IBM2260-OPT-MIB: View SNMP OID List / Download MIB

VENDOR: CODEX


 Home MIB: IBM2260-OPT-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 codex 1.3.6.1.4.1.449
         cdxProductSpecific 1.3.6.1.4.1.449.2
             cdx6500 1.3.6.1.4.1.449.2.1
                 cdx6500Configuration 1.3.6.1.4.1.449.2.1.2
                     cdx6500CfgProtocolGroup 1.3.6.1.4.1.449.2.1.2.1
                         cdx6500PCTPortProtocolGroup 1.3.6.1.4.1.449.2.1.2.1.1
                             cdx6500PPCTIBM2260PortTable 1.3.6.1.4.1.449.2.1.2.1.1.20 no-access
A list of IBM2260 Port configuration entries.
                                   cdx6500PPCTIBM2260PortEntry 1.3.6.1.4.1.449.2.1.2.1.1.20.1 no-access
An IBM2260 Configuration Table entry. Each entry contains the configuration parameters for a single IBM2260 port.
                                       cdx6500IBM2260CfgPortNumber 1.3.6.1.4.1.449.2.1.2.1.1.20.1.1 integer read-only
The port number corresponding to this port.
                                       cdx6500IBM2260CfgPadType 1.3.6.1.4.1.449.2.1.2.1.1.20.1.2 integer read-only
Indicates whether the port is functioning as a Terminal PAD (TPAD) or a Host PAD (HPAD). Enumeration: 'hpad': 2, 'tpad': 1.
                                       cdx6500IBM2260CfgPortSpeed 1.3.6.1.4.1.449.2.1.2.1.1.20.1.3 integer read-only
This is the speed of the port in bits per second, when using internal clocking. Enumeration: 'speed4800': 14, 'speed19200': 16, 'speed9600': 15, 'speed1800': 8, 'speed1200': 4, 'speed2400': 13, 'speed7200': 99.
                                       cdx6500IBM2260CfgConnType 1.3.6.1.4.1.449.2.1.2.1.1.20.1.4 integer read-only
Specify the control signal handshake required for a connection to be made to this port: simp - simple, no control signals required. simpa - CTS follows RTS, but no control signals required. Enumeration: 'simpa': 16, 'simp': 1.
                                       cdx6500IBM2260CfgNumDevice 1.3.6.1.4.1.449.2.1.2.1.1.20.1.5 integer read-only
Specifies the number of IBM2260 stations on this line.
                                       cdx6500IBM2260CfgServiceTimer 1.3.6.1.4.1.449.2.1.2.1.1.20.1.6 integer read-only
The Service Timer specifies the interval of time in seconds between periodic servicing. Such servicing includes intervals between attempts to establish network connections, intervals between attempts in TPAD to poll terminals that previously failed to respond, and in HPAD this timer is also used to detect host inactivity (i.e. when the host stops polling the station(s)).
                                       cdx6500IBM2260CfgThreshCtr 1.3.6.1.4.1.449.2.1.2.1.1.20.1.7 integer read-only
Indicates number of consecutive errors that can occur before a station is considered down.
                                       cdx6500IBM2260CfgRespTimeout 1.3.6.1.4.1.449.2.1.2.1.1.20.1.8 integer read-only
Specifies the amount of time in msec the PAD allows a terminal, printer or host to respond. As a result, the TPAD may re-transmit the previous message or abort the current procedure. The HPAD aborts the current procedure as though EOT was received, allowing this HPAD station to disconnect it's SVC if the host malfunctions. An HPAD with a response timeout shorter than the hosts ability to respond may result in Inbound Errors.
                                       cdx6500IBM2260CfgPortSubAddr 1.3.6.1.4.1.449.2.1.2.1.1.20.1.9 displaystring read-only
Calls addressed to this node and with this subaddress will be routed to this port.
                                       cdx6500IBM2260CfgPortOpt 1.3.6.1.4.1.449.2.1.2.1.1.20.1.10 displaystring read-only
Select options on this IBM2260 port as follows: NONE - No option specified ORG - Originate calls from this port ACK - DSP End-to-End Acknowledgements are to be used Any combination of above specified by summing (e.g. ORG+ACK).
                                       cdx6500IBM2260CfgRestConnDest 1.3.6.1.4.1.449.2.1.2.1.1.20.1.11 displaystring read-only
All calls originating from this port will be routed to the destination specified in this parameter, irrespective of route selection table entries. For example, to route calls to port 1, use P1. To route calls to port 2, station 4, use P2S4. Blank this field to disable this function.
