of Alarm Entries containing Information/Properties about enclosure Alarms |
|
1.3.6.1.4.1.3582.5.1.4.4.6.2.1 | no-access |
An Entry in the enclosureAlarm table. |
||
alarmID | 1.3.6.1.4.1.3582.5.1.4.4.6.2.1.1 | integer | read-only |
ID for this Alarm.(Unique) |
almEnclosureId | 1.3.6.1.4.1.3582.5.1.4.4.6.2.1.2 | integer | read-only |
Enclosure id where the Alarm is attached |
alarmStatus | 1.3.6.1.4.1.3582.5.1.4.4.6.2.1.3 | integer | read-only |
Status of the alarm Enumeration: 'status-nonCritical': 3, 'status-not-installed': 5, 'status-unrecoverable': 4, 'status-critical': 2, 'status-ok': 1, 'status-unknown': 6, 'status-not-available': 7. |
enclosureSIMInfo | 1.3.6.1.4.1.3582.5.1.4.4.7 | |||
enclosureSIMNumber | 1.3.6.1.4.1.3582.5.1.4.4.7.1 | gauge | read-only |
The present number of rows in the enclosure fan table. |
enclosureSIMTable | 1.3.6.1.4.1.3582.5.1.4.4.7.2 | no-access |
A List of SIM Entries containing Information/Properties about enclosure SIMs |
|
1.3.6.1.4.1.3582.5.1.4.4.7.2.1 | no-access |
An Entry in the enclosureSIM table. |
||
simID | 1.3.6.1.4.1.3582.5.1.4.4.7.2.1.1 | integer | read-only |
ID for this SIM.(Unique) |
simEnclosureId | 1.3.6.1.4.1.3582.5.1.4.4.7.2.1.2 | integer | read-only |
Enclosure id where the SIM is attached |
simStatus | 1.3.6.1.4.1.3582.5.1.4.4.7.2.1.3 | integer | read-only |
Number of Logical Drives Configured on this Adapter. Enumeration: 'status-nonCritical': 3, 'status-not-installed': 5, 'status-unrecoverable': 4, 'status-critical': 2, 'status-ok': 1, 'status-unknown': 6, 'status-not-available': 7. |
topology | 1.3.6.1.4.1.3582.5.1.4.5 | |||
phyInfo | 1.3.6.1.4.1.3582.5.1.4.5.1 | |||
phyNumber | 1.3.6.1.4.1.3582.5.1.4.5.1.1 | gauge | read-only |
The present number of rows in the Phy table. |
phyTable | 1.3.6.1.4.1.3582.5.1.4.5.1.2 | no-access |
A List of phy Entries containing Information/Properties about the sas topology in the system. |
|
1.3.6.1.4.1.3582.5.1.4.5.1.2.1 | no-access |
An Entry in the Phy table. |
||
phyIndex | 1.3.6.1.4.1.3582.5.1.4.5.1.2.1.1 | integer | read-only |
Index for this phy.(Unique) |
deviceIndex | 1.3.6.1.4.1.3582.5.1.4.5.1.2.1.2 | integer | read-only |
Index of the device in tDeviceTable where the phy is attached |
deviceType | 1.3.6.1.4.1.3582.5.1.4.5.1.2.1.3 | integer | read-only |
Type of device attached to this phy NO_DEVICE = 0, IOC(1), EDGE_EXPANDER(2), FANOUT_EXPANDER(3),END_DEVICE(4) |
phyID | 1.3.6.1.4.1.3582.5.1.4.5.1.2.1.4 | integer | read-only |
The phy ID of the attached device |
deviceOffset | 1.3.6.1.4.1.3582.5.1.4.5.1.2.1.5 | integer | read-only |
The memory offset where the node of the device that is attached to this phy starts. |
phyPos | 1.3.6.1.4.1.3582.5.1.4.5.1.2.1.6 | integer | read-only |
Position of the Phy in device attached. |
