LEFTHAND-NETWORKS-NSM-NOTIFICATION-MIB: View SNMP OID List / Download MIB

VENDOR: LEFTHAND NETWORKS


 Home MIB: LEFTHAND-NETWORKS-NSM-NOTIFICATION-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 lhnNsmNotificationModule 1.3.6.1.4.1.9804.2.1.15
HP StorageWorks P4000 Notifications: Traps(v1) and Informs(v2c)
       lhnNsmNotificationModuleConformance 1.3.6.1.4.1.9804.2.1.15.1
           lhnNsmNotificationModuleCompliances 1.3.6.1.4.1.9804.2.1.15.1.1
               lefthandNetworksNsmNotificationMibCompliance 1.3.6.1.4.1.9804.2.1.15.1.1.1
The compliance statement.
           lhnNsmNotificationModuleGroups 1.3.6.1.4.1.9804.2.1.15.1.2
               lefthandNetworksNsmNotificationGroup 1.3.6.1.4.1.9804.2.1.15.1.2.1
The default group for all NSM Notification objects.
               lefthandNetworksNsmNotificationMibAllNotifications 1.3.6.1.4.1.9804.2.1.15.1.2.2
The default group for all NSM Notification objects.
 lhnNsmDevices 1.3.6.1.4.1.9804.3.1.1
sub-tree for NSM devices
     lhnNsmEvents 1.3.6.1.4.1.9804.3.1.1.0
sub-tree for NSM events
         lhnNsmNotificationGeneric 1.3.6.1.4.1.9804.3.1.1.0.1
A generic system event was generated. The user chose to be notified of this condition via SNMP. A table of messages exists which stores all the notifications issued. This trap will contain the OID referring to the corresponding message stored in this table. Added in SAN/iQ 8.5
         lhnNsmNotificationBackplane 1.3.6.1.4.1.9804.3.1.1.0.2
An event for the system backplane was generated. The user chose to be notified of this condition via SNMP. A table of messages exists which stores all the notifications issued. This trap will contain the OID referring to the corresponding message stored in this table. Added in SAN/iQ 8.5
         lhnNsmNotificationController 1.3.6.1.4.1.9804.3.1.1.0.3
An event for the RAID controller was generated. The user chose to be notified of this condition via SNMP. A table of messages exists which stores all the notifications issued. This trap will contain the OID referring to the corresponding message stored in this table. Added in SAN/iQ 8.5
         lhnNsmNotificationRAID 1.3.6.1.4.1.9804.3.1.1.0.4
An event for the system RAID was generated. The user chose to be notified of this condition via SNMP. A table of messages exists which stores all the notifications issued. This trap will contain the OID referring to the corresponding message stored in this table. Added in SAN/iQ 8.5
         lhnNsmNotificationDisk 1.3.6.1.4.1.9804.3.1.1.0.5
An event for a disk was generated. The user chose to be notified of this condition via SNMP. A table of messages exists which stores all the notifications issued. This trap will contain the OID referring to the corresponding message stored in this table. Added in SAN/iQ 8.5
         lhnNsmNotificationBootDevice 1.3.6.1.4.1.9804.3.1.1.0.6
An event for a boot device was generated. The user chose to be notified of this condition via SNMP. A table of messages exists which stores all the notifications issued. This trap will contain the OID referring to the corresponding message stored in this table. Added in SAN/iQ 8.5
         lhnNsmNotificationFan 1.3.6.1.4.1.9804.3.1.1.0.7
An event for a fan was generated. The user chose to be notified of this condition via SNMP. A table of messages exists which stores all the notifications issued. This trap will contain the OID referring to the corresponding message stored in this table. Added in SAN/iQ 8.5
         lhnNsmNotificationTemperature 1.3.6.1.4.1.9804.3.1.1.0.8
An event for a temperature sensor was generated. The user chose to be notified of this condition via SNMP. A table of messages exists which stores all the notifications issued. This trap will contain the OID referring to the corresponding message stored in this table. Added in SAN/iQ 8.5
         lhnNsmNotificationPowerSupply 1.3.6.1.4.1.9804.3.1.1.0.9
An event for a power supply was generated. The user chose to be notified of this condition via SNMP. A table of messages exists which stores all the notifications issued. This trap will contain the OID referring to the corresponding message stored in this table. Added in SAN/iQ 8.5
         lhnNsmNotificationVoltage 1.3.6.1.4.1.9804.3.1.1.0.10