                                       cdx6500IBM2260CfgBillRec 1.3.6.1.4.1.449.2.1.2.1.1.20.1.12 integer read-only
This controls whether billing (accounting) records will be created for calls on this port. Enumeration: 'on': 2, 'off': 1.
                                       cdx6500IBM2260CfgElectricalInterfaceType 1.3.6.1.4.1.449.2.1.2.1.1.20.1.13 integer read-only
Specify the Electrical Interface Type: V.24 - V.24 Electrical Interface Type V.35 - V.35 Electrical Interface Type V.36 - V.36 Electrical Interface Type X.21 - X.21 Electrical Interface Type Note: Changing this parameter requires manual settings on SWITCH1: Interface SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 V.24 ON ON ON ON ON OFF OFF OFF V.35,V.36,X.21 OFF OFF OFF OFF OFF ON ON ON Enumeration: 'x21': 4, 'v35': 2, 'v36': 3, 'v24': 1.
                                       cdx6500IBM2260CfgV24ElectricalInterfaceOption 1.3.6.1.4.1.449.2.1.2.1.1.20.1.14 integer read-only
Specify the Pin 22 option: RI - V.24 uses Pin 22 for Ring Indicator output signal TM - V.24 uses Pin 22 for Test Mode input signal Enumeration: 'tm': 2, 'ri': 1.
                                       cdx6500IBM2260CfgHighSpeedElectricalInterfaceOption 1.3.6.1.4.1.449.2.1.2.1.1.20.1.15 integer read-only
Specify the cable type: NONE - V.35/V.36/X.21 DCE with straight through cable XOVER - V.35/V.36/X.21 DCE with crossover adapter cable Enumeration: 'none': 1, 'xover': 2.
                         cdx6500PCTStationProtocolGroup 1.3.6.1.4.1.449.2.1.2.1.3
                             cdx6500SPCTIBM2260StationTable 1.3.6.1.4.1.449.2.1.2.1.3.6 no-access
All of the configuration parameters relevant to the IBM2260 Station table.
                                 cdx6500SPCTIBM2260StationEntry 1.3.6.1.4.1.449.2.1.2.1.3.6.1 no-access
A row of IBM2260 station configuration parameters.
                                     cdx6500IBM2260sCfgPortNum 1.3.6.1.4.1.449.2.1.2.1.3.6.1.1 integer read-only
Port number.
                                     cdx6500IBM2260sCfgStationNum 1.3.6.1.4.1.449.2.1.2.1.3.6.1.2 integer read-only
Station number.
                                     cdx6500IBM2260sType 1.3.6.1.4.1.449.2.1.2.1.3.6.1.3 integer read-only
single - configures a single station addressable by the ADDR1-ADDR2 address pair. group - configures a group of stations addressable by the ADDR1 address character, but ADDR2 is assumed to be 40H, 41H, 42H and 43H. This type is intended for support of DataTroll devices. NOTE: `group' Station should not be used when the BSC3270-IBM2260 protocol Interoperation is being used. Enumeration: 'single': 1, 'group': 2.
                                     cdx6500IBM2260sStationAddr1 1.3.6.1.4.1.449.2.1.2.1.3.6.1.4 displaystring read-only
This is the first byte of this Station's address. The Station address consists of two hexadecimal digits. The valid range for a digit is: 20-7F;
                                     cdx6500IBM2260sStationAddr2 1.3.6.1.4.1.449.2.1.2.1.3.6.1.5 displaystring read-only
This is the second byte of this Station's address. The Station address consists of two hexadecimal digits. The valid range for a digit is: 20-7F
                                     cdx6500IBM2260sCallMnem 1.3.6.1.4.1.449.2.1.2.1.3.6.1.6 displaystring read-only
This mnemonic name is used if this port is configured for originating connection requests.
                                     cdx6500IBM2260sStationEnable 1.3.6.1.4.1.449.2.1.2.1.3.6.1.7 integer read-only
This parameter is used to disable/enable a station. Enumeration: 'yes': 2, 'no': 1.
                 cdx6500Statistics 1.3.6.1.4.1.449.2.1.3
                     cdx6500StatProtocolGroup 1.3.6.1.4.1.449.2.1.3.1
                         cdx6500PSTPortProtocolGroup 1.3.6.1.4.1.449.2.1.3.1.1
                             cdx6500PPSTIBM2260PortTable 1.3.6.1.4.1.449.2.1.3.1.1.19 no-access
A list of IBM2260 Port statistics.
                                   cdx6500PPSTIBM2260PortEntry 1.3.6.1.4.1.449.2.1.3.1.1.19.1 no-access
An IBM2260 Statistics Table entry. Each entry contains the statistics for a single IBM2260 port.
