IOMEGANAS-MIB: View SNMP OID List / Download MIB
VENDOR: LENOVOEMC LTD
Home | MIB: IOMEGANAS-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
org | 1.3 | |||
dod | 1.3.6 | |||
internet | 1.3.6.1 | |||
private | 1.3.6.1.4 | |||
enterprises | 1.3.6.1.4.1 | |||
lenovoemc | 1.3.6.1.4.1.11369 |
MIB for Iomega NAS |
||
iomegaNAS | 1.3.6.1.4.1.11369.10 | |||
iomegaNASInfo | 1.3.6.1.4.1.11369.10.1 | |||
deviceDescr | 1.3.6.1.4.1.11369.10.1.1 | displaystring | read-only |
Description of this device. |
deviceName | 1.3.6.1.4.1.11369.10.1.2 | displaystring | read-only |
Iomega NAS host name. |
netConfig | 1.3.6.1.4.1.11369.10.1.3 | |||
dns0 | 1.3.6.1.4.1.11369.10.1.3.1 | ipaddress | read-only |
The first DNS server |
dns1 | 1.3.6.1.4.1.11369.10.1.3.2 | ipaddress | read-only |
Backup DNS server |
wins0 | 1.3.6.1.4.1.11369.10.1.3.3 | ipaddress | read-only |
The first wins server |
wins1 | 1.3.6.1.4.1.11369.10.1.3.4 | ipaddress | read-only |
Backup wins server |
systemPerformance | 1.3.6.1.4.1.11369.10.2 | |||
ioTable | 1.3.6.1.4.1.11369.10.2.1 | no-access |
A table of disk I/O performance. |
|
1.3.6.1.4.1.11369.10.2.1.1 | no-access |
An entry of one disk I/O performance. |
||
ioIndex | 1.3.6.1.4.1.11369.10.2.1.1.1 | integer32 | no-access |
ioIndex |
diskName | 1.3.6.1.4.1.11369.10.2.1.1.2 | octet string | read-only |
Disk names such as sda and so on |
ioMgrs | 1.3.6.1.4.1.11369.10.2.1.1.3 | octet string | read-only |
Read merges per second. |
ioMgws | 1.3.6.1.4.1.11369.10.2.1.1.4 | octet string | read-only |
Write merges per second. |
ioReqrs | 1.3.6.1.4.1.11369.10.2.1.1.5 | octet string | read-only |
Read io requests per second. |
ioReqws | 1.3.6.1.4.1.11369.10.2.1.1.6 | octet string | read-only |
Write io requests per second. |
ioKbrs | 1.3.6.1.4.1.11369.10.2.1.1.7 | octet string | read-only |
Kilobytes read per second. |
ioKbws | 1.3.6.1.4.1.11369.10.2.1.1.8 | octet string | read-only |
Kilobytes written per second. |
ioAvgQueue | 1.3.6.1.4.1.11369.10.2.1.1.9 | octet string | read-only |
Average queue length. |
ioAvgWait | 1.3.6.1.4.1.11369.10.2.1.1.10 | octet string | read-only |
Average waiting time (queue + service) |
ioAvgSvc | 1.3.6.1.4.1.11369.10.2.1.1.11 | octet string | read-only |
Average service time at disk. |
ioAvgUtil | 1.3.6.1.4.1.11369.10.2.1.1.12 | octet string | read-only |
Average disk utilization. |
ioCpuTime | 1.3.6.1.4.1.11369.10.2.1.1.13 | octet string | read-only |
Percentage of CPU time during which I/O requests were issued to the device. |
iomegaNASFunctionStatus | 1.3.6.1.4.1.11369.10.3 | |||
bkupTable | 1.3.6.1.4.1.11369.10.3.1 | no-access |
A table of backup status. |
|
1.3.6.1.4.1.11369.10.3.1.1 | no-access |
An entry of backup status. |
||
bkupIndex | 1.3.6.1.4.1.11369.10.3.1.1.1 | integer32 | no-access |
Record backup status |
bkupClient | 1.3.6.1.4.1.11369.10.3.1.1.2 | octet string | read-only |
Client Name |
bkupltStatus | 1.3.6.1.4.1.11369.10.3.1.1.3 | octet string | read-only |
Last backup status |
bkupTotalSpace | 1.3.6.1.4.1.11369.10.3.1.1.4 | octet string | read-only |
Total space |
remoteAccess | 1.3.6.1.4.1.11369.10.3.2 | |||
raEnabled | 1.3.6.1.4.1.11369.10.3.2.1 | integer32 | read-only |
Whether RA is enabled 0 Disable 1 Enable |
conTable | 1.3.6.1.4.1.11369.10.3.3 | no-access |
Table for connected client count |
|
1.3.6.1.4.1.11369.10.3.3.1 | no-access |
Entry for connected client count |
||
conIndex | 1.3.6.1.4.1.11369.10.3.3.1.1 | integer32 | no-access |
Index for entry |
conCount | 1.3.6.1.4.1.11369.10.3.3.1.2 | integer32 | read-only |
Connected client count for a given protocol |
conProtocol | 1.3.6.1.4.1.11369.10.3.3.1.3 | displaystring | read-only |
Protocol used by this kind of clients |
mediaService | 1.3.6.1.4.1.11369.10.3.4 | |||
