Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 juniDosProtectionPlatformMIB 1.3.6.1.4.1.4874.2.2.81
The DOS Protection MIB for the Juniper E-Series product family. This MIB contains managed objects for the DOS Protection application, which are platform specific. Management objects are provided to control and monitor the DOS protection application.
       juniDosProtectionPlatformTraps 1.3.6.1.4.1.4874.2.2.81.0
           juniDosProtectionPlatformScfdsTraps 1.3.6.1.4.1.4874.2.2.81.0.0
               juniDosProtectionScfdsSuspiciousControlFlow 1.3.6.1.4.1.4874.2.2.81.0.0.1
This trap will be generated when a control flow becomes suspicious.
               juniDosProtectionScfdsNonSuspiciousControlFlow 1.3.6.1.4.1.4874.2.2.81.0.0.2
This trap will be generated when a control flow becomes no longer suspicious
               juniDosProtectionScfdsSuspiciousControlFlowGroup 1.3.6.1.4.1.4874.2.2.81.0.0.3
This trap will be generated when a control flow that represents a group becomes suspicious.
               juniDosProtectionScfdsNonSuspiciousControlFlowGroup 1.3.6.1.4.1.4874.2.2.81.0.0.4
This trap will be generated when a control flow that represents a group becomes no longer suspicious.
               juniDosProtectionScfdsTableFull 1.3.6.1.4.1.4874.2.2.81.0.0.5
This trap will be generated when the suspicious flow control table becomes full on a slot.
               juniDosProtectionScfdsTableNotFull 1.3.6.1.4.1.4874.2.2.81.0.0.6
This trap will be generated when the suspicious flow control table is no longer full on a slot.
               juniDosProtectionScfdsGroupingInUse 1.3.6.1.4.1.4874.2.2.81.0.0.7
This trap will be generated when the suspicious flow control system begins to group flow controls on a slot, due to the suspicious flow control table being full.
               juniDosProtectionScfdsSuspiciousProtocol 1.3.6.1.4.1.4874.2.2.81.0.0.8
This trap will be generated when a control protocol becomes suspicious on a slot, and therefore the suspicious control flow system begins to watch flows of this control protocol type.
               juniDosProtectionScfdsNonSuspiciousProtocol 1.3.6.1.4.1.4874.2.2.81.0.0.9
This trap will be generated when a control protocol becomes no longer suspicious on a slot, and therefore the suspicious control flow system will no longer watch flows of this control protocol type.
               juniDosProtectionScfdsSuspiciousPriority 1.3.6.1.4.1.4874.2.2.81.0.0.10
This trap will be generated when a control priority becomes suspicious on a slot.
               juniDosProtectionScfdsNonSuspiciousPriority 1.3.6.1.4.1.4874.2.2.81.0.0.11
This trap will be generated when a control priority becomes no longer suspicious on a slot.
               juniDosProtectionScfdsSuspiciousControlFlowMac 1.3.6.1.4.1.4874.2.2.81.0.0.12
This trap will be generated when a control flow becomes suspicious.
               juniDosProtectionScfdsNonSuspiciousControlFlowMac 1.3.6.1.4.1.4874.2.2.81.0.0.13
This trap will be generated when a control flow becomes no longer suspicious
       juniDosProtectionPlatformObjects 1.3.6.1.4.1.4874.2.2.81.1
           juniDosProtectionPlatformScfdsGroup 1.3.6.1.4.1.4874.2.2.81.1.1
               juniDosProtectionScfdsSlotProtocolTable 1.3.6.1.4.1.4874.2.2.81.1.1.1 no-access
The information for the DOS protection control protocols for a specific slot.
                   juniDosProtectionScfdsSlotProtocolEntry 1.3.6.1.4.1.4874.2.2.81.1.1.1.1 no-access
The information for an individual control protocol on a specific slot.
                       juniDosProtectionScfdsSlotProtocolSlot 1.3.6.1.4.1.4874.2.2.81.1.1.1.1.1 unsigned32 no-access
The slot value for the entry.
