IBOOTPDU-MIB: View SNMP OID List / Download MIB

VENDOR: DATAPROBE INC.


 Home MIB: IBOOTPDU-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 dataprobe 1.3.6.1.4.1.1418
           iBoot_PDU_Agent 1.3.6.1.4.1.1418.6
iBoot-PDU Agent Version 1.1
               device 1.3.6.1.4.1.1418.6.1
                   firmwareVersion 1.3.6.1.4.1.1418.6.1.1 displaystring read-only
                   deviceName 1.3.6.1.4.1.1418.6.1.2 displaystring read-write
This is a 20 character string that contains the name of the iBootBar.
                   deviceFamily 1.3.6.1.4.1.1418.6.1.3 displaystring read-only
                   deviceModelName 1.3.6.1.4.1.1418.6.1.4 displaystring read-only
                   deviceConnector 1.3.6.1.4.1.1418.6.1.5 integer read-only
Enumeration: 'iec': 1, 'nema': 0.
                   deviceNumberOfOutlets 1.3.6.1.4.1.1418.6.1.6 integer32 read-only
                   deviceNumberOfLineCords 1.3.6.1.4.1.1418.6.1.7 integer read-only
Enumeration: 'two': 1, 'one': 0.
                   deviceMaxCurrent 1.3.6.1.4.1.1418.6.1.8 integer32 read-only
                   deviceTemperatureUnit 1.3.6.1.4.1.1418.6.1.9 integer read-write
fahrenheit (0) celsius (1) Enumeration: 'fahrenheit': 0, 'celsius': 1.
                   deviceTimeZone 1.3.6.1.4.1.1418.6.1.10 displaystring read-only
                   deviceCalibrated 1.3.6.1.4.1.1418.6.1.11 integer read-only
Enumeration: 'false': 0, 'true': 1.
                   modemCountryCode 1.3.6.1.4.1.1418.6.1.12 integer32 read-only
                   outletDelayTime 1.3.6.1.4.1.1418.6.1.13 integer32 read-write
                   cloudServiceEnabled 1.3.6.1.4.1.1418.6.1.14 integer read-write
Enumeration: 'false': 0, 'true': 1.
                   cloudServerAddress 1.3.6.1.4.1.1418.6.1.15 displaystring read-write
                   cloudActivationCode 1.3.6.1.4.1.1418.6.1.16 displaystring read-only
                   cloudUUID 1.3.6.1.4.1.1418.6.1.17 displaystring read-only
                   setFactoryDefaults 1.3.6.1.4.1.1418.6.1.18 integer read-write
true(1) false(0) Enumeration: 'false': 0, 'true': 1.
                   rebootSystem 1.3.6.1.4.1.1418.6.1.19 integer read-write
true(1) false(0) Enumeration: 'false': 0, 'true': 1.
                   rebootRequired 1.3.6.1.4.1.1418.6.1.20 integer read-only
Enumeration: 'false': 0, 'true': 1.
               console 1.3.6.1.4.1.1418.6.2
                   serialPortEnabled 1.3.6.1.4.1.1418.6.2.1 integer read-write
Enumeration: 'false': 0, 'true': 1.
                   consoleTimeout 1.3.6.1.4.1.1418.6.2.2 integer32 read-write
                   telnetEnabled 1.3.6.1.4.1.1418.6.2.3 integer read-write
Eanlbe the telnet server. Enumeration: 'false': 0, 'true': 1.
                   telnetPort 1.3.6.1.4.1.1418.6.2.4 integer32 read-write
The port for the telnet server to use.
                   sshEnabled 1.3.6.1.4.1.1418.6.2.5 integer read-write
Enumeration: 'false': 0, 'true': 1.
                   sshPort 1.3.6.1.4.1.1418.6.2.6 integer32 read-write
               network 1.3.6.1.4.1.1418.6.3
                   macAddress 1.3.6.1.4.1.1418.6.3.1 macaddress read-only
                   ipMode 1.3.6.1.4.1.1418.6.3.2 integer read-write
static(0) dhcp(1) Enumeration: 'dhcp': 1, 'static': 0.