An event for a voltage sensor was generated. The user chose to be notified of this condition via SNMP. A table of messages exists which stores all the notifications issued. This trap will contain the OID referring to the corresponding message stored in this table. Added in SAN/iQ 8.5
         lhnNsmNotificationNetwork 1.3.6.1.4.1.9804.3.1.1.0.11
An event for the network was generated. The user chose to be notified of this condition via SNMP. A table of messages exists which stores all the notifications issued. This trap will contain the OID referring to the corresponding message stored in this table. Added in SAN/iQ 8.5
         lhnNsmNotificationMemory 1.3.6.1.4.1.9804.3.1.1.0.12
An event for the system memory was generated. The user chose to be notified of this condition via SNMP. A table of messages exists which stores all the notifications issued. This trap will contain the OID referring to the corresponding message stored in this table. Added in SAN/iQ 8.5
         lhnNsmNotificationCPU 1.3.6.1.4.1.9804.3.1.1.0.13
An event for the CPU was generated. The user chose to be notified of this condition via SNMP. A table of messages exists which stores all the notifications issued. This trap will contain the OID referring to the corresponding message stored in this table. Added in SAN/iQ 8.5
         lhnNsmNotificationLogging 1.3.6.1.4.1.9804.3.1.1.0.14
An event for the log partition was generated. The user chose to be notified of this condition via SNMP. A table of messages exists which stores all the notifications issued. This trap will contain the OID referring to the corresponding message stored in this table. Added in SAN/iQ 8.5
         lhnNsmNotificationManagementGroup 1.3.6.1.4.1.9804.3.1.1.0.15
An event for the management group was generated. The user chose to be notified of this condition via SNMP. A table of messages exists which stores all the notifications issued. This trap will contain the OID referring to the corresponding message stored in this table. Added in SAN/iQ 8.5
         lhnNsmNotificationRemoteManagementGroup 1.3.6.1.4.1.9804.3.1.1.0.16
An event for a remote management group was generated. The user chose to be notified of this condition via SNMP. A table of messages exists which stores all the notifications issued. This trap will contain the OID referring to the corresponding message stored in this table. Added in SAN/iQ 8.5
         lhnNsmNotificationCluster 1.3.6.1.4.1.9804.3.1.1.0.17
An event for the cluster was generated. The user chose to be notified of this condition via SNMP. A table of messages exists which stores all the notifications issued. This trap will contain the OID referring to the corresponding message stored in this table. Added in SAN/iQ 8.5
         lhnNsmNotificationStorageServer 1.3.6.1.4.1.9804.3.1.1.0.18
An event for the storage server was generated. The user chose to be notified of this condition via SNMP. A table of messages exists which stores all the notifications issued. This trap will contain the OID referring to the corresponding message stored in this table. Added in SAN/iQ 8.5
         lhnNsmNotificationRemoteCopy 1.3.6.1.4.1.9804.3.1.1.0.19
An event for a remote copy operation was generated. The user chose to be notified of this condition via SNMP. A table of messages exists which stores all the notifications issued. This trap will contain the OID referring to the corresponding message stored in this table. Added in SAN/iQ 8.5
         lhnNsmNotificationVolume 1.3.6.1.4.1.9804.3.1.1.0.20
An event for a volume was generated. The user chose to be notified of this condition via SNMP. A table of messages exists which stores all the notifications issued. This trap will contain the OID referring to the corresponding message stored in this table. Added in SAN/iQ 8.5
         lhnNsmNotificationSnapshot 1.3.6.1.4.1.9804.3.1.1.0.21
An event for a snapshot was generated. The user chose to be notified of this condition via SNMP. A table of messages exists which stores all the notifications issued. This trap will contain the OID referring to the corresponding message stored in this table. Added in SAN/iQ 8.5
               notificationOldMessageCount 1.3.6.1.4.1.9804.3.1.1.2.13.1 integer32 read-only
number of notification messages Used by SAN/iQ 8.1 and earlier. Obsolete in SAN/iQ 8.5. Marked as current to increase compatability with some SNMP clients.