                       juniDosProtectionScfdsSlotProtocolIndex 1.3.6.1.4.1.4874.2.2.81.1.1.1.1.2 junidosprotectionprotocoltype no-access
The control protocol value for the entry.
                       juniDosProtectionScfdsSlotProtocolState 1.3.6.1.4.1.4874.2.2.81.1.1.1.1.3 junidosprotectionprotocolstate read-only
The current state of the protocol. This object will return inTrouble(2) if the specific slot referenced is reporting that the protocol is currently being watched for suspicious flows. If the module is not reporting that this protocol is being watched this object will return ok(1). A protocol is in trouble for a slot when the sum of the rate of all flows for the protocol is over the limit for that protocol.
                       juniDosProtectionScfdsSlotProtocolTransitions 1.3.6.1.4.1.4874.2.2.81.1.1.1.1.4 counter32 read-only
The number of transitions to 'inTrouble' that this control protocol has made for this slot.
               juniDosProtectionScfdsSlotFlowTable 1.3.6.1.4.1.4874.2.2.81.1.1.2 no-access
Information about suspicious control flows.
                   juniDosProtectionScfdsSlotFlowEntry 1.3.6.1.4.1.4874.2.2.81.1.1.2.1 no-access
Information about a suspicious control flow.
                       juniDosProtectionScfdsSlotFlowSlot 1.3.6.1.4.1.4874.2.2.81.1.1.2.1.1 unsigned32 no-access
The slot value for the flow.
                       juniDosProtectionScfdsSlotFlowIfIndex 1.3.6.1.4.1.4874.2.2.81.1.1.2.1.2 interfaceindex no-access
The ifIndex value for the flow. For group flows, this value will be zero.
                       juniDosProtectionScfdsSlotFlowGroupId 1.3.6.1.4.1.4874.2.2.81.1.1.2.1.3 unsigned32 no-access
The group id for the flow. The group id will be zero for an individual flow. It is non-zero when the entry represents a group of flows.
                       juniDosProtectionScfdsSlotFlowProtocol 1.3.6.1.4.1.4874.2.2.81.1.1.2.1.4 junidosprotectionprotocoltype no-access
The control protocol for the flow.
                       juniDosProtectionScfdsSlotFlowRate 1.3.6.1.4.1.4874.2.2.81.1.1.2.1.5 unsigned32 read-only
The current rate in packets per second for the flow.
                       juniDosProtectionScfdsSlotFlowPeakRate 1.3.6.1.4.1.4874.2.2.81.1.1.2.1.6 unsigned32 read-only
The peak rate in packets per second for the flow.
                       juniDosProtectionScfdsSlotFlowTimeFlagged 1.3.6.1.4.1.4874.2.2.81.1.1.2.1.7 unsigned32 read-only
The sysUpTime value for the time when the flow was determined to be suspicious.
                       juniDosProtectionScfdsSlotFlowIngressSlot 1.3.6.1.4.1.4874.2.2.81.1.1.2.1.8 integer32 read-only
For control flow that are monitored on the egress processor in the forwarding path, this value will indicate the possible ingress slot for data stream that is possibly causing this suspicious flow control. This object will report -1 when it is undefined
                       juniDosProtectionScfdsSlotFlowGroup 1.3.6.1.4.1.4874.2.2.81.1.1.2.1.9 truthvalue read-only
Indicates whether the flow is a group flow or not. A value of true(1) indicates that the flow represents a group of flows. A value of false(2) indicates that the flow is an individual flow.
                       juniDosProtectionScfdsSlotFlowClearEntry 1.3.6.1.4.1.4874.2.2.81.1.1.2.1.10 integer read-write
When set to clear(1), the suspicious control flow is removed from the suspicious control flow table. When set to ok(0), there is no effect and the suspicious control flow is unchanged. When read, always returns a value of ok(0). Enumeration: 'clear': 1, 'ok': 0.