mediaServiceEnabled | 1.3.6.1.4.1.11369.10.3.4.1 | integer32 | read-only |
Whether media service is enabled 0 disable 1 enable |
iomegaNASStorage | 1.3.6.1.4.1.11369.10.4 | |||
raidStatus | 1.3.6.1.4.1.11369.10.4.1 | octet string | read-only |
Description of raid status. There are five different status: NORMAL REBUILDING DEGRADED REBUILDFS FAULTED |
raidLevel | 1.3.6.1.4.1.11369.10.4.2 | integer32 | read-only |
Raid level(5/10) |
diskTable | 1.3.6.1.4.1.11369.10.4.3 | no-access |
The table of disks that build the RAID. |
|
1.3.6.1.4.1.11369.10.4.3.1 | no-access |
An entry of one disk. |
||
diskIndex | 1.3.6.1.4.1.11369.10.4.3.1.1 | integer32 | no-access |
Index of disk entry |
diskID | 1.3.6.1.4.1.11369.10.4.3.1.2 | octet string | read-only |
ID of disk in array |
diskSize | 1.3.6.1.4.1.11369.10.4.3.1.3 | octet string | read-only |
Capacity of disk |
diskStatus | 1.3.6.1.4.1.11369.10.4.3.1.4 | octet string | read-only |
Status of Disk. There are four status: NORMAL FOREIGN FAULTED MISSING |
iomegaNASDevice | 1.3.6.1.4.1.11369.10.5 | |||
usbTable | 1.3.6.1.4.1.11369.10.5.1 | no-access |
Table of connected usb devices. |
|
1.3.6.1.4.1.11369.10.5.1.1 | no-access |
Entry for connected USB device |
||
usbIndex | 1.3.6.1.4.1.11369.10.5.1.1.1 | integer32 | no-access |
Index for entry in the table |
usbManufacture | 1.3.6.1.4.1.11369.10.5.1.1.2 | displaystring | read-only |
Manufucture of the device |
usbModel | 1.3.6.1.4.1.11369.10.5.1.1.3 | displaystring | read-only |
Model of the USB device |
usbType | 1.3.6.1.4.1.11369.10.5.1.1.4 | integer32 | read-only |
USB device type(such UPS(3), PTP(6), printer(7) and so on) |
iomegaNASSensor | 1.3.6.1.4.1.11369.10.6 | |||
fanTable | 1.3.6.1.4.1.11369.10.6.1 | no-access |
Table for fan sensors |
|
1.3.6.1.4.1.11369.10.6.1.1 | no-access |
Entry for fan sensor |
||
fanIndex | 1.3.6.1.4.1.11369.10.6.1.1.1 | integer32 | no-access |
Index for the entry |
fanName | 1.3.6.1.4.1.11369.10.6.1.1.2 | displaystring | read-only |
Name of the fan sensor |
fanValue | 1.3.6.1.4.1.11369.10.6.1.1.3 | gauge32 | read-only |
Rotation speed of the fan in RPM |
tempTable | 1.3.6.1.4.1.11369.10.6.2 | no-access |
Table for temperature sensor |
|
1.3.6.1.4.1.11369.10.6.2.1 | no-access |
Entry for temperature sensor |
||
tempIndex | 1.3.6.1.4.1.11369.10.6.2.1.1 | integer32 | no-access |
Index for entry |
tempName | 1.3.6.1.4.1.11369.10.6.2.1.2 | displaystring | read-only |
Name of the temperature sensor |
tempValue | 1.3.6.1.4.1.11369.10.6.2.1.3 | gauge32 | read-only |
The temperature of the sensor in mC. |
voltTable | 1.3.6.1.4.1.11369.10.6.3 | no-access |
Table for volt sensor |
|
1.3.6.1.4.1.11369.10.6.3.1 | no-access |
Entry for volt sensor |
||
voltIndex | 1.3.6.1.4.1.11369.10.6.3.1.1 | integer32 | no-access |
Index for the entry |
voltName | 1.3.6.1.4.1.11369.10.6.3.1.2 | displaystring | read-only |
Name of the volt sensor |
voltValue | 1.3.6.1.4.1.11369.10.6.3.1.3 | gauge32 | read-only |
The voltage in mV |
iomegaNASEvent | 1.3.6.1.4.1.11369.10.7 | |||
eventID | 1.3.6.1.4.1.11369.10.7.1 | displaystring | read-only |
ID of the event |
eventText | 1.3.6.1.4.1.11369.10.7.2 | displaystring | read-only |
Description of the event. |
iomegaNASNotifications | 1.3.6.1.4.1.11369.10.8 | |||
iomegaNASNotificationError | 1.3.6.1.4.1.11369.10.8.1 |
An Error EventMonitorTrap is generated in response to a user-specified event. Details can be found in Variables data. |
||
iomegaNASNotificationWarn | 1.3.6.1.4.1.11369.10.8.2 |
A Warning EventMonitorTrap is generated in response to a user-specified event. Details can be found in Variables data. |
||
iomegaNASNotificationInfo | 1.3.6.1.4.1.11369.10.8.3 |
An Informational EventMonitorTrap is generated in response to a user-specified event. Details can be found in Variables data. |