devicesInTopology | 1.3.6.1.4.1.3582.5.1.4.5.2 | |||
tDeviceNumber | 1.3.6.1.4.1.3582.5.1.4.5.2.1 | gauge | read-only |
The present number of rows in the topology Device table. |
tDeviceTable | 1.3.6.1.4.1.3582.5.1.4.5.2.2 | no-access |
A List of device Entries containing Information/Properties about the sas topology in the system. |
|
1.3.6.1.4.1.3582.5.1.4.5.2.2.1 | no-access |
An Entry in the tDevice table. |
||
tDeviceIndex | 1.3.6.1.4.1.3582.5.1.4.5.2.2.1.1 | integer | read-only |
Index for this device.(Unique) |
contID | 1.3.6.1.4.1.3582.5.1.4.5.2.2.1.2 | integer | read-only |
Adapter ID where this device is attached |
tDeviceId | 1.3.6.1.4.1.3582.5.1.4.5.2.2.1.3 | integer | read-only |
Device ID. |
tDeviceType | 1.3.6.1.4.1.3582.5.1.4.5.2.2.1.4 | integer | read-only |
NO_DEVICE = 0, IOC(1), EDGE_EXPANDER(2), FANOUT_EXPANDER(3),END_DEVICE(4) |
tParentIndex | 1.3.6.1.4.1.3582.5.1.4.5.2.2.1.5 | integer | read-only |
Index of the parent device in the table where this device is connected. -1 if it root device. |
tNumPhy | 1.3.6.1.4.1.3582.5.1.4.5.2.2.1.6 | integer | read-only |
Total no of Phy present in this device |
tSASAddr | 1.3.6.1.4.1.3582.5.1.4.5.2.2.1.7 | displaystring | read-only |
Device SAS addresses. Comma separeted for multiple address |
tDevDescription | 1.3.6.1.4.1.3582.5.1.4.5.2.2.1.8 | displaystring | read-only |
Detailed description of the Device. |
lsi_SAS_Traps | 1.3.6.1.4.1.3582.5.1.4.6 | |||
atAdpNumber | 1.3.6.1.4.1.3582.5.1.4.6.1001 | integer | read-only |
Adapter ID for which Trap is generated. |
atAlarmState | 1.3.6.1.4.1.3582.5.1.4.6.1002 | integer | read-only |
Alarm disabled(0)/enabled(1) |
atRate | 1.3.6.1.4.1.3582.5.1.4.6.1003 | integer | read-only |
BGI/Check Consistency/Rebuild/Patrol Read/Reconstruction Rate |
atFlashImageName | 1.3.6.1.4.1.3582.5.1.4.6.1004 | displaystring | read-only |
Flash Image Name |
atSensorNum | 1.3.6.1.4.1.3582.5.1.4.6.1005 | integer | read-only |
Sensor Number |
atThreshold | 1.3.6.1.4.1.3582.5.1.4.6.1006 | integer | read-only |
Threshold |
atTemperature | 1.3.6.1.4.1.3582.5.1.4.6.1007 | integer | read-only |
Temperature Exceeded |
devLife | 1.3.6.1.4.1.3582.5.1.4.6.1008 | integer | read-only |
Drive Life |
atWarningLevel | 1.3.6.1.4.1.3582.5.1.4.6.1009 | integer | read-only |
Warning Level |
atErrorLevel | 1.3.6.1.4.1.3582.5.1.4.6.1010 | integer | read-only |
Error Level |
throttle | 1.3.6.1.4.1.3582.5.1.4.6.1011 | integer | read-only |
Throttle |
percentThrottle | 1.3.6.1.4.1.3582.5.1.4.6.1012 | integer | read-only |
Percent Throttle |
pciSlotAvailPower | 1.3.6.1.4.1.3582.5.1.4.6.1013 | integer | read-only |
PCI Slot Avail Power |
flags | 1.3.6.1.4.1.3582.5.1.4.6.1014 | integer | read-only |
Flags SENSOR(1)|SLOT(2) |
