ICT-SINE-WAVE-INVERTER-MIB: View SNMP OID List / Download MIB
VENDOR: INNOVATIVE CIRCUIT TECHNOLOGY
Home | MIB: ICT-SINE-WAVE-INVERTER-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
ictPower | 1.3.6.1.4.1.39145 | |||
inverter | 1.3.6.1.4.1.39145.12 | |||
deviceModel | 1.3.6.1.4.1.39145.12.1 | displaystring | read-only |
Model Number |
deviceName | 1.3.6.1.4.1.39145.12.2 | displaystring | read-only |
Site Name |
deviceHardware | 1.3.6.1.4.1.39145.12.3 | integer | read-only |
Hardware Version |
deviceFirmware | 1.3.6.1.4.1.39145.12.4 | displaystring | read-only |
Firmware Version |
deviceMacAddress | 1.3.6.1.4.1.39145.12.5 | displaystring | read-only |
MAC Address |
batteryVoltage | 1.3.6.1.4.1.39145.12.6 | displaystring | read-only |
Battery Voltage (VDC) |
inverterVoltage | 1.3.6.1.4.1.39145.12.7 | displaystring | read-only |
Inverter Output Voltage (VAC) |
inverterPower | 1.3.6.1.4.1.39145.12.8 | displaystring | read-only |
Inverter Output Power (%) |
inverterStatus | 1.3.6.1.4.1.39145.12.9 | integer | read-only |
Inverter Output Status ('1' indicates the Inverter Output is ENABLED, and '2' indicates the Inverter Output is DISABLED) Enumeration: 'disabled': 2, 'enabled': 1. |
inverterControl | 1.3.6.1.4.1.39145.12.10 | integer | read-write |
Inverter Output Control (set to '1' to ENABLE the Inverter Output if no alarms are active, set to '2' to DISABLE the Inverter Output) Enumeration: 'disabled': 2, 'enabled': 1. |
transferRelayStatus | 1.3.6.1.4.1.39145.12.11 | integer | read-only |
Transfer Relay Status ('1' indicates the Output is connected to the INVERTER, and '2' indicates the Output is connected to the GRID) Enumeration: 'inverter': 1, 'grid': 2. |
undervoltageAlarmTrap | 1.3.6.1.4.1.39145.120.101 |
Trap generated when the Battery Input Undervoltage Alarm is triggered |
||
overvoltageAlarmTrap | 1.3.6.1.4.1.39145.120.102 |
Trap generated when the Battery Input Overvoltage Alarm is triggered |
||
overtemperatureAlarmTrap | 1.3.6.1.4.1.39145.120.103 |
Trap generated when the Overtemperature Alarm is triggered |
||
outputFaultAlarmTrap | 1.3.6.1.4.1.39145.120.104 |
Trap generated when the Inverter Output Fault Alarm is triggered |
||
systemFaultAlarmTrap | 1.3.6.1.4.1.39145.120.105 |
Trap generated when the System Fault Alarm is triggered |
||
remoteSwitchAlarmTrap | 1.3.6.1.4.1.39145.120.106 |
Trap generated when the Remote Switch accessory is activated |
||
undervoltageAlarmClear | 1.3.6.1.4.1.39145.120.111 |
Trap generated when the Battery Input Undervoltage Alarm is cleared |
||
overvoltageAlarmClear | 1.3.6.1.4.1.39145.120.112 |
Trap generated when the Battery Input Overvoltage Alarm is cleared |
||
overtemperatureAlarmClear | 1.3.6.1.4.1.39145.120.113 |
Trap generated when the Overtemperature Alarm is cleared |
||
outputFaultAlarmClear | 1.3.6.1.4.1.39145.120.114 |
Trap generated when the Inverter Output Fault Alarm is cleared |
||
systemFaultAlarmClear | 1.3.6.1.4.1.39145.120.115 |
Trap generated when the System Fault Alarm is cleared |
||
remoteSwitchAlarmClear | 1.3.6.1.4.1.39145.120.116 |
Trap generated when the Remote Switch accessory is deactivated |
||
inverterPowerTrap | 1.3.6.1.4.1.39145.120.121 |
Trap generated when the Output switches to Inverter (Battery) Power |
||
gridPowerTrap | 1.3.6.1.4.1.39145.120.122 |
Trap generated when the Output switches to Grid Power |