                                       cdx6500IBM2260StatPortNumber 1.3.6.1.4.1.449.2.1.3.1.1.19.1.1 integer read-only
Physical port number
                                       cdx6500IBM2260StatPortStatus 1.3.6.1.4.1.449.2.1.3.1.1.19.1.2 displaystring read-only
Operational Status of the port. The different operational statuses are: UP : At least 1 station is responding to polls. DOWN : None of the stations are responding to polls. DISABLED : The port is disabled by the user.
                                       cdx6500IBM2260StatPortState 1.3.6.1.4.1.449.2.1.3.1.1.19.1.3 displaystring read-only
Current State of this port.
                                       cdx6500IBM2260StatPortSpeed 1.3.6.1.4.1.449.2.1.3.1.1.19.1.4 integer read-only
The measured port speed in bits per second. Enumeration: 'speed4800': 4, 'speed19200': 7, 'speed9600': 6, 'speed1800': 2, 'speed1200': 1, 'speed2400': 3, 'speed7200': 5.
                                       cdx6500IBM2260StatPortUtilin 1.3.6.1.4.1.449.2.1.3.1.1.19.1.5 integer read-only
The amount of the port's bandwidth that is being utilized; because IBM2260 is a half-duplex protocol the utilization is calculated as the sum of the receive and transmit utilization.
                                       cdx6500IBM2260StatPortUtilOut 1.3.6.1.4.1.449.2.1.3.1.1.19.1.6 integer read-only
The amount of the port's bandwidth that is being utilized; because IBM2260 is a half-duplex protocol the utilization is calculated as the sum of the receive and transmit utilization.
                                       cdx6500IBM2260StatParityErrors 1.3.6.1.4.1.449.2.1.3.1.1.19.1.7 integer read-only
The number of character parity errors counted by the I/O driver.
                                       cdx6500IBM2260StatOverrunErrors 1.3.6.1.4.1.449.2.1.3.1.1.19.1.8 integer read-only
The number of received character overruns counted by the I/O driver.
                                       cdx6500IBM2260StatFramingErrors 1.3.6.1.4.1.449.2.1.3.1.1.19.1.9 integer read-only
The number of asynchronous chracters received which violated the character framing of start and stop bits. Note, this statistic is only valid if the port is configured for ASYNC line interface.
                                       cdx6500IBM2260StatBCCErrors 1.3.6.1.4.1.449.2.1.3.1.1.19.1.10 integer read-only
The number of BCC errors counted by the I/O driver.
                                       cdx6500IBM2260StatNoResponse 1.3.6.1.4.1.449.2.1.3.1.1.19.1.11 integer read-only
The number of times the response timer has expired.
                                       cdx6500IBM2260StatCharInTotal 1.3.6.1.4.1.449.2.1.3.1.1.19.1.12 integer read-only
Total number of chracters received to present.
                                       cdx6500IBM2260StatCharOutTotal 1.3.6.1.4.1.449.2.1.3.1.1.19.1.13 integer read-only
Total number of chracters transmitted to present.
                                       cdx6500IBM2260StatCharInSecond 1.3.6.1.4.1.449.2.1.3.1.1.19.1.14 integer read-only
Average number of characters received to present.
                                       cdx6500IBM2260StatCharOutSecond 1.3.6.1.4.1.449.2.1.3.1.1.19.1.15 integer read-only
Average number of characters transmitted to present.
                                       cdx6500IBM2260StatPosAckIn 1.3.6.1.4.1.449.2.1.3.1.1.19.1.16 integer read-only
Number of ACKs received.
                                       cdx6500IBM2260StatPosAckOut 1.3.6.1.4.1.449.2.1.3.1.1.19.1.17 integer read-only
Number of ACKs transmitted.
                                       cdx6500IBM2260StatNegAckIn 1.3.6.1.4.1.449.2.1.3.1.1.19.1.18 integer read-only
Number of NAKs received.
                                       cdx6500IBM2260StatNegAckOut 1.3.6.1.4.1.449.2.1.3.1.1.19.1.19 integer read-only
Number of NAKs transmitted.
                                       cdx6500IBM2260StatMsgRetran 1.3.6.1.4.1.449.2.1.3.1.1.19.1.20 integer read-only
Number of messages retransmitted due to NAKs or timeouts to present.
                         cdx6500PSTStationProtocolGroup 1.3.6.1.4.1.449.2.1.3.1.3
                 cdx6500Controls 1.3.6.1.4.1.449.2.1.4