sensorOrSlot | 1.3.6.1.4.1.3582.5.1.4.6.1015 | integer | read-only |
Sensor Or Slot depending on the value of thr Flag |
currTemp | 1.3.6.1.4.1.3582.5.1.4.6.1016 | integer | read-only |
Current Temp |
thresholdTemp | 1.3.6.1.4.1.3582.5.1.4.6.1017 | integer | read-only |
Threshold Temp |
vdNum | 1.3.6.1.4.1.3582.5.1.4.6.1101 | integer | read-only |
Virtual Drive Target ID for which Trap is generated. |
vdSeq | 1.3.6.1.4.1.3582.5.1.4.6.1102 | integer | read-only |
Virtual Drive Sequence no for which Trap is generated. |
vdProg | 1.3.6.1.4.1.3582.5.1.4.6.1103 | integer | read-only |
progress % |
vdCachePolicyChangeReason | 1.3.6.1.4.1.3582.5.1.4.6.1104 | displaystring | read-only |
Virtual Drive cache policy. |
vdNewState | 1.3.6.1.4.1.3582.5.1.4.6.1105 | integer | read-only |
Virtual Drive state. Values are: offline(0),partially-degraded(1),degraded(2),optimal(3) |
vdOldState | 1.3.6.1.4.1.3582.5.1.4.6.1106 | integer | read-only |
Virtual Drive state. Values are: offline(0),partially-degraded(1),degraded(2),optimal(3) |
pdID | 1.3.6.1.4.1.3582.5.1.4.6.1201 | integer | read-only |
Device ID for which Trap is generated. |
pdEncIndex | 1.3.6.1.4.1.3582.5.1.4.6.1202 | integer | read-only |
Enclosure index(0 means not within an enclosure) for which Trap is generated. |
pdSlotNo | 1.3.6.1.4.1.3582.5.1.4.6.1203 | integer | read-only |
Slot no for the enclosure |
pdNewState | 1.3.6.1.4.1.3582.5.1.4.6.1204 | integer | read-only |
Physical Drive state. Values are: unconfigured-good(0),unconfigured-bad(1),hot-spare(2),offline(16),failed(17),rebuild(20),online(24),copyback(32),system(64) |
pdOldState | 1.3.6.1.4.1.3582.5.1.4.6.1205 | integer | read-only |
Physical Drive state. Values are: unconfigured-good(0),unconfigured-bad(1),hot-spare(2),offline(16),failed(17),rebuild(20),online(24),copyback(32),system(64) |
pdCDBData | 1.3.6.1.4.1.3582.5.1.4.6.1206 | displaystring | read-only |
CDB Data. |
pdSenseData | 1.3.6.1.4.1.3582.5.1.4.6.1207 | displaystring | read-only |
Sence Data. |
irAdpAlarmStateEnabled | 1.3.6.1.4.1.3582.5.1.4.60.7001 |
Alarm has been enabled by user for Adapter $1 |
||
irAdpBGIRateChanged | 1.3.6.1.4.1.3582.5.1.4.60.7002 |
Background initialization rate changed to $1 for Adapter $2 |
||
irAdpCacheDiscarded | 1.3.6.1.4.1.3582.5.1.4.60.7003 |
Controller $1 cache discarded due to memory/battery problems |
||
irAdpCacheRebootCantRecover | 1.3.6.1.4.1.3582.5.1.4.60.7004 |
Unable to recover cache data due to configuration mismatch for Adapter $1 |
||
irAdpCacheRebootRecover | 1.3.6.1.4.1.3582.5.1.4.60.7005 |
Cache data recovered successfully for Adapter $1 |
||
irAdpCacheVersionMismatch | 1.3.6.1.4.1.3582.5.1.4.60.7006 |
Controller cache discarded due to firmware version incompatibility for Adapter $1 |
||
irAdpCCRateChanged | 1.3.6.1.4.1.3582.5.1.4.60.7007 |