               notificationOldMessageTable 1.3.6.1.4.1.9804.3.1.1.2.13.2 no-access
A table of notification messages for the NSM. The number of entries is given by notificationMessageCount. Used by SAN/iQ 8.1 and earlier. Obsolete in SAN/iQ 8.5. Marked as current to increase compatability with some SNMP clients.
                   notificationOldMessageEntry 1.3.6.1.4.1.9804.3.1.1.2.13.2.1 no-access
row of notification message parameters Used by SAN/iQ 8.1 and earlier. Obsolete in SAN/iQ 8.5. Marked as current to increase compatability with some SNMP clients.
                       notificationIndex 1.3.6.1.4.1.9804.3.1.1.2.13.2.1.1 unsigned32 no-access
notification message index Used by SAN/iQ 8.1 and earlier. Obsolete in SAN/iQ 8.5. Marked as current to increase compatability with some SNMP clients.
                       notificationMessage 1.3.6.1.4.1.9804.3.1.1.2.13.2.1.2 displaystring read-only
notification message contents Used by SAN/iQ 8.1 and earlier. Obsolete in SAN/iQ 8.5. Marked as current to increase compatability with some SNMP clients.
                       notificationTime 1.3.6.1.4.1.9804.3.1.1.2.13.2.1.3 dateandtime read-only
time notification occurred Used by SAN/iQ 8.1 and earlier. Obsolete in SAN/iQ 8.5. Marked as current to increase compatability with some SNMP clients.
               notificationMessageCount 1.3.6.1.4.1.9804.3.1.1.2.15.1 integer32 read-only
The number of notification messages available in the history.
               notificationMessageTable 1.3.6.1.4.1.9804.3.1.1.2.15.2 no-access
A table of the last 100 notifications for the NSM. The number of entries is given by messageNotificationCount.
                   notificationMessageEntry 1.3.6.1.4.1.9804.3.1.1.2.15.2.1 no-access
A row of notification message information. The information contained in each row is dependant on the trap type and the event that caused the trap. Not all NotificationMessageEntry objects will have values.
                       notificationMessageIndex 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.1 unsigned32 no-access
The index for the notificationMessageTable table.
                       message 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.2 displaystring read-only
The notification message.
                       messageTime 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.3 dateandtime read-only
The time the notification was sent.
                       eventID 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.4 displaystring read-only
The event ID in symbolic format.
                       severity 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.5 integer read-only
The event severity. Enumeration: 'info': 2, 'critical': 0, 'warning': 1.
                       hostname 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.6 displaystring read-only
The NSM hostname.
                       primaryIP 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.7 displaystring read-only
The primary IP address.
                       mac 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.8 displaystring read-only
The MAC address of the primary IP address.
                       serialNumber 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.9 displaystring read-only
The chassis serial number.
                       modelName 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.10 displaystring read-only
The system model name.
                       productName 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.11 displaystring read-only
The OEM product name.
                       productID 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.12 displaystring read-only
The OEM product ID.
                       hpim 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.13 truthvalue read-only
HP Insight Manager SNMP agent installed on NSM
                       softwareVersion 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.14 displaystring read-only
The SAN/iQ software version
                       managementGroupVersion 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.15 displaystring read-only
The management group version.