               juniDosProtectionScfdsSlotTable 1.3.6.1.4.1.4874.2.2.81.1.1.3 no-access
The suspicious control flow information for each slot.
                   juniDosProtectionScfdsSlotEntry 1.3.6.1.4.1.4874.2.2.81.1.1.3.1 no-access
The information for a specific slot.
                       juniDosProtectionScfdsSlotSlot 1.3.6.1.4.1.4874.2.2.81.1.1.3.1.1 unsigned32 no-access
The slot value for this entry.
                       juniDosProtectionScfdsSlotClearAll 1.3.6.1.4.1.4874.2.2.81.1.1.3.1.2 integer read-write
When set to clear(1), the suspicious control flow detection system is cleared for this slot. When set to ok(0), there is no effect and the suspicious control flow detection system is unchanged. By clearing the suspicious control flow detection system all flows on the slot are removed from the suspicious flow table. When read, always returns a value of ok(0). Enumeration: 'clear': 1, 'ok': 0.
                       juniDosProtectionScfdsSlotDiscontinuityTime 1.3.6.1.4.1.4874.2.2.81.1.1.3.1.3 unsigned32 read-only
The sysUpTime at which the counters were re-adjusted due to slot restart.
                       juniDosProtectionScfdsSlotTableOverflowState 1.3.6.1.4.1.4874.2.2.81.1.1.3.1.4 junidosprotectionscfdstableoverflowstate read-only
Indicates whether this slot is under a resource shortage situation. A value of notOverflowingOrGrouping(1) indicates that there is no resource shortage on the slot. A value of grouping(2) or overflowing(3) indicates that this module is suffering from a resource shortage and has acted according to the state of the juniDosProtectionScfdsGlobalGrouping object.
                       juniDosProtectionScfdsSlotCurrentSuspiciousFlows 1.3.6.1.4.1.4874.2.2.81.1.1.3.1.5 counter32 read-only
The number of flows currently marked as suspicious for this slot.
                       juniDosProtectionScfdsSlotNumberSuspiciousFlows 1.3.6.1.4.1.4874.2.2.81.1.1.3.1.6 counter32 read-only
The number of suspicious flows seen on this slot, since slot restart
                       juniDosProtectionScfdsSlotNumberSuspiciousFlowGroups 1.3.6.1.4.1.4874.2.2.81.1.1.3.1.7 counter32 read-only
The number of suspicius flow groups seen on this slot since slot restart.
                       juniDosProtectionScfdsSlotCurrentSuspiciousFlowGroups 1.3.6.1.4.1.4874.2.2.81.1.1.3.1.8 counter32 read-only
The number of flows currently falsely considered suspicious for this slot.
                       juniDosProtectionScfdsSlotCurrentFalseNegativeFlows 1.3.6.1.4.1.4874.2.2.81.1.1.3.1.9 counter32 read-only
The number of flows currently falsely considered suspicious on this slot.
                       juniDosProtectionScfdsSlotNumberFalseNegativeFlows 1.3.6.1.4.1.4874.2.2.81.1.1.3.1.10 counter32 read-only
The number of suspicious flows seen on this slot, since this slot restart.
                       juniDosProtectionScfdsSlotOverflows 1.3.6.1.4.1.4874.2.2.81.1.1.3.1.11 counter32 read-only
The number of times this slot has had a table overflow.
               juniDosProtectionScfdsSlotFlowMacTable 1.3.6.1.4.1.4874.2.2.81.1.1.4 no-access
Information about suspicious control flows.
                   juniDosProtectionScfdsSlotFlowMacEntry 1.3.6.1.4.1.4874.2.2.81.1.1.4.1 no-access
Information about a suspicious control flow.
                       juniDosProtectionScfdsSlotFlowMacSlot 1.3.6.1.4.1.4874.2.2.81.1.1.4.1.1 unsigned32 no-access
The slot value for the flow.