                   ipAddress 1.3.6.1.4.1.1418.6.3.3 ipaddress read-write
The IP Address of the device
                   subnetMask 1.3.6.1.4.1.1418.6.3.4 ipaddress read-write
                   gateway 1.3.6.1.4.1.1418.6.3.5 ipaddress read-write
Address of the default gateway
                   dnsServer1 1.3.6.1.4.1.1418.6.3.6 ipaddress read-write
                   dnsServer2 1.3.6.1.4.1.1418.6.3.7 ipaddress read-write
                   sslEnabled 1.3.6.1.4.1.1418.6.3.8 integer read-write
Enable secure sockest layer on the web server. Enumeration: 'false': 0, 'true': 1.
                   sslPort 1.3.6.1.4.1.1418.6.3.9 integer32 read-write
                   webEnabled 1.3.6.1.4.1.1418.6.3.10 integer read-write
Use this variable to enable/disable the web server Enumeration: 'false': 0, 'true': 1.
                   webPort 1.3.6.1.4.1.1418.6.3.11 integer32 read-write
The port number that the web server will use. Changing this var will not take effect until the unit has be reset.
               snmp 1.3.6.1.4.1.1418.6.4
                   snmpEnabled 1.3.6.1.4.1.1418.6.4.1 integer read-write
Enumeration: 'false': 0, 'true': 1.
                   snmpReadCommunity 1.3.6.1.4.1.1418.6.4.2 displaystring read-write
                   snmpWriteCommunity 1.3.6.1.4.1.1418.6.4.3 displaystring read-write
                   snmpManagerTable 1.3.6.1.4.1.1418.6.4.4 no-access
                       snmpManagerEntry 1.3.6.1.4.1.1418.6.4.4.1 no-access
                           snmpManagerIndex 1.3.6.1.4.1.1418.6.4.4.1.1 integer32 read-only
The table index
                           snmpManagerAddress 1.3.6.1.4.1.1418.6.4.4.1.2 displaystring read-write
                           snmpManagerName 1.3.6.1.4.1.1418.6.4.4.1.3 displaystring read-write
                           snmpTrapCommunity 1.3.6.1.4.1.1418.6.4.4.1.4 displaystring read-write
               outletTable 1.3.6.1.4.1.1418.6.5 no-access
                   outletEntry 1.3.6.1.4.1.1418.6.5.1 no-access
                       outletIndex 1.3.6.1.4.1.1418.6.5.1.1 integer32 read-only
                       outletName 1.3.6.1.4.1.1418.6.5.1.2 displaystring read-write
The name of the outlet up to 20 characters
                       outletInitialState 1.3.6.1.4.1.1418.6.5.1.3 integer read-write
Enumeration: 'on': 1, 'off': 0, 'last': 2.
                       outletCycleTime 1.3.6.1.4.1.1418.6.5.1.4 integer32 read-write
                       outletControl 1.3.6.1.4.1.1418.6.5.1.5 integer read-write
Use this a a write only variable. It is used to change the outlets status Enumeration: 'on': 1, 'off': 0, 'cycle': 2.
                       outletStatus 1.3.6.1.4.1.1418.6.5.1.6 integer read-only
Enumeration: 'on': 1, 'cycle': 2, 'pend-on': 4, 'off': 0, 'reboot': 3.
                       outletActualStatus 1.3.6.1.4.1.1418.6.5.1.7 integer read-only
Status of the physical outlet Enumeration: 'on': 1, 'off': 0.
               sensors 1.3.6.1.4.1.1418.6.6
                   voltageLC1 1.3.6.1.4.1.1418.6.6.1 integer32 read-only
                   currentLC1 1.3.6.1.4.1.1418.6.6.2 integer32 read-only
                   voltageLC2 1.3.6.1.4.1.1418.6.6.3 integer32 read-only
                   currentLC2 1.3.6.1.4.1.1418.6.6.4 integer32 read-only
                   temperature1 1.3.6.1.4.1.1418.6.6.5 integer32 read-only
                   temperature2 1.3.6.1.4.1.1418.6.6.6 integer32 read-only
               notifications 1.3.6.1.4.1.1418.6.7
                   outletChange 1.3.6.1.4.1.1418.6.7.1
This trap is sent when ever an outlet changes state. It contains the name of the outlet.