IMCO-LS110-MIB: View SNMP OID List / Download MIB
VENDOR: AN-D.CZ
Home | MIB: IMCO-LS110-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
mib_AN_Dcz_SDS | 1.3.6.1.4.1.33283 |
The MIB module to describe PSMSmicro version of SDS. |
||
sdsxpublic | 1.3.6.1.4.1.33283.1 | |||
sdsBIGandSTSW | 1.3.6.1.4.1.33283.1.30 | |||
sdsOptoInput | 1.3.6.1.4.1.33283.1.30.2 | |||
opto1 | 1.3.6.1.4.1.33283.1.30.2.1 | integer | read-only |
Current OPTO1 binary input status. Enumeration: 'activeSignalPresent': 0, 'noSignal': 32768. |
opto2 | 1.3.6.1.4.1.33283.1.30.2.2 | integer | read-only |
Current OPTO2 binary input status. Enumeration: 'activeSignalPresent': 0, 'noSignal': 1. |
opto3 | 1.3.6.1.4.1.33283.1.30.2.3 | integer | read-only |
Current Mains (OPTO3) binary input status. Enumeration: 'activeSignalPresent': 0, 'noSignal': 2. |
sdsOutputRelays | 1.3.6.1.4.1.33283.1.30.3 | |||
sdsOutputRelay1 | 1.3.6.1.4.1.33283.1.30.3.1 | |||
sdsRE1state | 1.3.6.1.4.1.33283.1.30.3.1.1 | integer | read-write |
Current RELAY 1 output status. Enumeration: 'off': 0, 'activated': 255. |
sdsOutputRelay2 | 1.3.6.1.4.1.33283.1.30.3.2 | |||
sdsRE2state | 1.3.6.1.4.1.33283.1.30.3.2.1 | integer | read-write |
Current RELAY 2 output status. Enumeration: 'off': 0, 'activated': 255. |
sdsOutputRelay3 | 1.3.6.1.4.1.33283.1.30.3.3 | |||
sdsRE3state | 1.3.6.1.4.1.33283.1.30.3.3.1 | integer | read-write |
Current RELAY 3 output status. Enumeration: 'off': 0, 'activated': 255. |
sdsADCinputs | 1.3.6.1.4.1.33283.1.30.5 | |||
sdsADCitem0 | 1.3.6.1.4.1.33283.1.30.5.1 | |||
sdsTempSensValue | 1.3.6.1.4.1.33283.1.30.5.1.3 | gauge32 | read-only |
Temperature Sensor (C) multiplied by 100. |
sdsTempSensName | 1.3.6.1.4.1.33283.1.30.5.1.4 | octet string | read-only |
User name for the analog temperature sensor. |
sdsADCvalues | 1.3.6.1.4.1.33283.1.30.7 | |||
sdsMaximumLoad | 1.3.6.1.4.1.33283.1.30.7.2 | integer32 | read-only |
Maximum Load (W) multiplied by 10. |
sdsAlarmText | 1.3.6.1.4.1.33283.1.30.7.3 | octet string | read-only |
SDS Alarm Text. |
sdsOutputVoltage1 | 1.3.6.1.4.1.33283.1.30.7.4 | integer32 | read-only |
Output voltage U1 (V) multiplied by 100. |
sdsOutputVoltage2 | 1.3.6.1.4.1.33283.1.30.7.5 | integer32 | read-only |
Output voltage U2 (V) multiplied by 100. |
sdsOutputCurrent | 1.3.6.1.4.1.33283.1.30.7.6 | integer32 | read-only |
Output current I (A) multiplied by 10. |
sdsBatteryCapacity | 1.3.6.1.4.1.33283.1.30.7.7 | integer32 | read-only |
Battery Capacity (%) multiplied by 10. |
sdsLoad | 1.3.6.1.4.1.33283.1.30.7.8 | integer32 | read-only |
Load (%) multiplied by 10. |
sdsCapTestTime | 1.3.6.1.4.1.33283.1.30.7.9 | integer32 | read-only |
Time (min) of last Capacity Test. |
sdsGeneralInfoEntry | 1.3.6.1.4.1.33283.1.30.8 | |||
sdsManufacturer | 1.3.6.1.4.1.33283.1.30.8.80 | octet string | read-only |
Manufacturer of the device. |
sdsModel | 1.3.6.1.4.1.33283.1.30.8.81 | octet string | read-only |
Model (type) of the device. |
sdsName | 1.3.6.1.4.1.33283.1.30.8.82 | octet string | read-only |
Name/Location of the device. |
sdsSerialNumber | 1.3.6.1.4.1.33283.1.30.8.83 | octet string | read-only |
Serial number of the device. |
sdsSoftware | 1.3.6.1.4.1.33283.1.30.8.84 | octet string | read-only |
Software version of the device. |
opto1_trap | 1.3.6.1.4.1.332830.100 |
TRAP: optical input 1 status. |
||
opto2_trap | 1.3.6.1.4.1.332830.101 |
TRAP: optical input 2 status. |
||
opto3_trap | 1.3.6.1.4.1.332830.102 |
TRAP: optical input 3 status. |
||
sdsRE1state_trap | 1.3.6.1.4.1.332830.150 |
TRAP: Current RELAY 1 output status. |
||
sdsRE2state_trap | 1.3.6.1.4.1.332830.153 |
TRAP: Current RELAY 2 output status. |
||
sdsTempSensValue_trap | 1.3.6.1.4.1.332830.222 |
TRAP: Temperature Sensor (C) multiplied by 100. |
||
sdsTempSensName_trap | 1.3.6.1.4.1.332830.223 |
TRAP: User name for analog temperature sensor. |
||
sdsMaximumLoad_trap | 1.3.6.1.4.1.332830.401 |
TRAP: SDS Maximum Load-trap. |
||
sdsAlarmText_trap | 1.3.6.1.4.1.332830.402 |
TRAP: SDS Alarm Text. |
||
sdsOutputVoltage1_trap | 1.3.6.1.4.1.332830.403 |
TRAP: SDS Output Voltage1-trap. |
||
sdsOutputVoltage2_trap | 1.3.6.1.4.1.332830.404 |
TRAP: SDS Outpur Voltage2-trap. |
||
sdsOutputCurrent_trap | 1.3.6.1.4.1.332830.405 |
TRAP: SDS Output current-trap. |
||
sdsBatteryCapacity_trap | 1.3.6.1.4.1.332830.406 |
TRAP: SDS Battery Capacity-trap. |
||
sdsLoad_trap | 1.3.6.1.4.1.332830.407 |
TRAP: SDS Load-trap. |
||
sdsCapTestTime_trap | 1.3.6.1.4.1.332830.408 |
TRAP: SDS CapTestTime-trap. |