                       juniDosProtectionScfdsSlotFlowMacIfIndex 1.3.6.1.4.1.4874.2.2.81.1.1.4.1.2 interfaceindex no-access
The ifIndex value for the flow. For group flows, this value will be zero.
                       juniDosProtectionScfdsSlotFlowMacGroupId 1.3.6.1.4.1.4874.2.2.81.1.1.4.1.3 unsigned32 no-access
The group id for the flow. The group id will be zero for an individual flow. It is non-zero when the entry represents a group of flows.
                       juniDosProtectionScfdsSlotFlowMacProtocol 1.3.6.1.4.1.4874.2.2.81.1.1.4.1.4 junidosprotectionprotocoltype no-access
The control protocol for the flow.
                       juniDosProtectionScfdsSlotFlowMacSrcMac 1.3.6.1.4.1.4874.2.2.81.1.1.4.1.5 macaddress no-access
The source MAC address for the flow. A null source MAC address indicates that no source physical address was available.
                       juniDosProtectionScfdsSlotFlowMacRate 1.3.6.1.4.1.4874.2.2.81.1.1.4.1.6 unsigned32 read-only
The current rate in packets per second for the flow.
                       juniDosProtectionScfdsSlotFlowMacPeakRate 1.3.6.1.4.1.4874.2.2.81.1.1.4.1.7 unsigned32 read-only
The peak rate in packets per second for the flow.
                       juniDosProtectionScfdsSlotFlowMacTimeFlagged 1.3.6.1.4.1.4874.2.2.81.1.1.4.1.8 unsigned32 read-only
The sysUpTime value for the time when the flow was determined to be suspicious.
                       juniDosProtectionScfdsSlotFlowMacIngressSlot 1.3.6.1.4.1.4874.2.2.81.1.1.4.1.9 integer32 read-only
For control flow that are monitored on the egress processor in the forwarding path, this value will indicate the possible ingress slot for data stream that is possibly causing this suspicious flow control. This object will report -1 when it is undefined
                       juniDosProtectionScfdsSlotFlowMacGroup 1.3.6.1.4.1.4874.2.2.81.1.1.4.1.10 truthvalue read-only
Indicates whether the flow is a group flow or not. A value of true(1) indicates that the flow represents a group of flows. A value of false(0) indicates that the flow is an individual flow.
                       juniDosProtectionScfdsSlotFlowMacClearEntry 1.3.6.1.4.1.4874.2.2.81.1.1.4.1.11 integer read-write
When set to clear(1), the suspicious control flow is removed from the suspicious control flow table. When set to ok(0), there is no effect and the suspicious control flow is unchanged. When read, always returns a value of ok(0). Enumeration: 'clear': 1, 'ok': 0.
           juniDosProtectionPlatformDpgGroup 1.3.6.1.4.1.4874.2.2.81.1.2
               juniDosProtectionDpgSlotRateTable 1.3.6.1.4.1.4874.2.2.81.1.2.1 no-access
This table provides information about the calculated minimum rates (as well as the maximum rates) for each dos-protection-group control protocol for each line module.
                   juniDosProtectionDpgSlotRateEntry 1.3.6.1.4.1.4874.2.2.81.1.2.1.1 no-access
The rates for an individual dos-protection-group on an line module for a control protocol.
                       juniDosProtectionDpgSlotRateSlot 1.3.6.1.4.1.4874.2.2.81.1.2.1.1.1 unsigned32 no-access
The slot value for this entry.
                       juniDosProtectionDpgSlotRateDpgName 1.3.6.1.4.1.4874.2.2.81.1.2.1.1.2 displaystring no-access
The dos-protection-group name for this entry.
                       juniDosProtectionDpgSlotRateProtocol 1.3.6.1.4.1.4874.2.2.81.1.2.1.1.3 junidosprotectionprotocoltype no-access
The control protocol for this entry.