                       managementGroupSerialNumber 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.16 displaystring read-only
The management group serial number.
                       managementGroup 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.17 displaystring read-only
The management group name.
                       cluster 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.18 displaystring read-only
The cluster name.
                       site 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.19 displaystring read-only
The site the cluster is in.
                       componentName 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.20 displaystring read-only
The component name.
                       systemName 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.21 displaystring read-only
The system hostname.
                       logicalName 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.22 displaystring read-only
The logical name for the component.
                       componentState 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.23 displaystring read-only
The component state.
                       componentModel 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.24 displaystring read-only
The component model.
                       componentSerialNumber 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.25 displaystring read-only
The component serial number.
                       componentFirmwareVersion 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.26 displaystring read-only
The component firmware version.
                       componentHardwareVersion 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.27 displaystring read-only
The component hardware version.
                       driverVersion 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.28 displaystring read-only
The driver version.
                       biosVersion 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.29 displaystring read-only
The BIOS version.
                       raidConfiguration 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.30 displaystring read-only
The RAID configuration.
                       diskInterface 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.31 displaystring read-only
The disk interface type.
                       diskCapacity 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.32 integer32 read-only
The disk capacity.
                       raidState 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.33 displaystring read-only
The RAID state.
                       parityInitStatus 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.34 displaystring read-only
The RAID Parity Initialization status.
                       healthState 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.35 displaystring read-only
The disk health state.
                       bbuState 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.36 displaystring read-only
The BBU state.
                       cacheState 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.37 displaystring read-only
The cache state.
                       linkState 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.38 displaystring read-only
The link state.
                       vipState 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.39 displaystring read-only
The cluster VIP state.
                       maintenanceMode 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.40 displaystring read-only
The management group maintenance mode.
                       minFanSpeed 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.41 integer32 read-only
The minimal fan speed.
                       fanSpeed 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.42 gauge32 read-only
The fan speed.
                       highTemperatureLimit 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.43 integer32 read-only
The high temperature limit.
                       temperatureState 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.44 displaystring read-only
The component temperature state.
                       temperature 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.45 gauge32 read-only
The component temperature.
                       highVoltageLimit 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.46 integer32 read-only
The high voltage limit.
                       lowVoltageLimit 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.47 integer32 read-only
The low voltage limit.
                       voltage 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.48 gauge32 read-only
The voltage.
                       utilization 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.49 gauge32 read-only
The rescource utilization.
                       latency 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.50 gauge32 read-only
The storage server latency.
                       memoryUtilization 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.51 gauge32 read-only
The memory utilization.
                       memoryConfig 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.52 integer32 read-only
The system memory configuration.
                       cpuUtilization 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.53 gauge32 read-only
The CPU utilization.
                       cpuConfig 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.54 integer32 read-only
The number of CPU cores.
                       diskSpeed 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.55 displaystring read-only
The disk interface speed.
                       licenseState 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.56 displaystring read-only
The feature license state.
                       utilizationState 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.57 displaystring read-only
The utilization state.
                       latencyState 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.58 displaystring read-only
The storage server latency state.
                       serverVIPAddress 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.59 displaystring read-only
The VIP address.
                       serverVIPState 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.60 displaystring read-only
The VIP state.
                       replicationState 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.61 displaystring read-only
The volume/snapshot replication state.
                       snapshotState 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.62 displaystring read-only
The snapshot state.
                       snapshotSchedState 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.63 displaystring read-only
The snapshot schedule state.
         userNotification 1.3.6.1.4.1.9804.3.1.1.3.1
A system event was generated. The user chose to be notified of this condition via SNMP. A table of messages exists which stores all the notifications issued. This trap will contain the OID referring to the corresponding message stored in this table. Used by SAN/iQ 8.1 and earlier. Obsolete in SAN/iQ 8.5. Marked as current to increase compatability with some SNMP clients.