Consistency Check rate changed to $1 for Adapter $2 |
||
irAdpFlashBadImage | 1.3.6.1.4.1.3582.5.1.4.60.7008 |
Flash downloaded image corrupted for Adapter $1 |
||
irAdpFlashEraseError | 1.3.6.1.4.1.3582.5.1.4.60.7009 |
Flash erase error for Adapter $1 |
||
irAdpFlashEraseTimeout | 1.3.6.1.4.1.3582.5.1.4.60.7010 |
Flash timeout during erase for Adapter $1 |
||
irAdpFlashGeneralError | 1.3.6.1.4.1.3582.5.1.4.60.7011 |
Flash error for Adapter $1 |
||
irAdpFlashImage | 1.3.6.1.4.1.3582.5.1.4.60.7012 |
Flashing image: $1 for Adapter $2 |
||
irAdpFlashOK | 1.3.6.1.4.1.3582.5.1.4.60.7013 |
Flash of new firmware image(s)complete for Adapter $1 |
||
irAdpFlashProgramError | 1.3.6.1.4.1.3582.5.1.4.60.7014 |
Flash programming error for Adapter $1 |
||
irAdpFlashProgramTimeout | 1.3.6.1.4.1.3582.5.1.4.60.7015 |
Flash timeout during programming for Adapter $1 |
||
irAdpLogCleared | 1.3.6.1.4.1.3582.5.1.4.60.7016 |
Event log cleared for Adapter $1 |
||
irAdpLogWrapped | 1.3.6.1.4.1.3582.5.1.4.60.7017 |
Event log wrapped for Adapter $1 |
||
irAdpPatrolReadComplete | 1.3.6.1.4.1.3582.5.1.4.60.7018 |
Patrol Read complete for Adapter $1 |
||
irAdpPatrolReadPaused | 1.3.6.1.4.1.3582.5.1.4.60.7019 |
Patrol Read paused for Adapter $1 |
||
irAdpPatrolReadResumed | 1.3.6.1.4.1.3582.5.1.4.60.7020 |
Patrol Read resumed for Adapter $1 |
||
irAdpPatrolReadStarted | 1.3.6.1.4.1.3582.5.1.4.60.7021 |
Patrol Read started for Adapter $1 |
||
irAdpShutdown | 1.3.6.1.4.1.3582.5.1.4.60.7022 |
Shutdown command received for Adapter $1 |
||
irAdpHibernate | 1.3.6.1.4.1.3582.5.1.4.60.7023 |
Hibernate command received for Adapter $1 |
||
irAdpCrash | 1.3.6.1.4.1.3582.5.1.4.60.7024 |
Fatal error received for Adapter $1 |
||
irAdpRRChanged | 1.3.6.1.4.1.3582.5.1.4.60.7025 |
Rebuild rate changed to $1 for Adapter $2 |
||
irAdpPRRateChanged | 1.3.6.1.4.1.3582.5.1.4.60.7026 |
Patrol Read rate changed to $1 for Adapter $2 |
||
irAdpAlarmStateDisabled | 1.3.6.1.4.1.3582.5.1.4.60.7027 |
Alarm has been disabled by user for Adapter $1 |
||
irAdpConfigCleared | 1.3.6.1.4.1.3582.5.1.4.60.7028 |
Configuration cleared for Adapter $1 |
||
irAdpReconRateChanged | 1.3.6.1.4.1.3582.5.1.4.60.7029 |
Reconstruction rate changed to $1 for Adapter $2 |
||
irAdpDefault | 1.3.6.1.4.1.3582.5.1.4.60.7030 |
Factory defaults restored for Adapter $1 |
||
irAdpThresholdsExceededCritical | 1.3.6.1.4.1.3582.5.1.4.60.7031 |
Adapter $1 on sensor $2 has exceeded critical temperature threshold $3 Temperature $4 |
||
irAdpThresholdsExceededWarning | 1.3.6.1.4.1.3582.5.1.4.60.7032 |
Adapter $1 on sensor $2 has exceeded warning temperature threshold $3 Temperature $4 |
||
irAdpBRMFailed | 1.3.6.1.4.1.3582.5.1.4.60.7033 |
Backup Rail Monitor has failed for Adapter $1 |
||