                       juniDosProtectionDpgSlotRateMinRate 1.3.6.1.4.1.4874.2.2.81.1.2.1.1.4 unsigned32 read-only
The minimum rate for this control protocol on this slot for this dos-protection-group. This value is calculated based on the priority rate and oversubscription as well as the control protocol weight
                       juniDosProtectionDpgSlotRateMaxRate 1.3.6.1.4.1.4874.2.2.81.1.2.1.1.5 unsigned32 read-only
The maximum rate for this protocol on this slot for this dos-protection-group. This is equivalent to the configured rate for the dos-protection-group
                       juniDosProtectionDpgSlotRateMinBurst 1.3.6.1.4.1.4874.2.2.81.1.2.1.1.6 unsigned32 read-only
The minimum burst for this control protocol on this slot for this dos-protection-group. This value is calculated based on the priority burst and oversubscription as well as the control protocol weight
                       juniDosProtectionDpgSlotRateMaxBurst 1.3.6.1.4.1.4874.2.2.81.1.2.1.1.7 unsigned32 read-only
The maximum burst for this protocol on this slot for this dos-protection-group. This is equivalent to the configured burst for the dos-protection-group
       juniDosProtectionPlatformTrapControl 1.3.6.1.4.1.4874.2.2.81.2
           juniDosProtectionScfdsSlot 1.3.6.1.4.1.4874.2.2.81.2.1 unsigned32 no-access
The slot value.
           juniDosProtectionPriority 1.3.6.1.4.1.4874.2.2.81.2.2 junidosprotectionprioritytype no-access
The control priority value.
           juniDosProtectionProtocol 1.3.6.1.4.1.4874.2.2.81.2.3 junidosprotectionprotocoltype no-access
The control protocol value.
           juniDosProtectionIfIndex 1.3.6.1.4.1.4874.2.2.81.2.4 interfaceindex no-access
The ifIndex value.
           juniDosProtectionGroupId 1.3.6.1.4.1.4874.2.2.81.2.5 unsigned32 no-access
The group id value.
           juniDosProtectionSrcPhysAddr 1.3.6.1.4.1.4874.2.2.81.2.6 macaddress no-access
The source physical MAC address.
           juniDosProtectionScfdsFlowRate 1.3.6.1.4.1.4874.2.2.81.2.7 unsigned32 no-access
The flow rate at the creation time.
       juniDosProtectionPlatformMIBConformance 1.3.6.1.4.1.4874.2.2.81.4
           juniDosProtectionPlatformMIBCompliances 1.3.6.1.4.1.4874.2.2.81.4.1
               juniDosProtectionCompliance 1.3.6.1.4.1.4874.2.2.81.4.1.1
The compliance statement for entities which implement the Juniper Dos Protection Platform specific MIB. Obsoleted with the addition of dos-protection groups.
               juniDosProtectionCompliance2 1.3.6.1.4.1.4874.2.2.81.4.1.2
The compliance statement for entities which implement the Juniper Dos Protection Platform specific MIB.
           juniDosProtectionPlatformMIBGroups 1.3.6.1.4.1.4874.2.2.81.4.2
               juniDosProtectionGroup 1.3.6.1.4.1.4874.2.2.81.4.2.1
A collection of objects providing management of platform specific aspects of the DOS protection application in a Juniper product. This became obsolete with the addition of MAC address in the flow table and the addition of dos-protection-groups.
               juniDosProtectionNotificationGroup 1.3.6.1.4.1.4874.2.2.81.4.2.2
Collection of objects for DOS protection application notifications in a Juniper product.This became obsolete with the addition of MAC address in flow traps.
               juniDosProtectionGroup1 1.3.6.1.4.1.4874.2.2.81.4.2.3
A collection of objects providing management of platform specific aspects of the DOS protection application in a Juniper product.
               juniDosProtectionNotificationGroup1 1.3.6.1.4.1.4874.2.2.81.4.2.4
Collection of objects for DOS protection application notifications in a Juniper product.