irAdpSSDLifeExhausted | 1.3.6.1.4.1.3582.5.1.4.60.7034 |
Adapter $1 SSD Life for SlotNo $2 PD ID $3 Dev Life $4 Warning Level $5 Error Level $6 |
||
irAdpSSDLifeWarning | 1.3.6.1.4.1.3582.5.1.4.60.7035 |
Adapter $1 SSD Life for SlotNo $2 PD ID $3 Dev Life $4 Warning Level $5 Error Level $6 |
||
irAdpSSDThrottlingRemoved | 1.3.6.1.4.1.3582.5.1.4.60.7036 |
Throttling Removed for Adapter $1 PD Slot No $2 Dev ID $3 Throttle $4 |
||
irAdpSSDThrottlingOccuring | 1.3.6.1.4.1.3582.5.1.4.60.7037 |
Throttling Occuring for Adapter $1 PD Slot No $2 Dev ID $3 Throttle $4 |
||
irAdpPowerThrottlingRemoved | 1.3.6.1.4.1.3582.5.1.4.60.7038 |
Power Throttling is Removed for Adapter $1 Percent Throttle $2 PCISlotAvailPower $3 |
||
irAdpPowerThrottlingOccuring | 1.3.6.1.4.1.3582.5.1.4.60.7039 |
Power Throttling is Occuring for Adapter $1 Percent Throttle $2 PCISlotAvailPower $3 |
||
irAdpDFFTempExceededWarning | 1.3.6.1.4.1.3582.5.1.4.60.7040 |
Adapter $1 Flags $2 SensorOrSlot $3 CurrTemp $4 ThresholdTemp $5 pdID $6 |
||
irAdpDFFTempExceededCritical | 1.3.6.1.4.1.3582.5.1.4.60.7041 |
Adapter $1 Flags $2 SensorOrSlot $3 CurrTemp $4 ThresholdTemp $5 pdID $6 |
||
irVdtBGIAborted | 1.3.6.1.4.1.3582.5.1.4.60.7101 |
BGI aborted on Adapter -$1 VD Target -$2 |
||
irVdtBGICompleted | 1.3.6.1.4.1.3582.5.1.4.60.7102 |
BGI completed on Adapter -$1 VD Target -$2 |
||
irVdtBGIDoneWR | 1.3.6.1.4.1.3582.5.1.4.60.7103 |
BGI completed with uncorrectable errors on Adapter -$1 VD Target -$2 |
||
irVdtBGIFailed | 1.3.6.1.4.1.3582.5.1.4.60.7104 |
BGI failed on Adapter -$1 VD Target -$2 |
||
irVdtBGIStarted | 1.3.6.1.4.1.3582.5.1.4.60.7105 |
BGI started on Adapter -$1 VD Target -$2 |
||
irVdtCCStarted | 1.3.6.1.4.1.3582.5.1.4.60.7107 |
CC started on Adapter -$1 VD Target -$2 |
||
irVdtCCCompleted | 1.3.6.1.4.1.3582.5.1.4.60.7108 |
CC completed on Adapter -$1 VD Target -$2 |
||
irVdtCCFailed | 1.3.6.1.4.1.3582.5.1.4.60.7109 |
CC failed on Adapter -$1 VD Target -$2 |
||
irVdtCCAborted | 1.3.6.1.4.1.3582.5.1.4.60.7110 |
CC aborted on Adapter -$1 VD Target -$2 |
||
irVdtCCCompCor | 1.3.6.1.4.1.3582.5.1.4.60.7111 |
CC completed with correction on Adapter -$1 VD Target -$2 |
||
irVdtInitAborted | 1.3.6.1.4.1.3582.5.1.4.60.7112 |
Initialization aborted on Adapter -$1 VD Target -$2 |
||
irVdtInitFailed | 1.3.6.1.4.1.3582.5.1.4.60.7113 |
Initialization failed on Adapter -$1 VD Target -$2 |
||
irVdtInitCompleted | 1.3.6.1.4.1.3582.5.1.4.60.7114 |
Initialization completed on Adapter -$1 VD Target -$2 |
||
irVdtInitFastStarted | 1.3.6.1.4.1.3582.5.1.4.60.7115 |
Fast Initialization started on Adapter -$1 VD Target -$2 |
||
irVdtInitFullStarted | 1.3.6.1.4.1.3582.5.1.4.60.7116 |
Full Initialization started on Adapter -$1 VD Target -$2 |
||
irVdtReconStarted | 1.3.6.1.4.1.3582.5.1.4.60.7117 |
Reconstructoin started on Adapter -$1 VD Target -$2 |
||
irVdtReconCompleted | 1.3.6.1.4.1.3582.5.1.4.60.7118 |
Reconstruction completed on Adapter -$1 VD Target -$2 |
||
irVdtReconResumed | 1.3.6.1.4.1.3582.5.1.4.60.7119 |
Reconstruction resumed on Adapter -$1 VD Target -$2 |
||
irVdtReconStopped | 1.3.6.1.4.1.3582.5.1.4.60.7120 |
Reconstruction stopped on Adapter -$1 VD Target -$2 |
||
irVdtStateChange | 1.3.6.1.4.1.3582.5.1.4.60.7121 |
VD state changed on Adapter -$1 VD Target -$2 from $3 to $4 |
||
irVdtCreated | 1.3.6.1.4.1.3582.5.1.4.60.7122 |
A new VD created on Adapter -$1 VD Target -$2 |
||
irVdtDeleted | 1.3.6.1.4.1.3582.5.1.4.60.7123 |
A VD deleted on Adapter -$1 VD Target -$2 |
||
irPdtClearAborted | 1.3.6.1.4.1.3582.5.1.4.60.7201 |
PD Clear aborted on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 |
||
irPdtClearFailed | 1.3.6.1.4.1.3582.5.1.4.60.7202 |
PD Clear failed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 |
||
irPdtClearStarted | 1.3.6.1.4.1.3582.5.1.4.60.7203 |
PD Clear started on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 |
||
irPdtClearCompleted | 1.3.6.1.4.1.3582.5.1.4.60.7204 |
PD Clear completed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 |
||
irPdtError | 1.3.6.1.4.1.3582.5.1.4.60.7205 |
Error occurred on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 |
||
irPdtFormatStart | 1.3.6.1.4.1.3582.5.1.4.60.7206 |
PD format started on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 |
||
irPdtFormatCompleted | 1.3.6.1.4.1.3582.5.1.4.60.7207 |
PD format completed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 |
||
irPdtInserted | 1.3.6.1.4.1.3582.5.1.4.60.7208 |
PD inserted on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 |
||
irPdtRblAborted | 1.3.6.1.4.1.3582.5.1.4.60.7209 |
Rebuild aborted on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 |
||
irPdtRblCompleted | 1.3.6.1.4.1.3582.5.1.4.60.7210 |
Rebuild completed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 |
||
irPdtRblFailedBS | 1.3.6.1.4.1.3582.5.1.4.60.7211 |
Rebuild failed(bad source) on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 |
||
irPdtRblFailedBT | 1.3.6.1.4.1.3582.5.1.4.60.7212 |
Rebuild failed(bad target) on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 |
||
irPdtRblStart | 1.3.6.1.4.1.3582.5.1.4.60.7213 |
Rebuild started on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 |
||
irPdtRblResumed | 1.3.6.1.4.1.3582.5.1.4.60.7214 |
Rebuild resumed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 |
||
irPdtRblStartA | 1.3.6.1.4.1.3582.5.1.4.60.7215 |
Rebuild started(auto) on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 |
||
irPdtRemoved | 1.3.6.1.4.1.3582.5.1.4.60.7216 |
PD removed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 |
||
irPdtStateChange | 1.3.6.1.4.1.3582.5.1.4.60.7217 |
PD state changed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 from $5 to $6 |
||
irPdtSENSEAlert | 1.3.6.1.4.1.3582.5.1.4.60.7218 |
An unexpected Sense was detected on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 CDBData -$5 SenseData -$6 |
||
irPdtPredictiveThresholdExceed | 1.3.6.1.4.1.3582.5.1.4.60.7219 |
Predictive Threshold Exceeded on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 |
||
irPdSSDSecurityLocked | 1.3.6.1.4.1.3582.5.1.4.60.7220 |
SSD is in locked state on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 |
||
irPdSSDSecurityUnlocked | 1.3.6.1.4.1.3582.5.1.4.60.7221 |
SSD is in unlocked state on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 |
||
irBbuPresent | 1.3.6.1.4.1.3582.5.1.4.60.7301 |
Battery Present for Adapter %d |
||
irBbuNotPresent | 1.3.6.1.4.1.3582.5.1.4.60.7302 |
Battery Not Present for Adapter $1 |
||
irBbuNewBattery | 1.3.6.1.4.1.3582.5.1.4.60.7303 |
New Battery for Adapter $1 |
||
irBbuReplaced | 1.3.6.1.4.1.3582.5.1.4.60.7304 |
Battery replaced for Adapter $1 |
||
irBbuTempHigh | 1.3.6.1.4.1.3582.5.1.4.60.7305 |
Battery temperature high for Adapter $1 |
||
irBbuVoltageLow | 1.3.6.1.4.1.3582.5.1.4.60.7306 |
Battery voltage low for Adapter $1 |
||
irBbuCharging | 1.3.6.1.4.1.3582.5.1.4.60.7307 |
Battery started charging for Adapter $1 |
||
irBbuDisCharging | 1.3.6.1.4.1.3582.5.1.4.60.7308 |
Battery is discharging for Adapter $1 |
||
irBbuTempNormal | 1.3.6.1.4.1.3582.5.1.4.60.7309 |
Battery temperature is normal for Adapter $1 |
||
irBbuReplace | 1.3.6.1.4.1.3582.5.1.4.60.7310 |
Battery needs replacement, SOH Bad for Adapter $1 |
||
irBbuRelearnStarted | 1.3.6.1.4.1.3582.5.1.4.60.7311 |
Battery relearn started for Adapter $1 |
||
irBbuRelearnProgress | 1.3.6.1.4.1.3582.5.1.4.60.7312 |
Battery relearn in progress for Adapter $1 |
||
irBbuRelearnComplete | 1.3.6.1.4.1.3582.5.1.4.60.7313 |
Battery relearn completed for Adapter $1 |
||
irBbuRelearnTimeout | 1.3.6.1.4.1.3582.5.1.4.60.7314 |
Battery relearn timed out for Adapter $1 |
||
irBbuRelearnPending | 1.3.6.1.4.1.3582.5.1.4.60.7315 |
Battery relearn pending: Battery is under charge for Adapter $1 |
||
irBbuRelearnPostponed | 1.3.6.1.4.1.3582.5.1.4.60.7316 |
Battery relearn postponed for Adapter $1 |
||
irBbuRemoved | 1.3.6.1.4.1.3582.5.1.4.60.7317 |
Battery removed for Adapter $1 |
||
irBbuCapacityLow | 1.3.6.1.4.1.3582.5.1.4.60.7318 |
Current capacity of the battery is below threshold for Adapter $1 |
||
irBbuCapacityAbove | 1.3.6.1.4.1.3582.5.1.4.60.7319 |
Current capacity of the battery is above threshold for Adapter $1 |
||
copyrightInfo | 1.3.6.1.4.1.3582.5.1.8 | |||
copyright | 1.3.6.1.4.1.3582.5.1.8.1 | displaystring | read-only |
LSI LOGIC |